Installation
Instructions
Indoor Direct Vent Tankless Water Heater
Models GN75DNSRSA, GN94DNSRSA, GP94DNSRSA
FOR INDOOR APPLICATIONS ONLY
Questions? Call 888.HOTWTER (888.468.9837) or Visit our website at ge.com
WARNING:
Read entire manual. Failure to follow all guides and rules could cause personal
injury or property damage.
• Check with your state and/or local public works department for plumbing codes. You must follow their
guides as you install the Water Heater.
NOTE: Failure to comply with these installation instructions will void the product warranty, and the
installer will be responsible for any service, repair or damages caused thereby.
BEFORE BEGINNING INSTALLATION
SAFETY PRECAUTIONS
Read these instructions completely and carefully.
WARNING:
If the information in these
instructions is not followed exactly, a fire or explosion
may result, causing property damage, personal injury
or death.
•
IMPORTANT — Save these instructions
for local inspector’s use.
•
IMPORTANT — Observe all governing
codes and ordinances.
FOR YOUR SAFETY!
• Note to Installer – Be sure to leave these
– Do not store or use gasoline or other
flammable vapors or liquids or other
combustible materials in the vicinity of this
or any other appliance. To do so may result
in an explosion or fire.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
instructions with the Consumer.
• Note to Consumer – Keep these instructions
for future reference.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation
is not covered under the Warranty.
• Do not touch any electrical switch;
do not use any phone in your building.
Recognize this symbol as an indication
of Important Safety Information!
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier,
call the fire department.
• Do not return to your home until authorized
by the gas supplier or fire department.
– Improper installation, adjustment, alteration,
service or maintenance can cause property
damage, personal injury or death. Refer to
this manual. Installation and service must
be performed by a qualified installer, service
agency or the gas supplier.
• This water heater must be vented outdoors
using approved ducting materials.
• Service information and wiring diagram are
located behind front panel.
• Service must be performed by a qualified
service agency.
• This appliance must be properly grounded and
installed as described in these instructions
.
49-50229-1 03-08 JR
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PARTS PROVIDED
Locate the parts packed with the Water Heater.
4 #10 x 11⁄4″
Wood Screws
Gas Valve 3/4″ FNPT Ball Valve
TOOLS YOU WILL NEED
OTHER TOOLS THAT MIGHT BE REQUIRED
• Pipe Wrenches (2)
• Adjustable Pliers
• Screwdrivers (2)
• Wire Cutters
• Gloves
• Safety Glasses
• Hammer Drill with Concrete Bits
• Saw
• Threading Machine with Heads and Oiler
• Core Drill with Diamond Head
• Torch Set
• Copper Tubing Cutter
• Steel Pipe Cutter
MATERIALS YOU WILL NEED TO SUPPLY
• Soap Solution
• Pipe Fittings Required:
• Pipe Compound
• Approved Venting
– Unions
– Ball Valves
– Drain Valves
– Pressure Relief Valve
OTHER MATERIALS THAT MIGHT BE NEEDED
• Heat Tape
• Pipe Insulation
• 5/8″ ID PVC Flexible
Tubing
• 2 Conductor 22 AWG Wire for Remote Control
• Single Gang Electrical Box
• Wire Nuts
• Electrical Wire and Conduit per Local Code
• Air Inlet Screen
• Optional Pipe Cover AGTPCM
• Optional Remote Controller AGTRC1
• Concrete Wall Anchors (Optional)
Your installation components may vary.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
DIMENSIONS
A
B
H
E
G
I
F
J
C
D
K
GN75/GN94/GP94DNSRSA
IN. (MM)
DIM.
DESCRIPTION
A
B
C
D
E
F
G
H
I
Width
14 (355.6)
95⁄8 (244.5)*
227⁄8 (582)
251⁄2 (647.7)
35⁄8 (91)*
45⁄16 (110)
213⁄16 (70)*
11⁄8 (27)
Depth
Height – Unit
Height – with brackets
Hot Water Outlet – from wall
Hot Water Outlet – from center
Cold Water Inlet – from wall
Cold Water Inlet – from center
Gas Connection – from wall
Gas Connection – from center
From base to gas connection
From base to cold connection
From base to hot connection
37⁄8 (99)*
31⁄2 (89)
15⁄8 (40)
J
K
2 (50)
15⁄8 (41)
*This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm).
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PLANNING FOR VENTING
INTAKE/EXHAUST GUIDELINES
Refer to the specific instructions on your vent
product for additional installation requirements.
• Venting should be as direct as possible with
a minimum number of pipe fittings.
• This water heater is a direct vent water heater and
therefore is certified and listed with the vent system.
You must use vent components that are certified
and listed with the water heater model. See
approved venting list on page 20.
• Vent diameter must not be reduced.
• Do not connect the venting system with
an existing vent or chimney.
• Do not connect vent with the vent pipe of any other
water heater or appliance.
• Do not combine vent components from different
manufacturers.
• Vent connections must be firmly pressed together
so that the gaskets form an air-tight seal.
• The vent system must vent directly to
the outside of the building and use outside
air for combustion.
• The vent piece connected to the water heater must
be secured with one self-tapping screw.
• Every vent connection must be accessible for
inspection, cleaning and replacement.
• Refer to the vent pipe manufacturer’s instructions
for component assembly instructions.
• Avoid dips or sags in horizontal vent runs by
installing supports per the vent manufacturer’s
instructions.
• It is recommended to install an optional inlet screen
to minimize blockage and maintenance from debris.
See page 20.
• Support horizontal vent runs every four feet
and all vertical vent runs every six feet or in
accordance with local codes.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
FLUE TERMINAL CLEARANCES
U.S. INSTALLATIONS
CLEARANCES PER
ANSI Z21.10.3
36 inches (91 cm)
12 inches (30 cm)
REF
A
B
DESCRIPTION
Clearance above grade, veranda, porch, deck or snowline
Clearance to window or door that may be opened
Clearance to permanently closed window
C
*
*
D
Vertical clearance to ventilated soffit, located above the terminal within
a horizontal distance of 2 feet (61 cm) from the center line of the terminal
E
F
G
H
Clearance to unventilated soffit
Clearance to outside corner
Clearance to inside corner
Clearance to each side of center line extended above meter/regulator
assembly
*
*
*
*
I
Clearance to service regulator vent outlet
*
J
Clearance to nonmechanical air supply inlet to building or
the combustion air inlet to any other appliance
12 inches (30 cm)
K
Clearance to a mechanical air supply inlet
3 feet (91 cm) above
if within 10 feet
(3 m) horizontally
L
M
Clearance above paved sidewalk or paved driveway located on public property1
Clearance under veranda, porch, deck or balcony2
*
*
*For clearances not specified in ANSI Z223.1/NFPA 54, clearances are in accordance with local installation codes and the requirements of the gas supplier.
Clearance to opposite wall is 24 inches (60 cm).
1 A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
2 Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor.
FLUE TERMINAL CLEARANCES (ANSI Z21.10.3 • CSA 4.3)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
ADDITIONAL CLEARANCES – VENT TERMINAL
These clearances are applicable to both concentric terminations and nonconcentric vent exhaust terminations.
Local codes supersede these clearances.
• Avoid termination locations near a dryer vent.
• Avoid termination locations near commercial cooking exhaust.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
FLUE INSTALLATION – CONDENSATE DRAIN
HORIZONTAL TERMINATION WITH
A CONDENSATE DRAIN
VERTICAL TERMINATION (condensate collector
required in all installations)
3 in (75 mm)
minimum
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
PLANNING FOR PLUMBING
(shown with optional pipe cover)
Optional Pipe Cover
(AGTPCM) shown shaded.
Pipe cover not required,
However, consideration
should be taken in
Unit
the design of the rough
plumbing to allow
installation of unit
and pipe cover.
61⁄2″
7″
12″
Suggested area for
12″
Water and Gas lines to
come through the wall
so the optional pipe
cover can be installed,
if desired.
41⁄2″
Water
through
the wall
18″ min.
97⁄8″
33⁄8″
Gas
21⁄2″
9″
21⁄2″
21⁄2″
21⁄2″
Water and Gas
from below
6″
Floor
12″
The center of the pipes can be placed anywhere
within the shaded area. The center of the pipes
is recommended to be protruding only within 6″
of the mounting wall. Other specific installations
may be different.
CAUTION:
Hot Water outlet pipes leaving unit
can be hot to touch. Insulation must be used for hot
water pipes below 36″ due to burn risk to children.
NOTE: It is recommended to install the bottom
of the unit at least 18″ off the ground to minimize
blockage and maintenance from debris and provide
room for the optional Pipe Cover Accessory Model
Number AGTPCM.
Be sure that the minimum elevation of the bottom
of the unit is 16″ to meet the 36″ recommended
clearance for the exhaust.
CAUTION:
BURN HAZARD. Hot exhaust and
NOTE: Do not install electrical outlet directly
below unit. Electrical outlet must be installed
less than 6 feet from unit.
vent may cause serious burns. Keep back from water
heater unit. Keep small children and animals away
from unit.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CLEARANCES FOR WATER HEATER
MOUNTING THE WATER HEATER
WARNING:
Combustible
CAUTION:
Reinforcement of the
construction refers to adjacent walls and ceiling
and should not be confused with combustible or
flammable products and materials. Combustible
and/or flammable products and materials should
never be stored in the vicinity of this or any gas
appliance.
wall is required in case the wall is not strong
enough to hold the water heater. Do not mount
to drywall unless mounting screws are secured
in wall studs.
Make sure the location of the water heater allows
for easy access and operation.
To top
Wall studs should be utilized when mounting the
water heater to the wall. On masonry or concrete
wall, use concrete anchors or lag bolts.
Identify the installation location and confirm
that the installation will meet all required
clearances. Use mounting template
1
To side
to locate screw and anchor locations.
Securely attach the water heater to the wall
using the brackets located at the top and
bottom of the water heater.
2
3
To front
To floor/ground
Ensure that the attachment strength is
sufficient to support the weight. Refer to the
weight of the water heater in the Specification
Guidelines. Four mounting screws with 200 lb.
tensile load capability are required at
a minimum.
To combustibles
6 inches (152 mm)
To noncombustibles
2 inches (51 mm)
0 (zero)
6 inches (152 mm)
1/8 inch (3 mm)
12 inches (305 mm)
0 (zero)
Top of heater
Back of heater 0 (zero)
Front of heater 6 inches (152 mm)
Sides of heater 2 inches (51 mm)
Floor/ground
Vent
12 inches (305 mm)
0 (zero)
Closet
6 inches (152 mm)
from front
6 inches (152 mm)
from front
Wall installation
brackets
*Every vent connection must be accessible for inspection, cleaning
and replacement.
CORROSIVE ATMOSPHERES
NOTICE: The water heater or intake air supply
should not be installed near an air supply
containing halogenated hydrocarbons
or near swimming pool chemicals.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MOUNTING THE WATER HEATER (cont.)
MOUNTING THE WATER HEATER (cont.)
FINISHED WALLS (Drywall) Option 1:
ON MASONRY OR CEMENT WALL: Mount
4 wall anchors (not supplied) in a wall suitable
to carry 200 lbs minimum tensile load each.
Level the unit during installation.
IMPORTANT: Anchors suitable for masonry
or concrete are to be supplied by the installer.
4
Mount boards over drywall directly to studs
in the wall. When attaching the unit to a finished
wall, mount two boards suitable for anchoring
to wall studs. Level the unit during installation.
NOTE: Do not hang the unit on drywall only. The
unit must be secured into wood mounting board.
243⁄4″
Boards on outside of finished wall
FINISHED WALLS (Drywall) Option 2:
Framed wall with boards behind the drywall.
Mount the unit to boards in the wall. Do not use
the screws provided to mount through drywall.
Screws long enough to penetrate the drywall
and provide at least 1″ of engagement in wood
should be used. Screws should be rated to carry
a tensile load of 200 lbs each. Level the unit
during installation.
243⁄4″
Boards on inside of finished wall
NOTES:
• Screws provided must fasten securely
and directly into wood. If screws go through
drywall and do not fully engage the wood stud,
the installer must supply correct screws.
• Do not hang the unit on drywall only. The unit
must be secured into wood mounting board.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CONNECTING THE WATER HEATER TO GAS AND WATER
GAS PIPING
GAS PIPING (cont.)
1
1
GENERAL INSTRUCTIONS
PIPE SIZING PROCEDURE
• Make sure gas supply is off prior to making
any connections to the water heater. A manual
gas control valve, provided with this water
heater, must be placed in the gas supply line
to the water heater. A union can be used on
the connection above the shut-off valve for
the future servicing or disconnection of the unit.
The gas supply to the home must be capable
of handling the entire gas load of the home,
calculated by adding the BTU rating of each gas
appliance in the home. State and local codes must
be met, as well as utility requirements, to ensure
gas supply to the unit is adequate to meet the
rated demand. Use the charts below as a guide to
size the pipe from the utility meter to the tankless
water heater. Gas line sizing is based on gas type,
the pressure drop in the system, the gas pressure
supplied and the gas line type. Refer to the National
Fuel Gas Code, NFPA 54, and/or your local gas
provider, for proper gas line sizing.
• Check the type of gas and the gas inlet pressure
before connecting the water heater. If the water
heater is not of the gas type that the building is
supplied with, DO NOT connect the water heater.
Contact the dealer for the proper unit to match
the gas type.
PIPE SIZING TABLE – NATURAL GAS
• Check the gas supply pressure immediately
upstream at a location provided by the gas
company. Supplied gas pressure must be within
the limits shown in the Specifications section.
cubic feet per hour
Schedule 40 Metallic Pipe
Inlet Pressure:
less than 2 psi (55 inches W.C.)
Pressure Drop: 0.3 inches W.C.
Specific Gravity: 0.60
• Before placing the appliance in operation, all
joints, including the heater, must be checked for
gas tightness by means of leak detector solution,
soap and water or an equivalent nonflammable
solution, as applicable. (Since some leak test
solutions, including soap and water, may cause
corrosion or stress cracking, the piping shall
be rinsed with water after testing, unless it has
been determined that the leak test solution is
noncorrosive.)
PIPE SIZE (INCHES)
1
Length
3/4
11/4
11/2
10
20
273
188
151
129
114
104
95
89
83
79
70
514
353
284
243
215
195
179
167
157
148
131
119
109
102
1060
726
583
499
442
400
368
343
322
304
269
244
224
209
1580
1090
873
747
662
600
552
514
482
455
403
366
336
313
30
40
50
60
70
80
90
100
125
150
175
200
• Always use approved connectors to connect the
unit to the gas line. Always purge the gas line of
any debris before connection to the water heater.
63
58
54
• The gas supply line shall be gas tight, sized
and so installed as to provide a supply of gas
sufficient to meet the maximum demand of the
heater and all other gas-consuming appliances
at the location without loss of pressure.
PIPE SIZING TABLE – PROPANE GAS
cubic feet per hour
Schedule 40 Metallic Pipe
Inlet Pressure: 11.0 inches W.C.
Pressure Drop: 0.5 inches W.C.
Specific Gravity: 1.50
• Any compound used on the threaded joint of
the gas piping shall be a type which resists the
action of liquefied petroleum gas (propane/LPG).
PIPE SIZE (INCHES)
Length
1/2
3/4
1
11/4
10
20
291
200
160
137
122
110
101
94
89
84
74
67
608
418
336
287
255
231
212
197
185
175
155
140
1150
787
632
541
480
434
400
372
349
330
292
265
2350
1620
1300
1110
985
892
821
763
716
677
600
• Refer to an approved pipe sizing chart
30
if in doubt about the size of the gas line.
40
50
60
80
100
125
150
175
200
543
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CONNECTING THE WATER HEATER
TO THE GAS SUPPLY
2
Connect the gas supply to the system following
state and local plumbing codes. Use the supplied
ball valve at the inlet to the system. Make sure
the gas supply line to the water heater fits in the
diagram shown on page 9. This is essential if a pipe
cover accessory (model number AGTPCM) is to be
installed.
IMPORTANT: Use a pipe wrench to securely
hold on to the end of the water heater gas inlet
to prevent twisting the inlet.
IMPORTANT: Leave the gas valve off until
instructed to turn it on.
Gas Pressure Test Port
Gas Shut Off Valve
Gas Supply
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CONNECTING THE WATER HEATER TO GAS AND WATER (cont.)
WATER PIPING
WATER PIPING (cont.)
3
3
GENERAL INSTRUCTIONS
PRESSURE RELIEF VALVE (cont.)
• The water supply should be shut off while
connecting the water heater. Make sure the
water inlet and outlet lines to the water heater fit
in the diagram shown on page 9. A manual water
control valve must be placed in the water inlet
connection to the water heater before it is
connected to the water line. Unions can be
used on both the hot and cold water lines for
future servicing and disconnection of the unit.
• The relief valve must be rated up to 150 psi and
to at least the maximum BTU/hr of the appliance.
• The discharge from the pressure relief valve
should be piped to the ground or into a drain
system to prevent exposure or possible burn
hazards to humans or other plant or animal life.
Follow local codes. Water discharged from the
relief valve could cause severe burns instantly,
scalds or death.
• The piping (including soldering materials) and
components connected to this appliance must
be approved for use in potable water systems.
• The pressure relief valve must be manually
operated once a year to check for correct
operation.
• Purge the water line to remove all debris and air.
Debris will damage the water heater.
• The relief valve should be added to the hot water
outlet line according to the manufacturer’s
instructions. DO NOT place any other type of
valve or shut-off device between the relief valve
and the water heater.
• Toxic chemicals such as those used for boiler
water treatment are not to be introduced to the
potable water used for space heating.
• If the appliance will be used as a potable water
source, it must not be connected to a system
that was previously used with a nonpotable
water heating appliance.
• Do not plug the relief valve and do not install any
reducing fittings or other restrictions in the relief
line. The relief line should allow for complete
drainage of the valve and the line.
• Ensure that the water filter on the water heater
is clean and installed. See the Cleaning the inlet
filter section in the checklist on page 23.
• If a relief valve discharges periodically, this may
be due to thermal expansion in a closed water
supply system. Contact the water supplier or
local plumbing inspector on how to correct this
situation. Do not plug the relief valve.
• New plumbing typically has contamination
in the lines. The inlet water filter should be
cleaned immediately after initial use.
• Neither GE nor the American National Standard
(ANSI Z21.10.3)/Canadian Standard (CSA 4.3)
requires a combination temperature and
pressure relief valve for this appliance; however,
local codes may require a combination
CAUTION:
Hot Water outlet pipes leaving
unit can be hot to touch. Insulation must be used
for hot water pipes below 36″ due to burn risk to
children.
temperature and pressure relief valve.
PRESSURE RELIEF VALVE
INTERNAL BUILT-IN FREEZER PROTECTION
• Make sure the pressure relief valve is installed
so there is clearance if the optional pipe cover
(AGTPCM) is installed.
• The freeze protection features include
electrical heating elements and intermittent firing
of the burner. Freeze protection may be disabled
if electricity or gas is not supplied, or if there is
an error preventing the water heater from
functioning.
• An approved pressure relief valve is required
by the American National Standard (ANSI
Z21.10.3)/Canadian Standard (CSA 4.3)
for all water heating systems.
NOTE: See SUPPLEMENTAL FREEZE PROTECTION
on page 15.
• The relief valve must comply with the standard
for Relief Valves and Automatic Gas Shutoff
Devices for Hot Water Supply Systems (ANSI
Z21.22) and/or the standard Temperature,
Pressure, Temperature and Pressure Relief
Valves and Vacuum Relief Valves, CAN1-4.4.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
CONNECTING THE WATER HEATER
TO THE WATER SUPPLY
SUPPLEMENTAL FREEZE PROTECTION
If the unit is installed in an environment that can
freeze, follow state and local codes and apply heat
trace to ALL water pipe and fittings located outside
(attic, crawl space or building structure).
It is highly recommended in areas where freezing
temperatures occur to install automatic drain
valves that work in the event of a power loss.
Refer to the diagram in the FREEZE PROTECTION
FOR EXTERNAL PIPING section (page 17). These
valves should be wired to a supply current.
In the event of a power loss, the system will
drain automatically. Be sure to test this system
after installation by turning off power to ensure
the system drains properly.
Hot Outlet
Shut Off Valve
Cold Inlet
Shut Off Valve
Pressure Relief
Valve
Water connections to the tankless water heater
should follow all state and local plumbing codes.
If this is a standard installation, refer to
the diagram on the following page under
RECOMMENDED PIPING FOR BASIC INSTALLATION.
If freeze protection valves are being installed, refer
to the diagram under FREEZE PROTECTION FOR
EXTERNAL PIPING on page 17.
1. Plumb water supply to the tankless water heater
on the 3/4″ MNPT connection at the bottom of
the unit marked WATER INLET.
2. Plumb the home hot water supply to the 3/4″
MNPT connection marked WATER OUTLET
at the bottom of the unit.
NOTE: Make sure water lines to the water heater fit
in the diagram shown on page 9. This is essential if
a pipe cover accessory (model number AGTPCM) is
to be installed.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
RECOMMENDED PIPING FOR BASIC INSTALLATION
NOTE: If unit is installed in an
environment that can freeze, follow
state and local codes and apply
heat trace to ALL water pipes and
fittings located outside (attic, crawl
space or building structure).
KEY
This is not an engineered drawing; it is intended
only as a guide and not as a replacement for
professionally engineered project drawings. This
drawing is not intended to describe a complete
system; it is up to the contractor/engineer to
determine the necessary components for and
configuration of the particular system being
installed. The drawing does not imply compliance
with local building code requirements; it is the
engineer‘s/contractor’s responsibility to ensure
the installation is in accordance with all local
building codes. Confer with local building officials
before installation.
Pressure Relief Valve
Boiler Drain Valve
3/4″ Ball Valve
3/4″ Union
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
FREEZE PROTECTION
FOR EXTERNAL PIPING
IMPORTANT!
With electrical power supplied to the water
heater, it will not freeze in environments as
cold as -30°F, when protected from direct wind
exposure.
In the event of a power failure at temperatures
below freezing, the water heater should be
drained of all water to prevent freezing damage.
The unit may be drained manually, or through
the installation of the optional solenoid valves
as shown.
The unit may be drained manually; however, we
highly recommend that drain-down solenoid valves
be installed that will automatically drain the unit if
power is lost.
When the electrical power to the water heater
fails, the 3/4″ solenoid valve closes (stopping
the flow of water into the heater) and the 1/4″
solenoid valve opens (allowing the water heater
and associated piping to drain). Ensure that you
run the drain for the solenoids to the outside
environment to prevent discharging water inside
the building, which can cause water damage.
NOTE: If the unit is installed in an environment that
can freeze, follow state and local codes and apply
heat trace to ALL water pipes and fittings located
outside (attic, crawl space or building structure).
KEY
This is not an engineered drawing; it is intended
only as a guide and not as a replacement for
professionally engineered project drawings. This
drawing is not intended to describe a complete
system; it is up to the contractor/engineer to
determine the necessary components for and
configuration of the particular system being
installed. The drawing does not imply compliance
with local building code requirements; it is the
engineer‘s/contractor’s responsibility to ensure
the installation is in accordance with all local
building codes. Confer with local building officials
before installation.
Pressure Regulator
3/4″ Ball Valve
Circulating Pump
Boiler Drain Valve
3/4″ Union
Check Valve
Pressure Relief Valve
Solenoid Valve
S
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
ELECTRICAL CONNECTION
INFORMATION
WARNING –
To reduce the risk
of fire, electrical shock and personal injury:
• Do not use an extension cord or an adapter plug
with this appliance.
• The water heater must be electrically grounded
in accordance with local codes and ordinances
or, in the absence of local codes, in accordance
with the NATIONAL ELECTRICAL CODE, ANSI/NFPA
NO. 70, or the CANADIAN ELECTRICAL CODE,
CSA C22.1.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz,
and connected to a properly grounded branch
circuit, protected by a 15- or 20-amp circuit
breaker or time-delay fuse.
If electrical supply provided does not meet the
above specifications, it is recommended that a
licensed electrician install an approved outlet.
WARNING –
This water heater is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should
be plugged directly into a properly grounded
three-prong receptacle. Do not cut or remove
the grounding terminal from this plug.
ENSURE PROPER GROUND EXISTS BEFORE USE.
DO NOT REMOVE GROUND PRONG.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
VENTING INSTRUCTIONS
VENTING INSTRUCTIONS (cont.)
Refer to the specific instructions on your vent
product for additional installation requirements.
MAXIMUM VENT LENGTH
Maximum System performance is achieved
at a vent length of 21 equivalent feet or less. The
system is capable of 41 equivalent feet vent length
if required, but this reduces system performance.
For vent length calculation, a 90-degree elbow
counts as 6 feet and a 45-degree elbow counts
as 3 feet.
CONDENSATE
Regions of cold climate will create more
condensate in the vent system.
Condensate formation can even occur in
high-efficiency direct vent appliances. To prevent
condensate damage, follow these instructions:
Determine the number of 90-degree elbows in
the vent system. (Two 45-degree elbows count
as one 90-degree elbow.)
1
• First remove the black plastic cap, and use 5/8″
ID flexible PVC tubing to drain condensate.
Refer to the table to find the maximum vent
length based on the number of elbows.
2
• The condensate trap must contain a minimum
of 3 inches (75 mm) of water. See page 8.
Use the chart below to compute maximum
permissible lengths for venting to outdoors.
• Dispose of condensate per local codes.
• In applications where condensate could freeze,
such as an unconditional attic space, care should
be taken to prevent condensation line freezing.
Refer to state and local codes for proper disposal
of condensate.
NOTE: Factory unit is set to vent up to 21 ft.
for maximum performance. The unit can be
reconfigured to 41 ft. See below or call
1.888.HOTWTER.
VENT LENGTH CALCULATIONS
WARNING:
If the condensate
CONCENTRIC VENT PIECE
Straight
EQUIVALENT LENGTH
1 ft. (per foot length)
collector is not used, the drain pipe must be
capped to prevent exhaust gases and condensate
from entering the building. The cap is supplied on
the appliance.
90-degree elbow
45-degree elbow
6 ft. each
3 ft. each
Total vent length = # straight ft. + # 90-degree
elbow x 6 ft. + # 45-degree elbow x 3 ft.
CAUTION:
Without proper drainage
or disposal, condensate will damage the heat
exchanger. Condensate collector on the unit
must be properly connected.
Switch No.
ON
*
If the length is greater than
21 ft. (6.4 m), then move dip
switch no. 1 (SW1) to OFF.
O
F
F
SW1
1
2
3
4
5
6
7
8
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
VENTING INSTRUCTIONS (cont.)
FLUE INSTALLATION – CONCENTRIC VENTING
To adjust the condensate collector position:
Bracket
Loosen the 4 screws at the rear bracket.
1
2
Slide the bracket away from the female
vent top.
Remove the 4 screws attaching the female vent
top to the water heater.
3
4
5
Lift up the female vent top and reposition as
desired (or replace with a male vent top).
Install the 4 screws at the vent top and tighten
the 4 screws at the bracket.
Secure the first vent component to the water heater
with one self-tapping screw at the hole located above
the condensate collector.
VENTING INSTRUCTIONS
(cont.)
VENT PRODUCTS
Listed and Tested Vent Products for GN75DNSRSA, GN94DNSRSA and GP94DNSRSA (concentric venting)
MANUFACTURER
Ubbink
PRODUCT
Rolux Vent System
Saf-T Vent SC system
PARTS
Refer to the manufacturer’s technical literature
for specific part numbers and instructions.
Heat-Fab
At the time of printing, these manufacturers’
products were listed and tested vent products.
The installer must verify prior to installation if
Metal-Fab
Corr/Guard Vent/
Air Intake System
proper venting is used. For up-to-date approved
for the CSA Certification record with approved vent materials.
VENT MANUFACTURER CONTACT INFORMATION FOR INSTALLATION INSTRUCTIONS AND PARTS LIST
Heat-Fab
Metal-Fab Inc.
Ubbink
Telephone: 1.800.772.0739
Telephone: 888.HOTWTER
(888.468.9837)
Telephone: 1.800.835.2830
1.316.943.2351
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
HIGH ALTITUDE INSTALLATIONS
Set dip switches 2 and 3 to the values shown in the
table below for your altitude. The default setting for
the appliance is 0-2000 ft (0-610 m) with switches
No. 2 and No. 3 in the OFF position.
WARNING:
Do not adjust the other
dip switches unless specifically instructed to do so.
If unsure of the altitude in your location, call
1.888.HOTWTER (888.467.9837).
0–2000 ft.
(0–610 m)
2001–5200 ft.
(610–1585 m)
OFF
5201–7700 ft.
(1585–2347 m)
7701–10200 ft.
(2347–3109 m)
Switch No. 2
Switch No. 3
OFF
ON
ON
OFF
ON
OFF
ON
Switch No.
ON
Switch No.
ON
Switch No.
ON
Switch No.
ON
O
F
F
O
1
F
O
1
F
O
1
F
1
2
3
4
5
6
7
8
F
F
F
2
3
4
5
6
7
8
2
3
4
5
6
7
8
2
3
4
5
6
7
8
CASCADING MULTIPLE WATER HEATERS
The Dual Connect Cable Kit (AGTDC1) is an optional
accessory that connects 2 water heaters and allows
them to function as one hot water source.
GUIDELINES
• Do not install the Dual Connect Cable Kit (AGTDC1)
with the Multi Connect Kit (AGTCK1) and the Multi
Connect Cable Kit (AGTMC1) because they are not
designed to operate together.
The Multi Connect Kit (AGTCK1) and the Multi Connect
Cable Kit (AGTMC1) are optional accessories that
connect 3 to 5 water heaters and allow them to
function as one hot water source.
• Water heaters should be installed less than
18 inches apart so that the cables will reach
between units and to prevent temperature
fluctuations (cold water sandwich effect) when
the water is shut off and turned back on.
Refer to the instructions that come with the accessory
for complete installation information.
• Temperature settings can only be changed on
the controller for the primary unit.
NUMBER OF CONNECTED WATER HEATERS
ACCESSORIES NECESSARY
2
(1) Dual Connect Cable Kit (AGTDC1)
3
4
5
(1) Multi Connect Kit (AGTCK1) and (1) Multi Connect Cable Kit (AGTMC1)
(1) Multi Connect Kit (AGTCK1) and (2) Multi Connect Cable Kits (AGTMC1)
(1) Multi Connect Kit (AGTCK1) and (3) Multi Connect Cable Kits (AGTMC1)
Connecting Two Units
Connecting Five Units
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
REMOTE CONTROLLER INSTALLATION
REMOTE CONTROLLER INSTALLATION
(cont.)
LOCATION
• The controller should
be out of reach of small
children.
MOUNTING THE CONTROLLER
Determine a suitable location for
1
2
3
the controller.
• Avoid locations where
the controller may
become hot (near the
oven or radiant heater).
Mount a single gang outlet box in the wall
where the remote control is indicated.
Run the cable between the controller
and the water heater or the controller
and the other controller.
• Avoid locations in direct
sunlight. The digital
display may be difficult
to read in direct
Remove the face plate from the remote
controller, using a screwdriver.
4
sunlight.
Connect the cable to the remote controller.
5
6
• Avoid locations where the remote controller
could be splashed with liquids.
Mount the controller to the wall in the single
gang outlet box installed in step 2.
• Do not install in locations where it can be
adjusted by the public.
Disconnect the power from the water heater.
Remove the cover of the water heater.
7
8
9
CONFIGURATIONS
Remove the plastic cover from the PCB
and electrical connections.
A maximum of 4 remote controllers can be
installed for a water heater or bank of water
heaters. Controllers can only be wired in parallel.
Controllers cannot be wired in series.
Outline of Remote
If 4 AGTRC1’s are installed, press the Priority and
On/Off buttons on the fourth controller until a beep
sounds.
securing screw
wiring hole
1-21/32"
3-5/16"
securing screw
WARNING:
DO NOT ATTEMPT
TO CONNECT THE REMOTE CONTROLLERS WITH
THE POWER ON.
Thread the cable through the access hole
at the base of the unit and connect the wires
to the controller terminals on the bottom
right-hand side of the PCB.
10
Wire Controllers in Parallel
CABLE LENGTHS AND SIZE
The cable for the remote controller should be
a nonpolarized two-core cable with a minimum
gauge of 22 AWG. The maximum cable length
from each controller to the water heater depends
on the total number of wired controllers connected
to the water heater.
Secure the controller cable using the clamp
provided.
11
NUMBER OF WIRED MAXIMUM CABLE LENGTH FOR EACH
CONTROLLERS
CONTROLLER TO WATER HEATER
328 ft. (100 m)
1
2
164 ft. (50 m)
3 or 4
65 ft. (20 m)
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
REMOTE CONTROLLER INSTALLATION (cont.)
MOUNTING THE CONTROLLER (cont.)
CLEANING THE INLET FILTER (cont.)
Use pressurized air to remove dust from the main
burner, heat exchanger and fan blades. Do not use a
wet cloth or spray cleaners on the burner. Do not use
volatile substances such as benzene and thinners.
They may ignite or fade the paint.
9
Replace the plastic cover over the PCB, and then
12
replace the cover of the water heater.
Use soft dry cloth to wipe cabinet.
Open water valves.
10
11
12
13
Check for leaks.
Connect electrical power and turn on the unit.
INSTALLATION CHECKLIST
• Ensure 120 Volts A.C. is connected to the unit and that
the circuit is turned on.
• Verify the gas system is functioning correctly by
connecting your manometer to the gas pressure test port
on the unit (see page 13). Operate all gas appliances in
the facility. The inlet gas pressure on the unit MUST NOT
DROP BELOW that listed on the unit rating plate for the
gas type being used. A manometer can be used to check
the pressure.
• Make sure you have cleaned the COLD water inlet filter
screen.
• Inspect HOT (outlet) and COLD (inlet) water lines to ensure
they have not been crossed and are leak-free.
• Ensure the manual gas valve packaged with the water
heater is installed in the gas supply line (see page 12).
• Ensure the controller is installed and functioning.
Instruct the consumer on how to operate the controller.
Instructions are always supplied in the Owner’s Manual
(see page 22). A typical water temperature set point
is 120 degrees.
• Explain to the customer the importance of never
blocking the vent ducting, intake and exhaust.
Never store anything around the vent exhaust.
• Ensure you have used the correct venting products
for the model installed and that you have completely
followed the venting installation instructions
(see pages 19–20).
• Ensure the condensate collector drain on the unit
is installed to allow condensation to drain away from
the water heater to a proper drain source (see page 8).
• The vent system should not exceed the maximum length
for the number of elbows used. Refer to the venting
maximum length chart on page 19. Apply the vent
temperature caution label to the vent terminal located
outside the home.
CLEANING THE INLET FILTER
It is imperative that
Water inlet
control compartments,
burners and circulating
air passageways of the
appliance be kept clean.
Water inlet
filter
CAUTION:
Before
performing this action, first
remove power to the water
heater and be sure not to
stand near the discharge
line of the pressure relief
NOTE: View shown
is from under the unit.
valve. This will prevent a possible scald injury
.
Turn off and disconnect electrical power. Allow water
heater to cool.
1
Shut off water inlet.
2
3
4
5
Open hot water tap at nearest faucet.
Close outlet valve on unit.
Have a small pan or bucket ready to catch spilled
water.
Remove and clean the water inlet filter with a small
brush. If scale is present, clean in a white vinegar
solution.
6
Replace water inlet filter.
7
8
Remove the front panel by removing 4 screws.
• For instructions on operating the unit,
refer to the Owner’s Manual.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
TECHNICAL DATA
PRESSURE DROP CURVE
GN75
GN94/GP94
OUTLET FLOW DATA
GN94/GP94
GN75
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
LADDER DIAGRAM
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
28
Download from Www.Somanuals.com. All Manuals Search And Download.
|