EASIPROX
Waterproof Standalone Proximity Reader
EASIPROX
EASIPROX-ANSI
I.
Product Characteristic:
Easiprox has a 2000 cards capacity and a reading time of 0.5-second max.
Fully Programmable via Master card
Electronics potted with epoxy compound applications
Aesthetic and inconspicuous design
Suitable for fully weatherized indoor/outdoor
Non-volatile memory stores all programmed information for at least 10 years, even in the
event of total power failure.
II.
Specifications:
12Vdc or ac
Operating Voltage
Average 45mA, Peak 70mA @ 12Vdc
Current Draw
125 KHz
Transmitting Frequency
2000 Proximity cards/tokens and PIN codes
Memory Volume
10~15 cm (Depending on local installation conditions)
Read Range
3A MAX @24Vdc
Relay Electric Current
Strike Time: 0.7~42 seconds (adjustable)
Relocking timer
Em-400x 64-bit standard R/O or compatible
Format
ABS (UL94V0)
Case Material
Dark gray
Color
-20~+70℃
Operating Temperature
5~95% relative humidity non-condensing
Ambient Humidity
3 LED display with audible indication (Red/Yellow/Green)
Visual Signals
Meet CE requirement
EMC
Copyright © Gianni Industries, Inc. All Rights Reserved.
P-MU-EASIPROX Ver. B Published on 2008.02.12
Page: 1/ 4
Download from Www.Somanuals.com. All Manuals Search And Download.
V.
Operation Instruction
WARNING: Please read all of operation instruction before proceeding.
Setting Master Card
If the GREEN and YELLOW lamps are flashing, it indicates that the memory is empty and
that there is no Master Card. All programming is done by using this Master Card.
Add Cards
Read the Master Card once→ Only the GREEN lamp wills light→ Wait for the GREEN
lamp to start flashing→ The Easiprox is now in the ADD state.
In this state every Card presented to the Easiprox will operate the relay and be added to
memory. Read the Master Card to return to the Stand-by state.
Delete Cards
Read the Master Card twice with a time between reads of less than 2 seconds→ The
RED lamp will light→ Wait for the RED lamp to start flashing→ The Easiprox is now in
the DELETE state.
In this state every Card that is presented to the reader will be deleted from the system
memory. (Cards can now also be deleted by using the optional Card Simulator.). Once
the Card or a group of Cards have been deleted, read the Master Card to return to the
Stand-by state.
Clear Memory
Read the Master Card three times with a time between reads of less than 2 seconds→
The YELLOW and RED lamps will light→ Wait for the YELLOW and RED lamps to start
flashing→ The Easiprox is now in the CLEAR MEMORY state.
Now present any Card except the Master Card to the reader and all memory will be
cleared. Alternatively, read the Master Card to abort this function. Once the memory is
cleared the YELLOW and GREEN lamps will flash to indicate that the memory is empty.
Totally reset
Power off→ Shorted the Clear Memory (Black cable)→ Power on→ Wait for the
YELLOW and RED lamps to start flashing(remove the black cable)→ Once the
memory is cleared the YELLOW and GREEN lamps will flash to indicate that the memory
is empty.
Time Adjust
This function sets the relay operating time for a push-button input and a valid card read.
Read the Master Card 4 times with a time between reads of less than 2 seconds→ All
the lamps will go off→ Wait for the YELLOW lamp to start flashing→ The Easiprox is
now in the TIME ADJUST state and each flash of the YELLOW lamp equates to 0.7
second of relay operation time.
Once the desired time is reached (max 42 seconds), read the Master Card to store the
time and return to the Stand-by state. If programming mode is required simply allow the
YELLOW lamp to flash until it stops automatically (after 61 flashes). The unit will now be
in programming mode.
Copyright © Gianni Industries, Inc. All Rights Reserved.
P-MU-EASIPROX Ver. B Published on 2008.02.12
Page: 3/ 4
Download from Www.Somanuals.com. All Manuals Search And Download.
Card Simulator / Programmer (optional)
The Card Simulator allows adding and removing any card/card number from the reader
memory when the card is lost or not available. One unit can be utilized at different sites
but for security reasons it will operate only in conjunction with the Master Card.
The Card Simulator / Programmer cannot be used to gain access. It will only operate
together with the reader's MASTER card
¾
Setting Card Number
Hold the On/Off button down.
Use the RIGHT ARROW key to move the cursor to the digit to be changed.
Use the UP ARROW key to change the number at the cursor.
Repeat the above until all the digits of the number are correct.
This number is stored in memory and the On/Off button may now be released.
¾
Battery
The unit is powered by a PP3 9V battery. Undo the 2 screws at the back of the unit to
gain access to the battery.
¾
Deleting Cards
The MASTER card must be used to put the reader into the Delete mode.
RED lamp flashes
Place the Card Simulator close to the reader
Hold down the On/Off button and check the displayed number
Press the Send button
The GREEN lamp will flash to verify that the selected number is deleted and then the
RED lamp will continue flashing.
Once the card or a group of cards have been deleted, read the Master Card to return to
the RUN state.
¾
Adding Cards
The MASTER card must be used to put the reader into the Add mode.
GREEN lamp flashes
Place the Card Simulator close to the reader
Hold down the On/Off button and check the displayed number
Press the Send button
The GREEN lamp will go steady and the relay will operate to verify that the selected
number is added. The GREEN lamp will then continue flashing.
Once the card or a group of cards have been added, read the Master Card to return to
the stand-by state.
Copyright © Gianni Industries, Inc. All Rights Reserved.
P-MU-EASIPROX Ver. B Published on 2008.02.12
Page: 4/ 4
Download from Www.Somanuals.com. All Manuals Search And Download.
|