| INSTRUCTIONS   SDMM8 Manual Meter and   SDMP8 Preset Meter   333492B   EN   For metered dispense of petroleum-based lubricants, oils and 50:50 antifreeze/water mix   fluids only.   For professional use only.   Maximum Working Pressure: 1500 psi (10 MPa, 103 bar)   Important Safety Instructions   Read all warnings and instructions in this   manual. Save these instructions.   Download from Www.Somanuals.com. All Manuals Search And Download.   Models   The following packages include Bare Meter Model 24U957 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   Inlet   Extension Nozzle/Extension Kit Nozzle Parts†   24V044   24V047   24V050   4/16 Liter   4/16 Liter   4/16 Liter   BSPT   BSPT   BSPT   Flex   Rigid   Gear Lube   24V475   255852   255854   255459   255459   255470   The following packages include Bare Meter Model 24U958 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   Inlet   Extension Nozzle/Extension Kit Nozzle Parts†   24V045   24V048   24V051   4/16 Liter   4/16 Liter   4/16 Liter   BSPP   BSPP   BSPP   Flex   Rigid   Gear Lube   24V475   255852   255854   255459   255459   255470   SDMP8 Preset Meters   Bare preset meters do not include a nozzle or extension. Model packages that include a nozzle and extension are   provided on page 4.   Model Number   Model Description   Inlet   24U947*   24U948*   24U949*   24U950*   24U951*   24U952*   24U953*   24U954*   24U955*   60 Quart   60 Quart   60 Quart   60 Gallon   60 Gallon   60 Gallon   60 Liter   NPT   BSPT   BSPP   NPT   BSPT   BSPP   NPT   60 Liter   60 Liter   BSPT   BSPP   *This meter can be used for antifreeze applications with antifreeze nozzle 255855 or 24W306. See page 24 for infor-   mation about these nozzles.   333492B   3 Download from Www.Somanuals.com. All Manuals Search And Download.   Models   SDMP8 Preset Meters with Nozzle and Extension Packages   The following packages include Bare Meter Model 24U947 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V052 60 Quart   Inlet   NPT   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U948 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V053 60 Quart   Inlet   BSPT   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U949 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V054 60 Quart   Inlet   BSPP   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U950 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V055 60 Gallon   Inlet   NPT   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U951 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V056 60 Gallon   Inlet   BSPT   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U952 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V057 60 Gallon   Inlet   BSPP   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U953 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V058 60 Liter   Inlet   NPT   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U954 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V059 60 Liter   Inlet   BSPT   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   The following packages include Bare Meter Model 24U955 and the nozzle and extension kits indicated in the table   below.   Model Number Model Description   24V060 60 Liter   Inlet   Extension Nozzle/Extension Kit Nozzle Parts†   Rigid 24W641 255459   BSPP   4 333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Warnings   Warnings   The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-   tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When   these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific   hazard symbols and warnings not covered in this section may appear throughout the body of this manual where   applicable.   FIRE AND EXPLOSION HAZARD   When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be   aware that flammable fumes can ignite or explode. To help prevent fire and explosion:   • • • • • • • Use equipment only in well ventilated area.   Eliminate all ignition sources, such as cigarettes and portable electric lamps.   Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.   Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.   Ground all equipment in the work area.   Use only grounded hoses.   Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment   until you identify and correct the problem.   • Keep a working fire extinguisher in the work area.   SKIN INJECTION HAZARD   High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This   may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical   treatment.   • • • • Do not point dispensing device at anyone or at any part of the body.   Do not put your hand over the fluid outlet.   Do not stop or deflect leaks with your hand, body, glove, or rag.   Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or   servicing equipment.   + • • Tighten all fluid connections before operating the equipment.   Check hoses and couplings daily. Replace worn or damaged parts immediately.   333492B   5 Download from Www.Somanuals.com. All Manuals Search And Download.   Warnings   EQUIPMENT MISUSE HAZARD   Misuse can cause death or serious injury.   • • Do not operate the unit when fatigued or under the influence of drugs or alcohol.   Do not exceed the maximum working pressure or temperature rating of the lowest rated system   component. See Technical Data in all equipment manuals.   • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all   equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information   about your material, request MSDS from distributor or retailer.   • • • Do not leave the work area while equipment is energized or under pressure.   Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.   Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-   facturer’s replacement parts only.   • Do not alter or modify equipment. Alterations or modifications may void agency approvals and create   safety hazards.   • • • • • • Make sure all equipment is rated and approved for the environment in which you are using it.   Use equipment only for its intended purpose. Call your distributor for information.   Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.   Do not kink or over bend hoses or use hoses to pull equipment.   Keep children and animals away from work area.   Comply with all applicable safety regulations.   PRESSURIZED ALUMINUM PARTS HAZARD   Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical   reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or prop-   erty damage.   • Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or   fluids containing such solvents.   • Many other fluids may contain chemicals that can react with aluminum. Contact your material sup-   plier for compatibility.   PERSONAL PROTECTIVE EQUIPMENT   Wear appropriate protective equipment when in the work area to help prevent serious injury, including   eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is   not limited to:   • • Protective eyewear, and hearing protection.   Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer   6 333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Typical Installation   Typical Installation   A L K R F B D C G P E M J S H N FIG. 1   Key:   A B C D E F Main air supply line   Pump air supply line   Air filter   Air regulator   Bleed-type master air valve (required)   Pump   G H Pump grounding wire (required)   Pressure relief valve (required)   NOTE: The relief pressure cannot exceed the meter’s maximum working pressure   J K L M N P R S Fluid shut off valve   Fluid line   Fluid shut off valve   Hose reel   SDMM8 or SDMP8 meter   Mounting channel   Hose reel fluid inlet kit   Fluid drain valve   333492B   7 Download from Www.Somanuals.com. All Manuals Search And Download.   Installation   Installation   NOTE: The letters used in the following instructions   Grounding   Pressure Relief Procedure   Follow the Pressure Relief Procedure whenever   you see this symbol.   • The equipment must be grounded to reduce the   risk of static sparking. Static sparking can cause   fumes to ignite or explode. Grounding provides   an escape wire for the electric current.   • To prevent electric arcing do not allow the   conductive metal surfaces on the meter to make   contact with any positively charged metal   surface, including (but not limited to), the starter   solenoid terminal, alternator terminal or battery   terminal.   This equipment stays pressurized until pressure is   manually relieved. To help prevent serious injury from   pressurized fluid, such as skin injection, splashing   fluid and moving parts, follow the Pressure Relief   Procedure when you stop spraying and before   cleaning, checking, or servicing the equipment.   Ground all components in the system:   1. Turn off power supply to the pump or close   upstream master air valve (E).   Pump (F): Follow manufacturer’s recommendations.   2. Open all fluid shut off valves (J and L) in the system.   Air and fluid supply lines (A, B, K): Only use electri-   cally conductive hoses. Check electrical resistance of   hoses. If total resistance to ground exceeds 29 meg-   ohms, replace hose immediately.   3. Trigger the meter (N) into a waste container to   relieve pressure.   4. Open fluid drain valves and leave them open until   you are ready to pressurize the system.   Air compressor: Follow manufacturer’s recommenda-   tions.   Fluid supply container: Follow local code.   To maintain grounding continuity when flushing or   relieving pressure: hold a metal part of the meter firmly   to the side of a grounded metal pail, then trigger the   valve.   SDMM8 and SDMP8 Meter (N): When installing the   meter leave at least two threads bare when using thread   sealant. The bare threads ensure a ground is main-   tained.   8 333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Installation   4. Slowly open the fluid shut off valve (J).   Pre-Installation Procedure   5. If you have multiple dispense positions, first flush   the dispense position farthest from the pump and   work your way toward the pump. Slowly open the   fluid shut-off valve (L) at the dispense position.   Flush out a sufficient amount of oil to ensure that the   entire system is clean; then close the valve.   NOTE: The letters used in the following instructions   21.   Installing Meter (FIG. 3)   ) 2. Close all fluid drain valves.   1. If this is a new installation and the first time a meter   is installed, skip step 1.   Installation Procedure   For existing installations, to replace the meter (N):   NOTICE   • If this is a new installation or if the fluid lines are   contaminated, flush the lines before you install the   metered valve. Contaminated lines could cause the   valve to leak.   b. Use two wrenches working in opposite direc-   tions to loosen meter and hose fitting. Remove   meter (N) from hose.   • Never dispense compressed air with meter. Doing   so will damage meter.   N 1 Flushing   NOTE: The meter should not be installed for this proce-   dure.   1. Close the fluid shut-off valve (L) at each dispense   position.   FIG. 3   2. Apply thread sealant to the male threads of the hose   fitting. Leave at least two threads bare when using   thread sealant. The bare threads ensure a ground is   maintained.   2. Make sure:   • • all fluid drain valves are closed,   fluid shut off valve (J) is closed,   3. Thread the meter swivel (1) onto the hose fitting.   Use two wrenches working in opposite directions to   tighten meter securely to hose fitting.   and   • the bleed-type master air valve (E) is open.   NOTE: Make sure you allow sufficient time for the seal-   ant to cure to the manufacturer’s recommendations   before circulating fluid through the system.   3. Place the end of the hose into a container for waste   oil. Secure the hose in the container so it will not   come out during flushing.   10   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Installation   4. Install extension (102) to meter:   d. Wrench tighten extension nut (102a).   5. Install nozzle (101):   completely off tube threads.   NOTE: Do not use PTFE tape or thread sealant on   threads of nozzle (101). This could cause the fitting to   leak.   102   a. Thread nozzle (101) onto extension (102) as   . 102   102a   FIG. 4   101   NOTE: Do not use PTFE tape or thread sealant on   threads of extension (102). This could cause the fitting   to leak.   101a   b. Thread extension (102) into meter housing as   FIG. 7   b. Use an open-end adjustable wrench on flats of   • Only tighten nozzle with wrench on flats of the   nozzle bushing.   102   • Do not disassemble the bushing from noz-   zle. Disassembly will affect performance of the   nozzle.   FIG. 5   c. Align extension (102) with meter housing and   handle. Hand tighten extension nut (102a).   FIG. 6   333492B   11   Download from Www.Somanuals.com. All Manuals Search And Download.   Operation   The totalizer keeps a running total of the amounts dis-   pensed.   Operation   NOTE: The letters used in the following instructions   21.   1. Turn meter pointer (41) counter-clockwise to select   the desired volume.   1. Open fluid shut off valves (J and L).   2. Start pump (F) to pressurize system.   2. Turn automatic twist lock nozzle (101) clockwise to   open nozzle. Insert nozzle into the fluid receptacle   and pull the trigger (12).   3. Adjust the air pressure to the pump motor so the   fluid pressure is no greater than 1500 psi (103.4   bar, 10.34 MPa)   NOTE: The trigger latches automatically. Do not set   trigger to enable meter to dispense when it is unat-   tended.   NOTE: To ensure dispensing accuracy, before begin-   ning dispense, pull trigger to purge all air from the fluid   lines and meter.   The meter shuts off automatically when the set amount   of fluid is dispensed.   4. Continue operation with instructions for Preset Auto-   matic or Manual Shutoff Valve Instructions.   Manual Shutoff Valve   NOTE: Clean strainer (3a) regularly. See Parts, page   21.   NOTICE   SPLASH HAZARD   To avoid costly meter damage, never turn the Manual   Meter pointer (41) backwards (clockwise).   Do not trigger meter when nozzle is closed. Fluid   will build up behind the nozzle. Fluid can leak from   the nozzle and can unexpectedly be expelled when   the nozzle is opened. If the meter is accidentally trig-   gered with the nozzle closed, point the nozzle into a   waste bucket and slowly open the nozzle to relieve   pressure and expel the built up fluid.   41   Preset Automatic Shutoff   NOTE: Clean strainer (3a) regularly. See Parts, page   19.   FIG. 9   NOTICE   The totalizer keeps a running total of the amounts dis-   pensed.   To avoid costly meter damage, never turn the Preset   1. Turn automatic twist lock nozzle (101) counter-   clockwise to open nozzle. Insert nozzle into the fluid   receptacle and pull the trigger (12).   41   2. Watch the meter pointer (41) on the meter dial (37)   move. Release the trigger (12) when the desired   amount of fluid has been dispensed.   3. Turn the meter pointer (41) counter-clockwise to   return it to “0” before dispensing again. See FIG. 9   FIG. 8   12   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Troubleshooting   Troubleshooting   Relieve pressure, page 8, before you check or repair the meter. Be sure all other valves, controls and pump are   operating properly.   Problem   Cause   Solution   2. Remove meter from hose.   3. Clean or replace strainer (3a).   Strainer (3a) is clogged.   4. Install meter to hose (See Installing   5. If the problem remains, contact your   Graco distributor for repair or   replacement.   Pump pressure is low.   Increase pump pressure.   Slow or no fluid flow.   Twist lock nozzle not fully open.   Aim nozzle into bucket. Fully open noz-   zle.   Do not trigger meter when nozzle is   closed! If you do accidentally trigger   the meter with the nozzle closed, point   nozzle into a waste bucket and slowly   open the nozzle to relieve pressure and   expel built up fluid.   Fluid shut-off valve (J or L) is not fully open   (page 9).   Fully open fluid shut-off valve (J or L).   Foreign material is wedged in the meter   housing.   Contact your Graco distributor for repair   or replacement.   Meter leaks from twist lock nozzle.   Twist lock nozzle has a damaged seal.   Replace nozzle. See Step a in Installa-   tion Procedure, page 11.   • It is important to distinguish   between the two causes of this   problem. A new nozzle will NOT   correct a fluid leak caused by a   faulty valve.   Valve has damaged or obstructed seals.   Clean valve assembly or replace.   Poor swivel/hose connection.   Apply PTFE tape (leave a minimum 2   engaged threads uncovered for electri-   cal continuity) or sealant to threads of   hose and tighten the connection. See   Meter leaks from swivel.   Poor swivel/meter housing connection.   Swivel seals have deteriorated and leak.   Torque the fitting to 20-25 ft.-lbs.   Replace swivel.   333492B   13   Download from Www.Somanuals.com. All Manuals Search And Download.   Service   Service   5. Remove seal (18) and piston assembly (19). If the   piston assembly sticks, lightly tap the housing   Cleaning / Repairing the Fluid   Section   NOTE: Do not disassemble the fluid and counting sec-   tions simultaneously. Confirm the fluid section is fully   assembled before removing the counting section.   18   19   2. Close fluid shut off valve (L).   3. Remove nozzle (101) and extension (102).   FIG. 12   6. Insert a screwdriver into the notch of the piston   assembly (19) and pry off the piston cover (19d).   101   102   19d   19   FIG. 10   FIG. 13   4. Turn meter cap (17) counter-clockwise to unscrew   and remove it from the meter housing.   7. Clean the parts (19a-g) and blow them dry.   8. Reassemble the piston assembly (19) and install in   meter.   9. Install cover (17) on meter housing. Torque to 11-14   ft. lbs (14.9-18.9 N•m).   10. Install nozzle and extension assembly (101 and   102).   17   FIG. 11   14   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Service   4. Use a hex wrench to remove the plug setscrew.   SDMM8 Manual Meter Counter   Section Repair   Remove the plug (50), remove the pin (51), spring   Disassembly   50   51   52   NOTE: Do not disassemble the fluid and counting sec-   tions simultaneously. Confirm the fluid section is fully   assembled before removing the counting section.   53   FIG. 16   2. Remove the cover (44), small retaining ring (43),   5. Remove the large retaining clip (38) and then the   44   42   43   38   37   41   FIG. 14   3. Remove the needle pointer (41), springs (39) and   FIG. 17   6. Use a 2 mm hex wrench to remove the gear set-   41   39/40   34   35   33   32   FIG. 15   FIG. 18   333492B   15   Download from Www.Somanuals.com. All Manuals Search And Download.   Service   3. Install the face plate panel (37) and large retaining   38   37   31   FIG. 19   FIG. 22   4. Install the lower pointer (52), spring (53), pin (51)   wrench to tighten the plug setscrew.   Reassembly   1. Install counter assembly (31).   50   51   52   31   53   FIG. 23   5. Install the needle pointer (41), springs (39) and pins   FIG. 20   Use a 2 mm hex wrench to tighten the gear set-   screw (33).   41   39/40   34   35   33   32   FIG. 24   FIG. 21   16   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Service   6. Install small retaining ring (43), pointer pin (41) and   3. Remove the needle pointer (41), springs (39) and   41   44   42   43   39/40   41   FIG. 25   FIG. 27   4. Remove the large retaining clip (38) and then the   SDMP8 Preset Meter Counter   Section Repair   38   37   Disassembly   NOTE: Do not disassemble the fluid and counting sec-   tions simultaneously. Confirm the fluid section is fully   assembled before removing the counting section.   FIG. 28   2. Remove the cover (44), small retaining ring (43),   5. Use a 2 mm hex wrench to remove the gear set-   44   43   34   33   32   FIG. 26   FIG. 29   333492B   17   Download from Www.Somanuals.com. All Manuals Search And Download.   Service   31   3. Install face plate panel (37) and large retaining clip   38   37   FIG. 30   Reassembly   FIG. 33   4. Install the needle pointer (41), springs (39) and pins   31   41   39/40   FIG. 34   FIG. 31   35).   2. Install the gears (32, 34). Use a 2 mm hex wrench to   44   43   34   33   32   FIG. 32   FIG. 35   18   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   SDMM8 Manual Meter Parts   SDMM8 Manual Meter Parts   Models 24U959, 24U960, 24U961, 24U956,   24U957, 24U958   Ref A   Ref B   28   33   44   43   41   See   Ref B   19g   19f   50   35   42   51   34   36   19d   19b   39   40   40   39   19c   38   52   39   40   37   32   16   19a   33   31   19   11   2 See Ref A   2 15   1 1   3a   3b   5 6 7 8 9 10   14   18   46   29   12   13   17   3 14   15   16   49   45   47   2 48   1 2 3 Torque to 7-10 ft lbs (9-13 N.m)   Torque to 15-25 in. lbs (1.7-2.8 N.m)   Torque to 11-14 ft. lbs (14.9-18.9 N.m)   333492B   19   Download from Www.Somanuals.com. All Manuals Search And Download.   SDMM8 Manual Meter Parts   SDMM8 Manual Meter Parts   Models 24U959, 24U960, 24U961, 24U956, 24U957, 24U958   Ref   Part No. Description   GEAR, 10 teeth   Qty   Ref   Part No. Description   Qty   19f   19g   28   1 1 1 1 1 1 2 1 1 1 1 1 SWIVEL   1 GEAR, 21 teeth   238399   model 24U959, 24U956   24V467 KIT, SHAFT   24H383 model 24U960, 24U957   24H382 model 24U961, 24U958   HOUSING, meter   29   106560   PACKING, o-ring   31   24U352 COUNTER   2 3 1 1 32   33†   34   16X595 GEAR, worm-spur   16X589 SCREW, setting M4 x 6   16X588 GEAR. twins, 14-32   16X586 GEAR, 42 teeth   16X491 COVER, protector   DIAL   256164   KIT, strainer, includes 3a   and 3b   3a   3b   5 STRAINER   10   10   1 WASHER, plain   SPRING, compression   35   113493   36   6 15U704 SEAT, valve   1 37   7 15U701 SPRING, secondary   15U700 PLUNGER, trigger lift   16X485 SEAT, valve   1 16X597 models 24U959, 24U960,   24U961   8 1 16X596 models 24U956, 24U957,   24U958   9 1 10   11   12   13   14   15   16   17   18   19   121412   277673   O-RING, pack   ROD, push   1 38   16X498 CLIP, ring   1 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 39†   40†   41†   42†   43†   44†   45   46   47   48   49   50†   51†   52†   53†   16X583 SPRING, inner and outer   16X592 PIN, inner and outer   16X576 NEEDLE, upper   16X584 SPRING, outer, pointer   17B784 RING, retaining   16X575 COVER, needle   15R013 LATCH, lever   15M886 TRIGGER   1 191315   113574   191552   110637   CAM   1 SEAL, o-ring   2 WASHER, flat   SCREW, mach, panhead   2 2 16X493 CAP, housing   1 156633   PACKING, o-ring   1 15R014 SPRING, latch   15R015 LATCH, arm   KIT, piston, includes   19a-19g   1 15R016 LATCH, pin   24V470 QUARTS, models   24U959, 24U960,   24U961   114680   PIN, dowel   16X580 PLUG   24V471 LITERS, models 24U956,   24U957, 24U958   16X582 PIN, outer pointer   16X578 NEEDLE, lower, casting   16X601 SPRING (not shown)   19a   PISTON, chamber   PISTON, oscillating   DIVIDER   1 1 1 1 1 19b   19c   19d   19e    Parts are included in Kit 24V460   † Parts are included in Kit 24V474    Parts are included in Kit 24V473   GEAR, cover   ROLLER (not shown)   20   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   SDMP8 Preset Meter Parts   SDMP8 Preset Meter Parts   Models 24U947, 24U948, 24U949, 24U950, 24U951, 24U952, 24U953, 24U954, 24U955   Ref A   30   Ref B   44   41   19g   19f   See   Ref B   43b   19a   19c   34   42   35   39   19b   40   51   38   39   19d   40   45   50   1 46   1 37   43a   3b   3a   5 32   33   6 19   See Ref A   49   7 47   8 31   48   16   2 15   9 11   10   18   2 3 17   14   52   28   12   13   14   15   16   2 1 2 3 Torque to 7-10 ft lbs (9-13 N.m)   Torque to 15-25 in. lbs (1.7-2.8 N.m)   Torque to 11-14 ft. lbs (14.9-18.9 N.m)   333492B   21   Download from Www.Somanuals.com. All Manuals Search And Download.   SDMP8 Preset Meter Parts   SDMP8 Preset Meter Parts   Models 24U947, 24U948, 24U949, 24U950, 24U951, 24U952, 24U953, 24U954, 24U955   Ref   19b   Part No. Description   PISTON, oscillating   Qty   Ref   Part No. Description   Qty   1 1 1 1 1 1 1 1 1 SWIVEL   19c   19d   19e   19f   19g   28   DIVIDER   PISTON, chamber   ROLLER (not shown)   GEAR, 10 teeth   238399 model 24U947, 24U950,   24U953   24H383 model 24U948, 24U951,   24U954   24H382 model 24U949, 24U952,   24U955   GEAR, 21 teeth   106560 PACKING, o-ring   KIT, shaft   1 1 2 3 HOUSING, meter   1 30   256164 KIT, strainer, includes 3a   and 3b   24V468 models 24U947, 24U948,   24U949, 24U953, 24U954,   24U955   3a   3b   5 STRAINER   1 1 1 WASHER, plain   24V469 models 24U950, 24U951,   24U952   113493 SPRING, compression   15U704 SEAT, valve   15U701 SPRING, secondary   15U700 PLUNGER, trigger lift   16X485 SEAT, valve   121412 O-RING, packing   277673 ROD, push   1 1 1 1 1 1 1 1 2 2 2 1 1 1 1 6 31   COUNTER   7 24U354 model 24U947, 24U948,   24U949   8 24U353 model 24U950, 24U951,   24U952   9 10   11   12   13   14   15   16   17   18   19   24U352 model 24U953, 24U954,   24U955   1 16Y317 TRIGGER   32   ‡ GEAR, worm-spur   16X497 CAM   16X594 models 24U947, 24U948,   24U949, 24U950, 24U951,   24U952   113574 SEAL, o-ring   191552 WASHER, flat   110637 SCREW, mach, panhead   16X494 CAP, housing   156633 PACKING, o-ring    16X593 models 24U953, 24U954,   24U955   1 1 1 33‡   34   16X589 SCREW, setting   16X585 GEAR, 45 teeth   16X490 COVER   KIT, piston, includes   19a-19h   35   24V470 QUARTS, models 24U947,   24U948, 24U949   GALLONS, models   24U950, 24U951, 24U952   24V471 LITERS, models 24U953,   24U954, 24U955   19a   GEAR, cover   1 22   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   SDMP8 Preset Meter Parts   Ref   Part No. Description   Qty   Ref   40   Part No. Description   Qty   1 2 36   16X587 GEAR, twin 11-44 teeth   (not shown) Models   16X581 PIN, inner and outer   pointer   24U947, 24U948, 24U949,   24U953, 24U954, 24U955   1 1 41   42   43   16X577 NEEDLE   16X584 SPRING, outer pointer   RING, retaining   1 16Y999 GEAR, twin 24-44 teeth   (not shown) Models   24U950, 24U951, 24U952   1 1 1 1 1 1 1 1 1 1 1 43a   43b   44   45   46   47   48   16X611   16X588 GEAR. twins, 14-32, (not   shown) Models 24U950,   24U951, 24U952   1 1 1 17B784   16X575 COVER, needle   16X606 BRACKET, valve, trigger   16X607 PIN, screw   16X613 SPRING, lock, pawl   PIN, lock, pawl   17A029 GEAR, 11-42 teeth (not   shown) Models 24U950,   24U951, 24U952   37   DIAL   16X599 model 24U947, 24U948,   24U949   49   50   51   52   16X610 LOCK, pawl   16X579 NEEDLE, plate   16X590 PIN   16X600 model 24U950, 24U951,   24U952   16X598 model 24U953, 24U954,   24U955   16X492 TRIGGER, guard   1 2 38   39   16X498 CLIP, ring   ‡ Included in Kit 24V466    Included in Kit 24V472    Included in Kit 24V465    Included in Kit 24V461   16X583 SPRING, inner and outer   pointer   333492B   23   Download from Www.Somanuals.com. All Manuals Search And Download.   Nozzle (101) and Extension (102) Kits   Nozzle (101) and Extension (102) Kits   Kit No.   Description   Fluid Type   Automatic, non-drip quick close nozzle with   rigid extension   255852*   Oil   Automatic, non-drip quick close nozzle with   flexible extension   24V475*   24W641*   Oil   Oil   Automatic, non-drip quick close nozzle with   short rigid extension   Non-drip, quick close nozzle with rigid   extension   255854   Gear Lube   Non-drip, quick close nozzle with rigid   extension   255855*   Antifreeze   Antifreeze   Non-drip, quick close nozzle with flexible   extension   24W306*   *Used for dispensing 5gpm (22.7 lpm) or less.   24   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Nozzle (101) Parts   Nozzle (101) Parts   Part No.   Description   Qty   Fluid Type   255459*   Automatic, non-drip, quick-close nozzle   • BODY, nozzle   Oil   1 1 1 1 1 1 • O-RING, packing   • SPRING, compression   • O-RING, packing   • STEM, nozzle, valve   • SEAT, valve   255460*   Automatic, non-drip, quick-close nozzle   • BODY, nozzle   Antifreeze   1 1 1 1 1 1 • SPRING, compression   • O-RING, packing   • STEM, nozzle, valve   • O-RING, packing   • SEAT, valve   255470   Non-drip, quick-close nozzle   • Housing   Gear Lube   1 1 1 1 1 • Body, nozzle   • O-RING, packing   • O-RING, packing   • Plug, Hollow, hex   *Used for dispensing 5gpm (22.7 lpm) or less.   333492B   25   Download from Www.Somanuals.com. All Manuals Search And Download.   Technical Data   Technical Data   Manual and Preset Meter   US   0.26 to 8 gpm   Metric   Flow rate*   1 to 30 lpm   Maximum working pressure   1500 psi   10 MPa, 103.4 bar   Weight   Manual Meter   Preset Meter   3.42 lbs   3.50 lbs   1.55 kg   1.58 kg   Length   Width   Height Manual Meter   Height Preset Meter   Maximum Totalizer Digits   Inlet   11.4 inches   3.94 inches   4.85 inches   6.33 inches   28.9 cm   10 cm   12.3 cm   16.08 cm   99,999 units**   1/2-14 NPT   1/2-14 BSPP   1/2-14 BSPT   Outlet   3/4-16 straight thread o-ring boss   Operating temperature range   Wetted parts   Fluid compatibility   -50 °F to 160°F   -45°C to 70°C   brass, aluminum, stainless steel, TPE   antifreeze, gear oil, crankcase oil   30 psi @ 4 gpm   Meter pressure loss   Accuracy - Manual Meter: Oil   Accuracy - Manual Meter: Antifreeze   Accuracy - Preset Meter: Oil or Antifreeze   +/- 1 percent   +/- 3 percent   +/- 3 percent   *Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity.   **Rolls over to 00,000 after maximum value is reached.   26   333492B   Download from Www.Somanuals.com. All Manuals Search And Download.   Graco Extended Meter Warranty   Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in   material and workmanship on the date of sale to the original purchaser for use. Graco will, for a period of five (5) years from the date of sale, repair   or replace any non-wear parts of the equipment determined by Graco to be defective. Graco will also for a period of one (1) year from the date of   sale, repair, or replace any wear parts of the equipment determined by Graco to be defective. This warranty applies only when the equipment is   installed, operated and maintained in accordance with Graco's written recommendations.   This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty   installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of   non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with   structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or   maintenance of structures, accessories, equipment or materials not supplied by Graco.   This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of   the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned   to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs   will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.   THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT   LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.   Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy   (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or   consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.   GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A   PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT   MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to   the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these   warranties.   In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or   the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the   negligence of Graco, or otherwise.   FOR GRACO CANADA CUSTOMERS   The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,   given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la   rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite   de ou en rapport, directement ou indirectement, avec les procédures concernées.   Graco Information   TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.   Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590   All written and visual data contained in this document reflects the latest product information available at the time of publication.   Graco reserves the right to make changes at any time without notice.   Original instructions. This manual contains English. MM 333492   Graco Headquarters: Minneapolis   International Offices: Belgium, China, Japan, Korea   GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA   Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.   November 2014   Download from Www.Somanuals.com. All Manuals Search And Download.   |