ZBD1800GSS – GE Monogram
Dimensions and Specifications (in inches)
• The dishwasher must be installed so that the drain hose is no more
than 10 feet in length for proper drainage.
This Wall Area Must be
Free of Pipes or Wires
• The dishwasher must be fully enclosed on the top, sides and back,
and must not support any part of the enclosure.
CLEARANCES:
4
24"
min.
When installed into a corner,
Countertop
34" to 35"
Floor to
Underside of
Countertop
allow 2" min. clearance between
dishwasher and adjacent cabinet,
wall or other appliances. Allow
6"
Dishwasher
25-5/8" min. clearance from the
front of the dishwasher for
door opening.
17-5/8" Min.
18" Max.
25-5/8"
Plumbing and Electric Service
Must Enter Inside This Area
34" - 35"*
Clearance for Door
Opening 2" Minimum
17-1/2"
22-1/2"
Before installing, consult installation instructions packed with product,
or available at Monogram.com, for current dimensional data.
ADA-Compliant ZBD1800GSS:
Installation below 34"-high countertops
A reduced-height installation (32-1/2" min.) beneath a 34" countertop
can be accomplished by removing the front leveling legs. The rear
legs should be screwed in flush with the bottom support, as
shipped. The front of the dishwasher must be shimmed to level it.
Water and electrical must be routed through the back wall.
Electrical Requirements
The dishwasher must be supplied with 120V, 60Hz, and connected
to an individual properly grounded branch circuit protected by a
15- or 20-amp circuit breaker or time-delay fuse.
As an ENERGY STAR®
partner, GE has determined
that this product meets the
ENERGY STAR guidelines
for energy efficiency.
Listed by
Underwriters
Laboratories
R
For answers to your Monogram® GE Profileor
GE® appliance questions, visit our website at
GEAppliances.com or call GE Answer Center®
service, 800.626.2000.
Specification Created 3/04
150047
Download from Www.Somanuals.com. All Manuals Search And Download.
|