Instructions
G3 Standard Automatic
Lubrication Pump
332291C
EN
For dispensing of NLGI Grades #000 to #2 greases and oil with at least 40cSt. For
Professional Use Only.
Not approved for use in explosive atmospheres or hazardous locations.
Part Nos., page 3
5100 psi (35.1 MPa, 351.6 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
TI14705
Conforms to ANSI/UL 73
Certified to CAN/CSA
Std. 22.2 No 68-09
3132066
Download from Www.Somanuals.com. All Manuals Search And Download.
Part / Model Numbers
Part / Model Numbers
The Part Number is a six-digit unique number that is only used to order the G3 Pump. Directly related to this six digit
Part Number is the configured Graco Model Number. This configured number identifies the distinct features of a spe-
cific G3 Pump. To help you understand each component that makes up the Model Number see Understanding Your
Model Number, page 4. The tables below shows the relationship between each Part Number and its related Model
Number.
2 Liter Models
8 Liter Models
Part
Numbers
Part
Model Number
Model Number
Numbers
96G039
96G041
96G000 G3-G-12NC-2L0000-00C00000
96G001 G3-G-24NC-2L0000-00C00000
96G002 G3-G-ACNC-2L0000-0D000000
96G003 G3-G-12NC-2L0A00-L0C00000
96G005 G3-G-24NC-2L0A00-L0C00000
96G006 G3-G-24NC-2FA00-L0C00000
96G007 G3-G-ACNC-2L0A00-LD000000
96G008 G3-G-ACNC-2LFA00-LD00000
96G050 G3-A-24NC-2L0A00-L0C00000
96G059 G3-A-ACNC-2L0A00-LD000000
96G182 G3-G-24NC-2L0A00-0D00L000
G3-G-12NC-8L0000-00C00000
G3-G-24NC-8L0000-00C00000
G3-G-ACNC-8L0000-0D000000
G3-G-12NC-8L0A00-L0C00000
G3-G-24NC-8L0A00-L0C00000
G3-A-24NC-8L0A00-L0C00000
G3-G-ACNC-8L0A00-LD000000
G3-A-ACNC-8L0A00-LD000000
G3-G-ACNC-8LFA00-0D00L000
96G043
96G045
96G049
96G052
96G056
96G061
96G187
12 Liter Models
4 Liter Models
Part
Model Number
Numbers
Part
Model Number
Numbers
96G057
96G171
G3-G-ACNC-120A00-LD000000
G3-G-24NC-120000-00C00000
96G038 G3-G-12NC-4L0L00-00C00000
96G040 G3-G-24NC-4L0000-00C00000
96G042 G3-G-ACNC-4L0000-0D000000
96G044 G3-G-12NC-4L0A00-L0C00000
96G048 G3-G-24NC-4L0A00-L0C00000
96G051 G3-A-24NC-4L0A00-L0C00000
96G053 G3-G-24NC-4LFA00-L0C00000
96G055 G3-G-ACNC-4L0A00-LD000000
96G060 G3-A-ACNC-4L0A00-LD000000
96G062 G3-G-ACNC-4LFA00-LD000000
96G179 G3-G-ACNC-4LFA00-0D00L000
96G184 G3-G-24NC-4L0A00-0D00L000
16 Liter Models
Part
Model Number
Numbers
96G058
96G172
G3-G-ACNC-160A00-LD000000
G3-G-24NC-160000-00C00000
332291C
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Part / Model Numbers
Understanding the Model Number
Use the Code Sample provided below to identify each component’s location in the Model Number. The options for
each component that make up the code are provided on the lists below.
NOTE: Other pump configurations are available that are not documented in this manual. Contact Graco Customer
Service or your local Graco distributor for assistance.
G
3
-
G
-
N
b
C
b
0
f
0
f
0
j
0
0
0
p
Code Sample:
a
a
-
c
c
d
e
-
g
h
i
k
m n
G3 - G = Identifies pump as being a G3; G = Grease
G3 - A = Identifies pump as being a G3; A = Oil
•
0 = No Follower Plate
Code e: Low Level Option
Code aa: Power Source
•
•
A = External Low Level
0 = No Low Level monitoring
•
•
•
12 = 12 Volts DC
24 = 24 Volts DC
AC = 100 - 240 Volts AC
Code ff: Options
•
00 = No Options
Code bb: Operation Control
NC = No Controller
Code cc: Reservoir Capacity (Liters)
Code g, h, i, j, k, m, n, p
NOTE: Codes g - p relate to a specific location on the
G3 pump. See FIG. 1 for these locations.
•
•
•
•
•
•
2L = 2 Liters
4L = 4 Liters
8L = 8 Liters
12 = 12 Liters
16 = 16 Liters
•
•
•
•
C = CPC
D = DIN
L = Low Level
0 = Not populated
Code d: Follower Plate Installed
•
F = Follower Plate Installed
k
m
h
g
i
p
j
n
FIG. 1
4
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
WARNING
ELECTRIC SHOCK HAZARD
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause
electric shock.
• Turn off and disconnect power at main switch before disconnecting any cables and before servicing
or installing equipment.
• Connect only to grounded power source.
• All electrical wiring must be done by a qualified electrician and comply with all local codes and
regulations.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS from distributor or retailer.
•
•
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
•
•
•
•
•
•
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
332291C
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
•
•
•
•
Do not point dispensing device at anyone or at any part of the body.
Do not put your hand over the fluid outlet.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or
servicing equipment.
+
•
•
Tighten all fluid connections before operating the equipment.
Check hoses and couplings daily. Replace worn or damaged parts immediately.
PRESSURIZED EQUIPMENT HAZARD
Over-pressurization can result in equipment rupture and serious injury.
• A pressure relief valve is required at each pump outlet.
• Follow Pressure Relief Procedure in this manual before servicing.
PLASTIC PARTS CLEANING SOLVENT HAZARD
Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or
property damage.
•
•
Use only compatible water-based solvents to clean plastic structural or pressure-containing parts.
See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent
manufacturer’s MSDSs and recommendations.
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
•
•
•
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure and disconnect all power sources.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including
eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is
not limited to:
•
•
Protective eyewear, and hearing protection.
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer
6
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
Grounding
The equipment must be grounded. Grounding reduces the risk of electric shock by providing an escape wire
for the electrical current in the event of malfunction or breakdown. This product is equipped with a cord having
an equipment grounding conductor. The wire with insulation having an outer surface that is green with or
without yellow stripes is the grounding wire.
Component Identification
M
K
A
L
Oil Models
Grease Models
C
Grease Models with Follower
Plate
E
D
H
F
J
I
96GXXX
B
G3-G-24NC-2L0A00-L0C00000
FIG. 2:
Key:
A
B
Reservoir
H
I
Power / Sensor Panel (both sides; only one side shown)
Part Number / Model Number example only shown, (see
Power Cord (DIN shown)
Follower Plate (grease models only / not available on all
grease models)
Vent Hole for Follower Plate (grease models only / not
available on all grease models)
Fill cap (oil models only)
Adjustable Pump Element (1 included. Can accommodate 3
total)
C
Pressure Relief Valve (Not included / required for each outlet
- Available from Graco. See Parts, page 30.)
Zerk Inlet Fill Fitting (1 included / grease models only)
Pump Outlet Plug (2 included)
Volume Control Spacers (2 included. More spacers = less
output volume per stroke) (also see FIG. 13, page 19)
Fuse (DC models only - Not included, not shown. Available
from Graco. See Parts, page 30.)
J
K
D
E
F
L
M
G
332291C
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Typical Installation
Divider Installations
B
D
E
A
F
Injector Installations
E
B
H
D
F
A
G
A Connected to fuse / power
B Pressure relief valve (Not included/ required for each outlet -
user supplied. See Parts, page 30)
F - Proximity Switch (Divider Installations)
- Pressure switch (Injector Installations)
G Vent valve (Not included / available from Graco. See Parts,
D Series progressive divider valves (Divider Installations)
- Injectors (Injector Installations)
page 31.)
H Return to reservoir
E To lube points
8
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Choosing an Installation Location
AUTOMATIC SYSTEM ACTIVATION HAZARD
If the system is equipped with has an automatic timer (user supplied) that activates the pump lubrication system
when power is connected or when exiting the programming function, unexpected activation of the system could result
in serious injury, including skin injection and amputation.
Before you install or remove the lubrication pump from the system, disconnect and isolate all power supplies and
relieve all pressure.
•
•
Select a location that will adequately support
the weight of the G3 Pump and lubricant, as
well as all plumbing and electrical connections.
•
•
Always mount the G3 oil models upright.
If the G3 grease model is going to be operated
in a tilted or inverted position for any period of
time, you must use a model that includes a fol-
lower plate, otherwise the G3 must be mounted
upright. Refer to your model number to confirm
if a follower plate was installed on your pump.
to identify this character in your model number.
Refer to the two mounting hole layouts provided
in the Mounting Pattern section of this manual,
NOTE: The two mounting hole layouts provided
in the Technical Data section show the only cor-
rect installation patterns to use for mounting the
G3. No other installation configurations should
be used.
•
•
Use the three fasteners (included) to secure the
G3 to the mounting surface.
Some installations may require an additional
reservoir support bracket. Consult your Graco
distributor for assistance with this installation.
•
Use designated mounting holes and provided
configurations only.
332291C
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
System Configuration and Wiring
Fuses
NOTICE
Improper installation of the grounding conductor may
Fuses (user supplied) are required on all DC mod-
els. To avoid equipment damage:
result in a risk of electric shock. This product must be
installed by a qualified electrician in compliance with
all state and local codes and regulations.
•
Never operate G3 Pump DC models without a
fuse installed.
If the product is permanently connected:
•
A fuse of the correct voltage must be installed in
line with the power entry to the system.
•
it must be installed by a qualified electrician or ser-
viceman.
Fuse Kits are available from Graco. The following Table
identifies the correct fuse to use for your input voltage
and the corresponding Graco Kit number.
•
it must be connected to a grounded, permanent wir-
ing system.
If an attachment plug is required in the end use
application:
Input Voltage
12 VDC
Graco Kit No.
571039
Fuse Value
7.5 A
•
•
•
it must be rated for the product electrical specifica-
tions.
24 VDC
571040
4 A
it must be an approved, 3-wire grounding type
attachment plug.
Recommendations for Using Pump in
Harsh Environments
it must be plugged into an outlet that is properly
installed and grounded in accordance with all local
codes and ordinances.
•
•
Use pump with CPC style power cable.
If using a DIN style power or alarm harness with a
right angle mating connector, make sure the con-
nector does not exit the unit in the UP direction.
•
when repair or replacement of the power cord or
plug is required, do not connect the grounding wire
to either flat blade terminal.
•
Use a corrosion preventative electrical grease on all
contacts.
10
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Wiring and Installation Diagrams
The following Table identifies the wiring and installation diagrams for the cable included with the pump provided in
this manual.
Diagram
Page #
12
Symbol
Power DIN AC
Power DIN DC
Power CPC DC
13
14
Low Level Outputs
15
332291C
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Power DIN AC - 15 foot: Part No. 16U790
Pin and Related Wire Color (FIG. 3)
Pin Pin Name
Color
1
2
3
4
Line
NEUTRAL
Not Used Not Used
GROUND Green
Black
White
Connector on Housing
Connector on Cable
(4)
(4)
(2)
(1)
(1)
(2)
(3)
Example Wiring Diagram
1
2
3
4
FIG. 3
12
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Power DIN DC - 15 foot: Part No. 16U790
NOTICE
Be sure when power is applied that stirring paddle
rotates clockwise (when viewed from the top). If it is
wired incorrectly paddle could rotate counter-clockwise
which will damage the pump’s internal components. If
this happens, stop the pump immediately and wire unit
correctly.
Pin and Related Wire Color (FIG. 5)
Pin
Pin Name
Color
1
2
3
4
-VDC
+VDC
Not Used
Not Used
Black
White
Not Used
Green
FIG. 4
Connector on Housing
Connector on Cable
(4)
(4)
(2)
(1)
(1)
(2)
(3)
Example Wiring Diagram
Ignition Switch
1
2
3
4
Fuse
12V-pump - 7.5A - Graco kit #571039
24V pump - 4A - Graco kit #571040
FIG. 5
332291C
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Power CPC DC - 15 foot: Part No. 126217
Pin and Related Wire Color (FIG. 6)
Pin Pin Name
Color
1
2
3
4
5
6
7
Not Used
-VDC
+VDC
Not Used
Not Used
Not Used
Not Used
Not Used
Black
White
Not Used
Not Used
Not Used
Green
Connector on Housing
Connector on Cable
(2)
(2)
(3)
(1)
(3)
(1)
(7)
(4)
(6)
(7)
(4)
(5)
(5)
(6)
Example Wiring Diagram
1
2
3
4
5
6
7
Ignition Switch
Fuse
12V-pump - 7.5A - Graco kit #571039
24V pump - 4A - Graco kit #571040
FIG. 6
14
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Low Level Outputs
See Low Level Output Option, page 22 for functional description. See Technical Data, page 32 for ratings.
Pin Pin Name
1
2
3
4
Not Used
Not Used
LL N.O.
LL COM
Connector on Housing
Connector on Housing
(4)
(4)
(3)
(1)
(1)
(2)
(3)
(2)
Example Wiring Diagram
G3
1
2
3
4
FIG. 7
332291C
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Part No. 124333: Cable Pin Out (M12)
Part No. 124300: Field Wireable Pin Out
(M12)
Wire Colors
Item No. Color
Wire Colors
Item No. Color
1
2
3
4
Brown
White
Blue
Brown
White
Blue
1
2
3
4
Black
Black
ꢓꢉꢔꢊꢇꢋꢕꢐꢍꢋꢖꢗꢘ
ꢆꢇꢈꢉꢊꢇꢋꢌꢍꢎꢋꢏꢐꢇꢑ
ꢆꢐꢇꢊꢎꢋꢙꢐꢚꢇꢉꢔꢊꢇꢋꢕꢐꢍꢋꢖꢗꢘ
ꢀꢄꢂ
ꢆꢇꢈꢉꢊꢇꢋꢌꢍꢎꢋꢏꢐꢇꢑ
ꢀꢅꢂ
ꢀꢄꢂ
ꢀꢅꢂ
ꢀꢃꢂ
ꢀꢃꢂ
ꢀꢁꢂ
ꢒꢉꢊꢇꢋꢌꢍꢎꢋꢏꢐꢇꢑ
ꢀꢁꢂ
FIG. 9
ꢀꢄꢂ
ꢀꢃꢂ
ꢀꢅꢂ
ꢀꢁꢂ
FIG. 8
16
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Part No. 124594: 4 Pin Eurofast Field
Wireable Connector
Part No. 124595: 5 Pin Eurofast Field
Wireable Connector
ꢀꢅꢂ
ꢀꢄꢂ
ꢀꢄꢂ
ꢀꢃꢂ
ꢀꢁꢂ
ꢀꢅꢂ
ꢀꢛꢂ
ꢀꢁꢂ
ꢀꢃꢂ
FIG. 11
FIG. 10
332291C
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
Connecting to Auxiliary Fittings
Setup
Pressure Relief
Follow the Pressure Relief Procedure whenever
you see this symbol.
NOTICE
Do not attach unsupported equipment to auxiliary fit-
tings such as fill ports and pump element. Attaching
unsupported equipment to these fitting can result in
irreparable housing damage.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
•
Always use two wrenches working in opposite
directions when connecting anything to pump
element or auxiliary fittings. See FIG. 12 for an
example.
•
•
Torque pump element fittings to 50 in. lbs (5.6
N•m).
Relieve pressure in system using two wrenches work-
ing in opposite directions on pump element and pump
element fitting to slowly loosen fitting only until fitting
is loose and no more lubricant or air is leaking from fit-
ting.
When connecting pump element into housing
torque to 50 in. lbs (5.6 N•m).
Pressure Relief Valves
NOTE: When loosening pump element fitting, do NOT
loosen pump element. Loosening pump element will
change the output volume.
To prevent over-pressurization, which can result in
equipment rupture and serious injury, a pressure relief
valve appropriate for the lubrication system must be
installed close to every pump outlet to alleviate unin-
tended pressure rises in the system and protect the G3
pump from damage.
•
Only use a pressure relief valve that is rated for no
more than the working pressure of the G3 pump it
•
Install a pressure relief valve close to every pump
outlet; before any auxiliary fitting.
NOTE: A pressure relief valve can be purchased from
Graco. See Parts, page 30.
FIG. 12
18
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
3. Tighten pump element fitting. Torque fitting to 50 in.
lbs (5.6 N•m).
Setting Pump Outlet Volume
NOTE:
•
•
•
Before making any adjustments to pump volume,
Only use Graco supplied spacers to control output
volume.
It may be necessary to repeat this outlet volume
setup procedure after the pump is operating to
re-adjust the volume of dispensed fluids.
FIG. 13
1. Use a wrench to turn pump element counter-clock-
wise to loosen. Do not remove entire pump element.
Only back pump element out enough to allow
spacer to be slid on or off.
Loading Grease
To ensure optimal performance from the G3:
•
Only use NLGI #000 - #2 greases appropriate for
your application, automatic dispensing, and the
equipment’s operating temperature. Consult with
machine and lube manufacturer for details.
2. If needed, remove or insert spacers to achieve
required pump output volume. A tool may be
needed to facilitate removal.
•
The reservoir can be filled using a hand operated
pump, pneumatic pump or electric transfer pump.
Pump volume control is set using either no (0) spac-
ers, 1 or 2 spacers (FIG. 13).
•
•
Do not overfill (FIG. 15).
Do not use more than 2 spacers to adjust output vol-
ume.
Do not operate G3 without reservoir attached.
NOTICE
Output Volume / Minute
•
Always clean fitting (D) with a clean dry cloth
prior to filling reservoir. Dirt and/or debris can
damage pump and/or lubrication system.
No. Spacers cubic inches
cubic cm
2
1
0
0.12
0.18
0.25
2
3
4
• Care must be used when filling the reservoir
using a pneumatic or electric transfer pump to
not pressurize and break the reservoir.
NOTE:
•
The amount of dispensed volume can vary depend-
ing on external conditions such as lubricant tem-
perature and back pressure from downstream
connections.
•
•
Use of these volume adjustment in conjunction with
setting the ON time of the pump will allow for control
of the output volume.
Use these volume adjustments as a starting point
and adjust as necessary to ensure desired lubrica-
tion dispense.
332291C
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
For models using an external controller, start pump
operation per your controller specifications.
Models without a follower plate:
3. Fill reservoir with grease until seal of follower plate
breaches the vent hole (FIG. 16) and the majority of
air is expelled from the reservoir.
E
D
vent hole
FIG. 14
2. For higher viscosity fluids, start pump to rotate stir-
ring paddle during fill to prevent air pockets from
forming in grease.
FIG. 16
For models using an external controller, start pump
operation per your controller specifications.
NOTE: Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
4. Remove fill hose.
3. Fill reservoir with NLGI grease to max fill line.
NOTE: Vent port, located in rear of reservoir, should not
be used as an overfill port/indicator.
Changing Greases
When changing greases, always use compatible fluids
or greases.
max fill line
FIG. 15
4. Remove fill hose.
Models with a follower plate:
2. For higher viscosity fluids, start pump to rotate stir-
ring paddle during fill to prevent air pockets from
forming in grease.
20
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup
Filling Oil Unit
•
Only use oil appropriate for your application, auto-
matic dispensing, and the equipment’s operating
temperature. Consult with machine and lube manu-
facturer for details.
•
The reservoir can be filled using a hand operated
pump, pneumatic pump or electric transfer pump.
•
•
•
Do not overfill (FIG. 17).
Do not operate G3 without reservoir attached.
Only use oils with viscosity at least 40 cSt.
FIG. 18
2. Only run pump until air is no longer dispensed with
the lubricant coming out of element fitting (FIG. 19).
a
b
FIG. 17
1. Remove fill cap (a).
2. Pour oil into reservoir to fill line (b).
3. Replace fill cap. Hand tighten cap, securely.
FIG. 19
3. Tighten pump element fitting using two wrenches
working in opposite directions (FIG. 18).
Priming
NOTE: It is not necessary to prime pump every time
pump is filled with lubricant.
Pump only requires priming the first time it is used or if it
is allowed to run dry.
1. Loosen pump element fitting (FIG. 18).
NOTE: When loosening pump element fitting, do NOT
loosen pump element. Loosening pump element will
change the output volume
332291C
21
Download from Www.Somanuals.com. All Manuals Search And Download.
No Controller Operation
No Controller Operation
The G3 Pump can be controlled using an external, user
supplied, power source and controller.
Low Level Output Option
Some G3 pumps without controllers include a Low Level
Output Option. It can be configured with an M12 con-
nector in code location “G” or with a DIN connector in
code location “K”. (See Understanding the Model Num-
PINS 3 and 4. For PIN 3 and 4 locations and wiring
information the Low Level Outputs diagram, page 15.
Refer to the Typical Installation diagrams provided on
page 8 for correct location of the required pump ground
wire and fuses.
NOTE:
•
•
When using an external power source and control-
ler, Pump ON (Run) Time should be set for no lon-
ger than 30 minutes.
NOTE: A low level warning is triggered when the con-
troller detects PINS 3 and 4 have momentarily closed.
In most cases, Pump OFF (Rest) Time should be
twice as long as Pump ON (Run) time. If alternative
ON / OFF times are required, contact Graco Cus-
tomer Service for assistance.
Grease Pumps
When the grease level has reached a low warning level,
PINS 3 and 4 momentarily close (1 time per paddle rev-
olution) sending the signal that the fluid has reached a
low level to the controller.
To ensure that a low level condition has been met, 3 or
more low level triggers must be detected within 1 minute
or less.
See FIG. 20 for an illustration of a typical Low Level Out-
put response to low grease level.
Typical Low Level Output Response with Low Level Fluid in Grease Models
200 ms
Closed
Contact
Position
Open
3 s
FIG. 20
22
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
No Controller Operation
Oil Pumps
To ensure that a low level condition has been met, the
low level trigger must be detected for 10 continuous sec-
onds.
When the oil level has reached a low warning level,
PINS 3 and 4 close, sending the signal to the controller
that the fluid has reached a low level.
See FIG. 21 for an illustration of a typical Low Level Out-
put response to low oil level.
Typical Low Level Output Response with Low Level Fluid in Oil Models
Closed
Contact
Position
Open
FIG. 21
332291C
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Troubleshooting
Problem
Cause
Solution
Incorrect/loose wiring
Refer to Installation instructions,
Unit does not power on
Tripped external fuse due to internal
component failure
Contact Graco Customer Service.
Unit does not power on (DC models Tripped external fuse due to pump-
Replace lubricant with pumpable
lubricant, rated for environmental
conditions and application.
only)
ing non-cold weather lubricant in
cold weather -13°F (-25°C)
Replace fuse.
Unit does not power on (AC models Tripped internal power supply fuse
Contact Graco Customer Service.
Replace reservoir.
only)
due to power supply failure
Reservoir retaining tabs are
cracked or broken
Lubricant leaks past seal located on Reservoir is being pressurized
Ensure vent hole is not plugged.
the bottom of the reservoir
during filling
If problem persists, contact Graco
Customer Service or your local
Graco distributor for assistance.
Unit not pumping during ON cycle,
but external controller functions
Failed motor
Replace unit.
Air is trapped in the reservoir
Add grease following Loading
Follower plate is not going down
cant Ensure air is purged.
Pump takes several minutes before Pumping non-cold weather lubricant Add 1 stroke adjust spacer and
it begins pumping at the highest
pump volume setting (no stroke
adjust spacers installed)
in cold weather -13°F (-25°C)
adjust lube cycle time to accommo-
date the difference in pump volume
per stroke.
In an Injector System without sen-
sor feedback, unit does not vent
properly
Vent valve time needs to be config- Adjust external vent valve control
ured time.
24
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Maintenance
Frequency
Component
Zerk Fittings
Required Maintenance
Keep all fittings clean using a clean
dry cloth. Dirt and/or debris can dam-
age pump and/or lubrication system.
Daily and at refill
Daily
G3 Pump Unit and Reservoir
External Wiring Harness
Keep pump unit and reservoir clean
using a clean dry cloth.
Monthly
Verify external harnesses are
secure.
332291C
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts - 2 Liter Models
Parts - 2 Liter Models
40b
Follower Plate
Models Only
Low Level Grease Models Only
45
40a
43
44
42
35
57
27
1
41
16
36
60
23
13
15
Low Level Oil Models Only
67
12
14
18
37
3
21
66
1
33
17
3
1
2
3
Torque to 4 in. lbs (0.45 N.m)
Torque to 30 in. lbs (3.4 N.m)
Torque to 50 in. lbs (5.6 N.m)
3
2
4
26
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts - 4 Liter and Larger Models
Parts - 4 Liter and Larger Models
Follower Plate
Models Only
40a
40b
43
44
Low Level Grease Models Only
45
41
36
42
35
57
27
1
61
16
62
13
60
23
15
12
14
18
Low Level Oil Models Only
67
3
37
1
21
17
33
66
3
1
2
3
Torque to 4 in. lbs (0.45 N.m)
Torque to 30 in. lbs (3.4 N.m)
Torque to 50 in. lbs (5.6 N.m)
3
4
2
332291C
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
Ref
Part
Description
Qty
Ref
1
Part
Description
BASE, three pump housing
Qty
1
PADDLE, low level, models
96G003-96G008, 96G038,
96G044, 96G045, 96G048,
3
278142 COVER, bottom, with seal
1
23
278136 96G049, 96G053,
96G055-96G058, 96G062,
1
4
115477 SCREW, mach, torx pan hd
RECT-RING, included in kit
9
96G179, 96G182, 96G184,
96G187
SCREW, M6, models
96G003-96G008, 96G038,
96G044, 96G045, 96G048,
12 127079
1
2
571042, 571069, 571179
O-RING, 258, included in Kit
13 124396 571042, 571044, 571045, 571069,
571179
27 123025 96G049, 96G053,
96G055-96G058, 96G062,
1
1
14
15
PLATE, ricer
1
1
96G179, 96G182, 96G184,
96G187
BEARING, ball
33
PADDLE, stirring, 2 Liter models
without follower plate - models
96G000, 96G001, 96G002,
96G003, 96G005, 96G007,
96G182, included in Kit 571044,
PADDLE, stirring, 4 Liter models
without follower plate - models
96G038, 96G040, 96G042,
96G044, 96G048, 96G055,
96G184
16A579 LABEL, safety
1
WIPER, stirring, models without
follower plate - models 96G000,
96G001, 96G002, 96G003,
96G005, 96G007,
96G038-96G045, 96G048,
96G049, 96G055-96G058,
96G171, 96G172, 96G182,
96G184, included in Kit 571044
WIPER, stirring, models with fol-
lower plate - models 96G006,
96G008, 96G053, 96G062,
96G179, 96G187, included in Kit
571045
35
1
1
1
PADDLE, stirring, 8 Liter models
without follower plate - models
96G039, 96G041, 96G043,
96G045, 96G049, 96G056
1
16
PADDLE, stirring, 12 Liter models
without follower plate - model
96G057, 96G171
PADDLE, stirring, 16 Liter models
without follower plate - model
96G058, 96G172
1
1
36
LABEL, brand
1
1
FITTING, zerk, grease, not
37 123741 included on models
96G050-96G052, 96G059-96G061
RESERVOIR, 2 liter, grease,
40a 24E984 96G000-96G008, 96G182,
included in Kit 571042, 571069
PADDLE, stirring, 2 Liter models
with follower plate - models
96G006, 96G008, included in Kit
571045
PADDLE, stirring, 4 liter models
with follower plate - models
96G053, 96G062, 96G179
1
1
1
RESERVOIR, 2 liter, oil, 96G050,
96G059, included in Kit 571179
40b 16G021
RESERVOIR, 4 liter, grease,
96G038, 96G040, 96G042,
1
1
40a 24B702 96G044, 96G048, 96G053,
96G055, 96G062, 96G179,
1
1
PUMP, element, included in Kit
571041
17
96G184, included in Kit 571183
RESERVOIR, 4 liter, oil, 96G051,
SPACER, stroke adjust, included
in Kit 571041
18 16F368
2
2
40b 16G020
96G060
21 278145 PLUG, pump, 3/4-16
28
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Ref
Part
Description
Qty
Ref
Part
Description
Qty
RESERVOIR, 8 liter, grease,
96G039, 96G041, 96G043,
96G045, 96G049, 96G056,
96G187
LABEL, models 96G002, 96G007,
96G008, 96G042, 96G043,
96G055-96G062, 96G179,
96G187
58
40a
1
196548
1
RESERVOIR, 8 liter, oil, 96G052,
96G061, included in Kit 571182
WASHER, low level, models
96G003-96G008,
96G033-96G038,
96G044-96G045, 96G048,
96G049, 96G053,
96G055-96G058, 96G062,
96G179, 96G182, 96G184,
96G187
40b
40a
40a
1
1
1
1
2
1
1
1
RESERVOIR, 12 liter, 96G057,
96G077, 96G171
RESERVOIR, 16 liter, 96G058,
96G172
SEAL, follower plate, 2 liter models
96G006, 96G008
60 16D984
2
278139
16F472
41
42
43
44
RESERVOIR, mid-section, 8 liter
models 96G039, 96G041,
96G043, 96G045, 96G049,
96G052, 96G056, 96G061,
96G187
RESERVOIR, mid-section, 12 liter
models 96G057, 96G171
RESERVOIR, mid-section, 16 liter
models 96G058, 96G172
SEAL, follower plate, 4 liter models
96G053, 96G062, 96G179
PLATE, follower, 2 liter models
96G006, 96G008
PLATE, follower, 4 liter models
96G053, 96G062, 96G179
1
61
62
2
3
ROD, follower plate, 2 liter models
96G006, 96G008
ROD, follower, 4 liter models
96G053, 96G062, 96G179
SPRING, compression, 2 liter
models 96G006, 96G008
ADAPTER, reservoir, models
96G038-96G045, 96G048,
96G049, 96G051-96G053,
96G055, 96G057, 96G058,
96G060-96G062, 96G171,
96G172, 96G179, 96G184,
96G187
1
1
1
SPRING, compression, 4 liter
models 96G053, 96G062, 96G179
BAFFLE, low level, 2 liter models
45† 24D838 96G003, 96G005, 96G007,
96G182
1
1
1
NUT, oil, models 96G050,
66 126417 96G051, 96G052, 96G059,
96G060, 96G061
BAFFLE, low level, 4 liter models
†
†
24E246 96G044, 96G048, 96G055,
96G184
BAFFLE, low level, 8 liter models
24F836 96G045, 96G049, 96G052,
96G056, 96G061
FLOAT, oil, models 96G050,
67 24N806 96G051, 96G052, 96G059,
96G060, 96G061
CABLE,15 ft (4.5 m), SOOW
126217 w/7pos, 3 pin, 90 deg (See Wiring
1
1
Diagram, page 14)
CABLE, DIN, bare, (See Wiring
Diagram, page 12)
200
BAFFLE, low level, 12 liter models
96G057
†
†
24F923
1
1
16U790
BAFFLE, low level, 16 liter models
96G058
24F924
BEARING, sleeve, models
96G003-96G008, 96G038,
96G044-96G045, 96G048,
57 117156 96G049, 96G053,
96G055-96G058, 96G062,
1
96G179, 96G182, 96G184,
96G187
332291C
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
NOTE: Turning adjustment screw (a) clockwise
increases pressure.
Ref
Part
Description
Qty
CABLE, M12, 15 ft., 4 wire, straight
124300 male to flying leads (See Wiring
Diagram, page 16)
1
Part
Description
Qty
201
VALVE, pressure relief, 500-3500 psi
(3.44 MPa, 34.4 bar - 24.1 MPa, 241
bar), Set pressure 3000 psi + 10%
(20.68 MPa, 206.8 bar + 10%)
Included in Kit 571028
CABLE, M12, 15 ft., 4 wire, straight
124333 male to female (See Wiring Dia-
gram, page 16)
1
16C807
1
CONNECTOR, Eurofast, fem,
straight, 4 Pin
1
1
1
124301
VALVE, pressure relief, 750 psi (5.17
MPa, 51.71 bar)
VALVE, pressure relief, 1000 psi
(6.89 MPa, 68.95 bar)
VALVE, pressure relief, 1500 psi
(10.34 MPa, 103.42 bar)
563156
563157
563158
563159
563160
563161
1
1
1
1
1
1
CONNECTOR, Eurofast, 4 Pin
(see wiring diagram, page 17)
CONNECTOR, Eurofast, 5 Pin
(see wiring diagram, page 17)
202 124594
124595
Replacement Danger and Warning labels, tags and
cards are available at no cost.
VALVE, pressure relief, 2000 psi
(13.78 MPa, 137.89 bar)
VALVE, pressure relief, 2500 psi
(17.23 MPa, 172.36 bar)
VALVE, pressure relief, 3000 psi
(20.68 MPa, 206.84 bar)
Also order Ref 27, Part No. 123025 and Ref 60, Part
No. 16D984
† Also order Ref. 57, Part No. 117156 when ordering
this part.
Fuses
Pressure Relief Valves
Important Information regarding Pressure Relief
Valve 16C807.
Part
Description
Qty
1
571039 FUSE, 12 volt DC
571040 FUSE, 24 volt DC
Pressure Relief Valve 16C807 can only be used on
the G3 Pump. It is not intended for use with any other
products.
1
The pressure relief valve uses a
pressure adjustment screw (a) to
set the pressure release point. It
is not intended as a way to
relieve pressure during normal
operation, but as a protective
measure in the event there is an
unintended pressure increase in
the system. Do not use this pres-
sure relief valve a means of
a
b
ti15644
relieving pressure in day-to-day,
normal cycle operation.
a = adjustment screw
b = locking nut
The pressure adjustment screw
will require periodic adjustments.
Whenever the valve is set/adjusted (after the set point is
found) it is important to ensure that the valve is not bot-
tomed out and there is at least 1/2 turn of adjustment
remaining. This is determined by turning the screw (a)
1/2 turn and then back turning it out again.
30
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Installation and Repair Kits
Manual
Number
Kit No.
Description
571026 KIT, output union, 3 pump
571063 KIT, output union, 2 pump
3A0523
KIT, return to reservoir NPT,
571028 includes pressure relief valve
16C807
3A0525
KIT, return to reservoir BSPP,
571071 includes pressure relief valve
16C807
KIT, vent valve, 12 volt DC, NO,
NPT DEU
24M478
KIT, vent valve, 24 volt DC, NO,
NPT DEU
24M479
3A0526
KIT, vent valve, 115 VAC, NO,
NPT, DIN
24M480
24N182 KIT, vent valve, 230 VAC
571036 KIT, cover with “G” label
NA
KIT, pump element, includes Ref
17, 18, 33
571041
3A0533
KIT, repair, 2 liter reservoir,
includes Ref 13, 36, 40
571042
3A0534
KIT, repair, 2 liter reservoir, for
571069 models with follower plate,
includes Ref 13, 36, 40
KIT, replacement, paddle, 2 liter,
571044 for models without follower plate,
includes Ref 13, 16, 35, 57
KIT, replacement, paddle, 2 liter,
for models with follower plate,
includes Ref 13, 16, 35,40a, 42,
571045
57
3A0535
KIT, replacement, paddle, 4-16
571046 liter, for models without follower
plate, includes Ref 13, 16, 35, 57
KIT, replacement, paddle, 4 liter,
571047 for models with follower plate,
includes Ref 13, 16, 35, 57
571058 KIT, output adapter, NPT
571070 KIT, output, adapter, BSPP
571060 KIT, fill, zerk, leakproof
3A0522
NA
KIT, repair, reservoir oil, 2 liter
models, includes Ref 13, 36, 40b
571179
KIT, repair, reservoir, oil 4 liter
models, includes Ref 13, 36, 40b
571182
3A0534
KIT, repair, reservoir, grease, 4
571183 liter models, includes Ref 13, 36,
40b
332291C
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
Maximum Working Pressure
Power
5100 psi (35.1 MPa, 351.6 bar)
100-240 VAC
88 - 264 VAC; 0.8 A current, 90 VA Power, 47/63 Hz,
Single phase, inrush/locked rotor, max 40A (1ms)
12 VDC
9 - 16 VDC; 5 A current, 60 W, inrush/locked rotor 12 A
18 - 32 VDC; 2.5 A current, 60 W, inrush/locked rotor 6 A
24 VDC
Outputs - Low Level (Dry Contact)
Contact Rating
Switch Rating
Switching Current
Carry Current
Fluid
10 Watts Maximum
200 VDC Maximum
0.5 A Maximum
1.2 A Maximum
Grease Models
Oil Models
Grease NLGI 000 - #2
At least 40 cSt oil.
Up to 3
Pumps
3
3
Pump Output
0.12 in. (2 cm ) / minute per outlet - 2 spacers
3
3
0.18 in. (3 cm ) / minute per outlet - 1 spacer
3
3
0.25 in. (4 cm ) / minute per outlet - 0 spacers
1/4-18 NPSF. Mates with 1/4-18 NPT male fittings
2, 4, 8, 12, 16 Liters
Pump Outlet
Reservoir Size
IP Rating
IP69K
Ambient Temps
-40°F - 158°F (-40°C to 70°C)
Weight (Dry - includes power cord and plug)
Without follower plate
With follower plate
Wetted Parts
13.3 lbs (6.03 kg)
14.2 lbs (6.44 kg)
nylon 6/6 (PA), amorphous polyamide, T5004-060, zinc
plated steel, carbon steel, alloy steel, stainless steel,
nitrile rubber (buna-N), bronze, nickel plated alnico,
chemically lubricated acetal, aluminum, PTFE
Sound Data
<60 dB
Dimensions
Depth
Height
Width
Model
Inches
Inches
cm
cm
Inches
cm
2L
4L
8L
12L
16L
13.25
14.50
18.50
23.00
27.50
33.65
36.83
47.00
58.42
69.85
8.00
9.25
9.25
9.25
9.25
20.32
23.50
23.50
23.50
23.50
9.00
10.00
10.00
10.00
10.00
22.86
25.40
25.40
25.40
25.40
32
332291C
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Mounting Pattern
(For correct mounting configuration, choose either Option 1 or Option 2). See P/N 126916 template.
Option 1
0.367inch
9.3 mm
7.087 inch
180.0 mm
2x Ø 0.366 inch
1.180 inch
30.0 mm
9.3 mm
3.268 inch
83.0 mm
3.544 inch
90.0 mm
Option 2
0.722 inch
18.3 mm
6.378 inch
162.0 mm
2x Ø 0.366 inch
9.3 mm
0.708 inch
18.0 mm
3.740 inch
95.0 mm
3.189 inch
81.0 mm
FIG. 22
332291C
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 332291
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
revised February 2015
Download from Www.Somanuals.com. All Manuals Search And Download.
|