Furuno SONAR FSV 24 User Manual

Back  
Installation Manual  
COLOR SCANNING SONAR FSV-24/24S  
SAFETY INSTRUCTIONS...........................................................................i  
SYSTEM CONFIGURATION .....................................................................iii  
EQUIPMENT LISTS ...................................................................................v  
1. MOUNTING THE EQUIPMENT........................................................ 1-1  
1.1 Mounting the Hull Unit......................................................................................................1-1  
1.2 Mounting the Display Unit ................................................................................................1-8  
1.3 Mounting the Transceiver Unit........................................................................................1-14  
1.4 Mounting the Power Supply Unit ....................................................................................1-14  
1.5 Grounding the Equipment ..............................................................................................1-15  
1.6 Installing Attachment Flange (option) .............................................................................1-15  
1.7 Mounting the Cable for Extension Kit (option) ................................................................1-18  
1.8 Attachment Kit (option)...................................................................................................1-19  
2. WIRING............................................................................................ 2-1  
2.1 How to Use the Crimping Tool, Pin Extractor....................................................................2-1  
2.2 Location of Connectors ....................................................................................................2-2  
2.3 Monitor Unit .....................................................................................................................2-4  
2.4 Processor Unit .................................................................................................................2-8  
2.5 Transceiver Unit.............................................................................................................2-14  
2.6 Power Supply Unit .........................................................................................................2-17  
2.7 Cable for Extension Kit...................................................................................................2-17  
3. ADJUSTMENT AND CHECK........................................................... 3-1  
3.1 Hull Unit Check ................................................................................................................3-1  
3.2 Heading Adjustment.........................................................................................................3-4  
3.3 Configuring Own Ship Mark .............................................................................................3-6  
3.4 Other SYSTEM Menu Items.............................................................................................3-8  
3.5 CONE Board Setting in the Processor Unit ....................................................................3-12  
3.6 DIP Switch Setting .........................................................................................................3-13  
3.7 Testing TX/RX Independently at hull unit........................................................................3-15  
4. CONNECTING THE EXTERNAL INTERFACE CS-120A................. 4-1  
Check List............................................................................................AP-1  
PACKING LISTS ....................................................................................A-1  
OUTLINE DRAWINGS ...........................................................................D-1  
INTERCONNECTION DIAGRAMS......................................................... S-1  
www.furuno.co.jp  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INSTRUCTIONS  
WARNING  
DANGER  
Install the specified transducer tank  
in accordance with the installation  
instructions. If a different tank is to be  
installed the shipyard is solely respon-  
sible for its installation, and it should  
be installed so the hull will not be  
damaged if the tank strikes an object.  
Keep away from moving  
shaft of the hull unit.  
Gears may cause injury.  
The tank or hull may be damaged if the  
tank strikes an object.  
WARNING  
Do not open the cover  
unless totally familiar with  
electrical circuits and  
service manual.  
If a steel tank is installed on a wooden  
or FRP vessel, take appropriate  
measures to prevent electrolytic  
corrosion.  
Electrolytic corrosion can damage the  
hull.  
High voltage exists inside the  
equipment, and a residual  
charge remains in capacitors  
several minutes after the  
power is turned off. Improper  
handling can result in electri-  
cal shock.  
Be sure that the power supply is  
compatible with the voltage rating of  
the equipment.  
Connection of an incorrect power supply  
can cause fire or equipment damage. The  
voltage rating of the equipment appears  
on the label above the power connector.  
Turn off the power at the switchboard  
before beginning the installation.  
Fire or electrical shock can result if the  
power is left on.  
Do not install the equipment where it  
may get wet from rain or water splash.  
CAUTION  
Ground the equipment to  
prevent electrical shock and  
mutual interference.  
Water in the equipment can result in fire,  
electrical shock or equipment damage.  
Be sure no water leaks in at the trans-  
ducer installation site.  
Water leakage can sink the vessel. Also  
confirm that the transducer will not loosen  
by ship's vibration. The installer of the  
equipment is solely responsible for the  
proper installation of the equipment.  
FURUNO will assume no responsibility for  
any damage associated with improper  
installation.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Maximum speed while the transducer is  
projected and being raised or lowered  
is as below, to prevent damage to the  
transducer.  
Projected Raising/  
Lowering  
1200 mm stroke Max. 18 kt Max. 15 kt  
1600 mm stroke Max. 15 kt Max. 12 kt  
Observe the following compass safe  
distances to prevent interference to a  
magnetic compass:  
Standard  
compass  
Steering  
compass  
Processor Unit  
Control Unit  
Monitor Unit  
1.55 m  
0.20 m  
1.25 m  
1.05 m  
0.15 m  
0.85 m  
Other equipment should be positioned at  
least 7 m away from a magnetic compass.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM CONFIGURATION  
Standard type  
CONTROL UNIT  
FSV-2401  
MONITOR  
UNIT  
FSV-2400  
Local Supply  
Option  
AD Converter  
AD-10  
Gyrocompass  
Loudspeaker  
Sub Monitor  
Current  
Indicator  
Current  
Indicator/Log  
Echo Sounder,  
Current Indicator,  
other  
E/S Interface  
VI-1100A  
PROCESSOR UNIT  
FSV-2402  
Navigator 1  
Navigator 2  
Net Recorder  
VI-1100A  
VI-1100A  
External  
Net Sonde  
Junction Box  
CS-170  
Interface CS-120A  
(already installed)  
Note 1  
Net Sonde  
100/110/115/  
220/230 VAC,  
1φ, 50/60 Hz  
Cable for  
Extension Kit  
FSV-2451  
FSV-2452  
POWER  
SUPPLY  
UNIT  
TRANSCEIVER  
UNIT  
220 VAC,  
3φ, 50/60 Hz  
FSV-241E  
FSV-242  
Hull unit  
Specifications  
FSV-247  
1200 mm stroke  
FSV-248  
1600 mm stroke  
HULL UNIT  
100/110/115/  
220/230 VAC,  
1φ, 50/60 Hz  
Note 1: Power Kit FSV-2403 (option, installed in  
processor unit) required to connect CS-120A.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Black box type  
CONTROL UNIT  
FSV-2401  
Monitor  
Local Supply  
Option  
AD Converter  
AD-10  
Gyrocompass  
Loudspeaker  
Current  
Sub Monitor  
Indicator  
Current  
Indicator/Log  
Echo Sounder,  
Current Indicator,  
other  
E/S Interface  
VI-1100A  
PROCESSOR UNIT  
FSV-2402  
Navigator 1  
Navigator 2  
Net Recorder  
VI-1100A  
External  
VI-1100A  
Net Sonde  
Junction Box  
CS-170  
Interface CS-120A  
(already installed)  
Note 1  
Net Sonde  
100/110/115/  
Cable for  
Extension Kit  
FSV-2451  
FSV-2452  
220/230 VAC,  
1φ, 50/60 Hz  
POWER  
SUPPLY  
UNIT  
TRANSCEIVER  
UNIT  
220 VAC,  
3φ, 50/60 Hz  
FSV-241E  
FSV-242  
Hull unit  
Specifications  
FSV-247  
1200 mm stroke  
1600 mm stroke  
HULL UNIT  
(Select one.)  
FSV-248  
100/110/115/  
220/230 VAC,  
1φ, 50/60 Hz  
Note 1: Power Kit FSV-2403 (option, installed in  
processor unit) required to connect CS-120A.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EQUIPMENT LISTS  
Standard supply  
Name  
Monitor Unit  
Control Unit  
Type  
Code No.  
Q’ty  
1
1
Remarks  
21” color monitor  
w/cable  
For FSV-24  
For FSV-24S  
FSV-2400  
FSV-2401  
FSV-2402  
FSV-2402S  
FSV-241E  
FSV-242  
-
-
-
Processor Unit  
1
Transceiver Unit  
Power Supply Unit  
-
-
-
-
1
1
FSV-247  
FSV-248  
1200 mm stroke  
1600 mm stroke  
Hull Unit  
1*  
For system with monitor  
CP10-04501, 10S2074,  
CP10-04502, CP10-04503,  
CP10-04505, CP10-04506,  
10S2078  
CP10-05100 000-067-027  
For system with monitor  
CP10-04501, 10S2075,  
CP10-04502, CP10-04503,  
CP10-04505, CP10-04506,  
10S2078  
For system without monitor  
CP10-04502, CP10-04503,  
CP10-04505, CP10-04506,  
10S2078  
Installation Materials  
1 set*  
CP10-05110 000-067-028  
CP10-05120 000-067-029  
SP10-02601, SP1-02602,  
SP10-02603  
FP03-06201, FP10-02202,  
FP10-02201, FP10-02203,  
Spare Parts  
Accessories  
SP10-02600 000-066-999 1 set  
FP10-02200 000-067-006  
FP10-02210 000-067-007  
1 set dust cover  
For system without monitor  
FP10-02201, FP10-02203  
*: Select one  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Options  
Name  
Monitor Unit  
Type  
FSV-2400-10  
Code No.  
-
Q’ty  
1
Remarks  
With CP10-04501,  
FP03-06201, FP10-02202,  
Dust cover & 10S5207 (10 m  
cable)  
FSV-2400-30  
With CP10-04501,  
FP03-06201, FP10-02202,  
Dust cover & 10S2075 (30 m  
cable)  
-
Control Unit  
FSV-2401-E-5  
FSV-2401-E-10  
With FP10-02201 & 5 m  
cable  
With FP10-02201 & 10m  
cable  
-
-
1
37 cores Cable  
E/S Interface  
Net Zonde Junction CS-170  
Box  
10S1258  
VI-1100A  
000-101-006  
1
1
1
Specify length  
-
-
For sonde connection  
For connection of  
CS-120A  
10 m, 6P-6P  
5 m, 6P-6P  
6 m  
Power Supply Kit  
NMEA Cable  
FSV-2403  
000-067-013  
1
MJ-A6SPF0012-100C 000-154-037-10  
MJ-A6SPF0012-050C 000-154-053-10  
VVS 0.3X8C *6M*  
1
1
1
E/S cable  
000-555-043  
For CSH-20 1200 mm  
stroke w/flange, FSV-247  
For CSH-20 1600 mm  
stroke w/flange, FSV-248  
Using retraction tank of  
FSV-243E/244E for  
FSV-247/248  
OP10-22  
000-067-037  
1
1
Attachment Flange  
OP10-23  
OP10-24  
000-067-038  
006-943-530  
Attachment Kit  
1
Loudspeaker  
Hood  
SEM-21Q  
FP03-06503  
000-144-917  
008-490-970  
1
1
For monitor unit  
Installation Material  
for interface  
Cable for  
CP10-04801  
FSV-2451  
006-934-240  
1
1
5 m cable extension,  
10S2138*5m*,  
10S2139*5m*,  
10S2144*12.9m*  
15 m cable extension,  
10S2138*15m*,  
10S2139*15m*,  
10S2145*22.9m*  
Extension Kit  
000-067-030  
FSV-2452  
000-067-031  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. MOUNTINGTHE EQUIPMENT  
1.1  
Mounting the Hull Unit  
Note1) The rise/lower control box of the hull unit contains motion sensor.  
Therefore, never drop the hull unit.  
Note2) Take care the handling of the transducer. Do not give a strong shock.  
1.1.1  
Location of hull unit  
Decide the location of the hull unit through consultation with the dockyard and  
ship owner. When deciding the location, the following points should be taken into  
account.  
Select an area where propeller noise, cruising noise, air bubbles and  
interference from turbulence are at a minimum. Generally, the point at 1/3 to  
1/2 of the ship’s length from the bow on or near the keel is optimum.  
On-the-keel installation is advantageous for minimizing oil consumption in  
comparison with off-the-keel. If the hull unit can not be installed on the keel,  
the center of the retraction tank should be within 600 mm of the keel to  
prevent a rolling effect. For large ship with deep draft, the hull unit can be  
installed at the bow.  
1/3  
1/2  
Within 600 meter  
Hull unit mounting location  
Select a place where the hull bottom is flat and the draft is sufficiently deep.  
Normally, the transducer should protrude at least 500 mm beyond the keel to  
minimize the effect of air foam and bubbles.  
Select a place where interference from other equipment is minimal. The hull  
unit should be at least 2.5 m away from the transducers of other equipment.  
No obstacle should be in the fore direction since it causes a shadow zone and  
aerated water, resulting in poor sonar performance.  
The space shown in the figure on the next page is required around the hull  
unit for wiring and maintenance.  
If the ambient temperature of the unit is below 0°C, provide the sonar  
compartment with a heater to keep the temperature above 0°C.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1300  
650  
Heater Insulator  
Maintenance space, example sonar compartment  
Note: After mounting the equipment, install stays for anti-vibration. See page  
1-7.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.2  
Shortening the retraction tank  
The retraction tank is 1300 mm in length when supplied. Shorten the tank as  
necessary so that the transducer is placed well below the keel when it is fully  
lowered. The following table provides guidelines for shortening the tank. Refer  
also to the retraction tank installation drawing at the back of this manual.  
Installation  
Method  
D
Same as left.  
Same as left.  
D
XDCR Travel  
Remove 130  
thru 140 mm  
from the  
Remove 130 to 140 mm  
from the bottom.  
Note that the length  
"D" must be less than  
1170 mm.  
Same as left.  
1200 mm  
stroke  
bottom.  
Remove less than  
140 mm from the  
bottom. Note that the  
length "D" must be less  
than 1570 mm.  
Remove  
less than  
140 mm  
from the  
bottom.  
Same as left.  
1600 mm  
stroke  
Guidelines for shortening the retraction tank  
Note 1: In the 1200 mm stroke type hull unit, the transducer will not fully  
protrude unless the tank is shortened by at least 130 mm from the  
bottom, and cannot be fully retracted if more than 140 mm is removed.  
Note 2: In the 1600 mm stroke type hull unit, the transducer cannot be fully  
retracted if the tank is removed more than 140 mm.  
Note 3: When 140 mm is removed and “D” is minimum, the effect of air foam is  
minimized because the transducer fully protrudes in water.  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.3  
Remarks for installation of retraction tank  
1. Make, if possible, the installation location a double bottom structure.  
2. Install, if possible, the tank on the keel where the tank can be most firmly  
fixed.  
3. Install the reinforcement ribs as near as possible to the top of the retraction  
tank, allowing space for tightening of bolts and nuts.  
Retraction tank  
Reinforcement rib  
250-300 mm  
How to install reinforcement ribs  
4. Add a doubling plate at the location where the retraction tank is welded to the  
hull bottom. The size of the doubling plate is normally 1300 mm in diameter  
so that it may lie across two bottom frames.  
5. Make the bow mark on the attachment flange with a chisel.  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.4  
Installing hull unit on retraction tank  
After welding the retraction tank and allowing sufficient time for cooling, install  
the hull unit as follows.  
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a  
slight amount of grease. Place the O-ring in position on the tank flange.  
2. Orient the hull unit so that the bow mark (inscribed) on its flange points  
toward the ship’s bow. Note that heading adjustment in the display unit is  
required if the bow mark does not face the ship’s bow.  
3. Confirm that the O-ring is in position. Place the hull unit on the tank.  
4. Coat every bolt, washer and nut with a slight amount of grease to ease  
removal. Fasten the hull unit to the retraction tank with flat washers, spring  
washers and hex bolts.  
5. Reinforce the hull unit against vibration by extending stays to the ship’s hull  
from the two eye bolts at the top of the hull unit, referring to the figure at the  
top of page 1-7.  
1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hex. Nut  
Spring Washer  
Flat Washer  
Bow Mark  
Hull Unit Flange  
O-ring  
Tank Flange  
Flat Washer  
Hex. Bolt  
Hex. Nut  
Spring Washer  
O-ring  
Flat Washer  
O-ring  
Retraction Tank  
Flat Washer  
Hex. Bolt  
Hex. Nut  
Spring Washer  
Stern side (seven locations)  
Bow side (17 locations)  
Installation of hull unit  
1-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.5  
Installing stays (anti-vibration measure)  
Install stays from the top of the hull unit to the ship’s hull. The stays should be  
angle iron with a size of 75X75X9 mm or more and at least two pieces should be  
used; one each to ship’s bow and stern directions. Install if possible, two more  
stays in ship’s transverse direction.  
Bow  
Stay  
Stay  
Hull Unit  
Proper installation of stays  
Do not install the stays as shown below. Vibration-resistance effect is reduced  
since vibration is applied to the stays as rotation force. Install them horizontally.  
Crossbeam  
on ceiling  
(wrong installation method)  
Stay  
Eye Bolt  
Proper installation  
Hull Unit  
90  
Proper and wrong installation of stay  
Note:Install stays as shown above, otherwise the transducer may be damaged.  
1-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2  
Mounting the Display Unit  
The display unit is composed of the processor, monitor and control units.  
1.2.1  
Processor unit  
Mounting considerations  
When selecting a mounting location, keep in mind the following points:  
The processor unit must be mounted upright.  
Locate the unit out of direct sunlight and away from heat sources because of  
heat that can build up inside the cabinet.  
Locate the equipment away from places subject to water splash and rain.  
Be sure the mounting location is strong enough to support the weight of the  
unit under the continued vibration which is normally experienced on the ship. If  
necessary reinforce the mounting location.  
Determine the mounting location considering the length of the cables below.  
a)Signal cable from the transceiver unit  
b)Monitor cable from the monitor  
c) Control cable from the control unit (when locally supplied monitor is used)  
Leave sufficient space on the sides and rear of the unit to facilitate  
maintenance. Also, leave a foot or so of "service loop" in cables behind the  
unit so it can be pulled forward for servicing or easy removal of connectors.  
Make free space of 400 mm between the processor unit and bulkhead to  
prevent cable stress.  
Cable fixing hole  
1-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting procedure  
1. Unfasten two bolts from the bottom of the front side of the processor unit, and  
pull the unit toward you to separate the unit from the mounting base.  
2. Fasten six bolts (M6x20, supplied as installation material) to install the  
mounting base.  
3. Place the processor unit in front of the mounting base.  
4. Push the unit forward until it touches the end of the mounting base.  
5. Refasten two bolts removed at step 1 to fix the unit.  
505  
477  
5.5  
34  
8
200+1  
195+1  
Top view  
Processor unit  
Front view  
1.2.2  
Monitor unit  
Mounting considerations  
The monitor unit is designed for mounting on a tabletop.  
Locate the monitor unit where it can be easily operated while viewing the  
screen and operating the control unit.  
Locate the monitor unit out of direct sunlight and away from heat sources  
because of heat that can build up inside the cabinet.  
Locate the equipment away from places subject to water splash and rain.  
Be sure the mounting location is strong enough to support the weight of the  
unit under the continued vibration which is normally experienced on the ship. If  
necessary reinforce the mounting location.  
The length of the monitor cable which runs between the processor unit and the  
monitor unit is 10 m. Keep this distance in mind when selecting a mounting  
location.  
Leave sufficient space on the sides and rear of the unit to facilitate  
maintenance.  
1-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting procedure  
1. Drill four holes of 12 mm in diameter in the mounting location, referring to the  
outline drawing for mounting dimensions.  
2. Unfasten two M4X10 screws to dismount the front cover.  
3. Unfasten two sets of M10 bolts, plain washers and spring washers to  
separate the monitor from the mounting base.  
4. Pull the monitor forward about four centimeters and then lift it to separate it  
from the mounting base.  
5. Fasten the mounting base to the mounting location with M10 bolts, nuts and  
washers (local supply).  
6. Lay the monitor on the top of the mounting base, making sure the rear pin on  
the monitor is mated to the slit in the mounting base. Fix the monitor to the  
mounting base with the two sets of bolts, nuts and washers unfastened at  
step 3.  
7. Close the front cover.  
Plain Washer, M10, 2 pcs.  
Spring Washer, M10, 2 pcs.  
Pin  
Hex Bolt  
M10X30,  
2 pcs.  
Hex Bolt  
M10X30, 4 pcs.  
Washer  
Front Cover  
Pan-Head Screw  
M4X10, 2 pcs.  
Slit  
Mounting Base  
Monitor unit  
1-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Attaching the CRT filter  
1. Attach two spacer (5x2.5, supplied) with screws (M5x10, supplied) to the  
location shown below.  
2. Screw two hood retainer (supplied) into the filter (supplied).  
3. Turn two washers (Ф12, supplied) into two hood retainer attached at step 2.  
4. Attach the filter to the monitor unit as shown below.  
Hood retainer (2 pcs.)  
Washer (2 pcs.)  
Filter  
M5  
tapping hole  
(Up side)  
CRT  
Notch  
(Down side)  
Spacer (2 pcs.)  
Screw (2 pcs.)  
How to attach the hood  
1.2.3  
Control unit  
The control unit may be mounted on a tabletop, with or without the KB fixing  
plate (supplied), which mounts the control unit at an angle. If the control unit is  
not to be fastened, lay it atop the rubber feet (supplied as accessory).  
(1) Rubber feet  
Attach four rubber feet to the bottom of the control unit if it is not going to be  
permanently fixed.  
1-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
(2) Fixing without KB fixing plate  
1) Drill four mounting holes of 6 mm diameter to fasten the control unit,  
referring to the outline drawing at the back of this manual.  
2) Make a cutout in the mounting location large enough to accommodate the  
name plate so the control unit will lie flat. For dimensions, see the outline  
drawing at the back of this manual.  
3) Fix the control unit with four bolts (M5) from under the tabletop. (M5 bolts  
with a sufficient length for the thickness of the tabletop should be provided  
locally.)  
Control unit  
(3) Using KB fixing plate mounting  
1. To fix the control unit to a desired location at an angle, fasten the KB fixing  
plate to the control unit and desired location with two upset screws (M5X10,  
supplied) and two tapping screws (φ6.5, local supply) as below.  
How to attach KB fixing plate  
2. Set dust cover (supplied) to the control unit.  
1-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Passing the cable through the bottom of the control unit  
For permanent mounting ((2) and (3) above), the control cable can be passed  
through the bottom of the control unit. Do the steps in below.  
1. Unfasten eight screws (M4) to remove the cover from the bottom of the  
control unit.  
2. Unscrew two screws (M4x10) to remove the cable clamp.  
3. Disconnect two connectors J1 and J2 from the circuit board.  
4. Attach the cable to the control unit cover with the cable clamp (removed at  
step 2), two flat head screws (M4), flat washers, spring washers and nuts  
(hardware: supplied).  
Screw  
M4X8 (8 pcs.)  
Previous cable hole  
Nut  
Clamp  
Spring washer  
Flar washer  
Flat head screw  
Fasten the cable with the clamp here.  
Control unit, cover removed  
5. Re-connect two connectors (disconnected at step 3) to the previous  
locations.  
6. Fasten eight screws to attach the control unit cover.  
7. Attach the connector seal (supplied) to the hole at the rear of the control unit.  
8. Drill a hole to pass the cable from the bottom of the control unit through the  
tabletop. The diameter of the hole should be 30 mm.  
9. Attach the connector seal (supplied) to the hole at the bottom of the control  
unit when the above modification is not done.  
10. Fix the control unit referring to (2) or (3) on the previous page.  
Cable  
Cable  
w/o KB fixing plate  
w/ KB fixing plate  
Control unit, side view  
1-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3  
Mounting theTransceiver Unit  
The transceiver unit should be mounted on a mounting base (shipyard supply)  
whose dimensions are as shown in the outline drawing of the transceiver unit at  
the back of this manual. The transceiver unit should be reinforced against  
vibration by stays extending from the eyebolts on the top of the unit. Fasten 10  
bolts (M12, local supply) at the bottom and back of the transceiver unit to fasten  
it to the mounting location.  
Transceiver unit  
1.4  
Mounting the Power Supply Unit  
Weld four bolts (M8, local supply) referring to the outline drawing at the back of  
this manual. Sets the power supply unit to the bolts welded, and then turn four  
nuts (local supply) to fix.  
Note: If necessary, reinforce the bulkhead since the unit weights 25 kg (57.3  
lbs).  
Power supply unit  
1-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.5  
Grounding the Equipment  
The power supply unit, processor unit and hull unit have protective grounding.  
Ground the units with a ground wire (IV-8SQ, local supply) or copper strap to  
prevent electrical shock. Ground the monitor unit and transceiver unit with a  
ground wire (IV-8SQ, local supply) or copper strap fastened to the ship’s  
superstructure. For the power supply unit, transceiver unit and junction box  
(option) use a supplied copper strap.  
Grounding for junction box  
Use one of four butterfly bolts to ground the junction box.  
1.6  
Installing Attachment Flange (option)  
The tank for the CSH-20 series may be used by installing the optional  
attachment flange.  
In case that 1200 mm stroke was used in CSH-20 series  
Attachment flange set  
For FSV-247: OP10-22 (Code no: 000-067-037)  
Name  
Type  
Code No.  
100-303-601  
Q’ty  
1
Remarks  
Attachment flange 10-077-5801  
O-ring  
CO 0318A (V585)  
000-166-370-10  
1
Hex. bolt  
Hex. nut  
Flat washer  
Spring washer  
M20x120 SUS304 000-162-825-10  
24  
48  
48  
24  
M20 SUS304  
M20 SUS304  
M20 SUS304  
000-863-116  
000-864-136  
000-864-270  
In case that 1600 mm stroke was used in CSH-20 series  
Attachment flange set  
For FSV-248: OP10-23 (Code no. 000-067-038)  
Name  
Type  
Code No.  
100-303-610  
000-166-370-10  
000-863-116  
000-864-136  
000-864-270  
Q’ty  
1
1
48  
24  
24  
Remarks  
Attachment flange 10-077-5802  
O-ring  
CO 0318A (V585)  
Hex. nut  
Flat washer  
Spring washer  
M20 SUS304  
M20 SUS304  
M20 SUS304  
1-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Procedure  
1. Clean the hull unit flange, O-ring and O-ring groove. Coat them with a slight  
amount grease.  
2. (1200 mm stroke) Use 24 hex. bolts, 48 hex nuts, flat washers and spring  
washers to fasten the attachment flange to retraction tank.  
(1600 mm stroke) 24 bolts have already been fitted. Use the bolts, 48 hex.  
nuts, flat washers and spring washers to fasten the attachment flange to  
retraction tank.  
3. Place the O-ring in position on the attachment flange.  
To install the attachment flange and the hull unit, see “1.1.4 Installing hull unit on  
retraction tank” on page 1-5.  
The sectional view for the attachment flanges are shown on the next two pages.  
Hex. Bolt  
Flat Washer  
Hull Unit Flange  
O-ring  
Flat Washer  
Spring Washer  
Hex. Bolt  
Hex.  
Flat Washer (M20)  
Nut  
Attachment Flange  
O-ring  
Existing Tank  
Flat Washer  
Spring Washer  
Hex. Nut  
Attachment flange for 1200 mm stroke transducer, sectional view  
1-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hex. Bolt  
Flat Washer  
Hull Unit Flange  
O-ring  
Flat Washer  
Spring Washer  
Hex. Nut  
Attachment Flange  
O-ring  
Existing Tank  
Flat Washer  
Spring Washer  
Hex. Nut  
*: FSV-244E only  
Attachment flange for 1600 mm stroke transducer, sectional view  
1-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.7  
Mounting the Cable for Extension Kit (option)  
For extension of the transducer cable between the hull unit and the transceiver  
unit, use the extension cable kit (option). The kit is available in 5 and 15 meter  
lengths.  
Name: Cable for Extension Kit, Type: FSV-2451, Code No.: 000-067-030  
Name  
Type  
Code No.  
Qty Remarks  
Junction box  
FSV-245  
10S2138*5m*  
10S2139*5m*  
000-067-032  
000-145-350  
000-145-354  
1
1
1
1
Cable assembly  
10S2144*12.9m* 000-145-360  
Name: Cable for Extension Kit, Type: FSV-2452, Code No.: 000-067-031  
Name  
Type  
Code No.  
Qty Remarks  
Junction box  
FSV-245  
10S2138*15m*  
10S2139*15m*  
000-067-032  
000-145-351  
000-145-355  
1
1
1
1
Cable  
assembly  
10S2144*22.9m* 000-145-361  
Fasten the Junction Box to bulkhead with 4 bolts (M8, local supply).  
Junction box  
1-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.8  
Attachment Kit (option)  
When using the retraction tank of FSV-243E/244E for FSV-247/248, the optional  
attachment kit OP10-24 is necessary.  
Name: Attachment kit Type: OP10-24 Code no.: 006-943-530  
Name  
Insulation gasket  
Insulation gasket (2) MS-1000-68  
Type  
MS-1000-67  
Code No.  
000-857-220  
000-857-221  
Qty  
24  
24  
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a  
slight amount of grease. Place the O-ring in position on the tank flange.  
2. Lay the insulation gasket (1) on the top of the tank flange.  
3. Orient the hull unit so that the bow mark (inscribed) on its flange points  
toward the ship’s bow. Note that heading adjustment in the display unit is  
required if the bow mark does not face the ship’s bow.  
4. Confirm that the O-ring and the insulation gasket (1) are in position.  
5. Place the hull unit on the tank.  
6. Seven of the 24 bolt holes on the hull unit flange have already been fitted  
with bolts (stern side). Insert the insulator gasket (2) into the bolt holes of the  
tank flange to which these seven bolts are fitted.  
7. Coat every bolt, washer and nut with a slight amount of grease to ease  
removal. Fit the insulation gasket (2) into the bolt holes of the tank flange.  
Fasten the hull unit to the retraction tank with insulation gasket (2), flat  
washers, spring washers and hex bolts.  
8. Reinforce the hull unit against vibration by extending stays to the ship’s hull  
from the two eye bolts at the top of the hull unit, referring to the figure at the  
top of page 1-7.  
1-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hex. nut  
Spring washer  
Flat washer  
Flange of the hull unit  
O-ring  
Flange of the hull unit  
O-ring  
Insulation gasket (1)  
Insulation gasket (1)  
Insulation gasket (2)  
Insulation gasket (2)  
Flat washer  
Flat washer  
Spring washer  
Hex. nut  
Hex. bolt  
Hex. bolt  
Spring washer  
O-ring  
Flat washer  
O-ring  
Insulation gasket  
Insulation gasket (2)  
Flat washer  
Retraction tank  
Hex. bolt  
Hex. nut  
Spring washer  
Bow side  
(17 locations)  
Stern side  
(Seven locations)  
Using the optional attachment kit  
1-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. WIRING  
2.1  
How to Use the CrimpingTool, Pin Extractor  
A special crimping tool is necessary for connection of wires to the contact pins of  
the 38P connector. The pin extractor removes the contact pin from the connector  
body. This paragraph describes how to crimp and extract the contact pin.  
Contact Pin  
60-8017-0313-00-339  
(000-519-542)  
Pin Extractor  
06-1877-04  
(000-519-595)  
Crimping Tool  
06-1001-016  
Crimping tool, contact pin, pin extractor  
2.1.1  
How to use the crimping tool  
1. Strip the vinyl sheath of the wire to  
expose the core by 3 mm to 4 mm.  
2. Hold the crimping tool horizontally and  
insert the contact pin with its slit facing  
downward into the crimp hole on the  
crimping tool.  
3. Insert the wire onto the contact pin and  
squeeze the handle until the rachet  
releases. (The wire should be placed  
deep enough into the contact pin so  
that its end comes in contact with the  
stopper plate of the crimping tool.) With  
crimping completed, pull the wire while  
holding the contact pin to make sure  
that it is tightly fastened.  
2.1.2  
How to use the pin extractor  
If a contact pin is inserted into an incorrect  
hole on the connector body, remove it with  
the pin extractor.  
1. Push the pin extractor into the pin hole  
from the side opposite to the pin  
inserting side.  
2
1
2. Push in the head of the pin extractor. The retaining spring comes free and the  
contact pin can be removed.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2  
Location of Connectors  
MONITOR UNIT  
10S2076 (5/10 m)  
FSV-2400  
10S2076 (5/10 m)  
CONTROL UNIT FSV-2401  
10S2074 (10 m) or 10S2075 (30 m)  
CONTROL UNIT FSV-2401  
Monitor  
(Local supply)  
Transceiver  
unit  
Monitor unit  
Control unit  
Monitor cable  
(Local supply)  
Monitor unit  
Control unit  
External  
monitor  
*2: If connector may loosen by  
vibration the monitor may also  
be connected inside.  
*2  
*3  
Processor unit clamp  
TRANSCEIVER UNIT  
FSV-241E  
PROCESSOR UNIT  
FSV-2402/2402S  
DPYCY-1.5  
100/110/115/  
220/230 VAC  
1φ, 50/60 Hz  
*4  
10S2078 (8 m)  
*5 *6  
POWER SUPLY UNIT  
FSV-242  
220 VAC  
3φ, 50/60 Hz  
*4  
*3  
TPYCY-4  
100/110/115/  
220/230 VAC  
1φ, 50/60 Hz  
HULL UNIT  
FSV-243E (1200 mm stroke)/  
FSV-244E (1600 mm stroke)  
*3  
DPYCY-4  
10S2140 (15 m), 10S2141 (14.5 m)  
*5 *6  
*3: Japan Industrial Standard cable  
*4: The same type of connector is fitted at each end, however the connector where the amount of sheath  
removed is greater should be connected to the transceiver unit.  
*5: When running the cables of 10S2078, 10S2140 and 10S2141, refer to next page.  
*6: When using cable for extension kit, the length of the cable between the transceiver unit  
and the hull unit is 10 m or 20 m.  
Interconnection  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Transceiver unit side  
0.38m  
1
0.07m  
Clamp point  
0.46m  
16  
1
0.48m  
0.5m  
*
7.2m  
16  
10S2078  
8m  
10S2141  
14.5m  
10S2140  
15m  
*
*
13.3m  
13.3m  
Clamp point  
0.07m  
0.28m  
Raise/lower control box  
of the hull unit side  
Hull unit side  
*: Cable length between the transceiver and hull unit.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3  
Monitor Unit  
2.3.1  
Fabrication of monitor cable 10S2074 (10 m)/10S2075 (30 m)  
SHIELD  
ANTICORROSIVE SHEATH  
11  
1
1. GRY (No.1)  
2. BLK/WHT  
3. GRY (No.2)  
4. BLK/RED  
5. GRY (No.3)  
6. BLK/GRN  
7. GRY (No.4)  
8. BLK/YEL  
17. WHT/BRN  
18. WHT/PPL  
19. RED/GRN  
20. RED/YEL  
21. RED/BLU  
22. RED/BRN  
23. RED/PPL  
24. GRN/YEL  
12  
2
9. GRY (No.5)  
10. BLK/BLU  
11. BLK/BRN  
12. BLK/PPL  
13. WHT/RED  
14. WHT/GRN  
15. WHT/YEL  
16. WHT/BLU  
30  
10  
25. GRN/BLU  
26. GRN/BRN  
27. GRN/PPL  
28.YEL/BLU  
29.YEL/BRN  
30.YEL/PPL  
13  
14  
29  
28  
15  
16  
17  
27  
26  
25  
9
8
3
4
7
5
6
18  
24  
19  
23  
20  
22  
21  
ARMOR  
1, 3, 5. 7, 9: Coaxial cables  
Others: Twisted pair cables  
10S2074, sectional view  
Fabrication of connector 00-8016-038-313761HV (CN-A303)  
250  
Anticorrosive  
45  
40  
Shield  
Sheath  
Vinyl Sheath  
Armor  
Core  
Insulating Tape  
After exposing cores,  
wind shield around the armor.  
Fabrication of connector 00-8016-038-313761HV  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Guide Pin A  
Guide Pin B  
Position No.  
Guide Pin A  
Guide Pin B  
(Small)  
(Large)  
Assembling 38P connector  
Positioning guide pins  
Guide pins of the connector identify the mating receptacle.  
They are;  
Guide pin A (Large): 4  
Guide pin B (Small): 1  
Assembling BNC connector (CN-A304 to 308)  
Clamp  
Housing  
Nut  
Washer  
Gasket  
1. Remove vinyl sheath of the cable by 7.5 mm.  
2. Pass the cable through the nut, washer, gasket  
and clamp.  
3. Unravel the shield and fold it back onto the  
clamp.  
4. Remove the insulator, leaving 3 mm.  
5. Trim the shield as shown in the drawing. Solder  
the center chip to the conductor of the cable.  
6. Pass the cable through the housing and tighten  
the nut.  
Center Pin  
7.5  
Shield  
3
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Assembling D-SUB connector (CN-A302)  
1. Remove vinyl sheath of cores by 3 mm.  
2. Pass the cores through shrink tubes (local supply).  
3. Solder cores to connector pins referring to the schematic diagram at the back  
of this manual.  
4. Assemble the connector.  
tube  
le clamp  
Assembling D-sub connector  
2.3.2  
Control cable  
For FURUNO-supplied monitor, attach the cable from the control unit to the  
CN-A301 connector on the monitor unit as shown in the next section. For  
blackbox type, this cable should be connected to the CN-A103 connector in the  
processor unit.  
2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.3  
How to connect cables to the monitor unit  
Connect the monitor cable and control cable to the monitor (FURUNO-supplied  
monitor) unit as below.  
1. Unfasten four screws (M4x10) at the rear of the monitor to loosen the cable  
cover.  
2. Lift and pull the cable cover to remove it.  
3. Unfasten two screws (M4x10) to remove the clamp cover.  
4. Lay the monitor and control cables on the clamp, and then reattach the  
clamp plate to fix cables.  
5. Connect eight connectors referring to the instruction sticker by the connector  
board.  
6. Reattach the cable cover.  
CN-A305 CN-A304  
CN-A306  
2
1
3
G
B
R
CN-A308 CN-A307  
5
4
CN-A302  
H
V
Connector board  
CN-A303  
CN-A301  
Monitor cable  
Control cable  
Clamp  
Cable cover  
Monitor unit, rear view  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4  
Processor Unit  
Cables (10S2074, 10S1258-1 and control cable) from the various units are  
connected to the CONE Board (10P6905) via the cable clamp (See page 2-2).  
CAUTION  
Divide cables attached to the back of the  
processor unit between right and left side.  
And then tie each group with a cable tie at  
the position 150 mm from connectors.  
This is necessary to prevent cable stress.  
15cm  
Cable tie  
2.4.1  
10S1258-1 cable  
This cable runs between the processor unit and transceiver unit.  
SHIELD  
ANTICORROSIVE SHEATH  
1. BLK  
17. BRN/GRY  
18. BRN/WHT  
19. RED/ORG  
9. BLK/GRY  
8
2
1
9
19  
2. BLK/BRN  
3. BLK/RED  
4. BLK/ORG  
5. BLK/YEL  
6. BLK/GRN  
7. BLK/BLU  
8. BLK/PPL  
10. BLK/WHT  
11. BRN/RED  
12. BRN/ORG  
13. BRN/YEL  
14. BRN/GRN  
15. BRN/BLU  
16. BRN/PPL  
10  
18  
17  
3
4
7
6
11  
12  
13  
5
16  
14  
15  
ARMOR  
1:  
Coaxial cable  
2 to 19: Twisted pair cable  
Cable type 10S1258-1, sectional view  
2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fabrication of connector 00-8016-038-313761HV (CN-A101)  
320  
Anticorrosive  
45  
40  
Shield  
Sheath  
Vinyl Sheath  
Armor  
Core  
Insulating Tape  
After exposing cores,  
wind shield around the armor.  
Fabrication of connector 00-8016-038-313761HV  
Guide Pin A  
Guide Pin B  
Position No.  
Guide Pin B  
(Small)  
Guide Pin A  
(Large)  
Assembling 38P connector  
Positioning guide pins  
Guide pins of the connector identify the mating receptacle.  
They are;  
Guide pin A (Large): 1  
Guide pin B (Small): 1  
2.4.2  
Power cable  
Attach the NCS-253-P connector (CN-A110) to the power cable DPYCY-1.5  
(Japan Industrial Standard (JIS) cable) or the equivalent for connection the  
ship’s mains.  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cable DPYCY-1.5  
Armor  
Vinyl  
sheath  
Conductor  
S = 1.5 mm  
Use cable DPYCY-1.5  
(Japan standard cable)  
or equivalent cable.  
2
= 1.56 mm  
Assembling connector NCS-253-P  
2.4.3  
2.4.4  
Monitor cable (10S2074 or 10S2075)  
Connect the monitor cable 10S2074 or 10S2075 (from the monitor unit) to the  
connectors in the processor unit shown below.  
38P connector:  
D-sub 25 pin:  
D-sub 15 pin:  
CN-A103 (For the optional sub-display, CN-A108)  
CN-A102 (For the optional sub-display, CN-A107)  
CN-A104 (For the optional sub-display, CN-A109)  
Control cable  
For blackbox type, attach the control cable (10S2076) to the CN-A103 connector  
in the processor unit. The control unit for the sub-display unit should be  
connected to the CN-A108 connector.  
2-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4.5  
Optional equipment  
With connection of navigator and electronic fishing equipment, the function of  
the FSV-24 is expanded to include true motion presentation, target lock, echo  
sounder picture, FNZ marker presentation and digital indication of position, water  
temperature and depth.  
Use the SRCN connectors (optionally supplied, Type: CP10-4801,  
Code no.: 006-934-240) to connect equipment to the rear of the processor unit  
referring to the interconnection diagram at the back of this manual.  
Cable list  
Outline of core  
Simple  
w/shield  
Twisted  
Schematic view of cables  
02S8040  
No.  
1
Color  
WHT/BLU  
BLK  
9 mm  
2
3
PNK  
Shield  
4
GRN  
5
ORG  
YEL  
6
7
RED  
CO-SPEVV-SB-C 0.2sq, 5P  
No.  
1
Color  
YEL/BLK  
2
YEL/WHT  
YEL/RED  
YEL/BLU  
Shield  
Armor  
14 mm  
3
4
5
YEL/GRN  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
J5 (CIF1)  
J7 (GYRO)  
J8 (LOG)  
J10 (FNZ)  
: SRCN6A13-5P  
: SRCN6A16-10P  
: SRCN6A13-3P  
: SRCN6A21-10P  
Cable with armor  
J13 (EXT-KP) : SRCN6A21-10S  
8 cm  
2 cm  
1 cm  
Armor  
Vinyl sheath  
Shield  
3 mm  
Clamp fixing screw  
Solder unused cores and  
earth to braided shield.  
Clamp  
Set screw  
Wind shield  
tape.  
Soldering  
Connector case  
Soldering side  
Clamp shielding tape with  
connector clamp for grounding.  
Wind vinyl tape.  
J9 (ES1)  
J12 (ES2/NET) : SRCN6A16-10P  
: SRCN6A16-7P  
Cable without armor  
2 cm  
3mm  
Shield  
Vinyl sheath  
Clamp fixing screw  
Solder unused cores and  
earh wire to braided shieeld.  
Clamp  
Set screw  
Vinyl sheath  
Wind vinyl tape  
Connector case  
Soldering-side  
2-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Synchronizing with echo sounder or other sonar  
To synchronize the transmission of the FSV-24 with an echo sounder or other  
type of sonar, make connections as shown below.  
For current driven KP input  
Processor  
unit  
EXT-KP  
KP signal  
8
9
E/S  
Sonar  
EXT-KP-IN-H  
EXT-KP-IN-C  
For voltage driven KP (12 V) input  
Processor  
unit  
EXT-KP  
KP signal  
10  
7
E/S  
Sonar  
EXT-12VKP-H  
0V  
Voltage driven KP output  
KP signal  
Processor  
unit  
EXT-KP  
1
2
3
4
5
6
INTKP1  
GND  
INTKP2  
GND  
INTKP3  
GND  
E/S,  
Sonar,  
Current  
indicator  
Menu setting  
See EXT KP INPUT on page 3-8.  
2-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5  
Transceiver Unit  
2.5.1  
Fabrication of connector 00-8016-038-313761HV (CN-B101)  
400  
Anticorrosive  
45  
40  
Shield  
Sheath  
Vinyl Sheath  
Armor  
Core  
Insulating Tape  
After exposing cores,  
wind shield around the armor.  
Fabrication of connector 00-8016-038-313761HV  
Shorten the unused wires appropriately and treat their ends with vinyl tape to  
prevent short circuit.  
Guide Pin A  
Guide Pin B  
Position No.  
Guide Pin B  
(Small)  
Guide Pin A  
(Large)  
Assembling 38P connector  
Positioning guide pins  
Guide pins of the connector identify the mating receptacle.  
They are;  
Guide pin A (Large): 1  
Guide pin B (Small): 1  
2-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5.2  
Fabrication of power cable type DPYCY-4 (TB-B101)  
Fabricate the cable DPYCY-4 as below for connection to the power unit.  
Cable DPYCY-4  
Armor  
Vinyl  
sheath  
Conductor  
2
S = 4 mm  
= 2.55 mm  
140  
(Power unit side: 200)  
35  
30  
M4 (YEL) x2  
FV5.5-4  
Anticorrosive  
sheath  
Vinyl sheath  
Armor  
Fabrication of cable type DPYCY-4  
2.5.3  
Hull control cable (10S2078)  
Connect the hull control cable (10S2078) to the CN-B102.  
Note: The same type of connector is fitted at each end, however the connector  
where the amount of sheath removed is greater should be connected to  
the transceiver unit.  
2-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.5.4  
Connection  
1. Open the transceiver unit cover.  
2. Plug the XH connectors at the end of signal cables (10S2140, 10S2141) into  
the proper receptacles in the transceiver unit, referring to the labels on the  
cables and numbers on the TRX board.  
3. Lead the cables into the transceiver unit appropriately. For clamping, lay the  
cables as shown in the figure “Cable location at metal clamp, top view” below.  
4. Unfasten the cable fixing strip after wiring the hull unit.  
Transceiver unit  
4
14  
16  
2
6
20  
8
10  
18  
12  
Clamps for  
lower slot  
Clumps for  
upper slot  
9
17  
13  
7
1
3
19  
15  
5
11  
Cable  
number  
Cable location at metal clamp, top view  
2-16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.6  
Power Supply Unit  
Connect the power cable DPYCY-4 or equivalent as below.  
For 220/230 VAC  
TB-D102 (AC IN)  
230V  
220V  
100V  
Ship's mains  
0V  
Transceiver unit  
Lay the armor  
of cable in the clamp.  
110/115V  
100V  
0V  
Lay the armor  
of cable in the clamp.  
TB-D101 (AC OUT)  
0V  
For 100/110/115 VAC  
Power unit connection  
2.7  
Cable for Extension Kit  
The standard length of the cable between the hull unit and transceiver unit is 5  
meters. If a longer cable is required use the extension kit. This kit provides a  
junction box and a 5 meters cable or 15 meters cable.  
2.7.1  
Junction box  
Connect the 10S2138 and 10S2139 of extension cables and transducer cables  
to the MTC1 and MTC2 in the junction box included with the cable extension kit,  
matching cable number with board location number.  
1. Open the junction box cover.  
2. Unfasten the metal clamp and fixing plates from the junction box.  
Junction box  
10S2139  
10S2138  
Signal cables from  
transceiver unit  
19 17 15 13 11  
9
7
5
3
1
2
4
6
8 10 12 14 16 18 20  
19 17 1513 11  
9 7 5 3 1  
2
4
6 8 10  
12 14 16 18 20  
10S2140 cable  
10S2141 cable  
Transducer cables  
Junction box, cover removed  
2-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Starting from the right side of the junction box, fix the cables by CSK clamp,  
pass them through cable clamps and connect XH connectors to the MTC  
board.  
Cable clamp  
Note: Capacitors not present  
on latest version of  
MTC board.  
CKS clamp  
Junction box, cover removed, front view  
Note: Capacitors not present  
on latest version of  
MTC board.  
Signal cables from  
transceiver unit  
Transducer cable  
(10S2140/10S2141)  
(10S2138/10S2139)  
Junction box, cover removed, front view  
4. Fasten the shield part of the cable with metal clamp.  
5. Fasten the fixing plates.  
2-18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.7.2  
Raise/Lower Control Box  
Connect power cable (3φ) and the transceiver unit cable (10S2078) as shown  
below.  
CN-C101  
Connect the transceiver  
cable (10S2078) to here.  
Cable TPYCY-4  
Sheath  
TB-C101  
Connect the power cable TPYCY-4  
(Japan Industrial Standard) or the  
Armor  
equivalent to this board.  
Vinyl  
sheath  
LED (Red)  
For detection of phase reversal on  
3 phase power cable  
Conductor  
S = 4 mm2  
= 2.55 mm  
Confirm LED after completing the installation. The LED lights (in red) if power  
connection is correct. If it is off, turn off power from the mains switchboard,  
check the cable connection and recheck the LED. The hull unit does not work if  
this connection is wrong.  
Normal phase: LED lights (in red).  
Phase reversal: LED does not light.  
Power cable (3φ)  
TPYCY-4  
Cable from  
transceiver unit  
10S2078  
Raise/lower control box, cover removed  
2-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
100  
25  
20  
M4(yellow) x 3  
FV5.5-4  
Vinyl  
sheath  
Sheath  
Armor  
(Clamp here by cable clamp.)  
Power cable fabrication  
2-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. ADJUSTMENT AND CHECK  
3.1  
Hull Unit Check  
Note: Before conducting this check (at the dry dock) transmission must be  
stopped.  
Default setting of TX transmission is OFF. Confirm as follows.  
1. Turn on the power, and then press the [MENU] key to show the main menu.  
MENU  
QUIT  
TX PULSE LENGTH-H : 9  
TX POWER-H  
TVG-NEAR-H  
TVG-MEDIUM-H  
TVG-FAR-H  
: 9  
: 0  
: 0  
: 0  
AGC-H  
: 0  
2ND AGC-H  
ECHO AVERAGE-H  
COLOR-H  
: 0  
: 0  
: COLOR 1  
COLOR RESPONSE-H : COLOR CURVE 3  
H-SCAN SETTING...  
V-SCAN SETTING...  
OTHERS...  
Main menu  
2. Use the trackball to select OTHERS and press the [MENU] key.  
MENU  
QUIT  
QUIT  
OTHERS  
ES1 SETTING...  
ES2 SETTING...  
ERASE MARKS...  
DISPLAY SETTING...  
FISH ALARM & AUDIO...  
PRESET, MEMORY CARD...  
INITIAL SETTING...  
OTHERS menu  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Select INITIAL SETTING and press the [MENU] key.  
CAUTION  
YES  
NO  
THIS ITEM IS DEFINED AS NON-  
CHANGEABLE ITEM, ARE YOU  
SURE TO CHANGE IT TO CHANGEABLE ?  
4. Select YES and press the [MENU] key.  
MENU  
OTHERS  
QUIT  
QUIT  
QUIT  
INITIAL SETTING  
MARK DISPLAY...  
MARK SIZE...  
DATA DISPLAY...  
CURRENT VEC & WIND...  
NET SONDE SETTING...  
NET SHOOT SETTING...  
TARGET LOCK...  
STABILIZATION...  
TEST...  
INITIALIZATION...  
INITIAL SETTING menu  
5. Select TEST and press the [MENU] key.  
MENU  
QUIT  
QUIT  
QUIT  
QUIT  
OTHERS  
INITIAL SETTING  
TEST  
BOARD TEST...  
PANEL TEST...  
TEST PATTERN...  
RX TEST...  
NOISE TEST...  
TX  
: ON  
TEST MENU  
6. Select TX and press the [MENU] key.  
7. Select OFF and press the [MENU] key.  
8. Select QUIT at the top of the menu screen and press the [MENU] key.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to check the hull unit  
1. Press the POWER (|) switch on the control unit (for the display unit) to turn on  
the equipment. Confirm that the lamps above the ON and  
switches light.  
Transducer switches  
2. Confirm that the 5V and UP lamps on the raise/lower control box are lit.  
3. Remove the cover of the raise/lower control box and use a multimeter to  
measure the following voltages:  
Terminal  
TB-C101  
Terminal No.  
(1) – (2), (6) –(7)  
Voltage  
220 VAC  
(2) – (3), (7) – (8) 220 VAC  
(1) – (3), (6) –(8) 220 VAC  
4. In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press  
the [DOWN] switch to confirm that the transducer lowers. Also, while the  
transducer is being lowered, check that the MD LED lights when the MD L.  
SW kicks. Note that the MD L. SW does not stop the transducer when the  
TEST/NORMAL switch is in the TEST position.  
TEST  
OFF  
NORMAL  
5V  
L.SW  
UP MD DN  
UP  
DOWN  
Control unit (for the hull unit)  
5. Press and release [DOWN] switch. Confirm that the transducer stops at the  
moment the switch is released.  
6. Press the [DOWN] switch again. Confirm that the transducer stops at the  
moment the lower limit switch kick.  
7. Confirm that the [UP] switch operators in a similar manner.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Check that LEDs on the panel of the raise/lower control box light as follows:  
a)UP, MD and DN LEDs light when corresponding limit switch is kicked.  
b)UP and DOWN LEDs light while UP and DOWN switches are pressed and  
extinguish when switches are released.  
9. Set the TEST/NORMAL switch to NORMAL.  
10. At the control unit for the display unit, press the  
(mid position) switch.  
Confirm that the lamp above the switch blinks while the transducer is being  
lowered, a short beep sounds when the mid limit switch kicks, and the lamp  
lights when the transducer is fully lowered.  
11. Press the  
switch. Confirm that the lamp above the switch blinks while  
the transducer is being lowered, a short beep sounds when the mid limit  
switch is kicked, and the lamp lights when the transducer is fully lowered.  
12. Press the  
switch. Confirm that the lamp above the switch blinks while  
the transducer is being raised, a short beep sounds when the mid limit switch  
is kicked, and the lamp lights when the transducer is fully raised.  
13. Press the OFF switch. Confirm that the transducer is completely retracted  
and then the power is turned off.  
14. With the transducer lowered, confirm that the transducer is raised when  
or OFF is pressed.  
3.2  
Heading Adjustment  
When the BOW mark on the flange of the hull unit cannot be directed toward  
ship’s bow adjust the heading so an echo which is dead ahead appears dead  
ahead on the display.  
1. Referring to the previous section, set the TX (transmission) to ON.  
2. Locate a target in the bow direction (buoy, for example) and display it on a  
near range. If the target appears at 12 o’clock the heading alignment is  
correct. If it does not, measure the error and go to step 2.  
If target's on-screen  
Buoy  
position is right of ship's  
bow for example, hull unit  
heading is skewed left.  
Heading adjustment  
3. After turning off the power, turn it again on the power while pressing and  
holding down the [MENU] key. Release the figure from the [MENU] key after  
the self- test screen appears. And then after picture appears, press the  
[MENU] key three times to open the SYSTEM menu.  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM MENU  
QUIT  
INTERFACE SETTING..  
EXT DATA SETTING..  
OWN SHIP MARK..  
TEST&INITIALIZATION..  
TRX SETTING 1..  
TRX SETTING 2..  
OTHERS..  
SYSTEM menu  
4. Use the trackball to select OTHERS and press the [MENU] key.  
5. Select HEADING ADJUST and press the [MENU] key.  
MENU  
QUIT  
QUIT  
OTHERS  
LANGUAGE  
: ENGLISH  
: 0  
QUIT  
CANCEL  
HEADING ADJUST  
ES2 SELECT  
: ES  
ES DRAFT OFFSET : 0.0 m  
EVENT KEY  
: EVENT  
AUTO TILT  
: WIDE  
: H/V INTERLOCK  
SELECT USER PROG  
TRACKBALL SPEED  
HULL UNIT STROKE  
: NORMAL  
: 1200mm  
OTHERS menu, HEADING ADJUST  
6. Select ! or " and press the [MENU] key to adjust the heading. Each  
pressing of the [MENU] key changes the setting in 1° steps. The setting  
range is -180° to 179°.  
7. Select QUIT to finish the adjustment and press the [MENU] key.  
8. Select QUIT at the top of the menu screen and press the [MENU] key to  
close all menus.  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3  
Configuring Own Ship Mark  
Set own ship’s dimensions and the location of the transducer to accurately  
display the own ship mark on the display.  
1. Press the [MENU] key to display the SYSTEM menu.  
SYSTEM MENU  
QUIT  
INTERFACE SETTING..  
EXT DATA SETTING..  
OWN SHIP MARK..  
TEST&INITIALIZATION..  
TRX SETTING 1..  
TRX SETTING 2..  
OTHERS..  
System menu  
2. Use the trackball to select OWN SHIP MARK and press the [MENU] key.  
MENU  
QUIT  
QUIT  
OWN SHIP MARK  
: 75m  
: 20m  
: 15m  
: 0.0m  
SHIP'S LENGTH  
SHIP'S WIDTH  
TD POSITION 1  
TD POSITION 2  
OWN SHIP MARK menu  
3. Use the trackball to select SHIP’S LENGTH.  
4. Press the [MENU] key to show the setting window.  
MENU  
QUIT  
QUIT  
OWN SHIP MARK  
QUIT  
CANCEL  
: 75m  
: 20m  
: 15m  
: 0.0m  
SHIP'S LENGTH  
SHIP'S WIDTH  
TD POSITION 1  
TD POSITION 2  
OWN SHIP MARK menu, setting window  
3-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Select ! or " and then press the [MENU] key several times to set the ship’s  
length (15 to 150 m).  
6. Select QUIT to finish the setting.  
7. Set the SHIP’S WIDTH (5 to 30 m), TD POSITION 1 (5 to 50 m) or TD  
POSITION 2 (-10.0 to 10.0 m) similarly.  
TD POSITION 1: Set the transducer’s distance from the bow.  
TD POSITION 2: Set the transducer’s distance from the keel. Select the [+] for  
starboard, [-] for port.  
8. Select QUIT at the top of the menu screen and press the [MENU] key to  
close all menus.  
TD POSITION 1  
SHIP'S LENGTH  
TD POSITION 2  
(Nagative for port)  
SHIP'S WIDTH  
Ship shape description  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 Other SYSTEM Menu Items  
This section shows you how to set up external equipment. Default settings are  
underlined.  
3.4.1  
INTERFACE SETTING menu  
MENU  
INTERFACE SETTING  
QUIT  
QUIT  
: 4800 bps  
: 4800 bps  
: 4800 bps  
NMEA 1 BAUD RATE  
NMEA 2 BAUD RATE  
CIF BAUD RATE  
AUX BAUD RATE  
EXT KP INPUT  
: 19200 bps  
: DISABLE  
: NEGATIVE  
EXT KP OUTPUT  
INTERFACE SETTING menu  
NMEA 1 BAUD RATE  
Set the transmission rate for the NMEA 1 port.  
(2400 bps, 4800 bps, 9600 bps, 19200 bps)  
NMEA 2 BAUD RATE  
Set the transmission rate for the NMEA 2 port.  
(2400 bps, 4800 bps, 9600 bps, 19200 bps)  
CIF BAUD RATE  
Set the transmission rate for the CIF port. (2400 bps, 4800 bps, 9600 bps, 19200  
bps) If the CS-120A is connected, select “2400 bps”.  
AUX BAUD RATE  
Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps,  
19200 bps)  
EXT KP INPUT  
Select whether the KP signal from external equipment is used or not, and set the  
edge polarity. (DISABLE, POSITIVE, NEGATIVE)  
Note: Set TX INTERVAL in H-SCAN SETTING menu to “0” for transmission with  
external kp signal.  
EXT KP OUTPUT  
Select the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE)  
3-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4.2  
EXT DATA SETTING menu  
MENU  
QUIT  
QUIT  
EXT DATA SETTING  
: CIF  
DATE&TIME  
HEADING  
: AD10S  
LOG PULSE  
: 200p/NM  
: NMEA  
SPEED&COURSE  
SPEED SENSOR  
LAT/LON  
: GPS/DR  
: NMEA  
: AUTO SEL.  
POSITIONING SENSOR  
: NMEA  
: NMEA  
WATER DEPTH  
WATER TEMP.  
: CIF  
: CIF  
WATER CURRENT  
WIND  
EXT DATA SETTING menu  
DATE &TIME  
Select input port of data and time data. (NONE, CIF, NMEA)  
HEADING  
Select input port of the heading data. (NONE, AD10S, CIF, NMEA)  
LOG PULSE  
Set the pulse rate per 1 nm for the distance pulse signal. (200 p/NM, 400 p/NM)  
SPEED & COURSE  
Select the input port for the ship’s speed and course data input. When selecting  
the LOG&HEADING, the heading data is used instead of the course data.  
(NONE, LOG&HEADING, CIF, NMEA)  
SPEED SENSOR  
Select the source for the speed and course data. This setting is ineffective when  
LOG&HEADING is selected as speed and course source. (NONE, GPS/DR,  
DOPPLER/DR)  
LAT/LON  
Select the input port for the ship’s position data. (NONE, CIF, NMEA)  
POSITIONING SENSOR  
Select the type of the navigator. When selecting AUTO SEL., the priority is  
GPS/DR>LORAN-C. (LORAN-C, GPS/DR, AUTO SEL.)  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WATER DEPTH  
Select the input port for the depth data. (NONE, CIF, NMEA)  
WATERTEMP.  
Select the input port for the water temperature data. (NONE, CIF, NMEA)  
WATER CURRENT  
Select the input port for the water current data. (NONE, CIF, NMEA)  
WIND  
Select the format for the wind data. (NONE, CIF, NMEA)  
NMEA 0183 Data  
Input  
Position (L/L)  
Heading  
Course  
GGA, GLL, RMA, RMC  
HCC, HCD, HDG, HDM, HDT  
VTG  
Speed  
Current  
Depth  
Temperature  
Wind  
VBW, VHW  
CUR, VDR  
DBS, DBT, DPT  
MTW  
MWV  
Date Time  
ZDA  
Output  
Position  
TLL  
3.4.3  
OTHERS menu  
MENU  
QUIT  
QUIT  
OTHERS  
LANGUAGE  
: English  
HEADING ADJUST  
ES2 SELECT  
: 0  
: ES  
ES DRAFT OFFSET : 0.0 m  
EVENT KEY  
: EVENT  
AUTO TILT  
: WIDE  
: H/V INTERLOCK  
: NORMAL  
: 1200mm  
SELECT USER PROG  
TRACKBALL SPEED  
HULL UNIT STROKE  
OTHERS menu  
3-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LANGUAGE  
Select the language. (JAPANESE, ENGLISH)  
HEADING ADJUST  
See “3.2 Heading Adjustment”.  
ES2 SELECT  
Select the equipment connected to the ES2 port among echosounder and net  
recorder. (ES, NET REC)  
ES DRAFT OFFSET  
When connecting echosounder, set the ship’s draft line to use depth from draft  
rather than depth from transducer. (0.0 m to 10.0 m, 0.1 m steps)  
EVENT KEY  
Select the key for entering own ship’s position, EVENT or SHOOT. When  
selecting SHOOT, the shoot function is not available. (EVENT, SHOOT)  
AUTO TILT  
Select the range for the auto tilt, WIDE (±2 to 10°, ±4 to 16°, ±6 to 20°) or  
NARROW (±1 to 4°, ±2 to 6°, ±3 to 8°). (WIDE, NARROW)  
SELECT USER PROG  
Select whether to program horizontal and vertical displays together or  
individually, by the USER PROG control. H/V INTERLOCK, the default setting,  
commonly applies control settings to the horizontal and vertical displays. H/V  
INDVIDUAL enables individual adjustment.  
TRACKBALL SPEED  
Select the speed of trackball movement (inside menu window only). (SLOW,  
NORMAL, FAST)  
HULL UNIT STROKE  
Select the stroke length of the hull unit. (1200 mm, 1600 mm).  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.5  
CONE Board Setting in the Processor Unit  
Adjust the potentiometers on the CONE Board in the processor unit, referring to  
the table shown below.  
Location No.  
R118  
Name  
Resistance value Function  
Adjustment  
ALARM  
10 k  
Adjusting the volume of  
CW: Large  
audio alarm.  
Adjusting E/S2 signal  
offset.  
CCW: Small  
R119  
R167  
R168  
R209  
ES2_OFF  
1 kΩ  
CW: Noise decrease  
CCW: Noise increase  
ES_2GAIN 10 kΩ  
ES1_OFF 1 kΩ  
ES1_GAIN 10 kΩ  
Adjusting E/S2 signal gain. CW: Gain increase  
CCW: Gain decrease  
Adjust E/S1 signal offset.  
CW: Noise decrease  
CCW: Noise increase  
CW: Gain increase  
CCW: Gain decrease  
Adjust E/S1 signal gain.  
3.5.1  
Adjustment of signal level (echo sounder connected)  
Adjusts the output level of the echo sounder on the CONE Board as below.  
1. Select an echo sounder display (ES1 or ES2) from the menu.  
2. For ES 1, adjust R168 to suppress noise, and then adjust R209 so that the  
picture condition is similar to that of connected echo sounder connected to  
the FSV-24.  
3. For E/S 2, adjust R119 to suppress noise, and then adjust R167 so that the  
picture condition is similar to that of echo sounder connected to the FSV-24.  
3.5.2  
Adjusting the volume of audio alarm  
The audio alarm volume cannot be adjusted from the control unit. If necessary,  
adjust R118 on the CONE Board to choose desired volume.  
3-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6  
DIP Switch Setting  
Processor unit, inside view  
3.6.1  
CIF2/NMEA2 connector interface selection  
The signal format of the CIF2/NMEA2 port at the back of the processor unit can  
be set for CIF or NMEA by DIP switch S2-8 on the IFES Board (10P6903). The  
default format is OFF (CIF).  
DIP switch setting  
S2-#8: ON  
Format  
NMEA  
CIF  
S2-#8: OFF  
S2  
IFES Board (10P6903)  
3-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6.2  
Selecting the Net Sonde information  
The net depth information from the Net Sonde can be entered from the FNZ port  
or CIF port. Depending on the input port, select the DIP switch setting as follows.  
The default setting is FNZ.  
Input port  
DIP switch S3 - #1  
FNZ(default)  
CIF1 or NMEA2/CIF2  
OFF  
ON  
S3  
DCON Board (10P6900 or 10P6900S)  
Note1: When the NMEA2/CIF2 port is used, the DIP switch S2-#8 on the IFES  
board should be OFF. See page 3-13.  
Note2: Do not change the setting of S3-#4 (default: OFF). The hull unit may be  
damaged if the setting is changed.  
3.6.3  
Selecting echosounder signal  
There are two kinds of echosounder signals, AC signal and DC signal.  
Depending on the signal, select the jumper setting at J496 and J497 on the  
CONE board as follows. The default setting is AC. See page 3-13 for parts  
location.  
Input port  
ES1  
Jumper  
J497  
ES2/NET  
J496  
Note: SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output  
port are provided for FURUNO echosounder. Therefore, when using  
SIGOUT terminal, it is not necessary to change jumper setting.  
3-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.7  
TestingTX/RX independently at hull unit  
To check the Tx/Rx function of the hull unit independently, follow the steps  
below.  
Note: This test should not be done at the dry dock. The transducer will be  
damaged.  
1. Turn ON DIP switch S3#1 on the TRCPU Board (10P6926) in the transceiver  
unit.  
2. Turn the TEST/NORMAL switch in the control unit of the hull unit to TEST.  
3. Turn ON the maintenance switch in the transceiver unit.  
4. Power on the transceiver unit, and then press the [DOWN] switch in the  
control unit for the hull unit to lower the transducer to the mid or fully lower  
position.  
5. Confirm the MID or DN LED for the transducer position.  
6. When the transducer reaches to mid or fully lower position, the transducer  
starts the transmission automatically with low power. Check the transmission  
channel.  
7. Press the [UP] switch in the control unit for the hull unit to retract the  
transducer. Transmission stops.  
8. Turn OFF the maintenance switch in the transceiver unit.  
9. Turn the TEST/NORMAL switch in the control unit of hull unit to NORMAL.  
10.Turn OFF DIP switch S3#1 on the TRCPU Board in the transceiver unit.  
S3  
TRCPU Board (10P6926)  
3-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page is intentionally left blank.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. CONNECTING THE EXTERNAL  
INTERFACE CS-120A  
When upgrading from the CSH-20 series sonar, the External Interface CS-120A  
can be used. Connect between the processor unit and the CS-120A as shown  
below. However, we recommend to connect external device to processor unit,  
instead of using the CS-120A, to avoid signal delay.  
The following power supply kit (option) is required to install on the processor  
unit.  
Name: Power Supply Kit Type: FSV-2403 Code No.: 000-067-013  
Name  
Power supply pcb  
Spacer  
Protection sheet  
Screw  
Type  
Code No.  
Q’ty Remarks  
LEA50F-24-XFND 000-143-913  
1
4
1
4
1
SQ-22  
000-159-305-10  
100-290-712  
000-163-190-10  
000-160-184-10  
10-071-3508  
M3x8 C2700W  
NJC-203-PM  
Connector (NJC)  
1. Remover the front cover of the processor unit.  
Screw  
M4x8 7 pcs.  
FURUNO  
W
AR  
N
IN  
G
Details  
omitted  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Remove two upset screws, detach the plugs J503, J502, J501, J504, J506  
and J507, thus pull out the power block.  
Protection sheet  
VH4P  
Spacer  
Detach J503, J502,  
J501, J504 and  
J506.  
IFES  
SCAN  
SCAN2  
DU  
Power supply  
pcb  
AL  
DCON  
VH5P  
Power Block  
Upset screws  
M5x25 SUS 2 pcs.  
Pin  
Hole  
Detach J507.  
3. Fix the power supply pcb (supplied) to the power block with spacers  
(supplied).  
4. Connect two VH connectors (provided on the power block) to the power  
supply pcb.  
5. Put protection sheet (supplied) on the power supply pcb and fasten it with  
four screws.  
6. Reattach the power block.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Connect between the processor unit and CS-120A as follows.  
Processor Unit  
POWER FOR CS-120A port  
NJC-203-PM  
YEL BRN  
CS-120A  
J201  
+24V_H  
+24V_C  
GND  
1
2
3
24V  
0V  
GND  
L
E
PP  
ORG BRN  
PPL BRN  
CIF1 or NMEA2/CIF2  
port  
CIF_TXD_H  
CIF_TXD_C  
CIF_RXD_H  
CIF_RXD_C  
SHIELD  
1
2
3
4
TD-H  
TD-C  
NN  
MM  
JJ  
KK  
BB  
EE  
DD  
Z
RD-H  
RD-C  
GND  
DSR-C  
DSR-H  
DTR-H  
10  
37-cores cable  
10S1258  
Note: Echosounder should be connected to the processor unit directly.  
8. Set the DIP switch as follows.  
Input port  
CIF1  
DIP switch setting  
S3-#2: ON  
NMEA 2/CIF 2  
S3-#3: ON  
S3  
DCON Board (10P6900 or 10P6900S)  
Note:Do not change the setting of S3-#4 (default: OFF). The hull unit may be  
damaged if the setting is changed.  
Note:If the CIF is select, baud rate should be changed to 2400 bps. See page  
3-9 for detail.  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Check List Ship Name  
Date  
/
/
Location  
SCANNING  
SONAR  
S/N  
TYPE FSV-24  
RESULT  
Monitor unit (FSV-2400)  
Control unit (FSV-2401)  
Processor unit (FSV-2402)  
Transceiver unit (FSV-241E)  
Power supply unit (FSV-242)  
Hull unit (FSV-243E/244E )  
Options  
CS-120A  
VI-1100A  
CS-170  
FSV-2451(5m),FSV2452(15m)  
Reference  
Frequency  
24KHz  
Transducer location  
Note:  
NO CHECK ITEMS  
CONTENT  
RESULT  
Good/No Good  
DATA  
1
Unit installation All units are installed according to installation  
manual.  
2
Grounding  
Copper plate should be connected for the  
following units.  
Good/No Good Sheet 1  
1.Power supply unit  
2.Transceiver unit  
3.Junction box(Option)  
IV-8sq is connected for the following units.  
1.Raise/lower box  
2.Processor unit  
3.Monitor unit  
3
Connection  
Check the connection between each unit.  
1.Transducer-Transceiver unit  
2.Transceiver unit-Processor unit  
3.Processor unit-Monitor unit  
4.Monitor unit-Control unit  
5.Processor unit- Other equipments  
6.Ship’s mains-Power supply unit  
7.Ship’s mains-Hull unit  
Good/No Good Sheet 1  
8.Ship’s mains-Processor unit  
4
Power Supply  
(Ship’s mains)  
Check ship’s mains voltage for following units. Good/No Good Sheet 1  
1.Power supply unit  
2.Raise/lower motor line  
Check whether led of phase detector is light or  
not.  
The 3 phase line must be changed if led is light.  
3.Processor unit  
5
6
Output power  
Test  
Check output power and +B voltage.  
Check the following tests.  
Good/No Good Fig1  
Good/No Good Sheet2  
Board test/Panel test/RX test/Channel  
test1/Channel test2/Noise test  
Check the user program setting.  
Installation  
manual  
Sheet3  
7
8
Setting  
Operation check Check pictures after turning on the power.  
Good/No Good  
AP-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DATA SHEET 1  
General check  
CK; DT: digital tester AT: analog tester OS:oscilloscope WC:watch  
Check item  
Content  
Check point  
CK  
WC Refer to  
installation  
Standard  
Judge  
Connection All connection  
1.Transducer-transceiver unit  
should be checked 2.Processor unit-Transceiver unit  
refering to the  
interconnection  
diagram.  
3.Processor unit-Control unit  
4.Processor unit-Others equipment  
5.Ship’s mains-Power supply  
unit-Processor unit  
manual  
Grounding  
All grounding  
1.Monitor unit  
WC Refer to  
should be checked 2.Processor unit  
installation  
manual  
by installation  
manual.  
3.Transceiver unit  
4.Power supply unit  
5.Junction box(Option)  
Power Supply(ship’s main voltage)  
Unit  
Check point  
CK  
Standard  
AC100/110/115/220/230V±10%  
Result Judge  
Processor unit  
CN-A110  
DT  
Transceiver unit TB-B101 #1---#2 DT AC90V to AC115V  
Power supply unit TB-D102 DT  
Hull unit TB-C101 DT AC220V  
AC100/110/115/220/230V±10%  
Note that: The input voltage may be dropped while the capacitors are being charged before  
transmission. For accurate data, please check the voltages during TX on and off as well when you  
check the input voltage of a transceiver unit.  
The input voltage monitoring circuit in transceiver unit detects low voltage when AC 100V power  
source drops to 85V. On the other hand, if the input voltage is 120 to 130V, the over voltage flag is  
set and an alarm is displayed to monitor.  
AP-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DATA SHEET 2  
DISPALY UNIT (FSV-2400 )  
Check item  
Software  
version  
Contents  
Check software version on Self-check  
the each board display  
DCON 1050714***  
DUAL 1050703***  
Check point  
CK  
WC  
Standard  
Result Judge  
IFES  
KEY  
1050711***  
1050685***  
TRCPU 1050717***  
TRX  
1050665***  
to 1050684***  
TRANSCEIVER UNIT(FSV-241)  
Check item  
Contents  
Check point  
Test points on  
CK Meter reading Result Judge  
OS See fig 1  
TX output  
Check transmission output  
power voltage at following the TRX boards.  
1st layer  
conditions:  
Range: 1000m  
TX setting: 9-9-9  
2nd layer  
3rd layer  
Tilt:  
0
4th layer  
Stabilize.: OFF  
TX weight: all 1  
Measuring point  
5th layer  
6th layer  
7th layer  
TP108-137  
8th layer  
Measure peak-to-peak  
voltage at 5ms from the  
leading edge of the  
transmission pulse.  
9th layer  
10th layer  
11th layer  
12th layer  
13th layer  
14th layer  
15th layer  
16th layer  
17th layer  
18th layer  
19th layer  
20th layer  
There are 15 channels of  
TX_P/N on each TRX  
board. (Totally 600ch)  
Fig 1 TX output power and B voltage  
Normally, the output power voltage should read 1400Vp-p. However, it varies within ±15% because of  
transducer impedance. B voltage is normally 120V at each transmission.  
1400Vp-p  
5ms  
AP-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DATA SHEET 3  
User menu  
H-scan setting  
P1  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
Range  
Gain  
Tilt  
Tinterval  
Pulse length  
Tx output  
TVG near  
TVG middle  
TVG far  
NL  
AGC  
2AGC  
Echo average  
IR  
Color  
Color curve  
Display gain  
Delete color  
Far TVG curve  
Beamwidth-H  
Write by color response curve sheet.  
V-scan setting  
Range  
P1  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
Gain  
Tinterval  
Pulse length  
TVG Near  
TVG middle  
TVG far  
NL  
AGC  
Echo average  
IR  
Color  
Color curve  
Display gain  
Delete color  
Far TVG curve  
Beamwidth-V  
Write by color response curve sheet.  
AP-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TRX setting1  
TRX setting1  
TX weight  
P1  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
RX weight-H  
RX weight-V  
Auto filter  
Bandwidth  
COR start distance  
COR window length  
Gain at COR  
TRX setting2  
TRX setting2  
Near TVG curve-H  
Near TVG curve-V  
Near gain-H  
P1  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
Near gain-V  
Pre TVG-H  
Pre TVG-V  
Post TVG-H  
Post TVG-V  
Absorption coeff.  
Color response curve sheet (H)  
P1  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
Color response curve  
Color response curve sheet (V)  
P1  
P2  
P3  
P4  
P5  
P6  
P7  
P8  
P9  
P10  
Color response curve  
AP-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-1  
CODE NO.  
TYPE  
006-921-230-00  
CP10-04501  
10CO-X-9401 -6  
1/1  
工事材料表  
INSTALLATION MATERIALS  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
DESCRIPTIONS  
表示部用  
コネクタ(8016)  
FOR MONITOR UNIT  
008016-038-313761HVF  
CODE  
1
2
3
4
5
1
CONNECTOR(8016)  
NO.  
000-159-017-10  
60-8017-0313-00339F+  
60-8017-0313-00-339  
表示部用  
FOR MONITOR UNIT  
コンタクト ピン(8017)  
2
5
1
1
CONTACT PIN (8017)  
000-159-417-10  
000-519-542-00  
CODE  
NO.  
BNC-P-2.5  
BNC-P-2.5  
表示部用  
FOR MONITOR UNIT  
コネクタ(BNC)  
CONNECTOR(BNC)  
000-165-521-10  
000-144-384-00  
CODE  
NO.  
表示部用  
FOR MONITOR UNIT  
コネクタ(XM2)  
XM2A-2501  
CODE  
CONNECTOR(XM2)  
NO.  
000-154-172-10  
表示部用  
FOR MONITOR UNIT  
コネクタフード(XM2)  
CONNECTOR HOOD  
XM2S-2513  
CODE  
NO.  
000-154-183-10  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9401  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-2  
CODE NO.  
TYPE  
006-921-240-00  
CP10-04502  
10CO-X-9402 -5  
1/1  
工事材料表  
INSTALLATION MATERIALS  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
DESCRIPTIONS  
制御部用  
コネクタ(8016)  
FOR PROCESSOR UNIT  
008016-038-313761HVF  
1
2
3
4
1
CONNECTOR(8016)  
CODE NO.  
000-159-017-10  
60-8017-0313-00339F+  
制御部用  
FOR PROCESSOR UNIT  
コンタクト ピン(8017)  
60-8017-0313-00-339  
2
6
1
CONTACT PIN (8017)  
000-159-417-10  
000-519-542-00  
CODE NO.  
M6X25 SUS304  
制御部用  
FOR PROCESSOR UNIT  
六角スリワリ セムスB  
M6X25 SUS304  
HEX.BOLT  
(SLOTTED,WASHER HEAD)  
000-162-949-10  
CODE NO.  
000-802-771-00  
*ROHS*  
NCS-253-P  
NCS-253-P  
制御部用  
FOR PROCESSOR UNIT  
コネクタ(NCS)  
CONNECTOR(NCS)  
000-160-153-10  
000-506-503-10  
CODE NO.  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.  
QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9402  
FURUNO ELECTRIC CO .,LTD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-3  
CODE NO.  
TYPE  
006-921-250-00  
CP10-04503  
10CO-X-9403 -4  
1/1  
工事材料表  
INSTALLATION MATERIALS  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
DESCRIPTIONS  
008016-038-313761HVF  
送受信装置用  
FOR TRANSCEIVER UNIT  
コネクタ(8016)  
00-8016-038-313761HV  
1
2
3
4
1
CONNECTOR(8016)  
000-159-017-10  
000-127-234-00  
CODE NO.  
60-8017-0313-00339F+  
送受信装置用  
FOR TRANSCEIVER UNIT  
コンタクト ピン(8017)  
60-8017-0313-00-339  
2
2
1
CONTACT PIN (8017)  
000-159-417-10  
000-519-542-00  
CODE NO.  
送受信装置用  
FOR TRANSCEIVER UNIT  
圧着端子  
FV5.5-4  
CRIMP-ON LUG  
CODE NO.  
000-538-123-00  
送受信装置用  
FOR TRANSCEIVER UNIT  
アース板  
WEA-1004-0  
CODE NO.  
COPPER STRAP  
500-310-040-00  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.  
QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9403  
FURUNO ELECTRIC CO .,LTD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-4  
CODE NO.  
TYPE  
10CO-X-9412 -1  
1/1  
工事材料表  
FSV-247/248  
INSTALLATION MATERIALS  
数量  
Q'TY  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
略  図  
OUTLINE  
用途/備考  
REMARKS  
圧着端子  
FV5.5-4  
CODE NO.  
1
2
3
4
5
6
7
3
1
CRIMP-ON LUG  
000-538-123-00  
Oリング  
JISB2401-1A-V585  
CODE NO.  
O-RING  
000-851-421-00  
バネ座金  
M20 SUS304  
CODE NO.  
19  
38  
33  
14  
1
SPRING WASHER  
000-864-270-00  
六角ナット 1種  
HEX.NUT  
M20 SUS304  
CODE NO.  
000-863-116-00  
ミガキ平座金  
M20 SUS304  
CODE NO.  
FLAT WASHER  
000-864-136-00  
六角ボルト  
HEX.BOLT  
M20X120 SUS304  
CODE NO.  
000-806-235-00  
アース板  
WEA-1004-0  
CODE NO.  
COPPER STRAP  
500-310-040-00  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.  
QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9412  
FURUNO ELECTRIC CO .,LTD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-6  
CODE NO.  
TYPE  
006-921-290-00  
CP10-04506  
10CO-X-9406 -3  
1/1  
工事材料表  
INSTALLATION MATERIALS  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
コネクタ(SRCN)  
SRCN6A13-5P  
1
2
1
CONNECTOR(SRCN)  
CODE  
NO.  
000-160-726-10  
コネクタ(SRCN)  
SRCN6A16-10P  
CODE  
1
CONNECTOR(SRCN)  
NO.  
000-160-728-10  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9406  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-6A  
CODE NO.  
TYPE  
006-934-240-00  
CP10-04801  
10CO-X-9410 -1  
1/1  
工事材料表  
INSTALLATION MATERIALS  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
コネクタ(SRCN)  
SRCN6A13-3P  
1
2
3
4
5
1
CONNECTOR(SRCN)  
CODE  
NO.  
000-508-660-00  
コネクタ(SRCN)  
SRCN6A16-10P  
CODE  
1
1
1
1
CONNECTOR(SRCN)  
NO.  
000-160-728-10  
コネクタ(SRCN)  
SRCN6A16-7P  
CODE  
CONNECTOR(SRCN)  
NO.  
000-160-730-10  
コネクタ(SRCN)  
SRCN6A21-10P  
CODE  
CONNECTOR(SRCN)  
NO.  
000-160-735-10  
コネクタ(SRCN)  
SRCN6A21-10S  
CODE  
CONNECTOR(SRCN)  
NO.  
000-160-736-10  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9410  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-7  
CODE NO.  
TYPE  
10CO-X-9408 -3  
1/1  
工事材料表  
FSV-24/24S  
INSTALLATION MATERIALS  
数量  
Q'TY  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
10S2078  
略  図  
OUTLINE  
用途/備考  
REMARKS  
送受信装置-上下装置  
ケーブル(組品)  
CABLE ASSY.  
10S2078  
1
1
000-160-862-10  
000-144-389-00  
CODE NO.  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT.  
QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
C1318-M10-C  
FURUNO ELECTRIC CO .,LTD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-8  
CODE NO.  
TYPE  
006-922-390-00  
FP10-02201  
10CO-X-9501 -2  
1/1  
付属品表  
ACCESSORIES  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
操作部用  
KB直付け金具  
FOR CONTROLL UNIT  
03-144-1691-1  
1
2
3
4
5
6
7
8
9
1
KB FIXNG PLATE  
CODE  
NO.  
100-263-941-00  
操作部用  
FOR CONTROLL UNIT  
ダストカバーKB  
03-144-1693-0  
CODE  
1
1
2
2
2
2
2
4
DUST COVER KB  
NO.  
100-271-760-00  
操作部用  
FOR CONTROLL UNIT  
コネクタシール  
05-040-0108-0  
CODE  
DUMMY FILM  
NO.  
100-117-120-00  
操作部用  
FOR CONTROLL UNIT  
六角ナット 1種  
HEX. NUT  
M4  
C2700W MBNI2  
CODE  
NO.  
000-863-206-00  
操作部用  
FOR CONTROLL UNIT  
バネ座金  
M4 C5191W MBNI2  
CODE  
SPRING WASHER  
NO.  
000-864-206-00  
操作部用  
FOR CONTROLL UNIT  
ミガキ平座金  
M4 C2600P MBNI2  
CODE  
FLAT WASHER  
NO.  
000-864-106-00  
操作部用  
FOR CONTROLL UNIT  
+サラ小ネジ  
M4X12 C2700W MBNI2  
CODE  
OVAL HEAD SCREW  
NO.  
000-163-309-10  
操作部用  
FOR CONTROLL UNIT  
+アプセットUIセムスB  
M5X10 SUS304  
CODE  
+HEX.BOLT  
(WASHER HEAD)  
NO.  
000-163-757-10  
SJ-5003 クロ  
SJ-5003 クロ  
操作部用  
FOR CONTROLL UNIT  
ゴム足  
RUBBER FEET  
000-165-669-10  
000-801-787-00  
CODE  
NO.  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
10CO-X-9501  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-11  
006-921-350-00  
SP10-02602  
CODE NO.  
TYPE  
1/1  
10CO-X-9302 -4  
BOX NO.  
P
SETS PER  
VESSEL  
SHIP NO.  
SPARE PARTS LIST FOR  
U S E  
QUANTITY  
WORKING  
REMARKS/CODE NO.  
DWG. NO.  
ITEM  
NO.  
OR  
NAME OF  
PART  
OUTLINE  
TYPE NO.  
PER  
SET  
PER  
VES  
SPARE  
コネクタ(組品)  
100  
10  
2
1
CONNECTOR  
ASSY.  
1
2
3
4
5
XH20S-100  
000-144-382-00  
送受信装置>B電圧電源部  
ヒューズ  
FUSE  
FOR TORNSCEIVER/RECEVER  
10  
2
FGBO 250V 5A  
PBF  
000-155-840-10  
送受信装置>DC電源部用  
ヒュ-ズ  
FUSE  
FOR TORNSCEIVER/RECEVER  
FGMB 125V 10A  
PBF  
000-157-470-10  
送受信装置用  
ヒューズ  
FUSE  
FOR TORNSCEIVER/RECEVER  
2
2
FGB1 250V 30A  
000-155-870-10  
送受信装置用  
ヒューズ  
FOR TORNSCEIVER/RECEVER  
20  
10  
FUSE GLASS  
TUBE TYPE  
FGBO 250V 15A  
PBF  
000-157-874-10  
1/1  
MFR'S NAME  
DWG NO.  
FURUNO ELECTRIC CO.,LTD.  
10CO-X-9302  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変  
わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE  
UPPER PRODUCT. QUALITY IS THE SAME.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-12  
1/1  
006-921-340  
SP10-02601  
10CO-X-9301 -1  
BOX NO.  
CODE NO.  
TYPE  
P
SETS PER  
VESSEL  
SHIP NO.  
SPARE PARTS LIST FOR  
U S E  
QUANTITY  
WORKING  
REMARKS/CODE NO.  
DWG. NO.  
ITEM  
NO.  
OR  
NAME OF  
PART  
OUTLINE  
TYPE NO.  
PER  
SET  
PER  
VES  
SPARE  
FGB0 250V  
10A PBF  
指示装置>制御部用  
FOR DISPLAY UNIT  
ヒューズ  
FUSE  
2
2
1
000-155-839-10  
000-549-067-00  
FGBO 10A  
AC250V  
1/1  
MFR'S NAME  
DWG NO.  
FURUNO ELECTRIC CO.,LTD.  
C1318-P03-B  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は  
変わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE  
UPPER PRODUCT. QUALITY IS THE SAME.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-13  
1/1  
006-921-360  
SP10-02603  
10CO-X-9303 -1  
BOX NO.  
CODE NO.  
TYPE  
P
SETS PER  
VESSEL  
SHIP NO.  
SPARE PARTS LIST FOR  
U S E  
QUANTITY  
WORKING  
REMARKS/CODE NO.  
DWG. NO.  
ITEM  
NO.  
OR  
NAME OF  
PART  
OUTLINE  
TYPE NO.  
PER  
SET  
PER  
VES  
SPARE  
上下装置(制御器用)  
FOR HALL UNIT  
FGMB 250V 2A  
PBF  
ヒューズ  
FUSE  
1
1
1
000-157-497-10  
000-122-000-00  
FGMB 2A 250V  
1/1  
MFR'S NAME  
DWG NO.  
FURUNO ELECTRIC CO.,LTD.  
C1318-P04-B  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変  
わりません。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE  
UPPER PRODUCT. QUALITY IS THE SAME.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D - 7  
Jan. 28, '03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D - 8  
Jan. 28 '03  
Jan. 28, '03  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-9  
T akahashi T  
.
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S - 1  
1
2
3
4
5
6
送受信装置 FSV-241E  
TRANSCEIVER UNIT  
制御部 FSV-2402/2402S  
表示部  
FSV-2400  
上下装置  
HULL UNIT  
10S2145,20m *3  
10S2144,10m *3  
10S2078,5m  
(VV-SBCJ-0.3x14P,φ11.4)  
ミドリ GRN  
操作部 FSV-2401  
CONTROL UNIT  
CN-A201  
XHP-15  
J1  
PROCESSOR UNIT  
CN-A101  
MONITOR UNIT  
CN-A303  
CN-C101  
J1 *6 *2  
A
CN-A103/108  
10S2075,30m,φ25  
10S2074,10m,φ25  
チャ 17 BRN  
CN-A301  
CN-B102  
MSRXD-H  
MSRXD-C  
MSTXD-H  
MSTXD-C  
UPLSW-H  
UPLSW-C  
DEMGUP-H  
CN-B101  
*2 *6  
*6 J445  
*2  
J1  
A
B
C
D
E
F
H
J2 *6  
A
10S1258-1,φ18,MAX.100m  
アカ 11 RED  
*6 *2  
10S2076,5m  
クロ  
J411/421  
A
J511  
J531  
*6 *2  
FSV-247  
FSV-248  
*6  
A
B
C
D
E
F
H
TRXRXD-H  
TRXRXD-C  
TRXTXD-H  
TRXTXD-C  
SIG_D0-H  
SIG_D0-C  
DEMGUP-H  
CN1RXD-H  
CN1RXD-H  
A
B
C
D
E
F
J
K
L
4 YEL  
4 BLK  
3
4
1
2
5
6
7
8
9
10  
CN1RXD-H  
CN1RXD-C  
CN1TXD-H  
CN1TXD-C  
CN1TXA-H  
CN1TXA-C  
CN1TXB-H  
CN1TXB-C  
CN1TYA-H  
CN1TYA-C  
A
B
C
D
E
F
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
MM  
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
アカ  
アオ  
クロ  
RED  
BLU  
BLK  
B
C
D
E
F
H
チャ 11 BRN  
クロ 10 BLK  
シロ 10 WHT  
ダイ 12 ORG  
チャ 12 BRN  
アカ 19 RED  
ダイ 19 ORG  
B
C
D
E
F
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
MM  
シロ 17 WHT  
ムラ 18 PPL  
シロ 18 WHT  
ミドリ 19 GRN  
アカ 19 RED  
CN1RXD-C  
CN1TXD-H  
CN1TXD-C  
CN1TXA-H  
CN1TXA-C  
NC  
CN1TXB-H  
CN1TXB-C  
CN1TYA-H  
CN1TYA-C  
CN1TYB-H  
CN1TYB-C  
CN1PON-H  
CN1PON-C  
CN1POF-H  
CN1POF-C  
CN1AUDV1  
NC  
CN1RXD-C  
CN1TXD-H  
CN1TXD-C  
CN1TXA-H  
CN1TXA-C  
CN1TXB-H  
CN1TXB-C  
CN1TYA-H  
CN1TYA-C  
CN1TYB-H  
CN1TYB-C  
GND  
ミドリ 3 GRN  
クロ  
アオ  
クロ  
チャ  
クロ  
ムラ  
クロ  
アカ  
シロ  
3 BLK  
5 BLU  
5 BLK  
6 BRN  
6 BLK  
7 PPL  
7 BLK  
8 RED  
8 WHT  
ムラサキ PPL  
A
B
C
D
シロ  
チャ  
クロ  
チャ  
シロ  
アオ  
シロ  
WHT  
BRN  
BLK  
BRN  
WHT  
BLU  
WHT  
YEL  
BLK  
WHT  
BLK  
TT  
LL DEMGUP-C  
LL  
J
LL DEMGUP-C  
20 YEL  
P
P
P
P
P
J
K
N
P
R
S
T
U
V
X
W
Y
Z
MDLSW-H  
MDLSW-C  
DNLSW-H  
DNLSW-C  
DNCMD-H  
DNCMD-C  
UPCMD-H  
UPCMD-C  
DUPLSW-H  
DUPLSW-C  
TSFLG-H  
TSFLG-C  
MSROLL  
クロ  
ハイ  
9 BLK  
9 GRY  
13 YEL  
J
K
L
M
N
P
R
S
T
U
V
X
W
Y
Z
SIG_D1-H  
SIG_D1-C  
SIG_D2-H  
SIG_D2-C  
SIG_D3-H  
SIG_D3-C  
SIG_D4-H  
SIG_D4-C  
SIG_D5-H  
SIG_D5-C  
DUPLSW-H  
DUPLSW-C  
AUDIO-H  
AUDIO-C  
+12V  
アカ 20 RED  
アオ 21 BLU  
アカ 21 RED  
チャ 22 BRN  
アカ 22 RED  
ムラ 23 PPL  
アカ 23 RED  
K
L
M
N
P
R
S
T
U
V
X
W
Y
Z
M
N
TB-C101  
U
V
W
1
11 CN1TYB-H  
12 CN1TYB-C  
2
3
4
5
6
7
8
チャ 13 BRN  
P
JJ  
GND KK  
GND LL  
13  
クロ  
ムラ  
ダイ  
クロ  
クロ  
アカ  
クロ  
チャ  
クロ  
8 BLK  
8 PPL  
4 ORG  
4 BLK  
3 BLK  
3 RED  
5 YEL  
5 BLK  
2 BRN  
2 BLK  
ミドリ 14 GRN  
アカ 14 RED  
GND  
クロ  
シロ  
クロ  
14 GND  
15 GND  
24 YEL  
ムラサキ PPL  
ミドリ 24 GRN  
ミドリ 25 GRN  
CN-A202  
J2  
CN1PON-H  
XHP-14  
1
R
S
T
U
V
X
Z
W
Y
クロ  
アカ  
シロ  
BLK  
RED  
WHT  
CN1PON-H  
シロ  
クロ  
アカ  
クロ  
シロ  
1 WHT  
1 BLK  
2 RED  
2 BLK  
9 WHT  
P
P
P
P
P
P
P
P
P
CN1PON-C  
CN1POF-H  
CN1POF-C  
CN1AUDV1  
CN1AUDV2  
CV1AUDV3  
CN1BRLV1  
CN1BRLV2  
CN1BRLV3  
+12V  
2
3
4
5
6
7
8
9
CN1PON-C  
CN1POF-H  
CN1POF-C  
CN1AUDV1  
CN1AUDV2  
CN1AUDV3  
CN1BRLV1  
CN1BRLV2  
CN1BRLV3  
+12V  
アオ 25 BLU  
CV1AUDV2  
NC  
CN1AUDV3  
GND  
ミドリ GRN  
クロ  
アカ  
クロ  
BLK  
RED  
BLK  
AA MSR_GND  
BB MSPITCH  
CC MSP_GND  
JJ PWRHUL-H  
NN PWRHUL-C  
チャ 26 BRN  
ミドリ 26 GRN  
ミドリ 6 GRN  
クロ 6 BLK  
シールド SHIELD  
シンセン CORE  
ミドリ 9 GRN  
10 YEL  
AA  
BB  
CC  
DD  
EE  
FF  
HH  
JJ  
KK  
MM  
NN  
PP  
RR  
SS  
TT  
AA GND  
BB EXTKP-C  
CC EXTKP-H  
PP  
JJ  
RR  
KK  
SS  
NN  
TT  
LL  
ミドリ GRN  
シロ  
ムラ 27 PPL  
ミドリ 27 GRN  
アオ 28 BLU  
+12V  
GND  
+12V  
GND  
+12V  
GND  
+12V  
GND  
シロ 10 WHT  
シロ 11 WHT  
アオ 11 BLU  
ムラ 13 PPL  
シロ 13 WHT  
チャ 12 BRN  
シロ 12 WHT  
PP  
JJ  
RR  
KK  
SS  
NN  
TT  
LL  
P
P
P
P
WHT  
YEL  
WHT  
PP  
TT  
DD  
EE  
CC  
PP  
10  
11  
PWRHUL-H  
PWRHUL-C  
ミドリ 14 GRN  
チャ 14 BRN  
SIG_D6-H  
SIG_D6-C  
P
P
P
P
P
P
シロ  
28 YEL  
チャ 29 BRN  
29 YEL  
ムラ 30 PPL  
キ 30 YEL  
クロ  
アオ  
7 BLK  
7 BLU  
FF SIG_D7-H  
HH SIG_D7-C  
JJ KP-H  
KK KP-C  
MM FS-H  
NN FS-C  
GND MM  
+12V RR  
GND NN  
NC SS  
13 GND  
12 +12V  
14 GND  
CN-C201  
- C220  
アオ 15 BLU  
チャ 15 BRN  
チャ 18 BRN  
シロ 18 WHT  
ムラ 16 PPL  
チャ 16 BRN  
チャ 17 BRN  
ハイ 17 GRY  
TRX 10P6931 x20  
*2  
CN-B201~B220  
ODD(CN-)  
C201  
NC TT  
*7  
CN-A302  
J513  
DS1SPK-H  
CN-A102/107  
J413/423  
EVEN(CN-)  
C202  
P1~P6  
XM2A-2501  
PP  
RR EMB-C  
1
14  
3
1
ENB-H  
ムラ 12 PPL  
クロ 12 BLK  
アカ 13 RED  
シロ 13 WHT  
チャ 11 BRN  
クロ 11 BLK  
アオ 10 BLU  
クロ 10 BLK  
ミドリ 14 GRN  
シロ 14 WHT  
*2  
P
P
P
P
P
P
P
P
P
P
P
P1~P6  
接続箱  
JUNCTION BOX  
FSV-245  
B201 B101  
14 GND  
SS FSCLK-H  
TT FECLK-C  
3
6
5
DS1DVS-N  
GND  
-12V  
C203  
C204  
*2  
*3 *2  
6
P1~P6  
P1~P6  
5
18  
4
17  
7
19  
8
20  
2
23  
12  
9
13  
10  
24  
21  
25  
22  
18 -12V  
C205  
C206  
送受波器  
TRANSDUCER  
B220 B120  
J1-16 J1-16  
4
17  
7
19 GND  
8
20 GND  
2
23 NC  
12 +140V  
9
13 +140V  
10 GND  
24 +140V  
21 GND  
25 +140V  
22 GND  
+12V  
+12V  
P1~P6  
P1~P6  
C207  
C208  
DS1HALLX  
P1~P6  
P1~P6  
15 YEL  
DS1HALLY  
C209  
C210  
アース銅板  
COPPER STRAP  
シロ 15 WHT  
アオ 16 BLU  
シロ 16 WHT  
P1~P6  
P1~P6  
DS1DGN-N  
注記  
C211  
C212  
クロ  
8 YEL  
8 BLK  
*1)造船所手配。  
P1~P6  
P1~P6  
GND  
*2)コネクタは工場にて取付済み。  
*3)オプション。  
C213  
C214  
ミドリ 6 GRN  
延長キット  
EXTENSION KIT  
P1~P6  
P1~P6  
クロ  
アカ  
クロ  
シロ  
クロ  
6 BLK  
4 RED  
4 BLK  
2 WHT  
2 BLK  
*4)コネクタクランプでアースに落とす。  
*5)電源に応じてタップを切り替える。  
*6)00-8016-038-313761HV  
C215  
C216  
P1~P6  
P1~P6  
C217  
C218  
*7)ユニット間ケーブル長は5m以下。延長する  
ときは、延長キット(オプション)を使用。  
P1~P6  
P1~P6  
CN-A104/109  
船内電源  
SHIP'S MAINS  
CN-A304  
CN-A305  
CN-A306  
CN-A307  
CN-A308  
電源装置 FSV-242  
POWER SUPPLY UNIT  
J412/422  
DS1V-R  
GND  
BNC-P  
BNC-P  
BNC-P  
BNC-P  
BNC-P  
J521  
DS1V-R  
GND  
J522  
DS1V-G  
GND  
J523  
DS1V-B  
GND  
J524  
DS1VSY  
GND  
J525  
DS1HSY  
GND  
1
6
ドウジク① CO-AX  
ドウジク② CO-AX  
ドウジク③ CO-AX  
ドウジク④ CO-AX  
ドウジク⑤ CO-AX  
1
2
C219  
P1~P6  
C220  
P1~P6  
NOTE  
*1 *5  
DPYCY-4  
絶縁トランス  
ISOLATION  
TRANSFORMER  
TB-D102  
230V  
220V  
0V  
100/110/115/  
220/230 VAC  
1φ,50/60Hz  
*1: SHIPYARD SUPPLY.  
DS1V-G  
GND  
2
7
1
2
POWER  
TB-B101  
1 AC_IN-H  
2 AC_IN-C  
*2: CONNECTOR PLAGS FITTED AT FACTORY.  
*3: OPTION.  
*1  
DPYCY-4  
MAX.20m  
TB-D101  
110/115V 100V  
DS1V-B  
GND  
3
8
1
2
100V  
0V  
GND  
0V  
*4: GROUNDING THRU CONNECTOR CLAMP  
*5: CHANGE TAPPING CONNECTION AS VOLTAGE.  
*6: 00-8016-038-313761HV  
DS1VSY 14  
5
1
2
CN-A110  
J16  
AC_IN-H  
AC_IN-C  
SHIELD  
GND  
アース銅板  
COPPAR STRAP  
*1  
DPYCY-1.5  
アース銅板  
COPPER STRAP  
NCS-253-P  
100/110/115  
220/230 VAC  
1φ,50/60Hz  
*7: CABLE LENGTH BETWEEN THE UNITS: 5m OR LESS.  
OPTIONAL KIT REQUIRED FOR EXTENSION.  
IV-8SQ.  
3
2
1
13  
10  
1
2
DS1HSY  
GND  
*1  
*2  
KEC-15P  
*1  
IV-8SQ.  
DRAWN  
TITLE  
FSV-24/24S  
T.YAMASAKI  
Jan. 28 '03  
CHECKED  
Jan. 28 '03  
名称  
カラースキャニングソナー  
相互結線図  
Y.KIMURA  
APPROVED  
Jan. 28, '03  
MASS  
SCALE  
NAME  
COLOR SCANNING SONAR  
INTERCONNECTION DIAGRAM  
FURUNO ELECTRIC CO., LTD.  
kg  
DWG No.  
10-071-0103-0  
C1318-C07- A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S - 2  
1
2
3
4
5
6
送受信装置 FSV-241E  
TRANSCEIVER UNIT  
制御部 FSV-2402/2402S  
上下装置  
HULL UNIT  
10S2145,20m *3  
10S2144,10m *3  
10S2078,5m  
(VV-SBCJ-0.3x14P,φ11.4)  
ミドリ GRN  
操作部 FSV-2401  
CONTROL UNIT  
CN-A201  
XHP-15  
J1  
PROCESSOR UNIT  
CN-A103/108  
CN-C101  
J1 *6 *2  
CN-B102  
MSRXD-H  
MSRXD-C  
MSTXD-H  
MSTXD-C  
UPLSW-H  
UPLSW-C  
DEMGUP-H  
CN-B101  
CN-A101  
*6 J445  
*2  
*6 J1  
J2 *6  
A
10S1258-1,φ18,MAX.100m  
アカ 11 RED  
10S2077,10m  
クロ  
J411/421 *6 *2  
*2  
FSV-247  
FSV-248  
A
A
B
C
D
E
F
H
A
B
C
D
E
F
H
TRXRXD-H  
TRXRXD-C  
TRXTXD-H  
TRXTXD-C  
SIG_D0-H  
SIG_D0-C  
DEMGUP-H  
A
B
4 YEL  
4 BLK  
3
4
1
2
5
6
7
8
9
CN1RXD-H  
CN1RXD-C  
CN1TXD-H  
CN1TXD-C  
CN1TXA-H  
CN1TXA-C  
CN1TXB-H  
CN1TXB-C  
CN1TYA-H  
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
アカ  
アオ  
クロ  
RED  
BLU  
BLK  
B
C
D
E
F
H
チャ 11 BRN  
クロ 10 BLK  
シロ 10 WHT  
ダイ 12 ORG  
チャ 12 BRN  
アカ 19 RED  
ダイ 19 ORG  
C
D
E
F
ミドリ 3 GRN  
P
P
P
P
P
P
P
P
P
P
P
P
P
クロ  
アオ  
クロ  
チャ  
クロ  
ムラ  
クロ  
アカ  
シロ  
3 BLK  
5 BLU  
5 BLK  
6 BRN  
6 BLK  
7 PPL  
7 BLK  
8 RED  
8 WHT  
ムラサキ PPL  
A
B
C
D
シロ  
チャ  
クロ  
チャ  
シロ  
アオ  
シロ  
WHT  
BRN  
BLK  
BRN  
WHT  
BLU  
WHT  
YEL  
BLK  
WHT  
BLK  
J
TT  
LL DEMGUP-C  
LL  
J
LL DEMGUP-C  
K
J
K
N
P
R
S
T
U
V
X
W
Y
Z
MDLSW-H  
MDLSW-C  
DNLSW-H  
DNLSW-C  
DNCMD-H  
DNCMD-C  
UPCMD-H  
UPCMD-C  
DUPLSW-H  
DUPLSW-C  
TSFLG-H  
TSFLG-C  
MSROLL  
クロ  
ハイ  
9 BLK  
9 GRY  
13 YEL  
J
K
L
M
N
P
R
S
T
U
V
X
W
Y
Z
SIG_D1-H  
SIG_D1-C  
SIG_D2-H  
SIG_D2-C  
SIG_D3-H  
SIG_D3-C  
SIG_D4-H  
SIG_D4-C  
SIG_D5-H  
SIG_D5-C  
DUPLSW-H  
DUPLSW-C  
AUDIO-H  
AUDIO-C  
+12V  
L
M
N
P
JJ  
KK  
LL  
K
L
M
N
P
R
S
T
U
V
X
W
Y
Z
10 CN1TYA-C  
11 CN1TYB-H  
12 CN1TYB-C  
TB-C101  
U
V
W
1
2
3
4
5
6
7
8
チャ 13 BRN  
13  
クロ  
ムラ  
ダイ  
クロ  
クロ  
アカ  
クロ  
チャ  
クロ  
8 BLK  
8 PPL  
4 ORG  
4 BLK  
3 BLK  
3 RED  
5 YEL  
5 BLK  
2 BRN  
2 BLK  
ミドリ 14 GRN  
アカ 14 RED  
GND  
クロ  
シロ  
クロ  
14 GND  
15 GND  
ムラサキ PPL  
CN-A202  
J2  
CN1PON-H  
XHP-14  
1
R
S
T
U
V
クロ  
アカ  
シロ  
BLK  
RED  
WHT  
シロ  
クロ  
アカ  
クロ  
シロ  
1 WHT  
1 BLK  
2 RED  
2 BLK  
9 WHT  
P
P
P
P
P
P
P
2
3
4
5
6
7
8
9
CN1PON-C  
CN1POF-H  
CN1POF-C  
CN1AUDV1  
CN1AUDV2  
CN1AUDV3  
CN1BRLV1  
CN1BRLV2  
CN1BRLV3  
+12V  
ミドリ GRN  
クロ  
アカ  
クロ  
BLK  
RED  
BLK  
AA MSR_GND  
BB MSPITCH  
CC MSP_GND  
JJ PWRHUL-H  
NN PWRHUL-C  
X
ミドリ 6 GRN  
クロ 6 BLK  
シールド SHIELD  
シンセン CORE  
ミドリ 9 GRN  
10 YEL  
AA  
BB  
CC  
DD  
EE  
FF  
HH  
JJ  
KK  
MM  
NN  
PP  
RR  
SS  
TT  
AA GND  
BB EXTKP-C  
CC EXTKP-H  
Z
W
Y
ミドリ GRN  
シロ  
シロ 10 WHT  
シロ 11 WHT  
アオ 11 BLU  
ムラ 13 PPL  
シロ 13 WHT  
チャ 12 BRN  
シロ 12 WHT  
WHT  
YEL  
WHT  
PP  
TT  
DD  
EE  
CC  
PP  
MM  
RR  
NN  
SS  
TT  
10  
11  
PWRHUL-H  
PWRHUL-C  
ミドリ 14 GRN  
チャ 14 BRN  
SIG_D6-H  
SIG_D6-C  
P
P
P
P
P
P
シロ  
クロ  
アオ  
7 BLK  
7 BLU  
FF SIG_D7-H  
HH SIG_D7-C  
JJ KP-H  
KK KP-C  
MM FS-H  
NN FS-C  
13 GND  
12 +12V  
14 GND  
CN-C201  
- C220  
アオ 15 BLU  
チャ 15 BRN  
チャ 18 BRN  
シロ 18 WHT  
ムラ 16 PPL  
チャ 16 BRN  
チャ 17 BRN  
ハイ 17 GRY  
TRX 10P6931 x20  
*2  
CN-B201~B220  
ODD(CN-)  
C201  
*7  
EVEN(CN-)  
C202  
P1~P6  
PP  
RR EMB-C  
ENB-H  
P1~P6  
接続箱  
JUNCTION BOX  
FSV-245  
B201 B101  
SS FSCLK-H  
TT FECLK-C  
C203  
C204  
*2  
*3 *2  
P1~P6  
P1~P6  
C205  
P1~P6  
C206  
P1~P6  
送受波器  
TRANSDUCER  
B220 B120  
J1-16 J1-16  
C207  
P1~P6  
C208  
P1~P6  
C209  
P1~P6  
C210  
P1~P6  
アース銅板  
COPPER STRAP  
注記  
外部モニター  
EXTERNAL MONITOR  
*1  
C211  
P1~P6  
C212  
P1~P6  
*1)造船所手配。  
CN-A104/109  
J412/422  
*1  
MONITOR CABLE  
*2)コネクタは工場にて取付済み。  
*3)オプション。  
C213  
P1~P6  
C214  
P1~P6  
KEC-15P  
DS1V-R  
GND  
DS1V-G  
GND  
DS1V-B  
GND  
1
6
2
7
3
8
延長キット  
EXTENSION KIT  
*4)コネクタクランプでアースに落とす。  
*5)電源に応じてタップを切り替える。  
*6)00-8016-038-313761HV  
C215  
P1~P6  
C216  
P1~P6  
C217  
P1~P6  
C218  
P1~P6  
船内電源  
SHIP'S MAINS  
*7)ユニット間ケーブル長は5m以下。延長する  
ときは、延長キット(オプション)を使用。  
DS1VSY 14  
GND  
電源装置 FSV-242  
POWER SUPPLY UNIT  
5
C219  
P1~P6  
C220  
P1~P6  
DS1HSY 13  
GND 10  
絶縁トランス  
ISOLATION  
TRANSFORMER  
NOTE  
*1 *5  
DPYCY-4  
100/110/115/  
220/230 VAC  
1φ,50/60Hz  
TB-D102  
230V  
220V  
0V  
*1: SHIPYARD SUPPLY.  
CN-A110  
J16  
AC_IN-H  
AC_IN-C  
SHIELD  
POWER  
TB-B101  
1 AC_IN-H  
2 AC_IN-C  
*1  
DPYCY-1.5  
*2: CONNECTOR PLAGS FITTED AT FACTORY.  
*3: OPTION.  
NCS-253-P  
*1  
DPYCY-4  
MAX.20m  
TB-D101  
110/115V 100V  
3
2
1
100V  
0V  
GND  
0V  
*4: GROUNDING THRU CONNECTOR CLAMP  
*5: CHANGE TAPPING CONNECTION AS VOLTAGE.  
*6: 00-8016-038-313761HV  
*1  
IV-8SQ.  
アース銅板  
COPPAR STRAP  
アース銅板  
COPPAR STRAP  
*7: CABLE LENGTH BETWEEN THE UNITS: 5m OR LESS.  
OPTIONAL KIT REQUIRED FOR EXTENSION.  
100/110/115/  
220/230 VAC  
1φ,50/60Hz  
DRAWN  
TITLE  
名称  
FSV-24/24S  
T.YAMASAKI  
Y.KIMURA  
Jan. 28 '03  
CHECKED  
Jan. 28 '03  
カラースキャニングソナー  
相互結線図  
APPROVED  
Jan. 28, '03  
MASS  
SCALE  
NAME  
COLOR SCANNING SONAR  
INTERCONNECTION DIAGRAM  
FURUNO ELECTRIC CO., LTD.  
kg  
DWG No.  
C1318-C08- A  
10-071-0103-0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-3  
1
2
3
PCS-E68PM  
J14 PC IF  
MONITOR J1  
MD-R  
GND  
KEC-15P  
データ収録装置  
DATA RECORDER  
外部モニター  
EXTERNAL MONITOR  
1
1
6
2
7
3
8
制御部  
メンテナンス専用  
FOR MAINTENANCE  
MD-G  
GND  
MD-B  
GND  
PROCESSOR UNIT  
FSV-2402/2402S  
FSV-3002/3002S  
FSV-8402  
68  
*4  
MD-V-SYNC 14  
GND  
MD-H-SYNC  
A
B
C
D
*2  
02S8040,6m  
SRCN6A16-10P  
5
13  
ES2/NET  
J12  
ES2-SIG-IN  
GND  
KP-DN-IN  
NC  
ES2-WL-IN  
GND  
GND  
KP-UP-IN  
NC  
魚探 I/F  
ES I/F  
VI-1100A  
1
2
3
4
5
6
7
8
9
GND 10  
*4  
*3  
MJ-A6SPF  
*2  
MJ-A6SPF0011/0012 航法装置  
5/10m,φ6  
NMEA1  
NMEA1-TXD-H  
J3  
1
2
3
4
6
NAVIGATOR  
NMEA1-TXD-C  
NMEA1-RXD-H  
NMEA1-RXD-C  
SHIELD  
*4  
10 GND  
*3  
MJ-A6SPF  
*4  
*2  
SRCN6A21-10S  
*2  
MJ-A6SPF0011/0012 航法装置  
NMEA2/CIF2  
J4  
*2  
外部KP CO-0.2x5P  
EXTERNAL KP  
*5  
1
2
3
4
6
NMEA2-TXD-H  
NMEA2-TXD-C  
NMEA2-RXD-H  
NMEA2-RXD-C  
SHIELD  
EXT-KP  
J13  
INTKP1  
GND  
INTKP2  
GND  
INTKP3  
GND  
GND  
EXT-KP-IN-H  
EXT-KP-IN-C  
5/10m,φ6  
NAVIGATOR  
1
2
3
4
5
6
7
8
9
*4  
*2  
CO-0.2x2P  
SRCN6A13-5P  
P
CIF1  
J5  
1
2
3
4
5
CIF-TXD-H  
CIF-TXD-C  
CIF-RXD-H  
CIF-RXD-C  
SHIELD  
潮流計  
CURRENT INDICATOR  
P
10 EXT-12VKP-IN  
*4  
*4  
CN-A105  
J15  
1
2
3
4
5
6
7
8
AUX  
J6  
NC  
17JE-13260-02(D1)  
パソコン  
PC  
メンテナンス専用  
FOR MAINTENANCE  
1
2
3
7
AUX-TXD  
AUX-RXD  
GND  
NC 25  
*4  
*2  
SRCN6A16-10P  
*2  
GYRO  
J7  
外部スピーカ  
EXTERNAL SPEAKER  
SEM-21Q  
CO-0.2x2P ADコンバータ  
AD CONVERTER  
AD-100  
CN-A106  
AD-DATA-H  
AD-DATA-C  
AD-CLK-H  
AD-CLK-C  
2
3
6
7
P
2.8m  
1
2
SP-AUDIO  
GND  
P
NJC-203PM  
SHIELD 10  
J17 CS-120A  
+24VDC  
0V  
*4  
*2  
SRCN6A13-3P  
CS-120A  
1
2
3
*1  
DPYC-1.5  
LOG  
LOG  
GND  
NC  
J8  
スピードログ  
SPEED LOG  
SHIELD  
1
2
3
FNZ-AUX  
J11  
*4  
*2  
SRCN6A16-7P  
SRCN2A21-16S  
1
2
3
4
5
6
7
8
9
SONDE_3  
GND  
SONDE_4  
GND  
SONDE_5  
GND  
SONDE_6  
GND  
SONDE_7  
予備  
RESERVE  
*2  
02S8040,6m 魚探I/F  
ES1  
ES1-SIG-IN  
GND  
ES1-KP-IN  
NC  
ES1-WL-IN  
SHIELD  
GND  
J9  
1
2
3
4
5
6
7
ES I/F  
VI-1100A  
注記  
*1)造船所手配  
*2)オプション。  
*3)コネクタは工場にて取付済み。  
*4  
*2  
SRCN6A21-10P  
10 GND  
11  
*4)コネクタクランプでアースに落とす。  
*5)IFES基板S2 #8にて選択。  
工場出荷時はCIF(OFF)。  
*1  
CO-0.2x5P ネットゾンデ  
NET SONDE  
SONDE_8  
FNZ  
J10  
SONDE_0  
GND  
SONDE_1  
GND  
SONDE_2  
GND  
SONDE_KP  
GND  
SONDE_WL  
12 GND  
13 SONDE_9  
14 GND  
1
2
3
4
5
6
7
8
9
16  
GND  
NOTE  
*1: SHIPYARD SUPPLY.  
*2: OPTION.  
*3: CONNECTOR PLAG FITTED AT FACTORY.  
*4: GROUND THRU CONNECTOR CLAMP.  
*5: SELECT CIF OR NMEA AT S2 #8 ON  
IFES BOARD. DEFAULT IS CIF (OFF).  
GND 10  
*4  
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5  
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5  
DRAWN  
Dec. 26 '06  
CHECKED  
TITLE  
FSV-2402/2402S/3002/3002S/8402  
制御部外部信号接続  
E.MIYOSI  
名称  
NAME  
TAKAHASHI. T  
Y. Hatai  
MASS  
kg  
APPROVED  
SCALE  
相互結線図  
FSV-24/24S/30/30S/84/84L  
PROCESSOR UNIT EXTERNAL INTERFACE  
INTERCONNECTION DIAGRAM  
DWG.No.  
C1318-C03- N  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-3A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EAW Speaker System SB250zR User Manual
Electro Voice Speaker System ND6 16 User Manual
Extron electronic Network Card IPI 101 User Manual
Franke Consumer Products Convection Oven CA 52M User Manual
Freshtel Modem 64xx User Manual
Frigidaire Oven FGEW2745K User Manual
FujiFilm Digital Camera S2 Pro User Manual
Fujitsu Printer FTP 632MCL301 User Manual
Garland Griddle CG 48F User Manual
Gizzmo Electronics Iron SW112 DVB User Manual