EB-262 Electric Dropbolt  
Dimension  
35  
3
25.5  
121  
140  
262  
166  
Unit: mm  
Statement  
3
The EB- 262 electric dropbolt has a logic circuit and this  
position ball design keeps the bolt retracted while the door is  
not locked on strike plate until the door closed properly. This  
design is for security purpose, which solves problem of  
improper door positioning.  
41  
Smart Circuitry  
The vandal resistant circuitry means the door close sensor  
can't be fooled into projecting the electric dropbolt unless the  
door is actually closed. The reed sensor automatically  
disconnects after the bolt is projected to enhance security of  
the lock.  
Specifications  
Fail-Safe Version (Power to Lock)  
Power Input: 12 V DC  
Voltage Tolerance: 10%  
Current Draw:  
Pull in: 0.9A, Holding: 0.3A@12V DC  
(at temperature 20°C(  
Magnetic bolt status output (SPDT rated 3A@30VDC)  
indicates bolt is in a locked or unlocked status.  
Operating Temperature: -10~+45C  
Humidity: 0~95% non-condensing.  
Tested to 500000 cycles.  
Built-in logical circuitry  
Auto-relocking Time Delay : 0, 3 ,6 ,9seconds  
Face Plate Material: stainless steel  
Weight )Approx.(: 1.2 Kg  
Auto-detective circuitry  
The unique intelligent logic circuit in GEM's electric  
dropbolts keeps the bolt retracted whilst the door is unlocked  
until the door is properly closed. This feature ensures the bolt  
will not extend if the door is improperly aligned.  
Double Acting Doors  
EB-262 Electric dropbolt is specially designed for use on  
double swinging doors. They can also be installed on both out  
and in-swinging doors.  
Out-swinging  
in-swinging door  
double action door  
GIANNI INDUSTRIES, INC.  
No. 13, Zhong Sing Road, Tu-Cheng Industrial Zone,  
Tu-Cheng City, Taipei, Taiwan 23678  
The products are manufactured under an ISO  
9001  
&
QC 080000 Certified Quality  
Management Program environment back its  
product quality, performance and commitment  
to customer satisfaction.  
Tel: 886-2 2267 7986 / Fax: 886-2 2267 9876  
Website: gianni.tw  
Copyright 2008 Gianni industries, inc. All rights reserved.  
DM-CA-EB-262 Ver. E Published on 2008.10.20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Blower PB 755S H User Manual
Escort Radar Detector ZR3 User Manual
Fellowes Chipper P 35C User Manual
Fisher Paykel Washer GWLO8 User Manual
Fostex Microphone SF20C User Manual
Furman Sound Power Supply IT 20 II User Manual
Furuno SONAR FCV 582L User Manual
GE Monogram Oven ZET1RM User Manual
Genesis Advanced Technologies Speaker System G61 User Manual
GE Universal Remote 24962 User Manual