User Guide
Audio Products
XTRA™ Full Rack Series:
XPA 2002
XPA 2002-70V
XPA 2002-100V
XPA 2003C-70V
XPA 2003C-100V
XPA 2004
Full-Rack 2-, 3-, and 4-Channel Mono and Stereo Audio
Power Amplifiers
68-783-01 Rev. C
05 11
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC Class B Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi-
dential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the
unit to ensure compliance with FCC emissions limits
For complete safety information about these products please read the Safety Compliances sheet, which is
XTRA Full Rack Power Amplifier Series • FCC Statement
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Conventions Used in this Guide
In this user guide, the following are used:
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
CAUTION: A caution indicates a potential hazard to equipment or data.
WARNING: A warning warns of things or actions that might cause injury, death, or
other severe consequences.
Copyright
© 2011 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
XTRA Full Rack Power Amplifier Series • Conventions
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Introduction ........................................................... 1
About this Guide ................................................ 1
Terms Used in this Guide................................. 1
Features.............................................................. 2
Installation............................................................. 3
Application Examples.......................................... 3
Operation................................................................ 7
Front Panel Features and Operation .................... 7
Rear Panel Features and Operation...................... 9
Bridged Mode Output................................... 15
Reference Information ...................................... 18
Specifications.................................................... 18
Part Numbers.................................................... 23
Included Parts ............................................... 23
Mounting the XTRA Series of Power Amplifiers. 25
Tabletop Use................................................. 25
UL Rack Mounting Guidelines ....................... 25
Rack Mounting ............................................. 25
XTRA Full Rack Power Amplifier Series • Contents
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
About this Guide
This guide contains information about the Extron® series of audio power amplifiers: the
XPA 2002 two-channel stereo amplifier, the XPA 2002-70V two-channel, 70 V line
distribution mono amplifier; the XPA 2002-100V two-channel, 100 V line distribution mono
amplifier; the XPA 2003C-70V three-channel, stereo 4-ohm and 8-ohm, mono 70 V line
distribution amplifier; the XPA 2003C-100V three-channel, stereo 4-ohm, 8-ohm, mono 100
V line distribution amplifier; and the XPA 2004 four-channel stereo amplifier.
The XPA series of amplifiers are full-rack width models with different power outputs:
zz XPA 2002 outputs stereo 200 watts rms per channel (4-ohm speakers) or 100 watts rms
per channel (8-ohm speakers) on channels 1 and 2. Output is 400 watts bridged mode
mono (8-ohm speaker).
zz XPA 2002-70V outputs 200 watts rms per channel on channels 1 and 2 for 70 V
systems.
zz XPA 2002-100V outputs 200 watts rms per channel on channels 1 and 2 for100 V
systems.
zz XPA 2003C-70V outputs 200 watts per channel (4-ohm speakers) or 100 watts per
channel (8-ohm speakers) on channels 1 and 2, and 200 watts (70 V line, mono) on
channel 3.
zz XPA 2003C-100V outputs 200 watts per channel (4-ohm speakers) or 100 watts per
channel (8-ohm speakers) on channels 1 and 2, and 200 watts (100 V line, mono) on
channel 3.
zz XPA 2004 outputs stereo 200 watts per channel (4-ohm speakers) or 100 watts per
channel (8-ohm speakers) on channels 1, 2, 3, and 4. Output is 400 watts per bridge in
bridged mono (8-ohm speakers) on bridge A (channels 1 and 2) and bridge B
(channels 3 and 4).
Terms Used in this Guide
The terms “amplifier” and “power amplifier” are used interchangeably in this guide to refer
to each model.
XTRA Full Rack Power Amplifier Series • Introduction
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
Extron Patented Class D Ripple Steering (CDRS™) technology — CDRS is an Extron
patented technology that provides a smooth, clean audio waveform and an improvement
in signal fidelity over conventional Class D amplifier designs. CDRS eliminates the high
frequency switching ripple characteristic of Class D amplifiers, a source of RF emissions,
which can interfere with sensitive A/V equipment such as wireless microphones.
Professional grade signal-to-noise and THD performance — Delivers professional
grade performance with 100 dB signal-to-noise ratio and THD of less than 0.1%.
Front and rear panel LED indicators —
zz Display limiter/protect status when audio clipping or amplifier malfunction occurs.
zz Indicate the presence of input signals.
Audio level adjustment — Potentiometers to adjust the audio level from = (full
attenuation) to 0 dB (no attenuation).
IEC power switch — Rear panel IEC rocker power switch.
1U full rack enclosure — The capability to deliver full-sized amplifier power in one half
the size of many comparable power amplifiers.
High pass filtering — A high pass filter (XPA 2002-70V, XPA 2002-100V,
XPA 2003C-70V, and XPA 2003C-100V only) toggle switch prevents saturation of speaker
input transformers by low frequency signals. Saturation can result in severe distortion of
the speaker output signal.
Bridged output mode — The XPA 2004 has a toggle switch to input channels 1 and 3
and output each input as a single bridged output channel at twice the power of a single
channel. Input 1 is output over the positive terminals of output channels 1 and 2. Input 3
is output over the positive terminals of output channels 3 and 4.
The XPA 2002 has a toggle switch to input channel 1 and output a single bridged output
channel at twice the power using the positive terminals of channels 1 and 2.
Convection cooled, fanless operation — Ensuring quiet reliable operation. All models
generate substantially less heat than similar power amplifer designs.
Automatic clip limiter — Detects actual onset of clipping by comparing input and output
waveforms. Gain is automatically reduced with a slow attack and fast release to eliminate
clipping. This advanced limiter design protects the speakers from clipping distortion and
offers superior sonic characteristics compared to limiters that use signal compression.
Rear panel recessed, detented level controls — Provide attenuation of input signals
for adjusting audio system gain staging as well as multi-zone applications. They are
located on the rear panel to prevent users from tampering with level adjustments.
Remote standby — Standby control that remotely shuts off all amplifier output while
power remains active at the amplifier.
Power factor correction — Features power factor correction technology that smoothes
out the high peak currents of the current draw of the amplifier, thus minimizing the
presence of high frequency harmonics on the AC power line, and therefore preventing
audible artifacts from being transmitted to other audio equipment in the system.
Class 2 wiring — The outputs from the amplifiers support Class 2 wiring that meets UL
requirements.
ENERGY STAR® qualified — All models are ENERGY STAR qualified amplifiers that
conserve energy and reduce costs.
XTRA Full Rack Power Amplifier Series • Introduction
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
This section discusses how to install the XTRA Series of full rack power amplifiers.
WARNING: Installation and service must be performed by authorized personnel
Application Examples
The following illustrations are application examples for the XPA 2002, XPA 2002-70V,
XPA 2003C-70V, and XPA 2004. Application examples for the XPA 2002-100V and
XPA 2003C-100V are very similar to the XPA 2002-70V and XPA 2003C-70V examples,
respectively.
Extron
DXP 44 HDMI
HDMl Matrix
Processor
REST
N
A
LINK
L
ATC
RS-232
4
S
T
U
P
T
U
O
TouchLink™
3
2
®
100
Y
LA
RE
LINK
ACT
Control System
UT
3
INP
1
1
2
1
IR
3
O
M
3
4
4
C
R
X
1
2
0
TX
4
L
25
1
2
IP
2
3
R
4
S
T
U
P
N
Projector
I
3
TCP/IP
R
VC
D
DV
2
D
C
OC
AM
LAPTOP
PC
ON
1
F
OF
A
Y
I
S
PL
T
E
D
U
M
EN
RE
U
SC
P
EN
N
RE
DO
SC
W
D
E
T
S
I
L
Extron
2
T
.
3
.
1
T
I
.
S
E
U
®
Laptop
DMP 64
Digital Matrix
Processor
PC
DMP 64
)
(1
2
3
-2
T
E
S
R
S
E
R
LAN
O
I/
Rx
Tx
)
2
2(
2
4
3
-2
S
3
6
R
2
1
4
1
5
x
R
Tx
O
U
T
Blu-ray
Player
RS-232
MIC/LINE INPUTS
3
P
U
T
3
MIC
V
8
4
+
S
2
3
2
6
1
4
5
1
6
5
4
R
E
W
O
P
V
12
1
.
5
A
M
A
X
Flat Panel Display
A
2002
XP
CLASS
2
WIRING
OUTPUTS
BRIDGE
A
2
E
1
BRIDG
MODE
)
BRIDGE
8
ONLY
(
ON
4
/
8
INPUTS
OFF
2
1
(BRIDGE A)
LEVEL
12
2
8
0
10
6
4
1
8
14
10
6
2
12
4
14
18
26
2
LIMITER/
REMOTE
0
PROTECT
2
1
ADNBY
ST
SIGNAL
z
H
0
-6
0
Y
B
D
5
,
9
A
77
N
A
.5
5
1
1
N
V
GREEN
AMBER
-
-
ACTIVE
ST
0
4
-2
0
0
1
Extron
O
S
A
TU
T
AUDI
A
O
R
/VIDE
PP
A
17T
XPA 2002
Two Channel
Extron
SI 28
Surface-Mount
Speakers
Power Ampliꢀer
Figure 1. XPA 2002 Application Example
XTRA Full Rack Power Amplifier Series • Installation
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Extron
XPA 2002-70V
Power Amplifer
A
2002 -70V
XP
S
2
CLASS
2
WIRING
OUTPUT
70V
1
HPF
CH
2
z
H
0
8
CH
1
z
H
0
8
S
INPUT
OFF
OFF
2
1
Projector
LEVEL
2
Projector
0
1
/
T
LIMITER
2
0
REMOTE
PROTEC
1
ADNBY
ST
SIGNAL
100-2410.3
V
A
M
5
AX/60 Hz
0
e
d
i
s
t
L
O
E
I
D
S
U
T
T
U
P
/
V
1
7
A
A
I
O
D
T
A
R
A
P
12
T
11
I
D
/
V
Y
VIDEO OU
10
C
Y
9
ASS THROUGH
P
7
C
O
E
ID
-V
S
14
8
REMOTE
VIDEO IN
13
I
D
/
V
EO
ID
2
Y
Y
23
S-
AN
V
L
RESET
R
I
D
PRIMAR
12
/
V
Y
C
R
x
T
x
K
IN
K
Y
R
C
11
I
D
-
2
32
L
L
O
/
V
O
U
T
S
A
Extron
N
Y
R
D
T
E
N
G
AC
C
3
6
O
C
E
S
9
P
U
T
x
2
5
R
O
C
T
x
E
D
5
6
V
I
T
1
4
10
S
O
E
I
D
V
O
U
T
SI 26CT
3
COMPUTER OU
P
U
T
1
2
4
S
Two-Way Ceiling
Speakers
7
8
I
5
6
7
N
P
6
U
COMPUTER IN
T
3
S
5
14
4
AUDIO INPUTS
13
1
2
4
3
12
2
11
1
10
I
9
N
P
U
T
8
Extron
S
MPX 866 A
Matrix Switcher
DVDs
Flat Panel Displays
Laptop Computers
Figure 2. XPA 2002-70V Application Example
XTRA Full Rack Power Amplifier Series • Installation
4
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232
OUTPUT
A
B
L
R
L
6
5
R
8
4
7
AUDIO3 INPUT
2
1
L
OUTPUT
D
E
T
R
I
S
RGB
R-Y
B-Y
L
3
.
2
E
,
T
T.
1
.
S
U
I
,
Y
C
6
8
DVI
RGB
RGB
7
3
4
YC
R-Y
1
2
VID
VID
Desk Microphones
5
B-Y
I
Y
N
P
U
T
100-240V
50-60Hz
Extron
IN1508
Scaling Presentation
Switcher
Laptop
Control
System
PC
RS-232
RS-232(1)
RESET
LAN
I/O
Rx
x
T
2
3
RS-232(2)
2
1
6
5
4
1
Rx
x
T
O
U
T
4
MIC/LINE INPUTS
3
P
U
T
3
MIC
V
8
4
+
S
3
2
2
6
1
4
5
1
4
6
5
POWER
12V
3A MAX
Extron
DMP 64
A
2003C -70V
XP
Digital Matrix
Processor
70V
3
CLASS
2
WIRING
OUTPUTS
4/8
2
HPF
1
CH
3
80 Hz
OFF
INPUTS
2
3
1
LEVEL
2
3
0
1
0
T
LIMITER/
PROTEC
0
REMOTE
Y
ADNB
ST
SIGNAL
X
100-2410.3
V
A
M
50/60 Hz
A
Listed
T
T
7
1
TUS
A
AUDIO/VIDEO
APP
AR
Extron
XPA 2003C 70V
Combo Power Ampliꢀer
Extron
SI 26CT
Two-Way Ceiling
Speakers
Extron
SI 28
Surface-Mount
Speakers
Figure 3. XPA 2003C-70V Application Example
XTRA Full Rack Power Amplifier Series • Installation
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Extron
SSP 7.1
Extron
CrossPoint Ultra Series
Ultra-Wideband
Matrix Switcher
Surround Sound
Processor
SSP 7.1
RS-232
SUB
Rx
Tx
WOOFER
R
BACK
OUTPUTS
L
E
R
ID
S
L
8
CENTER
7
T
N
R
O
R
F
L
6
S
T
U
5
INPUTS
ANALOG
P
T
U
4
O
R
5
3
L
RESET
2
AL
DIGIT
1
LAN
3
4
A
.5
0
z
R
G
0V
4
2
-
0
0
1
50-60H
12
R
G
8
2
11
B
H
7
1
10
6
9
5
8
B
H
S
7
T
4
U
P
V
N
S
I
T
U
3
P
T
6
U
O
2
5
V
1
4
C
N
Y
S
V
12
3
C
N
Y
S
H
11
2
1
10
9
8
7
6
S
T
5
U
P
N
I
4
3
2
1
Extron
XPA 2004
Four Channel
Power Ampliꢀer
PC
Laptop
DVD
A
2004
XP
ive
ess
ogr
/
-
R
R
E
C
O
R
D
I
N
G
RWion Cinema Pr
D-cis
DVPre
BRIDGE
3
B
4
CLASS
2
WIRING
OUTPUTS
ER
IV
)
CE
RE
BRIDGE
1
A
2
BRIDGE
S
DB
E
(
8
ONLY
8
/
BRIDG
4
MODE
B
)
BRIDGE
ONLY
A
(
8
ON
8
/
4
4
INPUTS
3
OFF
(BRIDGE B)
2
1
L
(BRIDGE A)
LEVE
4
3
DBS Receiver
0
2
0
1
/
T
R
0
E
IT
IM
4
L
3
0
REMOTE
PROTEC
2
1
ADNBY
ST
L
Left and Right
Back
SIGNA
z
H
0
/6
X
0
A
5
V
0
4
1
M
-2
A
.3
0
0
1
e
d
i
s
t
L
O
E
I
D
S
U
T
T
U
P
/
V
1
7
A
A
I
O
D
T
A
R
A
P
A
2004
XP
Left and Right
Side
BRIDGE
3
B
4
CLASS
2
WIRING
OUTPUTS
)
BRIDGE
1
A
2
BRIDGE
ONLY
(
8
8
/
BRIDGE
MODE
B
4
)
BRIDGE
ONLY
A
(
8
ON
8
/
4
4
INPUTS
3
OFF
(BRIDGE B)
2
1
L
(BRIDGE A)
LEVE
4
3
0
2
0
1
/
T
0
4
LIMITER
3
0
REMOTE
PROTEC
2
1
ADNBY
ST
L
SIGNA
Extron
XPA 2004
Four Channel
Power Ampliꢀer
z
H
0
Center
and
Subwoofer
/6
X
0
5
V
0
4
-2
0
0
1.3A MA
1
e
d
Extron
SI 28
i
s
t
L
O
E
I
D
S
U
T
D
1
7
T
I
A
O
/
V
T
U
A
R
A
P
P
A
Surface-mount
Speakers
Left and Right
Front
Figure 4. XPA 2004 Application Example
XTRA Full Rack Power Amplifier Series • Installation
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
This section discusses how to operate the XPA power amplifiers. Topics that are covered,
include:
Front Panel Features and Operation
4
1
2
GREEN
AMBER
-
-
ACTIVE
STANDBY
OVER
TEMP
LIMITER
SIGNAL
/
PROTECT
XPA 2002
3
1
2
XPA 2002,
XPA 2002-70V,
and XPA 2002-100V
Front Panel
4
1
2
3
GREEN
AMBER
-
-
ACTIVE
STANDBY
OVER
TEMP
LIMITER
SIGNAL
/
PROTECT
XPA 2003C
1
2
3
XPA 2003C-70V
and XPA 2003C-100V
Front Panel
4
1
2
3
4
GREEN
AMBER
-
-
ACTIVE
STANDBY
OVER
TEMP
LIMITER
SIGNAL
/
PROTECT
XPA 2004
XPA 2004
3
1
2
Front Panel
XTRA Full Rack Power Amplifier Series • Operation
7
Download from Www.Somanuals.com. All Manuals Search And Download.
a Power indicator LED — This LED lights:
zz Green when the amplifier is receiving full power.
zz Amber when the amplifier is in Standby mode. Standby mode turns off all
outputs from the amplifier, although the amplifier is still receiving power (see d
b Over Temp indicator LED — This LED lights red when the amplifier exceeds the
recommended operating temperature for optimal lifetime. The LED turns off after the
amplifier has cooled down sufficiently.
Should the LED light, check the following:
•
Verify that the placement of the amplifier allows for adequate ventilation and
airflow.
•
•
Avoid placing other equipment on top of the amplifier.
Verify that the operating temperature is within the specified range.
c Signal indicator LEDs (channels 1, 2, 3, and 4) — These LEDs (representing input
channels 1, 2, 3, and 4) light green only when an input signal is detected on the
corresponding channel.
NOTE: These LEDs are also located on the rear panel.
d Limiter/Protect indicator LEDs (channels 1, 2, 3, and 4) — These LEDs
(representing output channels 1, 2, 3, and 4) light red under the following
circumstances:
•
•
•
When audio clipping occurs, the corresponding channel’s LED blinks once per clip
occurrence.
When the amplifier overheats, both LEDs are lit. The LEDs are not lit after the
amplifier recovers from the overheated condition.
When DC output is detected, the amplifier is malfunctioning and the LED for the
corresponding channel is lit. The amplifier requires servicing when this event
occurs.
•
When the output leads are shorted, the LED of the corresponding channel is lit
until the short is removed.
NOTE: These LEDs are also located on the rear panel.
XTRA Full Rack Power Amplifier Series • Operation
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear Panel Features and Operation
5
CLASS 2 WIRING
OUTPUTS
BRIDGE
XPA 2002
100-240V 1.5A, 50-60 Hz
LEVEL
INPUTS
BRIDGE
MODE
REMOTE
LIMITER/
PROTECT
N15779
1
2
1
2
LISTED
1
2
ON
10
10
1
2
12
8
12
8
(BRIDGE A)
14
18
26
14
6
6
AUDIO/VIDEO
APPARATUS
17TT
GREEN
AMBER
-
-
ACTIVE
STANDBY
4
4
2
2
0
0
OFF
SIGNAL
8
/
4
(BRIDGE
8
ONLY
)
XPA 2002
Rear Panel
3
7
1
2
4
6
12
8
11
5
CLASS 2 WIRING
OUTPUTS
XPA 2002 -70V
100-240V 1.5A, 50-60 Hz
LEVEL
INPUTS
HPF
REMOTE
LIMITER/
PROTECT
70V
1
2
N15779
CH
1
CH
2
LISTED
10
10
1
2
12
8
12
8
1
2
80 Hz
80 Hz
14
18
26
14
6
6
1
2
AUDIO/VIDEO
APPARATUS
17TT
4
18
26
4
GREEN ACTIVE
-
2
2
AMBER
-
STANDBY
0
0
OFF
OFF
SIGNAL
XPA 2002-70V
Rear Panel
1
2
3
4
6
7
8
9
10
5
CLASS 2 WIRING
OUTPUTS
XPA 2002 -100V
100-240V 1.5A, 50-60 Hz
LEVEL
INPUTS
HPF
REMOTE
LIMITER/
PROTECT
100V
1
2
N15779
CH
1
CH
2
LISTED
10
10
1
2
12
8
12
8
1
2
80 Hz
80 Hz
14
18
26
14
18
26
6
6
1
2
AUDIO/VIDEO
APPARATUS
17TT
4
4
GREEN
AMBER
-
-
ACTIVE
STANDBY
2
2
0
0
OFF
OFF
SIGNAL
XPA 2002-100V
Rear Panel
1
2
4
7
8
10
6
9
3
5
100-240V 1.5A, 50-60 Hz
CLASS 2 WIRING
OUTPUTS
XPA 2003C -70V
LEVEL
INPUTS
HPF
REMOTE
LIMITER/
PROTECT
70V
3
8
/
4
N15779
CH
3
1
2
3
LISTED
1
2
10
10
10
1
2
3
80 Hz
12
8
12
8
12
8
1
2
3
14
18
26
14
14
6
6
6
AUDIO/VIDEO
APPARATUS
17TT
GREEN
AMBER
-
-
ACTIVE
STANDBY
4
4
4
2
2
2
0
0
0
OFF
SIGNAL
XPA 2003C-70V
Rear Panel
4
3
8
1
2
6
7
11
9
10
5
100-240V 1.5A, 50-60 Hz
CLASS 2 WIRING
OUTPUTS
XPA 2003C -100V
LEVEL
INPUTS
HPF
REMOTE
LIMITER/
PROTECT
100V
3
8
/
4
N15779
CH
3
1
2
3
LISTED
1
2
10
10
10
1
2
3
80 Hz
12
8
12
8
12
8
1
2
3
14
18
26
14
14
6
6
6
AUDIO/VIDEO
APPARATUS
17TT
GREEN
AMBER
-
-
ACTIVE
STANDBY
4
4
4
2
2
2
0
0
0
OFF
SIGNAL
XPA 2003C-100V
Rear Panel
1
2
3
6
7
8
9
11
10
4
XTRA Full Rack Power Amplifier Series • Operation
9
Download from Www.Somanuals.com. All Manuals Search And Download.
5
CLASS 2 WIRING
OUTPUTS
XPA 2004
100-240V 1.5A, 50-60 Hz
LEVEL
INPUTS
BRIDGE
MODE
REMOTE
BRIDGE
A
BRIDGE
B
LIMITER/
PROTECT
N15779
A
B
1
2
3
4
1
2
3
4
LISTED
1
2
3
4
10
10
10
10
ON
1
2
3
4
12
8
12
8
12
8
12
8
(BRIDGE A)
(BRIDGE B)
14
18
26
14
14
14
6
6
6
6
AUDIO/VIDEO
APPARATUS
17TT
GREEN
AMBER
-
-
ACTIVE
STANDBY
4
4
4
4
2
2
2
2
0
0
0
0
OFF
SIGNAL
8
/
4
(BRIDGE
8
ONLY
8
/
4
(BRIDGE
8
ONLY
)
)
XPA 2004
Rear Panel
1
2
3
7
11
4
6
8
12
a AC power connector — Connect a standard IEC AC power cord here for power
input (100 VAC to 240 VAC, 50/60 Hz) to the internal, autoswitching power supply.
b Power switch — This rocker switch turns power to the amplifier on or off. The off
position also disables remote standby (see d).
c Power indicator LED — This LED lights:
•
Green when the amplifier is receiving full power.
•
Amber when the amplifier is in standby mode. Standby mode turns off all
outputs from the amplifier, although the amplifier is still receiving power.
d Remote standby connector — Connecting pin 2 to ground (pin 1) places the
amplifier in standby mode. Standby mode turns off all outputs, although the amplifier
is still receiving power.
NOTE: The amplifier automatically enters standby mode after 25 minutes of
inactivity (+/- 5 minutes).
Use the included 2-pin, 3.5 mm captive screw connector to jumper the pins.
To Contact Closure Port
on Control Device
STANDBY
e Limiter/Protect indicator LEDs (channels 1, 2, 3, and 4) — These LEDs
(representing output channels 1, 2, 3, and 4) light red under four circumstances:
•
•
•
When audio clipping occurs, the LED of the corresponding channel blinks once
per clip occurrence.
When the amplifier overheats, both LEDs are lit. The LEDs are not lit after the
amplifier cools down and recovers from the overheated condition.
When DC output is detected, the amplifier is malfunctioning and the LED for
the corresponding channel is lit. When a malfunction occurs, power down the
amplifier and power it back up. If the LED still remains lit, the amplifier requires
servicing.
•
When the output leads are shorted, the LED of the corresponding channel is lit
until the short is removed.
f Signal indicator LEDs (channels 1, 2, 3 and 4) — These LEDs (representing input
channels 1, 2, 3 and 4) light green only when an input signal is detected on the
corresponding channel.
XTRA Full Rack Power Amplifier Series • Operation
10
Download from Www.Somanuals.com. All Manuals Search And Download.
g Level adjustment (channels 1, 2, 3 and 4) — Use a Tweeker or small screwdriver to
adjust the audio input level for the corresponding channel. The analog potentiometers
control the level from = (full attenuation) to 0 dB (no attenuation).
1
2
3
4
10
10
10
10
12
12
12
12
8
8
8
8
14
18
26
14
14
14
6
6
6
6
4
4
4
4
2
2
2
2
0
0
0
0
h Balanced or unbalanced stereo/mono audio input connector — Wire the
3.5 mm 3-pin captive screw connectors for balanced or unbalanced input.
Tip
Ring
Sleeve
Tip
Sleeve
Left or R
Balanced Input
Unbalanced Input
" (5 mm) MAX.
NOTE: The wires must not be tinned: tinned wire does not hold tight in the
captive screws and can break easily after several bends.
NOTE: The XPA 2004 allows for bridged output of inputs 1 (Bridge A) and
3 (Bridge B) only. Bridging effectively doubles the output power of those
inputs. Inputs 1 and 3 are the active inputs when in bridged mode while
inputs 2 and 4 are ignored (see the diagram below).
1
2
3
4
(BRIDGE A)
(BRIDGE B)
NOTE: The XPA 2002 allows for bridged output of input 1. Bridging effectively
doubles the output power of input 1 while input 2 is ignored (see the
diagram below).
1
2
(BRIDGE)
XTRA Full Rack Power Amplifier Series • Operation
11
Download from Www.Somanuals.com. All Manuals Search And Download.
i High pass filter toggle switch — Use a small screwdriver to toggle this recessed
two-position toggle switch that alternates between Off (no filtering) and 80 Hz. The
XPA 2002-70V and XPA 2002-100V have 2 switches, one for each output channel.
The XPA 2003C-70V and XPA 2003C-100V have one switch for the line distribution
output channel (channel 3). Setting the switch to 80 Hz prevents the saturation of
the speaker input transformers by low frequency signals. Saturation may result in
undesired overheating of the speaker transformers.
HPF
HPF
CH 3
CH 1 CH 2
80 Hz 80 Hz
80 Hz
OFF OFF
OFF
XPA 2002-70V
XPA 2002-100V
XPA 2003C-70V
XPA 2003C-100V
NOTE: It is recommended that the high pass filter be left in the On position
unless filtering is applied to the signal upstream of the amplifier.
j Mono audio output connector — Marked “+” and “-”, wire the included 2-pole,
5 mm screw lock captive screw connector for mono audio. See steps 1 and 2 on
the following page. Output is designed to power 70 V (XPA 2002-70V and XPA
2003C-70V) or 100 V (XPA 2002-100V and XPA 2003C-100V) line distribution
systems and is rated at 200 watts.
NOTE: You must use Class 2 wiring for this output to comply with UL
requirements.
OUTPUTS
OUTPUTS
70V
70V
3
1
2
XPA 2003C-70V
XPA 2002-70V
OUTPUTS
OUTPUTS
100V
100V
3
1
2
XPA 2003C-100V
XPA 2002-100V
CAUTION: Do not short out the “+” and “-” connectors with each other or
to ground; doing so will short the outputs and may damage the
amplifier.
XTRA Full Rack Power Amplifier Series • Operation
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 1: Strip and insert the speaker wires into the connector and
tighten the captive screws. Be sure to observe
correct polarity.
Do not tin the wires!
Step 2: Insert the wired connector into the amplifier output
and secure the locking screws on either side.
OUTPUT
70V
k Stereo audio output connector — Wire the included 4-pole, 5 mm screw lock
captive screw connector to output 2-channel (XPA 2002, XPA 2003C-70V, and XPA
2003C-100V) or 4-channel (XPA 2004) audio. Observe the correct polarities for each
channel. See the steps 1 and 2 on the following page. Output is designed to power
4 or 8 ohm speakers and is rated at 200 watts (4-ohm speaker load) or 100 watts (8-
ohm speaker load) per channel.
NOTE: You must use Class 2 wiring for this output to comply with UL
requirements.
CLASS 2 WIRING
OUTPUTS
CLASS 2 WIRING
OUTPUTS
CLASS 2 WIRING
OUTPUTS
BRIDGE
BRIDGE A
BRIDGE B
8
1
/
4
1
2
2
1
2
3
4
(BRIDGE
8
ONLY)
(BRIDGE
8
ONLY)
(BRIDGE
8
ONLY)
8
/ 4
8
/ 4
8
/ 4
XPA 2002
XPA 2003C-70V
XPA 2003C-100V
XPA 2004
CAUTION: Do not tie the “+” and “ _” outputs to each other. Doing so will
short out the outputs and may damage the amplifier.
XTRA Full Rack Power Amplifier Series • Operation
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 1: Strip and insert the speaker wires into the connector and
tighten the captive screws. Be sure to observe the
correct polarity.
Do not tin the wires!
Step 2: Insert the wired connector into the amplifier output
and secure the locking screws on either side.
2
OUTPUT
1
l Bridged output mode (XPA 2002 and XPA 2004) —
The output power of the XPA 2002 can be effectively doubled by using input channel
1 and bridging the outputs.
The output power of the XPA 2004 can be effectively doubled by using input channels
1 or 3 or both and bridging the respective outputs.
zz XPA 2002: Bridged output mode toggle switch (input channel 1) —
Use a small screwdriver to toggle the recessed two-position toggle switch to either
bridged (up) or unbridged (down) for input channel 1. Bridging takes the signal
from Input 1 and outputs the signal from the + terminals of output channels 1
and 2 (see the diagram below).
BRIDGE
MODE
ON
OFF
zz XPA 2004: Bridged output mode toggle switch (input channels 1 and 3)
— Use a small screwdriver to toggle the recessed two-position toggle switch to
either bridged (up) or unbridged (down) for the appropriate input channels (see
the diagram below).
BRIDGE
MODE
A
B
ON
OFF
Bridging takes the signal from Input 1 (A) or Input 3 (B) and outputs the combined
signals of 400 Watts from the + terminals of output channels 1 and 2 (Bridge A)
and channels 3 and 4 (Bridge B).
XTRA Full Rack Power Amplifier Series • Operation
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Bridged Mode Output
XPA 2002 bridged mono output speaker wiring
In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both
must be set to the bridged (up) position, as shown below.
For Input 1: The channel 1 “+” output terminal becomes the bridged:”+” output
terminal and the channel 2 “+” output terminal becomes the bridged “-” output terminal,
as shown below.
BRIDGE
MODE
BRIDGE
1
2
A
ON
8
/ 4
(BRIDGE 8 ONLY)
OFF
8 Ohm
On the input end, only Input 1 is used in bridged mode, as shown below.
1
2
(BRIDGE)
XPA 2002 bridged mono output using parallel speaker wiring
In bridged mode, the output mode toggle switches for Input 1 must be set to the bridged
(up) position, as shown below.
The channel 1 “+” output terminal becomes the bridged:”+” output terminal and the
channel 2 “+” output terminal becomes the bridged “-” output terminal, as shown below.
Mono +
CLASS 2 WIRING
BRIDGE
MODE
OUTPUTS
BRIDGE
8 Ohm
Total
16
ohms
16
ohms
A
1
2
ON
Load
OFF
(BRIDGE
8
ONLY)
8
/ 4
Mono –
Two 16-ohm speakers wired in parallel equal an 8-ohm load.
On the input end, only Input 1 is used in bridged mode, as shown below.
1
2
(BRIDGE)
XTRA Full Rack Power Amplifier Series • Operation
15
Download from Www.Somanuals.com. All Manuals Search And Download.
XPA 2004 bridged mono output speaker wiring
In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both
must be set to the bridged (up) position, as shown below.
For Input 1: The channel 1 “+” output terminal becomes the bridged:”+” output
terminal and the channel 2 “+” output terminal becomes the bridged “-” output terminal,
as shown below.
For Input 3: The channel 3 “+” output terminal becomes the bridged:”+” output
terminal and the channel 4 “+” output terminal becomes the bridged “-” output terminal,
as shown below.
Mono +
Mono +
CLASS 2 WIRING
BRIDGE
MODE
OUTPUTS
BRIDGE A
BRIDGE B
8 Ohm
Load
8 Ohm
Load
A
B
1
2
3
4
ON
OFF
(BRIDGE 8 ONLY)
(BRIDGE 8 ONLY)
8
/ 4
8
/ 4
Mono –
Mono –
On the input end, only Input 1 or Input 3 or both are used in bridged mode, as shown
below.
INPUTS
1
2
3
4
(BRIDGE A)
(BRIDGE B)
XPA 2004 bridged mono output using parallel speaker wiring
In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both
must be set to the bridged (up) position, as shown below.
The channel 1 “+” output terminal becomes the bridged:”+” output terminal and the
channel 2 “+” output terminal becomes the bridged “-” output terminal, as shown below.
Similarly, the channel 3 “+” output terminal becomes the bridged:”+” output terminal
and the channel 4 “+” output terminal becomes the bridged “-” output terminal, as
shown below.
Mono +
Mono +
CLASS 2 WIRING
OUTPUTS
BRIDGE
MODE
BRIDGE A
BRIDGE B
8 Ohm
Total
16
ohms
16
ohms
8 Ohm
Total
16
ohms
16
ohms
A
B
1
2
3
4
ON
Load
Load
OFF
(BRIDGE
8
ONLY)
(BRIDGE
8
ONLY)
8
/ 4
8
/ 4
Mono –
Mono –
Two 16 ohm speakers wired in parallel equal an 8 ohm load.
XTRA Full Rack Power Amplifier Series • Operation
16
Download from Www.Somanuals.com. All Manuals Search And Download.
On the input end, only Input 1 or Input 3 or both is used in bridged mode, as shown
below.
INPUTS
1
2
3
4
XTRA Full Rack Power Amplifier Series • Operation
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference
Information
This section discusses the specifications, part numbers, and accessories for the
XTRA Series of audio power amplifiers. Topics that are covered, include:
zz Part Numbers
Specifications
Audio
Voltage gain
XPA 2002, XPA 2004 ............... 23x (27 dB)
XPA 2003C-70V/100V (ch. 1 and 2)
23x (27 dB)
XPA 2002-70V, XPA 2003C-70V (ch. 3 only)
57x (35 dB)
XPA 2002-100V, XPA 2003C-100V (ch. 3 only)
81x (38 dB)
Crosstalk........................................ 75 dB (typical) @ 1 kHz
CMRR ............................................ 75 dB (typical) @ 1 kHz
Audio input
Number/signal type
XPA 2002, XPA 2002-70V, XPA 2002-100V
2 balanced/unbalanced
XPA 2003C-70V, XPA 2003C-100V
3 balanced/unbalanced
XPA 2004 ................................ 4 balanced/unbalanced
Connectors
XPA 2002, XPA 2002-70V, XPA 2002-100V
(2) 3.5 mm captive screw connectors, 3 pole
XPA 2003C-70V, XPA 2003C-100V
(3) 3.5 mm captive screw connectors, 3 pole
XPA 2004 ................................ (4) 3.5 mm captive screw connectors, 3 pole
Impedance ..................................... >10k ohms unbalanced/balanced, DC coupled
Nominal level ................................. +4 dBu (1.23 Vrms), balanced
Maximum level............................... +21 dBu (8.69 Vrms), balanced
Input sensitivity .............................. +4 dBu (1.23 Vrms)
Input signal detection threshold ..... -40 dBu 3 dB, balanced
NOTE: 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu
XTRA Full Rack Power Amplifier Series • Reference Information
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Audio output
Number/signal type
XPA 2002 ................................ 2 channels, 4 or 8 ohms; or 1 bridged mono, 8 ohms
XPA 2002-70V......................... 2 channels, 70 V
XPA 2002-100V....................... 2 channels, 100 V
XPA 2003C-70V....................... 2 channels, 4 or 8 ohms
1 channel, 70 V
XPA 2003C-100V..................... 2 channels, 4 or 8 ohms
1 channel, 100 V
XPA 2004 ................................ 4 channels, 4 or 8 ohms; or 2 bridged mono, 8 ohms
Connectors
XPA 2002 ................................ (1) 5 mm screw lock captive screw connector, 4 pole
XPA 2002-70V, XPA 2002-100V (2) 5 mm screw lock captive screw connectors, 2 pole
XPA 2003C-70V, XPA 2003C-100V
(1) 5 mm screw lock captive screw connector, 4 pole
(1) 5 mm screw lock captive screw connector, 2 pole
XPA 2004 ................................ (2) 5 mm screw lock captive screw connectors, 4 pole
NOTE: These connectors accept wires of 22 AWG to 12 AWG.
Load impedance
XPA 2002-70V......................... 25 ohms minimum
XPA 2002-100V....................... 50 ohms minimum
XPA 2003C-70V
Channel 1 or 2................... 4 ohms minimum
Channel 3.......................... 25 ohms minimum
XPA 2003C-100V
Channel 1 or 2................... 4 ohms minimum
Channel 3.......................... 50 ohms minimum
XPA 2002, XPA 2004 ............... 4 ohms (8 ohms if bridged) minimum
Amplifier type ................................ Class D
Output power
XPA 2002-70V......................... 200 watts rms per channel, 70 V, 1 kHz, 0.1% THD
XPA 2002-100V....................... 200 watts rms per channel, 100 V, 1 kHz, 0.1% THD
XPA 2003C-70V
Channel 1 or 2 (8 ohm)...... 100 watts rms per channel, 8 ohms, 1 kHz, 0.1% THD
Channel 1 or 2 (4 ohm)...... 200 watts rms per channel, 4 ohms, 1 kHz, 0.1% THD
Channel 3 (70 V output) .... 200 watts rms per channel, 70 V, 1 kHz, 0.1% THD
XPA 2003C-100V
Channel 1 or 2 (8 ohm)...... 100 watts rms per channel, 8 ohms, 1 kHz, 0.1% THD
Channel 1 or 2 (4 ohm)...... 200 watts rms per channel, 4 ohms, 1 kHz, 0.1% THD
Channel 3 (100 V output) .. 200 watts rms per channel, 100 V, 1 kHz, 0.1% THD
XPA 2002, XPA 2004 ............... 100 watts rms per channel, 8 ohms, 1 kHz, 0.05% THD
200 watts rms per channel, 4 ohms, 1 kHz, 0.05% THD
400 watts rms (bridged mono), 8 ohms, 1 kHz, 0.05% THD
Frequency response........................ 20 Hz to 20 kHz, 1 dB
THD + Noise
XPA 2002-70V, XPA 2002-100V 0.1%, 1 kHz, 3 dB below clipping
XPA 2003C-70V, XPA 2003C-100V
Channels 1 and 2: 0.1%, 20 Hz-20 kHz, 8 ohms, 3 dB below
clipping
Channel 3: 0.1%, 1 kHz, 3 dB below clipping
XPA 2002, XPA 2004 ............... 0.1%, 20 Hz to 20 kHz, 8 ohms, 3 dB below clipping
XTRA Full Rack Power Amplifier Series • Reference Information
19
Download from Www.Somanuals.com. All Manuals Search And Download.
S/N................................................. 100 dB, 20 Hz - 20 kHz, unweighted
Damping factor
XPA 2002-70V......................... >100 @ 25 ohms
XPA 2002-100V....................... >100 @ 50 ohms
XPA 2003C-70V
Channel 1 or 2................... >100 @ 8 ohms
Channel 3.......................... >100 @ 25 ohms
XPA 2003C-100V
Channel 1 or 2................... >100 @ 8 ohms
Channel 3.......................... >100 @ 50 ohms
XPA 2002, XPA 2004 ............... >100 @ 8 ohms
High pass filter
XPA 2002-70V, XPA 2003C-70V 80 Hz, 12 dB per octave rolloff for 70 V line output (switch
selectable)
XPA 2002-100V, XPA 2003C-100V
80 Hz, 12 dB per octave rolloff for 100 V line output (switch
selectable)
Control/remote — amplifier
Control port................................... (1) 3.5 mm captive screw connector, 2 pole
Pin configurations
Standby power control (contact closure)
Pin 1 = GND, pin 2 = standby
General
Power ............................................ Internal
Input: 100-240 VAC, 50-60 Hz, 1.5 A
Power consumption at 115 VAC, 60 Hz
Typical (1/8 power)
XPA 2002........................... 4 ohms (x2): 84.7 watts
8 ohms (x2): 53.4 watts
XPA 2002-70V ................... 70 V (x2): 84.5 watts
XPA 2002-100V ................. 100 V (x2): 89.6 watts
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 122.4 watts
8 ohms (x2) + 70 V: 92.2 watts
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 123.1 watts
8 ohms (x2) + 100 V: 94.4 watts
XPA 2004........................... 4 ohms (x4): 146.5 watts
8 ohms (x4): 89.3 watts
Quiescent
XPA 2002........................... 10.9 watts
XPA 2002-70V ................... 20.8 watts
XPA 2002-100V ................. 25.1 watts
XPA 2003C-70V................. 28.9 watts
XPA 2003C-100V............... 28.1 watts
XPA 2004........................... 28.7 watts
Standby................................... <1 watt (triggered by contact closure or after 25 minutes [ 5
minutes] with no signal)
XTRA Full Rack Power Amplifier Series • Reference Information
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Power consumption at 230 VAC, 50 Hz
Typical (1/8 power)
XPA 2002........................... 4 ohms (x2): 85.6 watts
8 ohms (x2): 54.4 watts
XPA 2002-70V ................... 70 V (x2): 85.6 watts
XPA 2002-100V ................. 100 V (x2): 90.4 watts
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 122.4 watts
8 ohms (x2) + 70 V: 92.9 watts
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 123.3 watts
8 ohms (x2) + 100 V: 95.3 watts
XPA 2004........................... 4 ohms (x4): 146.2 watts
8 ohms (x4): 89.9 watts
Quiescent
XPA 2002........................... 10.9 watts
XPA 2002-70V ................... 23.1 watts
XPA 2002-100V ................. 26.2 watts
XPA 2003C-70V................. 29.8 watts
XPA 2003C-100V............... 28.6 watts
XPA 2004........................... 29.0 watts
Standby................................... <1 watt (triggered by contact closure or after 25 minutes [ 5
minutes] with no signal)
Temperature/humidity .................... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%,
noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%,
noncondensing
Cooling.......................................... Convection, no vents, with heat sinks on the sides
Thermal dissipation at 115 VAC, 60 Hz
Standby................................... <1 watt (3 BTU/hr)
Idle
XPA 2002........................... 10.9 watts (37 BTU/hr)
XPA 2002-70V ................... 20.8 watts (71 BTU/hr)
XPA 2002-100V ................. 25.1 watts (86 BTU/hr)
XPA 2003C-70V................. 28.9 watts (99 BTU/hr)
XPA 2003C-100V............... 28.1 watts (96 BTU/hr)
XPA 2004........................... 28.7 watts (98 BTU/hr)
1/8 power
XPA 2002........................... 4 ohms (x2): 34.7 watts (119 BTU/hr)
8 ohms (x2): 28.4 watts (97 BTU/hr)
XPA 2002-70V ................... 70 V (x2): 34.5 watts (118 BTU/hr)
XPA 2002-100V ................. 100 V (x2): 39.6 watts (135 BTU/hr)
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr)
8 ohms (x2) + 70 V: 42.2 watts (144 BTU/hr)
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 48.1 watts (164 BTU/hr)
8 ohms (x2) + 100 V: 44.4 watts (152 BTU/hr)
XPA 2004........................... 4 ohms (x4): 46.5 watts (159 BTU/hr)
8 ohms (x4): 39.3 watts (134 BTU/hr)
Thermal dissipation at 230 VAC, 50 Hz
Standby................................... <1 watt (3 BTU/hr)
Idle
XPA 2002........................... 10.9 watts (37 BTU/hr)
XPA 2002-70V ................... 23.1 watts (79 BTU/hr)
XPA 2002-100V ................. 26.2 watts (89 BTU/hr)
XPA 2003C-70V................. 29.8 watts (102 BTU/hr)
XPA 2003C-100V............... 28.6 watts (98 BTU/hr)
XTRA Full Rack Power Amplifier Series • Reference Information
21
Download from Www.Somanuals.com. All Manuals Search And Download.
XPA 2004........................... 29.0 watts (99 BTU/hr)
1/8 power
XPA 2002........................... 4 ohms (x2): 35.6 watts (122 BTU/hr)
8 ohms (x2): 29.4 watts (100 BTU/hr)
XPA 2002-70V ................... 70 V (x2): 35.6 watts (122 BTU/hr)
XPA 2002-100V ................. 100 V (x2): 40.4 watts (138 BTU/hr)
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr)
8 ohms (x2) + 70 V: 42.9 watts (146 BTU/hr)
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 48.3 watts (165 BTU/hr)
8 ohms (x2) + 100 V: 45.3 watts (155 BTU/hr)
XPA 2004........................... 4 ohms (x4): 46.2 watts (158 BTU/hr)
8 ohms (x4): 39.9 watts (136 BTU/hr)
Protection ...................................... Clip limiting, thermal, short circuit, DC output
Indication....................................... Limiter/Protect LED indicates the onset of clip limiting, thermal
cycling, short circuit, or DC output protection
Mounting
Rack mount............................. Yes, with included mounting brackets
Enclosure type................................ Metal
Enclosure dimensions ..................... 1.7" H x 17.4" W* x 12.0" D (1U high, full rack wide)
(4.3 cm H x 44.2 cm W* x 30.5 cm D)
*Width excludes rack ears. 19.0" (48.3 cm) W with rack
ears.
Product weight............................... 9.2 lbs (4.2 kg)
Shipping weight............................. 12 lbs (6 kg)
Vibration........................................ ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety...................................... CE, c-UL, UL
Meets UL 60065, IEC 60065, and BSEN 60065 for A/V
equipment.
EMI/EMC ................................. CE, CISPR 22 Class B, CISPR 24, C-tick, EN55103-1,
EN55103-2, FCC Class B, ICES, VCCI Class B
Environmental
XPA 2002........................... Complies with the appropriate requirements of CEC, EU code
of conduct, RoHS, WEEE
All other models................. Complies with the appropriate requirements of CEC,
ENERGY STAR® (ENERGY STAR qualified amplifier), EU code
of conduct, RoHS, WEEE
MTBF ............................................. 200,000 hours
Warranty........................................ 3 years parts and labor
NOTE: All nominal levels are at 10%.
NOTE: Specifications are subject to change without notice.
XTRA Full Rack Power Amplifier Series • Reference Information
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Part Numbers
Included Parts
These items are included with each power amplifier, as indicated below.
Included parts
Replacement part
number
XPA 2002 2-channel low impedance power amplifier
60-563-01
60-883-02
60-883-12
60-848-01
or
XPA 2002-70V 2-channel 70 V power amplifier
or
XPA 2002-100V 2-channel 100 V power amplifier
or
XPA 2003C-70V 3-channel low impedance/70 V combo
power amplifier
or
XPA 2003C-100V 3-channel low impedance/100 V combo
power amplifier
60-848-11
60-563-02
or
XPA 2004 4-channel low impedance power amplifier
(1) 4-pole screw lock 5 mm captive screw plug
(XPA 2002, XPA 2003C-70V, XPA 2003C-100V)
(2) 4-pole screw lock 5 mm captive screw plug (XPA 2004)
(1) 2-pole screw lock 5 mm captive screw plug
(XPA 2003C-70V, XPA 2003C-100V)
(2) 2-pole 3.5 mm captive screw plug (XPA 2002-70V, XPA
2002-100V)
(2) 3-pole 3.5 mm captive screw plug (XPA 2002-70V, XPA
2002-100V)
(3) 3-pole 3.5 mm captive screw plug (XPA 2003C-70V, XPA
2003C-100V))
(4) 3-pole 3.5 mm captive screw plug (XPA 2004)
(1) 2-pole 3.5 mm captive screw plug
(4) Rubber feet (detached)
IEC power cord
Tweeker (small screwdriver)
User Guide
XTRA Full Rack Power Amplifier Series • Reference Information
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Optional Accessories
Description
Part Number
SI 3CT LP Ceiling speakers
42-103-03
42-103-13
42-105-02, -03
42-070-03
42-072-02, -03
42-073-02, -03
42-168-03
42-120-13
42-141-03
22-152-03
22-155-03
22-151-03
22-154-03
22-150-03
22-153-03
SI 3C LP Ceiling speakers
SI 3 Surface mount speakers (black, white)
SI 26CT Ceiling speakers
SI 26 Surface mount speakers (black, white)
SI 28 Surface mount speakers (black, white)
SF 228T Ceiling speakers
FF 120T Ceiling speakers
FF 220T Ceiling speakers
SPK14/1000 Non-Plenum 1000' (300 m) spool
SPK14P/1000 Plenum 1000' (300 m) spool
SPK16/1000 Non-Plenum 1000' (300 m) spool
SPK16P/1000 Plenum 1000' (300 m) spool
SPK18/1000 Non-Plenum 1000' (300 m) spool
SPK18P/1000 Plenum 1000' (300 m) spool
XTRA Full Rack Power Amplifier Series • Reference Information
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting
The XPA power amplifiers can be set on a table; mounted on a rack shelf; mounted under
a desk or other furniture; or mounted in the plenum space above a ceiling-mounted
projector.
Tabletop Use
Four self-adhesive rubber feet are included with the audio amplifier.
For tabletop use, attach one foot at each corner of the bottom side of the unit and place
the unit in the desired location.
UL Rack Mounting Guidelines
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of
the equipment in a rack.
1. Elevated operating ambient temperature — If installed in a closed or multi-unit
rack assembly, the operating ambient temperature of the rack environment may
be greater than room ambient temperature. Therefore, install the equipment in an
environment compatible with the maximum ambient temperature (Tma =
+122 °F/+50 °C) specified by Extron.
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow
required for safe operation of the equipment is not compromised.
3. Mechanical loading — Mount the equipment in the rack so that a hazardous
condition is not achieved due to uneven mechanical loading.
4. Circuit overloading — Connect the equipment to the supply circuit and consider
the effect that circuit overloading might have on overcurrent protection and supply
wiring. Appropriate consideration of equipment nameplate ratings should be used
when addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted
equipment. Pay particular attention to supply connections other than direct
connections to the branch circuit (for example, use of power strips).
Rack Mounting
The XTRA series of audio amplifiers are housed in rack-mountable metal enclosures with
pre-attached mounting ears for standard 19-inch racks. Mount the amplifier, as follows:
1. Disconnect all cables and power sources from the amplifier.
2. Position the amplifier in the mounting rack so that the four slots in the mounting ears
are aligned with the rack mounting holes. Use the included mounting screws to fasten
the amplifier to the rack, as shown in the following diagram.
WARNING: Never place a load exceeding 40 pounds in weight on top of the
rack-mounted amplifier.
XTRA Full Rack Power Amplifier Series • Reference Information
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Screws
A
2004
XP
BRIDGE
3
B
4
CLASS
2
WIRING
OUTPUTS
)
BRIDGE
1
A
2
BRIDGE
ONLY
(
8
8
/
BRIDGE
MODE
B
4
)
BRIDGE
ONLY
A
(
8
ON
8
/
4
4
INPUTS
3
OFF
(BRIDGE B)
2
1
(BRIDGE A)
LEVEL
4
3
0
2
0
1
0
T
4
LIMITER/
3
0
REMOTE
Y
PROTEC
2
1
ADNB
ST
SIGNAL
100-2410.3
V
A
M
5
AX/60 Hz
0
d
e
t
s
i
L
O
E
I
D
S
U
T
I
O
A
R
T
/
V
7
A
A
1
D
T
U
A
P
P
Mounting Ear
uses 5 screws
(ea side).
Figure 5. Rack Mounting the Amplifier
Rack Mounting Ventilation
Excessive heat can decrease the optimal lifetime of the power amplifier. An over temp
indicator LED on the front panel of the amplifier lights red whenever the recommended
To reduce the chances for an over temp condition, the XPA should be arranged in a rack
environment with up to a maximum of four XPAs stacked together with a minimum of
one vent space provided both above and below a stack, as shown below.
XTRA Full Rack Power Amplifier Series • Reference Information
26
Download from Www.Somanuals.com. All Manuals Search And Download.
A
2004
XP
S
BRIDGE
3
B
4
e
CLASS
2
WIRING
OUTPUT
c
)
a
BRIDGE
1
A
2
BRIDGE
(
8
ONLY
A
2004
8
XP
/
BRIDGE
MODE
B
p
4
)
Y
BRIDGE
S
A
(
8
ONL
ON
8
/
4
4
S
t
BRIDGE
3
B
4
INPUTS
3
CLASS
2
WIRING
OUTPUT
OFF
n
(BRIDGE B)
2
)
e
BRIDGE
1
A
2
BRIDGE
(
8
ONLY
A
2004
1
XP
8
/
BRIDGE
MODE
B
V
4
(BRIDGE A)
LEVEL
4
)
Y
BRIDGE
8
A
(
ONL
3
ON
8
/
0
S
2
4
BRIDGE
3
B
4
4
INPUTS
3
0
CLASS
2
WIRING
1
OUTPUT
OFF
0
4
(BRIDGE B)
2
LIMITER/
3
)
BRIDGE
0
BRIDGE
1
A
2
REMOTE
PROTECT
2
(
8
ONLY
A
2004
1
1
XP
8
/
BRIDGE
MODE
B
4
ADNBY
(BRIDGE A)
ST
LEVEL
4
)
L
Y
BRIDGE
8
A
(
ONL
SIGNA
3
ON
8
/
0
2
4
4
S
BRIDGE
3
B
4
INPUTS
0
CLASS
2
WIRING
X
1
OUTPUT
3
OFF
100-2410.3
V
A
M
50/60 Hz
A
0
(BRIDGE B)
4
2
LIMITER/
3
)
BRIDGE
0
BRIDGE
1
A
2
REMOTE
Y
PROTECT
2
(
8
ONLY
1
1
8
/
BRIDGE
MODE
B
4
ADNB
(BRIDGE A)
S
LEVEL
4
)
L
Y
BRIDGE
d
t
s
e
A
i
(
L
8
ONL
SIGNA
3
ON
O
S
8
E
U
T
I
O
A
R
I
D
T
/
T
/
V
7
A
A
0
1
D
2
4
4
U
A
INPUTS
P
P
0
X
0/60 Hz
1
3
OFF
100-2410.3
V
A
5
MA
0
4
(BRIDGE B)
2
LIMITER/
3
0
REMOTE
Y
PROTECT
2
1
1
A
2004
XP
ADNB
(BRIDGE A)
ST
LEVEL
4
L
d
e
t
i
s
SIGNA
L
3
O
E
I
D
S
U
T
I
O
A
R
T
/
V
7
0
1
D
T
2
U
A
A
BRIDGE
3
B
4
P
P
A
0
X
0/60 Hz
1
CLASS
2
WIRING
OUTPUTS
100-2410.3
V
A
5
MA
0
e
4
LIMITER/
3
0
REMOTE
Y
)
BRIDGE
PROTECT
2
BRIDGE
1
A
2
c
(
8
ONLY
1
A
XP
2004
8
E
/
BRID
D
GE
A
a
O
4
M
ST
L
B
)
d
e
t
i
s
BRIDGE
ONLY
L
p
SIGNA
A
(
8
O
ON
E
I
D
S
U
T
D
T
/
V
8
7
1
I
A
O
/
T
U
A
R
A
S
4
4
P
BRIDGE
3
B
4
P
A
INPUTS
X
0/60 Hz
CLASS
2
WIRING
3
OFF
OUTPUTS
100-2410.3
V
A
5
MA
t
(BRIDGE B)
2
)
BRIDGE
BRIDGE
1
A
2
n
A
2004
(
8
ONLY
XP
1
8
E
/
BRID
D
GE
e
O
4
M
(BRIDGE A)
LEVEL
4
B
)
d
e
t
i
s
BRIDGE
ONLY
L
V
A
(
8
3
O
ON
E
I
D
S
U
T
D
T
/
R
V
8
7
1
I
A
O
/
T
U
A
0
BRIDGE
3
B
4
A
2
4
P
4
P
A
INPUTS
3
CLASS
2
WIRING
0
OUTPUTS
1
OFF
0
4
(BRIDGE B)
)
BRIDGE
2
LIMITER/
3
BRIDGE
1
A
2
0
REMOTE
PROTECT
2
(
8
ONLY
A 2004
XP
8
1
1
E
/
BRID
D
GE
O
4
M
ADNBY
(BRIDGE A)
B
S
)
BRIDGE
ONLY
LEVEL
4
A
(
8
SIGNAL
ON
3
8
/
0
4
4
BRIDGE
3
B
4
2
INPUTS
CLASS
2
WIRING
0
1
3
OFF
OUTPUTS
100-2410.3
V
A
M
5
AX/60 Hz
0
0
(BRIDGE B)
2
4
)
LIMITER/
3
BRIDGE
1
A
2
BRIDGE
ONLY
0
REMOTE
PROTECT
2
(
8
1
8
1
E
/
BRID
D
GE
O
4
M
A
(BRIDGE A)
LEVEL
4
B
T
)
BRIDGE
ONLY
d
A
t
s
e
(
8
i
3
L
SIGNAL
ON
8
O
S
/
E
U
T
D
I
D
0
T
/
V
7
2
1
I
A
O
4
4
T
U
A
INPUTS
A
R
P
P
A
0
1
3
OFF
0
100-2410.3
V
A
M
5
AX/60 Hz
0
4
(BRIDGE B)
2
LIMITER/
3
0
REMOTE
Y
PROTECT
2
1
1
ADNB
(BRIDGE A)
ST
LEVEL
4
d
t
s
e
SIGNAL
i
3
L
O
S
E
U
T
I
O
A
R
I
D
0
T
/
V
7
2
1
D
T
U
A
A
P
P
A
0
1
100-2410.3
V
A
M
5
AX/60 Hz
0
0
e
4
LIMITER/
3
0
REMOTE
Y
PROTECT
2
c
1
A
a
ST
d
e
t
s
i
L
p
SIGNAL
O
E
D
S
T
D
I
/
V
T
7
1
I
O
A
R
U
T
U
A
A
S
P
P
A
100-2410.3
V
A
M
5
AX/60 Hz
0
t
n
e
d
e
t
s
i
L
V
O
E
S
T
I
O
A
R
I
D
T
T
/
V
7
A
A
1
U
D
U
A
P
P
Figure 6. Allow Sufficient Spacing for Adequate Ventilation
XTRA Full Rack Power Amplifier Series • Reference Information
27
Download from Www.Somanuals.com. All Manuals Search And Download.
®
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is
returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America,
Japan:
and Central America:
Extron Electronics
1001 East Ball Road
Anaheim, CA 92805
U.S.A.
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
Europe, Africa, and the Middle
East:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia
Middle East:
Extron Middle East
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Singapore
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or
mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not
authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: (714) 491-1500
Asia: +65.6383.4400
Europe: +31.33.453.4040
Japan: +81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage
during shipment. Returned units must include the serial number and a description of the problem, as well as the
name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been
advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may
not apply to you.
Extron USA - West Extron USA - East
Headquarters
Extron Europe
Extron Asia
Extron Japan
Extron China
Extron Middle East
+800.7339.8766
Inside Asia Only
+81.3.3511.7655
+81.3.3511.7656 FAX
+400.833.1568
Inside China Only
+971.4.2991800
+971.4.2991880 FAX
+800.633.9876
Inside USA/Canada Only
+800.633.9876
Inside USA/Canada Only
+800.3987.6673
Inside Europe Only
+65.6383.4400
+65.6383.4664 FAX
+86.21.3760.1568
+86.21.3760.1566 FAX
+1.714.491.1500
+1.714.491.1517 FAX
+1.919.863.1794
+1.919.863.1797 FAX
+31.33.453.4040
+31.33.453.4050 FAX
Download from Www.Somanuals.com. All Manuals Search And Download.
|