Gianni Industries Switch BTS 200 User Manual

BTS Touch Sensitive Switch  
Installation Instruction  
Specifications  
BTS-486  
Relay output  
Relay output  
(Touched)  
(Touched)  
Specifications  
Com. N. C.  
Com. N. O.  
Setting JP  
1
30  
1
2
3
4
5
SPDT relay rating: 3A@ 125V~  
Current: 60mA~100mA@12V DC  
Power input :12~24 V DC  
Relay output  
Relay output  
Com. N. O.  
Com. N. C.  
Operating Temper.: - 20~+70ºC  
JP setting:  
(Light is lighting)  
JP1: Relay output model  
JP2: LED lighting or blinking setting  
Jp3~5: LED brightness setting  
(Light is blinking.)  
Relay  
(Red)  
(Green)  
(Touched)  
BTS-300 , 400-ANSI  
(Green)  
(Red)  
(Touched)  
(Touched)  
Relay contact output  
(free voltage contact)  
(Green)  
Relay  
12~24VDC power input  
(Green)  
(Touched)  
Setting JP  
Timer delay  
(Seconds)  
Relay output model  
control and LED  
brightness setting  
(Red)  
(Touched)  
(Touched)  
1
30  
(Red)  
Connecting Diagram  
Control Device(Outdoor)  
N.C.  
Relay output  
Fig. A  
BTS-200 adds an extra  
trigger for remote control  
purpose; it has the same  
effect as touching motion.  
Com.  
control  
N.O.  
T h e d i a g r a m s b e l o w i l l u s t r a t e t h e t w o  
recommended ways of installing the BTS Touch  
Sensitive Switch and access control devices after  
power input (power on).  
TR  
TR  
(Trigger)  
Locking Device  
(fail-safe)  
N.C.  
Com.  
Power Supply  
N.O.  
Shorten  
In Fig. A, BTS directly controls the release of fail-  
safe(Power to Lock) locking device.  
BTS Touch Sensitive Switch  
(Indoor)  
Control Device(Outdoor)  
N.C.  
Relay output  
Fig. B  
BTS-200 adds an extra  
trigger for remote control  
purpose; it has the same  
effect as touching motion.  
Com.  
control  
N.O.  
TR  
TR  
In Fig. B, For fail-secure(Power to Unlock) locking  
(Trigger)  
devices the contact on control device should be sat  
to N.O. The relay time of BTS is the same as the  
release time of locking device in both cases.  
Locking Device  
(fail-secure)  
N.C.  
Com.  
Power Supply  
N.O.  
Shorten  
BTS Touch Sensitive Switch  
(Indoor)  
IMPORTANT NOTICE:  
1. It is important to take extra notice on the maximum voltage and current output that the rated of relay contact to be used.  
2.Make sure that the "+" and "-" wire are connected correctly.  
Copyright © 2008 GIANNI INDUSTRIES, INC. All rights reserved.  
P-MU-BTS200 Ver. L Published on 2008.06.09  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Projector LC NB3EU User Manual
Euro Pro Vacuum Cleaner NV31 User Manual
Fisher Paykel Oven BI600ED User Manual
Fisher Paykel Refrigerator RB36S User Manual
Fisher Price Baby Gym 73739 User Manual
Frigidaire Microwave Oven 316495002 User Manual
Garland Fryer 36E User Manual
GE TV Receiver 05GP005 User Manual
GE Washer S2200 User Manual
GE Water System GXFM07HBL User Manual