PS-PRO - POWER CONDITIONER/SEQUENCER
20 amp plugs, see the information sheet“What Kind
Of Plug Is This, Anyway?” that accompanied this
RECOMMENDATIONS
In audio/video installations, we recommend that
power amps receive power last — plug them all into
Delay 3 or divide them into two groups and plug
one group through Delay 2 and the other through
Delay 3. Low level equipment such as mixers and
signal processors should use Delay 1. Equipment
incorporating clocks or timers such as VCR’s, or
equipment that must respond to wireless remote
actuation, should use the unswitched outlets. We
suggest keeping the front panel unswitched outlet
free for equipment that is only in use temporarily.
manual, or request a copy from Furman.
POWER SEQUENCING
FEATURES
The PS-PRO rear panel provides one unswitched
outlet pair and three switched outlet pairs. The
switched outlet pairs are labeled Delay 1, Delay 2,
and Delay 3. (The other pair of outlets on the rear
panel and an additional single outlet on the front
panel are unswitched.)
The overall capacity of the PS-PRO is 20 amps. This
refers to the combined steady-state current drawn
by all devices plugged into all of its nine outlets. If
this combined current level exceeds 20 amps at any
time, the circuit breaker will trip, cutting off power
to your rack. If this occurs, you must reduce the load
by unplugging one or more units from the PS-PRO.
Then push the white button on the circuit breaker
(on the front panel) in to reset it.
Here’s how the PS-PRO works: When an ON se-
quence is initiated, power is immediately applied
to the Delay 1 outlets. Power is then applied to
Delay 2 and Delay 3 outlets per the 1-60 second
total delay setting you choose with the front panel
Delay Adjust control.
The screwdriver-settable Delay Adjust controls the
total delay time between the Delay 2 and Delay 3
outlets. For example, if the Delay Adjust control is
set to 30 seconds, Delay 1 outlets will go on immedi-
ately, Delay 2 outlets will receive power 15 seconds
after Delay 1 outlets, and Delay 3 outlets will receive
power 15 seconds after Delay 2 outlets. Therefore
the total delay time is 30 seconds.
Although 20 amps is an absolute limit, the PS-PRO
will allow you to come as close as possible to using
the full 20 amps, because with power sequencing,
the risk of tripping the breaker is greatly reduced.
This is because the PS-PRO handles large but
temporary inrush currents in stages, rather than
simultaneously, allowing each stage to settle to its
steady-state current draw before the next stage is
powered.
The order is reversed on an OFF sequence. For
example, when an OFF sequence is initiated and
the Delay Adjust control is set at 60 seconds, Delay
3 outlets lose power immediately, Delay 2 outlets
lose power 30 seconds later and Delay 1 outlets lose
power 30 seconds after the Delay 2 outlets have
been shut off. The total delay time is 60 seconds.
Outlets and Plugs: The PS-PRO’s four rear panel
outlet pairs are standard 120V, 20A duplex types.
These outlets are widely spaced, to accommodate
one bulky plug-mounted“wall wart”power supply
in each without covering up an adjacent outlet.
The front panel outlet is limited to 15 amp use. The
PS-PRO also uses a 20 amp line cord, which can be
recognized by the perpendicular blades on the
plug. In 20 amp products, use of a plug of this type
is required for UL safety certification. It is compat-
ible with 20 amp outlets (such as the ones on the
PS-PRO’s rear panel.) For more information about
In the event of a power out, of course all equipment
plugged into a PS-PRO will lose power simultane-
ously. However, when power is restored, the delayed
outlet groups will again turn on in the usual delayed
sequence (if set to maintained on mode).
2
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
first so that the PS-PRO receives a stabilized voltage
to distribute.
POWER
CONDITIONING
FEATURES
MAINS WIRING FAULT
ANALYZER
The PS-PRO provides a very high degree of power
conditioning protection for your expensive and
delicate equipment.What sets Furman’s top-of-the-
line PRO-level protection apart from that offered
by other conditioners is the quantity, quality, and
configuration of its suppression devices. These in-
clude MOV’s, gas discharge tubes, fast-blow fuses,
and high voltage inductors and capacitors. This
unique combination can safely absorb and dissipate
large spikes from nearby lightning strikes and other
sources (up to 11,000 amps across any wiring mode
— line-neutral, line-ground, or neutral-ground), as
well as highly attenuate audible high frequency
noise. Clean, filtered power is provided at all 9
outlets, even the unswitched ones.
The PS-PRO also assists in analyzing any faults that
may occur in the AC mains wiring. Two green and
one red neon indicators light in a specific pattern for
normal wiring and in different patterns for various
faults. When the AC wiring is correct, both green
indicators will be lit, but not the red indicator. If
any other pattern of indicators is lit, a fault is pres-
ent. The chart next to the indicators identifies the
fault’s exact nature. Since any wiring fault presents
a potentially serious safety hazard, the assistance
of a qualified electrician should be obtained in cor-
recting the problem.
ON or OFF
SEQUENCING
The method of initiating an ON or OFF sequence
depends on whether the unit is to be controlled
locally or remotely. If remotely, it further depends
on the type of switch or switches used (momentary
or maintained).
The PS-PRO also includes special circuitry to detect
additional wiring faults, with several front panel LED
status indicators. The PS-PRO will even keep itself
from turning on, or will shut down under extreme
conditions, if the voltage falls below 80 volts or
rises above 140 volts.This feature is called“Extreme
Voltage Shutdown.”It is particularly valuable in the
entertainment industry, where equipment is fre-
quently moved to different venues, and accidental
connection to 220V is a real possibility. See pages
5-6 or more information on the various protection
features’indicator lights.
LOCAL CONTROL
For local control, an ON sequence is initiated
by turning the key switch to the ON position,
and an OFF sequence by turning the key switch
to REM or OFF position. The START ON-OFF
SEQUENCE pushbutton is not normally used in
local operation.
Despite its many protective features, you should be
aware that the PS-PRO does not compensate if the
AC line voltage itself is high or low (i.e., it does not
compensate for brownout conditions). If you fre-
quently move your rack to different locations, derive
power from generators, use long extension cords,
travel internationally, or are in an area particularly
prone to brownouts, you may benefit from the
use of one of Furman’s AC Line Voltage Regulators
in addition to the PS-PRO. If you do use a voltage
regulator, run the raw power line into the regulator
NOTE: If the PS-PRO is to be used under local control
only, and a jumper is installed on JMP1, and no
switch is connected to the PS-PRO’s terminal strip,
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
terminals are momentary tied together, the PS-PRO
will sequence ON or OFF.
then a jumper should be connected between the
REM and +12V terminals. Otherwise, turning the
front panel key switch to the REM position will turn
the PS-PRO ON.
JMP3 (MAINT OFF), when the REM and +12V
terminals are tied together, the PS-PRO will
sequence ON.
JMP4 (REM TO GND = ON), when the REM and
GND terminals are tied together, the PS-PRO will
sequence ON (Note: JMP1 must have a jumper
installed).
REMOTE CONTROL
When the PS-PRO’s front panel key lock switch is
in the REM position, it may be controlled by one or
more switches in remote locations. In the most basic
configuration, only two wires and an SPST switch
are needed to initiate an ON or OFF sequence. The
switch may be either a momentary or a maintained-
contact type, depending on a jumper setting inside
the PS-PRO. If an additional wire is used, an LED may
also be installed at the remote end to indicate that
the power is on.
JMP5 spare jumper holder.
MOMENTARY vs. MAINTAINED CONTACT
SWITCHING
An on-off switch of either kind may be used to
actuate the PS-PRO’s remote operation. Maintained
switches, such as most toggle switches and
push-on/push-off button switches, (including
the Furman RS-1 key lock switch), stay open until
switched, and then remain closed until switched
again. Momentary switches, usually pushbutton
types like the Furman RS-2 (which also provides
a locking key switch), are normally open and stay
closed only as long as the button is pressed.
PS-PRO units come factory-set for maintained
operation (jumper is installed on JMP1). They may
be easily converted to other operating modes by
moving jumper plug/plugs on the PS-PRO’s circuit
board. To do this, first disconnect the unit from
AC power. Remove the six screws that secure the
top cover and one screw from the front panel. Just
install the jumper plugs to the desired mode of
operation. Reattach the top cover.
Maintained switches are generally the most
convenient when there is only one remote
location. When more than one location is required,
momentary switches offer the advantage of a turn-
on or turn-off sequence which may be started from
any location.
MAINTAINED MODE
There are 3 maintained modes of operation:
REM to +12V = OFF (jumper plug installed on
JMP1, MAINT ON)
The PS-PRO main circuit board has 5 pairs of
terminals (PCB REV D and later) labeled as:
MAINTAINED MODE (continued)
JMP1 (Default) (MAINT ON) , when the REM and
+12V terminals are tied together, the PS-PRO will
sequence OFF.
(continued on page 7)
JMP2 (MOMENTARY), when the REM and +12V
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
FRONT PANEL
START ON/OFF SEQUENCE:This pushbutton switch
is used only when the key lock switch is in REM
position and the PS-PRO is in Momentary Mode. It
then acts the same as any other remote momentary
switch that may be connected to the rear panel ter-
minal strip. If the switched outlets are on, pushing
it begins an OFF sequence. If they are off, pushing
it begins an ON sequence. Do not use this switch
when in Maintained Mode.
PROTECTION OK: This LED is normally on when
the power to the PS-PRO’s outlets is switched on.
It monitors the integrity of the protection devices
and reports if the protection is compromised. If an
extremely large spike is encountered that exceeds
the PS-PRO’s capacity, the main group of input
protectors will blow an internal fuse, causing the
indicator to go out. If this LED is not lit when the
power switch is on, full protection is not function-
ing. Spike protection may still exist, but will have
a reduced capacity to absorb current. If this LED is
not lit, please contact the Furman Service Depart-
ment.
EXTREME VOLTAGE SHUTDOWN: This LED indica-
tor is normally off. It monitors a hazard common
in the entertainment industry—wiring faults—for
example, accidental connection to 220V. The PS-
PRO senses voltages that are so high or low that
operation would be impossible (under 80V or over
140V) and shuts the power down before damage
can occur. Upon initially applying power to the PS-
PRO, this indicator will be lit if the unit is receiving
below 80 volts or more than 140 volts, and power
will not be applied to the PS-PRO’s outlets. If the
unit has been operating with an acceptable input
voltage and then the voltage goes out of the ac-
ceptable range, the PS-PRO will shut down power
to all of its switched outlets simultaneously, without
observing the OFF delay cycle, and this LED will
begin flashing. When power returns to within the
acceptable range, the PS-PRO will observe its ON
delays as it returns power to its switched outlets,
and this LED will go out.
NOTE: If the mains power is below 80 volts and
has caused the PS-PRO to remove power from its
outlets, the PS-PRO will not restore power
to
its outlets until the mains voltage is more than 90
volts. If the mains power is above 140 volts and has
caused the PS-PRO to remove power from its out-
lets, the PS-PRO will not restore power to its outlets
until the mains voltage is less than 130 volts. The
reason for this is to prevent the power oscillating
on and off in marginal conditions.
DELAY ADJUST:This screwdriver-adjustable trimpot
allows you to set the total turn-on/turn-off delay
time from 1 to 60 seconds, as explained on page 6.
The trimpot adjusts both the on delay and off delay
times simultaneously.Turn the trimpot clockwise to
increase the on and off delay times; turn the trimpot
counterclockwise to decrease the delay times.
POWER STATUS (DELAY) LEDs: One green LED is pro-
vided for each of the three delay stages. Each LED
lights when power is applied to its corresponding
duplex outlet on the rear panel. All three LEDs then
remain steadily lit until power is removed. During
the power-down delay cycle, each LED goes off as
power to its corresponding outlet is removed. In
addition, the Delay 1 LED flashes if a remote switch
(or the stored state) is OFF.
MAINS WIRING INDICATORS: The PS-PRO assists in
analyzing any faults that may occur in the AC mains
wiring. Three neon indicators (two green and one
red) light in a specific pattern for normal wiring and
in different patterns for various faults. When the AC
wiring is correct, both green indicators will be lit. If
a fault is present, the chart immediately above the
neon indicator will identify the exact nature of the
5
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
fault. Since any wiring fault presents a potentially
serious safety hazard, the assistance of a qualified
electrician should be obtained in correcting the
problem.
NOTE: The Mains Wiring indicators and status LEDs
stay on even when the power switch is off. This
feature allows you to check the mains wiring before
powering up your equipment. These indicators are
designed for continuous, ongoing use. Like a clock,
they consume very little power.
CIRCUIT BREAKER: The overall capacity of the
PS-PRO is 20 amps. If the combined steady-state
current drawn by all devices plugged into all of its
nine outlets level exceeds 20 amps at any time, the
circuit breaker will trip, cutting off power to your
rack. If this occurs, you must reduce the load by
unplugging one or more units from the PS-PRO,
and reset it. You can reset the circuit breaker by
simply pressing in the button, which pops out when
tripped. However, because it is a thermal type, you
may have to wait a few moments after it trips for it
to cool down before it will allow you to reset it.
UNSWITCHED OUTLET: This convenient outlet pro-
vides power at all times when the PS-PRO is plugged
in and operating under normal power conditions.
UNSWITCHED OUTLETS:The PS-PRO rear panel pro-
vides clean, filtered power to this pair of unswitched
outlets, adjacent to the power cord.
SWITCHED (DELAYED) OUTLETS: The PS-PRO rear
panel provides three pairs of switched outlets,
widely spaced to allow use of equipment with
plug- in (wall wart) transformers. These switched
outlet pairs are labeled Delay 1, Delay 2 and Delay
ON/REM/OFF SWITCH:When turned to the ON posi-
tion, this key lock switch initiates an ON sequence,
applying power to the PS-PRO’s switched outlets.
When turned to the OFF position, it begins an OFF
sequence. In the REM position, the PS-PRO will
accept on/off commands from a remote switch or
switches that may be connected to the rear panel
terminals.
REAR PANEL
3. After the front panel switch is thrown to ON,
Delay 1 outlets receive power instantly, Delay 2
outlets receive power 1-30 seconds later and Delay
3 outlets receive power 130 seconds after Delay
2 outlets are powered. When thrown to OFF, the
sequence is reversed, with
needed to install a remote switch (see“Maintained
Mode”, page 6.) If a four-conductor cable is used, an
LED may be installed at the remote end to indicate
that the power is on.
Delay 3 losing power instantly, Delay 2 outlets los-
ing power 1-30 seconds later and Delay 1 outlets
losing power 1-30 seconds after Delay 2 outlets are
shut down. The delay intervals may be altered with
the screwdriver-adjustable Delay Adjust control
on the front panel.
TERMINAL STRIP: Allows one or more switches to be
connected to turn the PS-PRO on and off from a re-
mote location.Two, and sometimes three, wires are
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
The connection of the REM terminal to the +12V
terminal initiates an OFF sequence. Disconnecting
initiates an ON sequence. If the cable run is long, it
is recommended that the REM wire be tied to the
PS-PRO’s GND terminal during ON operation rather
than leaving it floating.This will require the use of a
third conductor and a double-throw switch.
MOMENTARY MODE
In Momentary Mode (jumper plug installed on
JMP2)
The PS-PRO has “memory”— it only needs a
momentary signal from the remote switch to
change its state from ON to OFF. When first plugged
in (or after power is lost and reapplied for any
reason) the stored state is OFF, and the DELAY 1
LED will flash. The unit will stay off until sequenced
ON by a momentary connection of the REM IN
terminal to +12V (the key switch must be in the
REM position). The sequence starts on the rising
edge of the signal.
REM to +12V = ON (jumper plug installed on JMP3,
MAINT OFF)
The connection of the REM terminal to the +12V
terminal initiates an ON sequence. Disconnecting
initiates an OFF sequence. If the cable run is long,
it is recommended that the REM wire be tied to the
PS-PRO’s GND terminal during OFF operation rather
than leaving it floating.
The front panel START ON-OFF SEQUENCE switch is
in parallel with, and functionally equivalent to, one
or more remote momentary switches that may be
connected to the terminal strip in the rear.
REM to GND = ON (jumper plugs installed on JMP1
and JMP4)
The connection of the REM terminal to the GND
terminal initiates an ON sequence. Disconnecting
initiates an OFF sequence.
The “memory” is independent of the key switch.
This means that even if the unit is sequenced off
by turning the key lock switch to OFF, when the
key lock switch is turned back to REM, the unit will
sequence back on — it will not be necessary to push
the START ON-OFF SEQUENCE button again. The
unit“remembers”its state until the incoming power
is lost, in which case it would default back to OFF.
NOTE: In Maintained Mode DO NOT USE the“START
ON-OFF SEQUENCE” switch on the front panel. If
you do you may activate an unintended sequence.
If a Furman RS-1 is the controlling switch contact
Furman’s Tech Support department for the proper
wiring diagrams.
MOMENTARY MODE
The front-panel key lock switch is not the primary
means of control in the momentary mode and
should normally be left in REM. It may be a useful
secondary means of control in the rare case of
REM to +12V = OFF
having several PS-PRO’s in parallel if there is some
reason to shut down one unit without affecting the
others. Because it is a maintained-contact switch,
7
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
RS-2 is the proper choice. Please contact Furman for
RS-2 wiring diagrams.
sync.This is the only way to re-sync units other than
disconnecting AC power to all units. Remember :
turning any key lock switch to OFF does not affect
the stored state, even though it will temporarily turn
the output of that unit off. If it is turned back to REM,
the PS-PRO will sequence back to ON because the
stored state is still ON.
MULTIPLE UNITS
You can use more than one PS-PRO to handle
loads that exceed 20 amps (16 amps PRO-E). To
control them remotely with one or more remote
switches, connect (in parallel) the REM, +12V (and
optionally GND) terminals of all units. Be sure that
the mode (momentary or maintained) of all units
is set the same. Set all key lock switches to REM.
Connect a single maintained switch or one or more
momentary switches to the nearest PS-PRO, as
discussed in the sections above. To avoid tripping
house breakers, the power input for each PS-PRO
should come from a separate 20 amp AC circuit. If
you are unsure whether your building’s wiring can
accommodate multiple fully-loaded PS-PRO’s or
PS-PROE’s, consult a qualified electrician.
STATUS TERMINAL
The STATUS terminal is an output that may be
used to illuminate an LED at the remote location
indicating that the power is available at the PS-
PRO’s outlets. If it is high (+5V), the unit is ON (or at
least in the process of sequencing ON); if low, the
unit is OFF (or sequencing OFF). Simply connect the
indicator LED between STATUS and ground (do not
use a series resistor). If the LED does not light when
the switch is in the ON position check the polarity
and reverse the LED leads if needed.
If multiple PS-PRO’s are controlled by one or more
momentary remote switches, all of the PS-PRO’s will
change state (from on to off or vice versa) on each
rising edge of the voltage on the REM IN terminal.
All remote switches or START ON-OFF SEQUENCE
pushbuttons on any unit’s front panel will toggle
all of the units. The key lock switches on each unit’s
front panel will turn off an individual unit that is
currently on without affecting the other units.
FLASHING DELAY 1 INDICATOR
The DELAY 1 LED on a PS-PRO flashes to indicate
that a remote switch is off or not connected. In
Maintained Mode (JMP1, MAINT ON’s jumper plug
is installed), this will only occur when the REM
terminal is tied to the +12V terminal. In Momentary
Mode, the LED flashes if the stored state is OFF.
Since the flashing function is only concerned with
the state of the remote switch (or switches), note
that it is possible for this LED to flash even when
the unit is ON. This could occur when the PS-PRO
is under local control (the key lock switch is in the
ON position). In this case, DELAY 1 would flash and
DELAY 2 and DELAY 3 would be steadily lit. This
serves as a warning that the unit will sequence OFF
if the key is turned to the REM position.
The STATUS lines work the same in either mode.
Each reflects the true state of the unit’s outlets and
is affected by both the “memorized” state and by
the key lock switch. A separate LED must be used
to indicate the status of each PS-PRO.
To address the unusual (hopefully rare) instance
when several PS-PRO’s in parallel fall out of sync,
resulting in some units turning on and others
turning off when a remote button is pushed, the
remote signal line has a special feature:
Holding the REM line high for at least 4 seconds
(whether by an actual remote switch or by any
unit’s START ON-OFF SEQUENCE switch) will force
all units to the OFF state, putting them back in
EFFECTS OF LIGHTNING
Lightningisanaturalphenomenonofoverwhelming
8
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
forcethatrepresentsthemostdifficultcircumstance
faced by a power protection product. The degree
of protection a PS-PRO can offer depends on the
intensity of the strike. If lightning strikes a distant
power line and causes a relatively small disturbance
to reach your location, the spike suppressors in the
PS-PRO will absorb the excess voltage invisibly
and harmlessly. However, if lightning strikes the
actual building where the PS-PRO is installed (or
somewhere very nearby), some damage may be
unavoidable due to the extremely high voltage
and current present. If this does occur, most likely
damage will be limited to the PS-PRO itself and will
affect only certain spike suppression components
(called varistors or MOV’s.) In this “suicide” mode,
the PS-PRO may sustain minor damage but
generally will protect all equipment plugged into
it from much more serious and costly damage
as long as that equipment is properly grounded.
Proper grounding requires the use of three-prong
AC cords, and that the building’s outlets are actually
grounded to earth as specified by the National
Electrical Code.
lightning should be a lightning arrestor installed on
your building’s electrical service entrance. If your
building does not have one, contact your local
power company or an electrical contractor to have
one installed.
THREE YEAR LIMITED
WARRANTY
The Furman PS-PRO is protected by a limited three
year warranty, covering defects in materials and
workmanship, provided that the registration card is
filled out and returned by the customer. Otherwise,
a one year warranty applies. Products must have a
proof of purchase from a Furman authorized dealer.
During this period, Furman will make any necessary
repairs without charge for parts or labor. Shipping
charges to the factory or repair station must be
prepaid by the owner; return shipping charges (via
UPS Ground) will be paid by Furman.
This warranty applies only to the original owner
and is not transferable. Also, it does not apply to
repairs done other than by the Furman factory or
Authorized Repair Stations.
This warranty shall be cancelable by Furman at its
sole discretion if the PS-PRO unit has been sub-
jected to physical abuse or has been modified in any
way without written authorization from Furman.
Furman’s liability under this warranty is limited to
repair or replacement of the defective unit.
Any PS-PRO known to have taken a direct lightning
hit should be checked by a qualified technician or
theFurmanfactorytodeterminewhethertheMOV’s
need replacement. (If the PS-PRO’s PROTECTION OK
indicator is not lit, there is definitely some damage.
Some spike suppression capability may still be
available by MOV Bank #2, but there is no guarantee
of this.) For optimum protection, you should not
rely exclusively on the PS-PRO to protect against a
direct lightning hit. The first line of defense against
Furman will not be responsible for incidental or
consequential damages resulting from the use or
misuse of its products. Some states do not allow the
exclusion of incidental or consequential damages,
so the above limitations may not apply to you. This
warranty gives you specific legal rights, and you
may also have other rights which vary from state
to state. Warranty claims should be accompanied
by a copy of the original purchase invoice showing
9
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO - POWER CONDITIONER/SEQUENCER
the purchase date (if a Warranty Registration Card
was mailed in at the time of purchase, this is not
necessary). Before returning any equipment for
repair, please read the following important infor-
mation on service.
SERVICE
Before returning any equipment for repair, please
be sure that it is adequately packed and cushioned
against damage in shipment, and that it is insured.
We suggest that you save the original packaging
and use it to ship the product for servicing. Also,
please enclose a note giving your name, address,
phone number and a description of the problem.
NOTE: All equipment being returned for repair
must have a Return Authorization (RA) Number.
To get an RA Number, please call the Furman Ser-
vice Department, (707) 763-1010, Ext. 120 or 121,
between 8 am and 5 pm U.S. Pacific Time. Please
display your RA Number prominently on the front
of all packages.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO SPECIFICATIONS
Current rating:
Input Voltage:
20 Amps (2400 Watts at 120 VAC)
85 to 264 VAC without damage
Mains Wiring analyzer: Detects one normal mode and five fault modes
Delay Intervals:
Total elapsed ON or OFF delay time adjustable
from 1-60 seconds, with a single trimpot:
ON sequence:
Delay 1 outlets go on immediately with switch.
Delays between outlets 1 and 2, and 2 and 3,
adjustable from 1-30 seconds each
OFF sequence:
Remote Switch:
Delay 3 outlets go off immediately with switch.
Delays between outlets 3 and 2, and 2 and 1,
same as ON delays
Screw terminals, 2 for switch, 2 additional for
optional LED (22 ga. minimum)
Spike Protection Modes:Line to neutral, neutral to ground, line to ground
Clamping Voltage, all modes: 200V peak
Response time:
1 nanosecond
Maximum surge current:
11,000 amps (8 x 20mS pulse)
Maximum spike energy: 550 joules total
Noise attenuation:
Differential mode: Greater than 40 dB; Common
mode: greater than 60 dB; both 1 to 200 MHz
Dimensions:
Weight:
1.75”H x 19”W x 10”D.
6 lbs (2.7 kg).
Construction:
Steel chassis, zinc chromate plating; .125”
brushed and black anodized aluminum front panel;
glass epoxy printed circuit boards.
Power Consumption:
Safety Agency Approvals:
Optional:
11 watts
UL, NRTL-C, C-UL, CE listed.
220/240V Versions (units with “E”suffix only) are
intended for use in countries with nominal 220 to
240 volt AC mains. Their rear panel outlets use
internationally accepted IEC-320 connectors.