Operating Manual
Monitoring Speaker
Download from Www.Somanuals.com. All Manuals Search And Download.
Speaker Mounting
Position
Treble tilt
Bass tilt
Bass roll-off
Flat anechoic response
None
None
None
-2 dB
None
None
Free standing in a
damped room
Free standing in a
reverberant room
None
None
-4 dB
-4 dB
-2 dB
-4 dB
Near field or console
bridge
Table 1. Suggested tone control settings in some typical situations
Cable
Screen
RCA
XLR
(Source)
(Speaker)
Figure 2. Location of the acoustic axis
Figure 1. Amplifier panel layout of the 1030A
Figure 3. RCA to XLR cable
gives an SPL of 100 dB @1m with -6 dBu
input level.
expose the unit to water or moisture. Do
not place any objects filled with liquid,
such as vases on the speaker or near it.
4. Note that the amplifier is not
completely disconnected from the AC
mains service unless the mains power
cord is removed from the amplifier or the
mains outlet.
Console top mounting
If the 1030A’s are used for near field monitor-
ing, avoid mounting them on the meter bridge
of the console. Instead position the speakers
slightly behind the console by using floor
stands or wall mounts. This prevents the
first reflections from the console surface from
coloring the sound.
Setting tone controls
The response of the system may also have
to be adjusted to match the acoustic envi-
ronment. The adjustment is done by setting
the three tone control switch groups ‘treble
tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear
panel of the amplifier. The factory settings
for these controls are ‘All Off’ to give a flat
anechoic response. See Table 1 for sug-
gested tone control settings. Figure 5 shows
the effect of the controls on the anechoic
response. Always start adjustment by setting
all switches to ‘OFF’ position. Then set only
one switch to the ’ON’ position to select the
response curve needed. If more than one
switch is set to ‘ON’ (within one switch group)
the attenuation value is not accurate.
WARNING!
Maintenance
This equipment is capable of producing
sound pressure levels in excess of 85 dB,
which may cause permanent hearing
damage.
No user serviceable parts are to be found
within the amplifier unit. Any maintenance
or repair of the 1030A unit should only be
undertaken by qualified service personnel.
Accessories
Safety considerations
Although the 1030A has been designed
in accordance with international safety
standards, to ensure safe operation and to
maintain the instrument under safe operating
conditions, the following warnings and cau-
tions must be observed:
Order code
Protective grille
Wall mount
1030-409
1030-404-V/H*
1030-405-V/H*
Floor stand
Vertical / horizontal mounting
The speakers are normally delivered set
up for vertical mounting. Horizontal mount-
ing should be avoided due to the increased
likelihood of early reflections that degrade
the the direct sound. If horizontal mounting
is needed the DCW plate may be rotated so
that the Genelec logo remains horizontal by
removing the four corner screws of the DCW
and carefully lifting and turning the DCW.
*State the desired speaker orientation
V=vertical or H=horizontal when ordering
these accessories.
1. Servicing and adjustment must only
be performed by qualified service
personnel. The amplifier’s rear panel must
not be opened.
Guarantee
This product is supplied with one year guar-
antee against manufacturing faults or defects
that might alter the performance of the 1030A
unit. Refer to supplier for full sales and guar-
antee terms.
2. Do not use this product with an
unearthed mains cable as this may lead to
personal injury.
3. To prevent fire or electric shock, do not
Download from Www.Somanuals.com. All Manuals Search And Download.
1030A Operating Manual
100
100
95
90
85
80
75
70
65
60
55
50
95
0
15
TREBLE TILT
90
BASS TILT
85
80
30
45
75
BASS ROLL-OFF
70
65 100
60 95
55 90
20
100
1k
10k
20k
20
100
1k
10k
20k
Figure 4. The upper curve group shows the horizontal directivity
Figure 5. The curves show the effect of the bass tilt, treble tilt and
bass roll-off controls on the free field response.
characteristics of the 1030A in vertical configuration measured at 1 m.
The lower curve is a 1/3 octave band power response, measured in an
IEC approved reverberation chamber.
SYSTEM SPECIFICATIONS
CROSSOVER SECTION
AMPLIFIER SECTION
Lower cut-off frequency, -3 dB:
Upper cut-off frequency, -3 dB:
< 52 Hz
> 20 kHz
Input connector XLR female:
Bass amplifier short term output power with a
4 Ohm load:
pin 1 gnd
pin 2 +
80 W
Free field frequency response of system:
55 Hz - 18 kHz (± 2.5 dB)
pin 3 -
Treble amplifier short term output power with an
Input impedance:
10 kOhm balanced
8 Ohm load:
Maximum short term sine wave acoustic output on
axis in half space, averaged from 100 Hz to 3 kHz:
@ 1m > 105 dB SPL
50 W
Input level for 100 dB SPL output @ 1m:
variable from +6 to -6 dBu
Long term output power is limited by driver unit
protection circuitry.
@ 0.5m > 111 dB SPL
Input level for maximum short term sine wave output
of 105 dB SPL @ 1m:
Maximum long term RMS acoustic output in same
conditions with IEC weighted noise (limited by
driver unit protection circuit):
Amplifier system distortion at
nominal output:
variable from +11 to -1 dBu
THD
< 0.08%
< 0.08%
< 0.08%
< 0.08%
@ 1m > 99 dB SPL
@ 0.5m > 105 dB SPL
Subsonic filter below 50 Hz :
Ultrasonic filter above 25 kHz:
Crossover frequency, Bass/Treble:
Crossover acoustical slopes:
18 dB/octave
12 dB/octave
3.5 kHz
SMPTE-IM
CCIF-IM
DIM 100
Maximum peak acoustic output per pair above
console top, @ 1 m from the engineer with music
Signal to Noise ratio, referred to full output:
material:
> 115 dB
Bass
Treble
> 95 dB
> 95 dB
Self generated noise level in free field @ 1m
on axis: < 10 dB (A-weighted)
24 - 32 dB/octave
Mains voltage:
230, 100/200 or 115/230V
according to region
Treble tilt control operating range in 2 dB steps:
from +2 to -4 dB & MUTE
Harmonic distortion at 90 dB SPL @ 1m on axis:
Freq:
60...150 Hz
> 150 Hz
< 3%
< 0.5%
Voltage operating range:
Power consumption:
±10%
Bass roll-off control operating range in 2 dB steps:
from 0 to -8 dB @ 50 Hz
Drivers:
Bass 170 mm (6 1/2") cone
Treble 19 mm (3/4") metal dome
Both drivers are magnetically shielded.
Idle
Full output
10 VA
100 VA
Bass tilt control operating range in 2 dB steps:
from 0 to -6 dB @ 100 Hz
& MUTE
Weight:
7,6 kg (17 lb)
Dimensions:
The 'CAL' position is with all tone controls set to 'off'
and the input sensitivity control to maximum (fully
clockwise).
Height 312 mm (12 1/4")
Width
200 mm ( 7 7/8")
Depth 240 mm (9 7/16")
Genelec Document D1030AR001 Copyright Genelec Oy 3.2003. All data subject to change without prior notice
International enquiries:
In the U.S. please contact:
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
In China please contact:
Genelec, Olvitie 5
Genelec China Representative Office
Soho New Town, 88 Jianguo Road
D-1504, Chaoyang District
Beijing 100022, China
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]
Phone +86 10 8580 2180
Email [email protected]
Fax +86 10 8580 2181
Download from Www.Somanuals.com. All Manuals Search And Download.
|