Instructions
®
5:1 Fire-Ball 300
Pump
306518ZAC
EN
For pumping non-corrosive and non-abrasive greases and lubricants only.For professional
use only.
Model No. 203872, 203857, 204254,
222087, 203876
900 psi (6.2 MPa, 62 bar) Maximum Working Pressure
180 psi (1.2 MPa, 12 bar) Maximum Air Input Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
WARNING
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-
ponent. See Technical Data in all equipment manuals.
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS from distributor or retailer.
•
•
•
Do not leave the work area while equipment is energized or under pressure.
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
•
•
•
•
•
•
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•
•
•
Read MSDSs to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
Always wear chemically impermeable gloves when spraying, dispensing, or cleaning equipment.
MOVING PARTS HAZARD
Moving parts can pinch, cut or amputate fingers and other body parts.
•
•
•
Keep clear of moving parts.
Do not operate equipment with protective guards or covers removed.
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment,
follow the Pressure Relief Procedure and disconnect all power sources.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including
eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is
not limited to:
•
•
Protective eyewear, and hearing protection.
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer
306518ZAC
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the valve firmly to
the side of a grounded metal pail, then trigger the
gun/valve.
Grounding
To ground the pump: remove the ground screw (Z) and
insert through the eye of the ring terminal at end of the
ground wire (Y). Fasten the ground screw back onto the
pump and tighten securely. Connect the other end of the
ground wire to a true earth ground. See Fig. To order a
ground wire clamp, order Part. No. 222011.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Be sure to ground all this equipment:
Pump: Use a ground wire and clamp as shown in FIG. 1.
Fluid hoses: Use only electrically conductive hoses.
Z
Y
Air compressor: Follow manufacturer’s recommenda-
tions.
FIG. 1
Fluid supply container: Follow the local code.
G
F
A
C
A
N
D
A
S
E
P
J
B
R
H
DETAIL A
L
M
K
1/2 in. (13 mm) between
foot spacer and bottom of
drum
FIG. 2: Typical Installation
Key:
A
Bleed-type master air valve (required if quick-disconnect
fitting [L] and coupler [M] are not installed) Order Part No.
107142
Air line filter
Air regulator and gauge
Pump runaway valve
Air inlet
Ground wire (required) Order Part No. 222011
Pump (model 204254 shown)
H
J
K
L
M
N
P
R
S
Drain valve (required) Order Part No. 210658
Dispensing valve
Low-level cut-off valve
Male quick-disconnect fitting
Female quick-disconnect coupler
Air line lubricator
B
C
D
E
F
Fluid hose
Thermal relief kit (required) Order Part No. 237893
Bung adapter, models 204254 and 222087
G
4
306518ZAC
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
1. Install the pump on the drum cover so that the
pump’s fluid intake is 1/2 inch. (13 mm) off the bot-
1. Install a pump runaway valve (D) to shut off the air
to the pump if the pump accelerates beyond the
pre-adjusted setting. A pump that runs too fast can
be seriously damaged.
2. On Models 204254 and 222087, screw the bung
adapter tightly into the drum cover’s bung hole,
adjust the position of the pump in the drum, and
tighten the bung adapter screw to hold the pump,
NOTICE
Never allow the pump to run dry of fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly damaging itself, and it may get very
hot.
System Accessories
Refer to FIG. 2 for the following instructions.
2. Install an air line lubricator (N) for automatic air
motor lubrication.
3. Install a bleed-type master air valve (A) to relieve air
trapped between the valve and the motor. As an
alternative, you can install an air line quick-discon-
nect coupler (M) and fitting (L) to serve as an
Four accessories are required in your system: an air
shut-off valve/air bleed device, fluid drain valve,
thermal relief kit, and ground wire. These accessories
help reduce the risk of serious bodily injury, including
fluid injection, splashing in the yes or on the skin,
injury from moving parts if you are adjusting or repair
the pump, and explosion from static sparking.
4. Install a Thermal Relief Kit (K) on the dispensing
valve side of the pump.
5. Install the air regulator (C) to control pump speed
and pressure.
• The air bleed device relieves air trapped between it
and air motor after the air supply is shut off.
Trapped air can cause the motor to cycle
unexpectedly, causing serious injury if you are
adjusting or repairing the pump. Use either a
bleed-type master air valve (A) or a
6. Install an air line filter (B) to remove harmful dirt and
contaminants from the compressed air supply.
Install another bleed-type master air valve (A) to iso-
late the accessories for servicing.
quick-disconnect coupler (M) and fitting (L). Install
them near the pump air inlet within easy reach from
the pump.
7. Install a drain valve (H) near the pump fluid outlet.
8. Install a suitable fluid hose (P) and dispensing valve
(J).
• The fluid drain (H) assists in relieve fluid pressure
in the displacement pump, hoses, and dispensing
valve. Triggering the valve to relieve pressure may
not be sufficient.
• The thermal relief kit (R) assists in relieving
pressure in the pump, hose, and dispensing valve
due to heat and expansion.
• The ground wire (F) reduces the risk of static
sparking.
NOTICE
Do not hang the air accessories directly on the air
inlet (E). The fittings are not strong enough to support
the accessories and may break. Provide a bracket on
which to mount the accessories.
NOTE: Install the air line accessories in the order shown
306518ZAC
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
5. If your pump accelerates quickly or is running too
fast, stop it immediately and check the fluid supply. If
the supply container is empty and air has been
pumped into the lines, prime the pump and lines
with fluid, or flush it and leave it filled with a compat-
ible solvent. Be sure to eliminate all air from the fluid
lines.
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
NOTICE
Never allow the pump to run dry of the fluid being
pumped. A dry pump will quickly accelerate to a high
speed, possibly damaging itself, and it may get very
hot.
NOTE:
1. Close the pump air regulator and bleed-type master
air valve (required in the system).
•
The low-level cut-off valve accessory (K) closes
the pump fluid intake when the fluid level is low,
which prevents air from entering the system.
A pump runaway valve (D) should be installed
on the air line to automatically shut off the pump
if it starts to run too fast.
2. Hold a metal part of the dispensing valve firmly to a
grounded metal waste container and trigger the
valve to relieve the fluid pressure.
•
Start and Adjusting the Pump
6. Read and follow the instructions supplied with each
component in the system.
7. If the pump will be unattended for any period of
time, if there is an air supply interruption, or at the
end of the work shift, shut off the system and always
relieve the pressure. (See Pressure Relief Proce-
dure)
1. With the air regulator (C) closed, open the
bleed-type master air valves (A), or, if so equipped,
join the quick-disconnect coupler (M) to the male fit-
ting (L).
2. Open the dispensing valve (J) into a grounded metal
waste container, making firm metal-to-metal contact
between the container and valve.
3. Open the pump air regulator (C) slowly, just until the
pump is running. When the pump is primed and all
air has been pushed out of the lines, close the dis-
pensing valve.
NOTE: When the pump is, and with sufficient air sup-
plied, the pump starts when the dispensing valve is
opened and shuts off when closed.
4. Adjust the air regulator until you get sufficient flow
from the dispensing valve. Always run the pump at
the lowest pressure necessary to get the desired
results. Do not exceed the maximum working pres-
sure of any component in the system.
6
306518ZAC
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Troubleshooting
checking or repairing gun.
2. Check all possible problems and causes before dis-
assembling gun.
Problem
Cause
Solution
Inadequate air supply pressure or
restricted air lines
Increase air supply and/or clear
restriction
Closed or clogged valves
Open and/or clear
Clogged fluid lines, hoses, valves,
etc.
Pump fails to operate
Relieve pressure. Clear obstruction
Assess damage and service air
motor
Damaged air motor
Exhausted fluid supply
Refill and reprime or flush
Worn or damaged air motor gasket
or seal
Asses wear or damage and service
air motor
Continuous air exhaust
Erratic pump operation
Exhausted fluid supply
Refill and reprime or flush
Clear and service
Held open or worn intake valve or
piston packings
Pump operates, but output low on
upstroke
Held open or worn piston packings
Held open or worn intake valve
Clear and service
Clear and service
Pump operates, but output low on
downstroke
Inadequate air supply or restricted
air line
Increase air supply and /or clear
restriction
Closed or clogged valves
Exhausted fluid supply
Open and/or clear
Pump operates, but output low on
both strokes
Refill fluid supply and reprime pump
or flush
Clogged fluid lines, hoses, valves,
etc.
Relieve pressure. Clear obstruction
306518ZAC
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
Service
11. Clamp the flats of the fluid piston (110) in a vise,
and torque the displacement rod (8) to the piston to
40 to 60 ft-lbs (54 to 81 N.m).
Displacement Pump Service
12. Clamp the air motor base (5) in a vise horizontally
by closing the vise jaws on the flange.
Pump Repair Kit 238286 is available and includes repair
parts for the pump and air motor. Use all parts in the kit
for best results.
13. Use a strap wrench to screw the displacement
pump cylinder (105) to the air motor base (5), and
torque to 95 to 105 ft-lbs (129 to 142 N.m).
1. Flush the pump.
14. If the ground wire was disconnected before servic-
ing, be sure to reconnect it before you operate the
pump.
2. Relieve the pressure before proceeding, page 6.
3. Disconnect the hoses, remove the pump from its
mounting, and clamp the air motor base (5) in a vise
horizontally by closing the vise jaws on the flange.
Air Motor and Throat Service
4. Unscrew the intake valve body (107) from the fluid
cylinder (105). Disassemble the intake valve. (See
Parts Drawing Page 12.) Clean and inspect the
parts for wear or damage, and replace parts as
needed. be sure to check the o-ring (108). Unless
further intake valve service is needed, reassemble
and reinstall, using liquid sealant on the male
threads.
Pump Repair Kit 238286 is available and includes repair
parts for the pump and air motor. Use all parts in the kit
for best results.
5. Use strap wrench on the fluid cylinder (105) to
screw it out of the air motor base (5). Carefully
inspect the smooth inner surface on the cylinder for
scoring or irregular surfaces. Such damage causes
premature packing wear and leaking, so replace the
part if it is damaged.
Two accessory tools should be used: Padded Pliers,
207579, are used to grip the trip rod without damaging
its surface; Gauge, 171818, is used to ensure the proper
clearance between the poppets and seat of the transfer
valve.
6. Using wrenches on the flats of the displacement rod
(8) and on the flats of the fluid piston (11), unscrew
the fluid piston from the displacement rod.
Disassembly
1. Flush the pump.
7. Take the ball (111) out of the displacement rod (8),
and take the packing o-ring (104) off of the fluid pis-
ton.
2. Relieve the pressure, see page 6.
3. Disconnect the ground wire from the grounding
screw (5a), disconnect the hoses, remove the pump
from its mounting, and clamp the air motor base in a
vise horizontally by closing the vise jaws on the
flange.
8. Clean and inspect all parts. Use all the repair kit
parts during reassembly and replace other parts as
necessary.
9. Place the piston ball (109) in the displacement rod
(8).
4. Use a strap wrench on the fluid cylinder (105) to
screw it out of the air motor base (5).
10. Install the new packing o-ring (104) on the fluid pis-
ton (110).
5. Pull the displacement rod (8) down as far as it will
8
306518ZAC
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
6. Using wrenches on the flats of the displacement rod
(8) and on the flats of the fluid piston (110), unscrew
the fluid piston from the displacement rod. Remove
the ball (111) from the end of the displacement rod,
and remove the packing o-ring (104) from the fluid
piston.
29
17
11
7. Clamp the air motor upright in the vise by closing
the vise jaws below the flange.
24
10
1
2
8. Unscrew the cylinder cap nut (29) from the top of
the air motor cylinder (17).
5a
9
21
9. Pull up on the cylinder cap nut (29) to expose the
trip rod, grasp the trip rod with padded pliers, and
unscrew the cylinder cap nut from the trip rod.
6
5
flange
8
NOTICE
Do not damage the plated surface of the trip rod (11).
Damaging the surface of the trip rod can result in
erratic air motor operation. Use the special padded
pliers to grasp the rod.
FIG. 3
13. Remove the o-ring (24) from the air motor piston (2).
10. Remove the six screws (21) holding the air motor
cylinder (17) to the air motor base (5), and carefully
pull the cylinder straight up off the piston (2).
14. Clamp the displacement rod upright in the vise by
closing the vise jaws on the flats of the displace-
ment rod.
NOTICE
15. Use a screw driver to push down on the trip rod
yoke (22) to snap the toggles (M) down. (FIG. 4)
To avoid damaging the cylinder wall, lift the cylinder
straight up off the piston. Never tilt the cylinder while
you are removing it.
16. Remove the lockwires (31) from the adjusting nuts
(30) of the transfer valves. Screw the top nuts off.
Screw the valve poppet (1) stems out of the grom-
mets (12) and bottom nuts (30). Take the valve pop-
pets off the stems and squeeze them firmly to check
for cracks.
11. Pull the air motor piston/displacement rod assembly
(2, 8) clear of the air motor base (5) by pulling up on
the air motor piston.
12. Remove the o-rings (9, 112) and u-cup packing (6)
from the air motor base (5). Use needle-nose pliers
to remove the u-cup packing from the bottom of the
air motor base.
17. Grip the toggle rockers (26) with pliers. Compress
the springs (27) and swing the toggle assembly (M)
up and away from the piston lugs (L), and remove
the assembly. Check that the valve, actuator (13) is
support by the spring clips (14), but slides easily into
18. Remove the trip rod yoke (22), actuator (13), and
trip rod (11). Check the exhaust valve poppets (16)
for cracks.
19. To remove the exhaust valve poppets (16), stretch
them out and cut them with a sharp knife.
306518ZAC
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
NOTE: Adjust the distance between the inlet valve pop-
pets and the piston seat by turning the top valve nuts
(30).
Reassembly
1. Clean all the parts carefully in a compatible solvent,
and inspect for wear or damage. Use all the repair
kit parts during reassembly, and replace other parts
as needed.
11. Tighten the bottom valve nuts (30) by hand. The
grommets (12) should be slightly compressed.
2. Check the polished surfaces of the piston (2), dis-
placement rod (8), and cylinder (17) wall for
scratches or wear. A scored rod causes premature
throat seal wear and leaking.
12. Align the holes in the valve nuts (30) and the slots
on the stems of the inlet valve poppets (1), and drop
the lock wires (31) through the holes in the valve
nuts and into the slots in the stems of the inlet valve
poppets. Pull the lock wires down tightly, and bend
the ends with pliers so that they cannot be pulled
back out of the holes.
3. Lubricate all parts with a light, water-resistant
grease.
4. Clamp the displacement rod (8) upright in the vise
by closing the vise jaws on the flats of the displace-
ment rod.
NOTICE
Never re-use the old lock wires. They will get brittle
and break easily from too much bending.
5. Pull the exhaust valve poppets (16) into the value
actuator (13), and clip off the top part shown with
13. Take the assembly out of the vise so that you can
move it around for the next two steps.
6. Install the new grommets (12) in the actuator (22),
place the inlet valve poppets (1) in the piston, and
thread the bottom valve nuts (30) onto the stems of
the inlet valve poppets until there are a few threads
left before the threads run out.
14. Grease and install the new o-rings (9, 24, 112).
15. Install the new u-cup packing (6) through the bottom
of the air motor base, with the lips facing toward the
bottom of the pump.
NOTE: If you thread the valve nuts too far down onto the
poppets, they will run off of the threaded part of the pop-
pets.
16. Slide the displacement rod (8) down through the
packings, and lower the air motor piston (2) into the
air motor base (5).
7. Grease heavily and place the trip rod (11) in the air
motor piston (2), place the actuator (13) in the yoke
(22), and place the well-greased actuator/yoke
assembly in the piston with the trip rod going
through the center holes of the actuator and yoke
and the stems of the inlet valve poppets (1) going
through the grommets (12).
17. Clamp the air motor upright in the vise by closing
the vise jaws below the flange.
18. Carefully lower the air motor cylinder (17) straight
down onto the piston assembly (2). Tighten the six
screws (21) holding the air motor cylinder to the air
motor base (5).
8. Thread the top of valve nuts (30) onto the stems of
the inlet valve poppets (1) until one thread of the
inlet valve poppets is exposed above the valve nuts.
NOTICE
To avoid damaging the cylinder wall, lower the cylin-
der straight down onto the piston. Never tilt the cylin-
der as it is being lowered.
9. Install the pins (23) in the yoke (22), place the toggle
arm (25) ends of the toggle assembly (M) onto the
toggle pins, and snap the pivot pin (26) ends of the
toggle assembly into the piston lugs (L).
19. Pull the trip rod (11) so it is sticking up out of the air
motor cylinder (17).
10. Measuring with the gauge create 0.145 inch (3.7
mm) of clearance between the inlet valve poppets
(1) and the piston seat when the inlet valve is open.
NOTE: You may have to hold the unit upside down to
shake the trip rod loose.
10
306518ZAC
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
20. Grip the trip rod (11) with padded pliers, screw the
cylinder cap (29) onto the trip rod, push the cylinder
cap nut down, and screw it into the top of the cylin-
der.
23. Clamp the flats of the fluid piston (11) in a vise, and
torque the displacement rod (8) to the piston to 40 to
60 ft-lbs (54 to 81 N.m).
24. Clamp the air motor base (5) in a vise horizontally
by closing the vise jaws on the flange.
NOTICE
Do not damage the plated surface of the trip rod (11).
Damaging the surface of the trip rod can result in
erratic air motor operation. Use the special padded
pliers to grasp the rod.
25. Use a strap wrench to screw the displacement
pump cylinder (105) to the air motor base (5), and
torque to 95 to 105 ft-lbs (129 to 142 N.m).
26. Before remounting the pump, connect an air hose
and run the air motor slowly, starting with just
enough air pressure to make the air motor run, and
make sure it operates smoothly.
21. Place the piston ball (109) in the displacement rod
(8).
22. Clean the threads of the fluid piston (110), apply
27. Reconnect the ground wire before you resume regu-
lar pump operation.
®
Loctite to the threads, install the new packing
o-ring (104) on the fluid piston, and thread the fluid
piston onto the displacement rod (8).
11 22
25
27
26
2
M
31*
30*
1*
11
1
16*
14
1*
12*
13
30*
3
L
12*
30*
24*
1*
2
4
5
1*
2
14
30*
16*
Push toggles (M) in and then up.
Cut off tops of poppets as indicated by dotted lines.
Turn wires up.
1
2
3
0.145 in (3.7 mm) clearance between poppets (1) and seat when it is open.
4
FIG. 4
306518ZAC
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
Air Motor
Pump
29
28
112*
17
105
118b
22
118a
23
25
27
26
111
110
31*
30*
13
104*
108*
106
11
15
14
16*
12*
30*
109
2
24*
107
1*
33
8
114, 115,
116, or 117
9*
10
18**
113
21
5a
5
6*
1
**20
**19
1
Lips face down.
12
306518ZAC
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Model 203857, Series N, 55 gal.
Includes items 101 to 114
Model 203872, Series N, 16 gal.
Includes items 101 to 113 and 115
Model 203876, Series N, Universal
Includes items 101 to 112
Model 204254, Series S, 55 gal. Bung Mount
Includes items 101 to 113, 116, and 118
Model 222087, Series E, 275 gal. Bung
Mount
Ref.
Part Description
158360 YOKE, rod, trip
158362 PIN, toggle
Qty.
22
23
24
25
26
27
28
29
30
31
33
1
2
1
2
2
2
1
1
4
2
1
◆
O-RING, nitrile rubber
160623 ARM, toggle
158364 ROCKER, toggle
167585 SPRING, helical compression
156698 O-RING, buna-N
161435 NUT, cylinder, cap
◆
◆
NUT, adjusting
LOCK WIRE, transfer valve
160932 GASKET, copper
Pumps
Includes items 101 to 113, 117, and 118
Ref.
104
Part Description
PACKING, o-ring
Qty.
◆
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Air Motor
105
106
107
108
109
110
111
112
113
114
115
116
117
118
191125 CYLINDER, fluid
157182 RETAINER, ball
183009 BODY, intake valve
Ref.
1
Part Description
VALVE, poppet
Qty.
◆
2
1
1
1
1
1
1
1
1
1
2
1
2
2
◆
O-RING, buna-N
2
4
5
5a
6
8
9
160614 PISTON, air motor
101190 BALL, steel, 1” (25 mm) dia
191122 PISTON, fluid
100279 BALL, steel, 0.88” (22.2 mm) dia
116343 SCREW, grounding1
238278 BASE, air motor, includes 5a
116343 SCREW, grounding
◆
O-RING, buna-N
◆
PACKING, u-cup
15H889 ROD, displacement
O-RING, buna-N
110127 SPACER, foot
191128 TUBE, extension, 21.75” (553 mm)
191126 TUBE, extension, 14.25” (362 mm)
191130 TUBE, extension, 26.0” (661 mm)
191131 TUBE, extension, 36.0” (915 mm)
222308 BUNG ADAPTER ASSEMBLY,
includes items 118a and 118b
◆
10
11
12
13
14
15
160624 O-RING, buna-N
203965 ROD, trip
◆
GROMMET, rubber
172867 ACTUATOR, valve
172866 CLIP, spring
102975 SCREW, rd hd mach, no. 6-32 x
1/4” (6.3mm)
118a 104542 SCREW, cap, hex hd, M8 x 1.25”
118b 210834 ADAPTER, bung, bare
1
1
16
17
18
19
◆
POPPET, valve
2
1
1
◆ Parts included in Kit 238286 (purchase separately).
160613 CYLINDER, air motor
‡ Parts included in Kit 222559 (purchase separately).
‡
‡
PLATE, identification, with muffler
SCREW, hex head, no. 8-32 x 0.38 12
inches (10 mm) long
NOTE: Two accessory tools are required for air motor
and throat services: Padded Pliers, 207579, and Gauge,
17181.
20
21
‡
PLATE, warning, with muffler
1
6
101578 SCREW, hex head, 5/16-18 x 0.88”
306518ZAC
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
.
®
5:1 Fire-Ball 300 Pumps
US
Metric
6.2 MPa, 62 bar
5:1
Maximum fluid working pressure
Fluid pressure ratio
900 psi
Air pressure operating range*
Maximum air consumption
40 to 180 psi
0.28 to 1.2 MPa, 2.8 to 12 bar
3
3
13 ft /minute for first gpm
0.096 m /minute for first lpm
pumped at 100 psi up to 8 addi- pumped at 0.7 MPa, 7 bar up to
3
3
tional ft /min for each additional 0.058 additional m /min for each
gpm with pump operated within additional lpm with pump oper-
recommended range
ated within recommended range
Pump cycles per gallon (liters)
7.9
30
Recommended speed for optimum pump life
70 cycles per minute
Maximum recommended pump speed
Wetted Parts
130 cycles per minute 5 gpm
130 cycles per minute 19 lpm
Steel, aluminum, buna-N, urethane
Sound pressure level (measured at 1 meter
from unit)
77.8 dB(A)
85.6 dB(A)
7.7 kg
Sound power level (tested in accordance with
ISO 9614-2)
Approximate weight
17 lb
®
Loctite is a registered trademark of the Loctite Corporation.
(m3/min)
14
306518ZAC
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
Dimensions
Model 203876, Series N, Overall length 20.7 in (526 mm)
Model 203857, Series N, Overall length 45.6 in (1158 mm)
Model 203872, Series N, Overall length 38.1 in (968 mm)
Model 204254, Series S, Overall length 49.9 in (1267 mm)
Model 222087, Series E, Overall length 59.9 in (1521 mm)
grounding
screw
3/8 in.
npt(f) air
inlet
3/8 in.
1/2 in. npt(f)
npt(f) air
fluid outlet
8.9 in.
inlet
grounding
screw
(226 mm)
Model 203857
1/2 in.
npt(f)
fluid
33.8 in. (859 mm)
Overall Length: 20.7 in. (526 mm)
outlet
Model 203872
26.3 in. (668 mm)
Mounting Hole Layout
Model 204254
38.1 in. (968 mm)
Gasket,
Part No.
161023
Model 222087
48.1 in. (1222 mm)
Two 0.265-in. (6.73
mm) diameter holes
on 5-in. (127 mm) bolt
circle
Four 0.265-in. (6.73
mm) diameter holes on
5-in. (127 mm) bolt
circle
3-in. (76.2 mm)
diameter hole
2-Hole Mounting Pattern
4-Hole Mounting Pattern
306518ZAC
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 306518
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 1994, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revised February 2014
Download from Www.Somanuals.com. All Manuals Search And Download.
|