Graco Inc Paint Sprayer 225877 User Manual

Instructions – Parts List  
President 10:1 Ratio  
Air Spray System  
306402F  
FOR SPRAYING HEAVY FLUIDS FROM 55 GAL. (208  
liter) DRUMS  
1800 psi (126 bar) Maximum Working Pressure  
180 psi (12.6 bar) Maximum Air Input Pressure  
Model 225877  
Includes Pump, Evenflo Control, Air Supply Hose, Spray Gun, and 100  
ft (30 m) Air Atomizing and Fluid Hoses.  
Model 225886  
Has 25 ft (8 m) hoses,  
otherwise same as 225877.  
Read warnings and instructions.  
See page 2 for table of contents.  
GRACO INC.ąP.O. BOX 1441ąMINNEAPOLIS, MNą55440-1441  
Copyright 1955, Graco Inc. is registered to I.S. EN ISO 9001  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
INJECTION HAZARD  
Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely  
serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also  
cause serious injury.  
D Fluid injected into the skin is a serious injury. The injury may look like just a cut, but it is a serious  
injury. Get immediate medical attention.  
D Do not point the gun at anyone or at any part of the body.  
D Do not put your hand or fingers over the spray tip.  
D Do not stop or deflect leaks with your hand, body, glove or rag.  
D Do not “blow back” fluid; this is not an air spray system.  
D Always have the tip guard and the trigger guard on the gun when spraying.  
D Check the gun diffuser operation weekly. Refer to the gun manual.  
D Be sure the gun trigger safety operates before spraying.  
D Lock the gun trigger safety when you stop spraying.  
D Follow the Pressure Relief Procedure on page 7 if the spray tip clogs and before cleaning,  
checking or servicing the equipment.  
D Tighten all fluid connections before operating the equipment.  
D Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.  
Permanently coupled hoses cannot be repaired; replace the entire hose.  
MOVING PARTS HAZARD  
Moving parts can pinch or amputate your fingers.  
D Keep clear of all moving parts when starting or operating the pump.  
D Before checking or servicing the equipment, follow the Pressure Relief Procedure on page 7 to  
prevent the equipment from starting unexpectedly.  
306402  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
FIRE AND EXPLOSION HAZARD  
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re-  
sult in a fire or explosion and serious injury.  
D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.  
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-  
ing immediately. Do not use the equipment until you identify and correct the problem.  
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid  
being sprayed.  
D Keep the spray area free of debris, including solvent, rags, and gasoline.  
D Before operating this equipment, electrically disconnect all equipment in the spray area.  
D Before operating this equipment, extinguish all open flames or pilot lights in the spray area.  
D Do not smoke in the spray area.  
D Do not turn on or off any light switch in the spray area while spraying or while operating if fumes  
are present.  
D Do not operate a gasoline engine in the spray area.  
TOXIC FLUID HAZARD  
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,  
inhaled, or swallowed.  
D Know the specific hazards of the fluid you are using.  
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,  
state and national guidelines.  
D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and  
solvent manufacturer.  
4
306402  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
4. Spray gun or dispensing valve: ground through  
General Information  
connection to a properly grounded fluid hose and  
NOTE: Reference numbers and letters in parentheses  
in the text refer to the callouts in the figures and the  
parts drawing.  
pump.  
5. Object being sprayed: follow your local code.  
NOTE: Always use Genuine Graco Parts and Acces-  
sories, available from your Graco distributor.  
6. Solvent pails used when flushing: follow your local  
code. Use only metal pails, which are conductive,  
placed on a grounded surface. Do not place the  
pail on a nonconductive surface, such as paper or  
cardboard, which interrupts the grounding continu-  
ity.  
Grounding  
WARNING  
FIRE AND EXPLOSION HAZARD  
Before operating the pump, ground the  
system as explained below. Also read  
the section FIRE OR EXPLOSION HAZ-  
ARD on page 4.  
7. To maintain grounding continuity when flushing or  
relieving pressure, hold a metal part of the spray  
gun firmly to the side of a grounded metal pail,  
then trigger the gun.  
1. Pump: use a ground wire and clamp as shown in  
Fig. 1. Loosen the grounding lug locknut (W) and  
washer (X). Insert one end of a 12 ga (1.5 mm@)  
minimum ground wire (Y) into the slot in lug (Z)  
and tighten the locknut securely. Connect the other  
end of the wire to a true earth ground. Order part  
number 222011 Grounding Clamp and Wire.  
X
Z
Y
2. Air and fluid hoses: use only electrically conductive  
hoses.  
W
0720  
3. Air compressor: follow manufacturer’s recommen-  
Fig. 1  
dations.  
306402  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
On the main air supply line, install an air line filter (B)  
Typical Installation  
to remove harmful dirt and contaminants from your  
compressed air supply. Also install a bleed-type master  
air valve (A).  
Mount the Evenflo Control (1) to the pump, using the  
screws supplied with it to attach the mounting plate to  
the pump base. Remove the screw and lockwasher  
from the bottom of the control. Position the control  
over the small hole of the mounting plate and reinstall  
the lockwasher and screw.  
WARNING  
Remove the cover of the supply drum. Place the  
Sturdi-Clamp (3) over the edge of the drum and tighten  
the tee handle (M) screw securely. Loosen the U-  
clamp. Lower the pump through the U-clamp until the  
pump intake is about 1 in. off the bottom of the drum.  
Tighten the clamp wing nuts (N). See Detail A below.  
A bleed-type master air valve (A) is required in your  
system to reduce the risk of serious bodily injury,  
including fluid injection, splashing in the eyes, and  
injury from moving parts, if you are adjusting or  
repairing the pump. Order Part No. 107142  
This valve relieves air trapped between the valve  
and the pump after the air supply is shut off.  
Trapped air may cause the pump to cycle unex-  
pectedly. Locate the valve within easy access of  
the pump.  
NOTE: Use thread sealer on all male threads except at  
swivel connections. Swivels must remain free to move.  
Connect the air and fluid hoses to the Evenflo Control  
and the gun as shown in Fig. 2 and Fig. 4. Tape the  
hoses every 18 in. (457 mm) for easier handling.  
Connect the air hose (12*) from the 1/2 npt(f) Evenflo  
swivel air inlet to the main air supply line. Then con-  
nect the hose’s ground wire (C) to a true earth ground.  
For automatic air motor lubrication, install an air line  
lubricator between the pump air inlet and hose (E).  
Otherwise, just connect the 18 in. (457 mm) hose (E)  
from the Evenflo Control to the swivel air inlet of the  
pump. For manual air motor lubrication, see MAINTE-  
NANCE, page 9.  
Ground the pump as explained on page 5.  
Key  
B
A
C
A Bleed-type Master Air Valve  
B Air Filter  
C Air Hose Ground Wire  
E 18” Hose  
M Tee-Handle  
N Wing Nut  
1 Evenflo Control  
3 Sturdi-Clamp  
5 3/4” Union  
6 3/8” Union  
7 Swivel Union  
8 Nipple  
12  
15  
5
6
E
9 1” ID Fluid Hose  
10  
11  
12  
13  
14  
15  
3/4” ID Fluid Hose  
3/4 x 1” Union  
Air Supply Hose  
Gun Air Hose  
Pump  
14  
10  
8
7
Hand Spray Gun  
13  
11  
9
1
Detail A  
3
N
05959  
M
05958  
Fig. 2  
6
306402  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Pressure Relief Procedure  
Relax-A-Valve Automatic Position  
With the Evenflo control, its bypass valve, and the  
pump Relax-A-Valve properly set, fluid pressure is  
relieved from the pump and hose each time you re-  
lease the gun trigger. Always engage the gun trigger  
safety when you stop spraying. To relieve air pressure,  
close the Evenflo regulators and open the bleed-type  
master air valve.  
To set the pump Relax-A-Valve (G) in the automatic  
position, loosen the locknut (H), turn the T-handle (J)  
clockwise as far as possible, and then back-off the  
handle four turns and tighten the nut. See Fig. 3.  
NOTE: Every time you resume spraying, ensure that  
the Relax-A-Valve is in the automatic position.  
WARNING  
INJECTION HAZARD  
G
If you suspect that the Evenflo system is  
not properly set, or that pressure is not  
fully relieved, the system pressure must  
H
J
be manually relieved to prevent the system from  
starting or spraying accidentally. Fluid under high  
pressure can be injected through the skin and  
cause serious injury. To reduce the risk of an injury  
from injection, splashing fluid, or moving parts, fol-  
low the Pressure Relief Procedure whenever you:  
D are instructed to relieve the pressure,  
D stop spraying,  
Drain back tube  
D check or service any of the system equipment,  
D or install or clean the spray tips.  
1. Close the air regulators.  
05960  
2. Open the bleed-type master air valve.  
Fig. 3  
3. Hold a metal part of the gun firmly to the side of a  
grounded metal pail, and trigger the gun to relieve  
pressure.  
4. Lock the gun trigger safety.  
5. Carefully loosen a fluid hose fitting and relieve  
pressure gradually.  
If you suspect that the spray tip or hose is completely  
clogged, or that pressure has not been fully relieved  
after following the steps above, very slowly loosen the  
tip guard retaining nut or hose end coupling and relieve  
pressure gradually, then loosen completely. Now clear  
the tip or hose.  
306402  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
K
G
J
F
E
9
L
13  
12  
1
Fig. 4  
4. Set the Relax-A-Valve (G) to automatic.  
Mixing by Circulation (Fig. 4)  
5. Open the Evenflo ball valve (L) (handle parallel to  
body), and the bleed-type master air valve (A).  
1. Close the Evenflo bypass valve (K) by turning the  
valve handle clockwise.  
6. Set the atomizing air pressure to the gun at 40 psi  
(2.8 bar) by turning the left regulator handle clock-  
wise.  
2. Turn both air regulator handles counterclockwise  
to the free position.  
3. Disconnect the gun air atomizing hose (13*) from  
the left air regulator.  
7. Direct the gun back into the drum. Release the  
trigger safety and trigger the gun. Set the right air  
regulator to 30 psi (2.1 bar). The pump will oper-  
ate, filling the hose and gun.  
4. Open the Relax-A-Valve handle (J) fully counter-  
clockwise.  
8. Adjust the right regulator to the lowest pressure  
necessary for the desired delivery rate; this varies  
according to the fluid being pumped and other  
system characteristics.  
5. Open the bleed-type master air valve (A).  
6. Turn the left regulator handle clockwise until air  
bleeds slightly through the open union (F).  
9. Release the gun trigger, engage the trigger safety,  
and install the air cap.  
7. Turn the right regulator handle clockwise to start  
the pump. Increase the air pressure until the pump  
circulates fluid through the Relax-A-Valve return  
(drain back) tube at the desired rate.  
10. Release the trigger safety and trigger the gun.  
Adjust the left regulator until the fluid is properly  
atomized. To minimize overspray, use the lowest  
pressure necessary for good atomization.  
8. After mixing, turn both regulator handles counter-  
clockwise to the free position, connect the air  
11. Adjust the Evenflo bypass valve (K).  
atomization hose (13*) to the left regulator, and set  
the pump Relax-A-Valve in the automatic position.  
a. Be sure the Relax-A-Valve (G) is set in the  
automatic position.  
Pump Operation (Fig. 4)  
b. Be sure regulated air pressure is being sup-  
plied to the gun and pump.  
NOTE: Fluid can be mixed by circulating it before  
spraying. See Mixing by Circulation.  
c. Open the bypass valve (K) four full turns  
1. Engage the gun trigger safety. Remove the gun air  
cap; this prevents fluid from being forced back into  
the gun’s air passages.  
counterclockwise from the closed position.  
d. Trigger the gun, directing the spray into the  
drum. If the pump does not operate, release  
the trigger and close the bypass valve 1/4 turn  
clockwise.  
2. Turn the Evenflo bypass valve (K) fully in to close  
it.  
3. Set both regulators in the free position by turning  
the handles fully counterclockwise.  
e. Trigger the gun again. Repeat step d until the  
pump starts when the gun is triggered.  
8
306402  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
Flush with a fluid that is compatible with the fluid you  
WARNING  
To reduce the risk of serious injury whenever you  
are instructed to relieve pressure, always follow the  
Pressure Relief Procedure on page 7.  
are pumping and with the wetted parts in your system.  
Check with your fluid manufacturer or supplier for  
recommended flushing fluids and flushing frequency.  
Always flush the pump before fluid dries on the dis-  
placement rod.  
1. Remove and clean the strainer in the Evenflo  
body, add light oil to the screen cavity and re-  
assemble every day.  
CAUTION  
Never leave water or water-base fluid in the pump  
overnight. If you are pumping water-base fluid, flush  
with water first, then with a rust inhibitor such as  
mineral spirits. Relieve the pressure, but leave the  
rust inhibitor in the pump to protect the parts from  
corrosion.  
2. If the pump was not flushed and has not been  
operated for more than one day, disconnect the  
spray gun fluid hose, turn on the pump, and pump  
out a small quantity of fluid. This removes any fluid  
that has set-up in the hose.  
3. Whenever you are done spraying for the day,  
relieve the pressure. Cover the drum to protect it  
from contaminants and air, which may cause the  
fluid to harden.  
WARNING  
To reduce the risk of serious injury whenever you  
are instructed to relieve pressure, always follow the  
Pressure Relief Procedure on page 7.  
NOTE: Be sure you flush the system thoroughly before  
any fluid has a chance to set-up or harden.  
1. Relieve the pressure.  
2. Remove the spray gun and clean it according to  
the supplied instructions.  
Air Motor Lubrication  
If your system does not include an automatic lubrica-  
tor, remove the hose (E) to the pump air inlet. Place 15  
drops of light machine oil in the inlet. Reattach the  
hose and turn on the air to blow the oil into the motor.  
Repeat this process every day.  
3. Remove the pump from the drum. Wipe excess  
fluid off of the pump. Place the pump in a  
grounded metal flushing container, with enough  
compatible solvent for flushing the entire system.  
4. Open the bleed-type master air valve, the pump  
Relax-A-Valve, and start the pump. Circulate the  
solvent for at least 15 minutes.  
Flushing  
WARNING  
5. Close the Relax-A-Valve. DIrect the fluid hose into  
the fluid supply drum. Start the pump. When the  
solvent appears at the hose end, quickly transfer  
the hose to the flushing pail and allow the pump to  
circulate solvent through the pump and hose until  
clean.  
FIRE AND EXPLOSION HAZARD  
Before flushing, read the section FIRE  
OR EXPLOSION HAZARD on page 4.  
Be sure the entire system and flushing  
pails are properly grounded. Refer to  
Grounding on page 5.  
6. Relieve the pressure.  
306402  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Model 225877  
10:1 President Paint Sprayer  
Includes items 1, 3–15  
15  
Model 225886  
10:1 President Paint Sprayer  
Includes items 1, 3, 14–19  
5
6
13  
14  
8
12  
7
1
3
10  
11  
9
05956  
10  
306402  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Ref  
No.  
Ref  
Part No.  
Description  
Qty.  
No.  
Part No.  
Description  
Qty.  
1
3
4
5
6
7
202844  
“EVEN-FLO” CONTROL  
See manual 306479 for parts  
STURDI-CLAMP  
See manual 306305 for parts  
ACCESSORY KIT  
includes items 5–13  
. UNION, str adapter; 3/4 npt (f) x  
3/4 npt (f) swivel  
. UNION, str adapter; 3/8 npt (f) x  
3/8 npt (f) swivel  
. UNION, adapter; 1” npt (f) x  
1” npt (f) swivel  
. NIPPLE, hex pipe; 1” npt  
. HOSE, fluid; cpld 1” npt (mbe)  
1” ID 50 ft (15 m)lg  
. HOSE, fluid; cpld 3/4 not (mbe)  
3/4 ID, 50 ft (15 m) lg  
12  
214951  
. HOSE, air; cpld 3/4 x 1/2  
npt (mbe) 3/4” ID; 25 ft (8m) lg  
. HOSE, air; cpld 3/8 npt (mbe)  
1/2” ID; 100 ft (30 m) lg, static free  
10:1 PRESIDENT PUMP  
See manual 306726 for parts  
SPRAY GUN  
See manual 306494 for parts  
ACCESSORY KIT  
includes 5, 6, 12, 17–19  
. HOSE, air; cpld 3/8 npt (m). 1/2” ID;  
25 ft (8 m) lg, static free  
. HOSE, fluid; cpld 3/4 npt (m), 3/4” ID;  
25 ft (8 m) lg  
. COUPLING, 1” npt (m) x 3/4 npt (f)  
swivel  
1
1
1
1
1
1
1
1
1
203156  
203458  
156172  
156173  
158383  
13  
14  
15  
16  
17  
18  
19  
214653  
205628  
204000  
203461  
214655  
215240  
202965  
1
1
1
8
9
158585  
218986  
1
1
1
1
1
10  
11  
218689  
202966  
. UNION, adapter; 3/4 npt (f) x  
1” npt (f)  
Technical Data  
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1800 psi (126 bar)  
Pump air pressure range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40–180 psi (2.8–12 bar)  
Maximum gun air pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 psi (7 bar)  
Continuous duty delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 gpm (11 liter/min)  
Air Consumption** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.8 cfm (0.3 m#/min) at 1 gpm (3.8 liter/min)  
at 70 psi (5 bar)  
Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416 Stainless Steel, Nitralloy, Tungsten Carbide  
Steel, Aluminum, Copper, Buna-N, Nitrile Rubber  
Leather  
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Model 225877 182 lb (83 Kg)  
Model 225886 95 lb (43 Kg)  
**Additional CFM of air is required for the spray gun.  
Dimensions  
48.7”  
(1221 mm)  
20”  
(506 mm)  
Fig. 5  
306402  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Graco Standard Warranty  
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the  
date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited  
warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment  
determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accor-  
dance with Graco’s written recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by  
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-  
stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of  
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,  
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for  
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The  
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect  
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and  
transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT  
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other  
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any  
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the  
date of sale.  
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection  
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured  
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide  
purchaser with reasonable assistance in making any claim for breach of these warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment  
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,  
breach of warranty, the negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings  
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-  
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires  
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.  
Graco Information  
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers  
to identify the distributor closest to you:  
1–800–367–4023 Toll Free  
612–623–6921  
612–378–3505 Fax  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
Sales Offices: Minneapolis, Detroit  
International Offices: Belgium, Korea, Hong Kong, Japan  
PRINTED IN USA 306402 12/1955, Revised 10/2003  
12  
306402  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Outboard Motor ti18496b User Manual
Grindmaster Coffee Grinder C 2D User Manual
Hamilton Electronics Stud Sensor EPHUM011 User Manual
Harman Air Compressor 266xs User Manual
Harman Kardon Cassette Player TD212 User Manual
HP Hewlett Packard All in One Printer 4101mfp User Manual
HP Hewlett Packard Laptop 5000C CT User Manual
HTC Cell Phone HTC Touch Dual User Manual
Hunter Fan Outdoor Ceiling Fan 26106 User Manual
Husqvarna Lawn Mower Z4218 User Manual