Single Wall Ovens
FGEW2745K F/ꢀW/ꢀB
27" Electric
Powerful Performance
Effortless™ Convection Conversion
Power and Quick Clean Options
Broil (ꢀ3,400Wꢀ)
Performance-Driven Style
Real Stainless Steel
Even Baking Technology
One-Touch Options
Keep Warm
Chicken Nuggets
More Easy-To-Use Features
Hidden Bake
Extra-Large Window
ADA Compliant*
Sabbath Mode (Star-K® Certified)
Capacities
3.5 Cu.ꢀFt. Oven Capacity
Overall Exterior Dimensions
Height
Width
Depth
29"
27"
24-1/2"
Available in:
Signature Features
Stainless
(F)
White
(W)
Black
(B)
*ꢀWhen properly installed, meets the appliance standards
in the American with Disabilities Act and the Architectural
Barriers Act Accessibility Guidelines as published by the
United States Access Board on June 23, 2004.
1ꢀBased on single rack cooking performance, not set
temperature, using PowerPlus™ Preheat.
Quick Preheat
True Convection
Preheat in less than six minutes.1
Multi-rack baking is faster and more
even with True Convection.
Express-Select™ Controls
Easily set cooking temperature or
choose one-touch cooking options.
Keep Warm Setting
Keep food warm until everything —
and everyone — is ready.
frigidaire.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Electric Cooktop Installation
Over 30"/27"ꢀElectric Single Wall Oven
30"/ꢀ27" Electric Single Wall Oven
Under-Counter Installation Specifications
Electric Cooktop Installation Over
30"/ꢀ27" Electric Single Wall Oven Specifications
•
Single phase 3- or 4-wire cable, 120ꢀ/ꢀ240 or 120ꢀ/ꢀ208 Volt, 60 Hertz
All Frigidaire® Electric Single Wall Ovens are approved to be used
beneath any approved Frigidaire® Electric Cooktop.
For detailed Electric Cooktop installation, refer to model-specific
product page and installation guide on web.
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
•
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
Always consult local and national electric codes.
•
Side filler panels necessary to isolate oven from adjoining cabinets.
Panel height may need to be modified to accommodate the depth
of approved electric cooktop models.
•
•
•
Minimum 21" clearance for oven door depth when open.
•
•
To route armored cable to junction box, cut minimum 4" x 4" opening
in right cabinet side panel.
Allow 4-1/2" maximum height from oven base to floor, if cooktop is
installed directly over wall oven.
Minimum 23-1/2" deep cutout dimension is critical for proper
installation, to ensure that oven’s faceplate will fit flush against
cabinet front.
Full oven base of solid plywood or similar material required,
capable of supporting 200 Lbs. Install over two runners and flush
with toe plate.
Base must be level and cabinet front must be square.
Allow 5" maximum height from oven base to floor, if NO cooktop is
installed directly over wall oven.
•
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
•
•
FRIGIDAIRE
•
•
•
•
•
USA Electrolux Major Appliances, North America 250 Bobby Jones Expressway Martinez, GA 30907 1-800-FRIGIDAIRE frigidaire.com
Specifications
subject to change.
•
•
•
•
•
CANADA Electrolux Canada Corporation 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca
EC_EW INST FR 04/09
Printed in the U.S.A.
Download from Www.©So20m0a9nEuleacltsro.cluoxmH.omAellPMroadnuuctasl,sInSc.earch And Download.
Gas Cooktop Installation
Over 30"/27"ꢀElectric Single Wall Oven
30"/ꢀ27" Electric Single Wall Oven
Under-Counter Installation Specifications
Gas Cooktop Installation Over
30"ꢀ/ꢀ27" Electric Single Wall Oven Specifications
•
Single phase 3- or 4-wire cable, 120ꢀ/ꢀ240 or 120ꢀ/ꢀ208 Volt, 60 Hertz
All Frigidaire® Electric Single Wall Ovens are approved to be used
beneath any approved Frigidaire® Gas Cooktop.
For detailed Gas Cooktop installation, refer to model-specific product
page and installation guide on web.
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
•
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
Always consult local and national electric codes.
•
•
•
Side filler panels necessary to isolate oven from adjoining cabinets.
Panel height may need to be modified to accommodate the depth
of approved gas cooktop models.
Minimum height opening of 6-1/2" (from top of counter) required
in right cabinet side panel and/or filler panel, to route gas and
electric hookups.
•
•
•
Minimum 21" clearance for oven door depth when open.
Minimum 23-1/2" deep cutout dimension is critical for proper
installation, to ensure that oven’s faceplate will fit flush against
cabinet front.
Full oven base of solid plywood or similar material required,
capable of supporting 200 Lbs. Install over two runners and flush
with toe plate.
Base must be level and cabinet front must be square.
Allow 5" maximum height from oven base to floor, if NO cooktop is
installed directly over wall oven.
Allow 4-1/2" maximum height from oven base to floor, if cooktop is
installed directly over wall oven.
•
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
•
•
FRIGIDAIRE
•
•
•
•
•
USA Electrolux Major Appliances, North America 250 Bobby Jones Expressway Martinez, GA 30907 1-800-FRIGIDAIRE frigidaire.com
Specifications
subject to change.
•
•
•
•
•
CANADA Electrolux Canada Corporation 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca
GC_EW INST FR 04/09
Printed in the U.S.A.
Download from Www.©So20m0a9nEuleacltsro.cluoxmH.omAellPMroadnuuctasl,sInSc.earch And Download.
27"ꢀCombination Installation
Built-In Microwaveꢀ/ꢀSingle Wall Ovenꢀ
27" Combination Installation Specifications
27" Electric Single Wall Oven Specifications
•
•
Always consult local and national electric codes.
Single phase 3- or 4-wire cable, 120ꢀ/ꢀ240 or 120ꢀ/ꢀ208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
Full base of solid plywood or similar material required, capable of
supporting 200 Lbs.
To adapt oven to fit cutout height greater than 28-1/8", add one
2"-wide wood shim of appropriate height to each side of opening
under oven side rails. Lifting oven will hide larger cutout opening
at top and oven’s 1"-high bottom trim will hide shims at bottom.
(Standard 1"- High Bottom Trim included.)
(Refer to product-specific electrical specifications on this page.)
•
Minimum 23-1/2" deep cutout dimension is critical for proper
combination installation, to ensure that each built-in product’s
faceplate will fit flush against cabinet front.
Bases must be level and cabinet front must be square.
Minimum 4-1/2" required distance from bottom of Wall Oven cutout
to floor, 31" suggested.
Respect critical dimensions as noted for proper installation of
built-In products.
Minimum 21" clearance needed for Wall Oven door depth when open.
•
•
•
•
•
•
•
27" Built-In Microwave Specifications
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
•
For built-in installation, microwave MUST be installed with optional
27" Trim Kit which includes Bottom Duct Assembly – shipped in
separate box, ordered by individual part number.
•
•
Voltage Rating – 120Vꢀ/ꢀ60 Hzꢀ/ꢀ15 or 20 Amps
Connected Load (kW Rating) @ 120 Volts = 1.7 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
•
Amps @ 120 Volts = 14.3 Amps
Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
•
Minimum 2-7/8" clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap
between both product faceplates.
FRIGIDAIRE
•
•
•
•
•
USA Electrolux Major Appliances, North America 250 Bobby Jones Expressway Martinez, GA 30907 1-800-FRIGIDAIRE frigidaire.com
Specifications
subject to change.
•
•
•
•
•
CANADA Electrolux Canada Corporation 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca
MOSS_EW 27INST FR 04/09 © 2009 Electrolux Home Products, Inc.
Printed in the U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
27"ꢀCombination Installation
Built-In Microwaveꢀ/ꢀSingle Wall Ovenꢀ/ꢀWarmer Drawer
27" Combination Installation Specifications
27" Electric Single Wall Oven Specifications
•
•
Always consult local and national electric codes.
Single phase 3- or 4-wire cable, 120ꢀ/ꢀ240 or 120ꢀ/ꢀ208 Volt, 60 Hertz
AC only electrical supply with ground required on separate circuit
fused on both sides of line.
For detailed electrical requirements, refer to model-specific product
page and installation guide on web.
To support Wall Oven when using in combination with Warmer
Drawer, two 3"-wide x 3/4"-thick planks must be installed as a base,
capable of supporting 200 Lbs. Do NOT use full base, since planks
are necessary to allow for proper air displacement.
(Refer to product-specific electrical specifications on this page.)
•
Minimum 23-5/8" deep cutout dimension is critical for proper
combination installation, to ensure that each built-in product’s
faceplate will fit flush against cabinet front.
Bases must be level and cabinet front must be square.
Minimum 4-1/2" required distance from bottom of Warmer Drawer
cutout to floor.
Respect critical dimensions as noted for proper installation of
built-In products.
Minimum 21" clearance needed for Wall Oven door depth when open.
•
•
•
•
•
•
27" Warmer Drawer Specifications
• Voltage Rating – 120Vꢀ/ꢀ450Wꢀ/ꢀ60 Hzꢀ/ꢀ15 Amps
• Connected Load (kW Rating) @ 120 Volts = 0.5 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
• Amps @ 120V = 3.8 Amps
• Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
27" Built-In Microwave Specifications
•
For built-in installation, microwave MUST be installed with optional
27" Trim Kit which includes Bottom Duct Assembly – shipped in
separate box, ordered by individual part number.
•
•
Voltage Rating – 120Vꢀ/ꢀ60 Hzꢀ/ꢀ15 or 20 Amps
Connected Load (kW Rating) @ 120 Volts = 1.7 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
•
•
Amps @ 120 Volts = 14.3 Amps
Full base of solid plywood or similar material required, capable of
supporting 100 Lbs.
•
Minimum 2-7/8" clearance required from bottom of Built-In Microwave
cutout to top edge of Wall Oven’s faceplate, leaving a 2" visible gap
between both product faceplates.
FRIGIDAIRE
•
•
•
•
•
USA Electrolux Major Appliances, North America 250 Bobby Jones Expressway Martinez, GA 30907 1-800-FRIGIDAIRE frigidaire.com
Specifications
subject to change.
•
•
•
•
•
CANADA Electrolux Canada Corporation 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca
MOSS_EW_WD 27INST FR 04/09 © 2009 Electrolux Home Products, Inc.
Printed in the U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
|