Graco Heat Pump 309004C User Manual

Instructions/Parts List  
CycleFlo II  
Pneumatic Pump Controller  
309004C  
ENG  
Controls pump speed for precise batching, metering, and dosing of fluids at high or low  
pressures and flow rates.  
Not for use in explosive atmospheres.  
Important Safety Instructions  
Read all warnings and instructions in this manual.  
Save these instructions.  
Part No. 195265  
120 psi (0.8 MPa, 8 bar) Maximum Air Working  
Pressure  
Integrated Air Valves with Silenced Exhaust  
Infinite Cycle Rate Adjustment Between 10 and  
200 cpm  
Standard 120 VAC Power  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning Symbol  
Caution Symbol  
This symbol alerts you to the possibility of serious This symbol alerts you to the possibility of damage  
injury or death if you do not follow the instructions. to or destruction of equipment if you do not follow  
the instructions.  
Equipment Misuse Hazard  
Equipment misuse can cause the equipment to rupture or malfunction and result in serious  
injury.  
This equipment is for professional use only.  
Read all instruction manuals, tags, and labels before operating the equipment.  
Use the equipment only for its intended purpose. If you are uncertain about usage, call  
your Graco distributor.  
Other than for installation purposes do not alter or modify this equipment. Use only  
genuine Graco parts and accessories.  
Check equipment daily. Repair or replace worn or damaged parts immediately.  
Do not exceed the maximum working pressure of the lowest rated system component.  
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do  
not expose Graco hoses to temperatures above 200 F (93 C) or below 0 F (-18 C).  
Do not lift pressurized equipment.  
Comply with all applicable local, state, and national fire, electrical and safety  
regulations.  
3
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fire, Explosion, and Electric Shock Hazard  
Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous  
condition and resulting fire or explosion and serious injury.  
Ground the equipment.  
Proper grounding dissipates static electricity generated in the equipment.  
This equipment is not intended for intrinsically safe areas.  
Keep the dispense area free of debris, including solvent, rags, and gasoline.  
If there is any static sparking or you feel an electric shock while using the equipment,  
stop operating immediately. Do not use the equipment until you have identified and  
corrected the problem.  
Make sure all electrical work is performed only by a qualified electrician.  
Have any checks, installation or service to electrical equipment performed by a  
qualified electrician only.  
Make sure all electrical equipment is installed and operated in compliance with local  
and applicable codes.  
Make sure power is disconnected when servicing and repairing equipment.  
Keep liquids away from the electrical components.  
Disconnect electrical power at the main switch before servicing the equipment.  
Never exceed maximum wattage of the supply unit.  
4
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Description  
The CycleFlo II is a pneumatic pump controller that allows precise control over the cycle rate of the pump and  
therefor the flow rate.  
The pump cycle is initiated by a 120 volt signal. The pump cycle may be initiated by some other piece of equipment  
such as a timer or a pH controller. An isolation relay may be required in some installations. Always follow local and  
applicable electrical codes. The CycleFlo II will halt the pump cycle whenever the 120 volt signal is removed.  
Installation  
Electrical Connections  
An access hole with a strain relief installed has been provided for the external power connection. Due to the unique  
requirements of each installation, access holes have not been provided for the other optional external wiring  
connections such as the external air supply  
valve signal. Have a qualified electrician  
determine the proper strain relief, wire type, and  
wire size for your particular application. When  
positioning or adding access holes, be careful  
not to damage any internal components. Failure  
Fire, Explosion, and Electric Shock  
to use the proper strain relief, wire type and wire  
size can cause damage to internal components  
or personal injury.  
Hazard  
To reduce the risk of fire, explosion, or electric  
shock:  
There are three connections on the 120V input  
signal terminal block (see Fig. 1). The two right-  
hand connections are for line and neutral wires  
respectively. The left-hand connection is for a  
true earth ground.  
The power source conduit is not an  
adequate grounding for the system. The  
unit must be grounded to a true earth  
ground.  
A qualified electrician must complete all  
grounding and wiring connections and  
check the resistance.  
Refer to your local code for the  
requirements for a “true earth ground” in  
your area.  
5
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig.1 - Electrical Diagrams  
Cycle Rate  
Adjustment  
Relay  
120 Volt  
Signal  
Solenoid  
Valves  
Pneumatic Connections  
6
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The integrated air valves, have a common air inlet (1/4" NPT) port and two outlet ports A and B (1/4” Tube) toward  
the front of the unit. The exhaust is silenced with a muffler. Do not exceed 120 psi at the air inlet to the unit. Refer to  
your pump owner’s manual for the maximum air pressure limit of the pump.  
B Outlet  
Port  
Exhaust  
Muffler  
Strain Relief  
for Power  
Supply LIne  
Common  
Air Inlet  
A Outlet  
Port  
Failure to use the following recommended valve can cause damage to the unit and possible  
personal injury. Follow the pressure relief procedure in the pump manual before moving or  
servicing the pump.  
The A and B outlet ports are to be connected to the A and B ports respectively on the Husky 205, or to the two air  
valve control ports located on the air motors of pumps larger than the Husky 205. On pumps larger than the Husky  
205, a three way solenoid valve (Graco Part Number 115606 or equivalent) MUST be installed on the main air  
supply to the pump. This ensures that pressure is not generated by the pump when the controller is not operating.  
The same signal used to start the CycleFlo II controller can also control this valve.  
7
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setup & Adjustment  
Cycles Per Minute (CPM) Rate  
The pump cycle rate is adjustable to accommodate different pump sizes, varying product viscosities and product  
delivery speed. The pump cycle rate is measured in Cycles Per Minute (CPM), i.e. the number of times the pump  
performs a pump cycle in one minute. One pump cycle consists of a momentary pressurization of each one of the  
two diaphragms.  
Adjustment  
The CycleFlo II comes with a cycle rate adjustment relay  
that can be adjusted using a screwdriver to control the  
energizing and deenergizing rate of the built-in solenoid  
Electric Shock Hazard  
valves. This timer is adjustable between 10 and 200 cpm.  
Turning the screw clockwise will decrease the cycle rate  
of the pump. Turning the screw counter-clockwise will  
increase the cycle rate of the pump.  
To prevent accidental shock or  
electrocution disconnect the supply  
signal before opening the enclosure  
cover.  
Cycle rate adjustment  
screw  
8
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Priming the Pump  
Prime the pump by applying a 120 Volt signal to the controller to allow the temporary operation of the pump. This  
cycle rate may be increased or decreased to facilitate pump priming. Shut off electrical supply before making  
adjustments.  
Operation Procedures  
The controller and pump are now ready for operation. The pump will cycle at the preset rate any time a 120 Volt  
signal is supplied to the controller.  
Troubleshooting  
The following is a list of possible problems and their causes.  
Problem  
No operation at all  
Possible Cause & Remedy  
1. No power to the CycleFlo – check power source to unit.  
2. Damaged cycle rate adjustment relay – replace.  
3. No or low air supply – check air supply to make sure there is  
sufficient pressure and air available.  
4. Bad wire connections – turn off power and check wire connections  
from time delay relay to make sure they are all connected and  
seated properly.  
5. Bad solenoid valve(s) – turn off air supply and listen for ‘clicking’ on  
solenoid valves; replace valves if no ‘clicking’ is audible.  
Pump only operates on one side /  
diaphragm.  
1. Bad solenoid valve. Turn off and replace.  
2. Damaged cycle rate adjustment relay.  
9
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Cycle rate  
adjustment  
relay  
Enclosure  
Air Solenoid  
Valves  
Part No.  
Description  
-----  
Enclosure  
-----  
Emblem (not shown – on front of unit)  
115414  
115418  
Cycle rate adjustment relay  
Air Solenoid Valves (Note: two valves are required per controller)  
Optional Accessories  
Part No.  
Description  
102518  
115988  
115606  
Cord Set, Electrical  
Tube, Polyurethane, 50 ft.  
Valve, Solenoid, 110 VAC, 8.5W  
----- Not sold separately.  
10  
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Typical Installation Diagram  
CycleFlo II Controller  
Chemical  
Injector  
CycleFlo II  
Controller  
110V on/off  
Isolation Relay  
(recommended)  
Compressed Air In  
On  
Off  
Control Signal (24VDC)  
110 VAC  
Solenoid  
Valve #2  
Solenoid  
Valve #1  
Air Supply  
Solenoid Valve  
*Monitor /  
Controller  
Husky 1040  
Metering Pump  
Out  
Flow Controller  
sends an on/off  
signal (24VDC) to  
the isolation relay to  
control power to the  
CycleFlo II.  
*Flow  
Sensors  
Inline Mixers*  
TI0335  
* Provided by others  
11  
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Typical Installation Diagram  
Control ON/OFF signal  
(110VAC)  
CycleFlo II  
Controller  
Compressed Air In  
Diaphragm Pump  
(Husky 205 shown)  
*PH Controller,  
Flow Controller  
Timer, etc. sends 110  
VAC on/off signal to  
CycleFlo II  
*
Flow Sensor  
*
Provided by others  
9410A  
Technical Data  
Power Requirements:  
120Vac, 50/60 Hz, .2A, 24W  
Air Supply:  
120 psi (0.8 MPa, 8 bar) Max  
12  
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Hole Layout  
All mounting tabs  
may be placed in  
either position  
7 3/8”  
(187 mm)  
5”  
(127 mm)  
7 3/8”  
(187 mm)  
5”  
(127 mm)  
13  
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Graco Standard Warranty  
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from  
defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the  
exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of  
sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the  
equipment is installed, operated and maintained in accordance with Graco's written recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by  
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or  
substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility  
of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design,  
manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for  
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The  
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any  
defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor,  
and transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT  
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco's sole obligation and buyer's sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no  
other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to personal property,  
or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2)  
years of the date of sale.  
GRACO Makes no warranty and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection  
with accessories, equipment, materials or components sold but not manufactured by GRACO. These items sold, but not  
manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer.  
Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment  
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,  
breach of warranty, the negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings  
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties  
reconnaissent avoir convenu que la rédaction du présent document ainsi que de tous les documents, avis et procédures judiciaires  
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées sera en  
Anglais.  
Graco Phone Number  
For the latest information about Graco products, visit www.graco.com.  
TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you:  
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
This manual contains English. MM 309004  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441  
Copyright 1999, Graco Inc. is registered to ISO 9001  
Revised 09/2009  
14  
309004  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Webcam 312776F User Manual
Gravely Lawn Mower 39000 User Manual
Grizzly Biscuit Joiner G0725 User Manual
Heat Glo LifeStyle Indoor Fireplace 6000CL IPI S User Manual
Honeywell Thermostat CT87K User Manual
HP Hewlett Packard Computer Monitor D2828A User Manual
HP Hewlett Packard Printer 2420d User Manual
Huffy Fitness Equipment 104 03P N211956B User Manual
Humminbird Fish Finder 400TX User Manual
Husqvarna Chainsaw 1151438 95 User Manual