				F485 COMMUNICATIONS CONVERTER   
					Page 3 of 8   
					FEATURES   
					• 
					• 
					• 
					• 
					Converts between RS232, RS485 or Fiber   
					1200 to 57600 baud rates   
					Isolated RS485 interface   
					50/125µm, 62.5/125µm, and 100/140µm fiber   
					sizes   
					• 
					Front panel LEDs for power, RS232 Rx/Tx,   
					and RS485 Rx/Tx   
					• 
					• 
					Two possible mounting arrangements   
					120 V AC (ANOMA AEC-3590 or other listed   
					direct plug-in Class 2 power supply rated   
					maximum 9 V DC output) or 220 V AC adapter   
					included.   
					805701A1.CDR   
					• 
					• 
					• 
					• 
					Additional power supply terminals supplied to   
					accept isolated 9 V AC / 9 V DC   
					Two interface cables provided   
					(9pin – 9pin, 9pin – 25pin)   
					Suitable for use with direct or modem   
					communications.   
					E83849 UL Listed for the USA and Canada   
					DESCRIPTION   
					The F485 is a self-contained device for converting between RS232, RS485, and fiber optic signals. The   
					converter uses internal switches to select the conversion type (RS232 to RS485, RS232 to FIBER, or   
					RS485 to FIBER) and the RS485 communications baud rates up to 57600 baud. The F485 converter   
					uses the data on the serial port to determine direction and therefore requires no hardware handshaking   
					signals from the computer. The F485 converter can be powered via the power adapter supplied or by   
					connecting an external isolated 9 V AC/DC source to the power supply terminals located at the back of   
					the case. The F485’s versatility and simple design makes it ideal for use with all GE Multilin products in   
					direct and modem communications.   
					TYPICAL CONFIGURATIONS   
					Figure 1: RS232 to RS485 connection   
					Figure 2: RS232 to FIBER and FIBER to RS485   
					g 
					GE Multilin   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F485 COMMUNICATIONS CONVERTER   
					Page 4 of 8   
					CONNECTIONS   
					RS485   
					The RS485 terminals accept a standard shielded twisted   
					RS232   
					The RS232 connector on the F485 converter accepts a   
					standard 9-pin computer cable. See wiring diagram for pin   
					assignments.   
					pair (such as Beldon 9841) and provide connections for a   
					shield. The RS485 terminals have   
					"+", "-" and   
					a 
					a 
					terminating network installed internally and therefore, no   
					external terminating network is required. Observe correct   
					polarity.   
					POWER JACK   
					RS232   
					FIBER OPTIC   
					RS485   
					POWER   
					POWER   
					Connect the supplied power   
					adapter to this input if power is not   
					supplied via the terminals. The   
					power adapter steps down   
					120/220 VAC to 9 VAC.   
					Tx   
					Rx   
					COMPUTER   
					1 
					+ 
					2 
					- 
					3 
					4 
					5 
					+ 
					6 
					- 
					9V   
					AC/DC   
					COM GND   
					FIBER   
					POWER TERMINALS   
					The fiber input/output will accept 50/125, 62.5/125 and   
					100/140um fiber sizes using ST terminated cables. Care   
					should be taken when removing the protective caps to   
					prevent dust from entering the connectors.   
					The power terminals accept either 9 VAC or 9 VDC to power   
					the F485 converter instead of using the power adapter. The   
					GND terminal must be connected to ground to ensure   
					adaquate protection against transients. Pin 4 is the main   
					transient ground for the converter.   
					805700A1.CDR   
					Figure 3: Connections   
					CONFIGURATION   
					The converter box is configured via two internal dip switch banks which are accessible by removing the   
					converter box cover. Switches A1-A8 are used to set the baud rate for RS485 communications and   
					determine whether the converter is DTE (RS232 direct) or DCE (RS232 modem). Switches B1-B6 are   
					used to select the interface type. The designator for each switch is clearly marked on the printed circuit   
					board. The tables shown below provide a description of each switch within the switch banks.   
					Figure 4: Switch Locator   
					SWITCH A (BAUD RATES)   
					BAUD   
					A1   
					A2   
					A3   
					A4   
					A5   
					A6   
					A7   
					SWITCH A (DTE/DCE)   
					1200   
					2400   
					4800   
					9600   
					19200   
					38400   
					57600   
					ON   
					OFF   
					ON   
					OFF   
					OFF   
					ON   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					ON   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					ON   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					ON   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					ON   
					MODE   
					A8   
					OFF   
					ON   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					DTE   
					OFF   
					OFF   
					OFF   
					OFF   
					OFF   
					DCE   
					OFF   
					OFF   
					OFF   
					SWITCH B (CONFIGURATION)   
					CONFIGURATION   
					RS232 TO RS485   
					RS232 TO FIBER   
					RS485 TO FIBER   
					B1   
					B2   
					ON   
					OFF   
					OFF   
					B3   
					B4   
					ON   
					OFF   
					OFF   
					B5   
					OFF   
					ON   
					B6   
					OFF   
					ON   
					OFF   
					OFF   
					ON   
					OFF   
					OFF   
					ON   
					OFF   
					OFF   
					g 
					GE Multilin   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F485 COMMUNICATIONS CONVERTER   
					Page 5 of 8   
					BAUD RATES   
					Two-wire RS485 is half duplex and requires a means for switching between a receive or transmit state.   
					The F485 converter uses the incoming data to control the direction and therefore requires no control   
					signals from the master device (RS232 or fiber) to switch from transmit to receive mode after the last   
					character has been transmitted. The baud rate switches control the length of time that the RS485   
					transmitter will remain in the transmit direction after the last character has been transmitted. The length of   
					time is fixed at 3.5 character times at the selected baud rate making it suitable for use with Modbus® RTU   
					protocol. When converting RS232 to FIBER, these switches (A1-7) have no effect.   
					DTE/DCE CONTROL   
					The DTE/DCE setting reverses the transmit/receive data lines on the RS232 side. For communications   
					between a computer and a slave device, DTE (direct) should be selected. When connecting the F485   
					converter to a modem or other data communications equipment, DCE should be selected. Another   
					application which requires DCE is when two F485 converters are connected back-to-back i.e. converting   
					RS232 to RS485 or fiber and then converting the RS485 or fiber back to RS232. In this case, the second   
					F485 must be set to DCE control.   
					NOTE: Selecting switch settings other than those shown above will cause unpredictable results.   
					FIBER OPTIC TRANSMITTER/RECEIVER (optional)   
					Fiber optic transmissions provide an ideal solution for areas where RS485 communications via a twisted   
					pair have traditionally caused problems. Fiber is immune to electrical interference and provides total   
					isolation.   
					The fiber optic transmitter and receiver used in the F485 converter utilize 820nm wavelength technology   
					and are designed to operate with 50/125µm, 62.5/125µm and 100/140µm fiber sizes using ST terminated   
					cables. The ST connections provide repeatable connections within 0.2 dB typically. The   
					transmitter/receiver pair will typically work with fiber lengths up to 1km.   
					WARNING: Ensure the dust covers are installed when the fiber is not in use. Dirty or   
					scratched connectors can lead to high losses on a fiber link.   
					WARNING: Observing the transmitter output under magnification may cause injury to   
					the eye.   
					INSTALLATION   
					Two different mounting arrangements are possible. The first is by using the two mounting holes inside the   
					plastic case along with the mounting screws supplied. To remove the plastic top, simply press in the two   
					plastic tabs on either end of the box and then pull off the top. The second and less permanent method is   
					to use the Velcro material supplied for attachment to the side of a computer or desk. Where possible,   
					ensure that the LEDs on the front panel are visible. The LEDs are a very valuable tool when   
					troubleshooting a problem.   
					g 
					GE Multilin   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F485 COMMUNICATIONS CONVERTER   
					Page 6 of 8   
					WIRING DIAGRAM   
					ISOLATED   
					TERMINATION   
					AND LINE BIAS   
					RS485   
					CONVERTER   
					BAUD RATE   
					SWITCHES   
					DIRECTION   
					TIMER   
					DATA   
					+ 
					1 
					2 
					3 
					4 
					TO RELAYS   
					- 
					SHIELD   
					GND   
					SR489 STATUS GENERATOR STATUS OUTPUT RELAYS   
					SR489 IN SERVICE   
					SETPOINT ACCESS   
					COMPUTER RS232   
					COMPUTER RS485   
					AUXILIARY RS485   
					BREAKER OPEN   
					R1 TRIP   
					BREAKER CLOSED   
					R2 AUXILIARY   
					R3 AUXILIARY   
					R4 AUXILIARY   
					R5 ALARM   
					HOT STATOR   
					NEG. SEQUENCE   
					GROUND   
					AL   
					T 
					. 
					SETPOINTS   
					LOSS OF FIELD   
					VT FAILURE   
					R6 SERVICE   
					RESET   
					POSSIBLE RESET   
					MESSAGE   
					NEXT   
					BREAKER FAILURE   
					PROGRAM PORT   
					SETPOINT   
					7 
					8 
					5 
					9 
					6 
					MESSAGE   
					ACTUAL   
					ESCAPE   
					ENTER   
					4 
					1 
					. 
					2 
					3 
					VALUE   
					HELP   
					0 
					GE MULTILIN   
					RS485   
					LED Rx   
					TM   
					489 Generator Management Relay   
					e 
					F485 CONVERTER   
					RS485   
					LED Tx   
					ST   
					CONFIGURATION   
					SWITCH   
					CONNECTOR   
					Tx   
					Rx   
					DATA   
					` 
					RS232   
					50/125 um fiber   
					` 
					LED Rx   
					62.5/125 um fiber   
					` 
					VOLTAGE   
					INPUT   
					9VAC/9VDC   
					+ 
					- 
					5 
					6 
					100/140 um fiber   
					RS232   
					LED Tx   
					RS232 INTERFACE   
					F485   
					COMPUTER   
					DTE/DCE   
					RELAY   
					1 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					8 
					DATA   
					RS232   
					DRIVER   
					TXD   
					RXD   
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					3 
					TXD   
					RXD   
					2 
					20   
					7 
					SGND   
					SGND   
					DTE/DCE   
					SWITCH   
					+5V   
					6 
					POWER SUPPLY   
					4 
					~ 
					+ 
					+5V   
					POWER   
					5V   
					9VAC/   
					9VDC   
					5 
					9VDC   
					- 
					20   
					POWER   
					JACK   
					~ 
					9 PIN   
					CONNECTOR   
					25 PIN   
					CONNECTOR   
					COMPUTER   
					120/220 VAC   
					RS232   
					POWER ADAPTER   
					805752A9.CDR   
					ORDER CODE   
					DIMENSIONS   
					g 
					GE Multilin   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				F485 COMMUNICATIONS CONVERTER   
					Page 7 of 8   
					GE Multilin Relay Warranty   
					General Electric Multilin Inc. (GE Multilin) warrants each relay   
					it manufactures to be free from defects in material and   
					workmanship under normal use and service for a period of 24   
					months from date of shipment from factory.   
					In the event of a failure covered by warranty, GE Multilin will   
					undertake to repair or replace the relay providing the   
					warrantor determined that it is defective and it is returned with   
					all transportation charges prepaid to an authorized service   
					center or the factory. Repairs or replacement under warranty   
					will be made without charge.   
					Warranty shall not apply to any relay which has been subject   
					to misuse, negligence, accident, incorrect installation or use   
					not in accordance with instructions nor any unit that has been   
					altered outside a GE Multilin authorized factory outlet.   
					GE Multilin is not liable for special, indirect or consequential   
					damages or for loss of profit or for expenses sustained as a   
					result of a relay malfunction, incorrect application or   
					adjustment.   
					For complete text of Warranty (including limitations and   
					disclaimers) refer to GE Multilin Standard Conditions of Sale.   
					g 
					GE Multilin   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				g 
					GE Multilin   
					215 Anderson Avenue   
					Markham, Ontario   
					Canada L6E 1B3   
					Tel: (905) 294-6222   
					Fax: (905) 201-2098   
					
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |