GE
Security
TM
NetworX Series
NX-7002 GSM/GPRS module
Installation manual
imagination at work
g
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
CONTENTS ............................................................................................................................................................................3
GENERAL INFORMATION.....................................................................................................................................................4
ORDERING INFORMATION ..................................................................................................................................................4
FEATURE DEFINITIONS ........................................................................................................................................................5
PROGRAMMING HE NX-7002 GPRS MODULE ....................................................................................................................7
PROGRAMMING THE NX-7002 VIA THE LED KEYPAD...................................................................................................................7
ENTERING THE PROGRAM MODE..................................................................................................................................................... 7
SELECTING THE MODULE TO PROGRAM.......................................................................................................................................... 7
PROGRAMMING A LOCATION........................................................................................................................................................... 7
EXITING A LOCATION........................................................................................................................................................................ 7
EXITING THE PROGRAM MODE......................................................................................................................................................... 8
PROGRAMMING THE NX-7002 VIA THE LCD KEYPAD ..................................................................................................................8
PROGRAMMING DATA..............................................................................................................................................................8
NUMERICAL DATA ............................................................................................................................................................................ 8
FEATURE SELECTION DATA .............................................................................................................................................................. 9
START UP, ENROLLING AND TESTING THE NX-7002.......................................................................................................10
INSERTING THE SIM CARD .....................................................................................................................................................10
ENROLLING THE SIM CARD ON THE GSM NETWORK ..................................................................................................................11
ENROLLING THE SIM CARD ON THE GPRS NETWORK .................................................................................................................11
TESTING THE RSSI VALUE ......................................................................................................................................................12
TESTING THE GSM AND GPRS CONNECTION............................................................................................................................12
PROGRAMMING THE LOCATIONS.....................................................................................................................................13
NX-7002 FOR PRIMARY OR BACKUP REPORTING............................................................................................................24
NX-7002 FOR PRIMARY REPORTING .......................................................................................................................................24
NX-7002 FOR BACKUP REPORTING ........................................................................................................................................24
NX-7002 PROGRAMMING WORKSHEETS .........................................................................................................................26
INSTALLATION GUIDELINES..............................................................................................................................................32
MOUNTING THE NX-7002..................................................................................................................................................32
NX-7002 LAYOUT AND DESCRIPTION...............................................................................................................................33
TECHNICAL SPECIFICATIONS ............................................................................................................................................34
TECHNICAL SPECIFICATIONS NX-7002....................................................................................................................................34
APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND SIA ................................................................................35
APPENDIX 2: OPERATOR ID CODES ..................................................................................................................................37
NX-7002 Installation manual
Page 3
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL INFORMATION
The NX-7002 is the GPRS module that can be added to the NetworX range of panels (NX-8-
EUR, NX-6-EUR and NX-4-EUR). The NX-7002 GPRS module features include:
•
•
•
•
•
•
Wireless event reporting.
Six programmable report destinations.
Selectable reportable events from eight partitions.
Compatible with PSTN or ISDN reporting.
PSTN/ISDN as backup.
SIA and Contact ID reporting over GPRS, towards Osborne-Hoffman OH2000 TPC/IP
receiver.
•
•
SIA reporting with optional area modifiers using SMS messages.
The control panel can use GSM in addition to PSTN (reporting all panel protocols using
GSM).
•
•
•
Wireless upload/download using a GSM CSD connection.
Upload/download may be initiated remotely or locally.
Optional download sessions during test calls.
The NX-7002 package contains:
•
•
•
•
NX-7002 GSM/GPRS module
1.5m external antenna
2 black PCB guides for mounting
Audio cable
The GSM/GPRS module requires a SIM card (not included). In order to obtain all NX-7002
features, the SIM card needs to support:
•
•
•
Voice channel (event reporting over the voice channel)
Data channel (up/downloading)
GPRS (event reporting towards IP receiver over GPRS)
Contact your local network provider for more information.
ORDERING INFORMATION
For detailed ordering information and part numbers, please refer to the EMEA Distribution
price list of the Caddx product range.
NX-7002 Installation manual
Page 4
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
FEATURE DEFINITIONS
CID
Contact ID reporting protocol.
CSD
Circuit Switched Data. This is the communication used to upload/download data. It is similar
to a modem but it is wireless and built in to the NX-7002 (see locations 0, 162 segment 10 and
location 168).
GPRS
General Packet Radio Service. A global standard for wireless communications with a
maximum speed of 115 kilobits per second. It supports a range of bandwidths and can
transmit and receive both small bursts and large amounts of data.
GSM
Global System for Mobile Communications. A global standard for wireless communications
with a maximum speed of 9.6 kilobits per second. It supports narrowband Time Division
Multiple Access (TDMA).
Non transparent mode
An intermediate modem is used on the network to transfer data from one modem to another
(see location 0 segment 1).
Operator
The network operator for the SIM card.
Polling
Polling is the process by which the system reports periodically to a receiver to say it is still
alive. It works in conjunction with TCP/IP reporting only. Polling is more frequent than a daily
test call but less frequent than continuous monitoring. If you configure a very short polling
time, polling occurs very frequently and can generate large quantities of data. When setting
the polling time, you should consider the speed of the GPRS network and the cost of data
transmission (see location 0, segment 3 and location 162 segment 6).
PUK code
Personal Unblocking Key. The code to use to unblock the SIM card. The SIM card can block
when an incorrect SIM PIN is entered repeatedly.
Report control
A block of reporting data that contains configurations to format selected events into one or
more messages according to pre-configured settings and send them to specified destinations
(see location 1).
RSSI
Received Signal Strength Indicator. This indicates the field signal strength of the NX-7002 (see
location 172 and location 162 segment 11 and 12).
Secondary reporting
The means of reporting events that the control panel fails to report. When secondary
reporting is enabled, the report control set in the NX-7002 will act as a backup for the control
panel (see location 25 and location 162 segment 3).
NX-7002 Installation manual
Page 5
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
SIM card PUK code
See PUK code
SMS
Short Message Service. SMS is a service for sending short text messages to mobile phones (see
locations 1, 145, 163, 164, 167).
Transparent mode
Data is transferred directly from one modem to another modem (see location 0 segment 1).
NX-7002 Installation manual
Page 6
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING HE NX-7002 GPRS MODULE
Programming the NX-7002 via the LED keypad
ENTERING THE PROGRAM MODE
To enter the program mode, press [*]-[8]. At this time, the five function LED’s (Stay, Chime, Exit,
Bypass and Cancel) will begin to flash. Next, enter the “Go To Program Code” (factory default is
[9]-[7]-[1]-[3]). If the “Go To Program Code” is valid, the “Service” LED will flash and the five
function LED’s will illuminate steady. You are now in the program mode and ready to select
the module to program.
Note: It is impossible to enter program mode if any partition or the system is armed.
SELECTING THE MODULE TO PROGRAM
Since all modules connected to the NetworX are programmed through the keypad, the
module you are programming should be the first entry. To program the NX-7002 module,
enter [7]-[8]-[#]. The [7]-[8] is the module number of the NX-7002 and the [#] is the entry key.
PROGRAMMING A LOCATION
Once the number of the module to be programmed has been entered, the “Armed” LED will
illuminate, indicating it is waiting for a programming location to be entered. Any location can
be accessed by directly entering the desired programming location followed by the pound [#]
key. If the location entered is a valid location, the “Armed” LED will extinguish, the “Ready” LED
will illuminate, and the zone LED’s will show the binary data for the first segment of this
location. While entering new data, the “Ready” LED will begin flashing to indicate a data
change in process. The flashing will continue until the new data is stored by pressing the [*]
key. Upon pressing the [*] key, the keypad will advance to the next segment and display its
data. This procedure is repeated until the last segment is reached. Pressing the [#] key will exit
from this location and the “Armed” LED will illuminate again waiting for a new programming
location to be entered. If the desired location is the next sequential location, press the [Police]
key. If the previous location is desired press the [Fire] key. If the same location is desired press
the [Medic] key. To review the data in a location, repeat the above procedure, pressing the [*]
key without any numeric data entry. Each time the [*] key is pressed, the programming data
of the next segment will be displayed for review.
EXITING A LOCATION
After the last segment of a location is programmed, pressing the [*] key will exit that location,
turn the “Ready” LED off and the “Armed” LED on. As before, you are now ready to enter
another programming location. If an attempt is made to program an invalid entry for a
particular segment, the keypad sounder will emit a triple error beep (beep, beep, beep) and
remain in that segment awaiting a valid entry.
NX-7002 Installation manual
Page 7
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
EXITING THE PROGRAM MODE
When all the desired changes in programming have been made, it is time to exit the program
mode. Pressing the [Exit] key will exit this programming level and then return to the “Select a
Module to Program” level. If no additional modules are to be programmed, pressing the [Exit]
key again will exit the program mode. If there is a module to be programmed, it may be
selected by entering its address followed by the [#] key (see Selecting the module to program
for more information). The procedure for programming these devices is the same as for the
control panel, except the locations will be for the module selected.
Note: Each time you exit programming mode, the modem restarts and reads the PIN
number, network operator and SMSC address number from the NX-7002 configuration.
Programming the NX-7002 via the LCD keypad
All steps required for programming are the same as the aforementioned LED keypad. The LCD
keypad display will prompt you for the data required. While in the programming mode, and
not in a location, the number in parenthesis is the location you were previously changing.
For example, if the display reads “Enter location, then # (5)”, it is reminding you that location 5
was the last location you programmed. Refer also to “Programming Data” which follows.
Programming data
Programming data is always one of two types. One type of data is numerical, which can have
values from 0-15 or 0-255 depending on the segment size. The other type of data, feature
selection data, is used to turn features on or off. Use the following procedures with these two
data types.
NUMERICAL DATA
Numerical data is programmed by using the numeric keys of the system keypad to enter a
number from 0-255. To view the data in a location, a binary process is used. With this process,
the LED’s for zones 1 through 8 are utilized, and the numeric equivalents of their illuminated
LED’s are added together to determine the data in a programming location. The numeric
equivalents of these LED’s are as follows:
Zone 1 LED = 1
Zone 5 LED = 16
Zone 2 LED = 2
Zone 6 LED = 32
Zone 3 LED = 4
Zone 7 LED = 64
Zone 4 LED = 8
Zone 8 LED = 128
Example: If the numerical data to be programmed in a location is “66”, press [6] - [6] on the
keypad. The LED’s for zone 2 and zone 7 will become illuminated indicating 66 is in that
location (2 + 64 = 66).
NX-7002 Installation manual
Page 8
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
Once the data is programmed, press the [*] key to enter the data and advance to the next
segment of that location. After the last segment of a location is programmed, pressing the [*]
key will exit that location, turn the “Ready” LED off and the “Armed” LED on. As before, you are
now ready to enter another programming location. If an attempt is made to program a
number too large for a particular segment, the keypad sounder will emit a triple beep,
indicating an error, and remain in that segment awaiting a valid entry.
Remark: The number in the location will be displayed on the LCD keypad. For locations with a
maximum of 15, the hexadecimal equivalent will be displayed in parenthesis.
Example: 11 (B) or 14 (E).
FEATURE SELECTION DATA
Feature selection data will display the current condition (on or off) of eight features associated
with the programming location and segment selected. Pressing a button on the keypad (1
through 8) that corresponds to the “feature number” within a segment will toggle (on/off) that
feature. Pressing any numeric key between [1] and [8] for selection of a feature will make the
corresponding LED illuminate (feature ON). Press the number again, and the LED will
extinguish (feature OFF). You will see that numerous features can be selected from within one
segment. For instance, if all eight features of a segment are desired, pressing [1] - [2] - [3] - [4]
- [5] - [6] - [7] - [8] will turn on LED’s 1 through 8 as you press the keys, indicating that those
features are enabled.
LCD keypad users note: The numbers of the enabled features will be displayed. However, the
features not enabled will display a hyphen (-).
After the desired setting of features is selected for this segment, press the [*] key. This will
enter the data and automatically advance to the next segment of the location. When you are
in the last segment of a location and press the [*] to enter the data, you will exit that location.
This will now turn the “Ready” LED off and the “Armed” LED on. As before, you are now ready
to enter another programming location.
NX-7002 Installation manual
Page 9
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
START UP, ENROLLING AND TESTING THE NX-7002
Inserting the SIM card
Note: You must be free of all static electricity when handling electronic components.
•
•
•
•
•
Always power down the system before inserting a SIM Card.
Locate the SIM card holder n on the board.
Open the SIM card holder by sliding the metal clip as shown in o and lifting the holder.
The SIM card holder opens p.
Slide the SIM card into the holder using the guides. Make sure the contacts (gold pads)
face the circuit board and the angled corners face out q.
•
•
•
Ensure the SIM card is inserted correctly in the holder and close the SIM card holder r.
Slide the metal clip back to the original position as shown in s.
Power up the system. Do not enter programming mode until the SIM card selects the
network operator. The SIM card automatically selects a network operator when enrolled
on the network. To manually select an operator, enter the relevant network operator in
cards contain a pre-programmed SMS service centre address and under normal
circumstances, this should not be changed. If you do need to change it, include the
international country prefix using a '+' instead of leading zeros. Program ‘13’ to insert ‘+’
in the address.
NX-7002 Installation manual
Page 10
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
Enrolling the SIM card on the GSM network
•
•
•
Power up the NX-7002 GPRS module.
information.
•
•
•
Press 78# to select the module.
Press 169# to enter the GSM SIM PIN code location.
Enter the first digit of the SIM PIN code. Press * to move to the next segment. Continue in
this way until all digits are programmed. Press # to save the changes and exit the
location.
•
Exit programming mode. The SIM is automatically enrolled on the GMS network.
Note: Each time you exit programming mode, the modem restarts and reads the PIN
number, network operator and SMSC address number from the NX-7002 configuration.
Enrolling the SIM card on the GPRS network
•
Enter programming mode.
Press 78# to select the module.
•
•
•
Press 169# to enter the GSM SIM PIN code location.
Enter the first digit of the SIM PIN code. Press * to move to the next segment. Continue in
this way until all digits are programmed. Press # to save the changes and exit the
location.
•
•
•
Obtain an Access Point Number from the supplier. Press 60# to enter the Name of GPRS
access point – APN location. Enter the first digit of the APN. Press * to move to the next
segment. Continue in this way until all digits are programmed. Press # to save the
changes and exit the location.
(Optional) You may need to enter the PPP password and PPP User ID required by the
network. To do this, press 32# to select the PPP (dial-up account) user ID location and
program the password. Then press 34# to select the PPP (dial-up account) password
location and program the user ID.
Exit programming mode. The SIM PIN is automatically enrolled on the GSM network.
NX-7002 Installation manual
Page 11
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing the RSSI value
During the enrolling procedure, it is mandatory to check the RSSI value (signal strength) of the
NX-7002 GPRS module and record it in the system documentation. The RSSI value is linked to
the signal level of the GSM network and ranges from 0-31 with 99 as unknown. The RSSI value
may change due to environmental circumstances, for example, additional furniture or metal
constructions. If an RSSI reading is not satisfactory, move the antenna to get a better
reception.
VALUE
DESCRIPTION
The module will not work properly and must be moved to
another location.
Between 1 and 4
The module will work but ideally should be moved to another
location.
These are normal working values for the module located at a
longer distance from the receiver.
Perfect conditions.
Between 5 and 9
Between 10 and 16
Above 17
•
•
•
•
Enter programming mode.
Press 78# to select the NX-7002 GPRS module.
Press 172# to select the Current GPRS RSSI location.
Note the RSSI reading and quit programming.
Testing the GSM and GPRS connection
•
•
•
•
•
•
•
Enter programming mode.
Press 78# to select the NX-7002 GPRS module.
Press 174# to select the Device status flags location.
Check that the SIM card PIN is not blocked: option 1 and option 2 should be ON.
Check that the SIM card is logged onto the GSM network: option 3 should be ON.
Verify if the module is logged into the GPRS network: option 7 should be ON.
Quit programming mode.
7002.
NX-7002 Installation manual
Page 12
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING THE LOCATIONS
LOCATION 0
MODULE MODE OF OPERATION FEATURE SELECTION (8 segments)
This location contains the system characteristics.
Segment 1
1 = Enable site initiated downloading (*98 from a keypad)
Enable remote initiated downloading
2 =
This setting enables the PC to dial into the NX-7002. It is dependent on
other settings (segment 3, 5 and 6).
Remote initiated download must be from known source
If enabled, program the phone number of the PC in location 168.
Enable remote download at test time
3 =
4 =
This setting configures the NX-7002 to automatically dial the PC to
initiate an upload/download session after an autotest. You must
program the autotest in the control panel.
Enable auto-answer incoming CSD GSM download call.
If enabled, the NX-7002 will automatically accept an incoming call.
If disabled, the user needs to accept an incoming call (*99) as soon as a
“ding-dong” is heard on the keypad.
5 =
Callback required for incoming CSD GSM download call
If enabled, the NX-7002 will call back to the PC before starting an
up/download session.
Use V.110 for site-initiated CSD GSM calls
Enable this setting if the PC is on an ISDN line and is using an ISDN
modem.
Use non-transparent mode for site initiated CSD GSM calls
If you are experiencing problems with upload/download, change this
setting from transparent mode to non-transparent mode or vice versa.
6 =
7 =
8 =
Use SIA DCS as backup format (Contact ID if off)
This setting selects the reporting format when using another device as
backup. The same format must be set on the backup device.
Reserved
Segment 2
Segment 3
1 =
2-8
Reserved
1 =
2 =
Polling enable for TCP/IP (for UL AA)
If polling is enabled, set the polling period in location 162, segment 6.
Reserved
3-8
Reserved
Segment 4
1-3
4 =
5-8
TCP/IP reporting in SIA (Contact ID if Off)
Reserved
Reserved
Segment 5-8
NX-7002 Installation manual
Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
LOCATION 1
DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment)
The NX-7002 contains up to six report controls. Each report control can be defined for SMS
reporting, TCP/IP reporting or email reporting (not yet available). This location contains the
report destination for report control 1. Select from the table below.
DATA
FORMAT
DESCRIPTION
Report control 1 is disabled
0
1
2
3
Disabled
TCP/IP 1
TCP/IP 2
Email 1
Reporting to TCP/IP receiver 1
Reporting to TCP/IP receiver 2
Email Reporting to Email Account 1 (not yet
available)
4
Email 2
Email Reporting to Email Account 2 (not yet
available)
5
6
SMS 1
SMS 2
SMS Reporting to Mobile Phone 1
SMS Reporting to Mobile Phone 2
LOCATION 2
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 1 (1 segment)
If the primary destination selection (location 1) fails, a backup destination can be selected. If
using another device as the backup destination, for example, panel dialler, set the reporting
format (SIA or CID) in location 0, segment 2, option 1 and enable test report events for the
backup device. This location contains the backup report destination for report control 1. Select
from the table below.
DATA
FORMAT
DESCRIPTION
Backup Report control 1 is disabled
Backup Reporting to TCP/IP receiver 1
Backup Reporting to TCP/IP receiver 2
0
1
2
3
Disabled
TCP/IP 1
TCP/IP 2
Email 1
Backup Email Reporting to Email Account 1 (not yet
available)
4
Email 2
Backup Email Reporting to Email Account 2 (not yet
available)
5
6
SMS 1
SMS 2
Backup SMS Reporting to Mobile Phone 1
Backup SMS Reporting to Mobile Phone 2
255
Other dialler
The NX-7002 is not used as backup. Instead another
dialler is used (for example: panel dialler)
LOCATION 3
REPORT DELAY FOR REPORT CONTROL 1 (1 segment)
The delay in seconds before the NX-7002 GPRS module reports. If any other events occur
during this delay, they are sent with the first event in one message if using SMS reporting. This
does not apply if using TCP/IP reporting (it does not support multiple events in one message).
This can be from 0 to 255 seconds.
NX-7002 Installation manual
Page 14
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 4
EVENT SELECTION FOR REPORT CONTROL 1 BY PARTITION (16 segments, feature selection
data)
All events for report control 1 are enabled by default. Select the partition(s) to include in the
event report. Enabled events are formatted into one or more messages according to pre-
configured settings and sent to the selected report destination. Enable the Test Reports event
group if using the NX-7002 as backup to another auxiliary dialler.
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
Alarms (and Restores)
Open / Close
Bypass
Zone trouble
Power trouble (AC failure and Low Battery)
Siren & Line Fault
Test Report
Program, Download & Log full
Tamper
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble
Fail To Communicate
Zone Activity Monitoring
Reserved
LOCATION 5
LOCATION 6
LOCATION 7
DESTINATION SELECTION FOR REPORT CONTROL 2 (1 segment)
This location contains the report destination for report control 2. See location 1.
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 2 (1 segment)
This location contains the backup report destination for report control 2. See location 2.
REPORT DELAY FOR REPORT CONTROL 2 (1 segment)
The delay in seconds before the NX-7002 GPRS module reports to report control 2. See
location 3.
LOCATION 8
EVENT SELECTION FOR REPORT CONTROL 2 BY PARTITION (16 segments, feature selection
data)
All events for report control 2 are disabled by default. See location 4.
DESTINATION SELECTION FOR REPORT CONTROL 3 (1 segment)
This location contains the report destination for report control 3. See location 1.
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 3 (1 segment)
This location contains the backup report destination for report control 3. See location 2.
REPORT DELAY FOR REPORT CONTROL 3 (1 segment)
LOCATION 9
LOCATION 10
LOCATION 11
The delay in seconds before the NX-7002 GPRS module reports to report control 3. See
location 3.
NX-7002 Installation manual
Page 15
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 12
EVENT SELECTION FOR REPORT CONTROL 3 BY PARTITION (16 segments, feature selection
data)
All events for report control 3 are disabled by default. See location 4.
DESTINATION SELECTION FOR REPORT CONTROL 4 (1 segment)
This location contains the report destination for report control 4. See location 1.
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 4 (1 segment)
This location contains the backup report destination for report control 4. See location 2.
REPORT DELAY FOR REPORT CONTROL 4 (1 segment)
LOCATION 13
LOCATION 14
LOCATION 15
The delay in seconds before the NX-7002 GPRS module reports to report control 4. See
location 3.
LOCATION 16
EVENT SELECTION FOR REPORT CONTROL 4 BY PARTITION (16 segments, feature selection
data)
All events for report control 4 are disabled by default. See location 4.
DESTINATION SELECTION FOR REPORT CONTROL 5 (1 segment)
This location contains the report destination for report control 5. See location 1.
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 5 (1 segment)
This location contains the backup report destination for report control 5. See location 2.
REPORT DELAY FOR REPORT CONTROL 5 (1 segment)
LOCATION 17
LOCATION 18
LOCATION 19
The delay in seconds before the NX-7002 GPRS module reports to report control 5. See
location 3.
LOCATION 20
EVENT SELECTION FOR REPORT CONTROL 5 BY PARTITION (16 segments, feature selection
data)
All events for report control 5 are disabled by default. See location 4.
DESTINATION SELECTION FOR REPORT CONTROL 6 (1 segment)
This location contains the report destination for report control 6. See location 1.
BACKUP DESTINATION SELECTION FOR REPORT CONTROL 6 (1 segment)
This location contains the backup report destination for report control 6. See location 2.
REPORT DELAY FOR REPORT CONTROL 6 (1 segment)
LOCATION 21
LOCATION 22
LOCATION 23
The delay in seconds before the NX-7002 GPRS module reports to report control 6. See
location 3.
NX-7002 Installation manual
Page 16
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 24
LOCATION 25
EVENT SELECTION FOR REPORT CONTROL 6 BY PARTITION (16 segments, feature selection
data)
All events for report control 6 are disabled by default. See location 4.
PRIMARY REPORTING FLAG FOR REPORT CONTROLS (1 segment)
The NX-7002 contains up to six report controls. Turn on the relevant option to enable primary
reporting for that report control. Turn off the option to enable secondary reporting for that
report control. When secondary reporting is enabled, the report control acts as a backup for
the control panel.
Segment 1
1 = On: Report Control 1 acts as Primary Reporting;
Off: Report Control 1 acts as Secondary Reporting
2 = On: Report Control 2 acts as Primary Reporting;
Off: Report Control 2 acts as Secondary Reporting
3 = On: Report Control 3 acts as Primary Reporting;
Off: Report Control 3 acts as Secondary Reporting
4 = On: Report Control 4 acts as Primary Reporting;
Off: Report Control 4 acts as Secondary Reporting
5 = On: Report Control 5 acts as Primary Reporting;
Off: Report Control 5 acts as Secondary Reporting
6 = On: Report Control 6 acts as Primary Reporting;
Off: Report Control 6 acts as Secondary Reporting
7-8 Reserved
LOCATION 26 –
LOCATION 31
RESERVED
LOCATION 32
PPP (dial-up account) USER ID, characters 1 - 16 (16 segments)
Optional if using TCP/IP reporting. Contact the network provider to confirm if a PAP login is
required and to obtain the user ID and password.
LOCATION 33
LOCATION 34
PPP (dial-up account) USER ID, characters 17 - 32 (16 segments)
See location 32.
PPP (dial-up account) PASSWORD, 16 characters (16 segments)
See location 32.
LOCATION 35 –
LOCATION 59
RESERVED
LOCATION 60
NAME OF GPRS ACCESS POINT - APN, characters 1 - 16 (16 segments)
This is a mandatory setting if using TCP/IP reporting. Contact the network provider to obtain
the GPRS access point name.
LOCATION 61
NAME OF GPRS ACCESS POINT - APN, characters 17 - 32 (16 segments)
See location 60.
NX-7002 Installation manual
Page 17
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 62
LOCATION 63
NAME OF GPRS ACCESS POINT - APN, characters 33 - 48 (16 segments)
See location 60.
NAME OF GPRS ACCESS POINT - APN, characters 49 – 64 (16 segments)
See location 60.
LOCATION 64 -
LOCATION 100
RESERVED
LOCATION 101
DHCP ASSIGNED IP ADDRESS (4 segments)
When the NX-7002 logs into the GPRS network, it is automatically assigned to an IP address.
This location is a read-only location.
LOCATION 102
LOCATION 103
IP ADDRESS FOR TCP/IP RECEIVER 1 (4 segments)
If using TCP/IP reporting, enter in this location the IP address of the receiver 1.
IP ADDRESS FOR TCP/IP RECEIVER 2 (4 segments)
If using TCP/IP reporting, enter in this location the IP address of the receiver 2.
LOCATION 104 –
LOCATION 118
RESERVED
LOCATION 119
RECEIVER ALARM AND POLL PORT (4 segments)
The number of the TCP/IP port to which polling and alarms are reported. The default port is
9999 and under normal circumstances should not be changed.
LOCATION 120 –
LOCATION 138
RESERVED
LOCATION 139
TCP/IP 1 ACCOUNT NUMBER (8 segments)
The SIA or Contact ID account number used for reporting towards the TCP/IP receiver. SIA
account numbers are 6 digits long. Contact ID account numbers are 4 digits long. Add leading
zeros to create an 8-digit number.
LOCATION 140
LOCATION 141
TCP/IP 1 RECEIVER NUMBER (4 segments)
The phone line receiver number associated with the TCP/IP 1 account.
TCP/IP 1 LINE NUMBER (4 segments)
The line number associated with the TCP/IP 1 account. Enter the account number and
destination number for the receiver.
LOCATION 142
LOCATION 143
TCP/IP 2 ACCOUNT NUMBER (8 segments)
See location 139.
TCP/IP 2 RECEIVER NUMBER (4 segments)
See location 140.
NX-7002 Installation manual
Page 18
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 144
LOCATION 145
TCP/IP 2 LINE NUMBER (4 segments)
See location 141.
SMS 1 ACCOUNT NUMBER (8 segments)
The SIA account number used for SMS reporting. SIA account numbers are 6 digits long. Enter
the first digit of the SIM PIN code in segment 3 (segment 1 and 2 are not used). Press * to move
to the next segment. Continue in this way until all digits are programmed.
LOCATION 146
SMS 2 ACCOUNT NUMBER (8 segments)
See location 145.
LOCATION 147 –
LOCATION 153
RESERVED
LOCATION 154
ACCOUNT NUMBER FOR PARTITION 1 (8 segments)
The account code sent when partition 1 is reported. Use when a different account code for
each partition is required. When there is also an account code set for each report destination
(see location 139/142/145/146), the partition account code takes precedence.
LOCATION 155
LOCATION 156
LOCATION 157
LOCATION 158
LOCATION 159
LOCATION 160
LOCATION 161
ACCOUNT NUMBER FOR PARTITION 2 (8 segments)
See location 154.
ACCOUNT NUMBER FOR PARTITION 3 (8 segments)
See location 154.
ACCOUNT NUMBER FOR PARTITION 4 (8 segments)
See location 154.
ACCOUNT NUMBER FOR PARTITION 5 (8 segments)
See location 154.
ACCOUNT NUMBER FOR PARTITION 6 (8 segments)
See location 154.
ACCOUNT NUMBER FOR PARTITION 7 (8 segments)
See location 154.
ACCOUNT NUMBER FOR PARTITION 8 (8 segments)
See location 154.
NX-7002 Installation manual
Page 19
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 162
TIMERS AND COUNTERS (16 segments, numerical data)
Location 162 contains the duration of various system timing functions.
Segment 1
Segment 2
Segment 3
Max Number of network attempts
The number of report attempts the NX-7002 GPRS module makes to send
a report. This can be from 0 to 15.
Report attempts for FTC
The number of attempts that can be made to a specific report destination
before the Fail to Communicate condition is set. This can be from 1 to 15.
Maximum reports in 24 hours
The NX-7002 GPRS module stops reporting messages when the number
of messages in a 24-hour time frame exceeds this number. This can be
from 1 to 255. If set to 0, there is no limitation.
Time in seconds for overall network attempt
The maximum length of time for each attempt by the NX-7002 to report
to each receiver. If the report is not successful during this time, the
attempt is abandoned. This can be from 0 to 255 seconds.
Reserved
Segment 4
Segment 5
Segment 6
TCP/IP Polling time in minutes
This setting must match the TCP/IP polling time set on a TCP/IP receiver.
The setting on the TCP/IP receiver is determined by the speed of the GPRS
network and cost of data transmission. This can be from 1 to 255. If set to
0, the setting is disabled.
Reserved
Reserved
Segment 7
Segment 8
Segment 9
Reserved
Segment 10 Baud rate for CSD/GSM download
This setting must match the baud rate set on the PC modem. 4=2400
Baud, 5=4800 Baud, 6=9600 Baud.
Segment 11 GSM line fault RSSI threshold
The acceptable level of the RSSI signal. If the signal falls below this level
for the amount of time set in segment 12, a line fault is generated. This
can be from 1 to 31. If set to 0, the setting is disabled.
Segment 12 GSM line fault time
The length of time the RSSI signal must be below the RSSI threshold
before a line fault is generated. This can be from 0 to 255 seconds.
Segment 13 Control reporting timeout for secondary reporting
The maximum time during which the control panel must report an event.
If the NX-7002 report control (SMS or TCP/IP report control) is set for
secondary reporting and the control panel does not report the event
during this time, the report control reports the event. This can be from 1
to 255 seconds. If set to 0, the setting is disabled.
Segment 14 Reserved
LOCATION 163
SMS 1 PHONE NUMBER (20 segments)
The phone number to which SMS reports are sent. This phone number is independent from the
phone numbers programmed in the control panel. “14” indicates the end of the phone
number. Program “11” to insert “*” in the phone number, program “12” to insert “#” and
program “13” to insert “+”. It is recommended to add the country prefix before the number. For
example, +32 followed by the phone number.
NX-7002 Installation manual
Page 20
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 164
SMS 1 FORMAT (1 segment)
The communicator format used to transmit to the SMS 1 report destination from the NX-7002
GPRS module. Consult the instructions for your central station receiver to determine which
format is compatible. SIA reporting over SMS can be set to one of three modes:
DATA
FORMAT
0
1
2
SIA Separate Events
SIA Combined Events
SIA with Area Modifier
If “0” (Separate Events) is selected, messages are sent using the syntax:
>aaaaaa eennn [eennn …].
For example, >123456 BA001
If “1” (Combined Events) is selected, messages are sent using the syntax:
>aaaaaa eennn [eennn …] [/aaaaaa eennn [eennn …]…] .
For example, >123456 BA001/987654 YT000/345678 TA030
If “2” (Area Modifier) is selected, messages are sent using the syntax:
>aaaaaa eennn[/Rin] [eennn[/Rin] …].
For example, > 987654 BA001/Ri1 BA003/Ri1 YT000 TA030/Ri3.
Syntax Description :
>
The message opening character.
A six-digit account code.
aaaaaa
ee
nnn
Rin
.
A two-digit SIA code.
A three-digit number, e.g. zone number.
Area modifier, 'Ri' is literal, n is the area or partition number.
The message closing character.
Separator
/
[X]
[X …]
X is optional
X is optional and may be repeated one or more times.
NX-7002 Installation manual
Page 21
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 165
LOCATION 166
SMS 2 PHONE NUMBER (20 segments)
See location 163.
SMS 2 FORMAT (1 segment)
See location 164.
Note: By default, not more than 20 SMS messages will be transmitted in a 24 hour time
period. If needed, this number can be changed (see location 162 segment 3).
LOCATION 167
LOCATION 168
SMS SERVICE CENTRE NUMBER (20 segments)
This number is mandatory when SMS reporting is used. Usually the SIM card automatically
dials this number. “14” indicates the end of the phone number. Program “11” to insert “*” in the
phone number, program “12” to insert “#” and program “13” to insert “+”. It is recommended to
add the country prefix before the number. For example, +32 followed by the number.
UPLOAD/DOWNLOAD PHONE NUMBER (FOR CSD GSM) (20 segments)
This number is mandatory if up/downloading via the NX-7002 is required using the call-back
feature. An Up/download call will use the data channel. Contact your network provider to
make sure your SIM card supports the data channel.
Program the call-back number in this location. “14” indicates the end of the phone number.
Program “11” to insert “*” in the phone number, program “12” to insert “#” and program “13”
to insert “+”.
LOCATION 169
LOCATION 170
GSM SIM PIN CODE (8 segments)
Enter the SIM pin code in this location. A “10” indicates the end of the code.
GSM OPERATOR SELECTION (6 segments)
The network operator ID code. Set this to 00000 to allow the SIM card automatically select a
network operator. Alternatively, enter an operator ID code in this location to manually select a
network operator. If using a 5-digit code, enter ‘A’ or ‘10’ after the code. Appendix 2 lists all
network operators and ID codes. An invalid selection or unreachable network will prevent
location 174, segment 3 turning on.
LOCATION 171
LOCATION 172
LOCATION 173
CURRENT GSM OPERATOR (READ ONLY) (1 segment)
This location will show the name of the automatically or manually selected GSM network
operator. This location is read only and only valid when the NX-7002 is logged into the GSM
CURRENT GSM RSSI (READ ONLY) (1 segment)
This location will show the RSSI (Received Signal Strength Indicator) value. The RSSI value is
periodically updated when logged into the network. RSSI values range from 0 to 31 with 99 as
unknown. See Testing the RSSI value for more information.
CURRENT GPRS BIT ERROR RATE % (READ ONLY) (1 segment)
This location will show the BER (Bit Error Rate) value in %. The BER value is periodically
updated when logged into the network. BER values range from 0 to 7 with 99 as unknown.
NX-7002 Installation manual
Page 22
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
LOCATION 174
DEVICE STATUS FLAGS (2 segments)
This location contains specific status information of the GSM/GPRS module. If the option is
”On”, the status condition is true.
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =
On: Communication with GSM modem OK
On: SIM card PIN is OK
On: Logged in to the GSM network
On: Sending SMS
On: Using GSM audio connection
On: Using GSM CSD connection
On: Connected to GPRS network
On: SIM card PUK code required
Segment 1
1 =
On: Battery voltage failure
The NX-7002 measures and monitors battery voltage. It shares a
battery with the control panel.
Segment 2
2 =
3 =
On: GSM PSU voltage failure
The main battery creates a 3.8 V power supply for the GPRS modem.
On: Bus voltage failure
The bus supplies a 13.8 V voltage to the NX-7002.
On : Communication channel failure
On : Up/download session in progress
On : Up/download session starting
On : Reporting in Progress
4 =
5 =
6 =
7 =
8 =
On : RSSI level at acceptable level
LOCATION 175
LOCATION 176
LOCATION 177
LOCATION 178
GSM MODEM MANUFACTURER (READ ONLY) (16 segments)
This location displays the manufacturer of the GSM/GPRS modem used on the NX-7002.
GSM MODEM MODEL (READ ONLY) (16 segments)
This location displays the model of GSM/GPRS modem used on the NX-7002.
GSM MODEM SOFTWARE REVISION (READ ONLY) (16 segments)
This location displays the software revision of the GSM/GPRS modem used on the NX-7002.
GSM MODEM SERIAL NUMBER (READ ONLY) (16 segments)
This location displays the serial number of the GSM/GPRS modem used on the NX-7002.
LOCATION 179 –
LOCATION 215
RESERVED
NX-7002 Installation manual
Page 23
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
NX-7002 FOR PRIMARY OR BACKUP REPORTING
NX-7002 for primary reporting
The NX-7002 can be configured to be the primary transmitter. In this case, the NX-7002 acts
as the main alarm reporting device.
If the NX-7002 fails, for example, if there is no GSM coverage or there is jamming, if the
network of the provider is down or there are technical problems on the receiver side, another
device (the onboard dialler of the panel or an auxiliary dialler) can be configured to act as
backup. In this case, set location 2 to 255 (Other dialler) as backup for the NX-7002.
If another dialler is used as the backup device:
•
•
Enable the Autotest report options in that dialler.
Ensure that the reporting format used in the backup device is the same as the reporting
format used in the NX-7002.
If the NX-7002 fails to report over the GPRS network to the IP receiver, you can use a second
report control from the NX-7002 as backup. For example, use SMS reporting as the backup
report control. In this case, set location 1 to 1 (TCP/IP1) and location 2 to 5 (SMS1).
NX-7002 for backup reporting
The NX-7002 can be configured to transmit events only when the primary dialler (control
panel, auxiliary dialler) fails to do so. In this case, the NX-7002 acts as the backup reporting
device.
The NX-7002 can be configured as the backup device of the control panel in two ways:
1. Backup reporting using a report control (TCP/IP or SMS)
Select the desired report control in location 1 and set the corresponding report control as a
secondary (backup) report control in location 25.
2. Backup reporting using the GSM voice channel
In this case, the NX-7002 acts as a transparent backup device for the control panel. No
programming in the NX-7002 is required, except for the SIM PIN code in location 169. All event
reporting is programmed in the control panel.
The phone number must be programmed twice in the control panel:
•
•
Program phone number 1 as usual. For example, 011234567.
Enter a “10” in front of phone number 2. For example, 10011234567. This forces the NX-
7002 to dial the phone number instead of the control panel.
•
The special audio cable (included) must be stuffed between the NX-7002 and the control
NX-7002 Installation manual
Page 24
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
The NX-7002 can be configured as the backup device of an auxiliary dialler (NX-590 TCP/IP
module or NX-570 ISDN module):
•
•
•
Select the desired report control in location 1.
Enable the Autotest report options.
Ensure that the reporting format used with the auxiliary dialler is the same as the
reporting format used in the NX-7002.
NX-7002 Installation manual
Page 25
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
NX-7002 PROGRAMMING WORKSHEETS
(Factory defaults are in bold italic text)
LOC
PG
DESCRIPTION
DEFAULT
PROGRAMMING DATA
0
13
MODE OF OPERATION FEATURE SELECTION
Segment 1 (Circle Numbers To Program)
Segment 2 (Circle Numbers To Program)
1
Enable site initiated downloading (*98 from a
keypad)
1
Use SIA DCS as backup format (Contact ID if off)
2
Enable remote initiated downloading
2
3
Reserved
Reserved
3
Remote initiated download must be from
known source
4
5
Enable remote download at test time
4
5
Reserved
Reserved
Enable auto-answer incoming CSD GSM
download call
6
Callback required for incoming CSD GSM
download call
6
Reserved
7
8
Use V.110 for site-initiated CSD GSM calls
7
8
Reserved
Reserved
Use non-transparent mode for site initiated
CSD GSM calls
13
Segment 3 (Circle Numbers To Program)
Segment 4 (Circle Numbers To Program)
1
2
3
4
5
6
7
8
Reserved
1
2
3
4
5
6
7
8
Reserved
Polling enable (for UL AA)
Reserved
Reserved
Reserved
Reserved
TCP/IP Reporting in SIA (Contact ID if off)
Reserved
Reserved
Reserved
Reserved
Reserved
0
Reserved
Reserved
Reserved
1
2
14
14
DESTINATION SELECTION FOR REPORT CONTROL 1
BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 1
0
3
4
14
15
REPORT DELAY FOR REPORT CONTROL 1
0
EVENT SELECTION FOR REPORT CONTROL 1 (BY PARTITION)
Alarms and Restores
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
1-2-3-4-5-6-7-8
0
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure / Low Batt.)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
Tampers (zones and box)
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble (incl. keypad)
Failure To Communicate
Zone Activity Monitoring
Reserved
5
6
15
15
DESTINATION SELECTION FOR REPORT CONTROL 2
BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 2
0
7
15
REPORT DELAY FOR REPORT CONTROL 2
0
NX-7002 Installation manual
Page 26
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
LOC
PG
DESCRIPTION
Segment 1
DEFAULT
PROGRAMMING DATA
8
15
EVENT SELECTION FOR REPORT CONTROL 2 (BY PARTITION)
Alarms and Restores
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure / Low Batt.)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
Tampers (zones and box)
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble (incl. keypad)
Failure To Communicate
Zone Activity Monitoring
Reserved
9
16
16
DESTINATION SELECTION FOR REPORT CONTROL 3
10
BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 3
0
11
12
16
16
REPORT DELAY FOR REPORT CONTROL 3
0
EVENT SELECTION FOR REPORT CONTROL 3 (BY PARTITION)
Alarms and Restores
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure / Low Batt.)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
Tampers (zones and box)
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble (incl. keypad)
Failure To Communicate
Zone Activity Monitoring
Reserved
13
14
16
16
DESTINATION SELECTION FOR REPORT CONTROL 4
BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 4
0
15
16
REPORT DELAY FOR REPORT CONTROL 4
0
NX-7002 Installation manual
Page 27
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
LOC
PG
DESCRIPTION
Segment 1
DEFAULT
PROGRAMMING DATA
16
16
EVENT SELECTION FOR REPORT CONTROL 4 (BY PARTITION)
Alarms and Restores
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure / Low Batt.)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
Tampers (zones and box)
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble (incl. keypad)
Failure To Communicate
Zone Activity Monitoring
Reserved
17
18
16
16
DESTINATION SELECTION FOR REPORT CONTROL 5
BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 5
0
19
20
16
17
REPORT DELAY FOR REPORT CONTROL 5
0
EVENT SELECTION FOR REPORT CONTROL 5 (BY PARTITION)
Alarms and Restores
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure / Low Batt.)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
Tampers (zones and box)
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble (incl. keypad)
Failure To Communicate
Zone Activity Monitoring
Reserved
21
22
17
17
DESTINATION SELECTION FOR REPORT CONTROL 6
BACKUP DESTINATION SELECTION FOR REPORT
CONTROL 6
0
23
17
REPORT DELAY FOR REPORT CONTROL 6
0
NX-7002 Installation manual
Page 28
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
LOC
PG
DESCRIPTION
Segment 1
DEFAULT
PROGRAMMING DATA
24
17
EVENT SELECTION FOR REPORT CONTROL 6 (BY PARTITION)
Alarms and Restores
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
Open/Close
Bypass
Zone Trouble
Power Trouble (AC Failure / Low Batt.)
Siren & Telephone Fault
Test Reports
Program, Download, & Log Full
Tampers (zones and box)
Short Circuit
Sensor Lost
Sensor Low Battery
Expander Trouble (incl. keypad)
Failure To Communicate
Zone Activity Monitoring
Reserved
25
17
PRIMARY REPORTING FLAGS FOR REPORT CONTROL 1 TO 6
Segment 1 (Circle Numbers To Program)
1
2
3
4
5
6
7
8
On = Report Control 1 is Primary Reporting Flag / Off = Report Control 1 is Backup for control panel
On = Report Control 2 is Primary Reporting Flag / Off = Report Control 2 is Backup for control panel
On = Report Control 3 is Primary Reporting Flag / Off = Report Control 3 is Backup for control panel
On = Report Control 4 is Primary Reporting Flag / Off = Report Control 4 is Backup for control panel
On = Report Control 5 is Primary Reporting Flag / Off = Report Control 5 is Backup for control panel
On = Report Control 6 is Primary Reporting Flag / Off = Report Control 6 is Backup for control panel
Reserved
Reserved
26 - 31
32
17
18
18
18
18
18
18
18
18
18
19
19
19
19
19
19
19
19
19
19
19
19
20
20
20
RESERVED
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
PPP (dial-up account) user ID (chars 1 - 16)
PPP (dial-up account) user ID (chars 17 - 32)
PPP (dial-up account) password
RESERVED
33
34
35 – 59
60
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Name of GPRS access point - APN (chars 1 - 16)
Name of GPRS access point - APN (chars 17 - 32)
Name of GPRS access point - APN (chars 33 - 48)
Name of GPRS access point - APN (chars 49 - 64)
RESERVED
61
62
63
64 - 100
101
NX-7002 assigned IP address (DHCP)
IP address for TCP/IP receiver 1
IP address for TCP/IP receiver 2
RESERVED
0.0.0.0
0.0.0.0
0.0.0.0
102
103
104-118
119
Receiver alarm and poll port
RESERVED
9.9.9.9
120-138
139
TCP/IP 1 Account number
TCP/IP 1 Receiver number
TCP/IP 1 Line number
0-0-0-0-1-0-0-0
0-0-0-1
140
141
0-0-0-1
142
TCP/IP 2 Account number
TCP/IP 2 Receiver number
TCP/IP 2 Line number
0-0-0-0-1-0-0-0
0-0-0-1
143
144
0-0-0-1
145
SMS 1 Account number
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
146
SMS 2 Account number
147-153
RESERVED
NX-7002 Installation manual
Page 29
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
LOC
154
155
156
157
158
159
160
161
162
PG
20
20
20
20
20
20
20
20
21
DESCRIPTION
Account number partition 1
Account number partition 2
Account number partition 3
Account number partition 4
Account number partition 5
Account number partition 6
Account number partition 7
Account number partition 8
TIMERS AND COUNTERS
DEFAULT
0-0-0-0-0-0-0-0
PROGRAMMING DATA
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
0-0-0-0-0-0-0-0
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Segment 7
Segment 8
Segment 9
Segment 10
Segment 11
Segment 12
Segment 13
Segment 14
Segment 15
Segment 16
Max Number of network attempts
8
4
Report attempts for Fail To Communicate
Maximum reports in 24 hours
Time in seconds for overall network attempt
Reserved
20
80
TCP/IP Polling time in minutes for PPP connections
20
Reserved
Reserved
Reserved
Baud rate for CSD/GSM download
6
5
GSM line fault RSSI threshold
GSM line fault time in seconds
20
180
Control reporting timeout in seconds for secondary reporting
Reserved
Reserved
Reserved
22
SMS 1 Phone number
14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-
14-14
164
165
22
22
SMS 1 Format
0
SMS 2 Phone number
14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-
14-14
166
167
22
23
SMS 2 Format
0
SMS service centre address (phone number)
14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-
14-14
168
23
U/D call-back phone number (for CSD GSM)
14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-
14-14
169
170
171
23
23
23
23
23
GSM SIM PIN code
10-10-10-10-10-10-10-10
GSM operator selection
0-0-0-0-0-A
Current GSM operator (read only)
Current GSM RSSI (read only)
Current GPRS Bit Error Rate % (read only)
(name of operator)
99
99
173
NX-7002 Installation manual
Page 30
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
LOC
PG
DESCRIPTION
DEVICE STATUS FLAGS (read only)
Segment 1
DEFAULT
PROGRAMMING DATA
174
24
1
2
3
4
5
6
7
8
On = Communication with GSM modem OK
On = SIM card PIN is OK
On = Logged in to the GSM network
On = Sending SMS
On = Using GSM audio connection
On = Using GSM CSD connection
On = Connected to GPRS network
On = SIM card PUK code required
Segment 2
1
2
3
4
5
6
7
8
On = Battery voltage failure
On = GSM PSU voltage failure
On = Bus voltage failure
On = Communication channel failure
On = U/D session in progress
On = U/D session starting
On = Reporting in progress
On = Good RSSI Level
Segment 3
1
2-8
On = Max reports in 24h limit reached
Reserved
175
176
24
24
24
24
24
GSM modem manufacturer (read only)
GSM modem model (read only)
GSM modem software revision (read only)
GSM modem serial number (read only)
RESERVED
(name of manufacturer)
(name of model)
177
(software revision)
(serial number)
178
179-215
NX-7002 Installation manual
Page 31
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
INSTALLATION GUIDELINES
•
Avoid installing the module:
-
-
-
Where temperatures exceed 49°C or fall below 0°C.
In the immediate vicinity of electronic equipment.
In humid rooms. The module is not hermetically sealed and excess moisture on the
circuit board can eventually cause an electrical fault.
•
•
Keep the antenna within 2 m of the panel.
Before permanently mounting the module, test it at the intended location to ensure that
the remote alarm receiver can receive signal transmissions. There may be blind or non-
operational locations within the installation. Normally these can be overcome by moving
the antenna.
Note: To test the signal strength at the intended location, insert the SIM card into a mobile
phone and check the strength indicator on the mobile phone.
MOUNTING THE NX-7002
Inside the can, several 2-holed insertion points have been constructed. This allows for either
vertical or horizontal placement of the modules. Notice that each insertion point has two sizes
of holes -a larger hole and a smaller hole.
Diagram 1: The black plastic PCB guides are grooved on one
edge where the PC board will be seated. The end with the half-
moon protrusion fits into the larger hole. The smaller hole is for
the screw.
Diagram 2: Place the first black plastic PCB guide in the top
insertion point, grooved edge downward. The half-moon
protrusion will be in the large hole. It does not require force.
Insert one of the provided screw into the smaller hole (from
inside the can) to secure it in place. A screwdriver should reach
through the notch that runs the length of the guide to tighten
the screw. The second PBC guide should be positioned opposite
the first (grooved edge up) and placed in the lower insertion
point, using the same procedures described above. Once
mounted, screw it in securely.
Diagram 3: The module should slide freely in the grooves of
both guides.
NX-7002 Installation manual
Page 32
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
NX-7002 LAYOUT AND DESCRIPTION
9
8
1
2
3
4
1
1
11
10
7
5
7
6
DESCRIPTION
1
2
3
4
5
6
7
8
Future use (VVMIQ)
SIM card holder
GPRS modem
Connect antenna to this connector
Header for software upgrade
Connect to battery
Connect main panel battery leads to these connectors
Audio tap connector (CON5)
If the NX-7002 uses the voice channel for event reporting, the special audio cable
(included) needs to be stuffed between this connector of the NX-7002 and the Audio
Tap connector of the control panel.
9
Keypad bus terminals
10
Status LED’s
GSM in use: ON when events are send over the voice or data channel (Up/download)
PSU error: ON when the modem power source is to low
Reporting: ON when data is reported to the IP receiver or Mobile phone (SMS)
GPRS active: ON when the module is connected to the GPRS network and the first event is
send. It turns OFF when the module uses the voice channel
SIM error: ON when an incorrect PIN code is entered
GSM com: reserved
Network OK: reserved
Bus com: flashes when communicating on the NetworX bus
Green LED: ON when connected to TCP/IP receiver
11
NX-7002 Installation manual
Page 33
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
TECHNICAL SPECIFICATIONS
Technical specifications NX-7002
Power supply voltage
Current consumption
- Nominal
12Vdc
30mA at 13.8Vdc
up to 2 Amps peak
max. 12V/7.2Ah
0 - 49° C
Max 93% non condensating
102 x 97 x 24 mm
115 g
- Maximum
Battery
Operating temperature
Humidity
Dimensions (PCB board only) WxHxD
Weight (PCB board only)
NX-7002 Installation manual
Page 34
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
APPENDIX 1: REPORTING FIXED CODES IN CONTACT-ID AND
SIA
The table below lists the event codes sent for the following reports (if enabled) when using Contact ID or SIA
formats.
REPORT
CONTACT ID
601
602
401
401
406
412
627
628
401
457
605
354
333
333
351
351
321
321
312
312
309
309
301
301
137
137
137
120
121
121
110
100
381
381
384
384
380
380
137
137
570
570
451
SIA
RX
RP
OP
CL
OC
RS
LB
LX
CR
EE
JL
MANUAL TEST
AUTOTEST
OPEN (User Number)
CLOSE (User Number)
CANCEL (User Number)
DOWNLOAD COMPLETE
START PROGRAM
END PROGRAM
RECENT CLOSE (User Number)
EXIT ERROR (User Number)
EVENT LOG FULL
FAIL TO COMMUNICATE
RT
ET
ER
LT
EXPANDER TROUBLE (device number)
EXPANDER RESTORE (device number)
TELEPHONE FAULT
TELEPHONE RESTORE
LR
YA
YH
YP
YQ
YT
SIREN TAMPER
SIREN RESTORE
AUX POWER OVERCURRENT (device number)
AUX POWER RESTORE (device number)
LOW BATTERY (device number)
LOW BATTERY RESTORE (device number)
AC FAIL (device number)
YR
AT
AR
TA
TR
TA
PA
HA
HA
FA
MA
*T
AC RESTORE (device number)
BOX TAMPER (device number)
BOX TAMPER RESTORE (device number)
KEYPAD TAMPER
KEYPAD PANIC (audible)
KEYPAD PANIC (silent)
DURESS
KEYPAD AUXILIARY 1
KEYPAD AUXILIARY 2
RF SENSOR LOST (zone number)
RF SENSOR RESTORE (zone number)
SENSOR LOW BATTERY (zone number)
SENSOR BATTERY RESTORE (zone number)
ZONE TROUBLE (zone number)
ZONE TROUBLE RESTORE (zone number)
ZONE TAMPER (zone number)
ZONE TAMPER RESTORE (zone number)
ZONE BYPASS (zone number)
BYPASS RESTORE (zone number)
EARLY OPEN / LATE CLOSE
*R
XT
XR
*T
*R
TA
TR
*B
*U
OK
NX-7002 Installation manual
Page 35
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
REPORT
CONTACT ID
SIA
CI
FAIL TO CLOSE
454
391
391
344
344
393
393
ZONE ACTIVITY FAULT
ZONE ACTIVITY RESTORE
RF JAMMING
NA
NS
XQ
XH
YX
RF JAMMING RESTORE
SMOKE DETECTOR CLEAN ME
SMOKE DETECTOR CLEAN ME RESTORE
YZ
THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS THE ZONE NUMBER. IF
THERE ARE NO PARENTHESES, THE ZONE WILL BE “0”. * The character transmitted in this slot will be the first character from the
event code of the zone that is bypassed or in trouble.
SPECIAL REPORTS
CONTACT ID
SIA
FAIL TO COMMUNICATE TCP/IP or SMS
GSM network failure (RSSI value to low)
354
354
RT002
RT078
NX-7002 Installation manual
Page 36
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
APPENDIX 2: OPERATOR ID CODES
This appendix provides a list of operator codes and the associated operator name.
Operator name
Network name
ID code
On mobile phone
Belgium
Proximus Belgacom Mobile
Mobistar
Proximus
Mobistar
Base
20601
BEL PROXIMUS
20610
20620
B Mobistar
Base
Base
Denmark
TDC Mobil A/S
TDC Mobil
SONOFON
3 DK
23801
23802
23806
23820
23830
DK TDC
SONO
3 DK
Sonofon
Hi3G Denmark ApS
Telia A/S Denmark
Orange A/S
TELIA DK
Orange
TELIA
Orange
France
Orange France
Orange F
SFR
20801
20810
20820
F-FT
SFR
SFR
Bouygues Telecom
Germany
Bouygues Telecom
BOUYGTEL
T-Mobile Deutschland GmbH
Vodafone D2 GmbH
E-Plus Mobilfunk GmbH
O2 (Germany) GmbH & Co
Italy
D1
26201
26202
26203
26207
TMO D
Vodafone
E-Plus
E-Plus
OHG O2(Germany) GmbH & Co. OHG
o2 - de
Telecom Italia Mobile
Vodafone Omnitel N.V
Wind Telecomunicazioni SpA
H3G
Telecom Italia Mobile
Vodafone
22201
22210
22288
22299
TIM
voda IT
I WIND
3ITA
Wind Telecomunicazioni SpA
H3G
Ireland
Vodafone Ireland Plc
O2 Communications (Ireland) Ltd
METEOR
Vodafone
27201
27202
27203
IRL Voda, Eircell, Eir Gsm
O2 - IRL
O2 Communications (Ireland) Ltd
METEOR
METEOR
Jersey, Guernsey and Isle of Man
Jersey Telecom
JT GSM
23450
23455
23458
JT GSM
C&W
Cable & Wireless Guernsey Ltd
Manx Telecom
Cable & Wireless Guernsey
Pronto GSM
Pronto
Netherlands
Vodafone Libertel N.V
KPN Mobile The Netherlands BV
TELFORT B.V.
Vodafone
20404
20408
20412
20416
20420
voda NL
KPN Mobile The Netherlands BV
TELFORT B.V.
NL PTT, NL KPN
NL Tlfrt
T-Mobile Netherlands
Orange Nederland N.V.
Norway
T-Mobile NL
TMO NL
Orange Nederland N.V.
Orange
Telenor Mobil
TELENOR
NetCom
24201
24202
TELENOR
N COM
NETCOM AS
Poland
Polkomtel S.A
PLUS GSM
Era
26001
26002
26003
PL-PLUS
Polska Telefonia Cyfrowa
PTK Centertel
Era
IDEA
IDEA, PL IDEA or PL 03
Portugal
Vodafone Portugal
Optimus Telecomunicacoes, S.A
Telecomunicacoes Moveis Nacionais S.A
Vodafone
OPTIMUS
TMN
26801
26803
26806
voda P
P03, P OPTIMUS, OPTIMUS
P TMN, P TELEMOVEL
NX-7002 Installation manual
Page 37
09/02/05
Download from Www.Somanuals.com. All Manuals Search And Download.
Operator name
Network name
ID code
On mobile phone
Spain
Vodafone Espana S.A.
Retevision Movil S.A
Telefonica Moviles Espana S.A.
Sweden
Vodafone
AMENA
21401
E VODAF
21403
21407
RET MOV, E 03, AMENA
MSTAR
MOVISTAR
TeliaSonera Mobile
HI3G Access AB
TELIA MOBILE
3
24001
24002
24007
24008
24010
TELIA
3
Tele 2 AB
COMVIQ
Vodafone
Swefour AB
IQ
Vodafone Sverige AB
Swefour AB
voda SE
Spring
United Kingdom
O2 (UK) Limited
O2
23410
23415
23420
23430
23431
23432
23433
O2 -UK
Voda
Vodafone Ltd
Vodafone
3
Hutchison 3G UK Ltd
T-Mobile (UK) Limited
T-Mobile (UK) Limited
T-Mobile (UK) Limited
Orange PCS Ltd
3 UK
T-Mobile UK
T-Mobile UK
T-Mobile UK
Orange
TMO UK
TMO UK
TMO UK
Orange
NX-7002 Installation manual
Page 38
Download from Www.Somanuals.com. All Manuals Search And Download.
09/02/05
EMEA Distribution is a division of GE Security EMEA bvba
COPYRIGHT ©2005
© GE Security EMEA bvba. All rights reserved. GE Security EMEA bvba grants the right to reprint this manual for