Fujitsu Scanner fi 5120C User Manual

P3PC-1312-02EN  
fi-5120C/fi-5220C Image Scanner  
Getting Started  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Thank you for purchasing the fi-5120C/fi-5220C  
Duplex Color Scanner product.  
Canadian DOC Regulations  
This document describes how to handle fi-5120C/fi-  
5220C Duplex Color and basic operation methods.  
Before you start using fi-5120C/fi-5220C Duplex Color  
be sure to thoroughly read this manual to ensure correct  
use.  
This digital apparatus does not exceed the Class B  
limit for radio noise emissions from digital  
apparatus set out in the Radio interference  
Regulations of the Canadian Department of  
Communications.  
This Class B digital apparatus complies with  
Canadian ICES-003.  
The "Operator’s Guide" is stored on the Setup Disk.  
The guide provides useful and detailed information on  
Operations when you would like to using advanced fea-  
tures, daily maintenance of the scanner, replacement of  
consumables.Please also read the Operator’s Guide for  
your reference.  
Le présent appareil numérique n'émet pas de  
parasites radioélectriques dépassant les limites  
applicables aux appareils numériques de la classe  
B et prescrites dans le Règlement sur le brouillage  
radioélectrique dictées par le Ministère des  
Communications du Canada.  
Regulatory Information  
Cet appareil numérique de la classe B est  
conforme à la norme NMB-003 du Canada.  
FCC Declaration  
Bescheimigung des Herstellers /  
Importeurs  
This equipment has been tested and found to  
comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. However,  
there is no guarantee that interference will not  
occur in a particular installation. If this equipment  
does cause harmful interference to radio or  
television reception, which can be determined by  
turning the equipment off and on, the user is  
encouraged to try to correct the interference by  
one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
Für den fi-5120C/fi-5220C wird folgendes  
bescheinigt:  
In Übereinsstimmung mit den Bestimmungen  
der EN45014(CE) funkentstört  
Maschinenlärminformationsverordnung 3.  
GPSGV: Der höchste Schalldruckpegel beträgt  
70 dB (A) oder weniger, gemäß EN ISO 7779.  
®
International ENERGY STAR Program  
As an ENERGY  
STAR® Partner, PFU  
LIMITED has  
determined that this  
product meets the  
ENERGY STAR®  
guidelines for energy  
efficiency.  
The International  
ENERGY STAR®  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
located.  
Consult your dealer or an experienced radio/TV  
technician.  
Office Equipment Program is an international  
program that promotes energy saving through the  
penetration of energy efficient computers and  
other office equipment. The program backs the  
development and dissemination of products with  
functions that effectively reduce energy  
consumption. It is an open system in which  
business proprietors can participate voluntarily.  
The targeted products are office equipment such  
as computers, monitors, printers, facsimiles,  
copiers, scanners, and multifunction devices.  
Their standards and logos are uniform among  
participating nations.  
FCC warning: Changes or modifications not  
expressly approved by the party responsible for  
compliance could void the user’s authority to  
operate the equipment.  
The use of a shielded interface cable is  
ATTENTION  
required to comply with the Class B limits  
of Part 15 of FCC rules.  
The length of the AC cable must be 2  
meters (6.6 feet) or less.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Do not breathe the chemical liquid contained in  
the scanner lamps.  
Note, Liability  
Do not incinerate, crush, or shred the lamps or  
BEFORE USING THIS PRODUCT, PLEASE  
READ THIS MANUAL CAREFULLY. IF THIS  
PRODUCT IS NOT USED CORRECTLY,  
UNEXPECTED INJURY CAN OCCUR TO  
USERS OR BYSTANDERS.  
scanner parts.  
Trademarks  
Microsoft, Windows, and Windows NT are  
registered trademarks of Microsoft Corporation in  
the United States and/or other countries.  
ISIS and QuickScan are trademarks or registered  
trademarks of EMC Corporation in the United  
States.  
Adobe, the Adobe logo, and Acrobat are either  
registered trademarks of Adobe Systems  
Incorporated in the United States and/or other  
countries.  
Keep this manual in a safe place so that it can be  
easily referred to during use of this product.  
While all efforts have been made to ensure the  
accuracy of all information in this manual, PFU  
assumes no liability to any party for any damage  
caused by errors or omissions or by statements of  
any kind in this manual, its updates or  
supplements, whether such errors are omissions or  
statements resulting from negligence, accidents,  
or any other cause. PFU further assumes no  
liability arising from the application or use of any  
product or system described herein; nor any  
liability for incidental or consequential damages  
arising from the use of this manual. PFU disclaims  
all warranties regarding the information contained  
herein, whether expressed, implied, or statutory.  
Other product names are the trademarks or  
registered trademarks of the respective companies.  
How Trademarks Are Indicated In  
This Manual  
References to operating systems (OS) and  
applications are indicated as follows:  
Use in High-safety Applications  
®
®
Microsoft Windows 95  
operating system  
Windows 95  
Windows 98  
Windows Me  
This product has been designed and manufactured  
on the assumption that it will be used in office,  
personal, domestic, regular industrial, and  
general-purpose applications. It has not been  
designed and manufactured for use in applications  
(simply called "high-safety applications" from  
here on) that directly involve danger to life and  
health when a high degree of safety is required,  
for example, in the control of nuclear reactions at  
nuclear power facilities, automatic flight control  
of aircraft, air traffic control, operation control in  
mass-transport systems, medical equipment for  
sustaining life, and missile firing control in  
weapons systems, and when provisionally the  
safety in question is not ensured. The user should  
use this product with adopting measures for  
ensuring safety in such high-safety applications.  
PFU LIMITED assumes no liability whatsoever  
for damages arising from use of this product by  
the user in high-safety applications, and for any  
claims or compensation for damages by the user  
or a third party.  
®
®
Microsoft Windows 98  
operating system.  
®
®
Microsoft Windows Millen-  
nium Edition operating system.  
®
®
Windows NT  
4.0  
Microsoft Windows NT 4.0  
Server operating system,  
®
®
Microsoft Windows NT 4.0  
Workstation operating system.  
®
®
Microsoft Windows 2000 Pro-  
fessional operating system.  
Windows 2000  
Windows XP  
®
®
Microsoft Windows XP  
Professional operating system,  
®
®
Microsoft Windows XP Home  
Edition operating system.  
Where there is no distinction between the different  
versions of the above operating system, the  
general term "Windows " is used.  
About the Use of Mercury  
Ff  
®
®
Lamp(s) inside this product contain mer-  
cury and must be recycled or disposed of  
Adobe Acrobat  
Adobe Acrobat  
g
H
according to local, state, or federal laws.  
All the descriptions in this manual assume the  
usage of Adobe Acrobat bundled with this  
product. However, Adobe Acrobat may be  
upgraded without notice. If the descriptions differ  
from the screens actually displayed, refer to the  
Acrobat’s “Help”.  
To avoid unexpected injuries:  
Do not put the substance contained in the lamp  
in your mouth as it has mercury.  
fi-5120C/fi-5220C Image Scanner Getting Started  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Manufacturer  
Outline characters on a colored  
background show instructions users should  
follow.  
It may also include the drawing that shows  
the specific instruction.  
PFU LIMITED  
International Sales Dept., Imaging Business  
Division, Products Group  
R
Solid Square East Tower, 580 Horikawa-cho,  
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,  
Japan  
Warning Label  
Phone : (81-44) 540-4538  
The glass surface inside the ADF becomes  
hot during the operation. Be careful not to  
touch the glass surface inside the ADF.  
All Rights Reserved, Copyright© PFU LIMITED 2006.  
About Maintenance  
The user must not perform repairs on this scanner.  
Contact the store where you purchased the scanner  
or an authorized FUJITSU Image Scanner service  
provider to have repairs done on this product.  
Do NOT remove from the scanner, stain or  
scratch the warning labels.  
ATTENTION  
Warning Indications Used In This  
Manual  
Screen Examples In This Manual  
The screen examples in this manual are subject to  
change without notice in the interest of product  
improvement. If the actual displayed screen  
differs from the screen examples in this manual,  
operate by following the actual displayed screen  
while referring to the User's Manual of the scanner  
application you are using.  
This indication alerts operators  
to an operation that, if not strictly  
observed, may result in severe  
injury or death.  
This indication alerts operators to  
an operation that, if not strictly  
observed, may result in safety  
hazards to personnel or damage  
to equipment.  
The screenshots in this manual were captured  
from FUJITSU TWAIN32 scanner driver,  
ScandAll 21 Image Capturing Utility Software,  
FUJITSU ISIS scanner driver, QuickScan™  
image capturing software and Adobe® Acrobat®.  
Symbols Used In This Manual  
This symbol alerts operators to particularly  
ATTENTION  
important information. Be sure to read this  
information.  
This symbol alerts operators to helpful  
HINT  
advice regarding operation.  
A TRIANGLE symbol indicates that special  
care and attention is required.  
The drawing inside the triangle shows the  
specific caution.  
A CIRCLE with a diagonal line inside  
shows action which users may not perform.  
The drawing inside or under the circle  
shows the specific action that is not  
allowed.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Do not install the device in locations  
that has oil smoke, steam, humidity,  
and dust.  
Do not install the scanner in locations  
subject to oil smoke, steam, humidity, and  
dust. Doing so might cause a fire or electric  
shock.  
Do not damage the AC cable.  
A damaged AC cable may cause fire or  
electric shock. Do not place heavy objects  
on AC cables, or pull, bend, twist, heat,  
damage or modify AC cables.  
Do not use damaged AC cables or power  
plugs, or install any cables or power plugs  
to loose wall sockets.  
Turn the scanner OFF if it is  
damaged.  
If the scanner is damaged for any reason,  
turn the scanner off and unplug the power  
cable. Contact the store where you  
purchased the scanner.  
Use only specified AC cables and  
connector cables.  
Do not put liquids inside the scanner.  
Use only specified AC cables and connector  
cables. Failure to use the correct cables  
might cause electric shock and/or  
equipment failure.  
Please don’t use the AC cable provided with  
this scanner for other devices, since this  
might cause equipment failure and other  
troubles or an electric shock.  
Do not insert or drop metal objects in to the  
scanner. Do not scan wet documents or  
documents with paper clips or staples. Do  
not splash or allow the scanner to get wet.  
If foreign objects (water, small metal  
objects, liquids, etc.) get inside the scanner,  
immediately turn off the scanner and dis-  
connect the power plug from the power out-  
let. Then, contact the store where you  
bought the scanner or the Maintenance Ser-  
vice Center. Pay particular attention to this  
warning in households where there are  
small children.  
Use this scanner only at the  
indicated power voltage. Do not  
connect to multiple-power strips.  
Use this scanner only at the indicated  
power voltage and current. Improper power  
voltage and current might cause fire or  
electric shock. Do not connect to multiple-  
power strips.  
Do not touch the inside of the  
scanner unless necessary.  
Do not take apart or modify the scanner.  
The inside of the scanner contains high-  
voltage components. Touching these  
components might cause electric shock or  
fire.  
Do not touch the AC cable with wet  
hands.  
Do not touch the power plug with wet  
hands. Doing so might cause electric shock.  
Do not use the scanner if you smell a  
strange odor.  
Wipe any dust from the power plug.  
If you detect heat coming from the device or  
detect other problems such as smoke,  
strange smells or noises, immediately turn  
off the scanner and then disconnect its  
power plug. Make sure that any smoke  
coming from it has stopped, before  
contacting the store where you bought the  
scanner or an authorized FUJITSU scanner  
service provider.  
Wipe off any dust from metal parts on the  
power plug or metal fittings with a soft, dry  
cloth. Accumulated dust might cause fire or  
electric shock.  
fi-5120C/fi-5220C Image Scanner Getting Started  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Before moving the scanner,  
disconnect the power plug from the  
power outlet.  
Do not install the scanner on  
unstable surfaces.  
Do not move the scanner with the power  
and interface cables connected as this can  
damage the cables, which can later cause  
fire, electric shock as well as injury.  
Before moving the scanner, be sure to  
disconnect the power plug from the power  
outlet, and all other data cables.  
Make sure that the scanner is installed on a  
flat, level surface and that none of its parts  
extend beyond the surface top, such as a  
desk or table. Do not install the scanner on  
unstable surfaces. Install the scanner on a  
level surface that is free of vibration to  
prevent it from falling.  
Install the scanner on a strong surface that  
will support the weight of the scanner and  
other devices.  
Make sure that the floor is free of any  
obstructions.  
Protect the scanner from static  
electricity.  
Do not block the ventilation ports.  
Install the scanner away from strong  
magnetic fields and other sources of  
electronic noise. Also, protect the scanner  
against any static electricity, which can  
cause the scanner to malfunction.  
Do not block the ventilation ports. Blocking  
the ventilation ports generates heat inside  
of scanner, which may result in fire or  
scanner failure.  
Do not place heavy objects or climb  
on top of the scanner.  
Do not use aerosol sprays near the  
scanner.  
Do not place heavy objects on the scanner  
or use the scanner's surface top to perform  
other work. Improper installation might  
cause injuries and equipment failure.  
Do not use aerosol sprays to clean the  
scanner. Aerosol sprays can blow dirt and  
dust inside the scanner, resulting in scanner  
failure or malfunction.  
Firmly insert the power plug.  
Disconnect the power plug from the  
power outlet when the scanner is not  
used for a long period of time.  
Firmly insert the power plug as far it can go  
into the power outlet.  
When the scanner is not going to be used  
for a long period of time, be sure to  
disconnect the power plug from the power  
outlet for safety.  
Avoid any contact when scanner is in  
use.  
Avoid touching any scanner mechanism  
during scanning since this may cause  
injuries.  
Do not install the scanner in the  
direct sunlight.  
Do not install the scanner under direct  
sunlight or near heating apparatus. Doing  
so might cause excessive heat to build up  
inside the scanner, which can cause  
scanner trouble or even fire. Install the  
scanner in a well-ventilated location.  
Do not use the scanner immediately  
after moving it from a cold place into  
a warm room.  
Do not use the device immediately after  
moving it from a cold place into a warm  
room. Condensation may occur, which  
might lead to scanning errors. Let the  
device dry about one or two hours before  
you use it.  
Before moving the scanner, make  
sure the shipping lock is locked.  
When moving the scanner, be sure to lock  
the shipping lock in order to prevent  
damages to the scanner.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter1 PREPARING THE SCANNER  
Inside  
1.1 Checking the Contents of  
the Scanner Package  
[fi-5220C]  
When you open the scanner package, please handle the  
main unit and its attachments carefully.  
Document cover  
Make sure it contains all the parts listed in the package  
contents list that is included in the package box.  
If any parts are missing or defective, contact the dealer  
you purchased the scanner or an authorized Fujitsu scan-  
ner service provider. Handle the scanner and accessories  
with care.  
Document holding pad  
Document bed  
1.2 Names and Functions of  
Parts  
This section describes the scanner parts and their func-  
tions.  
Shipping lock  
(located on base)  
Front  
Rear  
[fi-5120C]  
[fi-5120C]  
ADF paper chute  
Side guide  
Automatic document  
feeder (ADF)  
ADF button  
5
0
Operator panel  
DC inlet  
Security  
Slot  
SCSI ID  
switch  
USB Interface  
connector  
EXT connector  
(For Imprinter  
connection)  
Stacker  
SCSI Interface  
connector  
[fi-5220C]  
[fi-5220C]  
ADF paper chute  
Side guide  
ADF (Automatic  
document feeder)  
ADF button  
Flatbed  
Operator panel  
Stacker  
Security  
Slot  
SCSI ID  
switch  
DC inlet  
SCSI Interface connector  
USB Interface connector  
fi-5120C/fi-5220C Image Scanner Getting Started  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Removable Parts  
Name  
Function  
Parts that can be removed from the scanner are dis-  
played below.  
Function Number display  
Indicates the function Num-  
ber and error status.  
Buttons  
Function  
Changes the Function acti-  
vated by the Send to button  
(*).  
ADF paper chute  
Can be  
removed  
Pick roller  
Send to  
Launches the linked applica-  
tion software (*).  
Scan  
Power button  
Turns the scanner ON and  
OFF.  
Pad ASSY  
Sheet guide  
LED  
-
Lights when the scanner is  
turned ON.  
[fi-5220C only]  
Document cover  
*) About the settings on the launcher, refer to FUJITSU  
TWAIN32 scanner driver help and the "fi-5120C/fi-  
5220Cfi-5120C/fi-5220C Operator’s Guide" in the Setup  
CD-ROM.  
Indications on the Function  
Number Display  
No.  
8
Descriptions  
Lights only one time upon turning on the scanner.  
Indicates that the scanner has been turned ON and  
is being initialized.  
P
1.3 Operator Panel  
Indicates that initialization will soon be completed.  
0
1
The operator panel is located on the right side of the  
scanner. This panel comprises of a Function Number  
display, four buttons and a LED.  
Indicates that initialization has been completed  
successfully.  
This status is called "Ready Status".  
Indicates that a temporary error occurred when  
documents were being scanned. A number appear-  
ing in alternation following the U (i.e., 1 or 2, etc.)  
refers to the type of error.  
U
Function  
Number  
display  
To return the scanner to the ready status ("1"),  
press "Scan" or "Send to" button.  
Function  
Indicates that a device (hardware) alarm has  
occurred during scanning of documents.  
"E" and the alarm Number (0 to 9, A,c,d and F)  
will appear alternately.  
E
Send to  
Scan  
To return the scanner to the ready status ("1"),  
press "Scan" or "Send to" button.  
Power button  
If this alarm occurs, turn the power off and on  
again. If the alarm continues after turning the  
power on again, contact your service engineer.  
LED  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter2 INSTALLATION OF THE SCANNER  
ADF paper chute  
2.1 Installing the Scanner  
1. Place the scanner at its installation site.  
Tab  
For details on the scanner's dimensions and  
required installation space, refer to "fi-5120C/fi-  
5220C Operator’s Guide" "7.2 Installation Speci-  
fications" in the Setup CD-ROM.  
For fi-5120C, go to Step 3.  
2. Unlock the Shipping lock.  
The carrier unit inside the scanner is fixed in  
place by the shipping lock to prevent the scanner  
from becoming damaged during transportation  
from the factory.  
Side guide  
After transporting and placing the scanner, tilt the  
scanner (approx. 30 degrees) and release the  
Shipping lock on the bottom of the scanner.  
4. Connect the AC adapter.  
Use only the AC adapter provided by the  
manufacturer.  
ATTENTION  
Approx.30  
degrees  
1) Connect the AC cable to the AC adapter.  
Lock  
Release  
2) Connect the AC adapter connector to the scan-  
ner’s DC inlet.  
3. Attach the ADF paper chute.  
Hold the ADF paper chute and insert its tabs into  
the corresponding slots in the scanner as shown in  
the next figure below.  
The Side guides of the ADF paper chute have to  
face up.  
3) Plug the AC cable into the outlet.  
The Function Number Display and the LED  
may flash for an instant when plugging the  
AC cable into the outlet.  
HINT  
fi-5120C/fi-5220C Image Scanner Getting Started  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Connecting with the SCSI Inter-  
face Cable  
2.2 Connecting the Scanner to  
Your PC  
When using the scanner with SCSI interface, a commer-  
cially available SCSI interface cable and SCSI card must  
be purchased in addition.  
When running Windows 95 or Windows NT 4.0, con-  
nect the SCSI interface cable. When running Windows  
98, Windows Me, Windows 2000, or Windows XP, con-  
nect either the USB interface cable or the SCSI interface  
cable.  
SCSI interface cable:  
Use a connector which complies with Ultra  
SCSI. A 50 Pin Contact Shielded High-Density  
SCSI Device Connector is required.  
SCSI card:  
This scanner is provided with two inter-  
ATTENTION  
Find the recommended SCSI card information in  
the Fujitsu web site (FAQ).  
faces: Ultra SCSI and USB 2.0 /1.1. Con-  
nect only one of the USB or SCSI interface  
cable. Windows 95 and Windows NT 4.0  
do not support USB interface.  
When connecting the SCSI interface  
cable, turn the scanner off. Be sure to  
first connect the SCSI interface cable  
and, then turn on the power of the scan-  
ner and the personal computer.  
In a SCSI daisy chain formation, con-  
nect the scanner so that it is the termi-  
nated device.  
ATTENTION  
Connecting with the USB Interface  
Cable  
1. Connect the USB interface cable to the USB  
interface connector.  
1. Insert the SCSI interface cable into the inter-  
face connector until both sides click.  
2. Connect the other end of the USB interface  
cable to the PC.  
Be sure to use the USB cable which  
comes as an accessory with this scan-  
ner.  
Scanning operation with commercially  
available cables is not guaranteed.  
When connecting to an USB hub, use  
the first stage USB hub that is closest to  
the computer. If you use the second or  
later hub stages, the scanner may not  
operate correctly.  
ATTENTION  
2. Connect the other end of the cable to the per-  
sonal computer.  
Be careful not to bend the pins of the SCSI  
ATTENTION  
cable when connecting to the scanner .  
If you connect the scanner with USB 2.0,  
it is required that the USB port and Hub  
are compliant with USB 2.0. The scan-  
ning speed may slow down if it is con-  
nected with USB1.1.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
The factory default setting for SCSI ID is  
"5". If the SCSI ID of another SCSI device is  
set to the same ID, change either the scan-  
ner's SCSI ID or SCSI ID of the other SCSI  
device. Set the SCSI ID using the SCSI ID  
switch on the back of the scanner.  
Uninstall [Scanner Utility for Microsoft Win-  
dows] from [Add/Remove Programs] of the  
control panel.  
ATTENTION  
HINT  
There are two types of FUJITSU TWAIN 32:  
One of the following driver software will be  
installed automatically according to your Oper-  
ating System (OS).  
5
0
For Windows 98, Windows Me, Windows  
2000, and Windows XP:  
Click  
FUJITSU TWAIN32 V9  
For Windows 95, Windows NT 4.0:  
FUJITSU TWAIN32 V8  
2.3 Installing the Scanner  
Application  
ASPI Manager V4.01 or later is required  
(generally comes with SCSI board products).  
For scanning documents with this scanner, both scanner  
driver and image capturing application software (called  
"application" hereafter) must be installed on your PC.  
The following scanner drivers and applications are pro-  
vided:  
Installing the FUJITSU TWAIN32  
Scanner Driver  
Scanner Driver:  
Windows XP screenshots are used in this sec-  
tion as examples. The windows and opera-  
tions may slightly vary, if your OS is other than  
Windows XP.  
HINT  
FUJITSU TWAIN 32 Scanner Driver  
FUJITSU ISIS Scanner Driver  
Scanning application:  
ScandAll 21 (for FUJITSU TWAIN 32)  
QuickScan ProTM (for FUJITSU ISIS)  
1. Press the power button to turn on the scanner.  
2. Turn on your PC and log on to Windows.  
Install the appropiate scanner driver for the application  
you will use. The following sections descri be installa-  
tion of each driver and application.  
When using Windows NT 4.0, Windows  
ATTENTION  
2000 or Windows XP, log on as a user with  
"Administrator" privileges (privileges of the  
administrator of your PC).  
For FUJITSU TWAIN32 Scanner Driver  
Preparation  
3. If the scanner is automatically detected,  
[Found New Hardware Wizard] or [Add/  
Remove Hardware Wizard] dialog box will  
appear. Click [Cancel] to close the Wizard win-  
dow.  
Confirm the following items before installing the appli-  
cation.  
Take out the Setup CD-ROM from its pack-  
age, but do not insert the Setup CD-ROM  
into the CD driver yet.  
Connect the scanner correctly to your PC.  
For details on how to connect the scanner,  
HINT  
Uninstall any older versions of FUJITSU  
TWAIN 32 driver if already installed.  
fi-5120C/fi-5220C Image Scanner Getting Started  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4. Insert the Setup CD-ROM into the CD drive.  
8. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
<SETUP DISK START UP SCREEN>  
appears.  
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your PC is off. In this  
case, run "Install.exe" in this CD-ROM directly  
from the "Explorer" or "My Computer".  
5. Click [INSTALL PRODUCTS].  
9. Install the application following the instructions  
on the window.  
10. When the [InstallShield Wiizard Complete] win-  
dow appears, click [Finish].  
6. Click [TWAIN Driver] on the window below.  
Your computer will be restarted and the scanner will be  
detected. Do not remove the Setup CD-ROM from the  
CD drive until your PC has completely restarted.  
Depending on the OS, these operations  
ATTENTION  
may be necessary.  
For Windows 98:  
When a request for inserting the CD-ROM  
for Windows 98 appears, insert it into the  
CD drive and click the [OK] button.  
7. Error Recovery Guide Installation window  
appears.  
For Windows 2000:  
When [Digital Signature not Found]  
appears, click [Yes].  
Error Recovery Guide is a software that dis-  
plays troubleshooting information on screen  
when any scanner error occurs, and its installa-  
tion is highly recommended. However, it can  
be installed later if you do not install it in this  
step.  
Now the installation of the scanner driver is completed.  
To confirm whether the installation was  
ATTENTION  
successful, perform a scanning operation  
with an application that complies with the  
TWAIN regulations such as ScandAll 21.  
When you select [Yes] for installing the Error  
ATTENTION  
Recovery Guide, [Choose Setup Language]  
window appears. Select a language and fol-  
low the instructions on the window. Error  
Recovery Guide will automatically finish fin-  
ishing its installation. Please wait until the  
installation of TWAIN driver automatically  
starts.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Install the application following the instructions  
on the window.  
Installing ScandAll 21  
"Scandall 21" is an image capturing software that com-  
plies with the TWAIN standard.  
6. When the [InstallShield Wizard Complete] win-  
dow appears, click [Finish]  
When using Windows NT 4.0, Windows  
ATTENTION  
2000 or Windows XP, log on as a user with  
"Administrator" privileges (privileges of the  
administrator of your PC).  
1. Insert the Setup CD-ROM into the CD drive.  
<SETUP DISK START UP SCREEN>  
appears.  
2. Click [INSTALL PRODUCTS].  
For finishing the installation, it may be nec-  
ATTENTION  
essary to restart your computer. Follow the  
instructions on the window.  
Confirming Installation  
1. Set documents on the ADF paper chute.  
For details on how to set documents, refer to the  
"1.2 Loading Documents on the ADF for Scan-  
ning" in the fi-5120C/fi-5220C Operator’s Guide  
provided in the CD-ROM.  
3. Click [ScandAll 21] on the window below.  
2. Start ScandAll21  
Select [Start] - [Programs] - [Scanner Utility for  
Microsoft Windows] - [ScandAll 21].  
3. Specify the scanner (that you will use)  
Select [Select Source...] from the [Scan] menu of  
ScandAll 21.  
4. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
4. Select "FUJITSU fi-5120Cdj/fi-5220Cdj" or  
"FUJITSU TWAIN32" on the dialog box.  
fi-5120C/fi-5220C Image Scanner Getting Started  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
For Windows 98, Windows Me, Windows  
2000, Windows XP:  
HINT  
For FUJITSU ISIS Scanner Driver  
[FUJITSU fi-5120C/fi-5220Cdj]  
For Windows 95, Windows NT 4.0:  
[FUJITSU TWAIN32]  
Preparation  
Confirm the following items before installing the driver  
application.  
Take out the Setup CD-ROM from its pack-  
age, but do not insert the Setup CD-ROM  
into the CD driver yet.  
5. Select [To View...] from the [Scan] menu.  
6. Set scanning resolution, document size, etc. on  
the [TWAIN driver] window (for setting details  
of scanning) and click the [Scan] button.  
Connect the scanner correctly to your PC..  
For details on how to connect the scanner,  
HINT  
Installing the FUJITSU ISIS  
Scanner Driver  
Windows XP screenshots are used in this  
section as examples. The windows and  
operations may vary slightly, if your OS is  
other than Windows XP.  
HINT  
1. Press the power button to turn on the scanner.  
2. Turn your PC on and log on to Windows.  
For details on [TWAIN driver], refer to the  
"FUJITSU TWAIN32 Scanner Driver User’s  
Guide" provided on the Setup  
CD-ROM.  
HINT  
When using Windows NT 4.0, Windows 2000  
ATTENTION  
or Windows XP, log on as a user with  
"Administrator" privileges (privileges of the  
administrator of your PC).  
7. Documents are scanned, and the generated  
images are displayed on the [ScandAll 21] win-  
dow.  
3. If the scanner is automatically detected,  
[
Found New Hardware Wizard] or [Add/Remove  
Hardware Wizard] dialog box will appear. Click  
[Cancel] to close the Wizard window.  
If the scanning completes without any trouble, the  
installation performed successfully.  
For details on various types of scanning, refer to the "fi-  
5120C/fi-5220C Operator’s Guide" on the Setup CD-  
ROM.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Insert the "Setup CD-ROM" into the CD drive.  
8. Select a language used for installation on  
[Choose Setup Language] window and click  
[OK].  
<SETUP DISK START UP SCREEN>  
appears.  
This screen may not appear when the  
ATTENTION  
"Autoplay" setting of your PC is off. In this  
case, run "Install.exe" in this CD-ROM  
directly from the "Explorer" or "My Computer".  
9. Install the application following the instructions  
on the window.  
5. Click [INSTALL PRODUCTS].  
10. When the [InstallShield Wiizard Complete] win-  
dow appears, click [Finish].  
Your computer will be restarted and the scanner will be  
detected. Do not remove the Setup CD-ROM from the  
CD drive until your PC has completely restarted  
Depending on the OS, these operations may  
ATTENTION  
be necessary.  
For Windows 98:  
When a request for inserting the CD-ROM for  
Windows 98 appears, insert it into the CD  
drive and click the [OK] button.  
6. Click [ISIS Driver] on the window below.  
For Windows 2000:  
When [Digital Signature not Found] appears,  
click [Yes].  
Now the installation of the scanner driver is completed.  
Installing QuickScan Pro™  
"QuickScan Pro™" is an image capturing software that  
complies with the ISIS standard.  
When using Windows NT 4.0, Windows  
ATTENTION  
2000 or Windows XP, log on as a user with  
"Administrator" privileges (privileges of the  
administrator of your PC).  
7. Error Recovery Guide Installation window  
appears.  
Error Recovery Guide is a software that dis-  
plays troubleshooting information on screen if  
any scanner error occurs, and its installation is  
highly recommended. However, it can be  
installed later even if you do not install it in this  
step.  
1. Insert the Setup CD-ROM into a CD drive.  
<SETUP DISK STARTUP SCREEN>  
appears.  
When you select [Yes] for installing Error  
ATTENTION  
Recovery Guide, the [Choose Setup Lan-  
guage] window appears. Select a lan-  
guage and follow the instructions on the  
window. The Error Recovery Guide will  
automatically finish its installation. Please  
wait until the installation of TWAIN driver  
automatically starts.  
fi-5120C/fi-5220C Image Scanner Getting Started  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Click [INSTALL PRODUCTS].  
5. Enter the required information, then click [Next  
>] button.  
3. Click [QuickScan PRO (Trial)] on the window  
below.  
"QuickScan Pro™" included in the Setup  
ATTENTION  
CD-ROM is a Trial version. For further use  
after the expiration of its evaluation period  
of up to 30 launches, it is necessary to pur-  
chase a fully functional version of Quick-  
Scan Pro™. (When you install the  
evaluation version, do not change the  
Serial Number already displayed.)  
6. Install the application following the instructions  
on the window.  
Confirming Installation  
1. Load the documents on to the scanner.  
4. Continue to install the application following the  
instructions on the window.  
For details on loading documents, refer to "1.2  
Loading Documents on the ADF for Scanning" in  
the fi-5120C/fi-5220C Operator’s Guide on the  
Setup CD-ROM.  
2. Start QuickScan Pro™.  
From the [Start] menu select [Programs]-[Quick-  
Scan]-[QuickScan].  
3. Select [Select Scanner...] from [Scan] menu in  
QuickScan Pro™.  
And select fi-5120C/fi-5220C from the list of  
[Scanner:], and then click the [OK] button.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Select [Preview Settings...] from the [Scan]  
menu. Set the scan resolution, paper size and  
other scanning requirements, and then click  
[OK].  
Error Recovery Guide  
The Error Recovery Guide is a software that displays  
troubleshooting information on screen if any scanner  
error occurs.  
If you did not install the Error Recovery Guide when  
installing the scanner driver, install it following the pro-  
cedure below.  
1. Insert the Setup CD-ROM in your CD drive.  
The <SETUP DISK STARTUP SCREEN> will be  
displayed.  
2. Click [Install Products].  
5. Select [Preview Scan] from the [Scan] menu.  
And then the document is scanned.  
3. Click [Error Recovery Guide] on the next screen.  
If the scanning completes without any trouble, the  
installation performed successfully.  
Refer to "QuickScan Overview" or "Quick-  
HINT  
Scan Help" for information about Quick-  
Scan Pro™ functions and operations. On  
the [Start] menu, point to [Programs]-  
[QuickScan] and click the file.  
4. Select a language to use for the installation in  
the <Choose Setup Language> window and  
click [OK].  
5. Install the application following the instructions  
in the window.  
fi-5120C/fi-5220C Image Scanner Getting Started  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. When the [InstallShield Wizard Complete]  
screen displays, click [Finish].  
This window is not displayed automatically  
when the "Auto play" setting of your com-  
puter is deactivated. In this case, please  
run "Auto play.exe" of this CD-ROM  
directly using the "Explore" or "My com-  
puter".  
ATTENTION  
2. Select the language and Click [OK] button.  
Image Processing Software Option  
(Trial)  
For details on the installation of the Image Processing  
Software Option, refer to the "Image Processing Soft-  
ware Option USER’S GUIDE".  
3. Select "Install Adobe Acrobat".  
®
®
Adobe Acrobat  
Install Adobe Acrobat from the "Adobe Acrobat CD-  
ROM" provided with this scanner.  
Adobe Acrobat is not supported by  
ATTENTION  
Microsoft Windows 95, Microsoft Win-  
dows 98/98 Second Edition, Microsoft  
Windows NT4.0, and Microsoft Windows  
Me.  
Adobe Acrobat is required for displaying  
HINT  
the manuals stored in the CD-ROM.  
4. Click the [Next] button. The set up window  
appears.  
* Installation of Adobe Acrobat is not nec-  
essary if it has already been installed in  
your PC.  
1. Insert the "Adobe Acrobat CD-ROM" into the  
CD-ROM drive.  
The "Adobe Acrobat - Setup" window  
appears.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Followtheinstructionstoinstallthesoftware.  
Uninstalling Supplied Programs  
Follow the procedure below to uninstall supplied pro-  
grams.  
Select "How to install" on the "Adobe Acro-  
bat" window to learn more about Adobe  
HINT  
Acrobat installation. Refer to "Adobe Acro-  
bat Help" about how to use Adobe Acrobat.  
Windows XP screenshots are used in this sec-  
HINT  
tion as examples. The windows and opera-  
tions may slightly vary, if your OS is other than  
Windows XP.  
Notes for using Adobe Acrobat  
ATTENTION  
When scanning a paper document and  
converting the image to PDF using Adobe  
Acrobat, unexpected images may be out-  
put when:  
1. Start up your PC.  
1. Setting "Edge Shadow Removal" in Acro-  
bat, and setting "Digital Endorser" or  
"Black Background" options in the  
TWAIN driver at the same time. Letter  
strings embedded in the image or the  
background may be missed.  
When using Windows NT 4.0, Windows  
ATTENTION  
2000 or Windows XP, log on as a user with  
"Administrator" privileges (privileges of the  
administrator of your PC).  
Solution 1: Set "Edge shadow removal"  
to "OFF" or set any option other than  
"Adaptive" for "Color/Grayscale" and/or  
"Monochrome" under "Compression" by  
selecting [File]->[Create PDF]-> [From  
Scanner...]-> [Image Settings...] in Acro-  
bat.  
2. Exit all currently running programs.  
3. Select [Control Panel] - [Add or remove Pro-  
grams] from the [Start] menu.  
This displays the "Add or remove Programs"  
screen which displays a list of the currently  
installed applications.  
Solution 2: Adjust the scanning density  
in the TWAIN driver.  
2. Setting "Adaptive" for "Color/Grayscale"  
and/or "Monochrome" under "Compres-  
sion" in Acrobat and scanning in a reso-  
lution lower than the resolution  
recommended for Acrobat.  
4. Select the application to uninstall.  
When uninstalling FUJITSU TWAIN 32  
scanner driver,  
Solution: Set OPTION to something  
other than "Adaptive" under "Compres-  
sion."  
select "Scanner Utility for Microsoft Win-  
dows".  
When uninstalling ScandAll 21,  
select "ScandAll 21".  
3. Scanning a document longer than the  
double letter (11x17) or A3 size, when  
setting "Overscan" in the TWAIN driver,  
the scan may fail.  
When uninstalling FUJITSU ISIS scanner  
driver,  
Solution: When scanning a double letter  
(11x17) or A3 size of document, do not  
set "Overscan" in TWAIN driver.  
select "Fujitsu ISIS Drivers".  
When uninstalling QuickScan ProTM,  
select "QuickScan 3.0".  
*As for detailed usage and information of  
Acrobat, refer to "Create a PDF file from a  
scanned document" in Acrobat Help.  
When uninstalling Error Recovery Guide,  
select "Error Recovery Guide".  
When uninstalling Software Operation  
Panel,  
Support and User registration for Adobe  
products  
select "Software Operation Panel".  
ATTENTION  
Refer to the technical support information  
stored in the [Customer Support] folder on  
Adobe Acrobat CD-ROM. (Note that free  
person-to-person support is not available  
for this is bundled product.)  
When uninstalling Image Processing  
Software Option, refer to "Image Pro-  
cessing Software Option Operation  
Guide".  
ATTENTION  
When uninstalling Adobe Acrobat, refer  
to the installation procedure described in  
the Adobe Acrobat CD-ROM.  
fi-5120C/fi-5220C Image Scanner Getting Started  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Click the [Change/Remove] or [Remove] but-  
ton.  
6. When the confirmation dialogbox appears,  
Click the [OK] or [Yes] button.  
This executes the uninstallation.  
Screen displays may vary slightly accord-  
ATTENTION  
ing to the operation system (OS) you are  
using. Follow the on screen instructions of  
the OS.  
Example: When the OS Windows 2000  
"Add or Remove Programs" - "Add/  
Remove Applications"  
[Changel/Remove] button - [Add/  
Remove] button.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix1 TROUBLESHOOTING  
Troubleshooting checklist  
Symptom  
Check this item  
Remedy  
Scanner does not turn on.  
Have you pressed the power button on?  
Push the power button in to turn the scanner.  
Are the AC cable and AC adapter prop-  
erly connected to the  
Correctly connect the AC cable and the AC  
adapter.  
scanner?  
Disconnect the AC cable and the AC adapter from  
the scanner, then connect them again.  
If this does not restore the power supply, contact  
the store where you purchased the scanner or an  
authorized FUJITSU scanner service provider.  
Are you using the correct AC cable and  
AC adapter supplied with the scanner  
from the manufacture?  
You must use the AC adapter and cable supplied  
with your scanner by the  
manufacture. Please get the correct AC adapter  
and cable to connect to your scanner.  
Scanning does not com-  
mence.  
Are the documents loaded properly on to Realign and reload the documents on to ADF  
the ADF paper chute?  
paper chute.  
Is the ADF closed completely?  
Close the ADF completely.  
Is the USB cable or SCSI cable con-  
nected securely?  
Connect the cable. (When a USB hub is used,  
check the hub's power supply.)  
When using a SCSI interface, Is SCSI  
ID set correctly?  
Use the SCSI ID switch at the rear of the scanner  
to set the SCSI ID.  
Does the Function Number display indi- When the Function Number display indicates an  
cates an alarm or an error?  
alarm or an error, refer to the "Chapter 5. TROU-  
BLESHOOTING" in the fi-5120C/fi-5220C  
Operator’s Guide for removing the alarm or the  
error.  
The alarm status remain displayed even  
Turn off and on the power button.  
after the scanner has been turned off and If this does not eliminate the alarm status, contact  
on again?  
the store where you purchased the scanner or an  
authorized FUJITSU scanner service provider.  
Vertical lines appear in the  
generated image of the  
scanned document.  
Are the glass dirty?  
Clean the glass as instructed in the Operator's  
Guide "3. Daily Care".  
The generated image shifts  
or is distorted.  
Are the documents loaded correctly?  
Are the glass clean?  
Load the documents correctly.  
Clean dirty locations.  
Quality of generated image  
is unsatisfactory.  
Multi feed frequently  
occurs.  
Do the documents satisfy the "Docu-  
ment Quality" and the "Multi feed  
Detection Conditions" in the chapter 6  
of the fi-5120C/fi-5220C Operator’s  
Guide?  
Use the documents that satisfy the "Document  
Quality" and the "Multi feed Detection Condi-  
tions" in the chapter 6 of the fi-5120C/fi-5220C  
Operator’s Guide.  
Are the documents placed properly in  
the ADF paper chute?  
Fan the documents before scanning. Correctly  
align the document stack and load them on the  
ADF paper chute. Refer to "2.1 Installing the  
Is the stack of document thicker than 5  
mm?  
Reduce the number of sheets of the stack to a  
thickness of 5 mm or less.  
Is the Pad ASSY dirty?  
Clean the Pad ASSY. Refer to Operator's Guide in  
"3.3. Cleaning the ADF".  
Is the Pad ASSY worn out?  
Replace the Pad ASSY. Refer to Operator's Guide  
in "4.2. Replacing the Pad ASSY".  
fi-5120C/fi-5220C Image Scanner Getting Started  
AP-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Symptom  
Check this item  
Remedy  
Paper is not fed (pick error  
occurs frequently, or docu-  
ment stops midway).  
Do the documents satisfy the "Docu-  
ment Quality" and the "Multi feed  
Detection Conditions" in the chapter 6  
of the fi-5530C Operator’s Guide?  
Use the documents that satisfy the "Document  
Quality" and the "Multi feed Detection Condi-  
tions" in the chapter 6 of the fi-5530C Operator’s  
Guide.  
Is the Pick roller dirty?  
Clean the Pick roller. Refer to Operator's Guide in  
"3.3. Cleaning the ADF".  
Is the Pick roller worn out?  
Change the Pick roller. Refer to Operator's Guide  
in "4.3. Replacing the Pick Roller".  
Is there any dirt or dust in the document Remove any dirt or dust from the document feed  
feed path?  
path.  
The generated images are  
elongated.  
Are the Feed rollers dirty?  
Clean the Feed rollers. Refer to Operator's Guide  
in "3.3. Cleaning the ADF".  
Have you adjusted the scan scale?  
For Windows 98, Windows Me, Windows 2000,  
WindowsXP, select "Scanners and Cameras" in  
the control panel, then click the [Device Set] tab  
to adjust scale.  
For Windows 95, Windows NT 4.0, right click the  
Scanner Control Center in the task tray, select  
[Options] and adjust the scan scale.  
There is a shadow on the  
leading edge of the gener-  
ated image.  
Are the Feed rollers dirty?  
Clean the Feed rollers. Refer to Operator's Guide  
in "3.3. Cleaning the ADF".  
Have you adjusted the offset (the scan-  
ning starting position)?  
For Windows 98, Windows Me, Windows 2000,  
WindowsXP, adjust the [Sub-scan Setting] on  
[Scanners and Cameras] in the control panel.  
For Windows 95, Windows NT 4.0, right click the  
Scanner Control Center, select [Options]-[Sub-  
scan Setting] and adjust the offset.  
AP-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Temporary error  
Device alarm (Non-Temporary  
error)  
Indication  
Meaning  
Indication  
E0  
Meaning  
U0  
U1  
U2  
U4  
U6  
Shipping lock error (fi-5220C)  
Paper feed error  
Flatbed motor malfunction.  
E1  
Trouble in the optical system  
(Flatbed).  
Multi feed error  
The ADF cover is opened.  
Print cartridge not installed (fi-5120C)  
E2  
E3  
E4  
E6  
E7  
Trouble in the optical system (front).  
Trouble in the optical system (back).  
The motor’s fuse has blown out.  
Trouble in the operator panel.  
To troubleshoot the indicated errors above:  
"U0" error  
Trouble occurred in the internal memory  
(EEPROM).  
Confirm that the shipping lock is released.  
E8  
E9  
EA  
Ec  
Ed  
The SCSI interface fuse has blown out.  
An error in the image memory.  
Trouble with the Imprinter.  
"U1" error  
Remove all jammed documents.  
Confirm that the documents meet the paper con-  
ditions for scanning.  
Refer to fi-5120C/fi-5220C Operator’s Guide "5.  
Troubleshooting" on the Setup CD-ROM.  
An alarm in the memory.  
Trouble with the SCSI interface control-  
ler.  
EF  
"U2" error  
Trouble with the background switching  
mechanism.  
Remove all jammed documents.  
Confirm that the documents are within the  
required paper preconditions for scanning.  
Refer to fi-5120C/fi-5220C Operator’s Guide  
"6.2 Document Quality" on the Setup CD-ROM.  
When you encounter any alarm on the display, turn the  
scanner off and on. If the alarm is still displayed on the  
Function Number display, contact the store where you  
purchased the scanner or an authorized FUJITSU scan-  
ner service provider.  
"U4" error  
Close the ADF cover completely. For the details,  
refer to "5 TROUBLESHOOTING" in the "fi-  
5120C/fi-5220C Operator's Guide" on the Setup  
CD-ROM.  
"U6" error  
This is a temporary error related with the  
Imprinter option (sold separately). Refer to fi-  
512PR Operator’s Guide "5 Error Message".  
fi-5120C/fi-5220C Image Scanner Getting Started  
AP-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix2 DAILY CARE  
Parts to Clean and When  
The glass surface inside the  
ADF becomes hot during the  
operation.  
Before you clean inside the  
scanner, turn off its power and  
unplug the AC adapter from the  
outlet. Wait for at least  
15 minutes.  
Part to clean  
Pad ASSY  
Standard Cleaning Cycle  
Clean these parts after every  
1,000 scans.  
Pick roller  
Feed rollers  
Plastic rollers  
Glass  
Do not turn off the scanner when  
you clean the Feed rollers.  
Cleaning Materials  
The scanner must be cleaned frequently  
if you scan any of the following type of  
paper sheets:  
ATTENTION  
Cleaning  
Materials  
Parts  
Number  
Remarks  
1 bottle  
Moisten the cloth with  
this fluid and wipe the  
scanner clean. (*)  
Documents of coated paper  
Cleaner F1  
(or isopropyl  
alcohol)  
CA99501-  
0013  
Documents that are almost completely  
covered with printed text or graphics  
Chemically treated documents such as  
carbonless paper  
Lint-free dry  
cloth  
Commercially available one  
Documents containing a large amount  
of calcium carbonate  
Handwritten documents  
* For details about cleaning materials, contact the  
FUJITSU scanner dealer where you purchased the  
scanner.  
For details on the cleaning the ADF, refer to "3.3 Clean-  
ing the ADF" in fi-5120C/fi-5220C Operator’s Guide on  
the Setup CD-ROM".  
Cleaning Method  
The ADF must be cleaned with a lint-free cloth moist-  
ened with the Cleaner F1.  
AP-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix3 REPLACING CONSUMABLES  
The illustration below demonstrates the locations of the  
The glass surface inside the  
ADF becomes hot during the  
operation. Before replacing the  
consumables, turn its power off  
and unplug the AC adapter from  
the outlet. Wait at least 15 min-  
utes.  
replacement parts. Refer to "Chapter 4 Replacing Con-  
sumables" fi-5120C/fi-5220C Operator’s Guide on the  
Setup CD-ROM.  
Replacing the Pad ASSY  
Consumables and Replacement  
Cycles  
Below are specifications of consumable items and  
their recommended replacement cycles.  
Replacing the Pick Roller  
Parts  
Number  
Standard  
Replacement Cycle  
Description  
Pad ASSY  
PA03289-  
0111  
After 50,000 scans or  
one year  
Pick Roller  
Pick roller  
PA03289-  
0001  
After 100,000 sheets  
or one year  
To purchase consumables, contact the store where you  
purchased the scanner or an authorized FUJITSU scan-  
ner service provider.  
The replacement cycles above are rough guidelines  
when using A4 or Letter woodfree or wood containing  
paper 64 g/m2 (17 lb). This cycle varies according to the  
type of paper and how frequently the scanner is used and  
cleaned.  
Use only above specified consumables.  
ATTENTION  
Do not use other consumables.  
Pick Roller's Shaft  
fi-5120C/fi-5220C Image Scanner Getting Started  
AP-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
fi-5120C/fi-5220C Image Scanner Getting Started  
P3PC-1312-02EN  
Date of issuance: June 2006  
Issuance responsibility: PFU LIMITED  
z Copying of the contents of this manual in whole or in part and  
copying of the scanner application is forbidden under the copyright  
law.  
z The contents of this manual are subject to change without notice.  
z PFU LIMITED. is not liable whatsoever for any damages resulting  
from use of this scanner and procedures described in this manual,  
profit due to defects, and any claims by a third party.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Earthquake Sound Speaker TNT 10DVC User Manual
Echo Trimmer GT 230 User Manual
Electro Voice Speaker EVH 1152S 43 User Manual
Electro Voice Speaker T180 User Manual
Extron electronic Stereo Amplifier CVDA 6 EQ MX User Manual
Fisher Price Motorized Toy Car T5407 User Manual
Franke Consumer Products Cooktop 4GAV TC User Manual
Gardena Water Pump D 89070 Ulm User Manual
GE Microwave Oven 39 40425 User Manual
Glem GasEmilia Cooktop FC74GSWI User Manual