30" Free-Standing CleanDesign Electric Range
Dimensions and Installation Information (in inches)
KW Rating
30
208V
8.3
2-1/2
25
2-1/2
Acceptable electrical
outlet area
40 Amps†
†Note: Check local codes for required breaker size.
Effective January 1, 1996, the National Electrical Code requires that new construction (not existing)
utilize a 4-conductor connection to an electric range.
29-7/8
Receptacle Locations
Locally approved flexible service cord or conduit must be used because terminals are not
accessible after range installation. See shaded area in drawing for location of electrical outlet
box. Recommended outlet locations allow range to be installed directly against wall.
7-1/2
Note: Conforms to U.L. requirements for 0" spacing for adjacent walls below countertops. To
reduce possibility of scorching walls, it is recommended a minimum of 1-1/2" spacing be allowed
from adjacent side walls to allow for possible extended, high-heat, no-load heating element
operation.
46-7/8
Preferred electrical
outlet area
Roughed-in dimensions
Installation Information: Before installing, consult installation instructions packed with product
for current dimensional data.
25-3/8*
47-5/8
All GE ranges are equipped with
an Anti-Tip device. The installation
Listed by
Underwriters
Laboratories
of this device is an important,
required step in the installation
of the range.