Extron electronic Car Amplifier XPA 2002 100V User Manual

User Guide  
Audio Products  
XTRAFull Rack Series:  
XPA 2002  
XPA 2002-70V  
XPA 2002-100V  
XPA 2003C-70V  
XPA 2003C-100V  
XPA 2004  
Full-Rack 2-, 3-, and 4-Channel Mono and Stereo Audio  
Power Amplifiers  
68-783-01 Rev. C  
05 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Class B Notice  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15  
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a resi-  
dential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and  
used in accordance with the instructions, may cause harmful interference to radio communications. However, there  
is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by turning the equipment off and on, the user  
is encouraged to try to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
NOTE: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the  
unit to ensure compliance with FCC emissions limits  
For complete safety information about these products please read the Safety Compliances sheet, which is  
available online at www.extron.com..  
XTRA Full Rack Power Amplifier Series • FCC Statement  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Conventions Used in this Guide  
In this user guide, the following are used:  
NOTE: A note draws attention to important information.  
TIP: A tip provides a suggestion to make working with the application easier.  
CAUTION: A caution indicates a potential hazard to equipment or data.  
WARNING: A warning warns of things or actions that might cause injury, death, or  
other severe consequences.  
Copyright  
© 2011 Extron Electronics. All rights reserved.  
Trademarks  
All trademarks mentioned in this guide are the properties of their respective owners.  
XTRA Full Rack Power Amplifier Series • Conventions  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Introduction ........................................................... 1  
About this Guide ................................................ 1  
Terms Used in this Guide................................. 1  
Features.............................................................. 2  
Installation............................................................. 3  
Application Examples.......................................... 3  
Operation................................................................ 7  
Front Panel Features and Operation .................... 7  
Rear Panel Features and Operation...................... 9  
Bridged Mode Output................................... 15  
Reference Information ...................................... 18  
Specifications.................................................... 18  
Part Numbers.................................................... 23  
Included Parts ............................................... 23  
Mounting the XTRA Series of Power Amplifiers. 25  
Tabletop Use................................................. 25  
UL Rack Mounting Guidelines ....................... 25  
Rack Mounting ............................................. 25  
XTRA Full Rack Power Amplifier Series • Contents  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
About this Guide  
This guide contains information about the Extron® series of audio power amplifiers: the  
XPA 2002 two-channel stereo amplifier, the XPA 2002-70V two-channel, 70 V line  
distribution mono amplifier; the XPA 2002-100V two-channel, 100 V line distribution mono  
amplifier; the XPA 2003C-70V three-channel, stereo 4-ohm and 8-ohm, mono 70 V line  
distribution amplifier; the XPA 2003C-100V three-channel, stereo 4-ohm, 8-ohm, mono 100  
V line distribution amplifier; and the XPA 2004 four-channel stereo amplifier.  
The XPA series of amplifiers are full-rack width models with different power outputs:  
zz XPA 2002 outputs stereo 200 watts rms per channel (4-ohm speakers) or 100 watts rms  
per channel (8-ohm speakers) on channels 1 and 2. Output is 400 watts bridged mode  
mono (8-ohm speaker).  
zz XPA 2002-70V outputs 200 watts rms per channel on channels 1 and 2 for 70 V  
systems.  
zz XPA 2002-100V outputs 200 watts rms per channel on channels 1 and 2 for100 V  
systems.  
zz XPA 2003C-70V outputs 200 watts per channel (4-ohm speakers) or 100 watts per  
channel (8-ohm speakers) on channels 1 and 2, and 200 watts (70 V line, mono) on  
channel 3.  
zz XPA 2003C-100V outputs 200 watts per channel (4-ohm speakers) or 100 watts per  
channel (8-ohm speakers) on channels 1 and 2, and 200 watts (100 V line, mono) on  
channel 3.  
zz XPA 2004 outputs stereo 200 watts per channel (4-ohm speakers) or 100 watts per  
channel (8-ohm speakers) on channels 1, 2, 3, and 4. Output is 400 watts per bridge in  
bridged mono (8-ohm speakers) on bridge A (channels 1 and 2) and bridge B  
(channels 3 and 4).  
Terms Used in this Guide  
The terms “amplifier” and “power amplifier” are used interchangeably in this guide to refer  
to each model.  
XTRA Full Rack Power Amplifier Series • Introduction  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
Extron Patented Class D Ripple Steering (CDRS™) technology — CDRS is an Extron  
patented technology that provides a smooth, clean audio waveform and an improvement  
in signal fidelity over conventional Class D amplifier designs. CDRS eliminates the high  
frequency switching ripple characteristic of Class D amplifiers, a source of RF emissions,  
which can interfere with sensitive A/V equipment such as wireless microphones.  
Professional grade signal-to-noise and THD performance — Delivers professional  
grade performance with 100 dB signal-to-noise ratio and THD of less than 0.1%.  
Front and rear panel LED indicators —  
zz Display limiter/protect status when audio clipping or amplifier malfunction occurs.  
zz Indicate the presence of input signals.  
Audio level adjustment — Potentiometers to adjust the audio level from = (full  
attenuation) to 0 dB (no attenuation).  
IEC power switch — Rear panel IEC rocker power switch.  
1U full rack enclosure — The capability to deliver full-sized amplifier power in one half  
the size of many comparable power amplifiers.  
High pass filtering — A high pass filter (XPA 2002-70V, XPA 2002-100V,  
XPA 2003C-70V, and XPA 2003C-100V only) toggle switch prevents saturation of speaker  
input transformers by low frequency signals. Saturation can result in severe distortion of  
the speaker output signal.  
Bridged output mode — The XPA 2004 has a toggle switch to input channels 1 and 3  
and output each input as a single bridged output channel at twice the power of a single  
channel. Input 1 is output over the positive terminals of output channels 1 and 2. Input 3  
is output over the positive terminals of output channels 3 and 4.  
The XPA 2002 has a toggle switch to input channel 1 and output a single bridged output  
channel at twice the power using the positive terminals of channels 1 and 2.  
Convection cooled, fanless operation — Ensuring quiet reliable operation. All models  
generate substantially less heat than similar power amplifer designs.  
Automatic clip limiter — Detects actual onset of clipping by comparing input and output  
waveforms. Gain is automatically reduced with a slow attack and fast release to eliminate  
clipping. This advanced limiter design protects the speakers from clipping distortion and  
offers superior sonic characteristics compared to limiters that use signal compression.  
Rear panel recessed, detented level controls — Provide attenuation of input signals  
for adjusting audio system gain staging as well as multi-zone applications. They are  
located on the rear panel to prevent users from tampering with level adjustments.  
Remote standby — Standby control that remotely shuts off all amplifier output while  
power remains active at the amplifier.  
Power factor correction — Features power factor correction technology that smoothes  
out the high peak currents of the current draw of the amplifier, thus minimizing the  
presence of high frequency harmonics on the AC power line, and therefore preventing  
audible artifacts from being transmitted to other audio equipment in the system.  
Class 2 wiring — The outputs from the amplifiers support Class 2 wiring that meets UL  
requirements.  
ENERGY STAR® qualified — All models are ENERGY STAR qualified amplifiers that  
conserve energy and reduce costs.  
XTRA Full Rack Power Amplifier Series • Introduction  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
This section discusses how to install the XTRA Series of full rack power amplifiers.  
WARNING: Installation and service must be performed by authorized personnel  
only (see “UL Rack Mounting Guidelines)”.  
Application Examples  
The following illustrations are application examples for the XPA 2002, XPA 2002-70V,  
XPA 2003C-70V, and XPA 2004. Application examples for the XPA 2002-100V and  
XPA 2003C-100V are very similar to the XPA 2002-70V and XPA 2003C-70V examples,  
respectively.  
Extron  
DXP 44 HDMI  
HDMl Matrix  
Processor  
REST  
N
A
LINK  
L
ATC  
RS-232  
4
S
T
U
P
T
U
O
TouchLink™  
3
2
®
100  
Y
LA  
RE  
LINK  
ACT  
Control System  
UT  
3
INP  
1
1
2
1
IR  
3
O
M
3
4
4
C
R
X
1
0
TX  
4
L
25  
1
2
IP  
2
3
R
4
S
T
U
P
N
Projector  
I
3
TCP/IP  
R
VC  
D
DV  
2
D
C
OC  
AM  
LAPTOP  
PC  
ON  
1
F
OF  
A
Y
I
S
PL  
T
E
D
U
M
EN  
RE  
U
SC  
P
EN  
N
RE  
DO  
SC  
W
D
E
T
S
I
L
Extron  
2
T
.
3
.
1
T
I
.
S
E
U
Laptop  
DMP 64  
Digital Matrix  
Processor  
PC  
DMP 64  
)
(1  
2
3
-2  
T
E
S
R
S
E
R
LAN  
O
I/  
Tx  
)
2
2(  
2
4
3
-2  
S
6
R
2
1
4
1
5
x
R
x  
O
U
T
Blu-ray  
Player  
RS-232  
MIC/LINE INPUTS  
3
P
U
T
3
MIC  
V
8
4
+
S
2
3
2
6
4
1
6
4
R
E
W
O
P
V
12  
1
.
5
A
M
A
X
Flat Panel Display  
A
2002  
XP  
CLASS  
2
WIRING  
OUTPUT
BRIDGE  
A
2
E
1
RIDG  
ODE  
)
BRIDGE  
8
ONLY  
(
ON  
4
/
8
INPUTS  
FF  
2
1
(BRIDGE A)  
LEVEL  
12  
2
8
0
10  
6
1
8
14  
10  
6
2
12  
4
14  
18  
26  
2
LIMITER/  
REMOTE  
0
PROTECT  
2
1
ADNBY  
ST  
SIGNA
z
H
0
-6  
0
Y
B
D
5
,
9
A
77  
N
A
.5  
5
1
1
N
V
GREEN  
AMBER  
-
-
ACTIVE  
ST  
0
4
-2  
0
0
1
Extron  
O
S
A
TU  
T
AUDI  
A
O
R
/VIDE  
PP  
A
17T  
XPA 2002  
Two Channel  
Extron  
SI 28  
Surface-Mount  
Speakers  
Power Ampliꢀer  
Figure 1. XPA 2002 Application Example  
XTRA Full Rack Power Amplifier Series • Installation  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extron  
XPA 2002-70V  
Power Amplifer  
A
2002 -70V  
XP  
S
2
CLASS  
2
WIRING  
OUTPUT  
70V  
1
HPF  
CH  
2
z
H
0
8
CH  
1
z
H
0
8
S
INPUT  
OFF  
OFF  
2
1
Projector  
LEVEL  
2
Projector  
0
1
/
T
LIMITER  
2
0
REMOTE  
PROTEC  
1
ADNBY  
ST  
SIGNAL  
100-2410.3  
V
A
M
5
AX
0
e
d
i
s
t
L
O
E
I
D
S
U
T
T
U
P
/
V
1
7
A
A
I
O
D
T
A
R
A
P
12  
T
11  
I
D
/
V
VIDEO OU  
10  
C
Y
9
ASS ROUGH  
P
7
O
E
D  
14  
8
RTE  
VIDEO IN  
13  
I
D
/
V
O  
ID  
2
Y
Y
23  
S-  
AN  
V
L
RESET  
I
D
PRIMAR  
12  
/
V
x
T
x
K
IN  
K
Y
R
C
11  
I
D
-
2
32  
L
L
O
/
O
U
T
S
A
Extron  
N
R
D
T
E
N
G
AC  
3
6
O
C
E
S
9
P
U
T
x
2
5
R
C
T
x
5
I
T
1
4
10  
S
O
U
T
SI 26CT  
3
COMPUTER OU  
P
U
T
1
S
Two-Way Ceiling  
Speakers  
7
I
5
7
N
P
6
U
COMPUTER I
T
3
S
5
14  
4
AUDIO INPUTS  
13  
1
3
12  
2
11  
1
10  
I
9
N
P
U
T
8
Extron  
S
MPX 866 A  
Matrix Switcher  
DVDs  
Flat Panel Displays  
Laptop Computers  
Figure 2. XPA 2002-70V Application Example  
XTRA Full Rack Power Amplifier Series • Installation  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232  
OUTPUT  
A
B
L
R
L
6
5
R
8
4
7
AUDIO3 INPU
2
1
L
OUTPUT  
D
E
T
R
I
S
RGB  
R-Y  
B-Y  
L
3
.
2
E
,
T
T.  
1
.
S
U
I
,
Y
C
6
DVI  
RGB  
RGB  
7
3
4
YC  
R-Y  
1
2
VID  
V
Desk Microphones  
5
Y  
I
Y
N
P
U
T
100-240V  
Extron  
IN1508  
Scaling Presentation  
Switcher  
Laptop  
Control  
System  
PC  
RS-232  
RS-232(
RESET  
LAN  
I/O  
Rx  
x
T
2
3
RS-232(
2
1
6
5
4
1
Rx  
x
T
O
U
T
4
MIC/LINE INPUTS  
3
P
U
T
3
MIC  
V
8
4
+
S
3
2
2
6
1
4
5
1
4
6
5
POWER  
12V  
3A MAX  
Extron  
DMP 64  
A
2003C -70V  
XP  
Digital Matrix  
Processor  
70V  
3
CLASS  
2
WIRING  
OUTPUTS  
4/8  
2
HPF  
1
CH  
3
80 Hz  
OFF  
INPUTS  
2
3
1
LEVEL  
2
3
0
1
0
T
LIMITER/  
PROTEC  
0
REMOTE  
Y
ADNB  
ST  
SIGNAL  
X
100-2410.3  
V
A
M
Listed  
T
T
7
1
TUS  
A
AUDIO/VIDEO  
APP  
AR  
Extron  
XPA 2003C 70V  
Combo Power Ampliꢀer  
Extron  
SI 26CT  
Two-Way Ceiling  
Speakers  
Extron  
SI 28  
Surface-Mount  
Speakers  
Figure 3. XPA 2003C-70V Application Example  
XTRA Full Rack Power Amplifier Series • Installation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extron  
SSP 7.1  
Extron  
CrossPoint Ultra Series  
Ultra-Wideband  
Matrix Switcher  
Surround Sound  
Processor  
SSP 7.1  
RS-232  
SUB  
Rx  
Tx  
WOOFER  
R
BACK  
OUTPUTS  
L
E
R
ID  
S
L
8
CENTER  
7
T
N
R
O
R
F
L
6
S
T
U
5
INPUTS  
ANALOG  
P
T
U
4
O
R
5
L
ET  
2
AL  
DIGIT  
1
LAN  
3
4
A
5  
0
z
R
G
0V  
4
2
-
0
0
1
50-60H  
12  
R
8
2
11  
B
H
7
1
10  
6
9
5
8
S
7
T
4
U
P
V
N
S
I
T
U
3
P
T
U
O
2
5
1
4
C
N
Y
S
V
12  
3
C
N
11  
2
1
10  
9
8
7
S
T
U
P
N
I
4
3
2
1
Extron  
XPA 2004  
Four Channel  
Power Ampliꢀer  
PC  
Laptop  
DVD  
A
2004  
XP  
ive  
ess  
ogr  
/
-
R
R
E
C
O
R
D
I
N
G
RWion Cinema Pr  
D-cis  
DVPre  
BRIDGE  
3
B
4
CLASS  
2
WIRING  
OUTPUTS  
ER  
IV  
)
CE  
RE  
BRIDGE  
1
A
2
BRIDGE  
S
DB  
E
(
8
ONLY  
8
/
BRIDG  
4
MODE  
B
)
BRIDGE  
ONLY  
A
(
8
ON  
8
/
4
4
INPUTS  
3
OFF  
(BRIDGE B)  
2
1
L
(BRIDGE A
LEVE  
4
3
DBS Receiver  
0
2
0
1
/
T
R
0
E
IT  
IM  
4
L
3
0
REMOTE  
PROTEC  
2
1
ADNBY  
ST  
L
Left and Right  
Back  
SIGNA  
z
H
0
/6  
X
0
A
5
V
0
4
1
M
-2  
A
.3  
0
0
1
e
d
i
s
t
L
O
E
I
D
S
U
T
T
U
P
/
V
1
7
A
A
I
O
D
T
A
R
A
P
A
2004  
XP  
Left and Right  
Side  
BRIDGE  
3
B
4
CLASS  
2
WIRING  
OUTPUTS  
)
BRIDGE  
1
A
2
BRIDGE  
ONLY  
(
8
8
/
BRIDGE  
MODE  
B
4
)
BRIDGE  
ONLY  
A
(
8
ON  
8
/
4
4
INPUTS  
3
OFF  
(BRIDGE B
2
1
L
(BRIDGE A
LEVE  
4
3
0
2
0
1
/
T
0
4
LIMITER  
3
0
REMOTE  
PROTEC  
2
1
ADNBY  
ST  
L
SIGNA  
Extron  
XPA 2004  
Four Channel  
Power Ampliꢀer  
z
H
0
Center  
and  
Subwoofer  
/6  
X
0
5
V
0
4
-2  
0
0
1.3A MA  
1
e
d
Extron  
SI 28  
i
s
t
L
O
E
I
D
S
U
T
D
1
7
T
I
A
O
/
V
T
U
A
R
A
P
P
A
Surface-mount  
Speakers  
Left and Right  
Front  
Figure 4. XPA 2004 Application Example  
XTRA Full Rack Power Amplifier Series • Installation  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
This section discusses how to operate the XPA power amplifiers. Topics that are covered,  
include:  
Front Panel Features and Operation  
4
1
2
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
OVER  
TEMP  
LIMITER  
SIGNAL  
/
PROTECT  
XPA 2002  
3
1
2
XPA 2002,  
XPA 2002-70V,  
and XPA 2002-100V  
Front Panel  
4
1
2
3
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
OVER  
TEMP  
LIMITER  
SIGNAL  
/
PROTECT  
XPA 2003C  
1
2
3
XPA 2003C-70V  
and XPA 2003C-100V  
Front Panel  
4
1
2
3
4
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
OVER  
TEMP  
LIMITER  
SIGNAL  
/
PROTECT  
XPA 2004  
XPA 2004  
3
1
2
Front Panel  
XTRA Full Rack Power Amplifier Series • Operation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
a Power indicator LED — This LED lights:  
zz Green when the amplifier is receiving full power.  
zz Amber when the amplifier is in Standby mode. Standby mode turns off all  
outputs from the amplifier, although the amplifier is still receiving power (see d  
b Over Temp indicator LED — This LED lights red when the amplifier exceeds the  
recommended operating temperature for optimal lifetime. The LED turns off after the  
amplifier has cooled down sufficiently.  
Should the LED light, check the following:  
Verify that the placement of the amplifier allows for adequate ventilation and  
airflow.  
Avoid placing other equipment on top of the amplifier.  
Verify that the operating temperature is within the specified range.  
c Signal indicator LEDs (channels 1, 2, 3, and 4) — These LEDs (representing input  
channels 1, 2, 3, and 4) light green only when an input signal is detected on the  
corresponding channel.  
NOTE: These LEDs are also located on the rear panel.  
d Limiter/Protect indicator LEDs (channels 1, 2, 3, and 4) — These LEDs  
(representing output channels 1, 2, 3, and 4) light red under the following  
circumstances:  
When audio clipping occurs, the corresponding channels LED blinks once per clip  
occurrence.  
When the amplifier overheats, both LEDs are lit. The LEDs are not lit after the  
amplifier recovers from the overheated condition.  
When DC output is detected, the amplifier is malfunctioning and the LED for the  
corresponding channel is lit. The amplifier requires servicing when this event  
occurs.  
When the output leads are shorted, the LED of the corresponding channel is lit  
until the short is removed.  
NOTE: These LEDs are also located on the rear panel.  
XTRA Full Rack Power Amplifier Series • Operation  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rear Panel Features and Operation  
5
CLASS 2 WIRING  
OUTPUTS  
BRIDGE  
XPA 2002  
100-240V 1.5A, 50-60 Hz  
LEVEL  
INPUTS  
BRIDGE  
MODE  
REMOTE  
LIMITER/  
PROTECT  
N15779  
1
2
1
2
LISTED  
1
2
ON  
10  
10  
1
2
12  
8
12  
8
(BRIDGE A)  
14  
18  
26  
14  
6
6
AUDIO/VIDEO  
APPARATUS  
17TT  
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
4
4
2
2
0
0
OFF  
SIGNAL  
8
/
4
(BRIDGE  
8
ONLY  
)
XPA 2002  
Rear Panel  
3
7
1
2
4
6
12  
8
11  
5
CLASS 2 WIRING  
OUTPUTS  
XPA 2002 -70V  
100-240V 1.5A, 50-60 Hz  
LEVEL  
INPUTS  
HPF  
REMOTE  
LIMITER/  
PROTECT  
70V  
1
2
N15779  
CH  
1
CH  
2
LISTED  
10  
10  
1
2
12  
8
12  
8
1
2
80 Hz  
80 Hz  
14  
18  
26  
14  
6
6
1
2
AUDIO/VIDEO  
APPARATUS  
17TT  
4
18  
26  
4
GREEN ACTIVE  
-
2
2
AMBER  
-
STANDBY  
0
0
OFF  
OFF  
SIGNAL  
XPA 2002-70V  
Rear Panel  
1
2
3
4
6
7
8
9
10  
5
CLASS 2 WIRING  
OUTPUTS  
XPA 2002 -100V  
100-240V 1.5A, 50-60 Hz  
LEVEL  
INPUTS  
HPF  
REMOTE  
LIMITER/  
PROTECT  
100V  
1
2
N15779  
CH  
1
CH  
2
LISTED  
10  
10  
1
2
12  
8
12  
8
1
2
80 Hz  
80 Hz  
14  
18  
26  
14  
18  
26  
6
6
1
2
AUDIO/VIDEO  
APPARATUS  
17TT  
4
4
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
2
2
0
0
OFF  
OFF  
SIGNAL  
XPA 2002-100V  
Rear Panel  
1
2
4
7
8
10  
6
9
3
5
100-240V 1.5A, 50-60 Hz  
CLASS 2 WIRING  
OUTPUTS  
XPA 2003C -70V  
LEVEL  
INPUTS  
HPF  
REMOTE  
LIMITER/  
PROTECT  
70V  
3
8
/
4
N15779  
CH  
3
1
2
3
LISTED  
1
2
10  
10  
10  
1
2
3
80 Hz  
12  
8
12  
8
12  
8
1
2
3
14  
18  
26  
14  
14  
6
6
6
AUDIO/VIDEO  
APPARATUS  
17TT  
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
4
4
4
2
2
2
0
0
0
OFF  
SIGNAL  
XPA 2003C-70V  
Rear Panel  
4
3
8
1
2
6
7
11  
9
10  
5
100-240V 1.5A, 50-60 Hz  
CLASS 2 WIRING  
OUTPUTS  
XPA 2003C -100V  
LEVEL  
INPUTS  
HPF  
REMOTE  
LIMITER/  
PROTECT  
100V  
3
8
/
4
N15779  
CH  
3
1
2
3
LISTED  
1
2
10  
10  
10  
1
2
3
80 Hz  
12  
8
12  
8
12  
8
1
2
3
14  
18  
26  
14  
14  
6
6
6
AUDIO/VIDEO  
APPARATUS  
17TT  
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
4
4
4
2
2
2
0
0
0
OFF  
SIGNAL  
XPA 2003C-100V  
Rear Panel  
1
2
3
6
7
8
9
11  
10  
4
XTRA Full Rack Power Amplifier Series • Operation  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5
CLASS 2 WIRING  
OUTPUTS  
XPA 2004  
100-240V 1.5A, 50-60 Hz  
LEVEL  
INPUTS  
BRIDGE  
MODE  
REMOTE  
BRIDGE  
A
BRIDGE  
B
LIMITER/  
PROTECT  
N15779  
A
B
1
2
3
4
1
2
3
4
LISTED  
1
2
3
4
10  
10  
10  
10  
ON  
1
2
3
4
12  
8
12  
8
12  
8
12  
8
(BRIDGE A)  
(BRIDGE B)  
14  
18  
26  
14  
14  
14  
6
6
6
6
AUDIO/VIDEO  
APPARATUS  
17TT  
GREEN  
AMBER  
-
-
ACTIVE  
STANDBY  
4
4
4
4
2
2
2
2
0
0
0
0
OFF  
SIGNAL  
8
/
4
(BRIDGE  
8
ONLY  
8
/
4
(BRIDGE  
8
ONLY  
)
)
XPA 2004  
Rear Panel  
1
2
3
7
11  
4
6
8
12  
a AC power connector — Connect a standard IEC AC power cord here for power  
input (100 VAC to 240 VAC, 50/60 Hz) to the internal, autoswitching power supply.  
b Power switch — This rocker switch turns power to the amplifier on or off. The off  
position also disables remote standby (see d).  
c Power indicator LED — This LED lights:  
Green when the amplifier is receiving full power.  
Amber when the amplifier is in standby mode. Standby mode turns off all  
outputs from the amplifier, although the amplifier is still receiving power.  
d Remote standby connector — Connecting pin 2 to ground (pin 1) places the  
amplifier in standby mode. Standby mode turns off all outputs, although the amplifier  
is still receiving power.  
NOTE: The amplifier automatically enters standby mode after 25 minutes of  
inactivity (+/- 5 minutes).  
Use the included 2-pin, 3.5 mm captive screw connector to jumper the pins.  
To Contact Closure Port  
on Control Device  
STANDBY  
e Limiter/Protect indicator LEDs (channels 1, 2, 3, and 4) — These LEDs  
(representing output channels 1, 2, 3, and 4) light red under four circumstances:  
When audio clipping occurs, the LED of the corresponding channel blinks once  
per clip occurrence.  
When the amplifier overheats, both LEDs are lit. The LEDs are not lit after the  
amplifier cools down and recovers from the overheated condition.  
When DC output is detected, the amplifier is malfunctioning and the LED for  
the corresponding channel is lit. When a malfunction occurs, power down the  
amplifier and power it back up. If the LED still remains lit, the amplifier requires  
servicing.  
When the output leads are shorted, the LED of the corresponding channel is lit  
until the short is removed.  
f Signal indicator LEDs (channels 1, 2, 3 and 4) — These LEDs (representing input  
channels 1, 2, 3 and 4) light green only when an input signal is detected on the  
corresponding channel.  
XTRA Full Rack Power Amplifier Series • Operation  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
g Level adjustment (channels 1, 2, 3 and 4) — Use a Tweeker or small screwdriver to  
adjust the audio input level for the corresponding channel. The analog potentiometers  
control the level from = (full attenuation) to 0 dB (no attenuation).  
1
2
3
4
10  
10  
10  
10  
12  
12  
12  
12  
8
8
8
8
14  
18  
26  
14  
14  
14  
6
6
6
6
4
4
4
4
2
2
2
2
0
0
0
0
h Balanced or unbalanced stereo/mono audio input connector — Wire the  
3.5 mm 3-pin captive screw connectors for balanced or unbalanced input.  
Tip  
Ring  
Sleeve  
Tip  
Sleeve  
Left or R  
Balanced Input  
Unbalanced Input  
" (5 mm) MAX.  
NOTE: The wires must not be tinned: tinned wire does not hold tight in the  
captive screws and can break easily after several bends.  
NOTE: The XPA 2004 allows for bridged output of inputs 1 (Bridge A) and  
3 (Bridge B) only. Bridging effectively doubles the output power of those  
inputs. Inputs 1 and 3 are the active inputs when in bridged mode while  
inputs 2 and 4 are ignored (see the diagram below).  
1
2
3
4
(BRIDGE A)  
(BRIDGE B)  
NOTE: The XPA 2002 allows for bridged output of input 1. Bridging effectively  
doubles the output power of input 1 while input 2 is ignored (see the  
diagram below).  
1
2
(BRIDGE)  
XTRA Full Rack Power Amplifier Series • Operation  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i High pass filter toggle switch — Use a small screwdriver to toggle this recessed  
two-position toggle switch that alternates between Off (no filtering) and 80 Hz. The  
XPA 2002-70V and XPA 2002-100V have 2 switches, one for each output channel.  
The XPA 2003C-70V and XPA 2003C-100V have one switch for the line distribution  
output channel (channel 3). Setting the switch to 80 Hz prevents the saturation of  
the speaker input transformers by low frequency signals. Saturation may result in  
undesired overheating of the speaker transformers.  
HPF  
HPF  
CH 3  
CH 1 CH 2  
80 Hz 80 Hz  
80 Hz  
OFF OFF  
OFF  
XPA 2002-70V  
XPA 2002-100V  
XPA 2003C-70V  
XPA 2003C-100V  
NOTE: It is recommended that the high pass filter be left in the On position  
unless filtering is applied to the signal upstream of the amplifier.  
j Mono audio output connector — Marked “+” and “-”, wire the included 2-pole,  
5 mm screw lock captive screw connector for mono audio. See steps 1 and 2 on  
the following page. Output is designed to power 70 V (XPA 2002-70V and XPA  
2003C-70V) or 100 V (XPA 2002-100V and XPA 2003C-100V) line distribution  
systems and is rated at 200 watts.  
NOTE: You must use Class 2 wiring for this output to comply with UL  
requirements.  
OUTPUTS  
OUTPUTS  
70V  
70V  
3
1
2
XPA 2003C-70V  
XPA 2002-70V  
OUTPUTS  
OUTPUTS  
100V  
100V  
3
1
2
XPA 2003C-100V  
XPA 2002-100V  
CAUTION: Do not short out the “+” and “-” connectors with each other or  
to ground; doing so will short the outputs and may damage the  
amplifier.  
XTRA Full Rack Power Amplifier Series • Operation  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 1: Strip and insert the speaker wires into the connector and  
tighten the captive screws. Be sure to observe  
correct polarity.  
Do not tin the wires!  
Step 2: Insert the wired connector into the amplifier output  
and secure the locking screws on either side.  
OUTPUT  
70V  
k Stereo audio output connector — Wire the included 4-pole, 5 mm screw lock  
captive screw connector to output 2-channel (XPA 2002, XPA 2003C-70V, and XPA  
2003C-100V) or 4-channel (XPA 2004) audio. Observe the correct polarities for each  
channel. See the steps 1 and 2 on the following page. Output is designed to power  
4 or 8 ohm speakers and is rated at 200 watts (4-ohm speaker load) or 100 watts (8-  
ohm speaker load) per channel.  
NOTE: You must use Class 2 wiring for this output to comply with UL  
requirements.  
CLASS 2 WIRING  
OUTPUTS  
CLASS 2 WIRING  
OUTPUTS  
CLASS 2 WIRING  
OUTPUTS  
BRIDGE  
BRIDGE A  
BRIDGE B  
8
1
/
4
1
2
2
1
2
3
4
(BRIDGE  
8
ONLY)  
(BRIDGE  
8
ONLY)  
(BRIDGE  
8
ONLY)  
8
/ 4  
8
/ 4  
8
/ 4  
XPA 2002  
XPA 2003C-70V  
XPA 2003C-100V  
XPA 2004  
CAUTION: Do not tie the “+” and “ _” outputs to each other. Doing so will  
short out the outputs and may damage the amplifier.  
XTRA Full Rack Power Amplifier Series • Operation  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 1: Strip and insert the speaker wires into the connector and  
tighten the captive screws. Be sure to observe the  
correct polarity.  
Do not tin the wires!  
Step 2: Insert the wired connector into the amplifier output  
and secure the locking screws on either side.  
2
OUTPUT  
1
l Bridged output mode (XPA 2002 and XPA 2004) —  
The output power of the XPA 2002 can be effectively doubled by using input channel  
1 and bridging the outputs.  
The output power of the XPA 2004 can be effectively doubled by using input channels  
1 or 3 or both and bridging the respective outputs.  
zz XPA 2002: Bridged output mode toggle switch (input channel 1) —  
Use a small screwdriver to toggle the recessed two-position toggle switch to either  
bridged (up) or unbridged (down) for input channel 1. Bridging takes the signal  
from Input 1 and outputs the signal from the + terminals of output channels 1  
and 2 (see the diagram below).  
BRIDGE  
MODE  
ON  
OFF  
zz XPA 2004: Bridged output mode toggle switch (input channels 1 and 3)  
— Use a small screwdriver to toggle the recessed two-position toggle switch to  
either bridged (up) or unbridged (down) for the appropriate input channels (see  
the diagram below).  
BRIDGE  
MODE  
A
B
ON  
OFF  
Bridging takes the signal from Input 1 (A) or Input 3 (B) and outputs the combined  
signals of 400 Watts from the + terminals of output channels 1 and 2 (Bridge A)  
and channels 3 and 4 (Bridge B).  
XTRA Full Rack Power Amplifier Series • Operation  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bridged Mode Output  
XPA 2002 bridged mono output speaker wiring  
In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both  
must be set to the bridged (up) position, as shown below.  
For Input 1: The channel 1 “+” output terminal becomes the bridged:”+” output  
terminal and the channel 2 “+” output terminal becomes the bridged “-” output terminal,  
as shown below.  
BRIDGE  
MODE  
BRIDGE  
1
2
A
ON  
8
/ 4  
(BRIDGE 8 ONLY)  
OFF  
8 Ohm  
On the input end, only Input 1 is used in bridged mode, as shown below.  
1
2
(BRIDGE)  
XPA 2002 bridged mono output using parallel speaker wiring  
In bridged mode, the output mode toggle switches for Input 1 must be set to the bridged  
(up) position, as shown below.  
The channel 1 “+” output terminal becomes the bridged:”+” output terminal and the  
channel 2 “+” output terminal becomes the bridged “-” output terminal, as shown below.  
Mono +  
CLASS 2 WIRING  
BRIDGE  
MODE  
OUTPUTS  
BIDGE  
8 Ohm  
Total  
16  
ohms  
16  
ohms  
A
1
2
ON  
Load  
OFF  
(RIDGE  
8
ONLY)  
8
/ 4  
Mono –  
Two 16-ohm speakers wired in parallel equal an 8-ohm load.  
On the input end, only Input 1 is used in bridged mode, as shown below.  
1
2
(BRIDGE)  
XTRA Full Rack Power Amplifier Series • Operation  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
XPA 2004 bridged mono output speaker wiring  
In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both  
must be set to the bridged (up) position, as shown below.  
For Input 1: The channel 1 “+” output terminal becomes the bridged:”+” output  
terminal and the channel 2 “+” output terminal becomes the bridged “-” output terminal,  
as shown below.  
For Input 3: The channel 3 “+” output terminal becomes the bridged:”+” output  
terminal and the channel 4 “+” output terminal becomes the bridged “-” output terminal,  
as shown below.  
Mono +  
Mono +  
CLASS 2 WIRING  
BRIDGE  
MODE  
OUTPUTS  
BRDGE A  
BRDGE B  
8 Ohm  
Load  
8 Ohm  
Load  
A
B
1
2
3
4
ON  
OFF  
(IDGE 8 ONLY)  
(BIDGE 8 ONLY)  
8
/ 4  
8
/ 4  
Mono –  
Mono –  
On the input end, only Input 1 or Input 3 or both are used in bridged mode, as shown  
below.  
INPUTS  
1
2
3
4
(BRIDGE A)  
(BRIDGE B)  
XPA 2004 bridged mono output using parallel speaker wiring  
In bridged mode, the output mode toggle switches for Input 1 (A) or Input 3 (B) or both  
must be set to the bridged (up) position, as shown below.  
The channel 1 “+” output terminal becomes the bridged:”+” output terminal and the  
channel 2 “+” output terminal becomes the bridged “-” output terminal, as shown below.  
Similarly, the channel 3 “+” output terminal becomes the bridged:”+” output terminal  
and the channel 4 “+” output terminal becomes the bridged “-” output terminal, as  
shown below.  
Mono +  
Mono +  
CLASS 2 WIRING  
OUTPUTS  
BRIDGE  
MODE  
BRDGE A  
BRDGE B  
8 Ohm  
Total  
16  
ohms  
16  
ohms  
8 Ohm  
Total  
16  
ohms  
16  
ohms  
A
B
1
2
3
4
ON  
Load  
Load  
OFF  
(BRIDGE  
8
ONLY)  
(BIDGE  
8
ONLY)  
8
/ 4  
8
/ 4  
Mono –  
Mono –  
Two 16 ohm speakers wired in parallel equal an 8 ohm load.  
XTRA Full Rack Power Amplifier Series • Operation  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
On the input end, only Input 1 or Input 3 or both is used in bridged mode, as shown  
below.  
INPUTS  
1
2
3
4
XTRA Full Rack Power Amplifier Series • Operation  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference  
Information  
This section discusses the specifications, part numbers, and accessories for the  
XTRA Series of audio power amplifiers. Topics that are covered, include:  
zz Part Numbers  
Specifications  
Audio  
Voltage gain  
XPA 2002, XPA 2004 ............... 23x (27 dB)  
XPA 2003C-70V/100V (ch. 1 and 2)  
23x (27 dB)  
XPA 2002-70V, XPA 2003C-70V (ch. 3 only)  
57x (35 dB)  
XPA 2002-100V, XPA 2003C-100V (ch. 3 only)  
81x (38 dB)  
Crosstalk........................................ 75 dB (typical) @ 1 kHz  
CMRR ............................................ 75 dB (typical) @ 1 kHz  
Audio input  
Number/signal type  
XPA 2002, XPA 2002-70V, XPA 2002-100V  
2 balanced/unbalanced  
XPA 2003C-70V, XPA 2003C-100V  
3 balanced/unbalanced  
XPA 2004 ................................ 4 balanced/unbalanced  
Connectors  
XPA 2002, XPA 2002-70V, XPA 2002-100V  
(2) 3.5 mm captive screw connectors, 3 pole  
XPA 2003C-70V, XPA 2003C-100V  
(3) 3.5 mm captive screw connectors, 3 pole  
XPA 2004 ................................ (4) 3.5 mm captive screw connectors, 3 pole  
Impedance ..................................... >10k ohms unbalanced/balanced, DC coupled  
Nominal level ................................. +4 dBu (1.23 Vrms), balanced  
Maximum level............................... +21 dBu (8.69 Vrms), balanced  
Input sensitivity .............................. +4 dBu (1.23 Vrms)  
Input signal detection threshold ..... -40 dBu 3 dB, balanced  
NOTE: 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV 2 dBu  
XTRA Full Rack Power Amplifier Series • Reference Information  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Audio output  
Number/signal type  
XPA 2002 ................................ 2 channels, 4 or 8 ohms; or 1 bridged mono, 8 ohms  
XPA 2002-70V......................... 2 channels, 70 V  
XPA 2002-100V....................... 2 channels, 100 V  
XPA 2003C-70V....................... 2 channels, 4 or 8 ohms  
1 channel, 70 V  
XPA 2003C-100V..................... 2 channels, 4 or 8 ohms  
1 channel, 100 V  
XPA 2004 ................................ 4 channels, 4 or 8 ohms; or 2 bridged mono, 8 ohms  
Connectors  
XPA 2002 ................................ (1) 5 mm screw lock captive screw connector, 4 pole  
XPA 2002-70V, XPA 2002-100V (2) 5 mm screw lock captive screw connectors, 2 pole  
XPA 2003C-70V, XPA 2003C-100V  
(1) 5 mm screw lock captive screw connector, 4 pole  
(1) 5 mm screw lock captive screw connector, 2 pole  
XPA 2004 ................................ (2) 5 mm screw lock captive screw connectors, 4 pole  
NOTE: These connectors accept wires of 22 AWG to 12 AWG.  
Load impedance  
XPA 2002-70V......................... 25 ohms minimum  
XPA 2002-100V....................... 50 ohms minimum  
XPA 2003C-70V  
Channel 1 or 2................... 4 ohms minimum  
Channel 3.......................... 25 ohms minimum  
XPA 2003C-100V  
Channel 1 or 2................... 4 ohms minimum  
Channel 3.......................... 50 ohms minimum  
XPA 2002, XPA 2004 ............... 4 ohms (8 ohms if bridged) minimum  
Amplifier type ................................ Class D  
Output power  
XPA 2002-70V......................... 200 watts rms per channel, 70 V, 1 kHz, 0.1% THD  
XPA 2002-100V....................... 200 watts rms per channel, 100 V, 1 kHz, 0.1% THD  
XPA 2003C-70V  
Channel 1 or 2 (8 ohm)...... 100 watts rms per channel, 8 ohms, 1 kHz, 0.1% THD  
Channel 1 or 2 (4 ohm)...... 200 watts rms per channel, 4 ohms, 1 kHz, 0.1% THD  
Channel 3 (70 V output) .... 200 watts rms per channel, 70 V, 1 kHz, 0.1% THD  
XPA 2003C-100V  
Channel 1 or 2 (8 ohm)...... 100 watts rms per channel, 8 ohms, 1 kHz, 0.1% THD  
Channel 1 or 2 (4 ohm)...... 200 watts rms per channel, 4 ohms, 1 kHz, 0.1% THD  
Channel 3 (100 V output) .. 200 watts rms per channel, 100 V, 1 kHz, 0.1% THD  
XPA 2002, XPA 2004 ............... 100 watts rms per channel, 8 ohms, 1 kHz, 0.05% THD  
200 watts rms per channel, 4 ohms, 1 kHz, 0.05% THD  
400 watts rms (bridged mono), 8 ohms, 1 kHz, 0.05% THD  
Frequency response........................ 20 Hz to 20 kHz, 1 dB  
THD + Noise  
XPA 2002-70V, XPA 2002-100V 0.1%, 1 kHz, 3 dB below clipping  
XPA 2003C-70V, XPA 2003C-100V  
Channels 1 and 2: 0.1%, 20 Hz-20 kHz, 8 ohms, 3 dB below  
clipping  
Channel 3: 0.1%, 1 kHz, 3 dB below clipping  
XPA 2002, XPA 2004 ............... 0.1%, 20 Hz to 20 kHz, 8 ohms, 3 dB below clipping  
XTRA Full Rack Power Amplifier Series • Reference Information  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S/N................................................. 100 dB, 20 Hz - 20 kHz, unweighted  
Damping factor  
XPA 2002-70V......................... >100 @ 25 ohms  
XPA 2002-100V....................... >100 @ 50 ohms  
XPA 2003C-70V  
Channel 1 or 2................... >100 @ 8 ohms  
Channel 3.......................... >100 @ 25 ohms  
XPA 2003C-100V  
Channel 1 or 2................... >100 @ 8 ohms  
Channel 3.......................... >100 @ 50 ohms  
XPA 2002, XPA 2004 ............... >100 @ 8 ohms  
High pass filter  
XPA 2002-70V, XPA 2003C-70V 80 Hz, 12 dB per octave rolloff for 70 V line output (switch  
selectable)  
XPA 2002-100V, XPA 2003C-100V  
80 Hz, 12 dB per octave rolloff for 100 V line output (switch  
selectable)  
Control/remote — amplifier  
Control port................................... (1) 3.5 mm captive screw connector, 2 pole  
Pin configurations  
Standby power control (contact closure)  
Pin 1 = GND, pin 2 = standby  
General  
Power ............................................ Internal  
Input: 100-240 VAC, 50-60 Hz, 1.5 A  
Power consumption at 115 VAC, 60 Hz  
Typical (1/8 power)  
XPA 2002........................... 4 ohms (x2): 84.7 watts  
8 ohms (x2): 53.4 watts  
XPA 2002-70V ................... 70 V (x2): 84.5 watts  
XPA 2002-100V ................. 100 V (x2): 89.6 watts  
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 122.4 watts  
8 ohms (x2) + 70 V: 92.2 watts  
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 123.1 watts  
8 ohms (x2) + 100 V: 94.4 watts  
XPA 2004........................... 4 ohms (x4): 146.5 watts  
8 ohms (x4): 89.3 watts  
Quiescent  
XPA 2002........................... 10.9 watts  
XPA 2002-70V ................... 20.8 watts  
XPA 2002-100V ................. 25.1 watts  
XPA 2003C-70V................. 28.9 watts  
XPA 2003C-100V............... 28.1 watts  
XPA 2004........................... 28.7 watts  
Standby................................... <1 watt (triggered by contact closure or after 25 minutes [ 5  
minutes] with no signal)  
XTRA Full Rack Power Amplifier Series • Reference Information  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power consumption at 230 VAC, 50 Hz  
Typical (1/8 power)  
XPA 2002........................... 4 ohms (x2): 85.6 watts  
8 ohms (x2): 54.4 watts  
XPA 2002-70V ................... 70 V (x2): 85.6 watts  
XPA 2002-100V ................. 100 V (x2): 90.4 watts  
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 122.4 watts  
8 ohms (x2) + 70 V: 92.9 watts  
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 123.3 watts  
8 ohms (x2) + 100 V: 95.3 watts  
XPA 2004........................... 4 ohms (x4): 146.2 watts  
8 ohms (x4): 89.9 watts  
Quiescent  
XPA 2002........................... 10.9 watts  
XPA 2002-70V ................... 23.1 watts  
XPA 2002-100V ................. 26.2 watts  
XPA 2003C-70V................. 29.8 watts  
XPA 2003C-100V............... 28.6 watts  
XPA 2004........................... 29.0 watts  
Standby................................... <1 watt (triggered by contact closure or after 25 minutes [ 5  
minutes] with no signal)  
Temperature/humidity .................... Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%,  
noncondensing  
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%,  
noncondensing  
Cooling.......................................... Convection, no vents, with heat sinks on the sides  
Thermal dissipation at 115 VAC, 60 Hz  
Standby................................... <1 watt (3 BTU/hr)  
Idle  
XPA 2002........................... 10.9 watts (37 BTU/hr)  
XPA 2002-70V ................... 20.8 watts (71 BTU/hr)  
XPA 2002-100V ................. 25.1 watts (86 BTU/hr)  
XPA 2003C-70V................. 28.9 watts (99 BTU/hr)  
XPA 2003C-100V............... 28.1 watts (96 BTU/hr)  
XPA 2004........................... 28.7 watts (98 BTU/hr)  
1/8 power  
XPA 2002........................... 4 ohms (x2): 34.7 watts (119 BTU/hr)  
8 ohms (x2): 28.4 watts (97 BTU/hr)  
XPA 2002-70V ................... 70 V (x2): 34.5 watts (118 BTU/hr)  
XPA 2002-100V ................. 100 V (x2): 39.6 watts (135 BTU/hr)  
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr)  
8 ohms (x2) + 70 V: 42.2 watts (144 BTU/hr)  
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 48.1 watts (164 BTU/hr)  
8 ohms (x2) + 100 V: 44.4 watts (152 BTU/hr)  
XPA 2004........................... 4 ohms (x4): 46.5 watts (159 BTU/hr)  
8 ohms (x4): 39.3 watts (134 BTU/hr)  
Thermal dissipation at 230 VAC, 50 Hz  
Standby................................... <1 watt (3 BTU/hr)  
Idle  
XPA 2002........................... 10.9 watts (37 BTU/hr)  
XPA 2002-70V ................... 23.1 watts (79 BTU/hr)  
XPA 2002-100V ................. 26.2 watts (89 BTU/hr)  
XPA 2003C-70V................. 29.8 watts (102 BTU/hr)  
XPA 2003C-100V............... 28.6 watts (98 BTU/hr)  
XTRA Full Rack Power Amplifier Series • Reference Information  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XPA 2004........................... 29.0 watts (99 BTU/hr)  
1/8 power  
XPA 2002........................... 4 ohms (x2): 35.6 watts (122 BTU/hr)  
8 ohms (x2): 29.4 watts (100 BTU/hr)  
XPA 2002-70V ................... 70 V (x2): 35.6 watts (122 BTU/hr)  
XPA 2002-100V ................. 100 V (x2): 40.4 watts (138 BTU/hr)  
XPA 2003C-70V................. 4 ohms (x2) + 70 V: 47.4 watts (162 BTU/hr)  
8 ohms (x2) + 70 V: 42.9 watts (146 BTU/hr)  
XPA 2003C-100V............... 4 ohms (x2) + 100 V: 48.3 watts (165 BTU/hr)  
8 ohms (x2) + 100 V: 45.3 watts (155 BTU/hr)  
XPA 2004........................... 4 ohms (x4): 46.2 watts (158 BTU/hr)  
8 ohms (x4): 39.9 watts (136 BTU/hr)  
Protection ...................................... Clip limiting, thermal, short circuit, DC output  
Indication....................................... Limiter/Protect LED indicates the onset of clip limiting, thermal  
cycling, short circuit, or DC output protection  
Mounting  
Rack mount............................. Yes, with included mounting brackets  
Enclosure type................................ Metal  
Enclosure dimensions ..................... 1.7" H x 17.4" W* x 12.0" D (1U high, full rack wide)  
(4.3 cm H x 44.2 cm W* x 30.5 cm D)  
*Width excludes rack ears. 19.0" (48.3 cm) W with rack  
ears.  
Product weight............................... 9.2 lbs (4.2 kg)  
Shipping weight............................. 12 lbs (6 kg)  
Vibration........................................ ISTA 1A in carton (International Safe Transit Association)  
Regulatory compliance  
Safety...................................... CE, c-UL, UL  
Meets UL 60065, IEC 60065, and BSEN 60065 for A/V  
equipment.  
EMI/EMC ................................. CE, CISPR 22 Class B, CISPR 24, C-tick, EN55103-1,  
EN55103-2, FCC Class B, ICES, VCCI Class B  
Environmental  
XPA 2002........................... Complies with the appropriate requirements of CEC, EU code  
of conduct, RoHS, WEEE  
All other models................. Complies with the appropriate requirements of CEC,  
ENERGY STAR® (ENERGY STAR qualified amplifier), EU code  
of conduct, RoHS, WEEE  
MTBF ............................................. 200,000 hours  
Warranty........................................ 3 years parts and labor  
NOTE: All nominal levels are at 10%.  
NOTE: Specifications are subject to change without notice.  
XTRA Full Rack Power Amplifier Series • Reference Information  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Part Numbers  
Included Parts  
These items are included with each power amplifier, as indicated below.  
Included parts  
Replacement part  
number  
XPA 2002 2-channel low impedance power amplifier  
60-563-01  
60-883-02  
60-883-12  
60-848-01  
or  
XPA 2002-70V 2-channel 70 V power amplifier  
or  
XPA 2002-100V 2-channel 100 V power amplifier  
or  
XPA 2003C-70V 3-channel low impedance/70 V combo  
power amplifier  
or  
XPA 2003C-100V 3-channel low impedance/100 V combo  
power amplifier  
60-848-11  
60-563-02  
or  
XPA 2004 4-channel low impedance power amplifier  
(1) 4-pole screw lock 5 mm captive screw plug  
(XPA 2002, XPA 2003C-70V, XPA 2003C-100V)  
(2) 4-pole screw lock 5 mm captive screw plug (XPA 2004)  
(1) 2-pole screw lock 5 mm captive screw plug  
(XPA 2003C-70V, XPA 2003C-100V)  
(2) 2-pole 3.5 mm captive screw plug (XPA 2002-70V, XPA  
2002-100V)  
(2) 3-pole 3.5 mm captive screw plug (XPA 2002-70V, XPA  
2002-100V)  
(3) 3-pole 3.5 mm captive screw plug (XPA 2003C-70V, XPA  
2003C-100V))  
(4) 3-pole 3.5 mm captive screw plug (XPA 2004)  
(1) 2-pole 3.5 mm captive screw plug  
(4) Rubber feet (detached)  
IEC power cord  
Tweeker (small screwdriver)  
User Guide  
XTRA Full Rack Power Amplifier Series • Reference Information  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Accessories  
Description  
Part Number  
SI 3CT LP Ceiling speakers  
42-103-03  
42-103-13  
42-105-02, -03  
42-070-03  
42-072-02, -03  
42-073-02, -03  
42-168-03  
42-120-13  
42-141-03  
22-152-03  
22-155-03  
22-151-03  
22-154-03  
22-150-03  
22-153-03  
SI 3C LP Ceiling speakers  
SI 3 Surface mount speakers (black, white)  
SI 26CT Ceiling speakers  
SI 26 Surface mount speakers (black, white)  
SI 28 Surface mount speakers (black, white)  
SF 228T Ceiling speakers  
FF 120T Ceiling speakers  
FF 220T Ceiling speakers  
SPK14/1000 Non-Plenum 1000' (300 m) spool  
SPK14P/1000 Plenum 1000' (300 m) spool  
SPK16/1000 Non-Plenum 1000' (300 m) spool  
SPK16P/1000 Plenum 1000' (300 m) spool  
SPK18/1000 Non-Plenum 1000' (300 m) spool  
SPK18P/1000 Plenum 1000' (300 m) spool  
XTRA Full Rack Power Amplifier Series • Reference Information  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting  
The XPA power amplifiers can be set on a table; mounted on a rack shelf; mounted under  
a desk or other furniture; or mounted in the plenum space above a ceiling-mounted  
projector.  
Tabletop Use  
Four self-adhesive rubber feet are included with the audio amplifier.  
For tabletop use, attach one foot at each corner of the bottom side of the unit and place  
the unit in the desired location.  
UL Rack Mounting Guidelines  
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of  
the equipment in a rack.  
1. Elevated operating ambient temperature — If installed in a closed or multi-unit  
rack assembly, the operating ambient temperature of the rack environment may  
be greater than room ambient temperature. Therefore, install the equipment in an  
environment compatible with the maximum ambient temperature (Tma =  
+122 °F/+50 °C) specified by Extron.  
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow  
required for safe operation of the equipment is not compromised.  
3. Mechanical loading — Mount the equipment in the rack so that a hazardous  
condition is not achieved due to uneven mechanical loading.  
4. Circuit overloading — Connect the equipment to the supply circuit and consider  
the effect that circuit overloading might have on overcurrent protection and supply  
wiring. Appropriate consideration of equipment nameplate ratings should be used  
when addressing this concern.  
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted  
equipment. Pay particular attention to supply connections other than direct  
connections to the branch circuit (for example, use of power strips).  
Rack Mounting  
The XTRA series of audio amplifiers are housed in rack-mountable metal enclosures with  
pre-attached mounting ears for standard 19-inch racks. Mount the amplifier, as follows:  
1. Disconnect all cables and power sources from the amplifier.  
2. Position the amplifier in the mounting rack so that the four slots in the mounting ears  
are aligned with the rack mounting holes. Use the included mounting screws to fasten  
the amplifier to the rack, as shown in the following diagram.  
WARNING: Never place a load exceeding 40 pounds in weight on top of the  
rack-mounted amplifier.  
XTRA Full Rack Power Amplifier Series • Reference Information  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Mounting Screws  
A
2004  
XP  
BRIDGE  
3
B
4
CLASS  
2
WIRING  
OUTPUTS  
)
BRIDGE  
1
A
2
BRIDGE  
ONLY  
(
8
8
/
BRIDGE  
MODE  
B
4
)
BRIDGE  
NLY  
A
(
8
ON  
8
/
4
4
INPUTS  
3
OFF  
(BRIDGE B)  
2
1
(BRIDGE A)  
LEVEL  
4
3
0
2
0
1
0
T
4
LIMITER/  
3
0
REMOTE  
Y
PROTEC  
ADNB  
ST  
SIGNAL  
100-2410.3  
V
A
M
X/
d
e
t
s
i
L
O
E
I
D
S
U
T
I
O
A
R
T
/
V
7
A
A
1
D
T
U
A
P
P
Mounting Ear  
uses 5 screws  
(ea side).  
Figure 5. Rack Mounting the Amplifier  
Rack Mounting Ventilation  
Excessive heat can decrease the optimal lifetime of the power amplifier. An over temp  
indicator LED on the front panel of the amplifier lights red whenever the recommended  
operating temperature has been exceeded (see “Front Panel Features and Operation).  
To reduce the chances for an over temp condition, the XPA should be arranged in a rack  
environment with up to a maximum of four XPAs stacked together with a minimum of  
one vent space provided both above and below a stack, as shown below.  
XTRA Full Rack Power Amplifier Series • Reference Information  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
2004  
XP  
S
BRIDGE  
3
B
4
e
CLASS  
2
WIRING  
OUTPUT  
c
)
a
BRIDGE  
1
A
2
BRIDGE  
(
8
ONLY  
A
2004  
8
XP  
/
BRIDGE  
MODE  
B
p
4
)
Y
BRIDGE  
S
A
(
8
ONL  
ON  
8
/
4
4
S
t
BRIDGE  
3
B
4
INPUTS  
3
CLASS  
2
WIRING  
OUTPUT  
OFF  
n
(BRIDGE B)  
2
)
e
BRIDGE  
1
A
2
BRIDGE  
(
8
ONLY  
A
2004  
1
XP  
8
/
BRIDGE  
MODE  
B
V
4
(BRIDGE A
LEVEL  
4
)
Y
BRIDGE  
8
A
(
ONL  
3
ON  
8
/
0
S
2
4
BRIDGE  
3
B
4
4
INPUTS  
3
0
CLASS  
2
WIRING  
1
OUTPUT  
OFF  
0
4
(BRIDGE B)  
2
LIMITER/  
3
)
BRIDGE  
0
BRIDGE  
1
A
2
REMOTE  
PROTECT  
(
8
ONLY  
A
2004  
1
XP  
8
/
BRIDGE  
MODE  
B
4
ADNBY  
(BRIDGE A)  
ST  
LEVEL  
4
)
L
Y
BRIDGE  
8
A
(
ONL  
SIGNA  
3
ON  
8
/
0
2
4
4
S
BRIDGE  
3
B
4
INPUTS  
0
CLASS  
2
WIRING  
X
1
OUTPUT  
3
OFF  
100-2410.3  
V
A
M
0
(BRIDGE B)  
4
2
LIMITER/  
3
)
BRIDGE  
0
BRIDGE  
1
A
2
REMOTE  
Y
PROTECT  
2
(
8
NLY  
1
8
/
BRIDGE  
MODE  
B
4
ADNB  
(BRIDGE A)  
S
LEVEL  
4
)
L
Y
BRIDGE  
d
t
s
e
A
i
(
L
8
ONL  
SIGNA  
3
ON  
O
S
8
E
U
T
I
O
A
R
I
D
T
/
T
/
V
7
A
A
0
1
D
2
4
4
U
A
INPUTS  
P
P
0
X
1
3
OFF  
100-2410.3  
V
A
5
MA  
0
4
(BRIDGE B)  
2
LIMITER/  
3
0
REMOTE  
Y
PROTECT  
2
1
A
2004  
XP  
ADNB  
(BRIDGE A)  
ST  
LEVEL  
4
L
d
e
t
i
s
SIGNA  
L
3
O
E
I
D
S
U
T
I
O
A
R
T
/
V
7
0
1
D
T
2
U
A
A
BRIDGE  
3
B
4
P
P
A
0
X
1
CLASS  
2
WIRING  
OUTPUTS  
100-2410.3  
V
A
5
MA  
0
e
4
LIMITER/  
3
0
REMOTE  
Y
)
BRIDGE  
PROTECT  
2
BRIDGE  
1
A
2
c
(
8
NLY  
A
XP  
2004  
8
E
/
BRID  
D
GE  
A
a
O
4
M
ST  
L
B
)
d
e
t
i
s
BRIDGE  
ONLY  
L
p
SIGNA  
A
(
8
O
ON  
E
I
D
S
U
T
D
T
/
V
8
7
1
I
A
O
/
T
U
A
R
A
S
4
4
P
BRIDGE  
3
B
4
P
A
INPUTS  
X
CLASS  
2
WIRING  
3
OFF  
OUTPUTS  
100-2410.3  
V
A
t
(BRIDGE B
2
)
BRIDGE  
BRIDGE  
1
A
2
n
A
2004  
(
8
ONLY  
XP  
1
8
E
/
BRID  
D
GE  
e
O
4
M
(BRIDGE A)  
LEVEL  
4
B
)
d
e
t
i
s
BRIDGE  
ONLY  
L
V
A
(
8
3
O
ON  
E
I
D
S
U
T
D
T
/
R
V
8
7
1
I
A
O
/
T
U
A
0
BRIDGE  
3
B
4
A
2
4
P
4
P
A
INPUTS  
3
CLASS  
2
WIRING  
0
OUTPUTS  
1
OFF  
0
4
(BRIDGE )  
)
BRIDGE  
2
LIMITER/  
3
BRIDGE  
1
A
2
0
REMOTE  
PROTECT  
(
8
NLY  
A 2004  
XP  
8
1
E
/
BRID  
D
GE  
O
4
M
ADNBY  
(BRIDGE A)  
B
S
)
BRIDGE  
ONLY  
LEVEL  
4
A
(
8
SIGNAL  
ON  
3
8
/
0
4
4
BRIDGE  
3
B
4
2
INPUTS  
CLASS  
2
WIRING  
0
1
3
OFF  
OUTPUTS  
100-2410.3  
V
A
0
(BRIDGE B)  
2
4
)
LIMITER/  
3
BRIDGE  
1
A
2
BRIDGE  
ONLY  
0
REMOTE  
PROTECT  
(
8
1
8
E
/
BRID  
D
GE  
O
4
M
A
(BRIDGE A)  
LEVEL  
4
B
T
)
BRIDGE  
ONLY  
d
A
t
s
e
(
8
i
3
L
SIGNAL  
ON  
8
O
S
/
E
U
T
D
I
D
0
T
/
V
7
2
1
I
A
O
4
4
T
U
A
INPUTS  
A
R
P
P
A
0
1
3
OFF  
0
100-2410.3  
V
A
M
4
(BRIDGE B)  
2
LIMITER/  
3
0
REMOTE  
Y
PROTECT  
2
1
ADNB  
(BRIDGE A)  
ST  
LEVEL  
4
d
t
s
e
SIGNAL  
i
3
L
O
S
E
U
T
I
O
A
R
I
D
0
T
/
V
7
2
1
D
T
U
A
A
P
P
A
0
1
100-2410.3  
V
A
M
AX
0
e
4
LIMITER/  
3
0
REMOTE  
Y
PROTECT  
c
A
a
ST  
d
e
t
s
i
L
p
SIGNAL  
O
E
D
S
T
D
I
/
V
T
7
1
I
O
A
R
U
T
U
A
A
S
P
P
A
100-2410.3  
V
A
M
t
n
e
d
e
t
s
i
L
V
O
E
S
T
I
O
A
R
I
D
T
T
/
V
7
A
A
1
U
D
U
A
P
P
Figure 6. Allow Sufficient Spacing for Adequate Ventilation  
XTRA Full Rack Power Amplifier Series • Reference Information  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Extron Warranty  
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years  
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty  
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,  
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is  
returned within the warranty period, with proof of purchase and description of malfunction to:  
USA, Canada, South America,  
Japan:  
and Central America:  
Extron Electronics  
1001 East Ball Road  
Anaheim, CA 92805  
U.S.A.  
Extron Electronics, Japan  
Kyodo Building, 16 Ichibancho  
Chiyoda-ku, Tokyo 102-0082  
Japan  
Europe, Africa, and the Middle  
East:  
Extron Europe  
Hanzeboulevard 10  
3825 PH Amersfoort  
The Netherlands  
China:  
Extron China  
686 Ronghua Road  
Songjiang District  
Shanghai 201611  
China  
Asia:  
Extron Asia  
Middle East:  
Extron Middle East  
135 Joo Seng Road, #04-01  
PM Industrial Bldg.  
Singapore 368363  
Singapore  
Dubai Airport Free Zone  
F12, PO Box 293666  
United Arab Emirates, Dubai  
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or  
mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not  
authorized by Extron.  
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return  
Authorization) number. This will begin the repair process.  
USA: (714) 491-1500  
Asia: +65.6383.4400  
Europe: +31.33.453.4040  
Japan: +81.3.3511.7655  
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage  
during shipment. Returned units must include the serial number and a description of the problem, as well as the  
name of the person to contact in case there are any questions.  
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,  
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,  
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been  
advised of such damage.  
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may  
not apply to you.  
Extron USA - West Extron USA - East  
Headquarters  
Extron Europe  
Extron Asia  
Extron Japan  
Extron China  
Extron Middle East  
+800.7339.8766  
Inside Asia Only  
+81.3.3511.7655  
+81.3.3511.7656 FAX  
+400.833.1568  
Inside China Only  
+971.4.2991800  
+971.4.2991880 FAX  
+800.633.9876  
Inside USA/Canada Only  
+800.633.9876  
Inside USA/Canada Only  
+800.3987.6673  
Inside Europe Only  
+65.6383.4400  
+65.6383.4664 FAX  
+86.21.3760.1568  
+86.21.3760.1566 FAX  
+1.714.491.1500  
+1.714.491.1517 FAX  
+1.919.863.1794  
+1.919.863.1797 FAX  
+31.33.453.4040  
+31.33.453.4050 FAX  
© 2011 Extron Electronics. All rights reserved. www.extron.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EdgeStar Humidifier EAC421 User Manual
Edirol Musical Instrument UA 1000 User Manual
Eiki Projector LC SXG400 User Manual
Esoteric CD Player D00816700B User Manual
Fellowes Paper Shredder PS 62C User Manual
FOCUS Enhancements Network Router FS453 User Manual
Frigidaire Dishwasher 675E+11 User Manual
Gemini CD Player CDJ 01 User Manual
GE Monogram Drill ZGG36N31YSS36 User Manual
Global Machinery Company Saw LS1620 User Manual