TECHNICAL MANUAL
GSZ/VSZ 13 SEER
Split System Heat Pumps
•
•
•
•
Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.
RT6212006Rev.5
August 2010
Copyright © 2007-2010 Goodman Manufacturing Company, L.P.
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
GSZ130181A*
GSZ130241A*
GSZ130301A*
GSZ130361A*
GSZ130421A*
GSZ130481A*
GSZ130601A*
VSZ130181A*
VSZ130241A*
VSZ130301A*
VSZ130361A*
VSZ130421A*
VSZ130481A*
VSZ130601A*
GSZ130241B*
GSZ130361B*
VSZ130241B*
VSZ130361B*
GSZ130363A*
GSZ130483A*
GSZ130484A*
GSZ130603A*
GSZ130604A*
* Indicates minor revision & is not used for order entry or inventory management
The United States Environmental Protection Agency (“EPA”) has issued various regulations re-
WARNING
garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
To prevent the risk of property
WARNING
WARNING
thatisnotdesigncertifiedbyGood-
damage, personal injury, or death,
man for use with this unit. Serious
do not store combustible materi-
property damage, personal injury, reduced unit perfor-
mance and/or hazardous conditions may result from the
use of such non-approved devices.
als or use gasoline or other flammable liquids or vapors
in the vicinity of this appliance.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DESIGN
GSZ/VSZ13 models are available in 1 1/2 through 5 ton sizes
and use R-410A refrigerant. They are designed for 208/230
volt single phase applications.
NOTE: This unit cannot be completely enclosed. At least
one side must be unrestricted.
These clearances will help avoid air recirculation. If installing
two or more units at the same location, allow at least 24
inches between units. If only one side is restricted (for ex-
ample, against the outside wall of a house), the unit may be
placed as close as 8" to that one wall.
Select GSZ13 models are available in 208/230 and 460 volt
3-phase applications. These models use R-410A refrigerant.
The condenser air is pulled through the condenser coil by a
direct drive propeller fan. This condenser air is then dis-
charged out of the top of the cabinet.
DO NOT locate the unit:
* Directly under a vent termination for a gas appliance.
* Within 3 feet of a clothes drier vent
* Where the refreezing of defrost water would create
a hazard
These units are designed for free air discharge, so no addi-
tional resistance like duct work shall be attached.
The suction and liquid line connections on present models
are of the sweat type for field piping with refrigerant type cop-
per. Front seating valves are factory installed to accept the
field run copper. The total refrigerant charge for a normal in-
stallation is factory installed in the condensing unit. GSZ units
are charged for the matching evaporator coil and a 15 foot
refrigerant line set.
* Where water may rise into the unit.
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Condi-
tioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has ad-
equate capacity to heat or cool the conditioned space.
NOT
RECOMMENDED
OK!
B
OK!
B
B
B
GSZ/VSZ models use high-efficiency Copeland® scroll
"Ultratech" compressors which are specifically desgined for
R-410A refrigerant. There are a number of design character-
istics which are different from the scroll compared to the tra-
ditional reciprocating compressor.
"Ultratech" Series scroll compressors with Copeland®
ComfortAlert diagnositics will not have a discharge thermo-
stat. Some of the early model scroll compressors required
discharge thermostats.
A
AA
AA
AA
OK!
C
C
OK!
AA
AA
AA
OK!
OK!
AA
A
Due to their design Scroll compressors are inherently more
tolerant of small quantities of liquid refrigerant.
C
C
NOTE: Even though the compressor section of a Scroll com-
pressor is more tolerant of liquid refrigerant, continued
floodback or flooded start conditions may wash oil from the
bearing surfaces causing premature bearing failure.
Minimum Airflow Clearance
Model Type
Residential
A
B
C
AA
20"
24"
"Ultratech" Series scroll compressors use "POE" or
polyolester oil which is NOT compatible with mineral oil based
lubricants like 3GS. "POE" oil must be used if additional oil
is required.
10"
12"
10"
12"
18"
18"
Light Commercial
WARNING
To avoid possible injury, explosion or death, practice
safe handling of refrigerants.
Operating pressures and amp draws may differ from stan-
dard reciprocating and/or scroll compressors. This informa-
tion may be found in the "Cooling Performance Data" sec-
tion.
This unit is for outdoor installation only. Refer to minimum
figure for clearances from the sides of the unit to full walls
and other objects.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DESIGN
Product Dimensions
Model
Dimensions - W x D x H
G/VSZ130181A*
G/VSZ130241A*
G/VSZ130241B*
G/VSZ130301A*
26 x 26 x 32¼
26 x 26 x 32¼
26 x 26 x 32½
26 x 26 x 32¼
G/VSZ130361A*
GSZ130363A*
29 x 29 x 38¼
G/VSZ130361B*
G/VSZ130421A*
29 x 29 x 32½
29 x 29 x 38¼
G/VSZ130481A*
GSZ130483A*
GSZ130484A*
G/VSZ130601A*
GZX130603A*
GSZ130604A*
29 x 29 x 34¼
35½ x 35½ x 34¼
5
Download from Www.Somanuals.com. All Manuals Search And Download.
HEAT PUMP SPECIFICATIONS
G/VSZ130[18-60]1A*
Nominal Capacities
Cooling Capacity, BTUH
18,000
17,000
24,000
23,000
30,000
26,400
36,000
34,000
42,000
40,500
48,000
44,000
60,000
58,000
Heating Capacity, BTUH
Compressor
R.L. Amps
9.0
12.8
58.3
14.1
73.0
16.6
79.0
17.9
19.8
26.4
L.R. Amps
48.0
112.0
109.0
134.0
Low Pressure Switch
Open
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
22 PSIG
50 PSIG
Close
High Pressure Switch
Open
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
610 PSIG
420 PSIG
Close
Condenser Fan Motor
Horsepower
1/6
1.10
1/6
1.10
1/6
1.10
1/4
1.50
1/4
1.50
1/4
1.50
1/4
1.50
F.L. Amps
Liquid Line, Inches O.D.*
Suction Line, Inches O.D.*
Refrigerant Charge
Power Supply
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
3/4"
7/8"
7/8"
7/8"
122.0
208/230-60-1
12.3
122.0
208/230-60-1
17.1
127.0
208/230-60-1
18.7
171.0
208/230-60-1
22.3
174.0
208/230-60-1
23.9
222.0
208/230-60-1
26.3
245.0
208/230-60-1
34.5
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Electrical Conduit Size
Power Supply (Inches)
20
25
30
35
40
45
60
1/2 or 3/4
198
1/2 or 3/4
198
1/2 or 3/4
202
1/2 or 3/4
232
1/2 or 3/4
235
1/2 or 3/4
240
1/2 or 3/4
266
Approximate Shipping Weight
*
Up to 24' in equivalent line length
(1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
NOTES:
•
Always check the S & R plate for electrical data on the unit being installed.
•
•
•
Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).
Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).
Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge
Procedure.
•
Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE
OUTDOORUNIT,NOTTHEINDOORCOIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and
wires in accordance with all national and/or local electrical codes. Use copper wire only.
Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general
and electrical information.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
HEAT PUMP SPECIFICATIONS
G/VSZ130[24,36]B*
Nom inal Capac ities
Cooling Capacity, B TUH
24,000
23,000
36,000
34,000
Heating Capac ity , B TUH
Com pres sor
R.L. A m ps
12.8
58.3
16.7
79.0
L.R. A m ps
Low P ress ure S witch
O pen
22 P S IG
50 P S IG
22 P S IG
50 P S IG
Clos e
High P ress ure S witch
O pen
610 P S IG
420 P S IG
610 P S IG
420 P S IG
Clos e
Condenser Fan M otor
Horsepower
1/6
1.10
1/4
1.50
F.L. A m ps
Liquid Line, Inches O .D.*
S uction Line, Inc hes O .D.*
Refrigerant Charge
P ower S upply
3/8"
3/8"
3/4"
3/4"
113.0
208/230-60-1
17.1
131.0
208/230-60-1
22.3
M inim um Circ uit A m pacity(1)
M axim um O verc urrent Device(2)
E lectric al Conduit S iz e
25
35
P ower S upply (Inc hes)
1/2 or 3/4
162
1/2 or 3/4
182
A pprox im ate S hipping W eight
(1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2) Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
(3)
Tested and rated in accordance with AHRI Standard 210/240
NOTES:
•
Always check the S & R plate for electrical data on the unit being installed.
•
•
•
Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).
Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).
Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge
Procedure.
•
Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE
OUTDOORUNIT,NOTTHEINDOORCOIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and
wires in accordance with all national and/or local electrical codes. Use copper wire only.
Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general
and electrical information.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
HEAT PUMP SPECIFICATIONS
GSZ130[36-60][3,4]A*
Nominal Capacities
Cooling Capacity, BTUH
36,000
48,000
48,000
60,000
60,000
Heating Capacity, BTUH
Decibels
34,000
74
44,000
76
44,000
76
58,000
75
58,000
75
Compressor
R.L. Amps
10.4
73.0
13.1
83.1
6.1
16.0
110.0
Scroll
7.8
L.R. Amps
41.0
52.0
Type
Scroll
Scroll
Scroll
Scroll
Condenser Fan Motor
Horsepower
1/4
1/4
1/4
1/4
1/4
F.L. Amps
1.50
1.50
0.80
1.50
0.80
Refrigerant System
Liquid Line, Inches O.D.*
3
3/8"
7/8"
3/8"
1 1/8"
3/8"
3/8"
1 1/8"
3/8"
3/8"
1 1/8"
3/8"
3/8"
1 1/8"
3/8"
3
Suction Line, Inches O.D.*
Liquid Valve Connection, Inches O.D.*
Suction Valve Connection, Inches O.D.*
Refrigerant Charge
3/8"
3/4"
7/8"
7/8"
7/8"
7/8"
171.0
0.068
208/230-60-3
14.5
222.0
222.0
0.078
460-60-3
8.4
245.0
245.0
0.088
460-60-3
10.6
Piston Size
0.078
0.088
Power Supply
208/230-60-3
17.9
208/230-60-3
21.5
Minimum Circuit Ampacity(1)
Maximum Overcurrent Device(2)
Min / Max Volts
20
30
15
35
15
197 / 253
197 / 253
414 / 506
197 / 253
414 / 506
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/4
232
1/2 or 3/4
235
1/2 or 3/4
234
1/2 or 3/4
262
1/2 or 3/4
261
Approximate Shipping Weight
(1) Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
Tested and rated in accordance with AHRI Standard 210/240
(3)
NOTES:
•
Always check the S & R plate for electrical data on the unit being installed.
•
•
•
Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).
Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).
Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge
Procedure.
•
Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE
OUTDOORUNIT,NOTTHEINDOORCOIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and
wires in accordance with all national and/or local electrical codes. Use copper wire only.
Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general
and electrical information.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130181A*
9
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130181A*
10
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130241A*
11
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130241A*
12
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130241B*
13
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130241B*
14
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130301A*
15
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130301A*
16
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130361A*
17
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130361A*
18
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130361B*
19
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130361B*
20
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GZ130363A*
21
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GZ130363A*
22
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130421A*
23
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130421A*
24
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130481A*
25
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130481A*
26
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130483A*
27
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130483A*
28
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130484A*
29
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130484A*
30
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130601A*
31
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
G/VSZ130601A*
32
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130603A*
33
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130603A*
34
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130604A*
35
Download from Www.Somanuals.com. All Manuals Search And Download.
COOLING PERFORMANCE DATA
GSZ130604A*
36
Download from Www.Somanuals.com. All Manuals Search And Download.
SPLIT SYSTEM HEATING PERFORMANCE
EXPANDED PERFORMANCE DATA
MODEL: G/VSZ130181A* / AR*F182416**
HEATING OPERATION
Outdoor Am bient Tem perature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
21.4
20.2
31.2
1.64
6.7
19.0
29.4
1.61
6.3
17.8
27.5
1.58
5.9
17.0
26.2
1.56
5.7
16.5
25.4
1.54
5.6
15.3
23.6
1.51
5.3
14.1
21.8
1.48
5.0
13.3
20.6
1.46
4.8
12.3
19.0
1.42
4.6
11.3
17.5
1.39
4.3
10.7
16.5
1.37
4.2
10.3
15.9
1.36
4.2
9.2
14.3
1.32
4.0
8.2
12.7
1.29
3.7
7.2
11.0
1.26
3.5
6.1
9.4
5.0
7.7
DELTA T 33.0
KW
AMPS
COP
1.68
7.3
1.23
3.2
1.19
2.9
3.73
12.8
392
145
3.60
12.3
375
134
3.46
11.8
361
126
3.30
11.3
345
115
3.19
10.9
337
109
3.12
10.7
331
105
2.96
10.1
318
96
2.79
9.5
2.68
9.2
2.53
8.7
2.39
8.2
2.29
7.8
2.22
7.6
2.04
7.0
1.86
6.3
1.66
5.7
1.46
5.0
1.22
4.2
EER
HI PR
LO PR
305
86
292
77
279
69
268
61
262
57
257
55
247
46
238
40
228
34
220
29
212
23
MODEL: G/VSZ130241A* / AR*F182416**
HEATING OPERATION
Outdoor Am bient Tem perature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
DT
28.9
32.6
2.20
9.7
27.4
30.9
2.15
9.0
25.8
29.1
2.11
8.4
24.1
27.2
2.07
7.9
23.0
26.0
2.04
7.6
22.3
25.2
2.02
7.5
20.7
23.4
1.98
7.0
19.1
21.6
1.94
6.7
16.7
18.9
1.75
6.4
15.4
17.4
1.71
6.1
14.2
16.0
1.67
5.8
13.4
15.1
1.65
5.6
12.9
14.6
1.63
5.6
11.6
13.1
1.59
5.3
10.3
11.6
1.56
4.9
9.0
10.1
1.52
4.6
7.6
8.6
6.3
7.1
KW
1.48
4.3
1.44
3.8
AMPS
COP
EER
3.85
13.2
407
135
3.72
12.7
390
126
3.57
12.2
375
118
3.41
11.7
358
108
3.30
11.3
350
102
3.23
11.0
343
98
3.06
10.5
330
90
2.89
9.9
2.79
9.5
2.63
9.0
2.48
8.5
2.38
8.1
2.31
7.9
2.13
7.3
1.93
6.6
1.73
5.9
1.51
5.2
1.27
4.4
HI PR
LO PR
317
80
303
73
290
65
278
57
272
53
267
51
257
43
247
37
237
31
228
27
220
22
MODEL: G/VSZ130241B*/ AR*F182416**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
Delta T
KW
28.9
33.5
2.17
10.1
3.91
13.3
413
27.4
31.7
2.12
9.3
25.8
29.8
2.08
8.7
24.1
27.9
2.04
8.2
22.3
25.8
2.00
7.7
20.7
24.0
1.96
7.3
19.1
22.1
1.91
6.9
16.9
19.5
1.80
6.6
15.6
18.0
1.76
6.3
14.3
16.6
1.72
6.0
13.6
15.7
1.70
5.9
13.0
15.1
1.68
5.8
11.7
13.6
1.64
5.5
10.4
12.0
1.60
5.2
9.1
10.5
1.57
4.9
7.7
8.9
6.3
7.3
23.0
26.6
2.02
7.9
1.52
4.5
1.49
4.0
AMPS
COP
3.77
12.9
395
122
3.62
12.4
380
114
3.46
11.8
364
105
3.34
11.4
355
99
3.27
11.2
348
95
3.10
10.6
335
88
2.92
10.0
321
78
2.74
9.4
2.59
8.8
2.44
8.3
2.33
8.0
2.27
7.7
2.08
7.1
1.89
6.5
1.69
5.8
1.48
5.1
1.25
4.3
EER
HI PR
LO PR
308
70
294
63
282
55
275
51
271
50
260
42
250
36
240
30
231
27
223
21
131
MODEL: G/VSZ130301A* / AR*F30301**
HEATING OPERATION
Outdoor Am bie nt Te m pe rature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
DELTA T
KW
33.2
29.3
2.52
9.7
31.4
27.7
2.47
9.0
29.6
26.1
2.42
8.5
27.6
24.4
2.37
8.0
26.4
23.3
2.35
7.7
25.6
22.6
2.32
7.6
23.8
21.0
2.28
7.2
21.9
19.3
2.23
6.9
19.9
17.6
2.37
6.6
18.4
16.2
2.32
6.3
16.9
14.9
2.26
6.0
16.0
14.1
2.23
5.9
15.4
13.6
2.21
5.8
13.8
12.2
2.16
5.6
12.3
10.8
2.11
5.2
10.7
9.4
9.1
8.0
7.5
6.6
2.05
5.0
2.00
4.6
1.95
4.2
A MPS
COP
3.86
13.2
366
129
3.72
12.7
351
119
3.57
12.2
337
112
3.41
11.6
323
103
3.29
11.3
315
97
3.22
11.0
309
93
3.05
10.4
297
86
2.88
9.8
2.46
8.4
2.32
7.9
2.19
7.5
2.10
7.2
2.04
7.0
1.88
6.4
1.70
5.8
1.52
5.2
1.34
4.6
1.12
3.8
EER
HI PR
LO PR
285
76
273
69
261
62
250
54
244
50
240
49
231
41
222
35
213
30
205
26
198
20
High pressure is measured at the liquid service valve (the smaller valve).
Low pressure is measured at the gauge port connection.
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note:ShadedareaisAHRIRatingConditionsat 47°outdoorambienttemberature
37
Download from Www.Somanuals.com. All Manuals Search And Download.
SPLIT SYSTEM HEATING PERFORMANCE
EXPANDED PERFORMANCE DATA
MODEL: G/VSZ130361A* / AR*F364216**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
42.7
40.5
29.4
3.01
13.2
3.93
13.4
356
123
38.1
27.7
2.96
12.3
3.77
12.9
343
115
35.6
25.9
2.90
11.6
3.59
12.3
328
106
32.9
23.9
2.85
11.0
3.39
11.6
314
30.6
22.2
2.79
10.4
3.21
11.0
302
28.2
20.5
2.74
9.9
19.9
14.5
2.82
9.4
18.4
13.4
2.76
9.0
16.9
12.3
2.70
8.6
16.0
11.6
2.67
8.4
15.4
11.2
2.64
8.3
13.8
10.0
2.58
7.9
12.3
8.9
10.7
7.8
9.1
6.6
7.5
5.4
34.0
24.7
2.87
11.2
3.47
11.8
320
100
DELTA T 31.0
KW
AMPS
COP
3.07
14.2
4.07
13.9
372
133
2.52
7.4
2.46
7.0
2.40
6.5
2.35
5.8
3.02
10.3
290
2.07
7.1
1.95
6.7
1.84
6.3
1.76
6.0
1.71
5.8
1.57
5.4
1.42
4.9
1.27
4.3
1.11
3.8
0.93
3.2
EER
HI PR
LO PR
277
71
265
64
254
56
248
52
244
50
235
42
226
37
216
31
209
27
201
21
96
89
79
MODEL: G/VSZ130361B* / AR*F364216**
HEATINGOPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
Delta T
KW
42.7
33.0
3.09
14.0
4.05
13.8
383
40.5
31.2
3.03
13.0
3.91
13.4
368
38.1
29.4
2.97
12.1
3.76
12.8
353
35.6
27.5
2.90
11.4
3.59
12.3
338
32.9
25.4
2.84
10.8
3.39
11.6
324
96
30.6
23.6
2.79
10.2
3.21
11.0
311
89
28.2
21.8
2.73
9.7
2.6
2.0
2.4
1.9
2.2
1.7
2.1
1.6
2.0
1.6
1.8
1.4
1.6
1.2
1.4
1.1
1.2
0.9
1.0
0.8
34.0
26.2
2.87
11.0
3.47
11.8
330
2.70
9.3
2.64
8.8
2.58
8.4
2.54
8.2
2.52
8.1
2.45
7.7
2.39
7.2
2.33
6.8
2.27
6.3
2.21
5.6
AMPS
COP
3.03
10.4
299
79
0.28
1.0
0.27
0.9
0.25
0.9
0.24
0.8
0.23
0.8
0.22
0.7
0.20
0.7
0.18
0.6
0.15
0.5
0.13
0.4
EER
HI PR
LO PR
286
71
273
64
262
56
256
52
251
50
242
42
233
37
223
31
215
27
208
21
133
123
115
106
100
MODEL: GSZ130363A* / AR*F364216**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
30.6
22.2
2.63
7.4
35
28.2
20.5
2.58
7.0
30
19.9
14.5
2.42
6.7
25
18.4
13.4
2.37
6.5
20
16.9
12.3
2.32
6.2
17
16.0
11.6
2.29
6.0
15
15.4
11.2
2.27
6.0
10
13.8
10.0
2.22
5.7
5
0
-5
9.1
6.6
2.07
4.7
1.29
4.4
215
28
-10
7.5
MBh
DT
42.7
31.0
2.90
9.9
40.5
29.4
2.84
9.2
38.1
27.7
2.79
8.7
35.6
25.9
2.73
8.2
34.0
24.7
2.70
7.9
32.9
23.9
2.68
7.8
12.3
8.9
10.7
7.8
5.4
KW
2.17
5.3
2.12
5.1
2.02
4.3
AMPS
COP
EER
4.32
14.8
383
138
4.17
14.2
368
128
4.00
13.7
353
120
3.81
13.0
338
110
3.68
12.6
330
104
3.60
12.3
324
100
3.41
11.6
311
92
3.21
11.0
299
82
2.41
8.2
2.27
7.8
2.14
7.3
2.05
7.0
1.99
6.8
1.82
6.2
1.65
5.7
1.48
5.0
1.08
3.7
HI PR
LO PR
286
74
273
66
262
58
256
54
251
52
242
44
233
38
223
32
208
22
High pressure is measured at the liquid service valve (the smaller valve).
Low pressure is measured at the gauge port connection.
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note:ShadedareaisAHRIRatingConditionsat 47°outdoorambienttemberature
38
Download from Www.Somanuals.com. All Manuals Search And Download.
SPLIT SYSTEM HEATING PERFORMANCE
EXPANDED PERFORMANCE DATA
MODEL: G/VSZ130421A* / AR*F36421**
Outdoor Am bient Tem perature
HEATING OPERATION
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
DT
50.3
34.5
3.60
16.9
4.09
14.0
368
47.6
32.6
3.53
15.6
3.95
13.5
353
44.8
30.7
3.46
14.5
3.79
12.9
340
41.9
28.7
3.39
13.6
3.62
12.4
325
40.0
27.4
3.35
13.1
3.49
11.9
317
97
38.8
26.6
3.32
12.9
3.42
11.7
311
93
36.0
24.7
3.25
12.1
3.24
11.1
299
86
33.2
22.8
3.18
11.5
3.05
10.4
287
76
29.9
20.5
3.24
10.9
2.70
9.2
27.6
18.9
3.16
10.4
2.55
8.7
25.4
17.4
3.09
9.9
24.0
16.5
3.05
9.7
23.1
15.9
3.02
9.5
20.7
14.2
2.95
9.0
18.4
12.6
2.88
8.4
16.0
11.0
2.80
7.9
13.7
9.4
11.2
7.7
KW
2.73
7.2
2.66
6.4
AMPS
COP
EER
2.40
8.2
2.30
7.9
2.24
7.6
2.06
7.0
1.87
6.4
1.67
5.7
1.47
5.0
1.23
4.2
HI PR
LO PR
275
69
262
62
252
54
246
50
242
49
232
41
223
35
214
30
207
26
199
20
129
119
112
103
MODEL: G/VSZ130481A* /AR*F48601**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
DELTA T
KW
55.3
32.0
3.93
18.2
4.11
14.1
380
129
52.4
30.3
3.87
16.8
3.96
13.5
364
119
49.3
28.5
3.80
15.7
3.80
13.0
350
112
46.1
26.7
3.73
14.8
3.62
12.4
335
103
44.0
25.5
3.69
14.3
3.49
11.9
327
97
42.6
24.7
3.66
14.0
3.41
11.7
321
39.6
22.9
3.59
13.2
3.23
11.0
308
36.5
21.1
3.52
12.5
3.03
10.4
296
33.6
19.5
3.37
12.0
2.93
10.0
284
31.1
18.0
3.30
11.4
2.76
9.4
28.6
27.0
15.6
3.19
10.6
2.47
8.5
26.0
15.0
3.17
10.5
2.40
8.2
23.3
13.5
3.10
9.9
20.7
12.0
3.04
9.3
18.0
10.4
2.97
8.7
15.4
8.9
12.6
7.3
16.5
3.23
10.9
2.59
8.8
2.90
8.1
2.84
7.3
AMPS
COP
2.20
7.5
1.99
6.8
1.78
6.1
1.55
5.3
1.30
4.4
EER
HI PR
LO PR
271
260
54
254
50
249
49
240
41
231
35
221
30
213
26
206
20
93
86
76
69
62
MODEL: G/VSZ130601A* / AR*F48601**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
35
30
25
20
17
15
10
5
0
-5
-10
MBh
72.9
69.0
35.5
5.11
22.2
3.95
13.5
399
123
65.0
33.4
5.01
20.7
3.79
13.0
383
115
60.7
31.2
4.92
19.5
3.62
12.4
367
106
56.2
28.9
4.82
18.4
3.41
11.7
351
52.2
26.9
4.72
17.3
3.23
11.1
338
48.1
24.8
4.63
16.4
3.05
10.4
324
44.9
23.1
4.66
15.7
2.82
9.6
41.4
21.3
4.56
15.0
2.66
9.1
38.1
19.6
4.46
14.2
2.50
8.6
36.0
18.5
4.40
13.9
2.40
8.2
34.7
17.8
4.36
13.7
2.33
8.0
31.1
16.0
4.26
13.0
2.14
7.3
27.6
14.2
4.16
12.1
1.94
6.6
24.0
12.4
4.06
11.3
1.73
5.9
20.5
10.6
3.96
10.5
1.52
5.2
16.8
8.6
58.0
29.8
4.86
18.8
3.49
11.9
358
100
DELTA T 37.5
KW
AMPS
COP
5.21
24.0
4.10
14.0
416
133
3.86
9.4
1.28
4.4
EER
HI PR
LO PR
310
296
285
278
52
273
50
262
42
252
37
242
31
233
27
225
21
96
89
79
71
64
56
High pressure is measured at the liquid service valve (the smaller valve).
Low pressure is measured at the gauge port connection.
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note:ShadedareaisAHRIRatingConditionsat 47°outdoorambienttemberature
39
Download from Www.Somanuals.com. All Manuals Search And Download.
SPLIT SYSTEM HEATING PERFORMANCE
EXPANDED PERFORMANCE DATA
MODEL: GSZ130483A* / AR*F486016**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
44.0
25.5
3.68
8.8
45
42.6
24.7
3.65
8.6
40
39.6
22.9
3.58
8.2
35
36.5
21.1
3.51
7.8
30
33.6
19.5
3.49
7.5
25
31.1
18.0
3.42
7.2
20
28.6
16.5
3.34
6.8
17
27.0
15.6
3.30
6.7
15
26.0
15.0
3.27
6.6
10
23.3
13.5
3.20
6.3
5
0
-5
15.4
8.9
-10
12.6
7.3
MBh
DT
55.3
32.0
3.94
11.1
4.10
14.0
386
52.4
30.3
3.87
10.3
3.96
13.5
370
49.3
28.5
3.80
9.7
46.1
26.7
3.72
9.1
20.7
12.0
3.12
5.9
18.0
10.4
3.05
5.6
KW
2.98
5.2
2.90
4.7
AMPS
COP
EER
3.80
13.0
356
110
3.62
12.4
340
101
3.50
11.9
332
95
3.42
11.7
326
91
3.24
11.1
313
84
3.05
10.4
300
75
2.82
9.6
2.66
9.1
2.50
8.6
2.39
8.2
2.33
7.9
2.14
7.3
1.94
6.6
1.73
5.9
1.51
5.2
1.27
4.3
HI PR
LO PR
288
68
275
60
264
53
258
49
253
48
243
40
234
35
224
29
216
26
209
20
126
117
MODEL: GSZ130484A* / AR*F486016**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
44.0
25.5
3.68
4.9
45
42.6
24.7
3.65
4.8
40
39.6
22.9
3.58
4.6
35
36.5
21.1
3.51
4.4
30
33.6
19.5
3.49
4.2
25
31.1
18.0
3.42
4.0
20
28.6
16.5
3.34
3.8
17
27.0
15.6
3.30
3.8
15
26.0
15.0
3.27
3.7
10
23.3
13.5
3.20
3.5
5
0
-5
15.4
8.9
-10
12.6
7.3
MBh
DT
55.3
32.0
3.94
6.1
52.4
30.3
3.87
5.7
49.3
28.5
3.80
5.4
46.1
26.7
3.73
5.1
20.7
12.0
3.12
3.3
18.0
10.4
3.05
3.2
KW
2.98
3.0
2.90
2.7
AMPS
COP
EER
4.10
14.0
386
126
3.96
13.5
370
117
3.80
13.0
356
110
3.62
12.4
340
101
3.50
11.9
332
95
3.42
11.7
326
91
3.24
11.1
313
84
3.05
10.4
300
75
2.82
9.6
2.66
9.1
2.50
8.6
2.39
8.2
2.33
7.9
2.14
7.3
1.94
6.6
1.73
5.9
1.51
5.2
1.27
4.3
HI PR
LO PR
288
68
275
60
264
53
258
49
253
48
243
40
234
35
224
29
216
26
209
20
MODEL: GSZ130603A* /AR*F486016**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
40
52.2
26.9
4.72
9.5
35
48.1
24.8
4.62
9.0
30
44.9
23.1
4.65
8.6
25
41.4
21.3
4.55
8.2
20
38.1
19.6
4.45
7.8
17
36.0
18.5
4.39
7.7
15
34.7
17.8
4.34
7.6
10
31.1
16.0
4.24
7.2
5
0
-5
-10
16.8
8.6
MBh
DT
72.9
37.5
5.21
13.1
4.10
14.0
416
69.0
35.5
5.11
12.2
3.95
13.5
399
65.0
33.4
5.01
11.4
3.79
13.0
383
115
60.7
31.2
4.91
10.7
3.62
12.4
367
58.0
29.8
4.86
10.3
3.50
11.9
358
56.2
28.9
4.81
10.1
3.42
11.7
351
96
27.6
14.2
4.14
6.7
24.0
12.4
4.04
6.3
20.5
10.6
3.94
5.8
KW
3.84
5.2
AMPS
COP
EER
3.24
11.1
338
89
3.05
10.4
324
79
2.82
9.6
2.67
9.1
2.51
8.6
2.40
8.2
2.34
8.0
2.15
7.3
1.95
6.7
1.74
6.0
1.53
5.2
1.28
4.4
HI PR
LO PR
310
71
296
64
285
56
278
52
273
50
262
42
252
37
242
31
233
27
225
21
133
123
106
100
MODEL: GSZ130604A* /AR*F486016**
HEATING OPERATION
Outdoor Ambient Temperature
65
60
55
50
47
45
56.2
28.9
4.81
5.1
40
52.2
26.9
4.72
4.8
35
48.1
24.8
4.62
4.6
30
44.9
23.1
4.65
4.4
25
41.4
21.3
4.55
4.2
20
38.1
19.6
4.45
4.1
17
36.0
18.5
4.39
4.0
15
34.7
17.8
4.34
3.9
10
31.1
16.0
4.24
3.7
5
0
-5
-10
16.8
8.6
MBh
DT
72.9
37.5
5.21
6.5
69.0
35.5
5.11
6.1
65.0
33.4
5.01
5.7
60.7
31.2
4.91
5.4
58.0
29.8
4.86
5.2
27.6
14.2
4.14
3.5
24.0
12.4
4.04
3.3
20.5
10.6
3.94
3.1
KW
3.84
2.8
AMPS
COP
EER
4.10
14.0
416
133
3.95
13.5
399
123
3.79
13.0
383
115
3.62
12.4
367
106
3.50
11.9
358
100
3.42
11.7
351
96
3.24
11.1
338
89
3.05
10.4
324
79
2.82
9.6
2.67
9.1
2.51
8.6
2.40
8.2
2.34
8.0
2.15
7.3
1.95
6.7
1.74
6.0
1.53
5.2
1.28
4.4
HI PR
LO PR
310
71
296
64
285
56
278
52
273
50
262
42
252
37
242
31
233
27
225
21
High pressure is measured at the liquid service valve (the smaller valve).
Low pressure is measured at the gauge port connection.
AMPS = Outdoor unit amps (comp.+fan)
KW = Total system power
Calculations are based on nominal CFM and 70 °F indoor dry bulb.
*Note:ShadedareaisAHRIRatingConditionsat 47°outdoorambienttemberature
40
Download from Www.Somanuals.com. All Manuals Search And Download.
PERFORMANCE DATA
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the Heat Pump
Specifications.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
NOTE: Pressures are measured at the liquid and suction service valve ports.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAMS
G/VSZ130[18-60]1[A/B]*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Y L N R O O T C A N T C O L E O P
E L B U O D E T A N R E L T
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAMS
GSZ130[36-60][3,4]A*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Dyson Vacuum Cleaner DC02 User Manual
Esoteric DVD Player D 03 User Manual
Extron electronic Network Card DVI 201 A D User Manual
FoodSaver Food Saver V2240 CN User Manual
Fostex Recording Equipment X 30 User Manual
GE Fax Machine D780 User Manual
GE Label Maker RPN1605 User Manual
Gemini Musical Instrument PS 650I User Manual
Generac Portable Generator 005982 0 User Manual
Global Machinery Company Brush Cutter 25CC User Manual