Models:
005411-0, 005413-0, 005415-0, 005751-0,
005752-0, 005753-0, 005855-0, 005856-0,
005857-0
Owner's Manual
Air-cooled Recreational
Vehicle Generators
RV 45, 55 and 65
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
The operator (driver) is responsible for proper and safe use of the
vehicle and its equipment, and the safety of all vehicle occupants.
We strongly recommend that the operator read this manual and
thoroughly understand all instructions before using this equipment.
We also strongly recommend instructing other occupants in the
vehicle to properly start and operate the generator. This prepares
them if they need to operate the equipment in an emergency.
INTRODUCTION
READ THIS MANUAL THOROUGHLY
If any portion of this manual is not understood, contact the near-
est Authorized Service Dealer for starting, operating and servicing
procedures.
Throughout this publication, and on tags and decals affixed to the
generator, DANGER, WARNING, CAUTION and NOTE blocks are
used to alert personnel to special instructions about a particular
operation that may be hazardous if performed incorrectly or care-
lessly. Observe them carefully. Their definitions are as follows:
CONTENTS
This manual contains pertinent owner’s information, including
warranty, electrical diagrams, exploded views and lists of repair
parts. In addition, the latter portion of this manual contains infor-
mation necessary for the proper installation of these generators.
After this heading, read instructions that, if not
strictly complied with, will result in personal
injury, including death, and property damage.
OPERATION AND MAINTENANCE
It is the operator's responsibility to perform all safety checks, to
make sure that all maintenance for safe operation is performed
promptly, and to have the equipment checked periodically by
an Authorized Service Dealer. Normal maintenance service and
replacement of parts are the responsibility of the owner/operator
and, as such, are not considered defects in materials or workman-
ship within the terms of the warranty. Individual operating habits
and usage contribute to the need for maintenance service.
After this heading, read instructions that, if not
strictly complied with, may result in personal
injury or property damage.
After this heading, read instructions that, if not
strictly complied with, could result in damage
to equipment and/or property.
Proper maintenance and care of the generator ensures a minimum
number of problems and keep operating expenses at a minimum.
See an Authorized Service Dealer for service aids and acces-
sories.
NOTE:
After this heading, read explanatory statements that require
special emphasis.
HOW TO OBTAIN SERVICE
When the generator requires servicing or repairs, simply contact
an Authorized Service Dealer for assistance. Service technicians
are factory-trained and are capable of handling all service needs.
These safety warnings cannot eliminate the hazards that they
indicate. Common sense and strict compliance with the special
instructions while performing the service are essential to prevent-
ing accidents.
When contacting an Authorized Service Dealer about parts and
service, always supply the complete model number and serial
number of the unit as given on its data decal, which is located on
the generator.
Four commonly used safety symbols accompany the Danger,
Warning and Caution blocks. The type of information each indi-
cates follows:
nThis symbol points out important safety
information that, if not followed, could
endanger personal safety and/or property of
others.
Model No. _________________ Serial No.______________
This symbol points out potential explosion
hazard.
Authorized SERVICE
DEALER LOCATION
To locate the nearest AUTHORIZED SERVICE
DEALER, please call this number:
This symbol points out potential fire hazard.
This symbol points out potential electrical
shock hazard.
1-800-333-1322
ONLY DEALER LOCATION INFORMATION
CAN BE OBTAINED AT THIS NUMBER.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Rules
nSAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be
copied and posted in potential hazard areas of the recreational vehicle. Safety should be stressed to
all operators and potential operators of this equipment.
Study these SAFETY RULES carefully before installing, operating
or servicing this equipment. Become familiar with this manual and
with the unit. The generator can operate safely, efficiently and reli-
ably only if it is properly installed, operated and maintained. Many
accidents are caused by failing to follow simple and fundamental
rules or precautions.
GENERAL HAZARDS
• For safety reasons, the manufacturer recommends that the
installation, initial start-up and maintenance of this equipment
is carried out by an Authorized Service Dealer.
• The generator engine releases DEADLY carbon monoxide gas
through its exhaust system. This dangerous gas, if breathed
in sufficient concentrations, can cause unconsciousness or
even death. Never operate the generator set with the vehicle
inside any garage or other enclosed area. Shut down the
generator and do not operate it until it has been inspected
and repaired.
The manufacturer cannot anticipate every possible circumstance
that might involve a hazard. The warnings in this manual, and on
tags and decals affixed to the unit, are, therefore, not all-inclusive.
If using a procedure, work method or operating technique the
manufacturer does not specifically recommend, ensure that it is
safe for others. Also make sure the procedure, work method or
operating technique that chosen does not render the generator
unsafe.
• DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM
IS LEAKING OR HAS BEEN DAMAGED.
• SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a)
inability to think coherently, (b) nausea, (c) vomiting,
(d) twitching muscles, (e) throbbing temples, (f) dizzi-
ness, (g) headaches, (h) weakness, and (i) sleepiness. IF
EXPERIENCING ANY OF THESE SYMPTOMS, MOVE INTO
FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET
MEDICAL HELP.
• Never sleep in the vehicle while the genset is running unless
the vehicle has a working carbon monoxide detector. The
exhaust system must be installed in accordance with the
genset installation manual. Make sure there is ample fresh
air when operating the genset in a confined area.
• Keep hands, feet, clothing, etc., away from drive belts, fans,
and other moving or hot parts. Never remove any drive belt or
fan guard while the unit is operating.
• Adequate, unobstructed flow of cooling and ventilating air is
critical to correct generator operation and is required to expel
toxic fumes and fuel vapors from the generator compartment.
Without sufficient cooling airflow, the engine/generator quickly
overheats, which causes serious damage to the generator. Do
not alter the installation or permit even partial blockage of ven-
tilation provisions, as this can seriously affect safe operation of
the generator.
nDespite the safe design of this generator,
operating this equipment imprudently,
neglecting its maintenance or being careless
can cause
possible injury or death. Permit only respon-
sible and capable persons to operate or
maintain this equipment.
Potentially lethal voltages are generated by
these machines. Ensure all steps are taken to
render the machine safe before attempting to
work on the generator.
nParts of the generator are rotating and/or hot
during operation. Exercise care near running
generators.
• When working on this equipment, remain alert at all times.
Never work on the equipment when physically or mentally
fatigued.
• Inspect the generator regularly, and contact the nearest
Authorized Service Dealer immediately for parts needing repair
or replacement.
CALIFORNIA PROPOSITION 65 WARNING
Engine exhaust and some of its constituents are known
to the State of California to cause cancer, birth defects
and other reproductive harm.
• Before performing any maintenance on the generator, discon-
nect its battery cables to prevent accidental start up. Disconnect
the cable from the battery post indicated by a NEGATIVE, NEG
or (–) first. Reconnect that cable last.
• Never use the generator or any of its parts as a step. Stepping
on the unit can stress and break parts, and may result in dan-
gerous operating conditions from leaking exhaust gases, fuel
leakage, oil leakage, etc.
CALIFORNIA PROPOSITION 65 WARNING
This product contains or emits chemicals known to the
State of California to cause cancer, birth defects and
other reproductive harm.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Rules
ELECTRICAL HAZARDS
FIRE HAZARDS
• The generator covered by this manual produces dangerous
electrical voltages and can cause fatal electrical shock. Avoid
contact with bare wires, terminals, connections, etc., while the
unit is running. Ensure all appropriate covers, guards and bar-
riers are in place before operating the generator. If work must
be done around an operating unit, stand on an insulated, dry
surface to reduce shock hazard.
• Do not handle any kind of electrical device while stand-
ing in water, while barefoot, or while hands or feet are wet.
DANGEROUS ELECTRICAL SHOCK MAY RESULT.
• During installation onto the vehicle, have the generator prop-
erly grounded (bonded) either by solid mounting to the vehicle
frame or chassis, or by means of an approved bonding conduc-
tor. DO NOT disconnect the bonding conductor, if so equipped.
DO NOT reconnect the bonding conductor to any generator part
that might be removed or disassembled during routine mainte-
nance. If the grounding conductor must be replaced, use only a
flexible conductor that is of No. 8 American Wire Gauge (AWG)
copper wire minimum.
• For fire safety, the generator must be installed and maintained
properly. Installation always must comply with applicable
codes, standards, laws and regulations. Adhere strictly to local,
state and national electrical and building codes. Comply with
regulations the Occupational Safety and Health Administration
(OSHA) has established. Also, ensure that the generator is
installed in accordance with the manufacturer’s instructions
and recommendations. Following proper installation, do noth-
ing that might alter a safe installation and render the unit in
noncompliance with the aforementioned codes, standards,
laws and regulations.
• Keep a fire extinguisher in the vehicle at all times. Extinguishers
rated “ABC” by the National Fire Protection Association are
appropriate for use on the recreational vehicle generator elec-
trical system. Keep the extinguisher properly charged and be
familiar with its use. If there are any questions pertaining to fire
extinguishers, consult the local fire department.
• In case of accident caused by electric shock, immediately
shut down the source of electrical power. If this is not pos-
sible, attempt to free the victim from the live conductor. AVOID
DIRECT CONTACT WITH THE VICTIM. Use a nonconducting
implement, such as a rope or board, to free the victim from the
live conductor. If the victim is unconscious, apply first aid and
get immediate medical help.
• Never wear jewelry when working on this equipment. Jewelry
can conduct electricity resulting in electric shock, or may get
caught in moving components causing injury.
EXPLOSION HAZARDS
• Do not smoke around the generator. Wipe up any fuel or oil
spills immediately. Ensure that no combustible materials are left
in the generator compartment, or on or near the generator, as
FIRE or EXPLOSION may result. Keep the area surrounding the
generator clean and free from debris.
• Gasoline is extremely FLAMMABLE and its vapors are
EXPLOSIVE. Do not permit smoking, open flame, sparks or any
source of heat in the vicinity while handling gasoline. Comply
with all laws governing the storage and handling of gasoline.
• This generator may use liquid propane (LP) gas as a fuel. LP
gas is highly EXPLOSIVE. The gas is heavier than air and tends
to settle in low areas where even the slightest spark can ignite
the gas and cause an explosion.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
1.1 GENERATOR IDENTIFICATION
Please record the following information from the generator DATA DECAL or information decal.
1. Model Number ____________________
3. kW Rating _________________________
5. Phase _____________________________
2. Serial Number _________________
4. Rated Voltage _________________
6. Hertz __________________________
18
8
2
15
13
10, 17 3 4 5
1
12 11
14
16
6
7
10
9, 17
REFERENCE NUMBER IDENTIFICATION
1. Generator Air Intake
2. Data Plate
3. Engine Start/Stop Switch
4. 7.5 amp Fuse
10. Fuel Pump
11. Oil Filter
12. Oil Drain Plug
13. Oil Dipstick and Filler Tube
14. Air Filter (Behind access panel.)
15. Spark Plugs
16. Exhaust Outlet
17. Fuel Filter
18. Evaporative Port
5. Circuit Breaker
6. Optional Remote Panel Receptacle
7. Generator AC Output Leads
8. Starter Contactor
9. Fuel Inlet
4
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
1.2 GENERATOR APPLICABILITY
These generators have been designed and manufactured for sup-
plying electrical power for recreational vehicles. DO NOT modify
the generator or use it for any application other than for what it
was designed. If there are any questions pertaining to its applica-
tion, write or call the factory. Do not use the unit until advised by
competent authority.
1.3 INSTALLATION
This Owner’s Manual has been prepared under the assumption
that a competent, qualified technician installed the generator into
a recreational vehicle. We also assume the installer complied
with all applicable codes, standards and regulations pertaining to
installation.
An INSTALLATION MANUAL was shipped with the generator. That
Manual contains manufacturer’s instructions and recommenda-
tions for installing the unit into an industrial vehicle. After installa-
tion, installers should forward the Installation Manual to Owners/
Operators for their information.
For fire safety, the generator must have been
properly installed in compliance with ANSI
119.2-1975/NFPA 501C-1974, “Standard for
Recreational Vehicles, Part III – Installation
of Electrical Systems.” The generator also
must have been installed in strict compliance
with the manufacturer’s detailed installation
instructions. After installation, do nothing
that might render the unit in noncompliance
with such codes, standards and instructions.
Owners/Operators have the responsibility to make sure that noth-
ing is done that might render the installation unsafe or in non-
compliance with applicable codes, standards and instructions.
1.4 SAFETY
Before using the generator set, carefully read GENERAL SAFETY
RULES inside the cover. Comply with these RULES to prevent
accidents and damage to equipment and/or property. The manu-
facturer suggests copying and posting the GENERAL SAFETY
RULES to potential operators of this equipment.
Use the generator set to supply electrical power for operating one
of the following electrical loads:
• RV 45 G: 120 and/or 240 volts, single phase, 60 Hz electrical
loads. These loads can require up to 4500 watts (4.5 kW) of
total power, but cannot exceed 37.5 AC amperes of current at
120 volts (breaker is limited to 30 Amps).
• RV 55 G: 120 and/or 240 volts, single phase, 60 Hz electrical
loads. These loads can require up to 5500 watts (5.5 kW) of
total power, but cannot exceed 45.8 AC amperes of current at
120 volts or exceed 22.9 AC amperes at 240 volts.
• RV 65 G: 120 and/or 240 volts, single phase, 60 Hz electrical
loads. These loads can require up to 6500 watts (6.5 kW) of
total power, but cannot exceed 54.1 AC amperes of current at
120 volts or exceed 27 AC amperes at 240 volts.
1.5 GENERATOR AC CONNECTION
SYSTEM
These air-cooled generator sets are equipped with dual stator
AC power windings. These two stator windings supply electrical
power to customer electrical loads by means of a dual 2-wire
connection system.
Generators may be installed to provide the following outputs:
1. 120 VAC loads only — two loads, each with a maximum
total wattage requirement equal to half of the generator’s
rated power output (in watts), and 120V across the generator
output terminals. Figure 1.1 shows the generator lead wire
connections for 120VAC ONLY.
Do not overload the generator. Some instal-
lations may require that electrical loads be
nꢀ
Figure 1.1 – Connection for 120 Volts Only
alternated to avoid overloading. Applying
excessively high electrical loads may dam-
age the generator and may shorten its
life. Add up the rated watts of all electrical
lighting, appliance, tool and motor loads
the generator will power at one time. This
total should not be greater than the watt-
age capacity of the generator. If an electri-
cal device nameplate gives only volts and
amps, multiply volts times amps to obtain
watts (volts x amps = watts). Some elec-
tric motors require more watts of power (or
amps of current) for starting than for con-
tinuous operation.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
2. 120/240 VAC loads — one load with a maximum total watt-
age requirement equal to the generator’s rated power output,
and 240V across the generator output terminals; or two sepa-
rate loads, each with a maximum total wattage requirement
equal to half of the generator’s rated power output (in watts),
and 120V across the generator output terminals. Figure 1.2,
shows the generator lead wire connections for 120/240 VAC
loads. Also refer to the "Line Breakers" section for circuit
breaker ratings.
NOTE
Some installations using a “shared” fuel tank may have a gen-
erator fuel pickup tube that is shorter than the vehicle engine’s
pickup tube. Such an arrangement causes the generator engine
to “run out of gas” while adequate fuel for the vehicle remains
in the tank.
To reduce lead and carbon deposits use high quality UNLEADED
gasoline with the generator. Leaded REGULAR grade gasoline is an
acceptable substitute.
This procedure should be done by an Authorized Service Dealer or
other qualified installer.
NOTE:
Using unleaded gasoline contributes to longer engine valve life by
reducing lead and carbon deposits.
Figure 1.2 - Connection for 120/240 Volts
T1
RED
CB1
nThe manufacturer does not recommend
using any gasoline containing alcohol (such
as “gasohol”). If using any gasoline contain-
ing alcohol, it must not contain more than
10 percent ethanol (Do not use E85), and it
must be removed from the generator during
storage. Do NOT use any gasoline contain-
ing methanol. If using gasoline with alcohol,
inspect more frequently for fuel leaks and
other abnormalities.
T2
WHITE
1.6.2 ENGINE OIL REQUIREMENTS
All oil should meet minimum American Petroleum Institute (API)
Service Class SJ, SL or better. Use no special additives. Select the
oil's viscosity grade according to the expected operating tempera-
ture (also see chart).
CB2
T3
BLACK
GROUNDED NEUTRAL
STATOR POWER
WINDINGS
• SAE 30 Î Above 32° F
• 10W-30 Î Between 40° F and -10° F
• Synthetic 5W-30 Î 10° F and below
1.6 SPECIFICATIONS
1.6.1 FUEL REQUIREMENTS (GASOLINE)
SAE 30
This generator is equipped with a gasoline fuel system as standard
equipment. Specific installations may provide either a separate fuel
tank for the generator, or the generator may “share” the vehicle
engine’s fuel tank.
10W-30
Syntthetiic 5W-30
1.6.1.1 Fuel Consumption (gph)
Model
RV45G
RV55G
RV65G
10% Load
50% Load
100% Load
.33
.35
.37
.45
.55
.65
.73
.89
.97
Crankcase and oil filter capacity is approximately 1.4 L or 1.5 U.S.
quarts. DO NOT use special additives. See sections "Checking the
Engine Oil Level" and "Changing the Engine Oil and/or Oil Filter" for
oil level check and filling procedures.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
1.6.3 GENERATOR SPECIFICATIONS
SERIES
RV45G
3600
RV55G
3600
RV65G
3600
Rotor RPM
Rotor Poles
2
2
2
Engine RPM
2571
2571
2571
Rated Max. Continuous AC Output Watts*
4500
5500
6500
Voltage*
120
120
120
Rated Max. Continuous Current Amps (240V)
37.5 (18.7)
1
45.8 (22.9)
1
54.1 (27)
1
Phase
Frequency
Weight
Length
Width
60 Hertz
278 lbs.
33.7 in.
21.5 in.
16.8 in.
60 Hertz
285 lbs.
33.7 in.
21.5 in.
16.8 in.
60 Hertz
293 lbs.
33.7 in.
21.5 in.
16.8 in.
Height
*
All units are re-connectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambient temperature, altitude, engine condition, etc.. Maximum power
decreases about 3.5% for each 1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60° F) ambient temperature.
• Fuel Metering System
~ Carburetor assembly
~ Fuel pump and lines
• Air Induction System
~ Intake pipe / manifold
~ Air cleaner
• Ignition System
~ Spark plug
~ Ignition module
• Catalytic Converter (if equipped)
1.6.4 ENGINE SPECIFICATIONS
Type of Engine........................................................................GT-530
Cooling Method................................................................ Air-cooled
Rated Horsepower ...................................................18 at 3600 rpm
Displacement........................................................................... 530cc
Compression Ratio................................................................8.5 to 1
Cylinder Block.................................. Aluminum w/Cast Iron Sleeve
Type of Governor.......................................Electronic, Fixed Speed
Engine Governor Speed................................................... 2571 rpm
Air Cleaner................................................................. Paper Element
Starter .................................................................. 12-volt DC Electric
Ignition System ............................ Solid-state w/Flywheel Magneto
Recommended Spark Plug
The Emissions Compliance Period referred to on the Emissions
Compliance Label indicates the number of operating hours for
which the engine has been shown to meet Federal and California
emission requirements. See the table below to determine the com-
pliance period for this generator. The displacement of the engine is
listed on the Emissions Compliance Label.
NGK....................................................................................BPR6HS
Spark Plug Gap ............................................. 0.030 inch (0.76 mm)
Recommended Min. Battery.................. 400 Cold Cranking Amps
Class II Emission Certified
Displacement
Category
Compliance Period
500 Hours
1.7 EXHAUST EMISSIONS
A
B
C
A
B
C
INFORMATION (GASOLINE)
> 66 cc - < 225 cc
250 Hours
The Environmental Protection Agency (EPA) and the California Air
Resource Board (CARB) require that this generator comply with
exhaust emission standards. The generator is certified to meet all
applicable exhaust emission levels. This generator is certified for
use as a mobile engine. It is important that you follow the mainte-
nance specifications listed in this manual to ensure that the engine
complies with emission standards for the duration of its life. This
engine is certified to operate on gasoline. The emission control
system on the generator consists of the following:
125 HOurs
1000 Hours
500 Hours
≥ 225 cc
250 Hours
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Figure 2.1 – Typical Control Panel
1.8 EVAPORATIVE EMISSIONS
INFORMATION
This generator is subject to evaporative emission standards which
have been implemented by the California Air Resource Board
(CARB) and the Environmental Protection Agency (EPA). If this
generator is offered for sale in the state of California, it must be
covered by a CARB evaporative Executive Order. If this generator
is offered for sale to the final consumer in any other state, certified
low-permeation fuel line must be used to supply fuel to the genera-
tor as required by EPA.
Anyone who installs or configures a fuel system to supply this
generator with gasoline is required to comply with all applicable
evaporative emission regulations. If this generator is configured
such that it shares the primary fuel system of a vehicle in which it
is installed, reduced certification requirements may apply. See the
ca.gov/msprog/macs/mac0505/mac0505.pdf for further details. If
this generator is installed such that it uses a dedicated fuel system,
detailed evaporative emission requirements apply; contact a repu-
table fuel system manufacturer to purchase a complete fuel sys-
tem certified for use with this generator, or consult the California
Code of Regulations if you wish to obtain certification on your
own. See the installation instructions in this manual for connecting
fuel system vapor lines to the engine.
The switch center position is the RUN position.
To stop a running engine, press momentarily the bottom half of the
switch to kill the ignition.
2.1.2 7.5 AMP FUSE
The fuse protects the engine’s DC control circuit against electrical
overload. If the fuse element has melted open due to overloading,
the engine cannot be cranked. If the fuse must be replaced, use
only an identical 7.5 amp replacement fuse.
This generator is not legal for sale in the state of California unless
all CARB evaporative emission requirements are adhered to, and
is not legal for sale in any other state unless certified low-per-
meation fuel line is used to supply the generator with gasoline.
Contact the California Air Resource Board or the Environmental
protection agency for further information. CARB regulations can
be found in 13 CCR §§2750 – 2773; EPA regulations can be
found in 40 CFR Part 90.
2.1.3 LINE BREAKERS
Protects generator’s AC output circuit against overload, i.e., pre-
vents unit from exceeding wattage/amperage capacity. The circuit
breaker ratings are as follows:
2.1 GENERATOR CONTROL PANEL
The following features are mounted on the generator control panel
(Figure 2.1):
Model
RV45
RV55
RV65
Cir. Breaker 1
Cir. Breaker 2
240 Volt
N/A
30A
20A
30A
N/A
30A
30A
25A 2P
30A 2P
2.1.1 START/STOP SWITCH
This generator is started with a "One Touch" starting sequence.
Push up on the top half of the momentary switch. Hold for one
(1) second and release. Note flashing indicator light on the switch.
Fuel pump engages automatically for a three (3) to five (5) second
delay before starter motor cranks the engine for 16 seconds or
until the engine starts. If the engine does not start, the starter
will cool for seven (7) seconds and crank the engine again for 16
seconds. If the engine does not start, the starter will cool for seven
(7) seconds before cranking for seven (7) seconds to a maximum
cycle total of 90 seconds. Once started, the light on the switch
stays on continuously. If the generator does not start at the end
of the start sequence, a fault code will flash on the switch (see
Diagnostics).
NOTE:
If this generator has been reconnected for dual voltage AC out-
put (120/240 volts), install line breakers having an amperage
rating equal to that stated in the preceding chart. The replace-
ment line breakers consist of two separate breakers with a
connecting piece between the breaker handles (so that both
breakers will operate at the same time). If the unit is recon-
nected for dual voltage, it is no longer RVIA listed.
The switch center position is the RUN position.
To stop a running engine, press momentarily the bottom half of the
switch to kill the ignition.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
2.1.4 DIAGNOSTICS
2.3.2 PRECHOKE
If the generator shuts down due to a fault, the indicator will flash a
code to identify the problem.
The choke system also has a temperature-sensitive metal strip that
adjusts choke valve angle according to ambient temperatures (i.e.,
in cold ambient temperatures, choke valve closes more). Once the
engine starts, an element heats the temperature-sensitive strip to
a normal operating condition, opening the choke valve. This may
take about three minutes in cooler weather (Gasoline only.).
• 2 Flashes = Low Battery (Voltage falls below 11.0 VDC for one
minute)
NOTE:
Alarm will clear automatically if voltage rises over 11.0 VDC.
Battery voltage is not monitored during crank cycle.
2.4 BEFORE STARTING THE
• 3 Flashes = Overcrank (Unit does not start through entire start
ENGINE
cycle)
NOTE:
• 4 Flashes = Overspeed (Alternator spins at 4200 rpm/72 Hz
or greater)
Instructions and information in this manual assume the genera-
tor has been properly installed, connected, serviced, tested and
adjusted by a qualified installation technician or installation
contractor.
• 5 Flashes = Low Oil Pressure (Drops below the 5 psi threshold
of the switch)
NOTE:
There is a five second delay of the alarm when the engine is
first started up.
2.4.1 INSTALLATION
Generator installation must have been properly completed so it
complies with all applicable codes, standards and regulations
and with the manufacturer's recommendations. (See Part II -
Installation Instructions.)
• 6 Flashes = High Oil Temperature (Unit shuts down when tem-
perature switch limit is reached)
NOTE:
2.4.2 ENGINE LUBRICATION
As the unit cools down it will attempt to restart automatically
when the temperature switch opens again.
Have the engine crankcase properly serviced with the recommend-
ed oil before starting. Refer to sections "Engine Specifications",
"Checking the Engine Oil Level" and "Changing the Engine Oil and/
or Oil Filter" for oil servicing procedures and recommendations.
• 7 Flashes = Underspeed (Alternator spins less than 3240
rpm/54 Hz for three (3) seconds)
NOTE:
After a fault is indicated, press stop momentarily to clear the
alarm once the problem is fixed.
nAny attempt to crank or start the engine
before it has been properly serviced it with
the recommended oil may result in an engine
failure.
2.2 OPTIONAL REMOTE
START/STOP PANEL
A remote mounted Start/Stop Panel is available that allows start-
ing and stopping the generator engine conveniently from inside the
vehicle. The remote panel includes a Start/Stop switch, hourmeter,
generator run lamp, and a wire harness.
2.4.3 FUEL SUPPLY
The engine must have an adequate supply of proper fuel to oper-
ate. Before starting it, check that sufficient fuel is available.
NOTE:
Depending on the installation, the generator may have either a
separate fuel tank, or it may “share” the vehicle engine’s fuel
tank.
2.3 AUTOMATIC CHOKE
This engine is equipped with an automatic choke that consists of
two main components: a choke solenoid and prechoke (Gasoline
only.).
2.4.4 COOLING AND VENTILATING AIR
2.3.1 CHOKE SOLENOID
Air inlet and outlet openings in the generator compartment must
be open and unobstructed for continued proper operation. Without
sufficient cooling and ventilating airflow, the engine/generator
quickly overheats, which causes it to shut down and may damage
the generator.
During engine cranking (Start/Stop switch at START), a solid-state
choke module signals the choke solenoid to activate and cycle
(choke on/choke off) until the engine starts. The choke solenoid
thus opens and closes the carburetor choke valve only when
the engine is cranking. When the engine starts, the choke stops
cycling (Gasoline only.).
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
NOTE:
2.4.5 ENGINE EXHAUST GAS
If starting from the generator control panel, turn OFF loads
by setting the generator’s main circuit breaker to the OFF (or
open) position. If starting from a remote panel, turn OFF loads
using the means provided in the vehicle (such as a main circuit
breaker). Electrical load circuits should be turned ON after the
generator has started, stabilized and warmed up.
Before starting the generator engine, be sure there is no way for
exhaust gases to enter the vehicle interior and endanger people or
animals. Close windows, doors and other openings in the vehicle
that, if open, might permit exhaust gases to enter the vehicle.
2. To crank and start the engine, push up on the Start/Stop
switch momentarily and release. There is a delay as the fuel
pump primes and the generator automatically begins the start
sequence (Note the flashing light on the switch.).
3. Let the engine run at no-load for a few minutes to stabilize and
warm up.
The generator engine releases DEADLY
n
carbon monoxide gas through its exhaust
system. This dangerous gas, if breathed in
sufficient concentrations, can cause uncon-
sciousness or even death. Never operate
the generator set with the vehicle inside
any garage or other enclosed area. DO NOT
OPERATE THE GENERATOR IF THE EXHAUST
SYSTEM IS LEAKING OR HAS BEEN
4. Turn ON electrical loads using the means provided (such as a
main circuit breaker or transfer switch).
DAMAGED. Shut down the generator and
do not operate it until it has been inspected
and repaired. SYMPTOMS OF CARBON
MONOXIDE POISONING ARE (a) inability to
think coherently, (b) nausea, (c) vomiting, (d)
twitching muscles, (e) throbbing temples, (f)
dizziness, (g) headaches, (h) weakness, and
(i) sleepiness. IF EXPERIENCING ANY OF
THESE SYMPTOMS, MOVE INTO FRESH AIR
IMMEDIATELY. IF SYMPTOMS PERSIST, GET
MEDICAL HELP.
2.6 STOPPING THE GENERATOR
1. Turn OFF all electrical loads using the means provided (such
as a main circuit breaker or transfer switch).
2. Let generator run at no-load for a few minutes, to stabilize
internal engine generator temperatures.
3. Place the Start/Stop switch in its STOP position. The engine
will come to a complete stop.
2.7 APPLYING LOADS TO
GENERATOR
When applying electrical loads to the generator, observe these
guidelines:
nNever sleep in the vehicle while the genset
is running unless the vehicle has a working
• Before applying electrical loads, let the generator stabilize and
warm up for a minute or two.
• DO NOT overload the generator.
carbon monoxide detector. The exhaust sys-
tem must be installed in accordance with the
genset installation manual. Make sure there
is ample fresh air when operating the genset
in a confined area.
2.7.1 LETTING THE ENGINE STABILIZE
The generator supplies correct rated voltage only at the proper
governed speed. Some electrical appliances may be extremely
sensitive to voltage. Incorrect voltages can damage such appli-
ances.
2.5 STARTING THE GENERATOR
NOTE:
If electrical loads are applied at reduced operating speeds, such
loads imposed on the engine when sufficient power is not available
may shorten engine life. Never turn ON electrical loads until after
the generator engine has started and stabilized at no-load.
Read the vehicle manufacturer’s instructions. The owner/
operator should become familiar with the vehicle in which this
generator is installed. Differences exist between vehicles. For
example, some vehicles may use a transfer switch to isolate
dockside power from the generator, while other vehicles may
use an isolating receptacle. Some vehicles may be equipped
with a DC converter which allows the generator to power certain
DC lighting and other DC loads.
2.7.2 DO NOT OVERLOAD THE GENERATOR
Read the rated wattage/amperage capacity of the generator on the
generator data label (See the "Generator Identification" section.).
To crank and start the generator engine, proceed as follows:
Applying electrical loads in excess of the unit’s rated capacity will
cause the engine/generator to automatically shut down.
1. Turn OFF electrical loads using the means provided in the
vehicle (such as a main line circuit breaker or transfer
switch).
To avoid overloading, add up the wattage of all connected electrical
lighting, appliance, tool and motor loads. This total should not be
greater than the generator’s rated wattage capacity.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
• Most lighting, appliance, tool and motor loads indicate their
required watts on their nameplate or data plate. For light bulbs,
simply note the wattage rating of the bulb.
2.8.3 FIELD BOOST
The Controller Circuit Board houses a field boost diode and resistor
that are not part of the automatic choke circuit. These two compo-
nents are part of a “field boost” circuit (Figure 2.3). During engine
cranking only, a positive DC (battery) voltage is delivered through
a diode, resistor, brushes, slip rings, and the generator rotor.
Application of this voltage to the rotor “flashes the field” whenever
it is started. Flashing of the field each time the generator starts
makes sure that a sufficiently strong magnetic field is available to
produce “pickup” voltage in the stator windings.
• If a load does not show its rated wattage, multiply that load’s
rated VOLTS times AMPS to obtain WATTS.
• Induction type motors (such as those that run the vehicle’s
furnace fan, refrigerator, air conditioner, etc.) need about 2-1/2
times more watts of power for starting than for running (for a
few seconds during motor starting). Be sure to allow for this
when connecting electrical loads to the generator. First, figure
the watts needed to start electric motors in the system. To that
figure, add the running wattages of other items that will be oper-
ated by the generator.
Figure 2.3 – Field Boost Circuit
• Do not apply heavy electrical loads for the first two or three
hours of operation.
2.8 PROTECTION SYSTEMS
2.8.1 LOW OIL PRESSURE SWITCH
This switch (Figure 2.2) has normally closed (N.C.) contacts that
are held open by engine oil pressure during cranking and operat-
ing. Should oil pressure drop below a preset level, switch contacts
close, and the engine automatically shuts down. The unit should
not be restarted until oil is added.
2.8.2 HIGH TEMPERATURE SWITCH
This switch (Figure 2.2), which has normally open (N.O.) contacts,
is mounted near the oil filter. The contacts close if the temperature
should exceed approximately 270º F (132º C) for gasoline mod-
els.
2.8.4 OVERVOLTAGE PROTECTION
A solid-state voltage regulator (Figure 2.4) controls the generator’s
AC output voltage. This regulator supplies an excitation current to
the rotor. By regulating the rotor’s excitation current, the strength
of its magnetic field is regulated and, in turn, the voltage delivered
to connected electrical loads is controlled. When the AC frequency
is 60 Hertz, voltage is regulated at 125 to 120 volts.
Figure 2.2 – Low Oil Pressure and
High Temperature Switches
Figure 2.4 – Solid State Voltage Regulator
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
2.8.5 OPERATION IN HIGH GRASS OR BRUSH
3.2 CHANGING THE ENGINE OIL
AND/OR OIL FILTER
Never operate the generator while the vehicle
is parked over high grass, weeds, brush,
nHot oil may cause burns. Allow engine to
cool before draining oil. Avoid prolonged
leaves or any other combustible substance.
Such materials can ignite and burn from the
heat of the exhaust system. The generator
exhaust system becomes extremely hot dur-
ing operation and remains hot for a long time
after it has shut down.
or repeated skin exposure with used oil.
Thoroughly wash exposed areas with soap.
Oil Change Intervals – see Section “RV Generator Service
Interval”.
To change the oil and oil filter, proceed as follows:
3.1 CHECKING THE ENGINE OIL
1. Run the engine until it is thoroughly warmed up (at least five
minutes) then shut off the engine.
2. With the engine still warm from running, remove the round
access grommet from underneath the front of the generator.
Place a suitable container underneath to catch all the drain
oil.
LEVEL
For oil capacities and requirements, see the “Engine Oil
Requirements” section. Check the engine crankcase oil level at
least every eight hours of operation, or before it is used. To check
the engine oil level, proceed as follows (see Figure 3.1):
1. Be sure the generator is as level as possible.
2. Remove the dipstick and wipe it dry with a clean, lint-free
cloth.
3. Install and tighten the dipstick cap; then, remove it again. The
oil level should be at the dipstick “Full” mark.
4. If necessary, remove the oil fill cap on the rocker cover and
slowly add oil until it reaches the dipstick “Full” mark. DO NOT
FILL ABOVE THE “FULL” MARK.
3. Use the 0G4818 tool (supplied with the generator) to turn the
old filter counter-clockwise and remove. Let oil drain into the
container located directly below.
4. Locate the oil drain hose inside and pull the yellow drain plug
out of the access hole (Figure 3.1).
5. Turn the yellow cap counter-clockwise to remove and finish
draining the old oil.
6. After the oil has been drained, replace the oil drain plug by
tightening it clockwise and return.
7. Clean off the oil filter bracket and any old oil that may have
spilled while draining.
nNever operate the engine with the oil level
below the “Add” mark on the dipstick. Doing
8. Apply a light coating of clean engine oil the gasket of the new
oil filter (Figure 3.2).
this could damage the engine.
9. Screw the new oil filter on by hand until its gasket lightly con-
tacts the oil filter adapter. Then, tighten the filter an additional
¾ to one turn. Replace and secure the round access grom-
met.
5. Install and tighten the oil fill cap and the dipstick before oper-
ating the engine.
Figure 3.1 — Oil Dipstick/Fill Tube and
Location of Oil Drain Plug
Figure 3.2 — Engine Oil Filter
Engine
Oil Filter
Oil Fill
Oil Drain Hose
Oil Dipstick
Twist Counter-clockwise to Loosen
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
10. Remove the dipstick, valve cover plug and add new oil (see
3.4 CHECKING THE ENGINE
“Engine Oil Requirements”) to engine. DO NOT FILL ABOVE
SPARK PLUG
THE “FULL” MARK.
Reset the spark plug gap or replace the spark plugs as necessary.
See the Service Schedule section for maintenance requirements.
11. Install and tighten plug and dipstick before starting the
engine.
12. Start engine and check for leaks.
1. Clean the area around the base of the spark plugs to keep dirt
and debris out of the engine.
NOTE:
2. Remove the spark plugs and check the condition. Replace the
spark plugs if worn or if reuse is questionable. See the Service
Schedule section for recommended interval. Clean by scrap-
ing or washing using a wire brush and commercial solvent.
Do not blast the spark plugs to clean.
3. Check the spark plug gap using a wire feeler gauge. Adjust the
gap to 0.76mm (0.030 inch) by carefully bending the ground
electrode if necessary (Figure 3.4).
Check the oil level and fill to the “FULL” mark after checking for
leaks. The filter will retain some oil.
3.3 MAINTAINING THE ENGINE
AIR CLEANER
Replace the paper air filter element after every 200 hours of opera-
tion. (Perform more often when operating in dusty conditions)
1. At the Air Cleaner Cover, turn the yellow plastic knob ¼ turn
counter-clockwise.
Figure 3.4 – Setting the Spark Plug Gap
2. Pull the top of the Cover out as it hinges on the bottom of the
Air Cleaner Base.
3. Separate the Cover by lifting up and out from the Base.
4. Pull the old filter out and discard safely.
5. Install the new filter in place on the Air Cleaner Base (Figure
3.3).
6. Interlock the Air Cleaner Cover to hinge with the Air Cleaner
Base.
7. Align the Cover and gently push the top closed.
8. Engage the yellow plastic knob and turn ¼ turn clockwise to
secure.
nSparking can occur if the wire terminal does
not fit firmly on the spark plug terminal end.
If necessary, re-form the wire terminal to
obtain a tight fit.
Figure 3.3 – Engine Air Cleaner
Air Cleaner Base
3.5 FUEL FILTER (GASOLINE ONLY)
Remove and replace the fuel filter (Figure 3.5) every 400 hours of
operation.
Air Cleaner
Figure 3.5 – Fuel Filter
Knob
FUEL FILTER
TO FUEL PUMP
Air Cleaner Cover
CUSTOMER FUEL CONNECTION
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
3.6 CLEAN SPARK ARRESTOR
The engine exhaust muffler has a spark arrestor screen. Inspect and
clean the screen every 200 hours of operation or once each year,
whichever comes first.
nDo NOT use a forceful spray of water to
clean the generator. Water will enter the gen-
erator interior and cause problems, and may
also contaminate the generator fuel system.
NOTE:
If using the generator on any forest-covered, brush-covered or
grass-covered unimproved land, it must equipped with a spark
arrestor. The spark arrestor must be maintained in good condi-
tion by the owner/operator.
3.8 BATTERY MAINTENANCE
NOTE:
This generator is not equipped with an internal battery charger.
It is intended for use in systems where an external battery char-
ger is installed by the RV O.E.M. or an aftermarket installer.
Clean and inspect the spark arrestor as follows:
• Remove the screen by removing the screw.
• Slide the spark arrestor screen out from the tail pipe.
• Inspect screen and replace if torn, perforated or otherwise
damaged. DO NOT USE a defective screen. If screen is not
damaged, clean it with commercial solvent.
All lead-acid batteries will discharge when not in use. The generator
battery should be inspected as follows:
3.8.1 WEEKLY
• Replace the screen and the screw.
• Inspect the battery posts and cables for tightness and corro-
sion. Tighten and clean as necessary.
Figure 3.6 - Spark Arrestor
• Check the battery fluid level of unsealed batteries and, if nec-
essary, fill with Distilled Water Only. Do not use tap water in
batteries.
3.8.2 EVERY SIX MONTHS
• Have the state of charge and condition checked. This should be
done with an automotive-type battery hydrometer.
TAILPIPE
P/N 0G5857
NOTE:
Servicing of the battery is to be performed or supervised by
personnel knowledgeable of batteries and the required precau-
tions. Keep unauthorized personnel away from batteries.
SPARK ARRRESTOR
SCREEN P/N 089680
Damage will result if the battery connections are made in
reverse.
RETAINING
SCREW P/N 056892
Do not dispose of the battery in a fire. The
battery is capable of exploding. Storage bat-
3.7 CLEANING THE GENERATOR
Keep the generator set as clean and dry as possible. Protect the
unit against excessive dust, dirt, corrosive vapors, road splash,
etc. Permitting dirt and moisture to accumulate on generator
windings will have an adverse effect on the insulation resistance
of those windings.
teries give off explosive hydrogen gas. This
gas can form an explosive mixture around
the battery for several hours after charging.
The slightest spark can ignite the gas and
cause an explosion. Such an explosion can
shatter the battery and cause blindness or
other injury. Any area that houses a storage
battery must be properly ventilated. Do not
allow smoking, open flame, sparks, or any
spark producing tools or equipment near the
battery. Discharge static electricity from body
before touching the battery by first touching
a grounded metal surface.
When moisture is allowed to remain in contact with windings,
some of the moisture will be retained in voids and cracks in the
insulation. This causes a reduced insulation resistance and will
eventually cause problems. Dirt will make the problem worse,
since dirt tends to hold moisture in contact with windings. Salt (as
from sea air) also will worsen the problem since it tends to absorb
moisture from the air. Salt and moisture, when combined, form a
good electrical conductor which is detrimental to the generator.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
A battery presents a risk of electrical shock
and high short circuit current. The following
precautions are to be observed when work-
ing on batteries:
• Make sure the piston is at Top Dead Center (TDC) of its com-
pression stroke (both valves closed). To get the piston at TDC,
remove the intake screen at the front of the engine to gain
access to the flywheel nut. Use a large socket and socket
wrench to rotate the nut and hence the engine in a clockwise
direction. While watching the piston through the spark plug
hole. The piston should move up and down. The piston is at
TDC when it is at its highest point of travel.
• Remove watches, rings or other metal objects;
• Use tools with insulated handles;
• Wear rubber gloves and boots;
• Do not lay tools or metal parts on top of the
battery;
To adjust valve clearance (if necessary):
• Disconnect any charging source prior to connect-
ing or disconnecting battery terminals; and
• Do not use any jumper cables or booster battery
to crank and start the generator engine. If any
battery has discharged, remove it for recharging.
• Make sure the engine is at 60° to 80° F.
• Make sure that the spark plug wire is removed from the spark
plug and out of the way.
• Remove the four screws attaching the valve cover with a #2 or
#3 Phillips screwdriver.
• Loosen the rocker jam nut. Use an 10mm allen wrench to turn
the pivot ball stud while checking clearance between the rocker
arm and the valve stem with a feeler gauge. Correct clearance
is 0.002-0.004 inch (0.05-0.1 mm). (Figure 3.7).
Do not open or mutilate the battery.
Released electrolyte has been known to
nꢀ
be harmful to the skin and eyes, and to be
toxic.
Figure 3.7 - Valve Clearance Adjustment
The electrolyte is a dilute sulfuric acid that
is harmful to the skin and eyes. It is electri-
nꢀ
Rocker
Arm
cally conductive and corrosive. The follow-
ing procedures are to be observed:
Pivot Ball
Stud
Jam Nut
• Wear full eye protection and protective clothing;
• Where electrolyte contacts the skin, wash it off
immediately with water;
Valve
Stem
• Where electrolyte contacts the eyes, flush
thoroughly and immediately with water and
seek medical attention; and
• Spilled electrolyte is to be washed down with
an acid neutralizing agent. A common practice
is to use a solution of 1 pound (500 grams)
bicarbonate of soda to 1 gallon (4 liters) or
water. The bicarbonate of soda solution is to
be added until the evidence of reaction (foam-
ing) has ceased. The resulting liquid is to be
flushed with water and the area dried.
NOTE:
3.9 ADJUSTING VALVE CLEARANCE
Hold the rocker arm jam nut in place as the pivot ball stud is
turned.
After the first 50 hours of operation, check the valve clearance
in the engine, adjust if necessary.
When valve clearance is correct, hold the pivot ball stud in place
with the allen wrench and tighten the rocker arm jam nut. Tighten
the jam nut to 174 in/lbs. torque. After tightening the jam nut,
recheck valve clearance to make sure it did not change.
Important: If feeling uncomfortable about doing this procedure or
the proper tools are not available, please contact the Authorized
Dealer for service assistance. This is a very important step to
insure longest life for the engine.
• Install new valve cover gasket.
• Re-attach the valve cover.
NOTE:
To check valve clearance:
• The engine should be cool before checking. If valve clearance is
0.002" - 0.004" (0.05 - 0.1mm), adjustment is not needed.
• Remove spark plug wires and position wires away from plugs.
• Remove spark plugs.
Start all four screws before tightening or it will not be possible
to get all the screws in place. Make sure the valve cover gasket
is in place.
• Install spark plugs.
• Re-attach the spark plug wire to the spark plug.
• On the GT-530, repeat the process for the other cylinder.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
3.13.2 RETURN TO SERVICE
To return the unit to service after storage, proceed as follows:
3.10 MAJOR SERVICE MANUAL
To obtain a service manual for the generator, contact the near-
est Authorized Service Dealer. Make sure to identify the MODEL
NUMBER and SERIES.
1. Check the tag on the engine for oil viscosity and classification.
Verify that the correct recommended oil is used in the engine
(see "Engine Oil Requirements"). If necessary, drain and refill
with the proper oil.
2. Check the state of the battery. Fill all cells of unsealed batter-
ies to the proper level with distilled water. DO NOT USE TAP
WATER IN THE BATTERY. Recharge the battery to 100 percent
state of charge, or, if defective, replace the battery.
3. Clean and wipe the entire generator.
3.11 DRIVE BELT
The engine drives the generator rotor by means of a pulley and
drive belt arrangement. Drive belt tension was properly adjusted
before the unit was shipped from the factory. If suspect that drive
belt tension is incorrect, contact an Authorized Service Dealer.
4. Reconnect the battery. Observe battery polarity. Damage may
3.12 EXERCISING THE GENERATOR
The manufacturer recommends starting and operating the genera-
tor at least once every seven days. Let the unit run for at least 30
minutes to “exercise” the engine.
occur if the battery is connected incorrectly.
5. Turn OFF all electrical loads. Add fuel if necessary and then
start the engine.
6. Allow the unit to warm up thoroughly.
7. Apply electrical loads to at least 50 percent of the unit’s rated
3.13 OUT OF SERVICE PROCEDURE
wattage capacity.
8. When the engine is thoroughly warmed up, shut it down.
9. The generator is now ready for service.
3.13.1 REMOVAL FROM SERVICE
If the generator cannot be exercised every seven days, and it is to
be out of service longer than 30 days, prepare the generator for
storage as follows:
3.14 RV GENERATOR SERVICE
INTERVAL
1. Start the engine and let it warm up.
1st 8 Hours,
2. Close the fuel shutoff valve in the fuel supply line and allow
then every 200 Hours......................... Change Engine Oil/Filter
1st 50 Hours,
the unit to shut down.
3. While the engine is still warm from running, drain the oil
completely. Refill the crankcase with SAE 5W-30 oil having
API classification “For Service SJ/SL.”
then every 500 Hours.................................. Adjust Valve Lash
200 Hours ..................................................Clean Spark Arrestor
200 Hours .................................Replace Paper Air Filter Element
400 Hours ......................................................Replace Fuel Filter
500 Hours ..................................................Replace Spark Plugs
4. Attach a tag to the engine indicating the viscosity and clas-
sification of the oil in the crankcase.
5. Remove the spark plug and pour two or three tablespoons of
clean, fresh engine oil into the spark plug threaded openings.
Reinstall and tighten the spark plug.
6. Remove the battery and store it in a cool, dry room on a
wooden board. Never store the battery on any concrete or
earthen floor.
7. Clean and wipe the entire generator.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Part II - Installation Instructions
Part II –
Installation
Instructions
ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS
SHOULD ATTEMPT INSTALLATION!
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Rules
nDANGER: For fire safety, installation of a generator into a recreational vehicle must comply strictly with
article 551, NFPA 70; ANSI C1-1975; AND, ANSI A119.2-1975/NFPA 501C “Standard for Recreational
Vehicles” (Part 3, “Installation of Electrical Systems”). In addition, installation must comply with the man-
ufacturer’s instructions and recommendations.
NOTICE TO INSTALLER
GENERAL HAZARDS
These Installation Instructions have been published by the manu-
facturer to aid in the installation of the products described in this
manual. The manufacturer assumes that installation personnel
are familiar with the procedures for installing such products, or
similar products manufactured. The manufacturer also assumes
that personnel have been trained in the recommended installation
procedures for these products and that such training includes (a)
use of common hand tools, (b) use of special tools, and (c) use of
any tools and/or equipment from other suppliers.
• For safety reasons, the manufacturer recommends that the
installation, initial start-up and maintenance of this equipment
is carried out by an Authorized Service Dealer.
• The generator engine releases DEADLY carbon monoxide gas
through its exhaust system. This dangerous gas, if breathed
in sufficient concentrations, can cause unconsciousness or
even death. Never operate the generator set with the vehicle
inside any garage or other enclosed area. Shut down the
generator and do not operate it until it has been inspected
and repaired.
The manufacturer cannot possibly know of and advise the rec-
reational vehicle trade of all conceivable methods, procedures or
techniques by which to perform an installation. Nor can the manu-
facturer anticipate every possible hazard that might result from
each installation method, procedure or technique. The manufactur-
er has not undertaken any such wide evaluation. Therefore, people
who use a method, procedure or technique that the manufacturer
does not specifically recommend must first completely satisfy
themselves that their safety, the safety of the vehicle's occupants
and the product's safety is not endangered by the method, proce-
dure or technique selected.
• DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM
IS LEAKING OR HAS BEEN DAMAGED.
• SYMPTOMS OF CARBON MONOXIDE POISONING ARE (a)
inability to think coherently, (b) nausea, (c) vomiting,
(d) twitching muscles, (e) throbbing temples, (f) dizzi-
ness, (g) headaches, (h) weakness, and (i) sleepiness. IF
EXPERIENCING ANY OF THESE SYMPTOMS, MOVE INTO
FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET
MEDICAL HELP.
• Never sleep in the vehicle while the genset is running unless
the vehicle has a working carbon monoxide detector. The
exhaust system must be installed in accordance with the
genset installation manual. Make sure there is ample fresh
air when operating the genset in a confined area.
• Keep hands, feet, clothing, etc., away from drive belts, fans,
and other moving or hot parts. Never remove any drive belt or
fan guard while the unit is operating.
Information, illustrations, specifications, etc., contained in these
Installation Instructions are based on the latest information avail-
able at the time of publication. Every effort has been expended
to be sure that such data is both accurate and current. However,
the manufacturer reserves the right to change, alter or otherwise
improve this product at any time without prior notice.
• Adequate, unobstructed flow of cooling and ventilating air is
critical to correct generator operation and is required to expel
toxic fumes and fuel vapors from the generator compartment.
Without sufficient cooling airflow, the engine/generator quickly
overheats, which causes serious damage to the generator. Do
not alter the installation or permit even partial blockage of ven-
tilation provisions, as this can seriously affect safe operation of
the generator.
• When working on this equipment, remain alert at all times.
Never work on the equipment when physically or mentally
fatigued.
• Before performing any maintenance on the generator, discon-
nect its battery cables to prevent accidental start up. Disconnect
the cable from the battery post indicated by a NEGATIVE, NEG
or (–) first. Reconnect that cable last.
nDespite the safe design of this generator,
operating this equipment imprudently, neglect-
ing its maintenance or being careless can
cause possible injury or death. Permit only
responsible and capable persons to operate
or maintain this equipment.
Potentially lethal voltages are generated by
these machines. Ensure all steps are taken to
render the machine safe before attempting to
work on the generator.
nParts of the generator are rotating and/or hot
during operation. Exercise care near running
generators.
• Never use the generator or any of its parts as a step. Stepping
on the unit can stress and break parts, and may result in dan-
gerous operating conditions from leaking exhaust gases, fuel
leakage, oil leakage, etc.
• Never insert any tool or other object through openings in the
generator interior, even if the unit is not running. Serious injury
or damage to the equipment could be done.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Rules
ELECTRICAL HAZARDS
FIRE HAZARDS
• The generator covered by this manual produces dangerous
electrical voltages and can cause fatal electrical shock. Avoid
contact with bare wires, terminals, connections, etc., while the
unit is running. Ensure all appropriate covers, guards and bar-
riers are in place before operating the generator. If work must
be done around an operating unit, stand on an insulated, dry
surface to reduce shock hazard.
• Do not handle any kind of electrical device while stand-
ing in water, while barefoot, or while hands or feet are wet.
DANGEROUS ELECTRICAL SHOCK MAY RESULT.
• During installation onto the vehicle, properly ground (bond) the
generator either by solid mounting to the vehicle frame or chas-
sis, or by means of an approved bonding conductor. DO NOT
connect the bonding conductor to any generator part that might
be removed or disassembled during routine maintenance. If
the grounding conductor must be replaced, use only a flexible
conductor that is of No. 8 American Wire Gauge (AWG) copper
wire minimum.
• For fire safety, the generator must be installed and maintained
properly. Installation always must comply with applicable
codes, standards, laws and regulations. Adhere strictly to local,
state and national electrical and building codes. Comply with
regulations the Occupational Safety and Health Administration
(OSHA) has established. Also, ensure that the generator is
installed in accordance with the manufacturer’s instructions
and recommendations. Following proper installation, do noth-
ing that might alter a safe installation and render the unit in
noncompliance with the aforementioned codes, standards,
laws and regulations.
• Keep a fire extinguisher in the vehicle at all times. Extinguishers
rated “ABC” by the National Fire Protection Association are
appropriate for use on the recreational vehicle generator electrical
system. Keep the extinguisher properly charged and be familiar
with its use. If there are any questions pertaining to fire extin-
guishers, consult the local fire department.
• If the vehicle electrical circuits can be powered by any other
source of electricity (such as a “dockside” power receptacle),
there must be no possibility of connecting the different power
sources to the vehicle circuits at the same time. The dockside
(utility) power source must be positively isolated from the
vehicle circuits whenever the generator is operating. Failure to
isolate the vehicle circuits from the dockside power supply when
the generator is running may result in damage to the generator
or serious injury or death to dockside (utility) power workers due
to backfeed of electrical energy.
• In case of accident caused by electric shock, immediately shut
down the source of electrical power. If this is not possible,
attempt to free the victim from the live conductor. AVOID DIRECT
CONTACT WITH THE VICTIM. Use a nonconducting implement,
such as a rope or board, to free the victim from the live conduc-
tor. If the victim is unconscious, apply first aid and get immediate
medical help.
EXPLOSION HAZARDS
• Do not smoke around the generator. Wipe up any fuel or oil spills
immediately. Ensure that no combustible materials are left in the
generator compartment, or on or near the generator, as FIRE or
EXPLOSION may result. Keep the area surrounding the generator
clean and free from debris.
• GasolineisextremelyFLAMMABLEanditsvaporsareEXPLOSIVE.
Do not permit smoking, open flame, sparks or any source of
heat in the vicinity while handling gasoline. Comply with all laws
governing the storage and handling of gasoline.
• Fuel lines must be properly installed and fastened, and free of
leaks. There must be no possibility of gasoline vapors entering
the vehicle interior.
• It is required that an approved, flexible, nonconductive fuel line
between the generator fuel connection point and rigid fuel lines
be installed.
• Never wear jewelry when working on this equipment. Jewelry
can conduct electricity resulting in electric shock, or may get
caught in moving components causing injury.
• If the generator is equipped with a liquid propane (LP) gas fuel
system, install the unit so it complies with all codes, standards
and regulations pertaining to such systems. LP gas is highly
explosive. The gas tends to settle in low areas where even the
slightest spark can ignite it and cause an explosion. Do not
allow gas vapors to enter the vehicle.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information
1.1 PURPOSE AND SCOPE OF THE
1.4 EQUIPMENT DESCRIPTION
Instructions and information in this section pertain to air-cooled
generators. These generators are designed specifically for install-
ing in recreational vehicles. They operate 120-volt, single-phase,
60-Hertz, AC electrical loads.
INSTALLATION INSTRUCTIONS
These Installation Instructions have been prepared especially for
the purpose of familiarizing installers and owners of the applicable
equipment with the product's installation requirements. Give seri-
ous consideration to all information and instructions in the manual,
both for safety and for continued reliable operation of the equip-
ment.
1.5 GENERATOR ENGINE
OPERATING SPEED
The generator’s revolving field (rotor) is driven by a two-cylinder,
four-cycle engine through a pulley and drive belt arrangement. The
generator supplies 120 volts AC at 60 Hertz when the rotor is oper-
ating at 3,600 rpm. The drive belt arrangement allows the engine to
operate at a lower speed than the rotor.
Because of the different recreational vehicle models and the
variations between the models, it would be extremely difficult, if
not impractical, to provide detailed instructions for every possible
installation. For that reason, instructions and illustrations in this
manual are general in nature. Illustrations are not intended to serve
as detailed installation blueprints.
1.6 GENERATOR AC
The installation should comply strictly with all applicable codes,
standards and regulations pertaining to the installation and use of
this product. If any portion of this manual appears to be in conflict
with such codes, standards or regulations, the applicable codes,
standards or regulations must take precedence over the manual.
CONNECTION SYSTEM
These air-cooled generator sets are equipped with dual stator AC
power windings. These two stator windings supply electrical power
to customer electrical loads by means of a dual 2-wire connection
system.
Generators may be installed to provide the following outputs:
1.2 SAFETY
Before handling, installing, operating or servicing this equipment,
carefully read the “Notice to Installer” and “Safety Rules”. Comply
with all safety rules to prevent death, personal injury or damage to
equipment and/or property. Stress safety to all installers, operators
and service technicians who work on this equipment.
1. 120 VAC loads only — two loads each, with a maximum total
wattage requirement equal to half of the generator’s rated
power output (in watts), and 120V across the generator out-
put terminals (see Fig. 1.1).
2. 120/240 VAC loads — one load with a maximum total wattage
requirement equal to the generator’s rated power output, and
240V across the generator output terminals; or two separate
loads, each with a maximum total wattage requirement equal
to half of the generator’s rated power output (in watts), and
120V across the generator output terminals (see Fig. 1.3).
1.3 STANDARDS BOOKLETS
Installation, use and servicing of this equipment should comply
strictly with published standards, as well as the manufacturer's
recommendations. The following standards booklets (latest revi-
sion) are available from the sources indicated:
Figure 1.1 – Connection for 120 Volts Only
1. NFPA Standard 501C, “Standard for Recreational Vehicles,”
available from the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269.
2. NFPA 70, “NFPA Handbook of the National Electric Code,”
available same as Item 1.
3. ANSI C1-1975 and ANSI 119.2-1975, available from the
American National Standards Institute, 1430 Broadway, New
York, NY 10018.
4. ANSI A119.2/RVIA EGS-1, available from the Recreational
Vehicle Association, 1896 Preston White Drive, Reston, VA
22090.
5. California Administrative Code, Title 25, available from the
State of California, Documents Section, P.O. Box 1015, North
Highlands, CA 95660.
6. CSA Electrical Bulletin 946, available from the Canadian
Standards Association, Housing and Constructions Materials
Section, 178 Rexdale Boulevard, Rexdale, Ontario, Canada,
M9W 1R3.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 1.2 - Major Features and Dimensions (Drawing No. 0G5519-D)
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
• The location must provide sufficient room to allow minimum
clearances as outlined in "Generator Compartments". If sound
insulation is to be used on the compartment walls and ceiling,
the minimum recommended applies to the space between the
generator and such insulation.
Figure 1.3 - Connection for 120/240 Volts
T1
RED
CB1
• The location must provide adequate cooling and ventilating
airflow for the generator without a great deal of work and
expense.
• If mounting the generator in an enclosed compartment, the base
of the generator must rest flat on the floor without any gaps.
• When using a suspended mounting system, ensure the base of
the generator is flush with the surrounding bodywork. If the unit
is mounted higher in the structure, heated air may recirculate
into the generator causing it to overheat.
T2
WHITE
2.1.2 GENERATOR SUPPORT
CB2
T3
BLACK
The generator must be securely attached to a metal framework that
has been made part of the vehicle frame structure by bolting or
welding. The metal framework on which the generator will rest and
which will restrain the generator set should consist of at least two
horizontal beams. These beams should consist of (a) 1-1/2-inch
square, 11-gauge steel tubing OR (b) 1-1/2-inch, 11-gauge angle
iron. A typical supporting frame with horizontal support tubing, is
shown in Figure 2.1.
GROUNDED NEUTRAL
STATOR POWER
WINDINGS
• The AC connection system on air-cooled generators uses a
GROUNDED neutral.
• A separate green ground wire is connected to the recreational
vehicle’s junction box.
• Total load connected across T1 (Red) to T2 (White), and T3
(Black) to T2 (White), must not exceed rating for the specific
generator (see "Generator Specifications").
NOTE:
Figure 2.1 – Typical Horizontal Support Frame
Do NOT connect loads in excess of circuit breaker ratings.
2.1 LOCATION AND SUPPORT
2.1.1 GENERATOR LOCATION
NOTE
Be sure the installation complies with all standards and codes
listed in the "Standards Booklets" section of this manual.
The most desirable location for the generator set is between the
vehicle's main frame members. However, this is seldom possible.
Most units must be installed on the side of the vehicle and are
difficult to reinforce.
The generator can be installed so that it sits on top of the horizontal
support tubing if the vehicle design permits. Another method is
to suspend the generator below the horizontal support tubing by
means of suitable, structurally sound metal framework. The fol-
lowing general rules apply:
Many recreational vehicles have been factory equipped with an
area for the generator set. Some vehicles may even have a genera-
tor compartment provided by the vehicle manufacturer.
• Vehicle construction MUST be capable of supporting the weight
of the generator.
• Whether the generator is mounted above the horizontal support
tubing or suspended below the tubing, the supporting frame
used must be structurally sound.
• If the generator cannot be bolted directly to the supporting
frame or support tubing, consider using additional tubing,
angle brackets or other supports to give the supporting frame
sufficient strength.
Plan the generator location based on the following:
• The generator set must be installed on a framework that is
part of the recreational vehicle, as outlined in the "Generator
Support" section.
• The location must provide an access opening that is large
enough to permit generator removal (unless the generator is to
be removed from underneath the supporting framework).
• The location must provide easy access to frequently serviced
components, such as filters, oil drains, spark plugs and other
common maintenance parts.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
2.1.3 SUSPENDED MOUNTING
2.2 GENERATOR COMPARTMENTS
Whether the generator set is being installed inside a compartment
specifically manufactured to house a generator or inside a compart-
ment that the installer constructs, the compartment MUST meet
certain specifications as outlined in the following sections:
If planning to suspend the generator below the horizontal sup-
port tubing, the suspension method to use with the vehicle frame
members must (a) be able to support the weight of the generator
AND (b) provide sufficient restraint for the generator. One typical
suspended mounting system is shown in Figure 2.2. The location
of a suspended mounting system must be carefully planned, keep-
ing the following general rules in mind:
2.2.1
COMPARTMENT SIZE
Plan the compartment size carefully. Provide a minimum clearance
of 1/2 inch (13 mm) on the front top, sides, and from the back for
air circulation AFTER the compartment has been lined with metal
and sound insulation (Figure 2.4).
• Protect the generator against road splash and debris. Baffles or
splash guards may be required to protect certain areas of the
generator. To make sure the generator is adequately protected,
road test the installation through mud, water and slush.
NOTE:
Refer to “Figure 1.2 – Major Features and Dimensions”.
Figure 2.2 – Typical Suspended Mounting System
Figure 2.4 – Clearances
Plywood
Compartment
1/2" Clearance on Top
1/2" Clearance
in Back
1/2" Each Side
• The installer must make certain that the selected location will
permit adequate cooling and ventilating airflow to be supplied.
1/2"
Insulation
in Front
2.1.4 GENERATOR RESTRAINT
Use four 3/8"-16 hardened steel bolts (Grade 5) to fasten the
generator to the supporting frame or the support tubing. These
bolts must pass through (a) the generator mounting base, (b) the
compartment floor (if a compartment is used) and (c) the support-
ing framework (Figure 2.3). All bolts must be long enough so that
when tight, at least three threads are visible past the retaining lock
nuts. Refer to "Generator Compartments" for the location of the
generator mounting holes. Torque Bolts to 31 ft./lbs..
2.2.2 COMPARTMENT CONSTRUCTION
• The generator compartment should be either constructed of, or
lined with, 26-gauge galvanized steel.
NOTE:
Figure 2.3 – Typical Generator Restraint
Aluminum is NOT an acceptable alternative to galvanized steel
due to aluminum’s low melting point.
• If the compartment is lined with galvanized steel, it may be
constructed of any material. The manufacturer recommends
that the compartment be constructed of 1/2-inch thick plywood
(not strandboard), with the floor made of a double thickness of
1/2-inch plywood with the grain of the wood at cross section
for added strength (Figure 2.5).
• If constructing a compartment, line the exterior (underside) of
the compartment floor with 26-gauge galvanized steel.
• All seams, splices and joints of the compartment walls (unless
vapor tight by design) should be caulked to prevent poison-
ous, flammable or explosive vapors from entering the vehicle
interior.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 2.5 – Typical Compartment Construction
Figure 2.6 – Types of Lock Seams
Do not install any flammable material directly
above or around the compartment. Heat,
transferred through the compartment struc-
ture, may be sufficient to ignite, char or dis-
color seat cushions, fiberboard and other
flammable materials. Use approved nonflam-
mable insulating materials in high tempera-
ture areas.
2.2.3 SOUND INSULATING MATERIALS
NOTE:
Once installers have determined that a compartment is properly
constructed and metal lined, they can add acoustical material.
This may include additional sealant or insulating material, to reflect
noise away from the vehicle interior.
Caulking must be done so that the caulking material will stay in
place permanently. Pressing such materials as putty tape onto
joints and seams is not acceptable. A high quality silicone rub-
ber base sealant is recommended.
Sound insulating materials should be of a nonflammable type. One
excellent insulating material is a 1-inch (25 mm) thick fiberglass
having a 2-pound density. When fiberglass is used, its coated side
should face toward the compartment interior.
• Holes and openings made in the compartment walls to allow for
the passage of electrical conduit, conductors, hoses, cables,
etc., into the vehicle living area must be sealed vapor tight with
silicone rubber base sealant.
• If flexible metal conduit is used, it must be sealed internally at
the end where it terminates inside the compartment’s electrical
junction box.
Do not install sound insulation or any absor-
bent material on the compartment floor inte-
NOTE:
rior. Such materials will become soaked with
combustible or explosive vapors and liquids
and will become a fire hazard.
Flexible metal conduit, due to its unique construction, is NOT
vapor tight along its entire length.
• Seams and joints of the galvanized steel (whether used as a liner
or for the compartment itself) must be lapped and mechanically
secured. Such seams may be manufactured, welded, bolted,
riveted or screwed. Manufactured lock seams are shown in
Figure 2.6. Installer constructed compartments typically utilize
a standard lap joint.
Using a combination of sound insulating materials can often
reduce noise more effectively than a single material. For example,
a sheet of lead or visco-elastic material, along with a layer of other
acoustical material, is more effective than when a single material
is used.
• After the compartment has been metal lined and vapor
sealed, line the compartment interior walls and ceiling with an
approved, nonflammable sound insulating material. See "Sound
Insulating Materials".
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
2.2.4 ACOUSTICS
2.2.5 COMPARTMENT FLOOR CUTOUTS
For additional noise abatement, the installer may wish to consider
the following:
Provide openings in the generator compartment for the following
items (Figure 2.9):
• Using special sound insulating materials.
• Construction of a special noise abatement compartment.
NOTE:
• Engine exhaust and cooling air outlets
• Generator cooling air inlet
• Four holes for passage of generator mounting bolts. See
"Generator Restraint".
Any method used to reduce noise must not adversely affect the
flow of cooling and ventilating air into or out of the compart-
ment.
nFuel lines and exhaust piping must not pen-
etrate into the vehicle living area.
In addition to the effective use of sound insulating materials,
construction of a special noise abatement compartment might be
considered to reduce noise levels. Such a compartment might be
constructed as follows (Figure 2.7):
2.3 COOLING AND VENTILATING
• Use 5/8-inch thick or 3/4-inch thick plywood in the compart-
ment.
AIR
It is absolutely essential that an adequate flow of air for cooling,
ventilating and engine combustion be supplied to the generator set.
Without sufficient airflow, the engine/generator quickly overheats.
Such overheating can cause serious operating difficulties and also
may cause fire and personal injury. The installer must make sure
that sufficient air is available to the generator for cooling, ventilat-
ing and combustion. The installer also must provide for a path for
exhausting the cooling air to the exterior of a compartment, if so
equipped.
• Construct the compartment floor of a double thickness of 5/8-
inch or 3/4-inch plywood.
• Line the compartment interior walls and floor, as well as the
underside of the floor, with 26-gauge galvanized steel.
• Vapor seal all compartment seams and joints.
• Over the galvanized steel lining, install a combination of acousti-
cal materials as mentioned in "Sound Insulating Materials".
To prevent fire or explosion, do not install
any insulation or other absorbent materials
Never use discharged cooling air for heating
or permit such air to enter the vehicle inte-
rior. This air contains deadly carbon monox-
ment floor.
ide gas and other poisonous, flammable or
explosive gases.
• Seal all compartment door edges to prevent noise leakage
around the door perimeter.
2.3.1 GENERATOR AIRFLOW
Figure 2.7 – Typical Noise Abatement
Engine operation drives cooling fans for the two-stage cooling
air system. A pressure fan draws cooling air into the top of the
generator (Figure 2.8). This airflow cools the engine/generator and
electronic components. The second part of the cooling system, a
suction fan, draws air that is heated from a hot engine into a col-
lector pan at the base of the unit. This heated air (although cooler
than exhaust muffler) is then deflected out the bottom toward the
ground.
Figure 2.8 – Airflow Through Engine/Generator
COOLING AIR IN
ENGINE AIR IN
COOLING
AIR OUT
• Line the compartment door interior (except for air openings)
with suitable, fireproof sound insulation (such as 1-inch (25
mm) thick fiberglass with a 2-pound density).
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 2.9 — Compartment Floor Cutout (Drawing 0G4432-A)
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
If the generator is to share the vehicle engine's tank, separate
fuel pickup tubes are required for the engine and the generator.
The manufacturer recommends that the fuel pickup tube be two
to three inches (51 to 76 mm) shorter than the vehicle engine's
pickup tube. This prevents the generator from depleting the entire
fuel supply during prolonged generator operating periods.
6.3.2 TESTING THE INSTALLATION
The manufacturer recommends testing the installation to be sure
adequate cooling airflow is available to the unit before placing the
unit into service. If the unit shows signs of overheating, enlarge the
air openings. Never place a unit into service until absolutely certain
that cooling and ventilation is adequate.
Gasoline generators are equipped with an Evaporative Emissions
Port that may be used in conjunction with a certified fuel system
where required by law.
NOTE:
The installation must be tested, especially if bringing in air from
below the generator set.
nDo NOT tee the generator fuel supply line
into the vehicle engine fuel supply line. If
2.4 GASOLINE FUEL SYSTEM
this is done, the generator will be starved of
fuel when both engines are operating at the
same time. Also, while the vehicle engine is
not running, generator operation may drain
the vehicle engine supply line, making it dif-
ficult to start the vehicle engine.
Gasoline is highly flammable, and its vapors
are explosive. Comply with all codes, stan-
dards and regulations pertaining to gasoline
fuel systems used in recreational vehicle
generators. Properly install and maintain
the fuel system and keep it entirely free of
leaks. Gasoline vapors must not enter the
vehicle interior.
2.4.2 GENERATOR FUEL SUPPLY LINE
2.4.2.1 Rigid Fuel Lines
Those lines used to supply fuel from a tank to the generator must
comply with applicable codes, standards and regulations. The fol-
lowing general rules apply to rigid fuel lines:
The installation of a gasoline fuel system (Figure 2.10) for a
recreational vehicle generator set must comply with applicable
codes, standards and regulations. The entire fuel system must be
completely free of leaks. There must be no possibility of gasoline
vapors entering the vehicle interior.
• Rigid lines should be of annealed, seamless, drawn aluminum
or steel.
Figure 2.10 – Generator Fuel System
• Lines and fittings must comply with SAE J512F, “Standard
Automotive Fittings,” or with ANSI B126.26 (latest edition).
• Route the fuel line so that at least 2 inches (51 mm) of clear-
ance is maintained between the line and any exhaust system
parts.
• Do not attach electrical wiring to fuel lines. Route the wiring so
it cannot come into contact with any fuel line.
• Route fuel lines so if they leak, fuel does not drip onto any
electrical or exhaust system parts.
• Use nonferrous metal straps without sharp edges to secure
fuel lines.
2.4.2.2 Flexible Fuel Line
a, b
e
d
Use an approved flexible length of fuel hose between the generator
fuel inlet connection and rigid fuel lines. This prevents breaking of
the line caused by vibration, shifting, settling or movement. The
following rules apply:
Factory installed generator fuel system components include (a)
fuel filter, (b) 12-volt DC electric pump, (c) engine carburetor, and
(d) interconnecting lines and fittings, (e) evaporative port. Connect
a fuel supply line to the fuel filter inlet. Use a flexible length of
approved fuel hose between the fuel filter inlet connection and
rigid fuel lines.
• The flexible hose must comply with SAE J30R7, “Standard for
Fuel and Oil Hose.” It must be approved for use with gasoline
and low permeability.
• The hose should be at least 6 inches (152 mm) longer than
is needed to prevent the hose from rupturing if the generator
shifts or settles.
2.4.1 FUEL TANK
Either the generator must share the vehicle engine's fuel tank, or a
separate fuel tank for the generator set must be installed. All fuel
tanks installed on the vehicle must be constructed, installed and
restrained so they comply with applicable codes, standards and
regulations. The generator has an evaporative emissions port to
evacuate accumulated gasoline vapors when necessary.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 2.11 - Spark Arrestor
2.5 EXHAUST SYSTEM
The generator exhaust system must be safely and properly
installed. Only approved mufflers and other exhaust system parts
must be used. A properly installed exhaust system must be vapor
tight, quiet and completely safe.
TAILPIPE
P/N 0E0683
nThe generator engine gives off DEADLY
carbon monoxide gas through its exhaust
system. This dangerous gas, if breathed in
sufficient concentrations, can cause uncon-
sciousness or even death. Never operate
the generator set with the vehicle inside
any garage or other enclosed area. DO
NOT OPERATE THE GENERATOR IF THE
EXHAUST SYSTEM IS LEAKING OR HAS
BEEN DAMAGED. SYMPTOMS OF CARBON
MONOXIDE POISONING ARE (a) inability to
think coherently; (b) vomiting; (c) twitch-
ing muscles; (d) throbbing temples; (e)
dizziness; (f) headaches; (g) weakness;
and (h) sleepiness. IF FEELING ANY OF
THESE SYMPTOMS, MOVE INTO FRESH AIR
IMMEDIATELY. IF SYMPTOMS PERSIST, GET
MEDICAL HELP. Do not operate the generator
until its exhaust system has been inspected
and properly repaired.
SPARK ARRRESTOR
SCREEN P/N 089680
RETAINING
SCREW P/N 056892
Figure 2.12 — Spark Arrestor Installation
nNever tee the generator engine exhaust pipe
into the vehicle engine exhaust piping. This
causes excessive back pressure on the gen-
erator engine. Also, water from one engine
can damage the other engine.
2.5.2 EXHAUST SYSTEM SAFETY
• Maintain a clearance of at least 3 inches (76 mm) between
exhaust system parts and any combustible material (such as
wood, felt, cotton, organic fibers or other like material). If the
3-inch (76 mm) clearance cannot be maintained, locate, insu-
late or shield the exhaust part(s) so that the temperature of any
combustible material is not raised more than 117° F (65° C)
above the ambient air temperature.
• Extend the exhaust system at least 1 inch (25 mm) past the
outer edge of the vehicle. Do not terminate the exhaust system
under the vehicle.
2.5.1 MUFFLERS AND SPARK ARRESTORS
This muffler meets code and standard requirements of the U.S.
Forest Service. Use only mufflers and parts approved by the
manufacturer. Any person(s) installing an unapproved muffler,
or an unapproved exhaust system part, or modifying an exhaust
system in any way that might cause a hazard, is liable for any
damage, injury or warranty expense that might be caused by such
unapproved installation or modification.
• Terminate the exhaust tailpipe such that exhaust gases will not
be drawn back into the generator compartment and recircu-
lated.
• If there is any possibility of the tailpipe or muffler being dam-
aged, protect these damage-prone areas by means of a protec-
tive device (such as a skid bar).
Failure to provide and maintain a spark arrestor may be in violation
of the law. If this generator is used on any forest covered, brush
covered or grass covered unimproved land, a spark arrestor must
be provided. The vehicle owner or operator must maintain this
device in good condition. In the state of California, the preceding
is required by law (Section 4442 of the California Public Resources
Code). Other states may have similar laws. Federal laws apply on
federal lands.
• Install the generator exhaust system according to safe automo-
tive practices.
• Use enough exhaust system hangers to prevent any part of the
system from being dislocated.
• Use exhaust system parts recommended by the manufacturer.
Using unapproved exhaust mufflers and exhaust system parts
is the responsibility of the person(s) installing such unauthor-
ized parts.
When installing/replacing the tailpipe or spark arrestor compo-
nents, verify that the tailpipe has a hole to securely fasten the
spark arrestor components (see Figures 2.11 and 2.12). Use only
manufacturer supplied hardware. Substitution of parts may cause
damage to the screen or a loose fit to the tailpipe.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
• Do not terminate the exhaust system under any opening, win-
dow or vent that can be opened or is not permanently sealed
from the vehicle interior.
• From the junction box, route power supply wires through
approved conduit to either (a) double-pole, double-throw trans-
fer switch, or (b) approved isolation receptacle. Connecting to
a transfer switch or isolation receptacle must prevent vehicle
electrical circuits from being connected to two different power
supplies at the same time (such as generator and dockside
power).
• Exhaust piping must be large enough to prevent excessive back
pressure on the generator engine.
• Never tee the generator engine exhaust pipe into the vehicle
engine exhaust piping. This causes excessive back pressure on
the generator engine. Also, water from one engine can damage
the other engine.
• Conductors must be rated 221° F (105° C) or must be of a
larger conductor size.
• Plan exhaust system installation carefully. Comply with all appli-
2.6.3 GENERATOR AC CONNECTIONS
cable codes, standards and regulations.
Generator AC output leads T1 (red), T2 (white) and T3 (black)
come out of the generator as shown in Figure 2.13. Leads T1 (red)
and T3 (black) are “hot,” while T2 (white) is the grounded neutral
lead. There is also a green lead that connects to ground in the
junction box of the recreational vehicle.
2.6 ELECTRICAL CONNECTIONS
The following general rules apply to electrical connections in a
recreational vehicle:
• Qualified electricians who are familiar with applicable codes,
standards and regulations should install electrical wiring.
• The wiring should comply with codes, standards and regula-
tions. The National Electrical Code (NFPA 70), and state and
local codes apply.
Figure 2.13 – Generator AC Output Leads
• Switches and circuit breakers should be of a type approved for
use in recreational vehicles and must be mounted and installed
to prevent damage from road shock.
• Wiring must be of adequate size, have approved insulative
qualities and be properly supported.
• Conduit and wire openings into the generator compartment
(if used) must be vapor-sealed to prevent entry of flammable,
explosive or poisonous gases into the vehicle.
2.6.1 ELECTRICAL JUNCTION BOX
Install an approved, square electrical junction box with a blank
cover on the interior or exterior wall of the area planned for installa-
tion of the generator (NOT on the generator). Route the generator's
AC output leads into this junction box through approved flexible
conduit. This is the point of first termination for generator AC
output leads.
T3
T2
T1
AC Output Leads
Green
2.6.2 WIRING
(Ground)
• Wiring should be of stranded copper to reduce the chance that
vibration may cause breakage.
• Wire gauge size should be large enough to handle at least 115
percent of the installed generator's rated maximum current.
• If neutral conductors are used, they must be the same size as
other leg wires.
• Route power supply conductors from generator AC output leads
T1 (red), T2 (white), T3 (black) and the green ground wire
through approved flexible conduit to the electrical junction box
on the compartment wall.
• If flexible metal conduit is used between the generator and the
compartment junction box, the conduit end that terminates the
compartment junction box must be vapor-sealed. Flexible metal
conduit is NOT vapor tight along its entire length.
4500 Watts
Line T1 (black) to T2 (white) is protected by circuit breaker a
(CB1). Use this line to neutral connection to operate 120 volt,
single-phase, 60 Hz, AC loads.
5500 and 6500 Watts
Line T1 (red) to T2 (white) is protected against overload by a cir-
cuit breaker (CB1). Use this line-to-neutral connection separately
to operate 120-volt, single-phase, 60 Hertz, AC loads. Line T3
(black) to T2 (white) also is protected against overload by a circuit
breaker (CB2). Use this line-to-neutral connection separately to
operate similar loads. However, be sure the total unit load does not
exceed the maximum rating of the generator. The neutral line (T2,
white) on all units is a grounded neutral.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
2.7.1 RECOMMENDED BATTERY
Install a battery that meets the following requirements:
Do NOT connect electrical loads in excess
of any circuit breaker rating or problems will
• The battery must be a 12-volt, automotive type storage bat-
tery.
• For prevailing ambient temperatures above 32° F (0° C), use
a battery rated 70 amp-hours and capable of delivering 400
cold-cranking amperes.
• For prevailing ambient temperatures below 32° F (0° C), use
a battery rated 95 amp-hours and capable of delivering 400
cold-cranking amperes.
develop with circuit breaker tripping, which
causes a loss of AC output. Also, do NOT
exceed the generator's rated wattage capac-
ity. Add the watts or amperes of all lighting,
appliance, tool and motor loads the generator
will operate at one time. This total should be
less than the unit's rated wattage/amperage
capacity.
NOTE:
If the battery is to be used to power other vehicle accessories,
as well as start the generator, a battery with a larger capacity
may be needed.
2.6.4 CONDUIT
Route the connections between the generator and the junction box
through approved, flexible conduit. The following general rules
apply:
2.7.2 BATTERY CABLES
• Cut wiring to the required length and allow extra wire for junc-
tion box connections.
Using battery cables that are too long or too small in diameter
may cause a drop in voltage, which causes starting problems. For
the best cold weather starting, the voltage drop between battery
terminals and the generator connection point should not exceed
0.12 volts per 100 amperes of cranking current.
• Carefully prepare conduit ends to prevent sharp edges from
cutting through wiring insulation.
• Route conduit so it does not interfere with generator move-
ment.
• If using metallic conduit, vapor seal the end of the conduit
where it enters the junction box. Do this because flexible metal-
lic conduit is not vapor proof along its entire length.
These generators are rated at about 100 DC amperes of cranking
current.
Select battery cables based on (a) cable length and (b) prevail-
ing ambient temperatures. Generally, the longer the cable and the
colder the weather, the larger the cable size must be, as shown in
the chart.
2.6.5 ISOLATING DIFFERENT POWER SOURCES
Connections from the junction box must terminate in a double-
pole, double-throw transfer switch (Figure 2.14). An alternate
method for isolating different power sources is by using an isolat-
ing receptacle (Figure 2.15). Whichever method is used, be certain
that both power sources are NOT connected at the same time.
CABLE LENGTH in Feet (meters)
0 to 10 (0 to 3)
CABLE SIZE
2*
0
11 to 15 (3.4 to 4.5)
16 to 20 (4.5 to 6)
000
2.6.6 POWER SUPPLY CORD
The power supply cord must comply with all applicable codes,
standards and regulations. It must be large enough to handle the
full amperage to which it will be subjected.
*For warm weather, use No. 2 cable up to 20 feet.
NOTE:
Where a minimum of 1025 CCA (cold cranking amps) battery
current is available, up to 30 feet of AWG #2 battery cable is
permitted.
2.6.7 GROUND FAULT CIRCUIT
INTERRUPTERS
The National Electrical Code (NFPA 70, article 551) requires that
ground fault circuit interrupters (GFCIs) on all external and some
internal electrical receptacles be installed. Contact the manufac-
turer or dealer for recommendations.
2.7.3 BATTERY CABLE CONNECTIONS
1. Connect the battery cable from the battery post or terminal
indicated by a POSITIVE, POS or (+) to the lug on the starter
contactor (Figure 2.16).
NOTE:
2.7 BATTERY INSTALLATION
Check to be sure the battery cable boot for the starter cable has
been installed.
NOTE:
2. Connect the battery cable from the battery post indicated by a
NEGATIVE, NEG or (-) to the frame ground connection (Figure
2.16).
This generator is not equipped with an internal battery charger.
It is intended for use in systems where an external battery char-
ger is installed by the RV O.E.M. or an aftermarket installer.
3. Connect cables so the connectors are clean and tight.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 2.14 — Typical Transfer Switch Isolation Method
Figure 2.15 — Typical Installation With Isolation Receptacle
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Figure 2.16 – Connecting Battery Cables
Figure 2.17 – Remote Panel Plug-in Receptacle
Positive Cable
+
—
Battery
Chasis Ground
Negative Cable
2.7.4 BATTERY COMPARTMENT
Install the generator battery in its own, vented compartment. Place
the battery compartment away from any source of heat, sparks
or flame.
Provide ventilation openings in the battery compartment. The
minimum size of openings should be two (2) square inches at
the top of the compartment. Mount the battery on a strong, rigid
supporting structure, where leaks and spills of battery fluid will not
cause damage.
2.8 OPTIONAL ACCESSORIES
A plug-in receptacle (Figure 2.17) is provided on the generator set.
Use this receptacle to connect an optional remote-mounted start/
stop panel to the generator. Installation of such a panel will permit
starting and stopping the generator engine from any convenient
location inside the vehicle.
2.8.1 REMOTE PANEL MODELS
The remote panels mount a rocker type start/stop switch, a
“Generator Run” advisory lamp and an hourmeter. The hourmeter
should be used in conjunction with the maintenance operations
found in Part I of this manual.
WIRE NO.
WIRE COLOR
Black
FUNCTION
Ground
0
14
Blue
Engine Run Signal
12 VDC
712
17
Blue
Brown/White
Brown/Black
Start
18
Stop
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Post Installation
5. When all tests and adjustments at no-load are completed,
apply electrical loads and check for proper operation under
load (see "Testing Under Load"). Run the unit at least 30 min-
utes with loads applied.
6. Turn off all electrical loads by setting the generator’s main
circuit breakers to their “OFF” (or open) position.
7. Let the unit run at no-load for a few minutes to stabilize
internal engine/generator temperatures. Then, shut down the
engine.
3.1 POST INSTALLATION TESTS
The air-cooled generator set was factory tested and adjusted. It
should not be necessary to adjust the unit any further except under
special circumstances.
nDo not make any unnecessary adjustments.
Factory settings are correct for most applica-
tions. When making adjustments, however,
be careful to avoid overspeeding the engine.
NOTE:
The generator set was thoroughly tested and adjusted at the fac-
tory before shipping. No additional adjustment should be neces-
sary. Only qualified service technicians who have been trained
should perform adjustments outlined in this manual.
3.2 BEFORE INITIAL START-UP
Before starting, complete the following:
1. Check the engine crankcase oil level and, if necessary, fill to
the dipstick “FULL” mark (cross-hatched area) with the rec-
ommended oil. Do not fill above the FULL mark.
2. Check the fuel supply. Gas fuel lines must have been properly
purged and leak tested in accordance with applicable fuel
codes. All fuel shutoff valves in the fuel supply lines must be
open.
3.4 TESTING UNDER LOAD
Apply electrical loads equal to about 75 to 100 percent of the unit's
rated wattage/amperage capacity.
Let the unit run at least 30 minutes with load applied. During this
part of the test, check that the unit is not running excessively hot
and that adequate cooling airflow is available. Do not allow the unit
to overheat during prolonged operation.
3.3 INITIAL START
NOTE:
When certain that the unit has been properly installed and prepared
for use, start the engine as follows:
The generator engine is equipped with a high temperature
switch. The switch has normally open (N.O.) contacts. When the
engine temperature is too high, switch contacts close, and the
engine shuts down automatically.
1. Turn off all electrical loads. Do this by setting the generator’s
main circuit breakers to their “OFF” (or open) position.
2. Refer to Part I, “Starting the Generator”, for cranking and
starting instructions. The engine may require more cranking
for initial starting since the fuel lines have to be primed (use
of the primer switch will shorten this time).
THE MANUFACTURER RECOMMENDS THAT THE GENERATOR BE
TESTED FOR ADEQUATE COOLING.
3. Let the engine warm up for about five minutes to allow internal
temperatures to stabilize.
4. Carefully inspect the engine/generator for fuel, oil and exhaust
system leaks. Before proceeding to the next step, correct any
leakage immediately.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Post Installation
ELECTRICAL CONNECTIONS
3.5 INSTALLATION CHECKLIST
LOCATION AND SUPPORT
❑ Connections comply with local code requirements
and all National Electrical Codes.
❑ Generator is properly located.
❑ Generator is properly supported.
❑ Generator is properly restrained.
❑ Junction box is properly installed.
❑ Wiring meets all standards.
❑ All connections are correct.
❑ Conduit is properly installed and sealed.
❑ Generator is properly bonded to the vehicle.
GENERATOR COMPARTMENT
❑ Compartment construction is proper.
❑ Holes/Openings are vapor-sealed.
❑ Compartment size is correct.
❑ Compartment is vapor-sealed.
❑ Sound insulation is correct.
❑ Generator is always isolated from other power
sources.
BATTERY INSTALLATION
❑ Recommended battery is installed.
❑ Recommended cables are installed.
❑ Cables are clean and tight.
❑ Cables are connected properly.
❑ Proper ventilation is provided.
❑ Floor cutouts are properly completed.
COOLING AND VENTILATING AIR
❑ Airflow is adequate.
❑ Air inlet opening is correct.
❑ Compensate for restrictions.
❑ Check that installation has been tested.
❑ Terminals are coated with anti-corrosion grease, and
terminal covers are positioned.
OPTIONAL ACCESSORIES
❑ Check that remote start/stop panels (if used) are
GASOLINE FUEL SYSTEM
❑ Fuel tank complies with all applicable codes.
installed properly.
❑ Check that hourmeter kit (if used) is installed
❑ Fuel system is properly installed and checked for
properly.
leaks.
❑ Check that any other options and accessories (if
used) are installed properly.
EXHAUST SYSTEM
❑ Exhaust system complies with all applicable codes.
POST INSTALLATION TESTS
❑ Check that all tests are completed properly.
❑ Exhaust system is properly and safely installed.
DATE OF INSTALLATION_________________________________________________
NAME OF INSTALLER ____________________________________________________
SIGNATURE OF INSTALLER _____________________________________________
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
4.1 TROUBLESHOOTING GUIDE
Problem
Cause
Correction
Engine won’t crank.
1. 7.5 amp fuse blown.
1. Replace blown fuse.
2. Loose, or corroded or defective
battery cable(s).
2. Tighten, clean or replace,
as necessary.
3. Battery is discharged or defective.
4. Defective Start/Stop switch.
5. Defective starter contactor.
6. Defective starter motor.
7. Defective Engine Control Board
3. Recharge or replace battery.
4. Replace switch.
5. Replace starter contactor.
6. Replace starter motor.
7. Contact an authorized service dealer.
Engine cranks, won't start.
1. Out of fuel.
1. Refill fuel tank.
2. Fuel pump not operating.
3. Automatic choke not operating properly.
4. Engine is flooded.
5. Fuel filter is clogged.
6. Engine spark plugs defective.
7. Bad ignition magneto on engine.
8. Bad carburetor.
2. Repair or replace pump.
3. Repair, replace or adjust.
4. Wait 5-10 minutes; try again.
5. Replace filter if clogged.
6. Clean, regap or replace as needed.
7. Replace if defective.
8. Adjust, repair or replace.
9. Clean or replace as needed.
9. Dirty air cleaner.
Engine starts hard, runs rough.
Engine starts, then shuts down.
1. Dirty engine air cleaner.
2. Automatic choke is sticking.
3. Defective spark plugs.
1. Clean or replace as needed.
2. Free choke linkage as needed.
3. Clean, regap or replace.
4. Replace it if defective.
4. Defective ignition magneto.
1. Engine oil level is low.
2. Bad low oil pressure switch.
3. Defective high temp switch.
4. Water in fuel.
1. Add oil as needed.
2. Replace, if bad.
3. Replace, if bad.
4. Drain fuel tank and refill.
5. Defective remote harness.
5. Disconnect remote harness. Contact
authorised service facility.
No AC output voltage.
1. Main breaker(s) open.
2. Transfer switch (if so equipped) is
set to wrong position.
1. Close main breaker(s).
2. Reset transfer switch.
3. Failure in vehicle electrical system.
4. Generator component failure.
3. See vehicle manual.
4. Contact an authorized service facility.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Data
Wiring Diagram Drawing No. 0G4221-C
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring Diagram Drawing No. 0G4221-C
Electrical Data
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Data
Wiring Diagram Drawing No. 0H3633-A
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring Diagram Drawing No. 0H3633-A
Electrical Data
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views & Parts Lists
Enclosure Drawing No. 0G3881-F
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Enclosure Drawing No. 0G3881-F
Exploded Views & Parts Lists
ITEM
PART NO.
QTY.
DESCRIPTION
1
2
3
4
5
6
7
8
9
0G3396
0C5644
0G5236
0D3700
0G3401
0G4077
0G4433
0G3377
0G3431
0F9199
0G3430
0G3402
090388
0G3422
0G5237
0G3399
0D3472
0G4933
0G5238
0G3397
0G4391
0G5239
0G3392
0G3754
0G3398
0G3912
0G3400
0G5240
0G5242
0G5241
045756
0G5755
0G5761
022473
022097
022287
0G3429
1
2
1
23
1
1
1
1
1
1
1
1
13
1
1
1
1
18
1
1
1
1
1
1
1
1
1
1
1
2
9
1
1
1
1
1
1
ENCLOSURE DOOR
SLIDE LATCH, FLUSH
FOAM ENCLOSURE DOOR
NUT FLANGE M6-1.0 NYLOK
DUCT, AIR IN DOOR
GROMMET, OIL FILTER
U CHANNEL 1/8”
TRAY, 530 RV
GASKET AIR IN BOTTOM DUCT
PLUG PLASTIC 1.093-1.125
GASKET AIR IN TOP DUCT
DUCT AIR IN ROOF
SCREW HHTT M6-1.0X12 ZINC
TOP DIVIDER PANEL
FOAM, SIDE ENCLOSURE
ENCLOSURE SIDE / BACK
GROMMET OVAL 31.75X50.8
SCREW SWT 1/4-20X5/8 W/W
FOAM BACK ENCLOSURE ALT SIDE
ENCLOSURE ROOF
ENCLOSURE, BACK PANEL 530 RV
FOAM BACK PANEL ENCLOSURE
UPPER BLOWER HOUSING
UPPER BLOWER HOUSING GASKET
EXHAUST DIVIDER PANEL
MUFFLER HOLD DOWN BRACKET
ENCLOSURE EXHAUST SIDE PANEL
FBR GLASS, ENCLOSURE MFLR BACK
FOAM EXHAUST END ENCL FRONT
FBR GLASS, ENCLOSURE MFLR SIDE
SCREW HHTT M6-1.0X10 ZYC
BUMPER
10
11
12
13
14
15
16
17
18
23
24
25
26
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
STAND OFF
WASHER, FLAT 1/4”
WASHER, LOCK 1/4”
SCREW HHC 1/4-20 X 3/4” G5
GASKET, SCROLL DUCT
SHEET METAL PAINT/MATERIAL CODE LEGEND
The following exploded views contain part numbers of various sheet metal components. Only the base part number is listed. When ordering sheet metal, the
correct color and material information must be included as a suffix at the end of the part number as shown below.
Material
S = Steel
Color
G = Gray
B = Black
Example:
Desc.
Roof
Upper Blower Hsg.
Part No.
0G3397
0G3392
Material
S = Steel
S = Steel
Color
G = Gray
B = Black
Order As"
0G33970ST08
0G33920ST03
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views & Parts Lists
Control Panel Drawing No. 0H3635-C
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Panel Drawing No. 0H3635-C
Exploded Views & Parts Lists
ITEM PART NO. QTY. DESCRIPTION
ITEM PART NO. QTY. DESCRIPTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
045757
0F5458
023484S
0G9081*
049813
022473
0A1658
0G3380
0F9176
0G3662A
028414
0D3700
0G5225
028916
087769
025965
022097
0G5318
0H3634
0G4602
0C7968
022237
0A4456
0C7423
022259
022129
022145
0E0593
0D8502
0G5233
0G3825
0G3689
092036
0A9611
032300
0G4215
1
2
1
1
1
2
1
1
SCREW HHC M6-1.0 X 25 G8.8
SCREW PLASTITE HI-LOW #10X3/8
BUSHING SNAP SB-1093-937
WIRE HARNESS C/PNL FRAME
NUT HEX M6 X 1.0 G8 YEL CHR
WASHER FLAT 1/4-M6 ZINC
36
37
38
39
40
41
42
43
44
45
46
47
48
49
082025
0F9719
0G3977
0G3530
075476
090987
0C2174
031879
0D9784
075235
074908
075210A
0E6480
090144 (5500W)
090145 (6500W)
090145
4
1
1
1
2
2
1
2
2
4
4
1
2
1
1
1
NUT HEX LOCK M5-0.8 NYINS ZINC
ASSY PCB VREG AIR COOLED 2006
ASSY PCB RV CONTROLLER
C/PNL FRAME RV
SCREW PPHM M4-0.7 X 16
SCREW PPHM M3-0.5 X 12
RELAY 12V 25A SPST
WASHER LOCK SPECIAL 1/4"
FUEL PUMP MOUNTING BRACKET
WASHER FLAT #4 ZINC
28.75” HOSE,1/4" SAE30R7
NUT HEX LOCK M3-0.5 NY INS
SCREW HHC M5-0.8 X 30 G8.8
SCREW HHTT M5-0.8 X 10 BP
BLOCK 1 POSITION, 4 TAB
NUT HEX LOCK M4-0.7 NY INS
CIRCT BRK 20X1 MAG 10-32 CARL
CIRCT BRK 30X1 MAG 10-32 CARL
CIRCT BRK 30X1 MAG 10-32 CARL
(4500W, 5500W, 6500W)
EARTH STRAP
NYLON SPACER .26 X 1.00 X 1.73
PLUG, PLASTIC .75 (5410-1/5412-
1/5414-1 ONLY)
BARBED EL 90 ¼ NPT X 5/16
(5751/5752/5753 ONLY)
BULKHEAD ADAPTER
(5751/5752/5753 ONLY)
BUSHING REDUCER HEX ¼ TO 1/8 NPT
(5751/5752/5753 ONLY)
NIPPLE PIPE 1/8 NPT X 1 ½
(5751/5752/5753 ONLY)
SOLENOID 12 VDC (5751/5752/5753
ONLY)
BARBED EL 90 1/8 NPT X ¼
(5751/5752/5753 ONLY)
1
1
5
1
1
1
1
2
1
1
1
3
2
1
1
2
2
1
1
1
2
1
1
4
1
1
1
CLAMP HOSE BAND .50
BARBED STR 1/8NPT X 1/4
NUT FLANGE M6-1.0 NYLOK
FUEL PUMP
ELBOW 90D STREET 1/8 BRASS
FILTER FUEL 1/8P-1/4H
SCREW HHC 1/4-20 X 2-1/4” G5
WASHER LOCK M6-1/4
50
AC HARNESS 530RV (5500 + 6500W)
AC HARNESS 530RV EVAP (4500W)
GROMMET, DOUBLE SLIT
NUT HEX JAM 3/8-16 BRASS
WASHER LOCK 3/8
WASHER LOCK SPECIAL 3/8
STUD 3/8-16 X 2-1/4 BRASS
NUT HEX 5/16-18 STEEL
WASHER LOCK M8-5/16
WASHER FLAT 5/16-M8 ZINC
STUD, 1/4-20 TO 5/16-18
NEUTRAL CONNECTOR UL
SCREW PPHTF #8-18 X 1/2 AB
CONTROL PANEL COVER
C/PNL FACE
51
52
53
0C2417A
0G5986
061669
1
1
1
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
54
55
56
57
58
59
059502
069598
035579
035483
0G0247
028740
1
1
1
1
1
1
SCREW PPHM #6-32 X 1/4 SEMS
FUSE 7.5AXBK/AGC7.5NX
HOLDER FUSE
*HARNESS NOT SHOWN
SWITCH RKRSPDT(ON)OFF(ON)ILLUM
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views & Parts Lists
Base & Pulley Drawing No. 0G7720-B
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Base & Pulley Drawing No. 0G7720-B
Exploded Views & Parts Lists
ITEM
PART NO.
QTY.
DESCRIPTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
0G3377
081105
022259
022129
022145
0G5217
0G3748
046526
022131
0G3384
0C7758A
0C1751
0C2824
022473
022097
043116
0G3383
0G4350
0G3379
0C3062
0G4429
0G3391
0G3742
0G7670
0E0588
0G4702
029451
0G3426
0G5676
0G5676A
0G4692
022473
0A2110
0G3410
0G3393
0G7887
025145
0C8565
056892
089680
094670
0G3394
0G3395
056893
023897
0G4260
0E9369
1
2
8
12
13
2
1
2
2
1
4
1
11
7
7
7
1
1
2
2
1
1
1
1
1
2
1.5ft
1
1
1
1
3
3
5
1
1
TRAY, 530 RV
NUT FLANGE 5/16-18 LOCK
NUT HEX 5/16-18 STEEL
WASHER LOCK M8-5/16
WASHER FLAT 5/16-M8 ZINC
SCREW HHC 3/8-24 X 1-1/2 G8
BELT V-RIBBED 4L X 43.75" LG
WASHER LOCK M10
WASHER FLAT 3/8-M10 ZINC
ALTERNATOR PULLEY
VIB MNT 1.5X1.38X5/16-18 DR 45
FAN 7" DIA (NYLON)
SCREW HHTR #10-32 X 9/16
WASHER FLAT 1/4-M6 ZINC
WASHER LOCK M6-1/4
SCREW HHC M6-1.0 X 12 G8.8
ENGINE PULLEY
FAN ENGINE PULLEY RV
BRACKET MUFFLER SUPPORT
BOLT CARR 5/16-18 X 1
EDGE TRIM W/ 3/4" HOLLOW CYL.
BLOWER HOUSING WALL
GASKET, LOWER BLOWER HOUSING
FRAME GT530 RV MOUNTING
SPACER, SAFETY BOLT .375 I.D.
SCREW HHC 5/16-18 X 3 SPC
TAPE ELEC UL FOAM 1/8 X 1/2
DUCT AIR OUT
GASKET,AIR OUT DUCT
GASKET, AIR OUT DUCT OPPOSITE SIDE
SCREEN, BOTTOM AIR OUT
WASHER FLAT 1/4-M6 ZINC
SCREW SWAGE 1/4-20 X 1/2 ZYC
ISOLATION SPRING
30
31
32
33
34
MUFFLER, 530 RV
MUFFLER. 530 RV (MODELS: 5410-1 / 5412-1 / 5414-1 ONLY)
BOLT U 5/16-18 X 1.25 W/SADDLE
SCREW SHC M8-1.25 X 18 G8.8
SCREW CRIMPTITE 10-24 X 3/8
SCREEN SPARK ARRESTOR
CLAMP EXHAUST
EXHAUST FLEX
EXHAUST MANIFOLD
SCREW CRIMPTITE 10-24 X 1/2
WASHER FLAT #10 ZINC
GASKET, EXH BASE, 530 RV
GASKET, EXHAUST GT530
35
36
37
38
39
40
41
42
43
44
45
1
4
1
1
2
1
1
6
6
2
2
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views & Parts Lists
Engine Accessories Drawing No. 0G7718-K
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Engine Accessories Drawing No. 0G7718-K
Exploded Views & Parts Lists
ITEM PART NO. QTY. DESCRIPTION
ITEM PART NO. QTY. DESCRIPTION
1
3
4
5
6
7
8
9
0G7670
0G3404
0E9507
023484S
056893
0G4129
0C8563
0G3405
0G4985A
0E9525A
0E4997
067198N
067890
0G3911
0G4130
082774
0G3454
022131
0G5221A
0G5221B
0G6432
0E9319
0E9333
040976
0E9471
0E9383D
0G9640
0G3890
0G4378
040173
0G3406
0G3455
0G3413
078601
0G5057
0E9511B
0G3414
0G3408
045756
1
1
8
1
14
1
12
1
1
1
1
1
1
1
1
1
1
3
1
1
4
2
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
FRAME
50
51
52
53
54
55
56
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
80
81
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
0G3386
0A2311
070185B
0D9235
0G4793
043182
0C1085
0G4576
0A2110
0G3407
0G3915
0G3840
0G3839
0E9368
0G7671
0G3389
0A7094
0D8590
0D8591
0G3984
043146
022097
0D6342
0D9784
0G4016
043116
0F1177
077091
075763A
0742600173
022473
061906
049813
056892
0E9323
022129
0A4456
022746
055934M
0G6725
0G6729
078643C
096290A
046526
0G9148
0G7757A
1
2
1
1
1
2
2
1
1
1
1
1
1
2
1
1
2
1
1
1
2
6
1
1
1
2
1
1
1
1
2
2
2
2
1
2
1
4
1
1
1
2
2
3
1
1
OIL FILTER SUPPORT
SCREW SWAGE 1/4-20 X 1
OIL FILTER
OIL PRESSURE SWITCH 5 PSI
SWITCH, THERMAL 270F
WASHER, LOCK M3
SCREW PPHM M3-0.5 X 8
BRACKET, OIL CHECK TUBE
SCREW SWAGE 1/4-20 X 1/2
WRAPPER ENGINE VALLEY
WRAPPER UPPER VALLEY
WRAPPER INNER CYLINDER #2
WRAPPER INNER CYLINDER #1
SPARKPLUG
ENGINE WRAPPER, STARTER SIDE
SCREW HHFC M8-1.25 X 14
SNAP BUSHING
SCREW CRIMPTITE 10-24 X 1/2
SHIELD WRAPPER, CYLINDER #1
SCREW HHFC M6-1.0 X 12 G8.8
ENGINE WRAPPER, BACK
BACKPLATE
ASSY, FLYWHEEL & RING GEAR 29D
ASSY, GROUND WIRE CONNECTOR
WASHER,BELV-20 X 2.2
NUT HEX M20-1.5 G8
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
40
41
BLOWER HOUSING
SHIELD WRAPPER, CYLINDER #2
KEY, WOODRUFF 4 X 19D
BREATHER HOSE
WASHER FLAT 3/8 – M10 ZINC
IGNITION COIL CYLINDER #1
IGNITION COIL CYLINDER #2
SCREW HHFC M6-1.0 X 25 SEMS
GASKET, INTAKE
OIL LINE OUT
OIL LINE IN
SCREW PPHM #4-40 X 1/4
ASSEMBLY, BI-METAL/HEATER
CHOKE SOLENOID
CONTROLLER ASSEMBLY
SCREW HHC M6-1.0 X 10 G8.8
WASHER LOCK M6-1/4
BALL STUD, 10 MM
NUT HEX LOCK M3-0.5
BRACKET, CONTROLLER SUPPORT
SCREW HHC M6-1.0 X 12 G8.8
ASSY, GROUNDING WIRE W/O DIODES
COTTER PIN
INTAKE MANIFOLD
SCREW SHC M8-1.25 X 20 G12.9
GASKET, MANIFOLD TO CARB/MIXER
CARBURETOR
ROD, CHOKE CONTROL
ASSY GOVERNOR ROD
GASKET, AIRBOX/CARB
CLAMP, HOSE WORM GEAR
WRAPPER, ENGINE OIL ADAPTOR
SNORKEL, AIR BOX
AIRBOX BASE
AIR FILTER
AIRBOX SEAL
AIRBOX QUARTER KNOB
AIRBOX COVER
OIL DRAIN LINE
SCREW HHTT M6-1.0 X 10 YELLOW
CHROME
CLAMP, VINYL 9.5 O.D.
3/4 NPT TO 3/8 O.D. FLARE
ASSY, CAP AND DIPSTICK
OIL DRAIN/DIPSTICK TUBE
90 DEGREE ELBOW 3/8 NPT X 3/8
BARBED
BOOT, BATT. CABLE
WIRE ASSY. BATT. POS.
WASHER, FLAT 1/4-M6
SCREW HHC M8-1.25 X 85
NUT M6-1.0
SCREW CRIMPTITE 10-24 X 3/8
START MOTOR
WASHER, LOCK M8-5/16
WASHER, LOCK SPECIAL 3/8
SCREW HHC 3/8-16 X 1-3/4 G5
CLAMP VINYL .75 X .343
INSULATOR
GASKET, MANIFOLD TO CARB/MIXER
BOLT,CARB MOUNT M6-1.0 X 95
STUD M6-1.0 X 100
42
43
44
45
46
0E0998
0G3432
0E0393A
0E0361B
043790
1
2
1
1
1
WASHER LOCK M10
PLUG, RUBBER (4703, 5, 6 & 7)
HOSE MOLDED EVAP. PORT (05751,
05752 & 05753)
SCREW, BHSC M6-1 X 8
SCREW BHSC M6-1 X 8MM BLACK
47
48
49
0G3662B
0F0452B
0G4426
2
8”
1
HOSE OETIKER CLAMP
HOSE, 3/8” I.D.
ASSY, OIL DRAIN FITTING
99
100
0H4269
0G9062
1
1
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views & Parts Lists
530 RV Engine Drawing No. 0G7719-B
48
Download from Www.Somanuals.com. All Manuals Search And Download.
530 RV Engine Drawing No. 0G7719-B
Exploded Views & Parts Lists
ITEM
PART NO.
QTY.
DESCRIPTION
1
2
3
4
5
6
7
8
9
0E3812
0D4788
073144
0G7260A
078699B
0A5776
0E9482
0C5315A
0C5314A
0E9379
0E9382
0G0919
0E3372A
0E9345
076390
0G4379
0G4331
076389
0G1054
0G1063G
093064
0E9334F
080318
0E9352
0E9368
077168
084186
088156
0C4390
0C3733
0C3592
077161
077160
076307
0E9353A
0E9304
0C3591
0C3590
0E9351
0G5728
0E9455E
083235
0G7679
0E9350
0E9334G
0E9305
0E9429C
0E9366
0G5670
0C8566
0C5943
0G0273
0G5896
0G0275
0G0276
2
1
9
1
6
1
1
1
1
1
1
3
1
1
4
2
2
2
2
1
1
1
8
2
2
12
4
2
4
4
8
4
4
4
2
1
2
2
2
1
4
4
1
1
1
1
1
1
1
1
1
1
1
1
1
SEAL D 35 X 48.2
3/8” SQUARE HEAD PLUG
SCREW HHFC M8 – 1.25 X 45
GEAR COVER
SLEEVE DOWEL PIN
11/32 DIAMETER PRESSURE RELIEF BALL
OIL PRESSURE SPRING
GEAROTOR, OUTER
GEAROTOR, INNER
SCREEN, OIL PICK-UP
COVER, GEROTOR
SCREW, HHFCS M6-1.0 x 12
BREATHER SEPARATOR
GEAR, GEAROTOR
RETAINER RING
PISTON RING SET
PISTON
PISTON PIN
CONNECTING ROD ASSEMBLY
CRANKSHAFT
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
OIL FILL CAP
COVER ROCKER W/FILL
SCREW HHFC M6-1.0 X 25
GASKET, VALVE COVER
SPARK PLUG
SCREW HHC M8-1.25 X 56
WASHER, VALVE SPRING
SEAL, VALVE STEM
VALVE SPRING
VALVE RETAINER
KEEPER, VALVE SPRING
STUD, ROCKER ARM
ROCKER ARM
JAM NUT, ROCKER ARM
PUSH ROD GUIDE PLATE
CYLINDER HEAD CYL. 1
INTAKE VALVE
EXHAUST VALVE
GASKET CYLINDER HEAD
SCREEN
PUSHROD
TAPPET
CAM SHAFT & GEAR
GASKET, CRANKCASE
COVER ROCKER
CYLINDER HEAD CYL 2
CRANKCASE
GASKET, BREATHER ASSEMBLY
BREATHER ASSY
SCREW HHFC M6-1.0 X 20
SEAL, OIL PASSAGE
GASKET KIT
BREATHER KIT
KIT HEAD ASSY CYLINDER #1
KIT HEAD ASSY CYLINDER #2
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Exploded Views & Parts Lists
Rotor & Stator Drawing No. 0G3953-B
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Rotor & Stator Drawing No. 0G3953-B
Exploded Views & Parts Lists
ITEM
PART NO.
QTY.
DESCRIPTION
1
2
3
4
5
6
7
9
10
11
12
13
052858
075237
075242
0C1878
073146
052203
022145
0G3913
029459
075215
0G3382
0G3877H
0G3878H
0G3879H
0G3893H
0G3894H
0G3895H
0G3381
022129
045771
066386
066849
0G3542
022131
042633
022237
6
4
4
2
4
2
6
4
2
2
1
1
1
1
1
1
1
1
4
4
1
2
1
1
1
1
NUT TOP LOCK FL M8-1.25
WASHER, SPRNG CENTER
SPRING, GEN. MOUNT
SUPPORT, SLIDE
SLIDE, NYLON
SCREW HHC M8-1.25 X 70 G8.8
WASHER FLAT 5/16-M8 ZINC
STUD, 530 RV STATOR
TENSION SPRING
WASHER, SPRING CENTR
LOWER BEARING CARRIER
RTR 200 4.5AD1 RV
RTR 200 5.5AD1 RV
RTR 200 6.5AD1 RV
STR 200-4.5AD1 RV
STR 200-5.5AD1 RV
STR 200-6.5AD1 RV
UPPER BEARING CARRIER
WASHER LOCK M8-5/16
NUT HEX M8-1.25 G8 CLEAR ZINC
ASSEMBLY, BRUSH HOLDER
SCREW HHTT M5-0.8 X 16
FAN UPPER ALTERNATOR
WASHER FLAT 3/8-M10 ZINC
SCREW HHC 3/8-24 X 1 G5
WASHER LOCK 3/8
14
15
16
17
18
19
20
21
22
23
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
CALIFORNIA AND FEDERAL EMISSION CONTROL WARRANTY STATEMENT
YOUR WARRANTY RIGHTS AND OBLIGATIONS
The California Air Resources Board (CARB) and the United States Environmental Protection Agency (EPA), together with Generac Power
Systems, Inc. (Generac), are pleased to explain the Emission Control System warranty on your new 2008 and later generator. New equip-
ment that use small spark-ignited engines must be designed, built, and equipped to meet stringent anti-smog standards for the state of
California and the federal government. Generac will warrant the emission control system on your generator for the period of time listed below
provided there has been no abuse, neglect, unapproved modification or improper maintenance of your equipment.
Your emission control system may include parts such as the: carburetor, ignition system, fuel system catalytic converter, and other associ-
ated emission-related components (if equipped).
MANUFACTURER’S WARRANTY COVERAGE:
This emission control system is warranted for two years. If, during such warranty period, any emission-related part on your equipment is
found to be defective in materials or workmanship, repairs or replacement will be performed by a Generac Authorized Warranty Service
Dealer.
OWNER'S WARRANTY RESPONSIBILITIES:
As the generator owner, you are responsible for the completion of all required maintenance as listed in your factory supplied Owner's
Manual. For warranty purposes, Generac recommends that you retain all receipts covering maintenance on your generator, but Generac
cannot deny warranty solely due to the lack of receipts.
As the generator owner, you should be aware that Generac may deny any and/or all warranty coverage or responsibility if your generator,
or a part/component thereof, has failed due to abuse, neglect, improper maintenance or unapproved modifications, or the use of counterfeit
and/or "grey market" parts not made, supplied or approved by Generac.
You are responsible for contacting a Generac Authorized Warranty Dealer as soon as a problem occurs. The warranty repairs should be
completed in a reasonable amount of time, not to exceed 30 days.
Warranty service can be arranged by contacting either your selling dealer or a Generac Authorized Warranty Service Dealer. To locate the
Generac Authorized Warranty Service Dealer nearest you, call our toll free number:
1-800-333-1322
IMPORTANT NOTE: This warranty statement explains your rights and obligations under the Emission Control System Warranty (ECS
Warranty), which is provided to you by Generac pursuant to California and federal law. See also the "Generac Limited Warranties for Generac
Power Systems, Inc.," which is enclosed herewith on a separate sheet, also provided to you by Generac. Note that this warranty shall not
apply to any incidental, consequential or indirect damages caused by defects in materials or workmanship or any delay in repair or replace-
ment of the defective part(s). This warranty is in place of all other warranties, expressed or implied. Specifically, Generac makes no other
warranties as to the merchantability or fitness for a particular purpose. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.
The ECS Warranty applies only to the emission control system of your new equipment. If there is any conflict in terms between the ECS
Warranty and the Generac Warranty, the Generac Warranty shall apply. Both the ECS Warranty and the Generac Warranty describe important
rights and obligations with respect to your new engine.
Warranty service can be performed only by a Generac Authorized Warranty Service Facility. When requesting warranty service, evidence
must be presented showing the date of the sale to the original purchaser/owner.
If you have any questions regarding your warranty rights and responsibilities, you should contact Generac at the following address:
ATTENTION WARRANTY DEPARTMENT
GENERAC POWER SYSTEMS, INC.
P.O. BOX 297 • WHITEWATER, WI 53190
Part 1
Part No. 0H1912 Rev. A 05/09
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
EMISSION CONTROL SYSTEM WARRANTY
Emission Control System Warranty (ECS warranty) for equipment using small spark-ignited engines:
(a) Applicability: This warranty shall apply to equipment that uses small off-road engines. The ECS Warranty period shall begin on the date the new equip-
ment is purchased by/delivered to its original, end-use purchaser/owner and shall continue for 24 consecutive months thereafter.
(b) General Emissions Warranty Coverage: Generac warrants to the original, end-use purchaser/owner of the new engine or equipment and to each sub-
sequent purchaser/owner that the ECS when installed was:
(1) Designed, built and equipped so as to conform with all applicable regulations; and
(2) Free from defects in materials and workmanship which cause the failure of a warranted part at any time during the ECS Warranty Period.
(c) The warranty on emissions-related parts will be interpreted as follows:
(1) Any warranted part that is not scheduled for replacement as required maintenance in the Owner's Manual shall be warranted for the ECS Warranty
Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by Generac according to Subsection (4) below. Any
such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
(2) Any warranted part that is scheduled only for regular inspection as specified in the Owner's Manual shall be warranted for the ECS Warranty
Period. A statement in the Owner’s Manual to the effect of "repair or replace as necessary" shall not reduce the ECS Warranty Period. Any such
part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
(3) Any warranted part that is scheduled for replacement as required maintenance in the Owner's Manual shall be warranted for the period of time prior
to first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by
Generac according to Subsection (4) below. Any such emissions-related part repaired or replaced under the ECS warranty shall be warranted for
the remainder of the period prior to the first scheduled replacement point for that part.
(4) Repair or replacement of any warranted, emissions-related part under this ECS Warranty shall be performed at no charge to the owner at a
Generac Authorized Warranty Service Facility.
(5) Notwithstanding the provisions of subsection (4) above, warranty services or repairs must be provided at Generac Authorized Service Facilities.
(6) When the engine is inspected by a Generac Authorized Warranty Service Facility, the purchaser/owner shall not be held responsible for diagnostic
costs if the repair is deemed warrantable.
(7) Throughout the ECS Warranty Period, Generac shall maintain a supply of warranted emission-related parts sufficient to meet the expected demand
for such parts.
(8) Any Generac authorized and approved emission-related replacement parts may be used in the performance of any ECS warranty maintenance or
repairs and will be provided without charge to the purchaser/owner. Such use shall not reduce Generac ECS Warranty obligations.
(9) Unapproved, add-on, modified, counterfeit and/or "grey market" parts may not be used to modify or repair a Generac engine. Such use voids this
ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. Generac shall not be held liable hereunder for failures of any
warranted parts of Generac equipment caused by the use of such an unapproved, add-on, modified, counterfeit and/or "grey market" part.
EMISSION RELATED PARTS MAY INCLUDE THE FOLLOWING (IF EQUIPPED):
1) FUEL METERING SYSTEM
A. CARBURETOR AND INTERNAL PARTS
B. PRESSURE REGULATOR
2) AIR INDUCTION SYSTEM
A. INTAKE MANIFOLD
4) AIR INJECTION SYSTEM
A. PULSE AIR VALVE
5) EXHAUST SYSTEM
A. CATALYST
B. THERMAL REACTOR
C. EXHAUST MANIFOLD
B. AIR FILTER
3) IGNITION SYSTEM
A. SPARK PLUGS
B. IGNITION COILS / MODULE
Part 2
Part No. 0H1912 Rev. A 05/09
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
GENERAC POWER SYSTEMS’ THREE-YEAR LIMITED WARRANTY
FOR GENERAC RECREATIONAL VEHICLE GENERATORS
NOTE: ALL UNITS MUST BE INSTALLED BY GENERAC POWER SYSTEMS AUTHORIZED SERVICE FACILITIES. For a period of 3
(three) years of operation from the date of original sale, Generac Power Systems, Inc. (Generac) will, at its option, repair or replace any part
which, upon examination, inspection and testing by Generac or a Generac Authorized Warranty Service Facility, is found to be defective
under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to
be defective must be returned to and examined by the nearest Generac Authorized Warranty Service Facility. All transportation costs under
the warranty, including return to the factory, are to be borne and prepaid by the purchaser/owner. This warranty applies only to Generac
generators sold and rated for “Recreational Vehicle” (RV) applications, as Generac has defined Recreational Vehicle generator applications.
The factory recommends exercising the unit one half-hour every month.
WARRANTY SCHEDULE – COMMERCIAL APPLICATIONS
YEAR ONE – 100% (one hundred percent) coverage on part(s), labor, removal and reinstallation listed:
• Engine – All components
• Alternator – All components
WARRANTY SCHEDULE – CONSUMER/PERSONAL APPLICATIONS
YEARS ONE AND TWO – 100% (one hundred percent) coverage on part(s), labor, removal and reinstallation listed:
• Engine – All components
• Alternator – All components
YEAR THREE – 100% (one hundred percent) only on selected part(s) and labor listed [Any labor and part(s) not listed, and removal and
reinstallation are the owner’s responsibility]:
• Rotor, Stator, Computer Control Board (part numbers 0A6060 and 0A3369) and inverter, (if applicable with regard to the generator) Cylinder
Block, Cylinder Head, Crankshaft, Piston(s), Valve, Valve Lifter(s), Intake and Exhaust Manifolds
Generac RV generators manufactured prior to December 31, 1997, DO NOT have a transferable warranty. Generac RV generators manu-
factured after January 1, 1998, have a transferable warranty to the second owner ONLY for the remainder of the three-year limited warranty.
Proof-of-purchase is required and must be presented to a Generac Authorized Warranty Service Facility prior to the performance of any
warranty service.
All warranty expense allowances are subject to the conditions defined in Guardian’s Warranty Policies and Procedures Guide.
THIS WARRANTY SHALL NOT APPLY TO THE FOLLOWING:
• Generac Guardian generators that utilize non-Generac replacement parts.
• Costs of normal maintenance, adjustments, installation and start-up.
• Repairs or diagnostics performed by individuals other than Guardian/Generac authorized dealers not authorized in writing by Generac
Power Systems.
• Failures caused by any contaminated fuels, oils, coolants or lack of proper fluid amounts.
• Failures due, but not limited, to normal wear and tear, accident, misuse, abuse, negligence or improper installation. As with all mechani-
cal devices, the Generac engines need periodic part(s) service and replacement to perform well. This warranty will not cover repair when
normal use has exhausted the life of a part(s) or engine.
• Failures caused by any external cause or act of God, such as collision, theft, vandalism, riot or wars, nuclear holocaust, fire, freezing,
lightning, earthquake, windstorm, hail, volcanic eruption, water or flood, tornado or hurricane.
• Damage related to rodent and/or insect infestation.
• Products that are modified or altered in a manner not authorized by Generac in writing.
• Any incidental, consequential or indirect damages caused by defects in materials or workmanship, or any delay in repair or replacement
of the defective part(s).
• Failure due to misapplication.
• Telephone, cellular phone, facsimile, internet access or other communication expenses.
• Living or travel expenses of person(s) performing service, except as specifically included within the terms of a specific unit warranty
period.
• Expenses related to "customer instruction" or troubleshooting where no manufacturing defect is found.
• Rental equipment used while warranty repairs are being performed.
• Overnight freight costs for replacement part(s).
• Overtime labor.
• Starting batteries, fuses, light bulbs and engine fluids.
THIS WARRANTY IS IN PLACE OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. SPECIFICALLY, GENERAC MAKES NO OTHER WARRANTIES
AS TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.
GENERAC'S ONLY LIABILITY SHALL BE THE REPAIR OR REPLACEMENT OF PART(S) AS STATED ABOVE. IN NO EVENT SHALL GENERAC BE
LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, EVEN IF SUCH DAMAGES ARE A DIRECT RESULT OF GENERAC'S NEGLIGENCE.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights. You also have other rights from state to state.
GENERAC® POWER SYSTEMS, INC.
P.O. BOX 297
•
WHITEWATER, WI 53190
Rev. A 06.09
Part No. 0H3467
Revision B (04/15/10)
Printed in U.S.A.