PRIMERGY TX150 S4
System configurator and order-information guide
December 2005
Contents
Instructions
Configuration diagram
Configurator
0
System software
I
Basic unit
II Processor
III Memory
IV Graphics
V
Accessible drives
VI Hard disk drives
VII SCSI Controller
VIII Disk array
IX Communication/Network
X
System management options
XI Miscellaneous
XII Country specific options
Change report
PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4
Status 25.11.2005
Configuration diagram PRIMERGY TX150 S4
System unit ( I )
SIDE VIEW
FRONT VIEW
3 x 5.25"
Standard Power Supply
or
1. PSU
PS (I)
5.25" x 1.6"
5.25" x 1.6"
2. PSU
Redundant power supply option
5.25" x 1.6" CD / DVD drive
Modul 1
Modul 3
Pentium 4
5"x1" Floppy disk (option
Modul 2
Accessible drives ( V )
Modul 4
Processor ( II )
Extension slots
Memory ( III )
SCSI Controller ( VII )
Disk array ( VIII )
Hard disk drives ( VI )
Communication/Network ( IX )
PCIe x 1
SCSI 1"
SCSI 1"
SCSI 1"
SCSI 1"
PCIe x 4 (x8 Slot)
PCI short (5V) 32-Bit / 33MHz
PCI short (5V) 32-Bit / 33MHz
PCI-X 66 long (3,3V)
PCI-X 66 long (3,3V)
(Slot for Zero-Channel Controller)
PCI long (5V) 32-Bit / 33MHz
Key:
Included in basic unit
Option
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
3 of 18
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
Start PRIMERGY TX150 S4
SW Configurator IA32
PRIMERGY TX150 S4
Status 25.11.2005
with OEM-Software
without OEM-Software
for PRIMERGY Server
for PRIMERGY Server
Later use of OEM operating system
software is not allowed,
apart from few VMware
add-ons
VMware-Software
- VCMS VirtualCenter Management Server
- GSX Server and GSX Virtual Infrastructure Node
- P2V Assistant Enterprise Edition
For all SW products please refer to the corresponding software configurator accessible via
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
Microsoft - Software: **)
- Small Business Server 2003
- Windows Server 2003,
Web Edition (only English)
OES/NetWare-Software ***)
PRIMECLUSTER *)
- Clustering
- NetWare
- Load Balancing
Standard Edition
Enterprise Edition
- Additional loose
Linux - Software: **)
Client-Access-Licenses (CALs)
(not for Web Edition)
- SUSE Linux Enterprise Server
- SUSE Professional Linux
- Red Hat Enterprise Linux
SCO - Software: **)
- SCO OpenServer
- SCO UnixWare
CITRIX-Software für
Windows: W-MF
- Presentation Server
LoadBalancing
Additional User Licences
Manageability Software: V**)
- RemoteView Software
- RemoteView Service Board
- RemoteDeploy
Details eg. version numbers are published
in the separate SW-Configurator
*) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under
- Terminal Server Deploy
- vPMS 2005std
- Altiris Server Deployment
**) Pay attention to the release and ordering information in PRINCE -> Operating System
Backup-Software /
Application-Software: U
- ARCserve
***) Supply over distribution or procurement from FSC VP BC Software
- openSM2
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:
for partners:
Continue with PRIMERGY
HW configurator
Fujitsu Siemens Computers
4 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
Start PRIMERGY TX150 S4
SW Configurator EM64T
PRIMERGY TX150 S4
Status 25.11.2005
with OEM-Software
without OEM-Software
for PRIMERGY Server
for PRIMERGY Server
Later use of OEM operating system
software is not allowed,
apart from few VMware
add-ons
For all SW products please refer to the corresponding software configurator accessible via
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.
Microsoft - Software: W
Linux - Software: L *) **)
only
- Windows Server 2003,
x64 Standard Edition
only
- SuSE Linux Enterprise Server
EM64T
EM64T - Red Hat Enterprise Linux
x64 Enterprise Edition
- Additional loose
Client-Access-Lizenzen (CALs)
Details eg. version numbers are published
in the separate SW-Configurator
Manageability Software: V**)
- RemoteView Software
- RemoteView Service Board
- RemoteView Diagnosis
*) Pay attention to release information on datasheet under
**) Pay attention to release and order information in PRINCE -> Operating System
***) Supply over distribution or procurement from FSC VP BC Software
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:
for partners:
Continue with PRIMERGY
HW configurator
Fujitsu Siemens Computers
5 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
Start PRIMERGY TX150 S4
PRIMERGY TX150 S4
Status 25.11.2005
Section
Basic unit
I
System unit consisting of:
* Housing including standard power supply (no redundancy)
* Sliding screen with lock (only for floorstand version)
Systemboard with:
* 7 PCI slots:
1x PCIe x 1
1x PCIe x 4 (x8 Slot)
1x PCI-X 66 long (3,3V)
1x PCI-X 66 (3,3V) ZCR Slot
1x long / 2x short 32Bit / 33MHz (5V)
* 4 memory slots for up to 8GB (PC4200) registered DDR II RAM (ECC), max. 2GB modul per slot
* 1 drive bay 3.5" occupied by 1 floppy disk 1.44MB 1" height (optional)
* 3 Einbauplätze 5,25" für bedienbare Laufwerke
* 4 bays 1" for hot plug SCSI HD)
* ATI Range XL Graphic controller 8MB
* Intel Broadcom (5721) 10/100/1000 Mb/s on-board
* 1 x Fast-IDE (ATA) Controller on-board (for 1x 2 devices)
* 1-channel Ultra 320 SCSI Controller LSI 1020A on-board
with HW RAID IME (IME = Integrated Mirroring Enhanced)
Options:
* Hot plug PS or a second redundant hot plug PS version can be configured by ordering the
appropriate upgrade option
* LSI Zero Channel RAID option, simultaneous use of HD and Tape Drive possible
Cables:
1. IDE cable for CD/DVD
2. With SCSI variant wide LVD SCSI cable for connection of the HD backplane and two
accessible drives
PS/2 mouse (only for floorstand version)
ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView
External Interfaces:
2x RS-232-C (serial, 9 pins)
1x Centronics (parallel, 25 pins, EPP/ECP compatible)
1x keyboard (PS/2)
1x mouse (PS/2)
1x VGA (15 pins)
1x USB 2.0 on front and 2x USB 2.0 on rearside
1x LAN RJ45
Cables included in basic unit
Connections
Cable
PRIMERGY TX150 S4
1.
2.
Key:
IDE CD/DVD
¡
¥
¡
¡
68pins
68 or 50pins
IDE
¥
¥
¡
Backplane for 1x4
SCSI hard disks
¥
¥
¥
terminator
incl. terminator
A
Fujitsu Siemens Computers
6 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
A
PRIMERGY TX150 S4
Status 25.11.2005
Floorstand version SCSI basic unit
Pentium 4 processor, memory
19" Rack version SCSI basic unit (5 U)
Pentium 4 processor, memory
PD 820 2.8GHz/800MHz/2x1MB 512MB
PD 820 2.8GHz/800MHz/2x1MB 1GB
PD 820 2.8GHz/800MHz/2x1MB 2GB
S26361-K999-V136
S26361-K999-V146
S26361-K999-V156
PD 820 2.8GHz/800MHz/2x1MB 512MB
PD 820 2.8GHz/800MHz/2x1MB 1GB
PD 820 2.8GHz/800MHz/2x1MB 2GB
S26361-K999-V336
S26361-K999-V346
S26361-K999-V356
S26113-F483-E1
floorstand
versions
S26113-F483-E1
hot plug power supply upgrade option
With this option the basic units contains
1 hot plug power supply, 1 power
backplane and 1 dummy cover
replacing the standard power supply
(no redundancy !)
hot plug power supply upgrade option
With this option the basic units contains
1 hot plug power supply, 1 power
backplane and 1 dummy cover
replacing the standard power supply
(no redundancy !)
A second, redundant
power supply requires
an additional power
cord
(section XII)
max. 1x per system
max. 1x per system
S26113-F483-E11
S26113-F483-E11
2nd power supply module (PSU)
for redundancy
2nd power supply module (PSU)
for redundancy
occupies one bay for
hot plug power supply
max. 1x per system
occupies one bay for
hot plug power supply
max. 1x per system
For later conversion of basic units with standard power supply
to hot plug power supply, the following kit is available:
1.) hot plug PS upgrade kit, incl. 2 PS module:
Conversion standard into hot plug PS
2.) Supplementary power supply module
for redundancy or repair
S26113-F483-L1
S26113-F483-L11
B1
B2
Fujitsu Siemens Computers
7 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
B1
B2
PRIMERGY TX150 S4
Status 25.11.2005
PRIMERGY Floorstand
PRIMERGY Rack
PRIMECENTER- Rack
SNP:SY-F1647E301-P
"rack-mounting ex factory"
This service is to be ordered once
per installable server/storage
subsystem, in order to get the
server/storage subsystem
Installation ex works for one
server or subsystem
Hereby the rack will be delivered
completely pre-mounted and
all wired connections are tested
With racks 12U, 24U, 38U:
Systems and components
will be delivered installed in the rack
With racks 46U:
mounted into the PRIMERGY racks.
In case of the 46 U PRIMERGY rack,
this service has to be ordered,
to get the mounting kits and the
cables installed.
Systems and components
will be delivered separately
To be ordered only together with
a PRIMERGY-
PRIMECENTER rack
e.g.:SNP:SY-K614V10x-P
S26361-K826-V10x
refer configurator PC-rack
max. 1x per System
For later conversion of TX150 base unit floorstand into base unit rack the following kit is availible
1.) Conversion TX150S4 base unit floorstand into base unit rack
rack mount kit has to be ordered separately
S26361-F2618-L240
For (later) mounting in racks the following kits are available:
1.) PRIMERGY Classic-rack 42/23U adapter kit:
incl. cable carrier
S26361-F1331-L300
S26361-F2734-L32
S26361-F2734-L32
2.) PRIMERGY DC- / PC- rack mounting kit:
incl. DC- PC- bracket, cable managment
3.) PRIMERGY mounting kit for server racks
conforming to EIA standards EIA-310-D for 19" racks.
C
Fujitsu Siemens Computers
8 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
C
Section
Processor
II
Section
Memory
III
There are 2 memory banks with 2 DIMM slots each.
Single channel memory configuration allow maximum flexibility:
Additional memory can be configured as single memory modules.
Dual channel memory configurations for maximum performance:
For optimum performance memory has to be configured in pairs of memory modules with identical size.
S26361-F3000-E513
Main memory 512MB
DDR2 533/PC2-4200 ub ECC
consisting of one module
occupies one bank
S26361-F3000-E514
Main memory 1GB
S26361-F3000-E515
Main memory 2GB
DDR2 533/PC2-4200 ub ECC
consisting of one module
occupies one bank
DDR2 533/PC2-4200 ub ECC
consisting of one module
occupies one bank
3x
max. 3x per system
max. 3x per system
max. 3x per system
Section
Graphics
IV
ATI Rage XL (8MB)
D
Fujitsu Siemens Computers
9 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
D
Section
Accessible drives
V
There are 3x 5.25" bays for accessible drives:
- 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive
- 2 x 5.25" bays remaining, can be occupied by 2x accessible drives
Setup TX150 S4 by ServerStart is supported with following configurations:
no DVD, no CD:
remote installation only ( PXE service & DHCP server required)
built in CD/DVD:
UNC Network share reachable or USB Floppy or MemoryBird connected
One of the following USB devices must be used for integrating the drivers during installation
process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:
1) FDD USB (external): external USB FDD (USB cable included)
2) USB Memorybird: Memorybird 256 MB
Memorybird 1GB
S26391-F264-L226
S26391-F6046-L256
S26391-F6046-L24
S26361-F2575-E1
Floppy disk drive 1"
Connector: 26pin
incl. description (Ger/US)
1" * 3.5", anthracite bezel
max. 1x per system
SNP:SY-F2234E1-A
S26361-F3148-E1
DVD-ROM ATAPI
DVD-RW 16x super multi drive
all formats, DUAL/DL, DVD-RAM
only W2K, W3K and Linux
1.6 x 5.25", anthracite bezel
max. 1x per system
2x
incl. description (Ger/US)
1.6 x 5.25", anthracite bezel
max. 2x per system
S26361-F3157-E3
Tape drive LTO2HH Ultrium
200GB, 24MB/s, U160 SCSI
Connector: HD68
without cable
incl. description (Ger/US)
data and cleaning cartridge
1.6 * 5.25", anthracite bezel
max. 1x per system
S26361-F2849-E3
Tape drive VXA-2
80GB, 6MB/s, U2W SCSI
Connector: HD68
2x
without cable
incl. description (Ger/US)
data and cleaning catridge
1.6 x 5.25", anthracite bezel
max. 2x per system
S26361-F2848-E3
Tape drive DDS Gen5
S26361-F2848-E31 (only for OBDR)
DDS-G5 for One buttom dis. recov.
36GB, 3MB/s, U2W SCSI
Connector: HD68
without cable
incl. description (Ger/US)
data and cleaning catridge
1.6 x 5.25", anthracite bezel
max. 2x per system
E
Fujitsu Siemens Computers
10 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
E
PRIMERGY TX150 S4
Status 25.11.2005
S26361-F2814-E6
Backup drive and hard disk should run on separate channels
68-Pin Kit for accessible drives
Cable with Terminator
To connect acc. drives to
separate SCSI controller
max. 1x per system
If internal HDD's are connected at the RAID controller
(not IME/ZCR), then for internal accessible drives
the cable S26361-F2814-E6 must be ordered additionally!
Section
Hard Disk Drives
VI
S26361-F3121-E173
S26361-F3121-E114
S26361-F3121-E130
Hard disk 73GB in 1" carrier
10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins)
hot plug/hot replace tray
occupies 1" bay
Hard disk 146GB in 1" carrier
10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins)
hot plug/hot replace tray
occupies 1" bay
Hard disk 300GB in 1" carrier
10000rpm,<5,5ms, 8MB Cache
Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins)
hot plug/hot replace tray
occupies 1" bay
SCSI/RAID controller necessary
max. 4x per system
SCSI/RAID controller necessary
max. 4x per system
SCSI/RAID controller necessary
max. 4x per system
4x
S26361-F3121-E573
S26361-F3121-E514
Hard disk 73GB in 1" carrier
15.000rpm,<4ms, 8MB Cache
Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins)
hot plug/hot replace tray
occupies 1" bay
Hard disk 146GB in 1" carrier
15.000rpm,<4ms, 8MB Cache
Ultra 320 SCSI (320MB/s)
Interface: Wide SCA (80-pins)
hot plug/hot replace tray
occupies 1" bay
SCSI/ RAID controller necessary
max. 4x per system
SCSI/ RAID controller necessary
max. 4x per system
F
Fujitsu Siemens Computers
11 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
F
Section
SCSI-Controller
VII
All internal cables and adapters are included within the basic units and components respectively
Cabeling priorities:
internal HDs are cabled according to following priorities.
(Prio 1 - 3 ):
1.) For a configuration without any Disk Array Controller and without zero channel RAID
the onboard U320 Controller is connected to the internal HDs.
2.) For a configuration with a 2-channel Disk Array controller (without zero-channel RAID)
One channel will be connected with the internal hard disks.
The second channel is externally available.
internal backup devices are cabled according to following priorities.
(Prio 1 - 2 ):
1) For a configuration without additional SCSI controller
the onboard U320 controller is connected to internal backup devices
2) For a configuration with Adaptec SCSI Card 29160 S26361-F2399-E2
(without SCSI 160 controller S26361-F2644-E11)
this controller is connected to internal backup devices
A. on-board SCSI-controller for accessible drives and SCSI-HDs
1-channel Ultra 320 SCSI on-board controller; included as standard.
Example for IME with 3 data devices:
LSI Integrated Mirroring Enhanced (IME) is a RAID 1 implementation (no RAID 0 support). It can be operated also with an odd
number of hard disks (max. one RAID 1 Set). There are, depending on system, up to 6 hard disks, including a hot spare disk,
possible. Supportet are only the operating systems Windows2000/2003 as well as SuSE and RedHat Linux.
All internal cables and adapters for the basic unit and for components are included.
1x per TX150S4
T26139-Y3849-L1
Only SX10 Backup is released for the external
connection of the on-board SCSI controller
and the 29160.
External on-board SCSI Interface
Cable and external
connector interface (HD68)
occupies one connection panel
max. 1x per system for ext.
Cable sold separately not mounted in factory.
Use this cable only if on-board controller is not
used otherwise (eg. S26361-F2814-E6)
G
Fujitsu Siemens Computers
12 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
G
B. SCSI controller for internal backup drives
S26361-F2399-E2
SCSI 160 Controller
Adaptec SCSI Card 29160
1 channel: LVD + Fast/ Ultra (decoupl.)
LVD connect. for HD, without cable
Fast/Ultra connect. for acc. drives
64/66 PCI, min 180 mm
int: Fast 50-pin or Ultra HD68
+ LVD HD68; ext: HD68(LVD)
SW:
max. 1x per system
S26361-F2814-E6
68-Pin Kit for accessible drives
Cable with Terminator
To connect acc. drives to
separate SCSI controller
max. 1x per system
C. SCSI controller for external drives and peripheral devices
S26361-F2399-E1
Only SX10 Backup is for external
connection at the SCSI controller.
SCSI U160 controller
Adaptec SCSI Card 29160
1 channel: LVD + Fast/ Ultra (decoupl.)
LVD connect. for HD, without cable
Fast/Ultra connect. for acc. drives
64/66 PCI, min 180 mm
int: Fast 50 pol oder Ultra HD68
+ LVD HD68; ext: HD68(LVD)
SW:
max. 1x per system
Section
Disk Array
VIII
D. LSI - Controller
1-channel Ultra 320 SCSI on-board controller with LSI Integrated Mirroring (IME)
Standard SCSI-cabling of a PRIMERGY TX150 S4 basic unit with on-board controller
Ultra 320 SCSI controller is connected to the internal hard disks and internal backup devices,
if no additional HD/backup device controllers are configured.
1x per PRIMERGY TX150 S4
D. zero-channel RAID controller (320-0x) for internal Disk Array
and additional RAID controllers for internal / external Disk Array
S26361-F3085-E128
0-channel RAID controller
LSI
320-0x
128MB SDRAM ECC Cache
BBU optional
Zero channel RAID controller
LSI must be installed in the
blue marked bay.
in combination with on-board
U320 SCSI controller
without cable
64Bit/133MHz PCI-X controller
3.3V power supply & signaling
max. 1x per system
With zero channel RAID controller
the IME function is no longer
available.
S26361-F3085-E10
Cache Battery Backup Unit
max. 1x pro Controller
to be
continued
on next page
H
Fujitsu Siemens Computers
13 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
H
continued
on previous
E. 2-Kanal Ultra 320 SCSI Controller für Disk Array
page
S26361-F3090-E256
2-channel RAID Controller U320
LSI
320-2x
256MB SDRAM ECC Cache
default with TBBU
1x
plug: internal 2x HD68;
external: 2x VHDCI
without cable
64/133 PCI-X controller, 180mm
3.3V and 5V tolerant signaling
max. 1x per system
The fitting connection cables can be found in the configurator
of the external storage system and / or rack.
S26361-F2814-E6
Backup drive and HDD should run on separate channels.
68-Pin Kit for accessible drives
Cable with Terminator
To connect acc. drives to
separate SCSI controller
max. 1x per system
If internal HDD's are connected at the RAID controller
(not IME/ZCR), then for internal accessible drives
the cable S26361-F2814-E6 must be ordered additionally!
I
Fujitsu Siemens Computers
Enterprise Products - PRIMERGY Server
14 of 18
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
I
Section
Communication / Network
IX
Gigabit Ethernet Contr. on-board
The Intel LAN controllers 1000MT can be used
with the on-board controller in Teaming Mode
Broadcom
ext: for RJ 45-connector
SW: AFT, VLAN, Fast Channel
S26361-F3053-E1
S26361-F3142-E1
Gigabit Ethernet Contr. 1000TX
Eth. Ctrl 1x1Gbit PCI-X Pro/1000MT Cu
Intel PRO/1000 MT Server Adapter
Adapter Teaming Support
Gigabit Ethernet Contr. 1000TX
Eth. Ctrl 1x1Gbit PCI32 PRO/1000GT Cu
Intel Pro/1000 GT Adapter
PCI 32 (33/66MHz),
PCI-X (PCI64/133), min 165 mm
ext: for RJ45-plug, Cat 5
ext: for RJ45-plug, Cat 5
connection with Cat 5 cabling
SW: VLAN, Fast & Gbit Etherchannel
max. 4x per system
connection with Cat 5 cabling
SW: VLAN, Fast & Gbit Etherchannel
max. 4x per system
4x
S26361-F3011-E1
Gigabit Ethernet Contr dual 1000TX
Intel Pro/1000MT dual Server Adapter
Adapter Teaming Support
PCI-X (PCI64/133), min 163 mm
ext: for RJ45-plug, Cat 5
connection with Cat 5 cabling
SW: VLAN, Fast Etherchannel
max. 2x per system
S26361-F1809-E2
ISDN SO Controller PCI
Eicon Diva Server BRI-2M 2.0
Incl. SO-connector
occu. short PCI slot min. 170 mm
SO-Interface
max. 2x per system
J
Fujitsu Siemens Computers
15 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
J
Section
System management options
X
S26361-F2425-E103
RSB S2 LP 3HU
RemoteView Service Board S2
Low Profile Version with 3 U bracket
for one standard PCI-slot
incl. cables and RV SW
max. 1x per system
S26361-F2425-E305
RSB S2 LP external power supply
RemoteView Service Board S2
low profile external power supply
including power cable
with Euro- and Euro socket connector
Section
Miscellaneous
XI
S26361-F1652-L4
In connection with rack configurations
Modem external 56kbps (V.90)
MultiTech
the install variant of the modem
(S26361-F1652-E4) has to be ordered
(see rack configurator)
MT5643ZBA-Global
international approval
incl. 2m Telephon cord RJ11/RJ11
Adapter Plug RJ11/TAE
Serial Interface cable DB25m / DB9f
AC-Adapter w. German Power Cord
occupies one COM port
max. 1x per system
K
Fujitsu Siemens Computers
16 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
K
Section
Country specific / rack specific options
XII
A country specific power cord has to be ordered for all floorstand versions:
- once per basic unit and an additional second cable
- if an second hot plug, redundant power supply modul is ordered.
PRIMERGY TX150 S4 Floorstand
PRIMERGY TX150 S4 Rack
Power cord for following countries:
1,8 m, grey
Country specific power cords are not
required for rack versions, except for USA
&Canada. Power cords are shipped in a rack
version with inlet connector for non-heating
apparatus. (1x with Standard PSU,
T26139-Y1740-E10
D, A, B, F, NL, FIN, S, N, E, P, RUS, TR
max. T26139-Y1742-E10
USA, Canada
Switzerland
2 x
T26139-Y1743-E10
T26139-Y1744-E10
T26139-Y1745-E10
T26139-Y1746-E10
T26139-Y3850-E10
UK, Ireland
2x with hot plug upgrade)
Italy
Denmark
T26139-Y1742-E10
USA, Canada
No power cord as order option
For shipments to USA&Canada, you have to order
one power cord (1,8m, grey) per power supply.
Attention: For connection of a monitor
to the system an additional country
specific power cord has to be
ordered as option.
Power cord for optional monitor connection for the following countries:
1.8m, grey
T26139-Y1740-L10
T26139-Y1742-L10
T26139-Y1743-L10
T26139-Y1744-L10
T26139-Y1745-L10
T26139-Y1746-L10
D, A, B, F, NL, FIN, N, S, E, P, RUS, TR
USA, Canada
Switzerland
UK, IR
Italy
Denmark
Powercord 3-way splitter 1M to 3F
0.78m, grey
T26139-Y3692-L1
Adapter for the connection of up to 3 PS-modules or up to
2 PS-modules and one monitor to the mains connection.
Both, standard and hot plug power supplies, are supported.
Other options and Peripherals
For other options refer to the section "Product-specific options
These options are supplied loose with the shipment.
For suitable peripherals for this product refer to the section "Peripherals/communication".
Option for Floorstand
keyboards for floorstand versions for following countries:
S26381-K397-E110
S26381-K397-E120
S26381-K397-E140
S26381-K397-E155
S26381-K397-E165
S26381-K397-E180
S26381-K397-E185
USA / international
Germany
France
Sweden / Finland
United Kingdom
Spain
Italy
End PRIMERGY TX150 S4
Fujitsu Siemens Computers
17 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
System configurator and order-information guide
PRIMERGY TX150 S4 Status 25.11.2005
Cange Report
Date
Order number
Changes
2005-11-23 S26361-F1809-E2
2005-03-31
ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available
First release
Fujitsu Siemens Computers
18 of 18
Enterprise Products - PRIMERGY Server
Download from Www.Somanuals.com. All Manuals Search And Download.
|