TECHNICAL MANUAL
AVPTC Air Handlers
•
•
•
•
Refer to Service Manual RS6200006 for installation, operation & troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury due to improper
service procedures or services performed by an unqualified person.
RT6121001r2
January2011
Copyright © 2010 - 2011 Goodman Manufacturing Company, L.P.
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
AVPTC183014**
AVPTC313714**
AVPTC426014**
The United States Environmental Protection Agency (“EPA”) has issued various regulations re-
garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow
WARNING
these regulations may harm the environment and can lead to the imposition of substantial fines.
These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device
To prevent the risk of property
WARNING
WARNING
that is not design certified by
Goodman for use with this unit.
damage, personal injury, or death,
do not store combustible materials or use gasoline or
other flammable liquids or vapors in the vicinity of this
appliance.
Serious property damage, personal injury, reduced unit
performance and/or hazardous conditions may result
from the use of such non-approved devices.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DESIGN
WARNING
When installing or servicing this equipment, safety
clothing, including hand and eye protection, is
strongly advised. If installing this equipment in an
area that has special safety requirements (hard hats
etc.), observe these requirements. To protect the
unit when brazing close to the painted surfaces,
the use of a quenching cloth is strongly advised to
prevent scorching or marring of the equipment fin-
ish.
AIR HANDLERS
*See Air Handler Specification Sheet for Proper Combinations.
ALL AIR HANDLERS USE DIRECT DRIVE MO-
TORS. POWER SUPPLY IS 220-240 V, 60 HZ, 1
PHASE
Installation
Before installing this appliance insure that it is properly sized
and adequate power is available.
This appliance can be installed in the vertical position with-
out modification.
The horizontal left and downflow positions require product
modification and instructions for these field conversions can
be found in the AVPTC installation instruction manual.
This product is designed for zero inches (0 inches) clear-
ance; however, adequate access for service or replacement
must be considered without removing permanent structure.
This unit can be installed on a platform when deemed neces-
sary.
In an attic installation a secondary drain pan must be pro-
vided by the installer and placed under the entire unit with a
separate drain line properly sloped and terminated in an area
visible to the owner. This secondary drain pan is required in
the event that there is a leak or main drain blockage. Closed
cell insulation should be applied to the drain lines in uncondi-
tioned spaces where sweating may occur.
WARNING
The unit MUST have an uninterrupted, unbroken
electrical ground to minimize the possibility of per-
sonal injury if an electrical fault should occur. The
electrical ground circuit may consist of an appro-
priately sized electrical wire connecting the
ground lug in the unit control box to the building
electrical service panel. Other methods of ground-
ing are permitted if performed in accordance with
the “National Electric Code” (NEC)/“American Na-
tional Standards Institute” (ANSI)/“National Fire
Protection Association” (NFPA) 70 and local/state
codes. In Canada, electrical grounding is to be in
accordance with the Canadian Electric Code CSA
C22.1. Failure to observe this warning can result
in electrical shock that can cause personal injury
or death.
Appliances installed in garages, warehouses or other areas
where they may be subjected to mechanical damage must
be suitably guarded against such damage by installing be-
hind protective barriers, being elevated or located out of the
normal path of vehicles. When installed on a base, the base
must also be protected by similar means.
Heating and cooling equipment located in garages, which
may generate a glow, spark or flame capable of igniting flam-
mable vapors, must be installed with the ignition source at
least 18"[46cm] above the floor level.
When more than one appliance is installed in a building it
shall be permanently identified as to the area or space ser-
viced by the equipment.
WARNING
If this appliance is installed in an enclosed area
such as a garage or utility room with any carbon
monoxide (CO) producing appliance (i.e. automo-
bile, furnace, water-heaters, etc.), ensure the area
is properly ventilated.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DESIGN
When this product is installed in the downflow installation in
an unconditioned space, remove the horizontal drain pan and
install the following insulation kit
See following chart for the correct DPIH kit.
AVPTC Model
Insulation Kit
AVPTC Model
Insulation Kit
1830
DPIH36-42
1830
DPI36-42/20
3137
4260
DPIH48-61
3137
4260
DPI48-61/-20
*AVPTC is a multi-position, variable-speed air handler and is
used with R-410A. The unit's blower design includes a vari-
able-speed ECM motor and is compatible with heat pumps
and variable-capacity cooling applications. (See note below.)
This kit is used to prevent sweating on the vertical drain pan.
To prevent the horizontal drain pan from sweating in high
humidity applications, it is recommended that a DPIH
insulation accessory kit be used. NOTE: The DPIH insu-
lation kit is not supplied with this product and must be
purchasedseparately.
*NOTE: Factory-sealedtoachievea2%orlessleakagerate
at 1.0" water gauge external duct static pressure.
Complies with the Factory-sealed Air Handling Credit as
listedinthe2001FloridaBuildingCode,Chapter13,Section
610.2.A.2.1.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
AVPTC
PRODUCT DIMENSIONS
D
C
B
E
A
SUCTION
LINE
LIQUID
LINE
INLET
TUBE
F
G
I
INLET
(RIGHT SIDE VIEW)
H
INLET
(FRONT VIEW)
Model
A
B
C
D
E
F
G
H
I
J
AVPTC183014
46 3/4"
53 1/4"
53 1/4"
22"
24"
24"
17 1/2"
20"
19 1/2"
22"
10'
12"
12"
14 1/2" 11 15/16" 17 1/8" 17 15/16"
2"
19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16"
19 5/8" 11 15/16" 19 5/8" 19 15/16" 1 13/16"
AVPTC313714
AVPTC426014
20"
22"
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
AVPTC
AVPTC183016* AVPTC313716* AVPTC426016*
Blower Wheel
Diameter
9 1/2"
8"
10 5/8"
10 5/8"
10 5/8"
10 5/8"
Width
Lineset Connection Size
Coil Drain Connection FPT
Liquid
3/4"
3/8"
3/4"
3/4"
3/8"
7/8"
3/4"
3/8"
7/8"
Suction
Electrical Data
Voltage
208/240
4.9/4.9
15/15
197
208/240
6.5/6.5
15/15
197
208/240
8.6/8.6
15/15
197
Min. Circuit Ampacity
Max. Overcurrent Device (amps)
Minimum VAC
Maximum VAC
Blower Motor
FLA
253
253
253
3.90
1/2
5.20
3/4
6.90
1
HP
Ship Weight (lbs)
127
178
197
7
Download from Www.Somanuals.com. All Manuals Search And Download.
BLOWER PERFORMANCE DATA
Electric Heat Airflow and Temperature Rise Table
Speed Selection Dip Switches
Cool
Adjust
Selection Selection
Switches Switches
Profile
Htr Kw
9
10 11 AVPTC 183014* AVPTC 313714* AVPTC 426014*
Selection
Switches
3
5
ON
ON
ON
ON
ON
600
700
600
700
600
700
OFF
TAP
1
2
3
4
5
6
A
B
OFF OFF OFF OFF OFF OFF
ON OFF ON OFF ON OFF
OFF ON OFF ON OFF ON
ON ON ON ON ON ON
6
8
ON OFF
ON
800
800
800
ON OFF OFF
OFF ON ON
OFF ON OFF
1000
1000
1000
C
10
15
1200
NR
1200
1400
NR
1200
1400
D
20
21
OFF OFF ON
OFF OFF OFF
NR
NR
1600
1600
Profiles
A
Pre-Run
-------
Short-Run
--------
OFF Delay
60 sec/100%
60 sec/100%
60 sec/100%
30 sec/50%
NR
B
-------
30 sec/50%
7.5 min/82%
7.5 min/82%
NOTE: Airflow data shown applies to the emergency heat mode (electric heat only)
in either legacy mode operation or fully communicating mode operation.
C
-------
Cooling/Heat Pump Airflow Table
D
30 sec/50%
To set airflow:
(1) Select model and desired
Model
Tap
Low Stage
Cool
High Stage
Cool
high stage cooling airflow. Determine the cooresponding tap
( A, B, C, or D ). Set dip switches 1 and 2 to the appropriate
ON / OFF positions. (2) Select model and installed electric
heater size. Set switches 9, 10, and 11 to the appropriate
ON/OFF positions. (3) Select the airflow adjustment factor tap
A and D are 0%; Tap B is +10%; Tap C -10%. Set dip switches 3
and 4 to the appropriate ON / OFF positions.
A
B
C
D
422
563
694
825
630
840
1036
1232
AVPTC 183014
*
A
B
C
D
409
553
696
829
610
825
1040
1237
To set Comfort Mode:
(see profiles above). Set switches 5 and 6 to the approriate
ON / OFF positions.
Select desired Comfort Mode profile
AVPTC 313714
*
A
810
1210
AVPTC 426014
*
C
D
1047
1209
1562
1804
0140A00048 REV A
Heat Kit Selection
MODELS
HKR-03*
AVPTC183014A*
AVPTC313714*
AVPTC426014A*
X
X
X
X
X
X
HKR-05*/-05C*
HKR-06*
X
X
X
HKR-08*/-08C*
HKR-10*/-10C*
HKR-15C
X
X
X
X1
X
X
X2
X
X3
X3
HKR-20C
HKR-21C
*
Revision level that may or may not be designated.
Circuit breaker option.
C
1
For units operating in Legacy mode, use dip switches 9-ON, 10-OFF, 11-OFF, to obtain 1000 CFM, or 9-OFF, 10-ON, 11-ON to obtain 1200 CFM.
For units operating in Communicating mode, use dip switch 8 kW Htr to obtain 1000 CFM or 10 kW Htr to obtain 1200 CFM.
This heater kit can only be used for ‘1000 CFM or higher’ applications.
2
3
This heater kit can only be used for ‘1200 CFM or higher’ applications.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
BLOWER PERFORMANCE DATA
Outdoor
Control
TERM
Data Line
Voltages, Vdc
Indoor Control
TERM
Dipswitch
BIAS Dipswitches
Dipswitches
1-C
2-C
1-2
Switch 1 Switch 2 Switch 3
Switch 1 Switch 2
ON
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
>2.5
>2.8
>2.8
>2.8
5
<2.5
<2.2
<2.2
<2.2
0
>0.2
>0.6
>0.6
>0.6
5
OFF
ON
OFF
ON
0
0
0
ON
5
5
0
ON or
OFF
ON or
OFF
OFF
OFF
ON or OFF
0
0
0
TERM1 / TERM2 = Termination dipswitches at outdoor unit. See installation
instructions with CTTM compatiable outdoor unit.
OFF ON
1
BIAS
BIAS
2
3
TERM
Indoor Unit BIAS and TERMINATION Dipswitches
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAMS
AVPTC
FL
FL
FL
FL
FL
FL
FL
FL
TL
TL
TL
TL
HTR1
BK
RD
TL
TL
HTR 2
HTR1
HTR1 TL
HTR1 TL
BK
FL
FL
HTR2
TL
TL
HTR2
HTR3
RD
RD
HTR3
HTR4
YL
BK
BK
1
2
BK
BK
1
2
3
4
BL
BK
1
2
3
BK
1
2
3
RD
PU
BL
YL
3
4
RD
RD
BK
PU
YL
BK
PU
PU
BL
BL
RD
BK
BL
BK
RD
RD
BL
BL
M1
M2
M1
M2
M3
M1
M2
RD
BL
R
4
5
M1
M2
M3
M4
M5
M6
M7
M8
M1
M3
M4
RD
M4
YL
5
6
7
8
9
4
5
RD
R1
R2
R
BR
5
6
7
8
9
R1
R2
M2
BK
BR
WH
BK
BK
RD
RD
WH
6
7
8
9
BK
WH
WH
6
7
8
9
BK
BK
RD
BK
RD
YL
BK
YL
RD
BK
RD
BL
BK
RD
L1 L2
L1 L2
L1 L2 L1 L2
FOUR (4) ELEMENT ROWS
ONE (1) ELEMENT ROWS
TWO (2) ELEMENT ROWS
THREE (3) ELEMENT ROWS
L1 L2 L1 L2
NOTE: WHEN INSTALLING HEATER KIT, ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEAT ER
KIT COMBINATION ON THIS UNIT'S S&R PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED ABOVE.
MARK ACCORDING TO NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED.
L1
L2
GND
PL2
PL1
2
RD
2
3
GND
RD
BL
RD
3
GN
DISCONNECT
BK
1
6
1
BK
6
5
4
WH
BR
BL
5
4
RD
TH
BL
7
8
9
7
8
9
TR
COM
INDOOR
AIR
CIRCULATOR
BLWR
SEE
NOTE
7
FUSE
24 V
3 A
CFM LED
GND
B
K
SEE
NOTE 5
DIAGNOSTIC
LED
208/230 VAC
L2
L1
R
D
DEHUM
O
40 VA
TRANSFORMER
FUSE 3 A
1
2
TH
R
24 VAC
Y2
Y1
W2
W1
G
W1 (1)
W2 (2)
W1
HEAT SEQUENCER R1
HEAT SEQUENCER R2
3
4
DIPSWITCHES
W2
Y1
Y2
G
STATUS
LED
C
+VDC (1)
RX (2)
LEARN
RX LED
R
TO
MICRO
SEE NOTE 6
INDOOR
2
1
AIR
CIRCULATOR
BLWR
TX (3)
BL
GY
BK
RD
O
CIRCULATOR BLOWER
GND
DEHUM
C
1
ECM MOTOR
HARNESS
GND (4)
TR
2
GN
3
4
5
COM
RD
BK
INTEGRATED CONTROL MODULE
GND
LOW VOLTAGE (24V)
LOW VOLTAGE FIELD
HI VOLTAGE (230V)
HI VOLTAGE FIELD
COLOR CODES:
PK PINK
BR BROWN
NOTES:
1. PLACE RED WIRE ON TRANSFORMER TERMINAL 2 FOR 208 VAC
OPERATION.
WH WHITE
BL BLUE
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED
WHEN SERVICING.
GY GRAY
RD RED
3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING
MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
YL YELLOW
OR ORANGE
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND
LOCAL CODES.
VT VIOLET
GN GREEN
BK BLACK
EQUIPMENT GND
FIELD GND
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT,
DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY (N
THERMOSTAT INPUTS)
FIELD SPLICE
6. BIAS AND TERM DIP SWITCHES MUST BE IN "ON" POSITION. RED
STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES
NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK.
RESISTER
7. DISCARD CONNECTOR PL1 WHEN INSTALLING OPTIONAL HEAT KIT
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
0140A00039 REV.C
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
10