P3PC-1422-03EN
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTENTS
■ Safety Precautions ................................................................ v
fi-5900C Image Scanner Getting Started
i
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Thank you for purchasing the fi-5900C Duplex Color
Scanner.
This document describes how to use fi-5900C and basic
operation methods. Before you start using fi-5900C be
sure to thoroughly read this manual to ensure correct
use.
•The use of a shielded interface cable
is required to comply with the Class B
limits of Part 15 of FCC rules. The
length of the SCSI interface cable
must be 1.5 meters (5 feet) or less..
NOTICE
•The length of the AC cable must be 3
meters (10 feet) or less.
The "Operator’s Guide" stored on the Setup CD-ROM
provides useful and detailed information on Operations
when you would like to use advanced features, Daily
Care for maintenance of the scanner, and Replacing
Consumables to maintain conditions for smooth scan-
ning. Please also read the Operator’s Guide for further
information.
Canadian DOC Regulations
This digital apparatus does not exceed the Class B
limit for radio noise emissions from digital
apparatus set out in the Radio interference
Regulations of the Canadian Department of
Communications.
■ Regulatory Information
This Class B digital apparatus complies with
Canadian ICES-003.
FCC declaration
Le présent appareil numérique n'émet pas de
parasites radioélectriques dépassant les limites
applicables aux appareils numériques de la classe
B et prescrites dans le Règlement sur le brouillage
radioélectrique dictées par le Ministère des
Communications du Canada.
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment generates,
uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not
occur in a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference by
one or more of the following measures:
Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
Bescheimigung des Herstellers /
Importeurs
Für den fi-5900C wird folgendes bescheinigt:
•In Übereinsstimmung mit den Bestimmungen
der EN45014(CE) funkentstört
•Maschinenlärminformationsverordnung
3.GPSGV: Der höchste Schalldruckpegel beträgt
70 dB (A) oder weniger, gemäß EN ISO 7779.
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment
and receiver.
®
International ENERGY STAR Program
•Connect the equipment into an outlet on a circuit
different from that to which the receiver is
located.
As an ENERGY STAR®
Partner, PFU LIMITED
has determined that this
product meets the
•Consult your dealer or an experienced radio/TV
technician.
ENERGY STAR®
guidelines for energy
efficiency.
The International
ENERGY STAR® Office
FCC warning: Changes or modifications not
expressly approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
Equipment Program is an international program
that promotes energy saving through the
penetration of energy efficient computers and
other office equipment. The program backs the
development and dissemination of products with
functions that effectively reduce energy
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
consumption. It is an open system in which
business proprietors can participate voluntarily.
The targeted products are office equipment such
as computers, monitors, printers, facsimiles,
copiers, scanners, and multifunction devices.
Their standards and logos are uniform among
participating nations.
About the use of mercury
Lamp(s) inside this product contain
mercury and must be recycled or
disposed of according to local, state, or
federal laws.
g
H
To avoid unexpected injuries;
•Do not put the substance contained in the lamp
■ Note, Liability
in your mouth as it has mercury.
•Do not breathe the chemical liquid contained in
READ ALL OF THIS MANUAL CAREFULLY
BEFORE USING THIS PRODUCT. IF THIS
PRODUCT IS NOT USED CORRECTLY,
UNEXPECTED INJURY MAY BE CAUSED TO
USERS OR BYSTANDERS.
the scanner lamps.
•Do not incinerate, crush, or shred the lamps or
scanner parts.
Also, keep this manual in a safe place so that it
can be easily referred to during use of this
product.
Trademarks
Microsoft, Windows, and Windows NT are
registered trademarks of Microsoft Corporation in
the United States and/or other countries.
ISIS and QuickScan are trademarks or
registered trademarks of EMC Corporation
in the United States.
While all efforts have been made to ensure the
accuracy of all information in this manual, PFU
assumes no liability to any party for any damage
caused by errors or omissions or by statements of
any kind in this manual, its updates or
Adobe, the Adobe logo, and Acrobat are either
registered trademarks of Adobe Systems
Incorporated in the United States and/or other
countries.
Other product names are the trademarks or
registered trademarks of the respective companies.
supplements, whether such errors are omissions or
statements resulting from negligence, accidents,
or any other cause. PFU further assumes no
liability arising from the application or use of any
product or system described herein; nor any
liability for incidental or consequential damages
arising from the use of this manual. PFU disclaims
all warranties regarding the information contained
herein, whether expressed, implied, or statutory.
How Trademarks Are Indicated In
This Manual
Use in High-safety Applications
References to operating systems (OS) are
indicated as follows:
This product has been designed and manufactured
on the assumption that it will be used in office,
personal, domestic, regular industrial, and
general-purpose applications. It has not been
designed and manufactured for use in applications
(simply called "high-safety applications" from
here on) that directly involve danger to life and
health when a high degree of safety is required,
for example, in the control of nuclear reactions at
nuclear power facilities, automatic flight control
of aircraft, air traffic control, operation control in
mass-transport systems, medical equipment for
sustaining life, and missile firing control in
weapons systems, and when provisionally the
safety in question is not ensured. The user should
use this product with adopting measures for
ensuring safety in such high-safety applications.
PFU LIMITED assumes no liability whatsoever
for damages arising from use of this product by
the user in high-safety applications, and for any
claims or compensation for damages by the user
or a third party.
®
®
Microsoft Windows 95
operating system
Windows 95
®
®
Microsoft Windows 98 /98 Second
Edition operating system.
Windows
98/98SE
®
®
Windows
Me
Microsoft Windows
Millennium Edition operating system.
®
®
Microsoft Windows NT 4.0
Server operating system,
Windows
NT 4.0
®
®
Microsoft Windows NT 4.0
Workstation operating system.
®
®
Windows
2000
Microsoft Windows 2000
Professional operating system.
®
®
Microsoft Windows XP
Windows XP
Professional operating system,
®
®
Microsoft Windows XP
Home Edition operating system.
fi-5900C Image Scanner Getting Started
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Where there is no distinction between the different
versions of the above operating system, the
general term "Windows " is used.
Symbols Used In This Manual
This symbol alerts operators to particularly
important information. Be sure to read this
information.
ATTENTION
®
®
Adobe Acrobat
Adobe Acrobat
All the descriptions in this manual assume the
usage of Adobe Acrobat bundled with this
product. However, Adobe Acrobat may be
upgraded without notice. If the descriptions differ
from the screens actually displayed, refer to the
Acrobat’s “Help”.
This symbol alerts operators to helpful
advice regarding operation.
HINT
Manufacturer
A TRIANGLE symbol indicates that special care
and attention is required.
PFU LIMITED
The drawing inside the triangle shows the
specific caution.
International Sales Dept., Imaging Business
Division, Products Group
Solid Square East Tower, 580 Horikawa-cho,
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,
Japan
A CIRCLE with a diagonal line inside shows
action which users may not perform.
The drawing inside or under the circle shows the
specific action that is not allowed.
Phone : (81-44) 540-4538
Outline characters on a colored background
show instructions users should follow.
All Rights Reserved, Copyright© PFU LIMITED 2006
It may also include the drawing that shows the
specific instruction.
R
About Maintenance
The user must not perform repairs on this scanner.
Contact the store where you purchased the scanner
or an authorized FUJITSU Image Scanner service
provider to make repairs to this product.
Warning Label
The glass surface inside the ADF becomes hot
during the operation. Be careful not to touch the
glass surface inside the ADF.
Warning Indications Used In This
Manual
Do NOT remove, stain or scratch the
ATTENTION
warning labels from the scanner.
This indication alerts operators to an
operation that, if not strictly
observed, may result in severe injury
or death.
Screen Examples In This Manual
This indication alerts operators to an
operation that, if not strictly
observed, may result in safety
hazards to personnel or damage to
equipment.
The screen examples in this manual are subject to
change without notice in the interest of product
improvement. If the actual displayed screen
differs from the screen examples in this manual,
operate by following the actual displayed screen
while referring to the User's Manual of the scanner
application you are using.
The screenshots in this manual were captured
from FUJITSU TWAIN32 scanner driver,
ScandAll 21 Image Capturing Utility Software,
FUJITSU ISIS scanner driver, QuickScan Pro™
image capturing software and Adobe® Acrobat®.
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Safety Precautions
Turn the scanner OFF if it is damaged.
If the scanner is damaged for any reason, turn
off the scanner and unplug the AD cable before
contacting the store you purchased the
scanner.
Do not damage the AC cable.
Do not put liquids inside the scanner.
A damaged AC cable may cause fire or electric
Do not insert or drop metal objects in to the
scanner. Do not scan wet documents or
documents with paper clips or staples. Do not
splash or allow the scanner to get wet.
shock. Do not place heavy objects on AC
cables, or pull, bend, twist, heat, damage or
modify AC cables.
Do not use damaged AC cables or power
plugs, or install any cables or power plugs to
loose wall sockets.
If foreign objects (water, small metal objects,
liquids, etc.) get inside the scanner, immediately
turn off the scanner and disconnect the power
plug from the power outlet, then contact the store
where you bought the scanner or the
Maintenance Service Center. Pay particular
attention to this warning in households where
there are small children.
Use only specified AC cables and
connector cables
Use only specified AC cables and connector
cables. Failure to use the correct cables might
cause electric shock and/or equipment failure.
Please don’t use the AC cable provided with
this scanner for other devices, since this might
cause equipment failure and other troubles or
an electric shock.
Do not touch the inside of the scanner
unless necessary.
Do not take apart or modify the scanner. The
inside of the scanner contains high-voltage
components. Touching these components might
cause fire or electric shock.
Use this scanner only at the indicated
power voltage. Do not connect to multiple-
power strips.
Do not use the scanner if there is a strange
odor.
Use this scanner only at the indicated power
voltage and current. Improper power voltage
and current might cause fire or electric shock.
Do not connect to multiple-power strips.
If you detect excessive heat coming from the
device or detect other problems such as smoke,
strange smells or noises, disconnect immediately
the power plug in order to turn out the scanner.
Make sure that any smoke coming from it has
stopped, before contacting the store where you
bought the scanner or an authorized FUJITSU
scanner service provider.
Do not touch the AC cable with wet hands.
Do not touch the power plug with wet hands.
Doing so might cause electric shock.
Wipe any dust from the power plug.
Wipe off any dust from metal parts on the
power plug or metal fittings with a soft, dry
cloth. Accumulated dust might cause fire or
electric shock.
Do not install the device in locations that
has oil smoke, steam, humidity, and dust.
Do not install the scanner in locations subject
to oil smoke, steam, humidity, and dust. Doing
so might cause a fire or electric shock.
fi-5900C Image Scanner Getting Started
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Before moving the scanner, disconnect the
power plug from the power outlet.
Do not move the scanner with the power and
interface cables connected as this might
damage the cables, causing fire, electric shock
or injuries. Before moving the scanner, be sure
to disconnect the power plug from the power
outlet, and all other data cables. Make sure that
the floor is free of any obstruction.
Do not install the scanner on unstable
surfaces.
Make sure that the scanner is installed on a
flat, level surface and that none of its parts
extend beyond the surface top, such as a desk
or table. Do not install the scanner on
unstable surfaces. Install the scanner on a level
surface that is free of vibration to prevent it
from falling.
Protect the scanner from static electricity.
Install the scanner on a strong surface that will
support the weight of the scanner and other
devices.
Install the scanner away from strong magnetic
fields and other sources of electronic noise.
Also, protect the scanner from any static
electricity as this might cause the scanner to
malfunction.
Do not block the ventilation ports.
Do not block the ventilation ports. Blocking the
ventilation ports generates heat inside of
scanner, which may results in fire or scanner
failure.
Do not use aerosol sprays near the
scanner.
Do not use aerosol sprays to clean the
scanner. Aerosol sprays cause dirt and dust to
enter the scanner, resulting scanner failure and
malfunction.
Do not place heavy objects or stand on top
of the scanner.
Do not place heavy objects on the scanner or
use the scanner's surface top to perform other
work. Improper installation might cause injuries
and equipment failure.
Disconnect the power plug from the power
outlet when the scanner is not used for a
long period of time.
When the scanner is not going to be used for a
long period of time, be sure to disconnect the
power plug from the power outlet for safety.
Firmly insert the power plug.
Firmly insert the power plug as far it can go into
the power outlet.
Do not install the scanner in the direct
sunlight.
Avoid any contact when scanner is in use.
Do not install the scanner under direct sunlight
or near heating apparatus. Doing so might
cause excessive heat to build up inside the
scanner, which can cause scanner trouble or
even fire. Install the scanner in a well-ventilated
location.
Avoid touching any scanner mechanism during
scanning since this may cause injuries.
Do not use the scanner immediately after
moving it from a cold place into a warm
room.
Do not carry the scanner alone.
When transporting the scanner, never carry it
alone. The scanner is heavy.
Do not use the device immediately after
moving it from a cold place into a warm room.
This may cause condensation, which might
lead to scanning errors. Let the device dry
about one or two hours before you use it.
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter1 PREPARING THE SCANNER
1.1 Checking the Contents of
No.
Name
Function
the Scanner Package
9
ADF cover
open button
Button used to open the ADF
When you unpack the scanner package, make sure that
the package contains all the parts on the list included in
the package.
If any parts are missing or defective, contact your scan-
ner dealer or an authorized FUJITSU scanner service
provider. Handle the scanner and accessories with care.
10
11
Pre-imprinter
cover
For the Pre-Imprinter option
ADF
The documents loaded onto the
Hopper will be fed sheet by sheet
for scanning.
(Automatic
document
feeder)
12
13
14
Hopper
extension
Pulls the Hopper extension out for
loading long documents.
1.2 Names of Parts
Hopper
Documents to be scanned are
loaded onto the Hopper.
This section describes the names of parts.
Hopper side
guides
Sheet Guides used to make sure
that the paper to be scanned is fed
into the scanner straight, avoiding
skew.
■ Front side
15
Power button
Switches the scanner ON&OFF.
2
3
4
5
6
1
■ Rear side
7
8
1
2
9
10
15
3
5
4
7
8
6
11
12
No.
Name
Function
14
13
1
Main power
switch
For switching the power support
ON/OFF.
No.
Name
Function
2
3
Power inlet
For connecting the AC cable.
1
Stopper
Prevents ejected documents from
dropping off the scanner.
SCSI ID Switch
Sets the scanner’s SCSI ID with
this switch.
2
3
Stacker side
guide
4
5
6
SCSI connector
USB connector
For aligning ejected documents to
a certain width.
For connecting the SCSI cable.
For connecting the USB cable.
Top cover
Cover to access the consumables
storage box and Post Imprinter
option (sold separately).
Extended mem-
ory slot
For connecting an extension
memory (sold separately).
7
8
VRS slot
The VRS board has been
installed
4
5
Stacker
Ejector
Area where ejected paper collects
after scanning.
Extended slot
A spare slot for an option board
For ejecting the documents after
scanning.
6
7
Operator
panel
For operating the scanner.
Stacker
extension
For scanning long documents. Pull
the extension out according to the
document’s length.
8
ADF cover
Opens the cover for cleaning the
inner parts of the ADF or for
replacing consumables.
fi-5900C Image Scanner Getting Started
1
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Removable Parts
1.3 Operator panel
The operator panel is located on the right side of the
scanner. The panel consists of a Function Number Dis-
play, buttons and a LED.
Function number display
1
Function
Hopper Height
Ho
pp
er
He
ihgt
T
h
i
n
T
h
ic
k
Paper Thickness
Thin
Thick
Sendto
Scan
No.
Name
Description
1
Document
smoother
Attached when the stacker posi-
tion is set to align the ejected doc-
ument by the leading edge, or
when scanning documents with
different widths.
Name
Function
Shows the status of the scanner.
Function
For details, refer to "Indications on
Hopper Height
Use these buttons to adjust the height
of the Hopper to the Upper/Middle/
Lower Positions.
2
3
The hopper moves automatically to
the right position after giving a scan-
ning command. However, this may
cause a delay before the actual scan-
ning starts. To avoid unnecessary
waiting time, it is recommended to set
the hopper height prior to scanning.
The approximate loading capacities
are as follows (* these numbers differ
depending on the document thickness)
Upper: 100 sheets
4
5
Middle: 300 sheets
Lower: 500 sheets
No.
Name
Description
Paper Thickness
Use these buttons to adjust the paper
thickness for the papers to be scanned.
When picking errors or paper jams
occur:
Thin
Thick
2
Pick rollers
Rollers that pick the paper from
the hopper into the ADF. This is a
consumable item.
Press the
When multifeed occurs:
(Thin) button.
3
4
5
Separator
rollers
Rollers used to help separate the
paper as the feeding begins. This
is a consumable item.
Press the
(Thick) button.
Brake roller
Pad
Roller used to help separate the
paper as the feeding begins. This
is a consumable item.
(Normally no need to change from the
default setting)
Use this button to start linked applica-
tions (*About the settings, refer to the
"fi-5900C Operator’s Guide" on the
Setup CD-ROM).
Send to
Scan
Separation Pad used to help sepa-
rate the paper as the feeding
begins. This is a consumable
item.
Use this button to turn the power ON/
OFF.
When the power is turned on, the but-
ton is illuminated in blue.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Indications on the Function
Operator Panel Overlays are available in
French, German, Italian, Spanish, Chinese,
Russian and Korean. To change the over-
lay, open the plastic cover.
Number Display
HINT
The following shows the indications on the Function
Number Display.
No.
Descriptions
Lights only one time upon turning on the scanner.
Indicates that the scanner has been turned ON
and is being initialized.
Thin
S
end
to
S
can
Indicates that initialization has been completed
successfully.
This status is called "Ready Status".
Indicates that a temporary error (that users can
solve) has occurred during the initialization or
scanning of documents.
"U" and an error number (1, 2, 4, 6, 8) are dis-
played alternately.
To return the scanner to the ready status ("1"),
press the "Scan" or "Send to" button while the
error is indicated.
Indicates that a device alarm (that users can not
solve) has occurred during the initialization or
scanning of documents.
"E" and an alarm number (0, 2 to 9, and A, c, d,
F, 10 to 12, 15 to 19, 1A) are indicated alter-
nately.
To return the scanner to the ready status ("1"),
press "Scan" or "Send to" button.
If this alarm occurs, turn the power off and then
on again. If the alarm is indicated after turning on
the power again, contact your service engineer.
fi-5900C Image Scanner Getting Started
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter2
INSTALLATION OF THE SCANNER
2.1 Installing the Scanner
2.2 Connecting the Scanner to
Your PC
1. Place the scanner at its installation site.
When running Windows 95 or Windows NT 4.0, con-
nect the scanner using the SCSI interface.
When running Windows 98, Windows Me, Windows
2000, or Windows XP, connect either using the USB or
SCSI interface.
For details on the scanner's dimensions and
required installation space, refer to the fi-5900C
Operator’s Guide, chapter "10. Scanner Specifi-
cations".
•
•
The scanner weight is 50 kg (110 lb).
Make sure two persons are available
when moving the scanner.
ATTENTION
This scanner is provided with two inter-
ATTENTION
faces: Ultra SCSI and USB 2.0 /1.1. Con-
nect only one of the USB or SCSI cable.
Windows 95 and Windows NT 4.0 do not
support USB interface.
When carrying the scanner, only grip the
bottom side.
2. Connect the AC cable to the Power inlet of the
scanner and plug it into an outlet.
■ Connecting the USB Interface
1. Connect the USB cable to the USB connector.
2. Connect the other end of the USB cable to
your PC.
•
•
Be sure to use the USB cable which
comes with this scanner. Correct opera-
tion with commercially available cables
is not guaranteed.
ATTENTION
Use only the power cable provided by the
manufacturer.
ATTENTION
When connecting to a USB hub, use the
first stage USB hub that is closest to the
computer. If you use the second or later
hub stages, the scanner may not oper-
ate correctly.
•
If you connect the scanner with USB 2.0,
it is required that the USB port and Hub
are compliant with USB 2.0. The scan-
ning speed may slow down if it is con-
nected with USB1.1.
The Function Number Display and the LED
may flash for an instant when plugging the
AC cable into the outlet. This is not a mal-
function.
HINT
4
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Press the "I" side of the main power switch to
turn on the scanner.
3. Set the SCSI ID using the SCSI ID switch on
the back of the scanner.
OFF
ON
The SCSI ID is initially set to "5" at the factory.
If the SCSI ID of another SCSI device is set to the
same ID, either change the scanner's SCSI ID or
SCSI ID of the other SCSI device.
■ Connecting the SCSI interface
When using the scanner with a SCSI interface, the fol-
lowing SCSI cable and SCSI card must be purchased.
ID No.
0 to 7
8, 9
Description
Can be set as the ID
• SCSI cable:
Works with the factory default value
(SCSI ID = 5).
Use a SCSI cable whose connector on the scan-
ner side is the 68-pin high-density shielded-type
and whose connector on the PC side fits the con-
nector of the SCSI card to use.
When the scanner is turned on, the SCSI ID set is
enabled.
It is recommended to use a cable of length 1.5m
or shorter.
4. Press the "I" side of the main power switch to
turn on the scanner.
• SCSI card
Find the recommended SCSI card information
on the Fujitsu web site (FAQ).
computing/peripheral/scanners/scsi/
OFF
ON
•
•
When connecting the SCSI cable, turn
the scanner off. Be sure to connect the
SCSI cable first, and then turn on the
power of the scanner and PC.
ATTENTION
■ When using VRS
In a SCSI daisy chain configuration,
connect the scanner so that it is the ter-
minated device.
When using the Kofax® VRS, you need to connect it to
the exclusive VRS board with either the USB cable or
SCSI cable.
1. Insert the SCSI cable into the interface connec-
tor of the scanner until both sides click.
1. If you use the USB cable, insert it into the inter-
face connector (1) shown below.
If you use the SCSI cable, insert it into the
interface connector (2) shown below.
SCSI ID Switch
VRS board
2. Connect the other end of the cable to your PC.
2
1
Be careful not to bend the pins of the SCSI
cable when connecting to the scanner.
ATTENTION
2. Connect the other end of the cable to your PC.
fi-5900C Image Scanner Getting Started
5
Download from Www.Somanuals.com. All Manuals Search And Download.
3. When using the SCSI cable, set the SCSI ID
using the SCSI ID switch on the back of the
scanner.
The following applications also come with fi-5900C.
They will provide you more convenient and advanced
usage.
(Refer to step 3 in "Connecting the SCSI interface"
• Error Recovery Guide
The Error Recovery Guide is a software that dis-
plays troubleshooting information on screen if
any scanner error occurs.
4. Press the "I" side of the main power switch to
turn on the scanner.
• Adobe Acrobat
De facto standard software for generating and
manipulating PDF format electronic document.
The following sections describe installation of each
driver and application.
OFF
ON
For FUJITSU TWAIN32 Scanner Driver
VRS (VirtualReScan®) is the image process-
ing software manufactured by Kofax Image
Products, Inc.
It enables to correct image defects, such as
document skew when scanned by the scan-
ner, or "jitter" generated by colors or half-tone
dot meshing, and so on.
You need to install the software in the VRS
Installation CD enclosed with this scanner.
For how to use the VRS, refer to the User's
Guide attached to the VRS Installation CD.
■ Preparation
HINT
Confirm the following items before installing the appli-
cation.
• Take out the Setup CD-ROM from its pack-
age, but do not insert the Setup CD-ROM
into the CD driver yet.
• Connect the scanner correctly to your PC.
For details on how to connect the scanner,
HINT
refer to "2.2 Connecting the Scanner to Your
2.3 Installing the Scanner
Application
For scanning documents with this scanner, both scanner
driver and image capturing application software (called
"application" hereafter) must be installed on your PC.
The following scanner drivers and applications are pro-
vided:
• Uninstall any older versions of the FUJITSU
TWAIN32 driver if it has already been
installed.
Uninstall [Scanner Utility for Microsoft Win-
dows] from [Add/Remove Programs] on
the control panel.
• Scanner Driver:
ATTENTION
FUJITSU TWAIN 32 Scanner Driver
FUJITSU ISIS Scanner Driver
• Scanning application:
ScandAll 21 (for FUJITSU TWAIN 32)
• There are two types of FUJITSU TWAIN32:
QuickScan Pro™ (for FUJITSU ISIS)
One of the following driver software will be
automatically installed according to your Oper-
ating System (OS).
Install the appropriate scanner driver for the application
you will use.
For Windows 98, Windows Me, Windows
2000, and Windows XP:
When using VRS, please be sure to install
ATTENTION
FUJITSU TWAIN32 V9
For Windows 95, Windows NT 4.0:
FUJITSU TWAIN32 V8
either the FUJITSU TWAIN 32 or the
FUJITSU ISIS scanner driver. The Soft-
ware Operation Panel will automatically be
installed together with the driver (TWAIN
or ISIS).
• When using Windows 95 or Windows NT
The Software Operation Panel is neces-
sary for changing the scanner settings.
4.0:
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ASPI Manager V4.01 or later is required (the
generally comes with SCSI board products).
■ Installing the FUJITSU TWAIN32
Scanner Driver
Windows XP screenshots are used in this
HINT
section. The windows and operations may
vary slightly depending on your OS.
1. Open the hopper.
5. Insert the Setup CD-ROM into the CD drive.
⇒ <SETUP DISK START UP SCREEN>
appears.
H
op
per
H
eigh
t
This screen may not appear when the
ATTENTION
"Autoplay" setting of your CD drive is off.
In this case, run "Install.exe" in this CD-
ROM directly from "Explorer" or "My Com-
puter".
Power button
6. Click [INSTALL PRODUCTS] J [TWAIN
Hopper
driver].
Be sure to open the hopper before turning
on the power with the Power button.
ATTENTION
2. Press the power button to turn the scanner ON.
3. Turn on your PC and log on to Windows.
When using Windows NT 4.0, Windows
ATTENTION
2000 or Windows XP, log on as a user with
"Administrator" privileges.
7. The Error Recovery Guide Installation window
appears.
⇒ The scanner is automatically detected and a
"Welcome to the Found New Wizard" (or
"Welcone to Add Hardware Wizard") screen
appears.
The Error Recovery Guide is a software that dis-
plays troubleshooting information on screen when
any scanner error occurs. Although this soft-
ware’s installation is highly recommended, it can
be installed later if you do not install it now.
4. Click the [Cancel] button and close the wizard
screen at the moment.
When you select [Yes] for installing the
ATTENTION
Error Recovery Guide, [Choose Setup Lan-
guage] window appears. Select a language
and follow the instructions in the window.
Error Recovery Guide will automatically
continue finishing its installation.
fi-5900C Image Scanner Getting Started
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Image Processing Software Option installation
windows appears.
Installation of the scanner driver is completed.
The Image Processing software is an optional
software that provides advanced binarization
image processing to the scanner dirver.
To confirm whether the installation was
ATTENTION
successful, perform a scanning operation
with an application that complies with the
TWAIN standards such as ScandAll 21.
Selecting [Yes] in the Image Processing
ATTENTION
Software Option installation window will
automatically execute the installation. Clic
the [OK] button on the confirmation mes-
sage that appears when the installation is
complete. After that the TWAIN driver
installation is started.
■ Installing ScandAll 21
"Scandall 21" is an image capturing software that com-
plies with the TWAIN standard.
When using Windows NT 4.0, Windows
2000 or Windows XP, log on as a user with
"Administrator" privileges
ATTENTION
9. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
1. Insert the Setup CD-ROM into a CD drive.
⇒ <SETUP DISK START UP SCREEN>
appears.
2. Click [INSTALL PRODUCTS] J [ScandAll 21].
10. Install the TWAIN driver following the instruc-
tions in the window.
11. When the [InstallShield Wizard Complete] win-
dow appears, click [Finish].
3. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
Your computer will be restarted and the scanner will be
detected. Do not remove the Setup CD-ROM from the
CD drive until your PC has completely restarted.
4. Continue to install the application following the
instructions in the window.
Depending on the OS, the following oper-
ations may be necessary.
ATTENTION
For Windows 98:
5. When the [InstallShield Wizard Complete] win-
dow appears, click [Finish]
When a request for inserting the CD-ROM
of Windows 98 appears, insert it into the
CD drive and click [OK].
For Windows 2000:
When [Digital Signature not Found]
appears, click [Yes].
8
Download from Www.Somanuals.com. All Manuals Search And Download.
For Windows 98, Windows Me, Windows
HINT
2000, Windows XP:
[FUJITSU Fi-5900Cd]
For Windows 95, Windows NT 4.0:
[FUJITSU TWAIN 32]
5. Select [To View...] from the [Scan] menu.
6. Select scanning resolution, document size, etc.
on the [TWAIN driver] window and click the
[Scan] button.
For finishing the installation, it may be nec-
essary to restart your computer. Follow the
instructions in the Window.
ATTENTION
■ Confirming Installation
1. Load documents on the scanner.
For details on how to set documents, refer to the
"2.6 Loading Documents on the Hopper" in the fi-
5900C Operator’s Guide provided in the CD-
ROM.
2. Start ScandAll21.
Select [Start] - [Programs] - [Scanner Utility for
Microsoft Windows] - [ScandAll 21].
For details on [TWAIN driver], refer to the
"FUJITSU TWAIN32 Scanner Driver Help"
HINT
provided in the Setup CD-ROM
3. Specify the scanner to use.
Select [Select Source...]from the [Scan] menu of
ScandAll 21.
7. Documents are scanned, and the generated
images are displayed in the [ScandAll 21] win-
dow.
4. Select "FUJITSU Fi-5900Cd" or "FUJITSU
TWAIN32" on the dialog box appeared.
If scanning is completed without trouble, the installation
was performed successfully.
For details on various types of scanning, refer to the
"fi-5900C Operator’s Guide" on the Setup CD-ROM.
fi-5900C Image Scanner Getting Started
9
Download from Www.Somanuals.com. All Manuals Search And Download.
For FUJITSU ISIS Scanner Driver
When using Windows NT 4.0, Windows
2000 or Windows XP, log on as a user with
"Administrator" privileges.
ATTENTION
■ Preparation
Confirm the following items before installing the appli-
cation.
⇒ If the scanner is automatically detected,
[Found New Hardware Wizard] or [Add/
Remove Hardware Wizard] dialog box will
appear.
• Take out the Setup CD-ROM from its pack-
age, but do not insert the Setup CD-ROM
into the CD driver yet.
4. Click [Cancel] to close the Wizard window.
• Connect the scanner correctly to your PC.
For details on how to connect the scanner,
HINT
■ Installing the FUJITSU ISIS
Scanner Driver
Windows XP screenshots are used in this
HINT
section as examples. The windows and
operations may vary slightly depending on
your OS.
5. Insert the "Setup CD-ROM" into the CD drive.
⇒ <SETUP DISK START UP SCREEN>
appears.
1. Open the hopper.
This screen may not appear when the
ATTENTION
"Autoplay" setting of your CD drive is off.
In this case, run "Install.exe" in this CD-
ROM directly from "Explorer" or "My Com-
puter".
H
op
per
H
eigh
t
6. Click [INSTALL PRODUCTS] and then click
[ISIS Driver].
Power button
Hopper
Be sure to open the hopper before turning
on the power with the Power button.
ATTENTION
2. Press the power button to turn the scanner ON.
3. Turn on your PC and log on to Windows.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
7. The Error Recovery Guide Installation window
appears.
Depending on the OS, the following oper-
ations may be necessary.
ATTENTION
The Error Recovery Guide is a software that dis-
plays troubleshooting information on screen if
any scanner error occurs. Although this soft-
ware’s installation is highly recommended, it can
be installed later if you do not install it in this
step.
For Windows 98:
When a request for inserting the CD-ROM
of Windows 98 appears, insert it into the
CD drive and click [OK].
For Windows 2000:
When [Digital Signature not Found]
appears, click [Yes].
When you select [Yes] for installing Error
ATTENTION
Recovery Guide, the [Choose Setup Lan-
guage] window appears. Select a lan-
guage and follow the instructions in the
Window. The Error Recovery Guide will
automatically continue finishing its installa-
tion.
The installation of the scanner driver is completed.
■ Installing QuickScan ProTM
"QuickScan ProTM" is an image capturing software that
complies with the ISIS standard.
8. Image Processing Software Option installation
windows appears.
When using Windows NT 4.0, Windows
ATTENTION
The Image Processing software is an optional
software that provides advanced binarization
image processing to the scanner dirver.
2000 or Windows XP, log on as a user with
"Administrator" privileges.
1. Insert the Setup CD-ROM into a CD drive.
Selecting [Yes] in the Image Processing
ATTENTION
⇒ <SETUP DISK STARTUP SCREEN>
Software Option installation window will
automatically execute the installation. Clic
the [OK] button on the confirmation mes-
sage that appears when the installation is
complete. After that the TWAIN driver
installation is started.
appears.
2. Click [INSTALL PRODUCTS] J [QuickScan
PRO (Trial)].
9. Select a language used for installation on
[Choose Setup Language] window and click
[OK].
.
3. Continue to install the application following the
instructions in the window.
10. Install the application following the instructions
in the window.
11. When the [InstallShield Wizard Complete] win-
dow appears, click [Finish].
Your computer will be restarted and the scanner will be
detected. Do not remove the Setup CD-ROM from the
CD drive until your PC has completely restarted.
fi-5900C Image Scanner Getting Started
11
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Enter required information, then click [Next >].
TM
"QuickScan Pro " included in the Setup
ATTENTION
6. Select [Preview Scan] from the [Scan] menu.
And then the document is scanned.
CD-ROM is an trial version. For further use
after expiration of the trial period (up to 30
launches), it is necessary to purchase a
TM
fully functional version of QuickScan
Pro. (When you install the trial version, do
not change the Serial Number already dis-
played.)
5. Install the application following the instructions
in the window.
■ Confirming Installation
1. Load documents on the scanner.
For details on loading documents, refer to "2.6
Loading Documents on the Hopper" in the fi-
5900C Operator's Guide on the Setup CD-ROM.
If the scanning completes without any trouble, the
installation was performed successfully.
2. Start QuickScan ProTM.
From [Start] menu select [Programs]-[Quick-
Scan]-[QuickScan].
Refer to "QuickScan Overview" or "Quick-
HINT
Scan Help" for information about Quick-
3. Select [Select Scanner...] from [Scan] menu in
QuickScan ProTM.
Scan functions and operations. On the
[Start] menu, point to [Programs]-[Quick-
Scan] and click the file.
4. And select fi-5900C from the list of [Scanner:],
and then click [OK] button.
Error Recovery Guide
The Error Recovery Guide is a software that displays
troubleshooting information on screen if any scanner
error occurs.
If you did not install the Error Recovery Guide when
installing the scanner driver, install it following the pro-
cedure below.
5. Select [Preview Settings...] from the [Scan]
menu. Set the scan resolution, paper size and
other scanning parameter, and then click [OK].
1. Insert the Setup CD-ROM into the CD drive.
⇒ <SETUP DISK STARTUP SCREEN>
appears.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Click [INSTALL PRODUCTS] and then click
[Error Recovery Guide].
Adobe Acrobat is required for displaying the
manuals stored in the CD-ROM.
* Installation of Adobe Acrobat is not neces-
sary if it has already been installed in your
PC.
HINT
1. Insert the Adobe Acrobat CD-ROM into the
CD-ROM drive.
⇒ The CD-ROM is automatically detected and
the "Adobe Acrobat" window appears.
This screen may not appear when the
ATTENTION
"Autoplay" setting of your CD drive is off.
In this case, run "AutoPlay.exe" in this CD-
ROM directly from "Explorer" or "My Com-
puter".
3. Select a language used for the installation in
the "Choose Setup Language" window and
click [OK].
2. Select a language and Click [OK] button.
4. Install the application following the instructions
in the window.
5. When the [InstallShield Wizard Complete] win-
dow appears, click [Finish].
3. Select "Install Adobe Acrobat".
®
®
Adobe Acrobat
Install Adobe Acrobat from the "Adobe Acrobat
CD-ROM" provided with this scanner.
4. Click the [Next] button. The set up window
appears.
Adobe Acrobat bundled with this scanner
ATTENTION
is not supported by Windows 95, Win-
dows 98 /98 Second Edition, Windows
NT4.0, Microsoft Windows Me.
fi-5900C Image Scanner Getting Started
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Support and User registration for Adobe
products:
ATTENTION
Refer to the technical support information
stored in the [Customer Support] folder on
Adobe Acrobat CD-ROM. (Note that free
person-to-person support is not available
for this is bundled product.)
■
Uninstalling Supplied Programs
5. Follow the instructions to install the software.
Follow the procedure below to uninstall supplied pro-
grams.
Select "How to install" on the "Adobe
HINT
Acrobat" window to learn more about
Windows XP screenshots are used in this
section. The windows and operations may
slightly vary depending on your OS.
HINT
Adobe Acrobat installation. Refer to
"Adobe Acrobat Help" about how to use
Adobe Acrobat.
1. Start up your PC.
Notes for using Adobe Acrobat:
ATTENTION
When scanning a document and convert-
ing the image to PDF using Adobe Acro-
bat, unexpected images may be output
when:
1. Setting "Edge Shadow Removal" in Acro-
bat, and setting "Digital Endorser" or
"Black Background" options in the
TWAIN driver at the same time. Letter
strings embedded in the image or the
background may be missed.
When using Windows NT 4.0, Windows
ATTENTION
2000 or Windows XP, log on as a user with
"Administrator" privileges (privileges of the
administrator of your PC).
2. Exit all currently running programs.
3. Select [Control Panel] - [Add or remove Pro-
grams] from the [Start] menu.
Solution 1: Set "Edge shadow removal"
to "OFF" or set any option other than
"Adaptive" for "Color/Grayscale" and/or
"Monochrome" under "Compression" by
selecting [File]->[Create PDF]-> [From
Scanner...]-> [Image Settings...] in Acro-
bat.
⇒ This displays the "Add or remove Programs"
screen which displays a list of the currently
installed applications.
Solution 2: Adjust the scanning density
in the TWAIN driver.
2. Setting "Adaptive" for "Color/Grayscale"
and/or "Monochrome" under "Compres-
sion" in Acrobat and scanning in a reso-
lution lower than the resolution
4. Select the application to uninstall.
• When uninstalling FUJITSU TWAIN 32
scanner driver,
select "Scanner Utility for Microsoft Win-
dows".
recommended for Acrobat.
• When uninstalling Scandall 21,
select "ScandAll 21".
Solution: Set OPTION to something
other than "Adaptive" under "Compres-
sion."
• When uninstalling FUJITSU ISIS scanner
3. Scanning a document longer than the
double letter (11x17) or A3 size, when
setting "Overscan" in the TWAIN driver,
the scan may fail.
Solution: When scanning a double letter
(11x17) or A3 size of document, do not
set "Overscan" in TWAIN driver.
*As for detailed usage and information of
Acrobat, refer to "Create a PDF file from a
scanned document" in Acrobat Help.
driver,
select "Fujitsu ISIS Drivers".
• When uninstalling QuickScan ProTM,
select "QuickScan 3.0".
• When uninstalling Error Recovery Guide,
select "Error Recovery Guide".
• When uninstalling Image Processing Soft-
ware Option,
select "Image Processing Software Option"
14
Download from Www.Somanuals.com. All Manuals Search And Download.
• When uninstalling Software Operation
Panel,
select "Software Operation Panel".
When uninstalling Adobe Acrobat, refer to
ATTENTION
the installation procedure described in the
Adobe Acrobat CD-ROM.
5. Click the [Change/Remove] or [Remove] but-
ton.
6. When the confirmation dialogbox appears,
Click the [OK] or [Yes] button.
⇒ This executes the uninstallation.
Screen displays may vary slightly accord-
ATTENTION
ing to the operation system (OS) you are
using. Follow the on screen instructions of
the OS.
Example: When the OS Windows 2000
•
"Add or Remove Programs" - "Add/
Remove Applications"
•
[Changel/Remove] button - [Add/
Remove] button.
fi-5900C Image Scanner Getting Started
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 1 TROUBLESHOOTING
■ Troubleshooting checklist
Symptom
Check this item
Remedy
Push the power button.
Scanner does not turn on.
Have you pushed the power button on
the front of the scanner?
Have you pushed the main power switch Push the Main power switch of the scanner. Then
at the back of the scanner?
push the power button.
Is the AC power cable properly con-
nected to the scanner?
Correctly connect the AC power able to the scan-
ner adapter.
Disconnect the AC power cable, then connect it
again.
If this does not restore the power supply, contact
the store where you purchased the scanner or an
authorized FUJITSU scanner service provider.
Scanning does not start.
Are documents loaded correctly on the
hopper?
Load documents correctly on the hopper.
Is the ADF closed completely?
Close the ADF completely.
Is the USB cable or SCSI cable properly Correctly connect the cable. (When a USB hub is
connected? used, check the hub's power supply.)
(When using the SCSI interface) Is SCSI Set SCSI ID correctly by SCSI ID switch on rear
ID set correctly? of scanner.
Does the Function Number Display indi- When the Function Number Display indicates an
cate an alarm or an error?
alarm or an error, refer to the "Chapter 6. TROU-
BLESHOOTING" in the fi-5900C Operator’s
Guide for removing the alarm or the error.
Does the alarm state remain displayed
even after the scanner has been turned
off and back on again?
Turn off and on the power button.
If this does not eliminate the alarm state, contact
the store where you purchased the scanner or an
authorized FUJITSU scanner service provider.
Vertical lines appear in the
scanned image.
Is the glass dirty?
Clean the glass following the instructions in the
Operator's Guide "4. Daily Care".
The scanned image shifts or
is distorted.
Are the documents loaded correctly?
Load the documents correctly.
Quality of generated image
is unsatisfactory.
Are the glass or sheet guides (Black/
White reference area) clean?
Clean the dirty locations.
Multifeed* frequently
occurs.
Do the documents satisfy the "Docu-
ment Quality" and the "Multifeed Detec- Quality" and the "Multifeed Detection Condi-
tion Conditions" in the chapter 7 of the
Scan the documents that satisfy the "Document
tions" in the chapter 7 of the fi-5900C Operator’s
*"Multifeed" is a phenome-
non when two or more
sheets of paper are fed
simultaneously into the
scanner.
fi-5900C Operator’s Guide?
Guide.
Are the documents set properly in the
hopper?
Fan the documents before scanning. Correctly
align the document stack and load them on the
hopper. Refer to " 2.6 Loading Document on Hop-
per" in the Operator’s Guide for details.
Is the document stack loaded on the hop- Reduce the number of sheets in the document
per thicker than 50mm (2 inch)?
stack to 50 mm (2 inch) thick or less.
Are the Brake roller, the Separator
roller or the Pad dirty?
Clean the Brake roller, the Separator roller or the
Pad. Refer to the Operator's Guide "4. Daily
Care".
Are the Brake roller, the Separator roller Replace the Brake roller, Separator roller or the
or the Pad worn out?
Pad. Refer to the Operator's Guide "5. Replacing
the Pad".
Have you set the document thickness on Set the document thickness thicker.
the Operator panel?
AP-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Symptom
Check this item
Remedy
Paper is not fed (pick error
occurs frequently, or docu-
ment stops midway).
Do the documents satisfy the "Docu-
ment Quality" and the "Multifeed Detec- Quality" and the "Multifeed Detection Condi-
tion Conditions" in the chapter 5 of the
fi-5900C Operator’s Guide?
Use the documents that satisfy the "Document
tions" in chapter 5 of the fi-5900C Operator’s
Guide.
Are the Separator roller or the Pick roll- Clean the Separator roller or the Pick rollers.
ers dirty? Refer to the Operator's Guide "4. Daily Care".
Are the Separator roller or the Pick roll- Replace the Separator roller or the Pick rollers.
ers worn out?
Refer to the Operator's Guide "5. Replacing of
Consumables".
Is there any debris on the document feed Remove any debris from the document feed path.
path?
Have you set the document thickness on Set the document thickness thinner.
the Operator panel?
The generated images are
elongated.
Are the Feed rollers or the Pinch rollers
dirty?
Clean the Feed rollers or the Pinch rollers. Refer
to the Operator's Guide "4. The Daily Care".
Have you adjusted the Vertical Magnifi- For Windows 98, Windows Me, Windows 2000,
cation?
Windows XP, select "Scanners and Cameras" in
the control panel. Right-click on fi-5900C and
select Properties. Click on the [Device Set] tab
and then click on the [Offset] button. Adjust the
Vertical Magnifcation.
For Windows 95, Windows NT 4.0, right-click the
Scanner Control Center in the task tray, select
[Options] and adjust the Vertical Magnification.
There is a shadow on the
leading edge of the gener-
ated image.
Have you adjusted the offset (the scan-
ning starting position)?
For Windows 98, Windows Me, Windows 2000,
Windows XP, adjust the [Sub-scan Setting] on
[Scanners and Cameras] in the control panel.
For Windows 95, Windows NT 4.0, right-click the
Scanner Control Center, select [Options]-[Sub-
scan Setting] and adjust the offset.
fi-5900C Image Scanner Getting Started
AP-2
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Temporary error
■ Device alarm (Permanent error)
Indication
Meaning
Indication
E0
Meaning
U1
U2
U4
A paper feed error occurred.
A multi feed error occurred.
Hopper or Stacker error
E2
E3
E4
E5
E6
E7
Optical system error (front)
Optical system error (back)
The motor fuse has blown out.
The lamp fuse has blown out.
Operator panel error
The ADF cover or the pre-imprinter
cover is opened.
U6
U8
The print cartridge is not set.
One of the following error occurred:
1. The document sensors are dirty.
2. The stacker is full.
3. The Brake roller or Separator rollers
are not installed properly.
Trouble occurred in the internal memory
(EEPROM).
E8
E9
EA
Ec
Ed
SCSI fuse has blown out
Image memory error
The following shows the procedure for releasing of each
of the temporary errors.
Imprinter error
Image memory error
• "U1" error
SCSI interface or USB interface
controller error
1. Remove the jammed documents.
(Refer to the fi-5900C Operator’s Guide "6.1
Clearing Document Jams" on the Setup CD-
ROM.)
2. Confirm that the documents meet the paper
specifications for scanning.
EF
Background switching mechanism error
ROM error
E10
E11
E12
E15
E16
E17
E18
E19
E1A
Cooling fan error
Heater error
(Refer to fi-5900C Operator’s Guide "7.2 Doc-
ument Quality" on the Setup CD-ROM.)
Extended memory error
Option board error
The imprinter fuse has blown out.
Sensor error
• "U2" error
Press the [Send to] button on the Operator Panel.
The documents that were multi fed will be
ejected.
LSI error
Troubles occurred in the communication
inside of the scanner.
• "U4" error
Close the ADF cover or pre-imprinter cover.
When you encounter any alarm, turn off and on the
scanner. If the alarm is still displayed on the Function
Number Display, contact the store where you purchased
the scanner or an authorized FUJITSU scanner service
provider.
• "U6" error
This is a temporary error related to the Imprinter
option (sold separately). For details, refer to the
"fi-590PRF/ fi-590PRB Operator's Guide, "5
Error Message".
• "U8" error
1. Clean the document sensors
For details refer to fi-5900C Operator’s Guide
“4.5 Cleaning the Transport path and the sen-
sors”.
2. Verify that the number of sheets ejected to the
stacker is below stacker’s capacity, and that
the Pick roller is not set for manual feeding.
3. Verify that the both rollers are installed prop-
erly. For details, refer to fi-5900C Operator’s
Guide "5.5 Replacing the Separator Rollers"
and "5.6 Replacing the Brake roller".
AP-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 2 DAILY CARE
■ Locations and Cycle for Cleaning
During its operation, the inside
glass of the ADF becomes very hot.
Before you clean inside the scan-
ner, turn off its power and unplug
the AC adapter from the outlet. Wait
for at least 15 minutes.
Do not turn off the scanner when
you clean the Feed rollers or Eject
rollers.
Part to clean
Standard Cleaning Cycle
Pad
Clean these parts after every
10,000 scans.
Pick rollers
Brake roller
Separator rollers
Feed rollers
Pinch rollers
Transport path
Glass
■ Cleaning Materials
Cleaning
Materials
Skew-detection sensor
Document sensor
Parts No.
Remarks
20 sheets/pack
For the cleaning method,
refer to "4 Daily Care in
the fi-5900C Operator"s
Guide.
Cleaning sheet CA99501-
0016
The scanner must be cleaned more fre-
quently if you scan any of the following
type of sheets:
ATTENTION
Cleaner F1
(or isopropyl
alcohol)
CA99501-
0013
1 bottle
•
•
Documents of coated paper
Moisten a cloth with this
fluid and wipe the scan-
ner to clean.
Documents that are almost completely
covered with printed text or graphics
Chemically treated documents such
as carbonless paper
•
•
•
Cleaner F2
CA99501-
0014
1 bottle
Documents containing a large amount
of calcium carbonate
Moisten a cloth with this
fluid and clean metal
rollers only.(Do not use
for any other parts.)
Documents written with pencil
Cotton swab
Commercially available
For details on the cleaning the ADF, refer to "4.Daily
Care" in the fi-5900C Operator’s Guide on the Setup
CD-ROM".
Lint-free dry
cloth
For details about the cleaning materials, contact the
FUJITSU scanner dealer where you purchased the scan-
ner.
■ Cleaning Method
The ADF must be cleaned with a lint-free cloth moist-
ened with the Cleaner F1.
The Feed roller must be cleaned with a lint-free cloth
moistened with the Cleaner F2.
fi-5900C Image Scanner Getting Started
AP-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix 3 REPLACING CONSUMABLES
The following illustrations show the locations of the
During its operation, the inside
consumables. Refer to "Chapter 5 Replacing Consum-
ables" fi-5900C Operator’s Guide on the Setup
CD-ROM.
glass of the ADF becomes very
hot.
Before replacing the
consumables, turn its power off
and unplug the AC adapter from
the outlet. Wait at least
15 minutes.
Pick roller
Separator roller
■ Consumables and Replacement
Cycle
The followings are the specifications of consumables
and their recommended replacement cycles.
Pad
Brake roller
Standard
Replacement Cycle
Description
Pad
Parts No.
■ Pad
PA03450-
K014
After 600,000 scans or
one year
Pad
To remove
Pick rollers
Brake roller
PA03450-
K011
After 600,000 scans or
one year
To install
PA03450-
K013
After 600,000 scans or
one year
Separator
rollers
PA03450-
K012
After 600,000 scans or
one year
To purchase consumables, contact the store where you
purchased the scanner or an authorized FUJITSU scanner
service provider.
The replacement cycles above are rough guidelines
when scanning A4/Letter sized, 20lb paper. This clean-
ing cycle varies according to the type of papers scanned
and how frequently the scanner is used and cleaned.
Use only the specified consumables.
ATTENTION
AP-5
Download from Www.Somanuals.com. All Manuals Search And Download.
■ Pick roller
■ Separator roller
Pick roller
Separator
roller
■ Brake roller
Cover
Pad
Brake roller
Cover
fi-5900C Image Scanner Getting Started
AP-6
Download from Www.Somanuals.com. All Manuals Search And Download.
fi-5900C Image Scanner Getting Started
P3PC-1422-03EN
Date of issuance: June, 2006
Issuance responsibility: PFU LIMITED
z Copying of the contents of this manual in whole or in part and
copying of the scanner application is forbidden under the
copyright law.
z The contents of this manual are subject to change without notice.
z PFU LIMITED is not liable whatsoever for any damages resulting
from use of this scanner and procedures described in this manual,
profit loss due to defects, and any claims by a third party.
Download from Www.Somanuals.com. All Manuals Search And Download.
|