Furuno Power Supply M51A User Manual

DLM 600W Series  
Power Supplies  
M51A Option: Isolated Analog  
Programming Manual  
Power Supplies  
Elgar Electronics Corporation  
9250 Brown Deer Road  
San Diego, CA 92121-2294  
1-800-73ELGAR (1-800-733-5427)  
Tel: (858) 450-0085  
Fax: (858) 458-0267  
©2002 by Elgar Electronics Corporation  
This document contains information proprietary to Elgar Electronics Corporation. The information contained herein is  
not to be duplicated or transferred in any manner without prior written permission from Elgar Electronics Corporation.  
August 21, 2002  
Document No. M362299-01 Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY NOTICE  
Before applying power to the system, verify that the instrument is configured properly for the user’s  
particular application.  
WARNING!  
Hazardous voltages may be present when covers are  
removed. Qualified personnel must use extreme caution  
when servicing this equipment. Circuit boards, test points,  
and output voltages also may be floating with respect to  
chassis ground.  
Installation and servicing must be performed by qualified personnel who are aware of dealing  
properly with attendant hazards. This includes such simple tasks as fuse verification.  
Ensure that the AC power line ground is connected properly to the chassis. Similarly, other  
power ground lines including those to application and maintenance equipment must be grounded  
properly for both personnel and equipment safety.  
Always ensure that facility AC input power is de-energized prior to connecting or disconnecting any  
cable.  
In normal operation, the operator does not have access to hazardous voltages within the chassis.  
However, depending on the user’s application configuration, HIGH VOLTAGES HAZARDOUS TO  
HUMAN SAFETY may be normally generated on the output terminals. The customer/user must  
ensure that the output power lines are labeled properly as to the safety hazards and that any  
inadvertent contact with hazardous voltages is eliminated.  
Guard against risks of electrical shock during open cover checks by not touching any portion of the  
electrical circuits. Even when power is off, capacitors may retain an electrical charge. Use safety  
glasses during open cover checks to avoid personal injury by any sudden component failure.  
Some circuits are live even with the front panel switch turned off. Service, fuse verification, and  
connection of wiring to the chassis must be accomplished at least five minutes after power has  
been removed via external means; all circuits and/or terminals to be touched must be safety  
grounded to the chassis.  
These operating instructions form an integral part of the equipment and must be available to the  
operating personnel at all times. All the safety instructions and advice notes are to be followed.  
Neither Elgar Electronics Corporation, San Diego, California, USA, nor any of the subsidiary sales  
organizations can accept any responsibility for incidental or consequential injury of personnel, or  
loss or damage of equipment or material that results from improper use of the equipment and  
accessories.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY SYMBOLS  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELGAR FIVE–YEAR WARRANTY  
Elgar Electronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in  
material and workmanship. This warranty is effective for one year from the date of shipment of the product to  
the original purchaser. Liability of Elgar under this warranty shall exist provided that:  
the Buyer exposes the product to normal use and service and provides normal maintenance on the  
product;  
Elgar is promptly notified of defects by the Buyer and that notification occurs within the warranty period;  
the Buyer receives a Return Material Authorization (RMA) number from Elgar’s Repair Department prior to  
the return of the product to Elgar for repair, phone 800-73-ELGAR (800-733-5427), ext. 2295;  
the Buyer returns the defective product in the original, or equivalent, shipping container;  
if, upon examination of such product by Elgar it is disclosed that, in fact, a defect in materials and/or  
workmanship does exist, that the defect in the product was not caused by improper conditions, misuse,  
or negligence; and,  
that Elgar QA seal and nameplates have not been altered or removed and the equipment has not been  
repaired or modified by anyone other than Elgar authorized personnel.  
This warranty is exclusive and in lieu of all other warranties, expressed or implied, including, but not limited  
to, implied warranties of merchantability and fitness of the product to a particular purpose. Elgar, its agents,  
or representatives shall in no circumstance be liable for any direct, indirect, special, penal, or consequential  
loss or damage of any nature resulting from the malfunction of the product. Remedies under this warranty  
are expressly limited to repair or replacement of the product.  
CONDITIONS OF WARRANTY  
To return a defective product, contact an Elgar representative or the Elgar factory for an RMA number.  
Unauthorized returns will not be accepted and will be returned at the shipper’s expense.  
For Elgar products found to be defective within thirty days of receipt by the original purchaser, Elgar will  
absorb all ground freight charges for the repair. Products found defective within the warranty period, but  
beyond the initial thirty-day period, should be returned prepaid to Elgar for repair. Elgar will repair the unit  
and return it by ground freight pre-paid.  
Normal warranty service is performed at Elgar during the weekday hours of 7:30 am to 4:30 pm Pacific  
time. Warranty repair work requested to be accomplished outside of normal working hours will be subject to  
Elgar non-warranty service rates.  
Warranty field service is available on an emergency basis. Travel expenses (travel time, per diem expense,  
and related air fare) are the responsibility of the Buyer. A Buyer purchase order is required by Elgar prior to  
scheduling.  
A returned product found, upon inspection by Elgar, to be in specification is subject to an inspection fee and  
applicable freight charges.  
Equipment purchased in the United States carries only a United States warranty for which repair must be  
accomplished at the Elgar factory.  
Committed to Quality...Striving for Excellence  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page intentionally left blank.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
SECTION 1 M51A OPTION OVERVIEW  
1.1 Introduction...................................................................................................... 1-1  
1.2 General Description......................................................................................... 1-1  
1.3 Specifications................................................................................................... 1-2  
1.3.1 Electrical Specifications....................................................................... 1-2  
1.3.2 Supplemental Characteristics.............................................................. 1-2  
SECTION 2 ISOLATED REMOTE ANALOG INTERFACE OPERATION  
2.1 INTFC SETUP Switch...................................................................................... 2-1  
2.1.1 INTFC SETUP Switch Functions......................................................... 2-2  
2.2 SETUP Switch ................................................................................................. 2-2  
2.3 Isolated Analog Interface Connector ............................................................... 2-3  
2.3.1 ISOLATED ANALOG INTERFACE Functions ..................................... 2-5  
2.4 Remote Programming Configuration ............................................................... 2-7  
2.4.1 Voltage Source Programming of Output Voltage................................. 2-8  
2.4.2 Voltage Source Programming of Output Current................................. 2-8  
2.4.3 Voltage Source Programming of OVP................................................. 2-8  
2.4.4 Resistance Programming of Output Voltage ....................................... 2-9  
2.4.5 Resistance Programming of Output Current........................................ 2-9  
2.4.6 Resistance Programming of OVP...................................................... 2-10  
2.4.7 4-20mA Current Source Programming of Output Voltage ................. 2-10  
2.4.8 4-20mA Current Source Programming of Output Current.................. 2-10  
2.5 EXTERNAL-OFF Control............................................................................... 2-11  
2.6 Remote Monitoring ........................................................................................ 2-11  
2.7 Remote Digital Status Signals ....................................................................... 2-12  
M51A Option  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
DLM 600W Series  
LIST OF TABLES  
Table 2–1. INTFC SETUP Switch............................................................................... 2-1  
Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout .............................. 2-4  
Table 2–3. Remote Programming Configuration Options........................................... 2-7  
Table 2–4. Remote Monitoring................................................................................. 2-11  
Table 2–5. Remote Digital Status Signals ............................................................... 2-12  
LIST OF FIGURES  
Figure 2–1. Rear Panel View, Low–Voltage Models................................................... 2-3  
Figure 2–2. Rear Panel View, High–Voltage Models.................................................. 2-3  
vi  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1  
M51A OPTION OVERVIEW  
1.1 Introduction  
This addendum is to be used in conjunction with the DLM 600W Series Power Supplies  
Operation Manual, Sorensen Document No. M362161-01.  
The Sorensen M51A Option for the DLM 600W Series power supplies provides a remote analog  
interface, which has safety isolation from the output terminals. This allows the remote analog  
interface to be connected to user accessible (SELV) control circuits, even though the output  
terminals were floated at a high potential with respect to the chassis.  
1.2 General Description  
The M51A Option provides isolation for all programming, monitoring, and digital I/O signals that  
are available through the remote analog interface. This isolation barrier eliminates the  
connection that exists in the standard DLM models between the non-isolated remote interface  
circuits and the output return (negative) terminal. The M51A Option remote analog signals are  
referenced to chassis, and could be user accessible irrespective of the float potentials that exist  
at the output terminals.  
The M51A Option provides a full complement of programming, monitoring, and control methods.  
Remote programming is available for output voltage, current, and overvoltage protection (OVP).  
Analog output monitor signals are available for the output voltage and current. Digital I/O  
signals provide indication of the operational state, and a means of enabling the remote interface  
and the output.  
The type and range of the control and monitor signals are user-selectable with a rear panel  
setup switch. The output voltage, current, and OVP could be programmed with a 0-5VDC,  
0-10VDC, or 0-5kresistance; in addition, the output voltage and current could be programmed  
with 4-20mA signals. The output voltage and current monitors could produce 0-5VDC,  
0-10VDC, or 4-20mA signals. Isolated 1mA current sources are provided to facilitate the  
utilization of 0-5kprogramming resistances.  
Except for the isolated remote analog interface, the installation and operation of the DLM 600W  
Series power supplies remains as presented in the Operation Manual. The following sections  
provide a detailed description of the new features and the differences in operation.  
M51A Option  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M51A Option Overview  
DLM 600W Series  
1.3 Specifications  
1.3.1  
Electrical Specifications  
Remote Voltage Programming Accuracy, 0-5/10V Inputs:  
Output Voltage: 0.5% of Vmax  
Output Current: 0.75% of Imax  
OVP: 1.0% of 1.1 X Vmax  
Remote 4-20mA Programming Accuracy:  
Output Voltage: 0.75% of Vmax  
Output Current: 1.0% of Imax  
1.3.2  
Supplemental Characteristics  
Remote Resistance Programming Accuracy, 0-5kInput:  
Output Voltage: 1.0% of Vmax  
Output Current: 1.5% of Imax  
OVP: 1.5% of 1.1 X Vmax  
Remote Monitor Accuracy:  
Output Voltage, 0-5/10V ranges: 0.5% of Vmax  
Output Voltage, 4-20mA: 0.75% of Vmax  
Output Current, 0-5/10V ranges: 0.75% of Imax  
Output Current, 4-20mA: 1.0% of Imax  
1-2  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2  
ISOLATED REMOTE ANALOG  
INTERFACE OPERATION  
2.1 INTFC SETUP Switch  
The INTFC SETUP (Interface Setup) switch is accessible from the rear panel of the unit. It  
provides user selectability of the programming/monitoring ranges and signal types, as well as  
configuring the power supply for operation under remote control. Setting a switch to the UP  
position enables a function. The factory default settings are all switch positions OFF (down).  
See Figure 2–1 for a rear panel view of low-voltage models DLM5–75M51A, DLM 8–75M51A,  
DLM 20–30M51A, DLM 40–15M51A, and DLM 60–10M51A. Refer to Figure 2–2 for a rear  
panel view of high-voltage models DLM 80–7.5M51A, DLM 150–4M51A, and DLM 300–2M51A.  
Switch  
Position  
Function  
OFF (Down) Position  
ON (Up) Position  
1
V, 10V or 4-20mA Select  
I, 10V or 4-20mA Select  
OVP, 10V Select  
0-5VDC  
0-5VDC  
0-10VDC or 4-20mA  
0-10VDC or 4-20mA  
0-10VDC  
2
3
4
5
0-5VDC  
VMON, 10V Select  
IMON, 10V Select  
0-5VDC or 4-20mA  
0-5VDC or 4-20mA  
0-10VDC  
0-10VDC  
EXT-OFF, Active-Low  
Select  
6
Active-High Logic Level Active-Low Logic Level  
Enable Front Panel  
Lockout Front Panel  
Controls  
7
8
LCK-OUT  
Not Used  
Table 2–1. INTFC SETUP Switch  
M51A Option  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolated Remote Analog Interface Operation  
DLM 600W Series  
2.1.1  
INTFC SETUP Switch Functions  
The following sections describe the functions of the various switch positions:  
V, 10V or 4-20mA Select: Position-1, when ON, selects 0-10VDC programming of the output  
voltage. Also, must be set to ON position when the ISOLATED ANALOG INTERFACE  
connector is wired for 4-20mA output voltage programming. When OFF, selects 0-5VDC  
programming of the output voltage.  
I, 10V or 4-20mA Select: Position-2, when ON, selects 0-10VDC programming of the output  
current. Also, must be set to ON position when the ISOLATED ANALOG INTERFACE  
connector is wired for 4-20mA output current programming. When OFF, selects 0-5VDC  
programming of the output current.  
OVP, 10V Select: Position-3, when ON, selects 0-10VDC programming of OVP threshold.  
When OFF, selects 0-5VDC programming of OVP threshold.  
VMON, 10V Select: Position-4, when ON, selects 0-10VDC range for readback of output  
voltage. When OFF, selects 0-5VDC readback of output voltage. Also, must be set to OFF  
position when the ISOLATED ANALOG INTERFACE connector is wired for 4-20mA output  
voltage readback.  
IMON, 10V Select: Position-5, when ON, selects 0-10VDC range for readback of output current.  
When OFF, selects 0-5VDC readback of output current. Also, must be set to OFF position  
when the ISOLATED ANALOG INTERFACE connector is wired for  
4-20mA output current readback.  
EXT-OFF, Active-Low Select: Position-6, when ON, selects the ACTIVE-LOW logic level for  
disabling the output with the EXTERNAL-OFF signal of the ISOLATED ANALOG INTERFACE  
connector. When OFF, selects the ACTIVE-HIGH logic level for disabling the output with the  
EXTERNAL-OFF signal of the Isolated Analog Interface connector.  
LCK-OUT: Position-7, when ON, disables the front panel controls; the front panel  
LOCAL(REMOTE) switch will not toggle between the front panel and remote control.  
Position-8: Not used  
2.2 SETUP Switch  
Only two positions of the SETUP switch remain functional: Position-1, REM SNS, for remote  
sensing selection; Position-2, SLAVE, for master/slave selection. Their operation is the same  
as presented in the Operation Manual. The other switch positions, Position-3 through  
Position-8, are not used.  
2-2  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DLM 600W Series  
Isolated Remote Analog Interface Operation  
Figure 2–1. Rear Panel View, Low–Voltage Models  
Figure 2–2. Rear Panel View, High–Voltage Models  
M51A Option  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolated Remote Analog Interface Operation  
DLM 600W Series  
2.3 Isolated Analog Interface Connector  
The ISOLATED ANALOG INTERFACE connector is a 25-position female  
Subminiature-D type.  
Pin  
1
Function  
ANALOG-CONTROL input  
2
Return for 0-5/10V monitor outputs and EXTERNAL-OFF  
OVP programming input  
3
4
Voltage monitor output, 4-20mA  
5
VOLTAGE-MODE status output  
6
Return for 4-20mA monitor outputs, Auxiliary 5VDC, and digital I/O  
Current monitor output, 0-5/10V  
7
8
1.25VDC output for 4-20mA voltage programming signal  
Voltage programming input  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
Current programming input  
1.25VDC output for 4-20mA current programming signal  
Return for 0-5/10V or resistance programming signals  
Return for 4-20mA current programming signal  
EXTERNAL-OFF input  
Auxiliary 5VDC output (+)  
OVP resistance programming output, 1mA source  
OVP status output  
FAULT status output  
Voltage monitor output, 0-5/10V  
1.25V input for 4-20mA voltage programming signal  
Voltage resistance programming output, 1mA source  
Current resistance programming output, 1mA source  
1.25V input for 4-20mA current programming signal  
Current monitor output, 4-20mA  
Return for 4-20mA voltage programming  
Table 2–2. ISOLATED ANALOG INTERFACE Connector Pinout  
CAUTION  
The signals of the ISOLATED ANALOG INTERFACE have an internal  
connection to chassis ground. Damage could result if the voltage from  
signal returns, Pin-2, 6, 12, 13, and 25, to chassis ground exceeds  
15VDC.  
2-4  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DLM 600W Series  
Isolated Remote Analog Interface Operation  
2.3.1  
ISOLATED ANALOG INTERFACE Functions  
The following sections describe the functions of the various signals of the ISOLATED ANALOG  
INTERFACE. Pin numbers correspond to the connector pinout of Table 2–2.  
Digital Control Input Signals  
ANALOG-CONTROL: Pin-1, enables remote analog programming with an active-high logic  
level of 3-15VDC. An internal 100kpull-down resistor is provided. When ANALOG-  
CONTROL is asserted, the power supply will power-up with the analog interface in control of the  
output voltage. Signal is referenced to Pin-6. Circuit is SELV, and has electrical isolation from  
the output of the unit.  
EXTERNAL-OFF: Pin-14, disables the output when asserted. Active logic level could be  
selected with the INTFC SETUP switch to be high (3-30VDC) or low. An internal 100kpull-  
down resistor is provided. Signal is referenced to Pin-2. Circuit is SELV, and has electrical  
isolation from the output of the unit.  
Digital Control Output Signals  
VOLTAGE-MODE: Pin-5, nominal 5VDC logic level indicates operation in constant-voltage  
mode. Source resistance is 2k. Signal is referenced to Pin-6. Circuit is SELV, and has  
electrical isolation from the output of the unit.  
OVP: Pin-17, nominal 5VDC logic level indicates that the output has been disabled because of  
overvoltage protection. Source resistance is 2k. Signal is referenced to Pin-6. Circuit is  
SELV, and has electrical isolation from the output of the unit.  
FAULT: Pin-18, nominal 5VDC logic level indicates that the output is disabled because of  
overtemperature or summary fault. Source resistance is 2k. Signal is referenced to Pin-6.  
Circuit is SELV, and has electrical isolation from the output of the unit.  
Analog Monitor Signals  
VOLTAGE MONITOR, 0-5/10V: Pin-19, readback of the output voltage is provided with a  
0-5VDC or 0-10VDC signal (user selectable with INTFC SETUP switch) indicating  
0-100% of full scale output. Signal is referenced to Pin-2. Circuit is SELV, and has electrical  
isolation from the output of the unit.  
VOLTAGE MONITOR, 4-20mA: Pin-4, readback of the output voltage is provided with a  
4-20mA signal indicating 0-100% of full scale output. Signal return for the 4-20mA current is  
Pin-6. Circuit is SELV, and has electrical isolation from the output of the unit.  
CURRENT MONITOR, 0-5/10V: Pin-7, readback of the output current is provided with a  
0-5VDC or 0-10VDC signal (user selectable with INTFC SETUP switch) indicating  
0-100% of full scale output. Signal is referenced to Pin-2. Circuit is SELV, and has electrical  
isolation from the output of the unit.  
CURRENT MONITOR, 4-20mA: Pin-24, readback of the output current is provided with a  
4-20mA signal indicating 0-100% of full scale output. Signal return for the 4-20mA current is  
Pin-6. Circuit is SELV, and has electrical isolation from the output of the unit.  
M51A Option  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolated Remote Analog Interface Operation  
DLM 600W Series  
Analog Programming Signals  
OVP PROGRAMMING INPUT: Pin-3, an input signal of 0-5 volts or 0-10 volts (user selectable  
with INTFC SETUP switch) programs the OVP threshold from 5-110% of full scale output  
voltage. Signal is referenced to Pin-12. Circuit is SELV, and has electrical isolation from the  
output of the unit.  
VOLTAGE PROGRAMMING INPUT: Pin-9, an input signal for two methods of programming the  
output voltage: 0-5/10V voltage source or 4-20mA current source.  
An input signal of 0-5VDC or 0-10VDC (user selectable with INTFC SETUP switch) to Pin-9  
programs the output voltage 0-100% of full scale. Signal is referenced to Pin-12.  
An input signal of 4-20mA (user selectable with INTFC SETUP switch) to Pin-9 programs the  
output voltage 0-100% of full scale. Two jumpers are also required:  
Pin-20 to Pin-8; Pin-25 to Pin-12. Signal return for the 4-20mA current is Pin-25; resultant  
burden voltage is referenced to Pin-12.  
Circuits are SELV, and have electrical isolation from the output of the unit.  
CURRENT PROGRAMMING INPUT: Pin-10, an input signal for two methods of programming  
the output current: 0-5/10V voltage source or 4-20mA current source.  
An input signal of 0-5VDC or 0-10VDC (user selectable with INTFC SETUP switch) to Pin-10  
programs the output current 0-100% of full scale. Signal is referenced to Pin-12.  
An input signal of 4-20mA (user selectable with INTFC SETUP switch) to Pin-10 programs the  
output current 0-100% of full scale. Two jumpers are also required:  
Pin-23 to Pin-11; Pin-13 to Pin-12. Signal return for the 4-20mA current is Pin-13; resultant  
burden voltage is referenced to Pin-12.  
Circuits are SELV, and have electrical isolation from the output of the unit.  
OVP RESISTANCE PROGRAMMING OUTPUT: Pin-16 provides a 1mA current source which  
would be connected to Pin-3, OVP PROGRAMMING INPUT, with a 0-5kexternal resistor  
connected between Pin-16 to Pin-12, to program the OVP threshold from 5-110% of full scale  
output voltage. The INTFC SETUP switch Position-3, OVP, must be set to OFF (down) to  
select 0-5VDC input range. Circuit is SELV, and has electrical isolation from the output of the  
unit.  
VOLTAGE RESISTANCE PROGRAMMING OUTPUT: Pin-21 provides a 1mA current source  
which would be connected to Pin-9, VOLTAGE PROGRAMMING INPUT, with a 0-5kexternal  
resistor connected between Pin-21 to Pin-12, to program the output voltage from 0-100% of full  
scale output. The INTFC SETUP switch Position-1, V, must be set to OFF (down) to select  
0-5VDC input range. Circuit is SELV, and has electrical isolation from the output of the unit.  
2-6  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DLM 600W Series  
Isolated Remote Analog Interface Operation  
CURRENT RESISTANCE PROGRAMMING OUTPUT: Pin-22 provides a 1mA current source  
which would be connected to Pin-10, CURRENT PROGRAMMING INPUT, with a 0-5kΩ  
external resistor connected between Pin-22 to Pin-12, to program the output current from  
0-100% of full scale output. The INTFC SETUP switch Position-2, I, must be set to OFF (down)  
to select 0-5VDC input range. Circuit is SELV, and has electrical isolation from the output of the  
unit.  
Auxiliary Sources  
AUXILIARY 5VDC OUTPUT: Pin-15, 5VDC source output for use with logic and programming  
circuits. Source capability is adequate to provide for full scale programming of output voltage,  
current, or OVP when the user connects it to the appropriate programming input(s). Source is  
referenced to Pin-6. Maximum output current is 15mA. Circuit is SELV, and has electrical  
isolation from the output of the unit.  
AUXILIARY 5VDC RETURN: Pin-6, return of 5VDC AUXILIARY source output. Circuit is  
SELV, and has electrical isolation from the output of the unit.  
1.25VDC REFERENCE FOR 4-20mA VOLTAGE PROGRAMMING: Pin-20, provides a  
1.25VDC reference utilized by internal circuits associated with 4-20mA programming of output  
voltage.  
1.25VDC REFERENCE FOR 4-20mA CURRENT PROGRAMMING: Pin-11, provides a  
1.25VDC reference utilized by internal circuits associated with 4-20mA programming of output  
current.  
2.4 Remote Programming Configuration  
Table 2–3 presents the options for remote control operation. Pin numbers refer to the  
ISOLATED ANALOG INTERFACE connector. Switch position numbers refer to the INTFC  
SETUP switch on the rear panel.  
ANALOG-  
CONTROL  
Signal, Pin-1  
LCK-OUT, INTFC  
Setup Switch  
Position-7  
Mode of  
Operation  
Power-Up  
State  
Local/Remote  
Toggling  
Remote Only  
Local Only  
High Level  
Low or Open  
High Level  
ON (Up)  
Off (Down)  
OFF (Down)  
Remote  
Local  
No  
No  
Local/Remote  
Remote  
Yes  
Table 2–3. Remote Programming Configuration Options  
M51A Option  
2-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolated Remote Analog Interface Operation  
DLM 600W Series  
2.4.1  
Voltage Source Programming of Output Voltage  
Setting up for voltage source programming of the output voltage is as follows:  
1.  
2.  
3.  
4.  
5.  
Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming  
range.  
Set Position-1, V, of the INTFC SETUP switch ON (up) for 0-10VDC programming  
range.  
Connect the external programming voltage source to the ISOLATED ANALOG  
INTERFACE connector, with positive to Pin-9 and negative to Pin-12.  
Program the other parameters to the desired limit values: CURRENT PROGRAMMING  
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.4.2  
Voltage Source Programming of Output Current  
Setting up for voltage source programming of the output current is as follows:  
1.  
Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming  
range.  
2.  
3.  
Set Position-2, I, of the INTFC SETUP switch ON (up) for 0-10VDC programming range.  
Connect the external programming voltage source to the ISOLATED ANALOG  
INTERFACE connector, with positive to Pin-10 and negative to Pin-12.  
4.  
5.  
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING  
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.4.3  
Voltage Source Programming of OVP  
Setting up for voltage source programming of OVP is as follows:  
1.  
2.  
Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC  
programming range.  
Set Position-3, OVP, of the INTFC SETUP switch ON (up) for 0-10VDC programming  
range.  
3.  
Connect the external programming voltage source to the ISOLATED ANALOG  
INTERFACE connector, with positive to Pin-3 and negative to Pin-12.  
2-8  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DLM 600W Series  
Isolated Remote Analog Interface Operation  
4.  
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING  
INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to  
Pin-12.  
5.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.4.4  
Resistance Programming of Output Voltage  
Setting up for resistance programming of the output voltage is as follows:  
1.  
2.  
Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming  
range.  
Connect the external programming resistance, 0-5k, to the ISOLATED ANALOG  
INTERFACE connector, from Pin-21 to Pin-12.  
3.  
4.  
Connect a jumper from Pin-21 to Pin-9.  
Program the other parameters to the desired limit values: CURRENT PROGRAMMING  
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12.  
5.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.4.5  
Resistance Programming of Output Current  
Setting up for resistance programming of the output current is as follows:  
1.  
2.  
Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming  
range.  
Connect the external programming resistance, 0-5k, to the ISOLATED ANALOG  
INTERFACE connector, from Pin-22 to Pin-12.  
3.  
4.  
5.  
Connect a jumper from Pin-22 to Pin-10.  
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING  
INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to Pin-12.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
M51A Option  
2-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolated Remote Analog Interface Operation  
DLM 600W Series  
2.4.6  
Resistance Programming of OVP  
Setting up for resistance programming OVP is as follows:  
1.  
2.  
Set Position-3, OVP, of the INTFC SETUP switch to OFF (down) for 0-5VDC  
programming range.  
Connect the external programming resistance, 0-5k, to the ISOLATED ANALOG  
INTERFACE connector, from Pin-16 to Pin-12.  
3.  
4.  
Connect a jumper from Pin-16 to Pin-3.  
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING  
INPUT, Pin-9, and the CURRENT PROGRAMMING INPUT, Pin-10, with respect to pin-  
12.  
5.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.4.7  
4-20mA Current Source Programming of Output Voltage  
Setting up for 4-20mA programming of the output voltage is as follows:  
1.  
2.  
Set Position-1, V, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming  
range.  
Connect the external 4-20mA programming current source to the ISOLATED ANALOG  
INTERFACE connector, with source at Pin-9 and return at Pin-25.  
3.  
4.  
5.  
Connect a jumper from Pin-25 to Pin-12.  
Connect a jumper from Pin-8 to Pin-20.  
Program the other parameters to the desired limit values: CURRENT PROGRAMMING  
INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.  
6.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.4.8  
4-20mA Current Source Programming of Output Current  
Setting up for 4-20mA programming of the output current is as follows:  
1.  
2.  
Set Position-2, I, of the INTFC SETUP switch to OFF (down) for 0-5VDC programming  
range.  
Connect the external 4-20mA programming current source to the ISOLATED ANALOG  
INTERFACE connector, with source at Pin-10 and return at Pin-13.  
2-10  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DLM 600W Series  
Isolated Remote Analog Interface Operation  
3.  
4.  
5.  
Connect a jumper from Pin-13 to Pin-12.  
Connect a jumper from Pin-11 to Pin-23.  
Program the other parameters to the desired limit values: VOLTAGE PROGRAMMING  
INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3, with respect to pin-12.  
6.  
Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG INTERFACE  
connector to Pin-15.  
2.5 EXTERNAL-OFF Control  
The EXTERNAL-OFF control input provides the same functionality as the OUTPUT switch on  
the front panel. When asserted, it will turn off the output converter, discharge the output  
capacitors with the downprogrammer, and reset the OVP and FAULT monitors. The signal  
could be configured to be either active-low or active-high with the INTFC SETUP switch on the  
rear panel.  
Set Position-6, /EXT-OFF, to the OFF (down) position to select the active-high logic level for  
asserting EXTERNAL-OFF. Set Position-6, /EXT-OFF, to the ON (up) position to select the  
active-low logic level for asserting EXTERNAL-OFF. The logic-high level could be produced  
with a voltage source within the range of 3-30VDC, and would be connected to Pin14, positive,  
and Pin-2, return. The circuit is SELV, and has electrical isolation from the output of the unit.  
2.6 Remote Monitoring  
Analog signals are available for monitoring the output voltage and current. These signals vary  
proportionally to the output parameters, and have user selectable ranges of 0-5VDC, 0-10VDC,  
or 4-20mA for an output change from zero to full scale. Refer to Table 2–4 for information on  
configuring the monitors.  
ISOLATED ANALOG  
INTERFACE Connections  
Output  
Monitor  
Signal  
INTFC SETUP Switch  
Signal  
Range  
Signal  
Pin-19  
Pin-19  
Pin-4  
Return  
Pin-2  
Pin-2  
Pin-6  
Pin-2  
Pin-2  
Pin-6  
Position  
4, VMON  
4, VMON  
4, VMON  
5, IMON  
5, IMON  
5, IMON  
Setting  
OFF (down)  
ON (up)  
Voltage  
Voltage  
Voltage  
Current  
Current  
Current  
0-5VDC  
0-10VDC  
4-20mA  
0-5VDC  
0-10VDC  
4-20mA  
OFF (down)  
OFF (down)  
ON (up)  
Pin-7  
Pin-7  
Pin-24  
OFF (down)  
Table 2–4. Remote Monitoring  
M51A Option  
2-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Isolated Remote Analog Interface Operation  
DLM 600W Series  
2.7 Remote Digital Status Signals  
Digital signals are available for remote monitoring the operational status of the unit. Refer to  
Table 2–5 for information on the characteristics of the signals.  
ISOLATED ANALOG  
INTERFACE Connections  
Logic Levels (with No  
Signal Output Current)  
Status  
Indicator  
Signal  
Output  
Resistance  
Signal  
Return  
Asserted  
Not Asserted  
VOLTAGE-  
MODE  
Pin-5  
Pin-6  
5V  
0V  
2kΩ  
OVP  
Pin-17  
Pin-18  
Pin-6  
Pin-6  
5V  
5V  
0V  
0V  
2kΩ  
2kΩ  
FAULT  
Table 2–5. Remote Digital Status Signals  
2-12  
M51A Option  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Fiesta Gas Grill EZT34545 B304 User Manual
First Alert Home Safety Product MMSKYE0709 User Manual
Fisher Price Model Vehicle 77982 User Manual
Fujitsu Flat Panel Television PDS4208W B PDS4209U B User Manual
Fusionbrands Home Theater System MS FR402 User Manual
Gardena Water Dispenser C 1060 profi User Manual
GE Double Oven JTP47SCSS User Manual
GE Microwave Oven JE1390 User Manual
Gemini Home Theater System CDM 3200 User Manual
GE Washer EWA4600 User Manual