Graco Heat Pump 332291C User Manual

Instructions  
G3 Standard Automatic  
Lubrication Pump  
332291C  
EN  
For dispensing of NLGI Grades #000 to #2 greases and oil with at least 40cSt. For  
Professional Use Only.  
Not approved for use in explosive atmospheres or hazardous locations.  
Part Nos., page 3  
5100 psi (35.1 MPa, 351.6 bar) Maximum Working Pressure  
Important Safety Instructions  
Read all warnings and instructions in this  
manual. Save these instructions.  
TI14705  
Conforms to ANSI/UL 73  
Certified to CAN/CSA  
Std. 22.2 No 68-09  
3132066  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Part / Model Numbers  
Part / Model Numbers  
The Part Number is a six-digit unique number that is only used to order the G3 Pump. Directly related to this six digit  
Part Number is the configured Graco Model Number. This configured number identifies the distinct features of a spe-  
cific G3 Pump. To help you understand each component that makes up the Model Number see Understanding Your  
Model Number, page 4. The tables below shows the relationship between each Part Number and its related Model  
Number.  
2 Liter Models  
8 Liter Models  
Part  
Numbers  
Part  
Model Number  
Model Number  
Numbers  
96G039  
96G041  
96G000 G3-G-12NC-2L0000-00C00000  
96G001 G3-G-24NC-2L0000-00C00000  
96G002 G3-G-ACNC-2L0000-0D000000  
96G003 G3-G-12NC-2L0A00-L0C00000  
96G005 G3-G-24NC-2L0A00-L0C00000  
96G006 G3-G-24NC-2FA00-L0C00000  
96G007 G3-G-ACNC-2L0A00-LD000000  
96G008 G3-G-ACNC-2LFA00-LD00000  
96G050 G3-A-24NC-2L0A00-L0C00000  
96G059 G3-A-ACNC-2L0A00-LD000000  
96G182 G3-G-24NC-2L0A00-0D00L000  
G3-G-12NC-8L0000-00C00000  
G3-G-24NC-8L0000-00C00000  
G3-G-ACNC-8L0000-0D000000  
G3-G-12NC-8L0A00-L0C00000  
G3-G-24NC-8L0A00-L0C00000  
G3-A-24NC-8L0A00-L0C00000  
G3-G-ACNC-8L0A00-LD000000  
G3-A-ACNC-8L0A00-LD000000  
G3-G-ACNC-8LFA00-0D00L000  
96G043  
96G045  
96G049  
96G052  
96G056  
96G061  
96G187  
12 Liter Models  
4 Liter Models  
Part  
Model Number  
Numbers  
Part  
Model Number  
Numbers  
96G057  
96G171  
G3-G-ACNC-120A00-LD000000  
G3-G-24NC-120000-00C00000  
96G038 G3-G-12NC-4L0L00-00C00000  
96G040 G3-G-24NC-4L0000-00C00000  
96G042 G3-G-ACNC-4L0000-0D000000  
96G044 G3-G-12NC-4L0A00-L0C00000  
96G048 G3-G-24NC-4L0A00-L0C00000  
96G051 G3-A-24NC-4L0A00-L0C00000  
96G053 G3-G-24NC-4LFA00-L0C00000  
96G055 G3-G-ACNC-4L0A00-LD000000  
96G060 G3-A-ACNC-4L0A00-LD000000  
96G062 G3-G-ACNC-4LFA00-LD000000  
96G179 G3-G-ACNC-4LFA00-0D00L000  
96G184 G3-G-24NC-4L0A00-0D00L000  
16 Liter Models  
Part  
Model Number  
Numbers  
96G058  
96G172  
G3-G-ACNC-160A00-LD000000  
G3-G-24NC-160000-00C00000  
332291C  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Part / Model Numbers  
Understanding the Model Number  
Use the Code Sample provided below to identify each component’s location in the Model Number. The options for  
each component that make up the code are provided on the lists below.  
NOTE: Other pump configurations are available that are not documented in this manual. Contact Graco Customer  
Service or your local Graco distributor for assistance.  
G
3
-
G
-
N
b
C
b
0
f
0
f
0
j
0
0
0
p
Code Sample:  
a
a
-
c
c
d
e
-
g
h
i
k
m n  
G3 - G = Identifies pump as being a G3; G = Grease  
G3 - A = Identifies pump as being a G3; A = Oil  
0 = No Follower Plate  
Code e: Low Level Option  
Code aa: Power Source  
A = External Low Level  
0 = No Low Level monitoring  
12 = 12 Volts DC  
24 = 24 Volts DC  
AC = 100 - 240 Volts AC  
Code ff: Options  
00 = No Options  
Code bb: Operation Control  
NC = No Controller  
Code cc: Reservoir Capacity (Liters)  
Code g, h, i, j, k, m, n, p  
NOTE: Codes g - p relate to a specific location on the  
G3 pump. See FIG. 1 for these locations.  
2L = 2 Liters  
4L = 4 Liters  
8L = 8 Liters  
12 = 12 Liters  
16 = 16 Liters  
C = CPC  
D = DIN  
L = Low Level  
0 = Not populated  
Code d: Follower Plate Installed  
F = Follower Plate Installed  
k
m
h
g
i
p
j
n
FIG. 1  
4
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Warnings  
Warnings  
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-  
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When  
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific  
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where  
applicable.  
WARNING  
ELECTRIC SHOCK HAZARD  
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause  
electric shock.  
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing  
or installing equipment.  
• Connect only to grounded power source.  
• All electrical wiring must be done by a qualified electrician and comply with all local codes and  
regulations.  
EQUIPMENT MISUSE HAZARD  
Misuse can cause death or serious injury.  
Do not operate the unit when fatigued or under the influence of drugs or alcohol.  
Do not exceed the maximum working pressure or temperature rating of the lowest rated system  
component. See Technical Data in all equipment manuals.  
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all  
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information  
about your material, request MSDS from distributor or retailer.  
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.  
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-  
facturer’s replacement parts only.  
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create  
safety hazards.  
Make sure all equipment is rated and approved for the environment in which you are using it.  
Use equipment only for its intended purpose. Call your distributor for information.  
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.  
Do not kink or over bend hoses or use hoses to pull equipment.  
Keep children and animals away from work area.  
Comply with all applicable safety regulations.  
332291C  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Warnings  
WARNING  
SKIN INJECTION HAZARD  
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This  
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical  
treatment.  
Do not point dispensing device at anyone or at any part of the body.  
Do not put your hand over the fluid outlet.  
Do not stop or deflect leaks with your hand, body, glove, or rag.  
Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or  
servicing equipment.  
+
Tighten all fluid connections before operating the equipment.  
Check hoses and couplings daily. Replace worn or damaged parts immediately.  
PRESSURIZED EQUIPMENT HAZARD  
Over-pressurization can result in equipment rupture and serious injury.  
• A pressure relief valve is required at each pump outlet.  
• Follow Pressure Relief Procedure in this manual before servicing.  
PLASTIC PARTS CLEANING SOLVENT HAZARD  
Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or  
property damage.  
Use only compatible water-based solvents to clean plastic structural or pressure-containing parts.  
See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent  
manufacturer’s MSDSs and recommendations.  
MOVING PARTS HAZARD  
Moving parts can pinch, cut or amputate fingers and other body parts.  
Keep clear of moving parts.  
Do not operate equipment with protective guards or covers removed.  
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,  
follow the Pressure Relief Procedure and disconnect all power sources.  
PERSONAL PROTECTIVE EQUIPMENT  
Wear appropriate protective equipment when in the work area to help prevent serious injury, including  
eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is  
not limited to:  
Protective eyewear, and hearing protection.  
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer  
6
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Installation  
Grounding  
The equipment must be grounded. Grounding reduces the risk of electric shock by providing an escape wire  
for the electrical current in the event of malfunction or breakdown. This product is equipped with a cord having  
an equipment grounding conductor. The wire with insulation having an outer surface that is green with or  
without yellow stripes is the grounding wire.  
Component Identification  
M
K
A
L
Oil Models  
Grease Models  
C
Grease Models with Follower  
Plate  
E
D
H
F
J
I
96GXXX  
B
G3-G-24NC-2L0A00-L0C00000  
FIG. 2:  
Key:  
A
B
Reservoir  
H
I
Power / Sensor Panel (both sides; only one side shown)  
Part Number / Model Number example only shown, (see  
page 4, Understanding the Model Number, for details)  
Power Cord (DIN shown)  
Follower Plate (grease models only / not available on all  
grease models)  
Vent Hole for Follower Plate (grease models only / not  
available on all grease models)  
Fill cap (oil models only)  
Adjustable Pump Element (1 included. Can accommodate 3  
total)  
C
Pressure Relief Valve (Not included / required for each outlet  
- Available from Graco. See Parts, page 30.)  
Zerk Inlet Fill Fitting (1 included / grease models only)  
Pump Outlet Plug (2 included)  
Volume Control Spacers (2 included. More spacers = less  
output volume per stroke) (also see FIG. 13, page 19)  
Fuse (DC models only - Not included, not shown. Available  
from Graco. See Parts, page 30.)  
J
K
D
E
F
L
M
G
332291C  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Typical Installation  
Divider Installations  
B
D
E
A
F
Injector Installations  
E
B
H
D
F
A
G
A Connected to fuse / power  
B Pressure relief valve (Not included/ required for each outlet -  
user supplied. See Parts, page 30)  
F - Proximity Switch (Divider Installations)  
- Pressure switch (Injector Installations)  
G Vent valve (Not included / available from Graco. See Parts,  
D Series progressive divider valves (Divider Installations)  
- Injectors (Injector Installations)  
page 31.)  
H Return to reservoir  
E To lube points  
8
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Choosing an Installation Location  
AUTOMATIC SYSTEM ACTIVATION HAZARD  
If the system is equipped with has an automatic timer (user supplied) that activates the pump lubrication system  
when power is connected or when exiting the programming function, unexpected activation of the system could result  
in serious injury, including skin injection and amputation.  
Before you install or remove the lubrication pump from the system, disconnect and isolate all power supplies and  
relieve all pressure.  
Select a location that will adequately support  
the weight of the G3 Pump and lubricant, as  
well as all plumbing and electrical connections.  
Always mount the G3 oil models upright.  
If the G3 grease model is going to be operated  
in a tilted or inverted position for any period of  
time, you must use a model that includes a fol-  
lower plate, otherwise the G3 must be mounted  
upright. Refer to your model number to confirm  
if a follower plate was installed on your pump.  
See page 4, Understanding the Model Number  
to identify this character in your model number.  
Refer to the two mounting hole layouts provided  
in the Mounting Pattern section of this manual,  
page 33.  
NOTE: The two mounting hole layouts provided  
in the Technical Data section show the only cor-  
rect installation patterns to use for mounting the  
G3. No other installation configurations should  
be used.  
Use the three fasteners (included) to secure the  
G3 to the mounting surface.  
Some installations may require an additional  
reservoir support bracket. Consult your Graco  
distributor for assistance with this installation.  
Use designated mounting holes and provided  
configurations only.  
332291C  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
System Configuration and Wiring  
Fuses  
NOTICE  
Improper installation of the grounding conductor may  
Fuses (user supplied) are required on all DC mod-  
els. To avoid equipment damage:  
result in a risk of electric shock. This product must be  
installed by a qualified electrician in compliance with  
all state and local codes and regulations.  
Never operate G3 Pump DC models without a  
fuse installed.  
If the product is permanently connected:  
A fuse of the correct voltage must be installed in  
line with the power entry to the system.  
it must be installed by a qualified electrician or ser-  
viceman.  
Fuse Kits are available from Graco. The following Table  
identifies the correct fuse to use for your input voltage  
and the corresponding Graco Kit number.  
it must be connected to a grounded, permanent wir-  
ing system.  
If an attachment plug is required in the end use  
application:  
Input Voltage  
12 VDC  
Graco Kit No.  
571039  
Fuse Value  
7.5 A  
it must be rated for the product electrical specifica-  
tions.  
24 VDC  
571040  
4 A  
it must be an approved, 3-wire grounding type  
attachment plug.  
Recommendations for Using Pump in  
Harsh Environments  
it must be plugged into an outlet that is properly  
installed and grounded in accordance with all local  
codes and ordinances.  
Use pump with CPC style power cable.  
If using a DIN style power or alarm harness with a  
right angle mating connector, make sure the con-  
nector does not exit the unit in the UP direction.  
when repair or replacement of the power cord or  
plug is required, do not connect the grounding wire  
to either flat blade terminal.  
Use a corrosion preventative electrical grease on all  
contacts.  
10  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Wiring and Installation Diagrams  
The following Table identifies the wiring and installation diagrams for the cable included with the pump provided in  
this manual.  
Diagram  
Page #  
12  
Symbol  
Power DIN AC  
Power DIN DC  
Power CPC DC  
13  
14  
Low Level Outputs  
15  
332291C  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Power DIN AC - 15 foot: Part No. 16U790  
Pin and Related Wire Color (FIG. 3)  
Pin Pin Name  
Color  
1
2
3
4
Line  
NEUTRAL  
Not Used Not Used  
GROUND Green  
Black  
White  
Connector on Housing  
Connector on Cable  
(4)  
(4)  
(2)  
(1)  
(1)  
(2)  
(3)  
Example Wiring Diagram  
1
2
3
4
FIG. 3  
12  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Power DIN DC - 15 foot: Part No. 16U790  
NOTICE  
Be sure when power is applied that stirring paddle  
rotates clockwise (when viewed from the top). If it is  
wired incorrectly paddle could rotate counter-clockwise  
which will damage the pump’s internal components. If  
this happens, stop the pump immediately and wire unit  
correctly.  
Pin and Related Wire Color (FIG. 5)  
Pin  
Pin Name  
Color  
1
2
3
4
-VDC  
+VDC  
Not Used  
Not Used  
Black  
White  
Not Used  
Green  
FIG. 4  
Connector on Housing  
Connector on Cable  
(4)  
(4)  
(2)  
(1)  
(1)  
(2)  
(3)  
Example Wiring Diagram  
Ignition Switch  
1
2
3
4
Fuse  
12V-pump - 7.5A - Graco kit #571039  
24V pump - 4A - Graco kit #571040  
FIG. 5  
332291C  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Power CPC DC - 15 foot: Part No. 126217  
Pin and Related Wire Color (FIG. 6)  
Pin Pin Name  
Color  
1
2
3
4
5
6
7
Not Used  
-VDC  
+VDC  
Not Used  
Not Used  
Not Used  
Not Used  
Not Used  
Black  
White  
Not Used  
Not Used  
Not Used  
Green  
Connector on Housing  
Connector on Cable  
(2)  
(2)  
(3)  
(1)  
(3)  
(1)  
(7)  
(4)  
(6)  
(7)  
(4)  
(5)  
(5)  
(6)  
Example Wiring Diagram  
1
2
3
4
5
6
7
Ignition Switch  
Fuse  
12V-pump - 7.5A - Graco kit #571039  
24V pump - 4A - Graco kit #571040  
FIG. 6  
14  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Low Level Outputs  
See Low Level Output Option, page 22 for functional description. See Technical Data, page 32 for ratings.  
Pin Pin Name  
1
2
3
4
Not Used  
Not Used  
LL N.O.  
LL COM  
Connector on Housing  
Connector on Housing  
(4)  
(4)  
(3)  
(1)  
(1)  
(2)  
(3)  
(2)  
Example Wiring Diagram  
G3  
1
2
3
4
FIG. 7  
332291C  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Part No. 124333: Cable Pin Out (M12)  
Part No. 124300: Field Wireable Pin Out  
(M12)  
Wire Colors  
Item No. Color  
Wire Colors  
Item No. Color  
1
2
3
4
Brown  
White  
Blue  
Brown  
White  
Blue  
1
2
3
4
Black  
Black  
ꢓꢉꢔꢊꢇꢋꢕꢐꢍꢋꢖꢗꢘ  
ꢆꢇꢈꢉꢊꢇꢋꢌꢍꢎꢋꢏꢐꢇꢑ  
ꢆꢐꢇꢊꢎꢋꢙꢐꢚꢇꢉꢔꢊꢇꢋꢕꢐꢍꢋꢖꢗꢘ  
ꢀꢄꢂ  
ꢆꢇꢈꢉꢊꢇꢋꢌꢍꢎꢋꢏꢐꢇꢑ  
ꢀꢅꢂ  
ꢀꢄꢂ  
ꢀꢅꢂ  
ꢀꢃꢂ  
ꢀꢃꢂ  
ꢀꢁꢂ  
ꢒꢉꢊꢇꢋꢌꢍꢎꢋꢏꢐꢇꢑ  
ꢀꢁꢂ  
FIG. 9  
ꢀꢄꢂ  
ꢀꢃꢂ  
ꢀꢅꢂ  
ꢀꢁꢂ  
FIG. 8  
16  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Part No. 124594: 4 Pin Eurofast Field  
Wireable Connector  
Part No. 124595: 5 Pin Eurofast Field  
Wireable Connector  
ꢀꢅꢂ  
ꢀꢄꢂ  
ꢀꢄꢂ  
ꢀꢃꢂ  
ꢀꢁꢂ  
ꢀꢅꢂ  
ꢀꢛꢂ  
ꢀꢁꢂ  
ꢀꢃꢂ  
FIG. 11  
FIG. 10  
332291C  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup  
Connecting to Auxiliary Fittings  
Setup  
Pressure Relief  
Follow the Pressure Relief Procedure whenever  
you see this symbol.  
NOTICE  
Do not attach unsupported equipment to auxiliary fit-  
tings such as fill ports and pump element. Attaching  
unsupported equipment to these fitting can result in  
irreparable housing damage.  
This equipment stays pressurized until pressure is  
manually relieved. To help prevent serious injury  
from pressurized fluid, such as skin injection,  
splashing fluid and moving parts, follow the Pressure  
Relief Procedure when you stop spraying and before  
cleaning, checking, or servicing the equipment.  
Always use two wrenches working in opposite  
directions when connecting anything to pump  
element or auxiliary fittings. See FIG. 12 for an  
example.  
Torque pump element fittings to 50 in. lbs (5.6  
N•m).  
Relieve pressure in system using two wrenches work-  
ing in opposite directions on pump element and pump  
element fitting to slowly loosen fitting only until fitting  
is loose and no more lubricant or air is leaking from fit-  
ting.  
When connecting pump element into housing  
torque to 50 in. lbs (5.6 N•m).  
Pressure Relief Valves  
NOTE: When loosening pump element fitting, do NOT  
loosen pump element. Loosening pump element will  
change the output volume.  
To prevent over-pressurization, which can result in  
equipment rupture and serious injury, a pressure relief  
valve appropriate for the lubrication system must be  
installed close to every pump outlet to alleviate unin-  
tended pressure rises in the system and protect the G3  
pump from damage.  
Only use a pressure relief valve that is rated for no  
more than the working pressure of the G3 pump it  
is installed on. See Technical Data, page 27.  
Install a pressure relief valve close to every pump  
outlet; before any auxiliary fitting.  
NOTE: A pressure relief valve can be purchased from  
Graco. See Parts, page 30.  
FIG. 12  
18  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Setup  
3. Tighten pump element fitting. Torque fitting to 50 in.  
lbs (5.6 N•m).  
Setting Pump Outlet Volume  
NOTE:  
Before making any adjustments to pump volume,  
Relieve Pressure following procedure on page 18.  
Only use Graco supplied spacers to control output  
volume.  
It may be necessary to repeat this outlet volume  
setup procedure after the pump is operating to  
re-adjust the volume of dispensed fluids.  
FIG. 13  
1. Use a wrench to turn pump element counter-clock-  
wise to loosen. Do not remove entire pump element.  
Only back pump element out enough to allow  
spacer to be slid on or off.  
Loading Grease  
To ensure optimal performance from the G3:  
Only use NLGI #000 - #2 greases appropriate for  
your application, automatic dispensing, and the  
equipment’s operating temperature. Consult with  
machine and lube manufacturer for details.  
2. If needed, remove or insert spacers to achieve  
required pump output volume. A tool may be  
needed to facilitate removal.  
The reservoir can be filled using a hand operated  
pump, pneumatic pump or electric transfer pump.  
Pump volume control is set using either no (0) spac-  
ers, 1 or 2 spacers (FIG. 13).  
Do not overfill (FIG. 15).  
Do not use more than 2 spacers to adjust output vol-  
ume.  
Do not operate G3 without reservoir attached.  
NOTICE  
Output Volume / Minute  
Always clean fitting (D) with a clean dry cloth  
prior to filling reservoir. Dirt and/or debris can  
damage pump and/or lubrication system.  
No. Spacers cubic inches  
cubic cm  
2
1
0
0.12  
0.18  
0.25  
2
3
4
• Care must be used when filling the reservoir  
using a pneumatic or electric transfer pump to  
not pressurize and break the reservoir.  
NOTE:  
The amount of dispensed volume can vary depend-  
ing on external conditions such as lubricant tem-  
perature and back pressure from downstream  
connections.  
Use of these volume adjustment in conjunction with  
setting the ON time of the pump will allow for control  
of the output volume.  
Use these volume adjustments as a starting point  
and adjust as necessary to ensure desired lubrica-  
tion dispense.  
332291C  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Setup  
For models using an external controller, start pump  
operation per your controller specifications.  
Models without a follower plate:  
1. Connect fill hose to inlet fitting (FIG. 14).  
3. Fill reservoir with grease until seal of follower plate  
breaches the vent hole (FIG. 16) and the majority of  
air is expelled from the reservoir.  
E
D
vent hole  
FIG. 14  
2. For higher viscosity fluids, start pump to rotate stir-  
ring paddle during fill to prevent air pockets from  
forming in grease.  
FIG. 16  
For models using an external controller, start pump  
operation per your controller specifications.  
NOTE: Vent port, located in rear of reservoir, should not  
be used as an overfill port/indicator.  
4. Remove fill hose.  
3. Fill reservoir with NLGI grease to max fill line.  
NOTE: Vent port, located in rear of reservoir, should not  
be used as an overfill port/indicator.  
Changing Greases  
When changing greases, always use compatible fluids  
or greases.  
max fill line  
FIG. 15  
4. Remove fill hose.  
Models with a follower plate:  
1. Connect fill hose to inlet fitting (FIG. 14).  
2. For higher viscosity fluids, start pump to rotate stir-  
ring paddle during fill to prevent air pockets from  
forming in grease.  
20  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Setup  
Filling Oil Unit  
Only use oil appropriate for your application, auto-  
matic dispensing, and the equipment’s operating  
temperature. Consult with machine and lube manu-  
facturer for details.  
The reservoir can be filled using a hand operated  
pump, pneumatic pump or electric transfer pump.  
Do not overfill (FIG. 17).  
Do not operate G3 without reservoir attached.  
Only use oils with viscosity at least 40 cSt.  
FIG. 18  
2. Only run pump until air is no longer dispensed with  
the lubricant coming out of element fitting (FIG. 19).  
a
b
FIG. 17  
1. Remove fill cap (a).  
2. Pour oil into reservoir to fill line (b).  
3. Replace fill cap. Hand tighten cap, securely.  
FIG. 19  
3. Tighten pump element fitting using two wrenches  
working in opposite directions (FIG. 18).  
Priming  
NOTE: It is not necessary to prime pump every time  
pump is filled with lubricant.  
Pump only requires priming the first time it is used or if it  
is allowed to run dry.  
1. Loosen pump element fitting (FIG. 18).  
NOTE: When loosening pump element fitting, do NOT  
loosen pump element. Loosening pump element will  
change the output volume  
332291C  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
No Controller Operation  
No Controller Operation  
The G3 Pump can be controlled using an external, user  
supplied, power source and controller.  
Low Level Output Option  
Some G3 pumps without controllers include a Low Level  
Output Option. It can be configured with an M12 con-  
nector in code location “G” or with a DIN connector in  
code location “K”. (See Understanding the Model Num-  
ber, page 4.)The low level signal is monitored across  
PINS 3 and 4. For PIN 3 and 4 locations and wiring  
information the Low Level Outputs diagram, page 15.  
Refer to the Typical Installation diagrams provided on  
page 8 for correct location of the required pump ground  
wire and fuses.  
NOTE:  
When using an external power source and control-  
ler, Pump ON (Run) Time should be set for no lon-  
ger than 30 minutes.  
NOTE: A low level warning is triggered when the con-  
troller detects PINS 3 and 4 have momentarily closed.  
In most cases, Pump OFF (Rest) Time should be  
twice as long as Pump ON (Run) time. If alternative  
ON / OFF times are required, contact Graco Cus-  
tomer Service for assistance.  
Grease Pumps  
When the grease level has reached a low warning level,  
PINS 3 and 4 momentarily close (1 time per paddle rev-  
olution) sending the signal that the fluid has reached a  
low level to the controller.  
To ensure that a low level condition has been met, 3 or  
more low level triggers must be detected within 1 minute  
or less.  
See FIG. 20 for an illustration of a typical Low Level Out-  
put response to low grease level.  
Typical Low Level Output Response with Low Level Fluid in Grease Models  
200 ms  
Closed  
Contact  
Position  
Open  
3 s  
FIG. 20  
22  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No Controller Operation  
Oil Pumps  
To ensure that a low level condition has been met, the  
low level trigger must be detected for 10 continuous sec-  
onds.  
When the oil level has reached a low warning level,  
PINS 3 and 4 close, sending the signal to the controller  
that the fluid has reached a low level.  
See FIG. 21 for an illustration of a typical Low Level Out-  
put response to low oil level.  
Typical Low Level Output Response with Low Level Fluid in Oil Models  
Closed  
Contact  
Position  
Open  
FIG. 21  
332291C  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Troubleshooting  
Problem  
Cause  
Solution  
Incorrect/loose wiring  
Refer to Installation instructions,  
page 7.  
Unit does not power on  
Tripped external fuse due to internal  
component failure  
Contact Graco Customer Service.  
Unit does not power on (DC models Tripped external fuse due to pump-  
Replace lubricant with pumpable  
lubricant, rated for environmental  
conditions and application.  
only)  
ing non-cold weather lubricant in  
cold weather -13°F (-25°C)  
Replace fuse.  
Unit does not power on (AC models Tripped internal power supply fuse  
Contact Graco Customer Service.  
Replace reservoir.  
only)  
due to power supply failure  
Reservoir retaining tabs are  
cracked or broken  
Lubricant leaks past seal located on Reservoir is being pressurized  
Ensure vent hole is not plugged.  
the bottom of the reservoir  
during filling  
If problem persists, contact Graco  
Customer Service or your local  
Graco distributor for assistance.  
Unit not pumping during ON cycle,  
but external controller functions  
Failed motor  
Replace unit.  
Air is trapped in the reservoir  
Add grease following Loading  
Follower plate is not going down  
between the follower plate and lubri- Grease instructions, page 19.  
cant Ensure air is purged.  
Pump takes several minutes before Pumping non-cold weather lubricant Add 1 stroke adjust spacer and  
it begins pumping at the highest  
pump volume setting (no stroke  
adjust spacers installed)  
in cold weather -13°F (-25°C)  
adjust lube cycle time to accommo-  
date the difference in pump volume  
per stroke.  
In an Injector System without sen-  
sor feedback, unit does not vent  
properly  
Vent valve time needs to be config- Adjust external vent valve control  
ured time.  
24  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Maintenance  
Maintenance  
Frequency  
Component  
Zerk Fittings  
Required Maintenance  
Keep all fittings clean using a clean  
dry cloth. Dirt and/or debris can dam-  
age pump and/or lubrication system.  
Daily and at refill  
Daily  
G3 Pump Unit and Reservoir  
External Wiring Harness  
Keep pump unit and reservoir clean  
using a clean dry cloth.  
Monthly  
Verify external harnesses are  
secure.  
332291C  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts - 2 Liter Models  
Parts - 2 Liter Models  
40b  
Follower Plate  
Models Only  
Low Level Grease Models Only  
45  
40a  
43  
44  
42  
35  
57  
27  
1
41  
16  
36  
60  
23  
13  
15  
Low Level Oil Models Only  
67  
12  
14  
18  
37  
3
21  
66  
1
33  
17  
3
1
2
3
Torque to 4 in. lbs (0.45 N.m)  
Torque to 30 in. lbs (3.4 N.m)  
Torque to 50 in. lbs (5.6 N.m)  
3
2
4
26  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts - 4 Liter and Larger Models  
Parts - 4 Liter and Larger Models  
Follower Plate  
Models Only  
40a  
40b  
43  
44  
Low Level Grease Models Only  
45  
41  
36  
42  
35  
57  
27  
1
61  
16  
62  
13  
60  
23  
15  
12  
14  
18  
Low Level Oil Models Only  
67  
3
37  
1
21  
17  
33  
66  
3
1
2
3
Torque to 4 in. lbs (0.45 N.m)  
Torque to 30 in. lbs (3.4 N.m)  
Torque to 50 in. lbs (5.6 N.m)  
3
4
2
332291C  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
Parts  
Ref  
Part  
Description  
Qty  
Ref  
1
Part  
Description  
BASE, three pump housing  
Qty  
1
PADDLE, low level, models  
96G003-96G008, 96G038,  
96G044, 96G045, 96G048,  
3
278142 COVER, bottom, with seal  
1
23  
278136 96G049, 96G053,  
96G055-96G058, 96G062,  
1
4
115477 SCREW, mach, torx pan hd  
RECT-RING, included in kit  
9
96G179, 96G182, 96G184,  
96G187  
SCREW, M6, models  
96G003-96G008, 96G038,  
96G044, 96G045, 96G048,  
12 127079  
1
2
571042, 571069, 571179  
O-RING, 258, included in Kit  
13 124396 571042, 571044, 571045, 571069,  
571179  
27 123025 96G049, 96G053,  
96G055-96G058, 96G062,  
1
1
14  
15  
PLATE, ricer  
1
1
96G179, 96G182, 96G184,  
96G187  
BEARING, ball  
33  
PADDLE, stirring, 2 Liter models  
without follower plate - models  
96G000, 96G001, 96G002,  
96G003, 96G005, 96G007,  
96G182, included in Kit 571044,  
PADDLE, stirring, 4 Liter models  
without follower plate - models  
96G038, 96G040, 96G042,  
96G044, 96G048, 96G055,  
96G184  
16A579 LABEL, safety  
1
WIPER, stirring, models without  
follower plate - models 96G000,  
96G001, 96G002, 96G003,  
96G005, 96G007,  
96G038-96G045, 96G048,  
96G049, 96G055-96G058,  
96G171, 96G172, 96G182,  
96G184, included in Kit 571044  
WIPER, stirring, models with fol-  
lower plate - models 96G006,  
96G008, 96G053, 96G062,  
96G179, 96G187, included in Kit  
571045  
35  
1
1
1
PADDLE, stirring, 8 Liter models  
without follower plate - models  
96G039, 96G041, 96G043,  
96G045, 96G049, 96G056  
1
16  
PADDLE, stirring, 12 Liter models  
without follower plate - model  
96G057, 96G171  
PADDLE, stirring, 16 Liter models  
without follower plate - model  
96G058, 96G172  
1
1
36  
LABEL, brand  
1
1
FITTING, zerk, grease, not  
37 123741 included on models  
96G050-96G052, 96G059-96G061  
RESERVOIR, 2 liter, grease,  
40a 24E984 96G000-96G008, 96G182,  
included in Kit 571042, 571069  
PADDLE, stirring, 2 Liter models  
with follower plate - models  
96G006, 96G008, included in Kit  
571045  
PADDLE, stirring, 4 liter models  
with follower plate - models  
96G053, 96G062, 96G179  
1
1
1
RESERVOIR, 2 liter, oil, 96G050,  
96G059, included in Kit 571179  
40b 16G021  
RESERVOIR, 4 liter, grease,  
96G038, 96G040, 96G042,  
1
1
40a 24B702 96G044, 96G048, 96G053,  
96G055, 96G062, 96G179,  
1
1
PUMP, element, included in Kit  
571041  
17  
96G184, included in Kit 571183  
RESERVOIR, 4 liter, oil, 96G051,  
SPACER, stroke adjust, included  
in Kit 571041  
18 16F368  
2
2
40b 16G020  
96G060  
21 278145 PLUG, pump, 3/4-16  
28  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
Ref  
Part  
Description  
Qty  
Ref  
Part  
Description  
Qty  
RESERVOIR, 8 liter, grease,  
96G039, 96G041, 96G043,  
96G045, 96G049, 96G056,  
96G187  
LABEL, models 96G002, 96G007,  
96G008, 96G042, 96G043,  
96G055-96G062, 96G179,  
96G187  
58  
40a  
1
196548  
1
RESERVOIR, 8 liter, oil, 96G052,  
96G061, included in Kit 571182  
WASHER, low level, models  
96G003-96G008,  
96G033-96G038,  
96G044-96G045, 96G048,  
96G049, 96G053,  
96G055-96G058, 96G062,  
96G179, 96G182, 96G184,  
96G187  
40b  
40a  
40a  
1
1
1
1
2
1
1
1
RESERVOIR, 12 liter, 96G057,  
96G077, 96G171  
RESERVOIR, 16 liter, 96G058,  
96G172  
SEAL, follower plate, 2 liter models  
96G006, 96G008  
60 16D984  
2
278139  
16F472  
41  
42  
43  
44  
RESERVOIR, mid-section, 8 liter  
models 96G039, 96G041,  
96G043, 96G045, 96G049,  
96G052, 96G056, 96G061,  
96G187  
RESERVOIR, mid-section, 12 liter  
models 96G057, 96G171  
RESERVOIR, mid-section, 16 liter  
models 96G058, 96G172  
SEAL, follower plate, 4 liter models  
96G053, 96G062, 96G179  
PLATE, follower, 2 liter models  
96G006, 96G008  
PLATE, follower, 4 liter models  
96G053, 96G062, 96G179  
1
61  
62  
2
3
ROD, follower plate, 2 liter models  
96G006, 96G008  
ROD, follower, 4 liter models  
96G053, 96G062, 96G179  
SPRING, compression, 2 liter  
models 96G006, 96G008  
ADAPTER, reservoir, models  
96G038-96G045, 96G048,  
96G049, 96G051-96G053,  
96G055, 96G057, 96G058,  
96G060-96G062, 96G171,  
96G172, 96G179, 96G184,  
96G187  
1
1
1
SPRING, compression, 4 liter  
models 96G053, 96G062, 96G179  
BAFFLE, low level, 2 liter models  
45† 24D838 96G003, 96G005, 96G007,  
96G182  
1
1
1
NUT, oil, models 96G050,  
66 126417 96G051, 96G052, 96G059,  
96G060, 96G061  
BAFFLE, low level, 4 liter models  
24E246 96G044, 96G048, 96G055,  
96G184  
BAFFLE, low level, 8 liter models  
24F836 96G045, 96G049, 96G052,  
96G056, 96G061  
FLOAT, oil, models 96G050,  
67 24N806 96G051, 96G052, 96G059,  
96G060, 96G061  
CABLE,15 ft (4.5 m), SOOW  
126217 w/7pos, 3 pin, 90 deg (See Wiring  
1
1
Diagram, page 14)  
CABLE, DIN, bare, (See Wiring  
Diagram, page 12)  
200  
BAFFLE, low level, 12 liter models  
96G057  
24F923  
1
1
16U790  
BAFFLE, low level, 16 liter models  
96G058  
24F924  
BEARING, sleeve, models  
96G003-96G008, 96G038,  
96G044-96G045, 96G048,  
57 117156 96G049, 96G053,  
96G055-96G058, 96G062,  
1
96G179, 96G182, 96G184,  
96G187  
332291C  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
NOTE: Turning adjustment screw (a) clockwise  
increases pressure.  
Ref  
Part  
Description  
Qty  
CABLE, M12, 15 ft., 4 wire, straight  
124300 male to flying leads (See Wiring  
Diagram, page 16)  
1
Part  
Description  
Qty  
201  
VALVE, pressure relief, 500-3500 psi  
(3.44 MPa, 34.4 bar - 24.1 MPa, 241  
bar), Set pressure 3000 psi + 10%  
(20.68 MPa, 206.8 bar + 10%)  
Included in Kit 571028  
CABLE, M12, 15 ft., 4 wire, straight  
124333 male to female (See Wiring Dia-  
gram, page 16)  
1
16C807  
1
CONNECTOR, Eurofast, fem,  
straight, 4 Pin  
1
1
1
124301  
VALVE, pressure relief, 750 psi (5.17  
MPa, 51.71 bar)  
VALVE, pressure relief, 1000 psi  
(6.89 MPa, 68.95 bar)  
VALVE, pressure relief, 1500 psi  
(10.34 MPa, 103.42 bar)  
563156  
563157  
563158  
563159  
563160  
563161  
1
1
1
1
1
1
CONNECTOR, Eurofast, 4 Pin  
(see wiring diagram, page 17)  
CONNECTOR, Eurofast, 5 Pin  
(see wiring diagram, page 17)  
202 124594  
124595  
Replacement Danger and Warning labels, tags and  
cards are available at no cost.  
VALVE, pressure relief, 2000 psi  
(13.78 MPa, 137.89 bar)  
VALVE, pressure relief, 2500 psi  
(17.23 MPa, 172.36 bar)  
VALVE, pressure relief, 3000 psi  
(20.68 MPa, 206.84 bar)  
Also order Ref 27, Part No. 123025 and Ref 60, Part  
No. 16D984  
† Also order Ref. 57, Part No. 117156 when ordering  
this part.  
Fuses  
Pressure Relief Valves  
Important Information regarding Pressure Relief  
Valve 16C807.  
Part  
Description  
Qty  
1
571039 FUSE, 12 volt DC  
571040 FUSE, 24 volt DC  
Pressure Relief Valve 16C807 can only be used on  
the G3 Pump. It is not intended for use with any other  
products.  
1
The pressure relief valve uses a  
pressure adjustment screw (a) to  
set the pressure release point. It  
is not intended as a way to  
relieve pressure during normal  
operation, but as a protective  
measure in the event there is an  
unintended pressure increase in  
the system. Do not use this pres-  
sure relief valve a means of  
a
b
ti15644  
relieving pressure in day-to-day,  
normal cycle operation.  
a = adjustment screw  
b = locking nut  
The pressure adjustment screw  
will require periodic adjustments.  
Whenever the valve is set/adjusted (after the set point is  
found) it is important to ensure that the valve is not bot-  
tomed out and there is at least 1/2 turn of adjustment  
remaining. This is determined by turning the screw (a)  
1/2 turn and then back turning it out again.  
30  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Installation and Repair Kits  
Manual  
Number  
Kit No.  
Description  
571026 KIT, output union, 3 pump  
571063 KIT, output union, 2 pump  
3A0523  
KIT, return to reservoir NPT,  
571028 includes pressure relief valve  
16C807  
3A0525  
KIT, return to reservoir BSPP,  
571071 includes pressure relief valve  
16C807  
KIT, vent valve, 12 volt DC, NO,  
NPT DEU  
24M478  
KIT, vent valve, 24 volt DC, NO,  
NPT DEU  
24M479  
3A0526  
KIT, vent valve, 115 VAC, NO,  
NPT, DIN  
24M480  
24N182 KIT, vent valve, 230 VAC  
571036 KIT, cover with “G” label  
NA  
KIT, pump element, includes Ref  
17, 18, 33  
571041  
3A0533  
KIT, repair, 2 liter reservoir,  
includes Ref 13, 36, 40  
571042  
3A0534  
KIT, repair, 2 liter reservoir, for  
571069 models with follower plate,  
includes Ref 13, 36, 40  
KIT, replacement, paddle, 2 liter,  
571044 for models without follower plate,  
includes Ref 13, 16, 35, 57  
KIT, replacement, paddle, 2 liter,  
for models with follower plate,  
includes Ref 13, 16, 35,40a, 42,  
571045  
57  
3A0535  
KIT, replacement, paddle, 4-16  
571046 liter, for models without follower  
plate, includes Ref 13, 16, 35, 57  
KIT, replacement, paddle, 4 liter,  
571047 for models with follower plate,  
includes Ref 13, 16, 35, 57  
571058 KIT, output adapter, NPT  
571070 KIT, output, adapter, BSPP  
571060 KIT, fill, zerk, leakproof  
3A0522  
NA  
KIT, repair, reservoir oil, 2 liter  
models, includes Ref 13, 36, 40b  
571179  
KIT, repair, reservoir, oil 4 liter  
models, includes Ref 13, 36, 40b  
571182  
3A0534  
KIT, repair, reservoir, grease, 4  
571183 liter models, includes Ref 13, 36,  
40b  
332291C  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
Technical Data  
Maximum Working Pressure  
Power  
5100 psi (35.1 MPa, 351.6 bar)  
100-240 VAC  
88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz,  
Single phase, inrush/locked rotor, max 40A (1ms)  
12 VDC  
9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A  
18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A  
24 VDC  
Outputs - Low Level (Dry Contact)  
Contact Rating  
Switch Rating  
Switching Current  
Carry Current  
Fluid  
10 Watts Maximum  
200 VDC Maximum  
0.5 A Maximum  
1.2 A Maximum  
Grease Models  
Oil Models  
Grease NLGI 000 - #2  
At least 40 cSt oil.  
Up to 3  
Pumps  
3
3
Pump Output  
0.12 in. (2 cm ) / minute per outlet - 2 spacers  
3
3
0.18 in. (3 cm ) / minute per outlet - 1 spacer  
3
3
0.25 in. (4 cm ) / minute per outlet - 0 spacers  
1/4-18 NPSF. Mates with 1/4-18 NPT male fittings  
2, 4, 8, 12, 16 Liters  
Pump Outlet  
Reservoir Size  
IP Rating  
IP69K  
Ambient Temps  
-40°F - 158°F (-40°C to 70°C)  
Weight (Dry - includes power cord and plug)  
Without follower plate  
With follower plate  
Wetted Parts  
13.3 lbs (6.03 kg)  
14.2 lbs (6.44 kg)  
nylon 6/6 (PA), amorphous polyamide, T5004-060, zinc  
plated steel, carbon steel, alloy steel, stainless steel,  
nitrile rubber (buna-N), bronze, nickel plated alnico,  
chemically lubricated acetal, aluminum, PTFE  
Sound Data  
<60 dB  
Dimensions  
Depth  
Height  
Width  
Model  
Inches  
Inches  
cm  
cm  
Inches  
cm  
2L  
4L  
8L  
12L  
16L  
13.25  
14.50  
18.50  
23.00  
27.50  
33.65  
36.83  
47.00  
58.42  
69.85  
8.00  
9.25  
9.25  
9.25  
9.25  
20.32  
23.50  
23.50  
23.50  
23.50  
9.00  
10.00  
10.00  
10.00  
10.00  
22.86  
25.40  
25.40  
25.40  
25.40  
32  
332291C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Technical Data  
Mounting Pattern  
(For correct mounting configuration, choose either Option 1 or Option 2). See P/N 126916 template.  
Option 1  
0.367inch  
9.3 mm  
7.087 inch  
180.0 mm  
2x Ø 0.366 inch  
1.180 inch  
30.0 mm  
9.3 mm  
3.268 inch  
83.0 mm  
3.544 inch  
90.0 mm  
Option 2  
0.722 inch  
18.3 mm  
6.378 inch  
162.0 mm  
2x Ø 0.366 inch  
9.3 mm  
0.708 inch  
18.0 mm  
3.740 inch  
95.0 mm  
3.189 inch  
81.0 mm  
FIG. 22  
332291C  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Graco Standard Warranty  
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in  
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty  
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by  
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written  
recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty  
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of  
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with  
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or  
maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of  
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned  
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs  
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT  
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy  
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or  
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.  
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT  
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to  
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these  
warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or  
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the  
negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,  
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la  
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite  
de ou en rapport, directement ou indirectement, avec les procédures concernées.  
Graco Information  
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.  
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
Original instructions. This manual contains English. MM 332291  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA  
Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.  
revised February 2015  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   

Graco Car Seat PD268712B User Manual
Grizzly Planer G1021Z User Manual
Hasbro Robotics 83850 User Manual
Honeywell Thermostat TRV15AHC User Manual
HP Hewlett Packard Digital Camera EOS30DBODY User Manual
HP Hewlett Packard Network Router Wireless Device User Manual
HP Hewlett Packard Printer 200T User Manual
HP Hewlett Packard TV Converter Box 8566A User Manual
Husqvarna Lawn Mower 1000 14 User Manual
Husqvarna Lawn Mower 2354GXLS User Manual