Corporate Headquarters
Magnum ES42 Edge Switches
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
email [email protected]
Installation and User Guide
www
.
GarrettCom
.
com
www
.
GarrettCom . com
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Magnum™ ES42 Series Edge Switch
Installation and User Guide
Part #: 84-00141 Rev. A (02/05)
Trademarks
GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch, Edge Switch
are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc.
Ethernet is a trademark of Xerox Corporation
NEBS is a trademark of Telcordia Technologies
UL is a registered trademark of Underwriters Laboratories
Important: The Magnum ES42-Series 10/100 Mb/s Edge Switches contains
no user serviceable parts. Attempted service by unauthorized personnel shall
render all warranties null and void. If problems are experienced with Magnum
ES42 10/100 Mb/s Edge Switch products, consult Section 5, Troubleshooting,
of this User Guide.
Copyright © 2005 GarrettCom, Inc. All rights reserved. No part of this publication may
be reproduced without prior written permission from GarrettCom, Inc.
Printed in the United States of America.
www
.
GarrettCom . com
i
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Federal Communications Commission
Radio Frequency Interference Statement
This equipment generates, uses and can radiate frequency energy and if not
installed and used properly, that is in strict accordance with the manufacturer's
instructions, may cause interference to radio communication. It has been tested and
found to comply with the limits for a Class A computing device in accordance with the
specifications in Subpart J of Part 15 of FCC rules, which are designed to provide
reasonable protection against such interference when operated in a commercial
environment. Operation of this equipment in a residential area is likely to cause
interference, in which case the user, at his own expense, will be required to take
whatever measures may be required to correct the interference.
www
.
GarrettCom . com
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Contacting GarrettCom, Inc
Please use the mailing address, phone and fax numbers and email address listed below:
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
Email: [email protected]
www
.
GarrettCom . com
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
TABLE OF CONTENTS
Page
1.0
1.1
2.0
SPECIFICATIONS ............................................................................... 1
Technical Specifications ...................................................................... 1
INTRODUCTION ............................................................................... 12
Inspecting the Package and the Product............................................. 12
Product Description ........................................................................... 13
Frame Buffering and Latency ............................................................ 22
Features and Benefits......................................................................... 25
Applications for ES42 Series Edge Switches .................................... 28
INSTALLATION................................................................................. 36
DIN-Rail mounting option................................................................. 41
Power Requirements, Power Supplies for ES42 Series Switches...... 42
2.1
2.2
2.3
2.4
2.5
3.0
3.1
3.2
3.3
3.4
3.5
www
.
GarrettCom com
.
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.7
3.8
ES42H and P Series, 12VDC, 24VDC and -48VDC Installation...... 47
Connecting Ethernet Media ............................................................... 48
Connecting Twisted Pair............................................................. 50
Connecting Fiber Optic ST-type, “twist-lock”........................... 51
Connecting Single-Mode Fiber Optic........................................ 52
Power Budget Calculations for ES42 Series, Fiber Media ........ 53
Connections to NICs which support Auto-Neg RJ-45 ports...... 55
3.8.1
3.8.4
3.8.5
3.8.6
4.0
4.1
OPERATION ....................................................................................... 56
Dual-Speed Functionality, and Switching ......................................... 56
Auto-cross (MDIX), Auto-negotiation and Speed-sensing................ 58
Dual LEDs, Front-panel and side-panel (Magnum ES42 Series) .... 59
Hardware operated Alarm Contact for monitoring power................. 60
TROUBLESHOOTING ...................................................................... 61
Before Calling for Assistance ............................................................ 62
When Calling for Assistance ............................................................. 64
Return Material Authorization (RMA) Procedure............................. 65
4.2
4.3
4.4
5.0
5.1
5.2
5.3
www
.
GarrettCom . com
v
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
5.4 Shipping and Packaging Information................................................. 67
APPENDIX A: WARRANTY INFORMATION......................................... 69
Revisions
Rev A 05/05: Minor updates on MDIX (Auto-cross)
Rev A 02/05: Initial release of this user manual for ES42 Edge Switches
GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or
model offerings without notice.
www
.
GarrettCom . com
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
1.0
1.1
SPECIFICATIONS
Technical Specifications
Ports Performance
When a port is operating at 100Mbps:
Data Rate: 100Mbps
When a port is operating at 10 Mbps:
Data Rate: 10 Mbps
Network Standards
100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX
10 Mb: Ethernet IEEE 802.3, 10BASE-T
Auto-sensing for speed: IEEE 802.3u
Packet-Processing Between Domains
Filter and Forward Rate from 100Mbps ports: 148,800 pps max
Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max.
Processing type: Store and Forward, non-blocking
Auto-learning: 2K address table
www
.
GarrettCom . com
1
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Address buffer age-out time: 300 sec.
Packet buffers memory: 128KB, dynamically shared on all domains
Installation and User Guide (05/05)
Latency (not including packet time):
100 to 10 Mbps: 5µs
10 to 100Mbps: 15µs
Path Delay Value: 50 BT on all ports
LLL(Link-Loss-Learn): Factory default is activated on port 1 and 2
(allow to flush the internal address buffer , and qualify to use with S-Ring and
RSTP for faster recovery in ring topology)
Maximum Ethernet Segment (or Domain) Lengths
10BASE-T (Unshielded twisted pair)
100BASE-TX (CAT 5 UTP)
100BASE-FX, half-duplex: (multi-mode)
100BASE-FX, full-duplex: (multi-mode)
100BASE-FX, half-duplex: (single-mode)
- 100 m (328 ft)
- 100 m (328 ft)
- 412 m (1350 ft)
- 2 km (6,562 ft)
- 412 m (1350 ft)
100BASE-FX, full-duplex: (single-mode)
- 20 km (65,620 ft)
100BASE-FX, full-duplex: (single-mode, long reach) - 40 km (131,240 ft)
www
.
GarrettCom . com
2
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Operating Environment
ES42:
32ºF to 104ºF (0ºC to 40ºC)
ES42H: -13ºF to 140ºF (-25ºC to 60ºC) Long term per agency tests (UL).
-40ºF to 149ºF (-40ºC to 85ºC) Short term per IEC Type tests.
ES42P: -40ºF to 167ºF (-40ºC to 75ºC) Long term per agency tests (UL).
-58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests.
Storage Temperature,
All models:
-40ºF to 160ºF (-40ºC to 85ºC)
Cold Start:
ES42H to -20ºC
ES42P to -40ºC
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude (All models): -200 to 5000ft. (-60 – 15,000 m)
Conformal Coating (optional) for humidity protection
Note: H and P models are designed for NEBS compliance, including, vibration, shock and
altitude.
www
.
GarrettCom . com
3
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Packaging:
Enclosure: Rugged sheet metal (Steel).
Dimensions of the Switch unit:
3.7 in H x 3.0 in W x 1.7 in D (9.4 cm x 7.6 cm x 4.3 cm)
Weight: all models: 9.5 oz. (285g);
Power supply, –d, and i: 5.8 oz (165g)
–Hd, and Hi: 5.8 oz (165g)
–Pd, and -Pi: 7.9 oz (225g)
Cooling Method:
Convection on the office model. The hardened (H) factory floor and premium (P)
temperature un-controlled location models have closed cases to withstand dirt and use
special thermal techniques to transfer heat to the outside of the case for cooling.
ALARM RELAY Terminal Block, H and P models only, two screw terminals:
Internal 60VA relay contact: Open for power Off, closed for power On (Hardware).
www
.
GarrettCom . com
4
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
POWER SUPPLY
These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked
“Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output
voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and suitably rated output current (i.e. 100mA to
500mA).When connected to a 48V centralized DC source, these products shall be provided
with a Listed 5 A DC fuse in the supply circuit.
AC POWER SUPPLY ( using an external power adapter):
All models have an (8-15)VDC output with 6ft long cord and a 2.5mm center +ve jack. The
external AC power supplies are temperature rated to match the Edge Switch ratings.
Office Models Ratings (0 to 40°C)
North America (-d) models. Input: direct plug-in 95-125vac at 60 Hz.
Output:12vdc, 1Amps
www
.
GarrettCom . com
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
International (-i) models. Input: 240vac at 50Hz with IEC 320 connector for the user
supplied AC power cord.
Output:12vdc, 1Amps
Factory Floor Models (H) Ratings (-25 to 60°C)
North America (-Hd) models. Hardened, factory floor temperature rated. Input: 6ft AC
3power cord to IEC 320 connector on the 100-240vac 47-63Hz external power adapter.
Output:12vdc, 1.25Amps
International (-Hi) models. Factory floor temperature rated. Input: IEC 320 connector on
the 100-240vac 47-63Hz external power adapter. Requires a user supplied power cord
Output:12vdc, 1.25Amps.
Temperature un-controlled Premium(P) Ratings (-40 to 75°C)
North America (-Pd) models. Outdoor temperature rated. Input: 6ft AC power cord to IEC
320 connector on the100-240vac 47-63Hz external power adapter.
Output:12vdc, 2Amps.
International (-Pi) models. Outdoor temperature rated. Input: IEC 320 connector on the
100-240vac 47-63Hz external power adapter. Requires a user supplied power cord.
Output:12vdc, 2Amps.
www
.
GarrettCom . com
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Direct DC POWER SUPPLY : built-in terminal
block for +, -, ground along with 12VDC jack
12V DC internal (range 8.0 to 15V DC),
24V DC internal (range 10 to 36V DC),
-48V DC internal (range 30 to 60V DC),+ , -, ground.
Note: DUAL-SRC-24KIT- For ES42H or P -24VDC unit only (sold separately). See 3.6.
Power Consumption: See Section 3.6.
Note 1: the 12V DC jack can be used for dual source DC input using an AC adapter and
the DC terminal block. Power supply protection is provided by internal diodes.
Note 2: The Direct DC power floats. The user may ground either “+” or “-” if desired.
Power Consumption, all models: 7.0 watts typical, 9 watts max.
www
.
GarrettCom . com
7
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Port Connectors:
RJ-45 Ports: support 100BASE-TX and 10BASE-T with auto-cross (MDIX).
They are shielded 8-pin female connectors for shielded (STP) and unshielded
(UTP) Cat 3, 4, 5 cable.
One Fiber optic port: On the ES42 Series it is 100Base-FX with a “fiber flavor”
choice of multimode SC, ST, LC or MTRJ or single mode SSC, SSCL, SST or
SLC connectors. (By default factory settings is at “Full” duplex on fiber ports)
LED Indicators (Front)
POWER: Steady ON when power applied
10/100: Steady ON for 100Mbps; OFF for 10 Mbps(copper ports only)
LK/ACT: Steady ON for LINK (LK) with no traffic, BLINKING indicates
port is transmitting / receiving (ACT).
F/H:
Steady ON for full-duplex, OFF for half-duplex (Fiber port only)
www
.
GarrettCom . com
8
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Mounting options
Metal mounting clips for panel mounting: included
DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4)
Depth: 6.0”, width: 17” Height: 2.25” (15cm D x 43cm W x 5.7cm H)
Mean Time Between Failure (MTBF) – over15 years, Telcordia (Bellcore) Method
Agency Approvals and Standards Compliance:
UL Listed (UL 60950), cUL, CE, Emissions meets FCC Part 15 Class A.
NEBS L3 and ETSI compliant.
H and P models: IEEE P1613 Env. Std for Electric Power Substations
P models: NEMA TS-2 and TEES for traffic control equipment
P models: designed for UL 2043 above-the-ceiling installation
IEC61850 EMC and Operating Conditions Class C Power Substations
Warranty: Three years, return to factory
www GarrettCom com
Made in USA
.
.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
1.2 Summary of models and descriptions:
Note: The ES42 model # consists of the base unit type and the power input. Insert S for sgl-mode
, the fiber flavor (2ff) and the power input. H- hardened, P-premium, R- Din –Rail MC2, d-
domestic, i – international power type.
The “2ff” field is for selection of the desired “fiber flavor” as listed below. The 1ff (one fiber +five RJ-
45 ports) and no ff (six RJ-45 ports only)models are also same as below, except the port options.
ES42 Models (four RJ-45 10/100 with two100Mb fiber flavor option).
ES42-2ff-d or -i = four 10/100 RJ-45+ two 100Mb ST Fiber port for office and wiring closet
(0 to 40C) using an external AC power supply.
ES42H-2ff-Hd, Hi = Hardened (H), four RJ-45+ two 100Mb Fiber port for factory floor
(-25 to 60C) using a direct DC ( 8-15VDC) and/or external AC hardened power
supply (included).
ES42H-2ff-12VDC = Same as ES42H model, except AC hardened power supply is not included
ES42H-2ff-24VDC = Same as ES42H-12VDC model, except 24VDC power input replaces 12VDC.
ES42HR-2ff-24VDC = Same as ES42H-24VDC model, but includes DIN-RAIL-MC2 mounting
ES42H-2ff-48VDC = Same as ES42H-24VDC model, except -48VDC power input replaces 24VDC.
ES42P-2ff-Pd, Pi = Premium (P), two 10/100 RJ-45+ one 10Mb Fiber port for un-controlled(outdoor)
(-40 to 75C) using direct DC (8-15VDC) and/or external AC premium power supply (included).
ES42P-2ff-12VDC = Same as ES42P-Pd, Pi, except AC Premium Power Supply is not included.
ES42P-2ff-24VDC = Same as ES42P-12VDC model, except 24VDC power input replace 12VDC.
www
.
GarrettCom . com
10
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
ES42PR-2ff-24VDC = Same as ES42P-24VDC model, but includes DIN-RAIL-MC2 mounting opt.
ES42P-2ff-48VDC = Same as ES42P-24VDC model, except -48VDC input replaces 24VDC.
Note: For dual source 24V power input to DC jack, order Model# DUAL-SRC-24Kit
“SC” = 100Base-FX-SC: multi-mode fiber optic with SC type connector, 2km.
“SSC”= 100Base-FX-SSC: single-mode fiber optic with SC type connector, 20km.
“SSCL”= 100Base-FX-SSCL: single-mode fiber optic with SC type connector, 40km.
“ST” = 100Base-FX-ST: multi-mode fiber optic with ST type connector, 2km.
“SST” = 100Base-FX-ST: single-mode fiber optic with ST type connector, 20km.
“SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector, 15km.
“MTRJ”= 100Base-FX-MTRJ: multi-mode fiber optic with MTRJ type connector, 2km.
“SLC”= 100Base-FX-SLC: single-mode fiber optic with LC type connector, 15km.
“SFC”= 100Base-FX-SFC: single-mode fiber optic with FC Screw type connector, 20km.
“SSCX”= 100Base-FX-SSCX: single-mode fiber optic with SC type connector, 100km.
Accessories
MC14-TRAY = 19” Rack-mount tray for 14-series Switch models, up to 16 units
Other Tray configurations with power supplies and power cabling included - See Section 3.3
DUAL-SRC-24KIT= Cable kit for 24VDC input power input jack for one ES42, any 24VDC model
DIN-RAIL-MC2 = Metal DIN-Rail mounting bracket for one ES42 Series Switch,
See Section 3.4
Conformal Coating (for high humidity and “tropical” applications) - request quote.
www
.
GarrettCom . com
11
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
2.0 INTRODUCTION
Installation and User Guide (05/05)
This section describes ES42 Series models, including appearance, features and
typical applications.
2.1 Inspecting the Package and the Product
Examine the shipping container for obvious damage prior to installing this
product; notify the carrier immediately of any damage which you believe occurred during
shipment or delivery. Inspect the contents of this package for any signs of damage and
ensure that the items listed below are included.
This package should contain:
1
MagnumES42Series Edge Switch unit,
1
External Power Supply, (for -d, -i, -Hd, -Hi, -Pd and -Pi models only)
Metal panel mounting clips and screws (2 each)
User Guide (this manual)
1 set
1
www
.
GarrettCom
.
com
12
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Remove the Magnum ES42 Series Edge Switch from the shipping container. Be
sure to keep the shipping container should you need to ship the unit at a later date. In the
event there are items missing or damaged contact your supplier. If you need to return the
unit use the original shipping container. Refer to Section 5 Troubleshooting, for specific
return procedures.
2.2 Product Description
Magnum ES42 Series Switches are designed as an Ethernet edge solution in
heavy-duty industrial, military and un-controlled temperature applications, as well as an
economical solution for the growing requirements of managed networks. ES42, a six port
versatile family of compact Edge switches, loaded with factory configurable fiber options
and AC/DC power input options with Alarm terminal block and innovative packaging is
ready to serve the needs of edge-of-the network applications.
The Magnum ES42 family of Edge Switches have a wide breadth of port
configurability and fiber port type options - six 10/100 copper ports or four 10/100 copper
www
.
GarrettCom . com
13
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
ports and two 100 Mb Fiber port or five copper ports with one 100Mb Fiber port built in,
covers the full range of application environments, with regular (office), Hardened (factory
floor), and Premium-rated (outdoor) versions. Extra features for heavy-duty and extended
temperature operation ranges are included selectively in the Hardened factory-floor and
Premium-rated outdoor models. The breadth of models and flavor of fiber port types offers
the best price-to-value ratio for each user and installation. The compact package is ideal for
network edge installations, and is able to be conveniently Din rail mounted to suit any
application.
The Magnum Edge switches include Link-Loss-Learn(LLL) feature (factory
configurable on ports 1 and 2 to qualify for any redundant and self-healing managed
network structures. The Link-Loss-Feature in ES42 allows the Edge switches to flush the
internal address buffers in milliseconds to permit a quick change in LAN packets flow, and
www
.
GarrettCom . com
14
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
pass the reconfiguration signal down the line to other ring switches in the redundant
structure for faster recovery. Magnum Edge switches, combined with other Magnum
managed switches, running STP/RSTP or S-Ring, can often provide high availability
Redundant LANs at economical cost.
The Magnum ES42 regular-package units
R
W
P
6
are for office and indoor wiring closet environments. These
5
P
O
R
T
P
O
R
T
are the economical base units in the ES42 Switch family. An
external AC power supply for either North America (-d,
115vac 60Hz) or international (-I, 230vac, 50Hz) is included.
The ambient temperature rating is 0°C to 40°C, office grade.
Fig 2.2a ES42 with SIX 10/100 RJ-45 only
4
3
M
E
a
d
g
g
n
u
m
E
2
4
c
2
h
1
e
S
S
w
i
t
P
M
A
1
C
D
V
2
1
www
.
GarrettCom . com
15
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
A robust metal case with convection cooling is featured. Metal mounting clips are
included, and rack-mount tray options are available.
The YELLOW labeled Magnum ES42 models (as shown in Fig
R
W
P
6
5
P
O
R
T
2.2.a, b, c) units are for office and
environments and use an external
AC power supply. A ventilated
metal case for convection
wiring closet
P
O
R
T
4
3
R
W
P
A
L
A
R
M
6
5
P
O
R
T
P
O
R
T
4
1
3
M
a
d
g
g
n
u
m
S
E
4
c
2
h
E
e
P
S
A
w
LA
R
M
M
i
t
A
cooling is featured. Ambient
operating temperature is 0° to
1
C
D
V
2
1
M
a
d
g
g
n
u
m
S
E
4
c
2
h
E
P
e
S
M
A
1
w
i
t
40°C. Storage temperature rating is -
40°to 85°C. Metal clips are included for secure panel
C
D
V
2
1
Fig 2.2b,c (ES42-1ff) with four10/100 RJ-45 and one & two 100Mb Fiber(ES42-2ff
www GarrettCom com
)
.
.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
mounting and optional DIN-Rail mounting. The regular model ES42 also has a rack-
mount option via an MC-TRAY.
The regular model, ES42, includes Link-Loss-Learn,
MDIX ports and the full range of fiber port options. The
R
W
P
6
5
P
O
R
T
regular ES42 model does not have options for Alarm and
DC power.
P
O
R
T
4
3
AL
A
R
M
The Magnum ES42H Hardened units are for
factory floor applications. The ES42H models are built
with high-grade components and are constructed using
special thermal techniques and a metal case for
Fig. 2.2.d Hardened ES42H-2ff
M
a
g
a
n
r
u
d
m
e
H
E
4
d
2
h
n
e
S
E
d
P
g
e
M
S
w
A
i
t
c
1
C
D
V
2
1
www
.
GarrettCom . com
17
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
heavy duty industrial jobs. In addition to a Hardened AC power option and jack, terminals
for internal DC power choices at 8 to15V, 24V or -48V DC are included. The ambient
temperature rating of –25 to 60C is for industrial use. No internal air flow is required for
cooling, so it resists dust, dirt, moisture, smoke and insects. Mounting options include
stand-alone panel-mounting, DIN-Rail, or rack-mount tray.
R
W
P
6
The ORANGE labeled Magnum ES42H hardened units (shown
5
P
O
R
T
PO
R
T
in Fig 2.2d & e) are designed for factory floor/Industrial
applications. Using special thermal techniques and a sealed
rugged metal case for heavy duty industrial applications, the
ES42H requires no air inflow for cooling, so the ES42H
resists dirt, moisture, smoke and insects. Choices of models
4
3
A
LA
R
M
1
M
a
g
a
n
r
u
d
m
e
H
E
4
d
2
h
n
e
E
S
d
g
e
S
w
i
t
c
for external
Fig. 2.2e Hardened ES42H-2ff
www
.
GarrettCom . com
18
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
AC or internal DC power are available. Ambient operating temperature is –25°C to + 60°C
depending on the power source used. Storage temperature rating is –25°C to + 85°C.
The RED labeled Magnum ES42P Premium-rated units are for temperature un-
controlled applications (-40 to 75°C), typically located outdoors. The
R
ES42P models are built with premium-grade extended temperature
W
P
6
5
P
O
R
T
P
O
R
T
components, and use similar thermal
techniques as the ES42H Hardened units.
In addition to a Premium-rated AC
power option and jack, terminals for
internal DC power choices at 8
4
R
3
W
P
6
5
P
O
R
T
A
L
A
R
M
P
O
R
T
4
3
M
P
1
a
d
g
r
n
e
u
m
m
i
E
u
4
2
A
L
A
R
M
S
m
E
g
e
S
w
i
t
c
h
to15V, 24V or -48V DC are included.
When used outdoors, the ES42P should
M
P
a
d
g
r
n
e
u
m
i
E
S
4
c
2
h
m
u
m
E
g
e
S
w
i
t
be
protected from rain. Mounting options include
stand-alone panel-mounting, DIN-rail, or rack-mount tray. Fig
2.2f & g, Premium model ES42P-1ff & ES42P-2ff
www
.
GarrettCom . com
19
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
The ES42P series (as shown in Fig. 2.2f & g) are premium rated units
suitable for temperature un-controlled outdoor applications. Specially designed with
premium-grade extended temperature components, the ES42P units use similar thermal
techniques to the ES42H hardened units for cooling. Mounting options include panel-
mounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC
power are available. Ambient operating temperature is between –40°C to +75°C depending
on the power source used. Storage temperature rating is between –40°C to +85°C.
All the premium and hardened models also come along with hardware
operated Alarm terminal block for providing extra reliability to the unit. The Alarm feature
allows the ES42H & P users to be aware and to monitor any internal power failure. See
section 44 for details.
The front side of the unit has four/five twisted-pair 10/100Mb switch ports and
one/two 100Mb fiber port. All the RJ-45 ports of the ES42 Series Edge switches support
www
.
GarrettCom . com
20
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
auto-cross (MDIX) operation under auto-negotiation mode. The ES42 series provides
switching among four 10/100 auto-negotiating copper ports and two 100Mb fiber ports
which may be SC, ST, MTRJ or LC multi-mode or single-mode. The ES42’s breadth of
fiber options and well as temperature options provide many networking options and
solutions in a very small footprint.
Two sets of LEDs to indicating the operating status of ports are mounted on the
top and front (for extra viewing advantage while rack-mounted). For each port, there are
Link and Activity (LK/ACT) LED’s on the top indicating that the media cables are
connected correctly and showing, by blinking, when there is traffic. The LK/ACT LED’s
are repeated on the front as 1 (port 1)…6 (port 6), whereas on the side as LA1…LA6 .
There is another set of LEDs on the front for 10 or H and 100 or F, to indicate the data rate
as well as a set to indicate duplex for ports 1 and 2 only. 10/100 indicates the speed for
copper ports, whereas F/H indicates Full and Half duplex for fiber ports only.
www
.
GarrettCom . com
21
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
There is a power (PWR) LED to indicate that the unit is turned ON. The fiber
ports on the ES42 Edge switches are multi-mode or single-mode with an SC, ST or small
form factor connector (MTRJ multi mode or LC single-mode).
The external DC power plug connector and/or “jack” and the internal DC input
terminal is provided on the rear of the unit.
2.3 Frame Buffering and Latency
The Magnum ES42 Series Edge Switches are store-and-forward switches. Each
frame (or packet) is loaded into the Switch’s memory and inspected before forwarding can
occur. This technique ensures that all forwarded frames are of a valid length and have the
correct CRC, i.e. they are good packets. This eliminates propagation of bad packets,
enabling all of the available bandwidth to be used for valid information.
While other switching technologies such as "cut-through" or "express" impose
minimal frame latency, they will also permit bad frames to propagate to the Ethernet
www
.
GarrettCom . com
22
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
network. The "cut-through" technique permits collision fragment frames, which are a result
of late collisions, to be forwarded--which add to the network traffic. There is no way to
filter frames with a bad CRC (the entire frame must be present in order for CRC to be
calculated). Since collisions and bad packets are more likely when traffic is heavy, store-
and-forward switch technology enables more bandwidth to be available for good packets
when the traffic load is greatest.
To minimize the possibility of dropping frames on congested ports, each
Magnum ES42 Series Edge Switch dynamically allocates buffer space from 128KB
memory pool, ensuring that heavily used ports receive very large buffer space for packet
storage. (Many other switches have their packet buffer storage space divided evenly across
all ports, resulting in a small, fixed number of packets to be stored per port. When the port
buffer fills up, dropped packets result.) This dynamic buffer allocation provides the
capability for the maximum resources of the Magnum ES42 Series unit to be applied to all
www
.
GarrettCom . com
23
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
traffic loads, even when the traffic activity is unbalanced across the ports. Since the traffic
on an operating network is constantly varying in packet density per port and in aggregate
density, the Magnum ES42 Series Edge Switches are constantly adapting internally to
provide maximum network performance with the least dropped packets.
When the Switch detects that its free buffer queue space is low, the Switch sends
industry standard (full-duplex only) PAUSE packets out to the devices sending packets to
cause “flow control”. This tells the sending devices to temporarily stop sending traffic,
which allows a traffic catch-up to occur without dropping packets. Then, normal packet
buffering and processing resumes. This flow-control sequence occurs in a small fraction of
a second and is transparent to an observer.
Another feature implemented in Magnum ES42 Series Edge Switches is a collision-based
flow-control mechanism (when operating at half-duplex only). When the Switch detects
that its free buffer queue space is low, the Switch prevents more frames from entering by
forcing a collision signal on all receiving half-duplex ports in order to stop incoming traffic.
www
.
GarrettCom . com
24
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
The latency (the time the frame spends in the Switch before it is sent along or
forwarded to its destination) of the ES42 Series Edge Switches varies with the port-speed
types. The length of the frame is a variable as it is with all store-and-forward switches. For
10 Mb-to-10 Mb, 10 Mb-to-100Mb or 100Mb-to-10 Mb forwarding, the latency is 15
microseconds plus the packet time of 10 Mb. For 100Mb-to-100Mb forwarding, the
latency is 5 microseconds plus the packet time of 100Mb.
2.4 Features and Benefits
ꢀ
Full 100Mb or 10 Mb switching services for high performance Ethernet
Magnum ES42 Series Switches provide Fast Ethernet switching on all ports.
They perform high speed filter/forward operations on the traffic, giving each
port’s segment a full 100Mb (or 10 Mb) of bandwidth.
ꢀ
Reduces Network Costs and provide economical solution
Magnum ES42 Series Switches offer the ideal solution to efficiently and
inexpensively connect a Twisted Pair and fiber network with 10Mb or
100Mb and help to expand the Ethernet network in a very convenient and
economical way.
www
.
GarrettCom . com
25
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
ꢀ
Choice of one or two100Mb Fiber option, more efficient Designed as a
multi-purpose media Edge Switch, the 100Mb fiber port allows the user to
convert the media from copper to fiber and the other RJ-45 port can be used
as diagnostic port or for more connectivity.
ꢀ
Installation is “Plug and Play”, operation is transparent to software
The Magnum ES42 Series Switches operate as hardware switches, only
forwarding those packets from each domain that are needed on the other
domains. Internal address tables are self-learning, enabling users to change
port connections or 10/100 domains without affecting operations.
ꢀ
ꢀ
Two sets of LEDs for viewing status from any angle.
Each ES42 Series Edge Switch is equipped with two sets (front and side) of
LEDs to provide status information when viewed at almost any angle or
mounting arrangement whether rack (MC14- Tray) or Din-Rail mounted.
Rugged metal case, Industrial grade ES42 Series have a robust design and
are packaged in a rugged sheet metal enclosure to ensure high reliability and
durability even when placed in industrial or outdoor applications.
www
.
GarrettCom . com
26
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
ꢀ
Qualified to use for temperature un-controlled “outdoor” application
The Magnum ES42P Premium rated versions of Edge Switches have an
ambient temperature rating between –40ºC to +75ºC for DC models and
qualify for temperature un-controlled “outdoor” application.
ꢀ
Efficient Compact design, for all purpose convenient mounting
Featuring a compact steel case with an external AC and internal DC power
supply, Magnum ES42 Series of Edge Switches can be installed in small
spaces in cabinets, on table tops, in racks, walls or DIN-Rail mounted and in
trays such as the Magnum MC14-TRAY.
ꢀ
ꢀ
MDIX ports to eliminate cross-over cable while cascading All the
Magnum ES42 Series Switches are featured with MDIX (auto-cross), which
easily allow cascading with other Switch, Hubs or media Edges without
using the cross-over cable.
Hardware operated Alarm terminal block for ES42H and ES42P
The Alarm contact option on ES42H and ES42P enables monitoring for
internal power failure, and provides extra reliability to the hardened Switch
www
.
GarrettCom . com
27
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
ꢀ
Link-Loss-Learn feature for faster recovery in redundant managed
network
The LLL feature qualifies the Edge switches to actively work along with
redundant network structure as a client switch and allow a faster recovery
during ring break.
2.5 Applications for ES42 Series Edge Switches
Available in three “hardiness” models (Yellow - “office/wiring closet”, Orange –
“Hardened”, Red- “Premium rated (outdoor)”), and hundreds of port-type combinations,
Magnum ES42 Series Edge Switches fit very well in almost any environment to enable
users to scale their networks quickly and cost effectively. The edge-of-the-network
connectivity solutions offered by Magnum Edge Switches provide convenient, economical,
and reliable solutions as well as an active role on the managed redundant network setup for
faster recovery. The compact Magnum ES42 Series assists fast expanding network
www
.
GarrettCom . com
28
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
requirements via providing edge support and reliability to the managed redundant network.
The Dual-Speed and Dual-media functions support a mixed environment of 10 Mbps and
100Mbps users with copper and fiber media. The switched full duplex fiber port also
provides high bandwidth and longer distance support. The up-link feature of 100Mb fiber
on Ports 1 and 2 enable easy expansion for the on-going demand of Ethernet networks. The
10/100Mbps auto-negotiating MDIX copper ports and the breadth of 100Mbps fiber ports
enable easy interfacing with existing cable plant and equipment. Models of ES42 Edge
Switches are available for even the most extreme temperatures. The ES42’s rugged case
provides extra support in the harshest industrial environments. Link-Loss-Learn is an
additional feature to provide the extra reliability to the redundant network and an
economical solution for faster recovery, during the ring break.
www
.
GarrettCom . com
29
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Example1. Supermarket application for ES42
R
W
P
R
6
1
3
5
7
W
5
P
W
R
P
OR
TX
1
5
T
RX
TX
RX
LK
P
ACT
F/H
ACT
F/H
10/
100
P
O
R
T
5
P
O
R
1
7
T
L
K
L
K
P
O
R
T
ACT
F/H
ACT
F/H
ACT
ACT
F/H
ACT
F/H
F/H
ACT
F/H
4
3
C
ON
S
OL
E
P
O
R
T
A
L
A
R
M
L
K
LK
RX
TX
RX
TX
L
K
L
K
L 8
2
2
K4
6LK
6
3
A
LA
R
M
A
LA
R
M
GarrettCom Magnum 6K16
Managed Switch
2
M
P
a
d
g
r
n
e
um
m
E
S
4
c
2
h
M
P
1
a
d
i
u
g
r
m
n
e
um
m
E
E
m
P
4
2
g
M
e
S
A
w
i
u
S
i
t
1
E
P
C
g
M
e
S
D
w
V
A
i
t
1
c
h
2
1
C
D
V
2
1
Magnum ES42 Premium
Magnum ES42 Premium
R
Edge Switch ver
2
W
P
Edge Switch ver
2
6
5
P
OR
T
P
O
R
T
R
W
P
4
6
3
5
P
OR
T
P
O
RT
A
LA
R
M
4
3
2
A
LA
R
M
M
P
1
a
d
g
r
n
e
u
m
m
i
E
4
c
2
h
u
S
m
E
P
g
e
M
S
A
w
i
t
1
C
D
V
Ma
P
1
gn
um
m
E
S
2
42
1
r
e
i
u
m
E
P
d
g
M
e
S
A
w
i
t
1
c
h
C
D
V
2
1
Magnum ES42 Premium
Edge Switch ver
R
W
P
2
R
6
R
W
5
P
P
O
RT
W
6
P
O
RT
P
Magnum ES42 Premium
Edge Switch ver
5
6
P
OR
T
5
P
O
R
P
O
R
T
T
P
OR
T
2
4
3
4
4
3
3
A
L
A
R
M
A
LA
R
M
A
LA
R
M
2
2
M
P
a
d
g
r
2
nu
e
m
m
i
E
S
4
M
P
2
a
d
gn
u
m
u
m
M
P
m
i
a
d
E
m
g
r
E
n
e
4
P
M
A
um
r
2
g
e
e
E
S
S
4
2
u
S
w
i
t
m
i
c
1
h
u
P
E
m
g
e
C
E
M
S
D
P
M
A
A
w
g
i
t
V
e
c
S
1
h
w
2
i
t
C
D
V
1
c
1
h
C
D
2
V
1
2
1
Magnum ES42 Premium
Magnum ES42 Premium
Edge Switch ver
Magnum ES42 Premium
Edge Switch ver
Edge Switch ver
2
2
2
In this example, the
supermarket required a Data
Mining function to store all the transaction with an ongoing demand to expand the network.
www
.
GarrettCom . com
30
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
This need can be easily met using the economical Magnum ES42 Edge Switch. Additional
functionality includes the ability to transfer data across large distances with multi- or
single–mode fiber while securing the LAN from EMI and wire tapping.
The ES42’s six ports in a small, reliable enclosure provide an effective solution to
for transferring real-time transactions from the store to the storage device in the control
room. The easily deployable through Din-rail option and the dual power source of
flexibility along with flavor of fiber option for distance, the ES42 easily meets all the
requirements of supermarket. The plug-n-play ES42 not only provides a reliable solution
but also reduces operational costs significantly.
www
.
GarrettCom . com
31
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Example 2: ES42H and CSN14H
In this industrial networking application, the new PLC units are deployed on a network
expansion, and each PLC required one (or two for redundancy) Ethernet ports to carry
status and control data to the control center. The ES42H and CS14H provide a good
solution with their multiple options and hardened features. The two Fiber ports on the Edge
switches are ideal for secure data communications over long distances. Built with high-
grade components, efficient cooling techniques and having no openings for dirt to enter, the
ES42 Series Edge Switches provide the very effective solution for this need. The CS14H
offers additional and affordable fiber connectivity to the ES42H where needed.
www
.
GarrettCom . com
32
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
1
3
5
7
9
11
13
15
17
19
21
23
1
3
5
7
8
A
C
T
A
C
T
F
/
H
F
/H
A
C
T
A
C
T
F
/
H
F
/
H
A
C
T
A
C
T
F
/
H
F
/
H
A
C
T
A
C
T
F
/
H
F
/
H
2
4
6
8
10
12
14
16
18
20
2
2
24
2
4
6
t
t
C
o
m
r
e
G
a
r
6
V
6
K1
nu
m
M
a
g
O
S
P
e
t
t
C
o
m
a
r
r
e
t
t
C
o
m
G
a
r
r
G
K1
6
V
6
K
16
V
6
ag
n
um
M
agnum
M
PWR
PWR
e
t
o
m
G
a
r
r
t
C
6K
1
6V
g
n
um
M
a
E
O
RT
S
P
C
R
W
P
6
5
P
O
R
T
P
O
R
T
PW
R
4
3
R
T
C
ON
OL
P
A
L
A
R
M
2
M
E
a
g
r
n
e
u
m
E
P
4
2
h
m
i
u
S
m
P
d
g
e
M
A
1
S
w
i
t
c
PLC
C
D
V
2
1
i
M
a
c
PLC
R
R
W
W
P
P
6
6
5
5
P
O
R
P
O
R
T
T
P
O
R
P
O
R
T
T
4
4
3
3
A
L
A
R
M
R
A
L
A
R
M
W
P
6
5
P
O
R
2
T
2
PO
RT
M
M
1
a
d
a
d
g
r
n
e
g
r
n
e
u
m
u
m
E
E
P
4
2
h
P
4
2
h
i
M
a
c
4
m
m
i
u
S
PLC
PLC
i
u
S
m
3
m
E
E
P
g
P
g
e
e
M
A
1
S
M
A
1
S
w
w
i
t
i
t
c
c
C
C
D
A
L
A
R
M
D
V
V
2
2
1
1
2
M
a
1
g
r
n
e
u
m
E
P
4
2
m
i
u
S
m
E
P
d
g
e
M
A
1
S
w
i
t
c
h
C
D
V
2
1
i
M
a
c
i
M
a
c
ES42H in a Industrial application
www
.
GarrettCom . com
33
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Example 3: ES42P: In this example, the Magnum ES42P premium Edge Switches are
deployed to serve as a secure corporate or transportation surveillance system. CCTV
cameras may be spread out over many miles in temperature un-controlled locations and
with pan, tilt and zoom (PTZ) controlled through an Ethernet copper port .The premium
Edge Switches provide two fiber segments for secure long distance (2-40km)
communication while being installed in temperature un-controlled cabinets and allowing a
full range of AC and DC power options. The four copper ports at the remote location
provides access for other Ethernet equipment such as motion detectors or will act as a test
port for maintenance personnel with up-link for access to a central LAN and central file
servers.
www
.
GarrettCom . com
34
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
1
3
5
7
9
11
13
1
5
17
19
21
23
1
3
5
7
8
A
C
H
T
A
C
T
F
/
F
/
H
A
C
T
A
C
T
H
F
/
H
F
/
A
C
T
A
C
T
F
/
H
FH/
i
M
a
c
A
C
T
A
C
T
F
/
H
FH/
2
4
6
8
18
20
22
24
2
4
6
10
1
2
1
4
16
R
W
P
6
5
PO
R
T
PO
R
T
4
3
A
L
A
R
M
2
M
1
a
g
r
n
e
u
m
E
uSm
P
4
c
2
h
i
M
a
c
CCTV Camera
m
i
E
P
d
g
e
M
S
w
A
i
t
1
C
D
V
2
1
R
W
P
6
5
PO
R
T
PO
R
T
4
3
A
L
A
R
M
2
M
1
a
g
r
n
e
u
m
E
P
4
2
h
CCTV Camera
m
i
u
S
m
E
d
P
g
e
M
S
w
A
i
t
c
1
C
D
V
2
1
R
W
P
6
5
P
O
R
T
PO
R
T
i
M
a
c
4
3
A
L
A
R
M
2
M
a
g
r
n
e
u
m
E
P
42
m
i
u
S
m
E
P
d
g
e
M
S
w
A
i
t
c
h
1
C
D
V
2
1
i
M
a
c
R
6
W
5
P
O
R
P
T
6
PO
R
T
5
P
O
R
T
P
O
R
T
4
3
4
3
A
L
A
R
M
i
M
a
c
A
L
A
R
M
CCTV Camera
2
6
2
M
1
a
g
r
5
n
e
u
PO
RT
m
E
i
P
4
2
P
O
RT
M
1
a
g
r
m
nu
e
i
u
S
m
m
m
E
E
P
4
2
CCTV Camera
P
d
g
e
M
A
1
S
i
u
S
w
m
t
c
h
E
d
4
P
g
e
C
M
S
D
3
A
w
i
t
c
h
V
1
2
C
1
D
V
2
A
L
A
R
M
1
2
M
a
d
g
r
n
e
u
m
E
P
4
c
2
h
m
i
u
S
m
E
P
g
e
i
M
a
c
M
A
1
S
w
i
t
C
D
V
CCTV Camera
2
1
CCTV Camera
ES42p in a Outdoor application
The ideally suited ES42P with its diversified features, premium rated approvals and cost-
effective solution, make an ideal choice in outdoor environments.
www
.
GarrettCom . com
35
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.0
INSTALLATION
This section describes the installation of the Magnum ES42 Series Edge
Switches, including location, mountings,
power supply options and media connection.
3.1 Locating the Edge Switch Unit
All the ES42 Series Switches operate in
transparent half-and full-duplex mode. The
store and forward switch easily takes care of
network traffic and can be used as a useful,
economical tool to expand an existing
network.
Secure attachment of
clips for panel -
www
.
GarrettCom . com
36
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
The compact and lightweight design of the Magnum ES42 Series allows it to be
easily installed in almost any location. A Velcro strip may be used for mounting the unit
on a vertical surface such as a wall or cabinet, or for securing the unit on a table-top or
shelf. Alternatively, metal mounting clips and screws are included for a rugged and secure
mounting in any orientation.
Installation of the Magnum ES42 Series Edge Switches is a simple procedure. The
installation location is dependent upon the physical layout of the Ethernet network and
associated cabling. Make sure the unit is installed in a location that is easily accessible to
an AC power outlet or the appropriate DC source and where cooling is not inhibited. The
green Power (PWR) LED must turn ON when power is applied.
www
.
GarrettCom . com
37
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.2 MC14-TRAY for Rack Mounting of ES42 Series Switches
For 19” rack-mounting
of Magnum ES42 series Edge
Switches, a rack-mount tray is
available, the MC14-TRAY. The
Edge Switches are mounted with
the DC power jack in the back,
with the fiber and the RJ-45
connectors in the front. Any mix
of the Edge Switches and/or
www
.
GarrettCom . com
38
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Media Edges may be placed on a tray, up to a maximum of 8 units. (The mounting spaces
of the MC14-TRAY are specific to the Magnum products and will not permit other models
to be properly mounted).
In a typical installation, the MC14-TRAY, 19” rack-mount tray will hold a few (three to
eight) ES42 Series Edge Switches, with their power supplies plugged into power strips (not
included) in the rear area of the tray. Metal mounting screws in the bottom-front hold the
Edge Switches firmly in place. The beveled-top edge of the units permits the LEDs of each
unit to be viewed for operational status, even when the units are very close together.
3.3 MC14-TR+PS9 and MC14-TR+PS9X2 for Rack Mounting Media Edges
The MC14-TR+ PS9 and MC14-TR+PS9X2 are other options for rack mounting the mix of
Magnum 10Mbps and 100Mbps Edge Switches and Media Edges together in a 19” rack-
mount tray. These models come with built-in common universal AC power supply rated at
55 watts at 50°C ambient,9VDC output, and supporting up to 2-3 Switches for MC14-
TR+PS9 and 5 units ES42 Series for MC14-TR+PS9X2. The MC14-TR+PS9X2 Model
www
.
GarrettCom . com
39
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
has two groups of eight units per power supply. The power supplies have auto-ranging AC
input for use worldwide.
The side-view < here is an example of
an installation of the model MC14-
TR+PS9, 19” rack-mount tray, holding
a few ES42, and 14E Media Edges,
each with their power input plugged
into the built-in common AC power
supply in the rear area of the tray. (AC
PS units that come with the office
models of the Edge Switch’s are not
used). Because of the thicker size, only
eight ES42 units can fit in one MC14-
TRAY.
Metal mounting screws in the bottom-front hold each of the Edge Switches,
securing them in the tray and enabling separate removal for service. The dual LEDs permit
viewing of Edge Switch status from any angle.
www
.
GarrettCom . com
40
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.4 DIN-Rail mounting option
The Magnum ES42H and ES42P Edge Switches, designed for use in “Factory
Floor” Industrial Ethernet
environments, are available for
DIN-Rail mounting in an
enclosure having DIN Rails
A Magnum ES42H is
shown alongside the DIN-Rail-
MC2 bracket here ->
The metal DIN-Rail
mounting hardware is optional
and needs to be ordered as a
separate item, e.g. Model #DIN-
RAIL-MC2. It comes with four
screws to attach the bracket to
the MC unit. The rail clip is
spring-loaded with a pull-up latch at the top for easy “snap-on” attachment and removal.
The Magnum ES42 models with “HR” have 24VDC power, and have the DIN-
Rail-MC2 bracket included and assembled with the MC unit at the factory.
www
.
GarrettCom . com
41
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.5 Power Requirements, Power Supply Types for ES42 Series Switches
Magnum ES42 Series Switches are power-efficient and can work with an external AC
power supply. Magnum ES42 Series require a nominal 12VDC input version. The
extended temperature (H and P) versions are used for heavy duty industrial applications.
The 12V DC power input jack has a plug of 2.5mm,
center +ve , with 6 ft. cord. All the AC power supply
info detail is provided in Technical Specs Section 1.1.
The ES42 Series are designed to be used with UL
listed Class II power supplies.
ES42H or P with 12VDC/ 24VDC/ -48VDC
The ES42 Edge Switches provide reliable operation,
www
.
GarrettCom . com
42
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
withstand higher temperature environments, and provide the DC power choices to the user
to deploy in uncontrolled temperature environments.
The Direct DC (Internal) 12V DC (8 – 15V DC) has a built-in terminal block for +, -,
ground. The 9V DC jack is also present. Detail information about the 12 VDC, the 24V DC
and the –48V DC is provided in the Technical Specifications Section 1.1.
The various models of DC power type and extended ambient temperature power supplies
are numerous and your choice needs to be called out on your order.
Note: When connected to a -48 V centralized dc source these products are to be installed
only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).
www
.
GarrettCom . com
43
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.6 Powering the ES42H and ES42P (DC internal) with 12V, 24V or –48VDC power
input
Each Magnum ES42H/ES42P-Series is
equipped with an internal DC power supply, and
has built-in screw terminals for secure attachment
of the power input leads. Three DC power models
support a range of power input types. The three
DC power input terminal block choices are for
use with 12VDC, 24VDC or -48VDC power.
Where an AC power adaptor is used, DC is
supplied via the jack. Power input from the DC terminal block and the jack and both may
be connected simultaneously for power input redundancy.
www
.
GarrettCom . com
44
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Note: The ES42H or P models with 24VDC
support the Dual Source 24V input option. An
external Dual-SRC-24KIT (SHOWN AT
RIGHT…and sold separately, or a customer-
supplied equivalent) can be used to input
24VDC power to the ES4H or P unit via the
jack. This is for 24VDC models only.
www
.
GarrettCom . com
45
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.6 continued, DC Power Terminals: “+”, “-”, gnd
GND: Terminal for “earth” or ground wire connection to the ES42H chassis
Input Voltage: 12VDC
24VDC
-48VDC
Alarm
Contact
Terminal
24VDC
(10-36VDC)
-48VDC
(30-60VDC)
12VDC
(8-15VDC)
(12V or 24V)
(10-30VDC)
(12V)
(8-15VDC)
(12V)
(8-15VDC)
Input
current:
0.8 amp.(12V DC)
0.4 amp max.(24V DC)
0.2 amp max.(-48V DC)
Power Consumption: 7 watts typical, 9 watts max.
www . GarrettCom com
.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.7 ES42H and P Series, DC-powered, 12VDC, 24VDC and -48VDC Installation
This section describes the proper connection
of the -48VDC leads (or 24VDC, 12VDC leads) to the
DC power terminal block on the Magnum ES42H Edge
Switch (as shown in the Figure). The DC terminal block
on the Magnum ES42H is located on the left side of the
unit and is equipped with three (3) screw-down lead
posts. The power terminals are identified as positive (+)
and negative (-), and they are floating inside the unit so
that either of the terminals may be grounded by the user
if desired. The chassis is “earth” or ground (GND). The
connection procedure is straightforward. Simply insert
www
.
GarrettCom . com
47
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
the DC leads to the ES42H’s power terminals, positive (+) and negative (-) screws. The use
of Ground (GND) optional; it connects to the ES42H chassis. Ensure that each lead is
securely tightened from the top, as shown on above picture with arrow.
NOTE: Always use a voltmeter to measure the voltage of the incoming power supply
and figure out the +ve potential lead or -ve potential lead. The more +ve potential lead
will connect to the post labeled “+ve” and the rest to the “-ve”.
The GND can be hooked up at the last.
When power is applied, the green PWR LED will illuminate.
3.8 Connecting Ethernet Media
The Magnum ES42-Series Edge Switches can be connected to two media types
i.e. fiber and copper (RJ-45) types, runt at 100BASE-TX, 10BASE-T and 100BASE-FX
only. CAT 5 cables should be used when making 100BASE-TX connections. When the
www
.
GarrettCom . com
48
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum
distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 10BASE-
FL or 100BASE-FX multi-mode, 50/125 or 62.5/125 microns cabling can be used, whereas
for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer
cable distance and higher bandwidths as compared to copper wiring.
Media
IEEE Standard
10BASE-T
Connector
RJ-45
Twisted Pair (CAT 3 or 5)
Twisted Pair (CAT 5)
Fiber (Multi-mode)
Fiber (Single-mode)
Fiber (Multi-mode)
100BASE-TX
100BASE-FX
100BASE-FX
100BASE-FX
RJ-45
ST, SC
SC, LC
MTRJ
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps
and 100Mbps) be used whenever possible in order to provide flexibility in a
mixed-speed network, since ES42-series switch ports are auto-sensing for either
10 and 100Mbps. Note that the auto-cross function does not operate, if the port
is fixed or not supporting auto-negotiation.
www
.
GarrettCom . com
49
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.8.1
Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5, Unshielded or
Shielded)
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and
shielded twisted pair cables.
1. Using standard twisted pair media, insert either end of the cable with a RJ-45 plug
into the RJ-45 connector of the port. Note that, even though the connector is shielded,
either unshielded or shielded cables and wiring may be used.
2. Connect the other end of the cable to the corresponding device.
3. Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established. If this
does not help, ensure that the cable is connected properly and that the device on the
other end is powered and is not defective.
4. For Port # 1 or 1SW, if the LINK LED is not illuminated, move the switch which
has a cross-over or up-link for linking to another hub or Switch.
www
.
GarrettCom . com
50
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
3.8.2
Installation and User Guide (05/05)
Connecting Fiber Optic ST-type, “twist-lock”
The following procedure applies to installations using ST-type fiber connectors.
This procedure applies to ports using multi-mode ST fiber connectors.
1. Before connecting the fiber optic cable, remove the protective dust caps from the
tips of the fiber connectors. Save these dust caps for future use.
2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
dampened in alcohol. Make certain the connectors are clean before connecting.
Note:
One strand of the duplex fiber optic cable is coded using color bands
at regular intervals; you must use the color-coded strand on the associated
ports at each end of the fiber optic segment.
3. Connect the Transmit (TX) port (light colored post) on the Magnum Fiber port to
the Receive (RX) port of the remote device. Begin with the color-coded strand of
the cable for this first TX-to-RX connection.
4. Connect the Receive (RX) port (dark colored post) to the Transmit (TX) port of the
remote device. Use the non-color coded fiber strand for this.
5. The LINK LED on the front of the fiber connector will illuminate when a proper
connection has been established at both ends (and when power is ON in the unit). If
LINK is not lit after cable connection, the normal cause is improper cable polarity.
Swap the fiber cables at the fiber connector to remedy this situation.
www
.
GarrettCom . com
51
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.8.3
Connecting Fiber Optic SC-type, "Snap-In"
The following procedure applies to installations using SC-type fiber
connectors, i.e., using multi-mode SC and SC single-mode. While connecting
fiber media to SC connectors, simply snap on the two square male connectors
into the SC female jacks of the Fiber connector until it clicks and secures.
3.8.4
Connecting Single-Mode Fiber Optic
When using single-mode fiber cable, be sure to use single-mode fiber port
connectors. Single-mode fiber cable has a smaller diameter than multi-mode
fiber cable (9/125 microns for single-mode, 50/125 or 62.5/125 microns for
multi-mode where xx/xx are the diameters of the core and the core plus the
cladding respectively). Single-mode fiber allows full bandwidth at longer
distances, about 20Km with the multi-mode SC.
The same procedures as for multi-mode fiber apply to single-mode
fiber connectors. Follow the steps listed in Section 3.8.2 above.
www
.
GarrettCom . com
52
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
3.8.5
Installation and User Guide (05/05)
Power Budget Calculations for ES42 Series, Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Magnum products, the following equations should be used:
OPB (Optical Power Budget) = PT(min) - PR(min)
where PT = Transmitter Output Power, and PR = Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125µm (m.m.) is 2.8 dB/km,
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (SSCX)
The following data has been collected from component manufacturer’s (Agilent’s, JDS-
Uniphase, stratus, Lucents’) web sites and catalogs to provide guidance to network
integrators and installers-
www
.
GarrettCom . com
53
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
Fiber
Port
Module
Speed,
Std.
Std. kmWavel Cable X’mitr R’cvr Worst Worst* typical typical*
fdx ength Size Output Sens. OPB, distance OPB, distance
Mode
(hdx) nm
PT , dB PR ,dB dB Km, fdx
dB Km, fdx
µm
ES42-
Multi-
mode (0.4)
2
62.5/125 -20 -31
50/125 -23.5 -31
9.0
5.5
2.5
2.0
14
12
5
4
100Mb
FX
1310
MST, MSC
Single- 20
mode (0.4)
100Mb
FX
ES42-SSC
1310 9/125
-15
-31
14
28
17.5
35
Multi-
mode (0.4)
2
62.5/125 -20
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
100Mb
FX
ES42-
MTRJ
1310
1310
50/125 -23.5 -31
Single-
40
mode
(0.4)
100Mb
FX
9/125
-5
-15
-5
-34
-28
-35
-32
27
54
32.5
65
Long Reach
ES42-LC
Single-
15+
11
22
-
-
100Mb
FX
9/125
1310
1550
mode
Single-
mode
100Mb
FX
ES42-
SSCX
100
9/125
9/125
28
14
112
28
-
-
-
-
Single-
20
100Mb
FX
GarrettCom com
-16
ES42-SFC
1310
mode
(0.4)
www
.
.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed
over long distances (i.e., over approx. 400 meters) can be achieved only if the following
factors are both applied:
•
•
The 100Mb fiber segment must operate in full-duplex (FDX) mode, and
The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)
3.8.6
Connections to NICs which support Auto-Negotiation, RJ-45 ports
The copper ports of Magnum ES42-Sereis Edge Switches will function properly
with NICs (Network Interface Cards) which support Auto-Negotiation, and the Fast Link
Pulse (FLP) coding for the 100BASE-TX signaling system. When connecting a NIC to the
ES42-Series, it may be necessary to reload the NIC drivers on the user device if the NIC
has been communicating with a protocol other than 100BASE-TX (such as 10BASE-T).
When 100Mb operation is agreed and in use, the 10/100 LED is illuminated steady ON and
is OFF, if 10 Mbps traffic.
www
.
GarrettCom . com
55
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
4.0 OPERATION
Installation and User Guide (05/05)
4.1 Dual-Speed Functionality, and Switching
The Magnum ES42 Series Edge Switches provide SIX switched ports
with combination of fiber and copper or copper only. The architecture supports a dual
speed switching environment, with standard auto-negotiation capability.
The switched RJ-45 ports are full- or half-duplex auto-sensing for mode and
speed, and auto-cross for plug polarity. (See Section 4.2). When the connected device is 10
Mbps, the ES42s obeys all the rules of 10 Mbps Ethernet configurations. The 10 Mbps
users can “communicate” with 100Mbps users as well as other 10 Mbps users through the
switch. Similarly, the 100Mbps traffic obeys the rules of 100Mbps Ethernet, and can
communicate with 10 Mb and 100Mb users. Magnum ES42 Series units are plug-and-play
www
.
GarrettCom . com
56
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
devices. There is no software configuring to be done at installation or for maintenance,
even for the LLL ports. The internal functions of both are described below.
Switching, Filtering and Forwarding
Each time a packet arrives on one of the switched ports, the decision is taken to either filter
or to forward the packet. Packets whose source and destination addresses lie on the same
port segment will be filtered, constraining them to one port and relieving the rest of the
network from processing them. A packet whose destination address is on another port
segment will be forwarded to the appropriate port, and will not be sent to the other ports
where it is not needed. Packets needed for maintaining the operation of the network (such
as occasional multi-cast packets) are forwarded to all ports. The Magnum ES42 Series Edge
Switches operate in the store-and-forward switching mode, which eliminates bad packets
and enables peak performance to be achieved when there is heavy traffic on the network.
Switching, Address Learning
The Magnum ES42 Series units have address table capacity of 2K node
addresses, and are suitable for use in large networks. They are self-learning, so that as
www
.
GarrettCom . com
57
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
nodes are added or removed or moved from one segment to another, the ES42- Series
switch automatically keeps up with node locations.
An address-aging algorithm causes least-used addresses to fall out in favor of
new frequently-used addresses. To reset the address buffer, cycle power down-and-up.
4.2 Auto-cross (MDIX), Auto-negotiation and Speed-sensing
The RJ-45 ports support auto-cross (MDI or MDIX) in the auto-negotiation
mode according to the IEEE 802.3u standard. No crossover cables are needed on RJ-45
port, when connecting the ES42 to other unmanaged switches, legacy hubs, managed
switches, media-converter etc. Please note that there can be conditions with managed
switches where the switch manager fixes the port settings via software, and the result of
the auto-negotiation is changed in the managed switch by the manager commands. In
such cases, the 10/100 speed or the F/H mode may be affected, but auto-cross in the
ES42 will still work. The auto-cross function cannot be disabled.
When an RJ-45 cable connection is made, and each time LINK is enabled,
auto-negotiation takes place (except for legacy products, which do not have auto-
negotiation and which go to the default state accordingly). The Magnum ES42 Switch
advertises its capability for 10 or 100 Mbps speed and F/H duplex mode, and the device
www
.
GarrettCom . com
58
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
at the other end of the cable should similarly advertise / respond. Both sides will agree
to the speed and mode to be used per the IEEE 802.3u standard. Depending upon the
devices connected, this will result in agreement to operate at either 10 Mbps or
100Mbps speed, and full- or half-duplex mode.
www
.
GarrettCom . com
59
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
4.3 Dual LEDs, Front-panel and side-panel (Magnum ES42 Series)
LED
Description
PWR
Illuminates GREEN to indicate power applied.
LK/ ACT Steady ON for LINK w/no traffic, blinking for activity per port. LINK will turn
off in the event connectivity is lost between the ends of the twisted pair segment
or a loss of power occurs in the unit or remote device. The Link ports are also
represented by LA1, LA2, LA3…LA6. (Steady On or steady Off indicates no
Receive Activity).
10/100 Steady ON for 100Mb speed, OFF for 10Mb speed per port (copper ports)
F/H (FH1, FH2) Steady ON for Full duplex (F/D) mode, OFF for Half duplex (H/D)
mode per port (For fiber port only)
NOTE: The port#1 and 2 is being assigned for copper or fiber port for different models. On
all copper 10/100 ports model (e.g ES42-d), the LEDs 10 or 100 denotes for
copper port only. For the model 4copper +2 fiber or 5copper +1fiber,(e.g ES42H-
ff-Hd) the F or H denotes for fiber port only.
www
.
GarrettCom . com
60
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
4.4 Hardware operated Alarm Contact for monitoring internal power supply
The two screws Alarm Contacts feature, standard on Magnum ES42H and P,
provides Normally Closed (NC) contacts to which the user can attach one sets of status
monitoring wires at the green terminal block. When this option is present, the terminal
block for Alarm Contacts is part of the Power Input panel in the Magnum ES42s case. The
DC power input connection is in the same panel.
The NC Alarm Contact is held close
when there is power on the main board inside of the
ES42. This provides a “Hardware operated Alarm”
because the NC contacts will open when internal
power is lost, either from an external power down
condition or by the failure of the power supply inside
of the Magnum ES42 Switch.
Useful info about Alarm Contacts in
ES42H and ES42P:
www
.
GarrettCom . com
61
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
1. Two-position terminal block (1,2) provided next to the DC power input, as shown above.
2. The Alarm Relay contact connected to the two terminals (1,2) is hardware operated.
3. By default it is NC (normally closed). It will open if there is any loss of power to the
electronics inside of the unit.
5.0
TROUBLESHOOTING
All Magnum Ethernet products are designed to provide reliability and
consistently high performance in all network environments. The installation of Magnum
ES42 Series 10/100 Mb/s Switches is a straightforward procedure (see INSTALLATION,
Section 3.0); the operation is also straightforward and is discussed in Section 4.
Should problems develop during installation or operation, this section is intended
to help locate, identify and correct these types of problems. Please follow the suggestions
listed below prior to contacting your supplier. However, if you are unsure of the
www
.
GarrettCom . com
62
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
procedures described in this section or if the Magnum ES42 Series 10/100 Mb/s Switch is
not performing as expected, do not attempt to repair the unit; instead contact your supplier
for assistance or contact GarrettCom Customer Support.
5.1 Before Calling for Assistance
1.
If difficulty is encountered when installing or operating the unit, refer back
to the Installation Section of the applicable chapter of this manual. Also
check to make sure that the various components of the network are
interoperable.
2.
Check the cables and connectors to ensure that they have been properly
connected and the cables/wires have not been crimped or in some way
impaired during installation. (About 90% of network downtime can be
attributed to wiring and connector problems.)
www
.
GarrettCom . com
63
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
3.
If the fiber port does not link up while connecting to other device, do a quick
Loop test to test the fiber transceiver is functional or not. Use a short patch
cable of fiber and connect one end of cable to transmit and other end of
receive to the fiber port transceiver. If the Link Led turns solid green, then
the fiber port is functional and working.
4.
5.
Make sure that an AC power cord is properly attached to each Magnum
ES42-Series unit. Be certain that the AC power cord is plugged into a
functioning and appropriate electrical outlet. Use the PWR LEDs to verify
each unit is receiving power.
If the problem is isolated to a network device other than the Magnum
ES42 Series 10/100 Mb/s switch product, it is recommended that
the problem device is replaced with a known good device. Verify whether or
not the problem is corrected. If not, go to Step 6 below. If the problem is
www
.
GarrettCom . com
64
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
corrected, the Magnum ES42 Series Switch and its associated
cables are functioning properly.
6.
If the problem continues after completing Step 5 above, contact your supplier
of the Magnum ES42 Series 10/100 Mb/s Switch unit or if
unknown, contact GarrettCom, Inc by fax, phone or email -
5.2 When Calling for Assistance
Please be prepared to provide the following information.
1.
A complete description of the problem, including the following points:
a. The nature and duration of the problem;
b. Situations/Environment when the problem occurs;
c. The components/devices involved in the problem;
d. Any particular application that, when used, appears to create the problem;
www
.
GarrettCom . com
65
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
2.
An accurate list of GarrettCom product model(s)involved, with serial number(s).
Include the date(s) that you purchased the products from your supplier.
3.
It is useful to include other network equipment models and related hardware,
including Convenient computers, workstations, terminals and printers; plus, the
various network media types being used, along with diagram of network setup.
4.
A record of changes that have been made to your network configuration prior
to the occurrence of the problem. Any changes to system administration
procedures should all be noted in this record.
5.3 Return Material Authorization (RMA) Procedure
All returns for repair must be accompanied by a Return Material Authorization
(RMA) number. To obtain an RMA number, please use this URL -
www
.
GarrettCom . com
66
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
https://rma.garrettcom.com/rma/rma_request_noaccount.php to fill out the form.
Please have the following information readily available:
Name and phone number of your contact person.
Name of your company / institution
Your shipping address
Product name
Serial Number (or Invoice Number)
Packing List Number (or Sales Order Number)
Date of installation
Failure symptoms, including a full description of the problem.
GarrettCom will carefully test and evaluate all returned products, will repair products that
are under warranty at no charge, and will return the warranty-repaired units to the sender
www
.
GarrettCom . com
67
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
with shipping charges prepaid (see Warranty Information, Appendix A, for complete
details). However, if the problem or condition causing the return cannot be duplicated by
GarrettCom, the unit will be returned as:
No Problem Found.
GarrettCom reserves the right to charge for the testing of non-defective units
under warranty. Testing and repair of product that is not under warranty will result in a
customer (user) charge.
5.4 Shipping and Packaging Information
Should you need to ship the unit back to GarrettCom, please follow these instructions:
1. Package the unit carefully. It is recommended that you use the original
container if available. Units should be wrapped in a "bubble-wrap" plastic sheet
www
.
GarrettCom . com
68
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
or bag for shipping protection. (You may retain all connectors and this
Installation Guide.)
CAUTION: Do not pack the unit in Styrofoam "popcorn" type packing material.
This material may cause electro-static shock damage to the unit.
2. Clearly mark the Return Material Authorization (RMA) number on the
outside of the shipping container.
3. GarrettCom is not responsible for your return shipping charges.
4. Ship the package to:
GarrettCom, Inc.
47823 Westinghouse Dr.
Fremont, CA 94539
Attn.: Customer Service
www
.
GarrettCom . com
69
Download from Www.Somanuals.com. All Manuals Search And Download.
ES42 Series Edge Switches
Installation and User Guide (05/05)
APPENDIX A: WARRANTY INFORMATION
GarrettCom, Inc. warrants its products to be free from defects in materials and
workmanship for a period of three (3) years from the date of shipment by GarrettCom.
During this warranty period, GarrettCom will repair or, at its option, replace components in
the products that prove to be defective at no charge other than shipping and handling,
provided that the product is returned pre-paid to GarrettCom.
This warranty will not be effective if, in the opinion of GarrettCom, the product
has been damaged by misuse, misapplication, or as a result of service or modification other
than by GarrettCom. GarrettCom reserves the right to make a charge for handling and
inspecting any product returned for warranty repair which turns out not to be faulty.
Please complete the warranty card as this acts as a product registration, and mail
it to GarrettCom within two weeks of your purchase.
www
.
GarrettCom . com
70
Download from Www.Somanuals.com. All Manuals Search And Download.
|