Fujitsu Scanner fi 5900C User Manual

P3PC-1422-03EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Thank you for purchasing the fi-5900C Duplex Color  
Scanner.  
This document describes how to use fi-5900C and basic  
operation methods. Before you start using fi-5900C be  
sure to thoroughly read this manual to ensure correct  
use.  
The use of a shielded interface cable  
is required to comply with the Class B  
limits of Part 15 of FCC rules. The  
length of the SCSI interface cable  
must be 1.5 meters (5 feet) or less..  
NOTICE  
The length of the AC cable must be 3  
meters (10 feet) or less.  
The "Operator’s Guide" stored on the Setup CD-ROM  
provides useful and detailed information on Operations  
when you would like to use advanced features, Daily  
Care for maintenance of the scanner, and Replacing  
Consumables to maintain conditions for smooth scan-  
ning. Please also read the Operator’s Guide for further  
information.  
Canadian DOC Regulations  
This digital apparatus does not exceed the Class B  
limit for radio noise emissions from digital  
apparatus set out in the Radio interference  
Regulations of the Canadian Department of  
Communications.  
Regulatory Information  
This Class B digital apparatus complies with  
Canadian ICES-003.  
FCC declaration  
Le présent appareil numérique n'émet pas de  
parasites radioélectriques dépassant les limites  
applicables aux appareils numériques de la classe  
B et prescrites dans le Règlement sur le brouillage  
radioélectrique dictées par le Ministère des  
Communications du Canada.  
This equipment has been tested and found to  
comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. However,  
there is no guarantee that interference will not  
occur in a particular installation. If this equipment  
does cause harmful interference to radio or  
television reception, which can be determined by  
turning the equipment off and on, the user is  
encouraged to try to correct the interference by  
one or more of the following measures:  
Cet appareil numérique de la classe B est  
conforme à la norme NMB-003 du Canada.  
Bescheimigung des Herstellers /  
Importeurs  
Für den fi-5900C wird folgendes bescheinigt:  
In Übereinsstimmung mit den Bestimmungen  
der EN45014(CE) funkentstört  
Maschinenlärminformationsverordnung  
3.GPSGV: Der höchste Schalldruckpegel beträgt  
70 dB (A) oder weniger, gemäß EN ISO 7779.  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
®
International ENERGY STAR Program  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
located.  
As an ENERGY STAR®  
Partner, PFU LIMITED  
has determined that this  
product meets the  
Consult your dealer or an experienced radio/TV  
technician.  
ENERGY STAR®  
guidelines for energy  
efficiency.  
The International  
ENERGY STAR® Office  
FCC warning: Changes or modifications not  
expressly approved by the party responsible for  
compliance could void the user’s authority to  
operate the equipment.  
Equipment Program is an international program  
that promotes energy saving through the  
penetration of energy efficient computers and  
other office equipment. The program backs the  
development and dissemination of products with  
functions that effectively reduce energy  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
consumption. It is an open system in which  
business proprietors can participate voluntarily.  
The targeted products are office equipment such  
as computers, monitors, printers, facsimiles,  
copiers, scanners, and multifunction devices.  
Their standards and logos are uniform among  
participating nations.  
About the use of mercury  
Lamp(s) inside this product contain  
mercury and must be recycled or  
disposed of according to local, state, or  
federal laws.  
g
H
To avoid unexpected injuries;  
Do not put the substance contained in the lamp  
Note, Liability  
in your mouth as it has mercury.  
Do not breathe the chemical liquid contained in  
READ ALL OF THIS MANUAL CAREFULLY  
BEFORE USING THIS PRODUCT. IF THIS  
PRODUCT IS NOT USED CORRECTLY,  
UNEXPECTED INJURY MAY BE CAUSED TO  
USERS OR BYSTANDERS.  
the scanner lamps.  
Do not incinerate, crush, or shred the lamps or  
scanner parts.  
Also, keep this manual in a safe place so that it  
can be easily referred to during use of this  
product.  
Trademarks  
Microsoft, Windows, and Windows NT are  
registered trademarks of Microsoft Corporation in  
the United States and/or other countries.  
ISIS and QuickScan are trademarks or  
registered trademarks of EMC Corporation  
in the United States.  
While all efforts have been made to ensure the  
accuracy of all information in this manual, PFU  
assumes no liability to any party for any damage  
caused by errors or omissions or by statements of  
any kind in this manual, its updates or  
Adobe, the Adobe logo, and Acrobat are either  
registered trademarks of Adobe Systems  
Incorporated in the United States and/or other  
countries.  
Other product names are the trademarks or  
registered trademarks of the respective companies.  
supplements, whether such errors are omissions or  
statements resulting from negligence, accidents,  
or any other cause. PFU further assumes no  
liability arising from the application or use of any  
product or system described herein; nor any  
liability for incidental or consequential damages  
arising from the use of this manual. PFU disclaims  
all warranties regarding the information contained  
herein, whether expressed, implied, or statutory.  
How Trademarks Are Indicated In  
This Manual  
Use in High-safety Applications  
References to operating systems (OS) are  
indicated as follows:  
This product has been designed and manufactured  
on the assumption that it will be used in office,  
personal, domestic, regular industrial, and  
general-purpose applications. It has not been  
designed and manufactured for use in applications  
(simply called "high-safety applications" from  
here on) that directly involve danger to life and  
health when a high degree of safety is required,  
for example, in the control of nuclear reactions at  
nuclear power facilities, automatic flight control  
of aircraft, air traffic control, operation control in  
mass-transport systems, medical equipment for  
sustaining life, and missile firing control in  
weapons systems, and when provisionally the  
safety in question is not ensured. The user should  
use this product with adopting measures for  
ensuring safety in such high-safety applications.  
PFU LIMITED assumes no liability whatsoever  
for damages arising from use of this product by  
the user in high-safety applications, and for any  
claims or compensation for damages by the user  
or a third party.  
®
®
Microsoft Windows 95  
operating system  
Windows 95  
®
®
Microsoft Windows 98 /98 Second  
Edition operating system.  
Windows  
98/98SE  
®
®
Windows  
Me  
Microsoft Windows  
Millennium Edition operating system.  
®
®
Microsoft Windows NT 4.0  
Server operating system,  
Windows  
NT 4.0  
®
®
Microsoft Windows NT 4.0  
Workstation operating system.  
®
®
Windows  
2000  
Microsoft Windows 2000  
Professional operating system.  
®
®
Microsoft Windows XP  
Windows XP  
Professional operating system,  
®
®
Microsoft Windows XP  
Home Edition operating system.  
fi-5900C Image Scanner Getting Started  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Where there is no distinction between the different  
versions of the above operating system, the  
general term "Windows " is used.  
Symbols Used In This Manual  
This symbol alerts operators to particularly  
important information. Be sure to read this  
information.  
ATTENTION  
®
®
Adobe Acrobat  
Adobe Acrobat  
All the descriptions in this manual assume the  
usage of Adobe Acrobat bundled with this  
product. However, Adobe Acrobat may be  
upgraded without notice. If the descriptions differ  
from the screens actually displayed, refer to the  
Acrobat’s “Help”.  
This symbol alerts operators to helpful  
advice regarding operation.  
HINT  
Manufacturer  
A TRIANGLE symbol indicates that special care  
and attention is required.  
PFU LIMITED  
The drawing inside the triangle shows the  
specific caution.  
International Sales Dept., Imaging Business  
Division, Products Group  
Solid Square East Tower, 580 Horikawa-cho,  
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,  
Japan  
A CIRCLE with a diagonal line inside shows  
action which users may not perform.  
The drawing inside or under the circle shows the  
specific action that is not allowed.  
Phone : (81-44) 540-4538  
Outline characters on a colored background  
show instructions users should follow.  
All Rights Reserved, Copyright© PFU LIMITED 2006  
It may also include the drawing that shows the  
specific instruction.  
R
About Maintenance  
The user must not perform repairs on this scanner.  
Contact the store where you purchased the scanner  
or an authorized FUJITSU Image Scanner service  
provider to make repairs to this product.  
Warning Label  
The glass surface inside the ADF becomes hot  
during the operation. Be careful not to touch the  
glass surface inside the ADF.  
Warning Indications Used In This  
Manual  
Do NOT remove, stain or scratch the  
ATTENTION  
warning labels from the scanner.  
This indication alerts operators to an  
operation that, if not strictly  
observed, may result in severe injury  
or death.  
Screen Examples In This Manual  
This indication alerts operators to an  
operation that, if not strictly  
observed, may result in safety  
hazards to personnel or damage to  
equipment.  
The screen examples in this manual are subject to  
change without notice in the interest of product  
improvement. If the actual displayed screen  
differs from the screen examples in this manual,  
operate by following the actual displayed screen  
while referring to the User's Manual of the scanner  
application you are using.  
The screenshots in this manual were captured  
from FUJITSU TWAIN32 scanner driver,  
ScandAll 21 Image Capturing Utility Software,  
FUJITSU ISIS scanner driver, QuickScan Pro™  
image capturing software and Adobe® Acrobat®.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Turn the scanner OFF if it is damaged.  
If the scanner is damaged for any reason, turn  
off the scanner and unplug the AD cable before  
contacting the store you purchased the  
scanner.  
Do not damage the AC cable.  
Do not put liquids inside the scanner.  
A damaged AC cable may cause fire or electric  
Do not insert or drop metal objects in to the  
scanner. Do not scan wet documents or  
documents with paper clips or staples. Do not  
splash or allow the scanner to get wet.  
shock. Do not place heavy objects on AC  
cables, or pull, bend, twist, heat, damage or  
modify AC cables.  
Do not use damaged AC cables or power  
plugs, or install any cables or power plugs to  
loose wall sockets.  
If foreign objects (water, small metal objects,  
liquids, etc.) get inside the scanner, immediately  
turn off the scanner and disconnect the power  
plug from the power outlet, then contact the store  
where you bought the scanner or the  
Maintenance Service Center. Pay particular  
attention to this warning in households where  
there are small children.  
Use only specified AC cables and  
connector cables  
Use only specified AC cables and connector  
cables. Failure to use the correct cables might  
cause electric shock and/or equipment failure.  
Please don’t use the AC cable provided with  
this scanner for other devices, since this might  
cause equipment failure and other troubles or  
an electric shock.  
Do not touch the inside of the scanner  
unless necessary.  
Do not take apart or modify the scanner. The  
inside of the scanner contains high-voltage  
components. Touching these components might  
cause fire or electric shock.  
Use this scanner only at the indicated  
power voltage. Do not connect to multiple-  
power strips.  
Do not use the scanner if there is a strange  
odor.  
Use this scanner only at the indicated power  
voltage and current. Improper power voltage  
and current might cause fire or electric shock.  
Do not connect to multiple-power strips.  
If you detect excessive heat coming from the  
device or detect other problems such as smoke,  
strange smells or noises, disconnect immediately  
the power plug in order to turn out the scanner.  
Make sure that any smoke coming from it has  
stopped, before contacting the store where you  
bought the scanner or an authorized FUJITSU  
scanner service provider.  
Do not touch the AC cable with wet hands.  
Do not touch the power plug with wet hands.  
Doing so might cause electric shock.  
Wipe any dust from the power plug.  
Wipe off any dust from metal parts on the  
power plug or metal fittings with a soft, dry  
cloth. Accumulated dust might cause fire or  
electric shock.  
Do not install the device in locations that  
has oil smoke, steam, humidity, and dust.  
Do not install the scanner in locations subject  
to oil smoke, steam, humidity, and dust. Doing  
so might cause a fire or electric shock.  
fi-5900C Image Scanner Getting Started  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Before moving the scanner, disconnect the  
power plug from the power outlet.  
Do not move the scanner with the power and  
interface cables connected as this might  
damage the cables, causing fire, electric shock  
or injuries. Before moving the scanner, be sure  
to disconnect the power plug from the power  
outlet, and all other data cables. Make sure that  
the floor is free of any obstruction.  
Do not install the scanner on unstable  
surfaces.  
Make sure that the scanner is installed on a  
flat, level surface and that none of its parts  
extend beyond the surface top, such as a desk  
or table. Do not install the scanner on  
unstable surfaces. Install the scanner on a level  
surface that is free of vibration to prevent it  
from falling.  
Protect the scanner from static electricity.  
Install the scanner on a strong surface that will  
support the weight of the scanner and other  
devices.  
Install the scanner away from strong magnetic  
fields and other sources of electronic noise.  
Also, protect the scanner from any static  
electricity as this might cause the scanner to  
malfunction.  
Do not block the ventilation ports.  
Do not block the ventilation ports. Blocking the  
ventilation ports generates heat inside of  
scanner, which may results in fire or scanner  
failure.  
Do not use aerosol sprays near the  
scanner.  
Do not use aerosol sprays to clean the  
scanner. Aerosol sprays cause dirt and dust to  
enter the scanner, resulting scanner failure and  
malfunction.  
Do not place heavy objects or stand on top  
of the scanner.  
Do not place heavy objects on the scanner or  
use the scanner's surface top to perform other  
work. Improper installation might cause injuries  
and equipment failure.  
Disconnect the power plug from the power  
outlet when the scanner is not used for a  
long period of time.  
When the scanner is not going to be used for a  
long period of time, be sure to disconnect the  
power plug from the power outlet for safety.  
Firmly insert the power plug.  
Firmly insert the power plug as far it can go into  
the power outlet.  
Do not install the scanner in the direct  
sunlight.  
Avoid any contact when scanner is in use.  
Do not install the scanner under direct sunlight  
or near heating apparatus. Doing so might  
cause excessive heat to build up inside the  
scanner, which can cause scanner trouble or  
even fire. Install the scanner in a well-ventilated  
location.  
Avoid touching any scanner mechanism during  
scanning since this may cause injuries.  
Do not use the scanner immediately after  
moving it from a cold place into a warm  
room.  
Do not carry the scanner alone.  
When transporting the scanner, never carry it  
alone. The scanner is heavy.  
Do not use the device immediately after  
moving it from a cold place into a warm room.  
This may cause condensation, which might  
lead to scanning errors. Let the device dry  
about one or two hours before you use it.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter1 PREPARING THE SCANNER  
1.1 Checking the Contents of  
No.  
Name  
Function  
the Scanner Package  
9
ADF cover  
open button  
Button used to open the ADF  
When you unpack the scanner package, make sure that  
the package contains all the parts on the list included in  
the package.  
If any parts are missing or defective, contact your scan-  
ner dealer or an authorized FUJITSU scanner service  
provider. Handle the scanner and accessories with care.  
10  
11  
Pre-imprinter  
cover  
For the Pre-Imprinter option  
ADF  
The documents loaded onto the  
Hopper will be fed sheet by sheet  
for scanning.  
(Automatic  
document  
feeder)  
12  
13  
14  
Hopper  
extension  
Pulls the Hopper extension out for  
loading long documents.  
1.2 Names of Parts  
Hopper  
Documents to be scanned are  
loaded onto the Hopper.  
This section describes the names of parts.  
Hopper side  
guides  
Sheet Guides used to make sure  
that the paper to be scanned is fed  
into the scanner straight, avoiding  
skew.  
Front side  
15  
Power button  
Switches the scanner ON&OFF.  
2
3
4
5
6
1
Rear side  
7
8
1
2
9
10  
15  
3
5
4
7
8
6
11  
12  
No.  
Name  
Function  
14  
13  
1
Main power  
switch  
For switching the power support  
ON/OFF.  
No.  
Name  
Function  
2
3
Power inlet  
For connecting the AC cable.  
1
Stopper  
Prevents ejected documents from  
dropping off the scanner.  
SCSI ID Switch  
Sets the scanner’s SCSI ID with  
this switch.  
2
3
Stacker side  
guide  
4
5
6
SCSI connector  
USB connector  
For aligning ejected documents to  
a certain width.  
For connecting the SCSI cable.  
For connecting the USB cable.  
Top cover  
Cover to access the consumables  
storage box and Post Imprinter  
option (sold separately).  
Extended mem-  
ory slot  
For connecting an extension  
memory (sold separately).  
7
8
VRS slot  
The VRS board has been  
installed  
4
5
Stacker  
Ejector  
Area where ejected paper collects  
after scanning.  
Extended slot  
A spare slot for an option board  
For ejecting the documents after  
scanning.  
6
7
Operator  
panel  
For operating the scanner.  
Stacker  
extension  
For scanning long documents. Pull  
the extension out according to the  
document’s length.  
8
ADF cover  
Opens the cover for cleaning the  
inner parts of the ADF or for  
replacing consumables.  
fi-5900C Image Scanner Getting Started  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Removable Parts  
1.3 Operator panel  
The operator panel is located on the right side of the  
scanner. The panel consists of a Function Number Dis-  
play, buttons and a LED.  
Function number display  
1
Function  
Hopper Height  
Ho  
pp  
er  
He  
ihgt  
T
h
i
n
T
h
ic  
k
Paper Thickness  
Thin  
Thick  
Sendto  
Scan  
No.  
Name  
Description  
1
Document  
smoother  
Attached when the stacker posi-  
tion is set to align the ejected doc-  
ument by the leading edge, or  
when scanning documents with  
different widths.  
Name  
Function  
Shows the status of the scanner.  
Function  
For details, refer to "Indications on  
Hopper Height  
Use these buttons to adjust the height  
of the Hopper to the Upper/Middle/  
Lower Positions.  
2
3
The hopper moves automatically to  
the right position after giving a scan-  
ning command. However, this may  
cause a delay before the actual scan-  
ning starts. To avoid unnecessary  
waiting time, it is recommended to set  
the hopper height prior to scanning.  
The approximate loading capacities  
are as follows (* these numbers differ  
depending on the document thickness)  
Upper: 100 sheets  
4
5
Middle: 300 sheets  
Lower: 500 sheets  
No.  
Name  
Description  
Paper Thickness  
Use these buttons to adjust the paper  
thickness for the papers to be scanned.  
When picking errors or paper jams  
occur:  
Thin  
Thick  
2
Pick rollers  
Rollers that pick the paper from  
the hopper into the ADF. This is a  
consumable item.  
Press the  
When multifeed occurs:  
(Thin) button.  
3
4
5
Separator  
rollers  
Rollers used to help separate the  
paper as the feeding begins. This  
is a consumable item.  
Press the  
(Thick) button.  
Brake roller  
Pad  
Roller used to help separate the  
paper as the feeding begins. This  
is a consumable item.  
(Normally no need to change from the  
default setting)  
Use this button to start linked applica-  
tions (*About the settings, refer to the  
"fi-5900C Operator’s Guide" on the  
Setup CD-ROM).  
Send to  
Scan  
Separation Pad used to help sepa-  
rate the paper as the feeding  
begins. This is a consumable  
item.  
Use this button to turn the power ON/  
OFF.  
When the power is turned on, the but-  
ton is illuminated in blue.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Indications on the Function  
Operator Panel Overlays are available in  
French, German, Italian, Spanish, Chinese,  
Russian and Korean. To change the over-  
lay, open the plastic cover.  
Number Display  
HINT  
The following shows the indications on the Function  
Number Display.  
No.  
Descriptions  
Lights only one time upon turning on the scanner.  
Indicates that the scanner has been turned ON  
and is being initialized.  
Thin  
S
end  
to  
S
can  
Indicates that initialization has been completed  
successfully.  
This status is called "Ready Status".  
Indicates that a temporary error (that users can  
solve) has occurred during the initialization or  
scanning of documents.  
"U" and an error number (1, 2, 4, 6, 8) are dis-  
played alternately.  
To return the scanner to the ready status ("1"),  
press the "Scan" or "Send to" button while the  
error is indicated.  
Indicates that a device alarm (that users can not  
solve) has occurred during the initialization or  
scanning of documents.  
"E" and an alarm number (0, 2 to 9, and A, c, d,  
F, 10 to 12, 15 to 19, 1A) are indicated alter-  
nately.  
To return the scanner to the ready status ("1"),  
press "Scan" or "Send to" button.  
If this alarm occurs, turn the power off and then  
on again. If the alarm is indicated after turning on  
the power again, contact your service engineer.  
fi-5900C Image Scanner Getting Started  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter2  
INSTALLATION OF THE SCANNER  
2.1 Installing the Scanner  
2.2 Connecting the Scanner to  
Your PC  
1. Place the scanner at its installation site.  
When running Windows 95 or Windows NT 4.0, con-  
nect the scanner using the SCSI interface.  
When running Windows 98, Windows Me, Windows  
2000, or Windows XP, connect either using the USB or  
SCSI interface.  
For details on the scanner's dimensions and  
required installation space, refer to the fi-5900C  
Operator’s Guide, chapter "10. Scanner Specifi-  
cations".  
The scanner weight is 50 kg (110 lb).  
Make sure two persons are available  
when moving the scanner.  
ATTENTION  
This scanner is provided with two inter-  
ATTENTION  
faces: Ultra SCSI and USB 2.0 /1.1. Con-  
nect only one of the USB or SCSI cable.  
Windows 95 and Windows NT 4.0 do not  
support USB interface.  
When carrying the scanner, only grip the  
bottom side.  
2. Connect the AC cable to the Power inlet of the  
scanner and plug it into an outlet.  
Connecting the USB Interface  
1. Connect the USB cable to the USB connector.  
2. Connect the other end of the USB cable to  
your PC.  
Be sure to use the USB cable which  
comes with this scanner. Correct opera-  
tion with commercially available cables  
is not guaranteed.  
ATTENTION  
Use only the power cable provided by the  
manufacturer.  
ATTENTION  
When connecting to a USB hub, use the  
first stage USB hub that is closest to the  
computer. If you use the second or later  
hub stages, the scanner may not oper-  
ate correctly.  
If you connect the scanner with USB 2.0,  
it is required that the USB port and Hub  
are compliant with USB 2.0. The scan-  
ning speed may slow down if it is con-  
nected with USB1.1.  
The Function Number Display and the LED  
may flash for an instant when plugging the  
AC cable into the outlet. This is not a mal-  
function.  
HINT  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
3. Press the "I" side of the main power switch to  
turn on the scanner.  
3. Set the SCSI ID using the SCSI ID switch on  
the back of the scanner.  
OFF  
ON  
The SCSI ID is initially set to "5" at the factory.  
If the SCSI ID of another SCSI device is set to the  
same ID, either change the scanner's SCSI ID or  
SCSI ID of the other SCSI device.  
Connecting the SCSI interface  
When using the scanner with a SCSI interface, the fol-  
lowing SCSI cable and SCSI card must be purchased.  
ID No.  
0 to 7  
8, 9  
Description  
Can be set as the ID  
SCSI cable:  
Works with the factory default value  
(SCSI ID = 5).  
Use a SCSI cable whose connector on the scan-  
ner side is the 68-pin high-density shielded-type  
and whose connector on the PC side fits the con-  
nector of the SCSI card to use.  
When the scanner is turned on, the SCSI ID set is  
enabled.  
It is recommended to use a cable of length 1.5m  
or shorter.  
4. Press the "I" side of the main power switch to  
turn on the scanner.  
SCSI card  
Find the recommended SCSI card information  
on the Fujitsu web site (FAQ).  
computing/peripheral/scanners/scsi/  
OFF  
ON  
When connecting the SCSI cable, turn  
the scanner off. Be sure to connect the  
SCSI cable first, and then turn on the  
power of the scanner and PC.  
ATTENTION  
When using VRS  
In a SCSI daisy chain configuration,  
connect the scanner so that it is the ter-  
minated device.  
When using the Kofax® VRS, you need to connect it to  
the exclusive VRS board with either the USB cable or  
SCSI cable.  
1. Insert the SCSI cable into the interface connec-  
tor of the scanner until both sides click.  
1. If you use the USB cable, insert it into the inter-  
face connector (1) shown below.  
If you use the SCSI cable, insert it into the  
interface connector (2) shown below.  
SCSI ID Switch  
VRS board  
2. Connect the other end of the cable to your PC.  
2
1
Be careful not to bend the pins of the SCSI  
cable when connecting to the scanner.  
ATTENTION  
2. Connect the other end of the cable to your PC.  
fi-5900C Image Scanner Getting Started  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. When using the SCSI cable, set the SCSI ID  
using the SCSI ID switch on the back of the  
scanner.  
The following applications also come with fi-5900C.  
They will provide you more convenient and advanced  
usage.  
Error Recovery Guide  
The Error Recovery Guide is a software that dis-  
plays troubleshooting information on screen if  
any scanner error occurs.  
4. Press the "I" side of the main power switch to  
turn on the scanner.  
Adobe Acrobat  
De facto standard software for generating and  
manipulating PDF format electronic document.  
The following sections describe installation of each  
driver and application.  
OFF  
ON  
For FUJITSU TWAIN32 Scanner Driver  
VRS (VirtualReScan®) is the image process-  
ing software manufactured by Kofax Image  
Products, Inc.  
It enables to correct image defects, such as  
document skew when scanned by the scan-  
ner, or "jitter" generated by colors or half-tone  
dot meshing, and so on.  
You need to install the software in the VRS  
Installation CD enclosed with this scanner.  
For how to use the VRS, refer to the User's  
Guide attached to the VRS Installation CD.  
Preparation  
HINT  
Confirm the following items before installing the appli-  
cation.  
Take out the Setup CD-ROM from its pack-  
age, but do not insert the Setup CD-ROM  
into the CD driver yet.  
Connect the scanner correctly to your PC.  
For details on how to connect the scanner,  
HINT  
2.3 Installing the Scanner  
Application  
For scanning documents with this scanner, both scanner  
driver and image capturing application software (called  
"application" hereafter) must be installed on your PC.  
The following scanner drivers and applications are pro-  
vided:  
Uninstall any older versions of the FUJITSU  
TWAIN32 driver if it has already been  
installed.  
Uninstall [Scanner Utility for Microsoft Win-  
dows] from [Add/Remove Programs] on  
the control panel.  
Scanner Driver:  
ATTENTION  
FUJITSU TWAIN 32 Scanner Driver  
FUJITSU ISIS Scanner Driver  
Scanning application:  
ScandAll 21 (for FUJITSU TWAIN 32)  
There are two types of FUJITSU TWAIN32:  
QuickScan Pro(for FUJITSU ISIS)  
One of the following driver software will be  
automatically installed according to your Oper-  
ating System (OS).  
Install the appropriate scanner driver for the application  
you will use.  
For Windows 98, Windows Me, Windows  
2000, and Windows XP:  
When using VRS, please be sure to install  
ATTENTION  
FUJITSU TWAIN32 V9  
For Windows 95, Windows NT 4.0:  
FUJITSU TWAIN32 V8  
either the FUJITSU TWAIN 32 or the  
FUJITSU ISIS scanner driver. The Soft-  
ware Operation Panel will automatically be  
installed together with the driver (TWAIN  
or ISIS).  
When using Windows 95 or Windows NT  
The Software Operation Panel is neces-  
sary for changing the scanner settings.  
4.0:  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ASPI Manager V4.01 or later is required (the  
generally comes with SCSI board products).  
Installing the FUJITSU TWAIN32  
Scanner Driver  
Windows XP screenshots are used in this  
HINT  
section. The windows and operations may  
vary slightly depending on your OS.  
1. Open the hopper.  
5. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK START UP SCREEN>  
appears.  
H
op  
per  
H
eigh  
t
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your CD drive is off.  
In this case, run "Install.exe" in this CD-  
ROM directly from "Explorer" or "My Com-  
puter".  
Power button  
6. Click [INSTALL PRODUCTS] J [TWAIN  
Hopper  
driver].  
Be sure to open the hopper before turning  
on the power with the Power button.  
ATTENTION  
2. Press the power button to turn the scanner ON.  
3. Turn on your PC and log on to Windows.  
When using Windows NT 4.0, Windows  
ATTENTION  
2000 or Windows XP, log on as a user with  
"Administrator" privileges.  
7. The Error Recovery Guide Installation window  
appears.  
The scanner is automatically detected and a  
"Welcome to the Found New Wizard" (or  
"Welcone to Add Hardware Wizard") screen  
appears.  
The Error Recovery Guide is a software that dis-  
plays troubleshooting information on screen when  
any scanner error occurs. Although this soft-  
ware’s installation is highly recommended, it can  
be installed later if you do not install it now.  
4. Click the [Cancel] button and close the wizard  
screen at the moment.  
When you select [Yes] for installing the  
ATTENTION  
Error Recovery Guide, [Choose Setup Lan-  
guage] window appears. Select a language  
and follow the instructions in the window.  
Error Recovery Guide will automatically  
continue finishing its installation.  
fi-5900C Image Scanner Getting Started  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Image Processing Software Option installation  
windows appears.  
Installation of the scanner driver is completed.  
The Image Processing software is an optional  
software that provides advanced binarization  
image processing to the scanner dirver.  
To confirm whether the installation was  
ATTENTION  
successful, perform a scanning operation  
with an application that complies with the  
TWAIN standards such as ScandAll 21.  
Selecting [Yes] in the Image Processing  
ATTENTION  
Software Option installation window will  
automatically execute the installation. Clic  
the [OK] button on the confirmation mes-  
sage that appears when the installation is  
complete. After that the TWAIN driver  
installation is started.  
Installing ScandAll 21  
"Scandall 21" is an image capturing software that com-  
plies with the TWAIN standard.  
When using Windows NT 4.0, Windows  
2000 or Windows XP, log on as a user with  
"Administrator" privileges  
ATTENTION  
9. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
1. Insert the Setup CD-ROM into a CD drive.  
<SETUP DISK START UP SCREEN>  
appears.  
2. Click [INSTALL PRODUCTS] J [ScandAll 21].  
10. Install the TWAIN driver following the instruc-  
tions in the window.  
11. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish].  
3. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
Your computer will be restarted and the scanner will be  
detected. Do not remove the Setup CD-ROM from the  
CD drive until your PC has completely restarted.  
4. Continue to install the application following the  
instructions in the window.  
Depending on the OS, the following oper-  
ations may be necessary.  
ATTENTION  
For Windows 98:  
5. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish]  
When a request for inserting the CD-ROM  
of Windows 98 appears, insert it into the  
CD drive and click [OK].  
For Windows 2000:  
When [Digital Signature not Found]  
appears, click [Yes].  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
For Windows 98, Windows Me, Windows  
HINT  
2000, Windows XP:  
[FUJITSU Fi-5900Cd]  
For Windows 95, Windows NT 4.0:  
[FUJITSU TWAIN 32]  
5. Select [To View...] from the [Scan] menu.  
6. Select scanning resolution, document size, etc.  
on the [TWAIN driver] window and click the  
[Scan] button.  
For finishing the installation, it may be nec-  
essary to restart your computer. Follow the  
instructions in the Window.  
ATTENTION  
Confirming Installation  
1. Load documents on the scanner.  
For details on how to set documents, refer to the  
"2.6 Loading Documents on the Hopper" in the fi-  
5900C Operator’s Guide provided in the CD-  
ROM.  
2. Start ScandAll21.  
Select [Start] - [Programs] - [Scanner Utility for  
Microsoft Windows] - [ScandAll 21].  
For details on [TWAIN driver], refer to the  
"FUJITSU TWAIN32 Scanner Driver Help"  
HINT  
provided in the Setup CD-ROM  
3. Specify the scanner to use.  
Select [Select Source...]from the [Scan] menu of  
ScandAll 21.  
7. Documents are scanned, and the generated  
images are displayed in the [ScandAll 21] win-  
dow.  
4. Select "FUJITSU Fi-5900Cd" or "FUJITSU  
TWAIN32" on the dialog box appeared.  
If scanning is completed without trouble, the installation  
was performed successfully.  
For details on various types of scanning, refer to the  
"fi-5900C Operator’s Guide" on the Setup CD-ROM.  
fi-5900C Image Scanner Getting Started  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
For FUJITSU ISIS Scanner Driver  
When using Windows NT 4.0, Windows  
2000 or Windows XP, log on as a user with  
"Administrator" privileges.  
ATTENTION  
Preparation  
Confirm the following items before installing the appli-  
cation.  
If the scanner is automatically detected,  
[Found New Hardware Wizard] or [Add/  
Remove Hardware Wizard] dialog box will  
appear.  
Take out the Setup CD-ROM from its pack-  
age, but do not insert the Setup CD-ROM  
into the CD driver yet.  
4. Click [Cancel] to close the Wizard window.  
Connect the scanner correctly to your PC.  
For details on how to connect the scanner,  
HINT  
Installing the FUJITSU ISIS  
Scanner Driver  
Windows XP screenshots are used in this  
HINT  
section as examples. The windows and  
operations may vary slightly depending on  
your OS.  
5. Insert the "Setup CD-ROM" into the CD drive.  
<SETUP DISK START UP SCREEN>  
appears.  
1. Open the hopper.  
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your CD drive is off.  
In this case, run "Install.exe" in this CD-  
ROM directly from "Explorer" or "My Com-  
puter".  
H
op  
per  
H
eigh  
t
6. Click [INSTALL PRODUCTS] and then click  
[ISIS Driver].  
Power button  
Hopper  
Be sure to open the hopper before turning  
on the power with the Power button.  
ATTENTION  
2. Press the power button to turn the scanner ON.  
3. Turn on your PC and log on to Windows.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. The Error Recovery Guide Installation window  
appears.  
Depending on the OS, the following oper-  
ations may be necessary.  
ATTENTION  
The Error Recovery Guide is a software that dis-  
plays troubleshooting information on screen if  
any scanner error occurs. Although this soft-  
ware’s installation is highly recommended, it can  
be installed later if you do not install it in this  
step.  
For Windows 98:  
When a request for inserting the CD-ROM  
of Windows 98 appears, insert it into the  
CD drive and click [OK].  
For Windows 2000:  
When [Digital Signature not Found]  
appears, click [Yes].  
When you select [Yes] for installing Error  
ATTENTION  
Recovery Guide, the [Choose Setup Lan-  
guage] window appears. Select a lan-  
guage and follow the instructions in the  
Window. The Error Recovery Guide will  
automatically continue finishing its installa-  
tion.  
The installation of the scanner driver is completed.  
Installing QuickScan ProTM  
"QuickScan ProTM" is an image capturing software that  
complies with the ISIS standard.  
8. Image Processing Software Option installation  
windows appears.  
When using Windows NT 4.0, Windows  
ATTENTION  
The Image Processing software is an optional  
software that provides advanced binarization  
image processing to the scanner dirver.  
2000 or Windows XP, log on as a user with  
"Administrator" privileges.  
1. Insert the Setup CD-ROM into a CD drive.  
Selecting [Yes] in the Image Processing  
ATTENTION  
<SETUP DISK STARTUP SCREEN>  
Software Option installation window will  
automatically execute the installation. Clic  
the [OK] button on the confirmation mes-  
sage that appears when the installation is  
complete. After that the TWAIN driver  
installation is started.  
appears.  
2. Click [INSTALL PRODUCTS] J [QuickScan  
PRO (Trial)].  
9. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
.
3. Continue to install the application following the  
instructions in the window.  
10. Install the application following the instructions  
in the window.  
11. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish].  
Your computer will be restarted and the scanner will be  
detected. Do not remove the Setup CD-ROM from the  
CD drive until your PC has completely restarted.  
fi-5900C Image Scanner Getting Started  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Enter required information, then click [Next >].  
TM  
"QuickScan Pro " included in the Setup  
ATTENTION  
6. Select [Preview Scan] from the [Scan] menu.  
And then the document is scanned.  
CD-ROM is an trial version. For further use  
after expiration of the trial period (up to 30  
launches), it is necessary to purchase a  
TM  
fully functional version of QuickScan  
Pro. (When you install the trial version, do  
not change the Serial Number already dis-  
played.)  
5. Install the application following the instructions  
in the window.  
Confirming Installation  
1. Load documents on the scanner.  
For details on loading documents, refer to "2.6  
Loading Documents on the Hopper" in the fi-  
5900C Operator's Guide on the Setup CD-ROM.  
If the scanning completes without any trouble, the  
installation was performed successfully.  
2. Start QuickScan ProTM.  
From [Start] menu select [Programs]-[Quick-  
Scan]-[QuickScan].  
Refer to "QuickScan Overview" or "Quick-  
HINT  
Scan Help" for information about Quick-  
3. Select [Select Scanner...] from [Scan] menu in  
QuickScan ProTM.  
Scan functions and operations. On the  
[Start] menu, point to [Programs]-[Quick-  
Scan] and click the file.  
4. And select fi-5900C from the list of [Scanner:],  
and then click [OK] button.  
Error Recovery Guide  
The Error Recovery Guide is a software that displays  
troubleshooting information on screen if any scanner  
error occurs.  
If you did not install the Error Recovery Guide when  
installing the scanner driver, install it following the pro-  
cedure below.  
5. Select [Preview Settings...] from the [Scan]  
menu. Set the scan resolution, paper size and  
other scanning parameter, and then click [OK].  
1. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK STARTUP SCREEN>  
appears.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Click [INSTALL PRODUCTS] and then click  
[Error Recovery Guide].  
Adobe Acrobat is required for displaying the  
manuals stored in the CD-ROM.  
* Installation of Adobe Acrobat is not neces-  
sary if it has already been installed in your  
PC.  
HINT  
1. Insert the Adobe Acrobat CD-ROM into the  
CD-ROM drive.  
The CD-ROM is automatically detected and  
the "Adobe Acrobat" window appears.  
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your CD drive is off.  
In this case, run "AutoPlay.exe" in this CD-  
ROM directly from "Explorer" or "My Com-  
puter".  
3. Select a language used for the installation in  
the "Choose Setup Language" window and  
click [OK].  
2. Select a language and Click [OK] button.  
4. Install the application following the instructions  
in the window.  
5. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish].  
3. Select "Install Adobe Acrobat".  
®
®
Adobe Acrobat  
Install Adobe Acrobat from the "Adobe Acrobat  
CD-ROM" provided with this scanner.  
4. Click the [Next] button. The set up window  
appears.  
Adobe Acrobat bundled with this scanner  
ATTENTION  
is not supported by Windows 95, Win-  
dows 98 /98 Second Edition, Windows  
NT4.0, Microsoft Windows Me.  
fi-5900C Image Scanner Getting Started  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Support and User registration for Adobe  
products:  
ATTENTION  
Refer to the technical support information  
stored in the [Customer Support] folder on  
Adobe Acrobat CD-ROM. (Note that free  
person-to-person support is not available  
for this is bundled product.)  
Uninstalling Supplied Programs  
5. Follow the instructions to install the software.  
Follow the procedure below to uninstall supplied pro-  
grams.  
Select "How to install" on the "Adobe  
HINT  
Acrobat" window to learn more about  
Windows XP screenshots are used in this  
section. The windows and operations may  
slightly vary depending on your OS.  
HINT  
Adobe Acrobat installation. Refer to  
"Adobe Acrobat Help" about how to use  
Adobe Acrobat.  
1. Start up your PC.  
Notes for using Adobe Acrobat:  
ATTENTION  
When scanning a document and convert-  
ing the image to PDF using Adobe Acro-  
bat, unexpected images may be output  
when:  
1. Setting "Edge Shadow Removal" in Acro-  
bat, and setting "Digital Endorser" or  
"Black Background" options in the  
TWAIN driver at the same time. Letter  
strings embedded in the image or the  
background may be missed.  
When using Windows NT 4.0, Windows  
ATTENTION  
2000 or Windows XP, log on as a user with  
"Administrator" privileges (privileges of the  
administrator of your PC).  
2. Exit all currently running programs.  
3. Select [Control Panel] - [Add or remove Pro-  
grams] from the [Start] menu.  
Solution 1: Set "Edge shadow removal"  
to "OFF" or set any option other than  
"Adaptive" for "Color/Grayscale" and/or  
"Monochrome" under "Compression" by  
selecting [File]->[Create PDF]-> [From  
Scanner...]-> [Image Settings...] in Acro-  
bat.  
This displays the "Add or remove Programs"  
screen which displays a list of the currently  
installed applications.  
Solution 2: Adjust the scanning density  
in the TWAIN driver.  
2. Setting "Adaptive" for "Color/Grayscale"  
and/or "Monochrome" under "Compres-  
sion" in Acrobat and scanning in a reso-  
lution lower than the resolution  
4. Select the application to uninstall.  
When uninstalling FUJITSU TWAIN 32  
scanner driver,  
select "Scanner Utility for Microsoft Win-  
dows".  
recommended for Acrobat.  
When uninstalling Scandall 21,  
select "ScandAll 21".  
Solution: Set OPTION to something  
other than "Adaptive" under "Compres-  
sion."  
When uninstalling FUJITSU ISIS scanner  
3. Scanning a document longer than the  
double letter (11x17) or A3 size, when  
setting "Overscan" in the TWAIN driver,  
the scan may fail.  
Solution: When scanning a double letter  
(11x17) or A3 size of document, do not  
set "Overscan" in TWAIN driver.  
*As for detailed usage and information of  
Acrobat, refer to "Create a PDF file from a  
scanned document" in Acrobat Help.  
driver,  
select "Fujitsu ISIS Drivers".  
When uninstalling QuickScan ProTM,  
select "QuickScan 3.0".  
When uninstalling Error Recovery Guide,  
select "Error Recovery Guide".  
When uninstalling Image Processing Soft-  
ware Option,  
select "Image Processing Software Option"  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When uninstalling Software Operation  
Panel,  
select "Software Operation Panel".  
When uninstalling Adobe Acrobat, refer to  
ATTENTION  
the installation procedure described in the  
Adobe Acrobat CD-ROM.  
5. Click the [Change/Remove] or [Remove] but-  
ton.  
6. When the confirmation dialogbox appears,  
Click the [OK] or [Yes] button.  
This executes the uninstallation.  
Screen displays may vary slightly accord-  
ATTENTION  
ing to the operation system (OS) you are  
using. Follow the on screen instructions of  
the OS.  
Example: When the OS Windows 2000  
"Add or Remove Programs" - "Add/  
Remove Applications"  
[Changel/Remove] button - [Add/  
Remove] button.  
fi-5900C Image Scanner Getting Started  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix 1 TROUBLESHOOTING  
Troubleshooting checklist  
Symptom  
Check this item  
Remedy  
Push the power button.  
Scanner does not turn on.  
Have you pushed the power button on  
the front of the scanner?  
Have you pushed the main power switch Push the Main power switch of the scanner. Then  
at the back of the scanner?  
push the power button.  
Is the AC power cable properly con-  
nected to the scanner?  
Correctly connect the AC power able to the scan-  
ner adapter.  
Disconnect the AC power cable, then connect it  
again.  
If this does not restore the power supply, contact  
the store where you purchased the scanner or an  
authorized FUJITSU scanner service provider.  
Scanning does not start.  
Are documents loaded correctly on the  
hopper?  
Load documents correctly on the hopper.  
Is the ADF closed completely?  
Close the ADF completely.  
Is the USB cable or SCSI cable properly Correctly connect the cable. (When a USB hub is  
connected? used, check the hub's power supply.)  
(When using the SCSI interface) Is SCSI Set SCSI ID correctly by SCSI ID switch on rear  
ID set correctly? of scanner.  
Does the Function Number Display indi- When the Function Number Display indicates an  
cate an alarm or an error?  
alarm or an error, refer to the "Chapter 6. TROU-  
BLESHOOTING" in the fi-5900C Operator’s  
Guide for removing the alarm or the error.  
Does the alarm state remain displayed  
even after the scanner has been turned  
off and back on again?  
Turn off and on the power button.  
If this does not eliminate the alarm state, contact  
the store where you purchased the scanner or an  
authorized FUJITSU scanner service provider.  
Vertical lines appear in the  
scanned image.  
Is the glass dirty?  
Clean the glass following the instructions in the  
Operator's Guide "4. Daily Care".  
The scanned image shifts or  
is distorted.  
Are the documents loaded correctly?  
Load the documents correctly.  
Quality of generated image  
is unsatisfactory.  
Are the glass or sheet guides (Black/  
White reference area) clean?  
Clean the dirty locations.  
Multifeed* frequently  
occurs.  
Do the documents satisfy the "Docu-  
ment Quality" and the "Multifeed Detec- Quality" and the "Multifeed Detection Condi-  
tion Conditions" in the chapter 7 of the  
Scan the documents that satisfy the "Document  
tions" in the chapter 7 of the fi-5900C Operator’s  
*"Multifeed" is a phenome-  
non when two or more  
sheets of paper are fed  
simultaneously into the  
scanner.  
fi-5900C Operator’s Guide?  
Guide.  
Are the documents set properly in the  
hopper?  
Fan the documents before scanning. Correctly  
align the document stack and load them on the  
hopper. Refer to " 2.6 Loading Document on Hop-  
per" in the Operator’s Guide for details.  
Is the document stack loaded on the hop- Reduce the number of sheets in the document  
per thicker than 50mm (2 inch)?  
stack to 50 mm (2 inch) thick or less.  
Are the Brake roller, the Separator  
roller or the Pad dirty?  
Clean the Brake roller, the Separator roller or the  
Pad. Refer to the Operator's Guide "4. Daily  
Care".  
Are the Brake roller, the Separator roller Replace the Brake roller, Separator roller or the  
or the Pad worn out?  
Pad. Refer to the Operator's Guide "5. Replacing  
the Pad".  
Have you set the document thickness on Set the document thickness thicker.  
the Operator panel?  
AP-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Symptom  
Check this item  
Remedy  
Paper is not fed (pick error  
occurs frequently, or docu-  
ment stops midway).  
Do the documents satisfy the "Docu-  
ment Quality" and the "Multifeed Detec- Quality" and the "Multifeed Detection Condi-  
tion Conditions" in the chapter 5 of the  
fi-5900C Operator’s Guide?  
Use the documents that satisfy the "Document  
tions" in chapter 5 of the fi-5900C Operator’s  
Guide.  
Are the Separator roller or the Pick roll- Clean the Separator roller or the Pick rollers.  
ers dirty? Refer to the Operator's Guide "4. Daily Care".  
Are the Separator roller or the Pick roll- Replace the Separator roller or the Pick rollers.  
ers worn out?  
Refer to the Operator's Guide "5. Replacing of  
Consumables".  
Is there any debris on the document feed Remove any debris from the document feed path.  
path?  
Have you set the document thickness on Set the document thickness thinner.  
the Operator panel?  
The generated images are  
elongated.  
Are the Feed rollers or the Pinch rollers  
dirty?  
Clean the Feed rollers or the Pinch rollers. Refer  
to the Operator's Guide "4. The Daily Care".  
Have you adjusted the Vertical Magnifi- For Windows 98, Windows Me, Windows 2000,  
cation?  
Windows XP, select "Scanners and Cameras" in  
the control panel. Right-click on fi-5900C and  
select Properties. Click on the [Device Set] tab  
and then click on the [Offset] button. Adjust the  
Vertical Magnifcation.  
For Windows 95, Windows NT 4.0, right-click the  
Scanner Control Center in the task tray, select  
[Options] and adjust the Vertical Magnification.  
There is a shadow on the  
leading edge of the gener-  
ated image.  
Have you adjusted the offset (the scan-  
ning starting position)?  
For Windows 98, Windows Me, Windows 2000,  
Windows XP, adjust the [Sub-scan Setting] on  
[Scanners and Cameras] in the control panel.  
For Windows 95, Windows NT 4.0, right-click the  
Scanner Control Center, select [Options]-[Sub-  
scan Setting] and adjust the offset.  
fi-5900C Image Scanner Getting Started  
AP-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temporary error  
Device alarm (Permanent error)  
Indication  
Meaning  
Indication  
E0  
Meaning  
U1  
U2  
U4  
A paper feed error occurred.  
A multi feed error occurred.  
Hopper or Stacker error  
E2  
E3  
E4  
E5  
E6  
E7  
Optical system error (front)  
Optical system error (back)  
The motor fuse has blown out.  
The lamp fuse has blown out.  
Operator panel error  
The ADF cover or the pre-imprinter  
cover is opened.  
U6  
U8  
The print cartridge is not set.  
One of the following error occurred:  
1. The document sensors are dirty.  
2. The stacker is full.  
3. The Brake roller or Separator rollers  
are not installed properly.  
Trouble occurred in the internal memory  
(EEPROM).  
E8  
E9  
EA  
Ec  
Ed  
SCSI fuse has blown out  
Image memory error  
The following shows the procedure for releasing of each  
of the temporary errors.  
Imprinter error  
Image memory error  
"U1" error  
SCSI interface or USB interface  
controller error  
1. Remove the jammed documents.  
(Refer to the fi-5900C Operator’s Guide "6.1  
Clearing Document Jams" on the Setup CD-  
ROM.)  
2. Confirm that the documents meet the paper  
specifications for scanning.  
EF  
Background switching mechanism error  
ROM error  
E10  
E11  
E12  
E15  
E16  
E17  
E18  
E19  
E1A  
Cooling fan error  
Heater error  
(Refer to fi-5900C Operator’s Guide "7.2 Doc-  
ument Quality" on the Setup CD-ROM.)  
Extended memory error  
Option board error  
The imprinter fuse has blown out.  
Sensor error  
"U2" error  
Press the [Send to] button on the Operator Panel.  
The documents that were multi fed will be  
ejected.  
LSI error  
Troubles occurred in the communication  
inside of the scanner.  
"U4" error  
Close the ADF cover or pre-imprinter cover.  
When you encounter any alarm, turn off and on the  
scanner. If the alarm is still displayed on the Function  
Number Display, contact the store where you purchased  
the scanner or an authorized FUJITSU scanner service  
provider.  
"U6" error  
This is a temporary error related to the Imprinter  
option (sold separately). For details, refer to the  
"fi-590PRF/ fi-590PRB Operator's Guide, "5  
Error Message".  
"U8" error  
1. Clean the document sensors  
For details refer to fi-5900C Operator’s Guide  
“4.5 Cleaning the Transport path and the sen-  
sors”.  
2. Verify that the number of sheets ejected to the  
stacker is below stacker’s capacity, and that  
the Pick roller is not set for manual feeding.  
3. Verify that the both rollers are installed prop-  
erly. For details, refer to fi-5900C Operator’s  
Guide "5.5 Replacing the Separator Rollers"  
and "5.6 Replacing the Brake roller".  
AP-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix 2 DAILY CARE  
Locations and Cycle for Cleaning  
During its operation, the inside  
glass of the ADF becomes very hot.  
Before you clean inside the scan-  
ner, turn off its power and unplug  
the AC adapter from the outlet. Wait  
for at least 15 minutes.  
Do not turn off the scanner when  
you clean the Feed rollers or Eject  
rollers.  
Part to clean  
Standard Cleaning Cycle  
Pad  
Clean these parts after every  
10,000 scans.  
Pick rollers  
Brake roller  
Separator rollers  
Feed rollers  
Pinch rollers  
Transport path  
Glass  
Cleaning Materials  
Cleaning  
Materials  
Skew-detection sensor  
Document sensor  
Parts No.  
Remarks  
20 sheets/pack  
For the cleaning method,  
refer to "4 Daily Care in  
the fi-5900C Operator"s  
Guide.  
Cleaning sheet CA99501-  
0016  
The scanner must be cleaned more fre-  
quently if you scan any of the following  
type of sheets:  
ATTENTION  
Cleaner F1  
(or isopropyl  
alcohol)  
CA99501-  
0013  
1 bottle  
Documents of coated paper  
Moisten a cloth with this  
fluid and wipe the scan-  
ner to clean.  
Documents that are almost completely  
covered with printed text or graphics  
Chemically treated documents such  
as carbonless paper  
Cleaner F2  
CA99501-  
0014  
1 bottle  
Documents containing a large amount  
of calcium carbonate  
Moisten a cloth with this  
fluid and clean metal  
rollers only.(Do not use  
for any other parts.)  
Documents written with pencil  
Cotton swab  
Commercially available  
For details on the cleaning the ADF, refer to "4.Daily  
Care" in the fi-5900C Operator’s Guide on the Setup  
CD-ROM".  
Lint-free dry  
cloth  
For details about the cleaning materials, contact the  
FUJITSU scanner dealer where you purchased the scan-  
ner.  
Cleaning Method  
The ADF must be cleaned with a lint-free cloth moist-  
ened with the Cleaner F1.  
The Feed roller must be cleaned with a lint-free cloth  
moistened with the Cleaner F2.  
fi-5900C Image Scanner Getting Started  
AP-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix 3 REPLACING CONSUMABLES  
The following illustrations show the locations of the  
During its operation, the inside  
consumables. Refer to "Chapter 5 Replacing Consum-  
ables" fi-5900C Operator’s Guide on the Setup  
CD-ROM.  
glass of the ADF becomes very  
hot.  
Before replacing the  
consumables, turn its power off  
and unplug the AC adapter from  
the outlet. Wait at least  
15 minutes.  
Pick roller  
Separator roller  
Consumables and Replacement  
Cycle  
The followings are the specifications of consumables  
and their recommended replacement cycles.  
Pad  
Brake roller  
Standard  
Replacement Cycle  
Description  
Pad  
Parts No.  
Pad  
PA03450-  
K014  
After 600,000 scans or  
one year  
Pad  
To remove  
Pick rollers  
Brake roller  
PA03450-  
K011  
After 600,000 scans or  
one year  
To install  
PA03450-  
K013  
After 600,000 scans or  
one year  
Separator  
rollers  
PA03450-  
K012  
After 600,000 scans or  
one year  
To purchase consumables, contact the store where you  
purchased the scanner or an authorized FUJITSU scanner  
service provider.  
The replacement cycles above are rough guidelines  
when scanning A4/Letter sized, 20lb paper. This clean-  
ing cycle varies according to the type of papers scanned  
and how frequently the scanner is used and cleaned.  
Use only the specified consumables.  
ATTENTION  
AP-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Pick roller  
Separator roller  
Pick roller  
Separator  
roller  
Brake roller  
Cover  
Pad  
Brake roller  
Cover  
fi-5900C Image Scanner Getting Started  
AP-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fi-5900C Image Scanner Getting Started  
P3PC-1422-03EN  
Date of issuance: June, 2006  
Issuance responsibility: PFU LIMITED  
z Copying of the contents of this manual in whole or in part and  
copying of the scanner application is forbidden under the  
copyright law.  
z The contents of this manual are subject to change without notice.  
z PFU LIMITED is not liable whatsoever for any damages resulting  
from use of this scanner and procedures described in this manual,  
profit loss due to defects, and any claims by a third party.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eizo Computer Monitor CG303W User Manual
Excalibur electronic Board Games NF 07 User Manual
FujiFilm Digital Camera 106 8620 User Manual
Gardena Outdoor Timer T 14 e User Manual
GE Cooktop 164D2966P161 1 User Manual
Gefen Home Theater System EXT COMPAUD 44424 User Manual
GE Microwave Oven JE1468L User Manual
GE Telephone 29267 User Manual
GE Water System GXSF18G User Manual
Gianni Industries Door GL 1200F User Manual