Shortening Disposal Unit (SDU)  
Installation, Operation, Service, and Parts Manual  
TABLE OF CONTENTS  
Page  
1
1. INTRODUCTION  
1.1 Service Information and Parts Ordering ..............................................1  
1.2 Installation, Operating and Service Personnel .....................................1  
1.3 Definitions ................................................................................................1  
1.4 Shipping Damage Claim Procedure ......................................................2  
1.5 What To Do If Your Equipment Arrives Damaged.............................2  
2. ASSEMBLY AND OPERATION ..........................................................2  
2.1 Equipment Description...........................................................................2  
2.2 Equipment Assembly ..............................................................................3  
2.3 Equipment Operation .............................................................................3  
2.4 Cleaning....................................................................................................5  
3. SERVICE PROCEDURES.....................................................................5  
3.1 General .....................................................................................................5  
3.2 Replacing Worn or Damaged O-Rings..................................................5  
3.3 Replacing Worn Pump Vanes and/or Pump Shaft Seal ......................5  
4. PARTS LIST............................................................................................7  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHORTENING DISPOSAL UNIT  
(SDU 100, 90 50, AND BKSDU)  
INSTALLATION, OPERATION, SERVICE AND PARTS  
1. INTRODUCTION  
1.1 Service Information and Parts Ordering  
Included with the unit when shipped from the factory is a list of Factory Authorized Servicers  
(FAS). Refer to this list to find the FAS nearest you. If you do not have access to this list, contact  
the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711.  
Service information may be obtained by contacting your local FAS. Information may also be  
obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-  
1711 or by e-mail: [email protected]. In order to assist you as quickly as possible, the FAS or  
Service Department representative requires certain information about your equipment. The  
information is printed on a data plate located on the tank cover. When requesting service, please  
have the following information ready:  
Model Number:  
Serial Number:  
In addition to the model number, and serial number, please be prepared to describe the nature of the  
problem and have ready any other information that you think may be helpful in solving your  
problem. Parts orders may be placed directly with your local FAS or distributor. When ordering  
parts, the following information is required:  
Model Number:  
Serial Number:  
Item Part Number:  
Quantity Needed:  
RETAIN AND STORE THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE USE.  
1.2 Installation, Operating and Service Personnel  
Installation, Operating, and Service information for this equipment has been prepared for use by  
qualified and/or authorized personnel only, as defined in Section 1.3.  
1.3 Definitions  
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL  
Qualified/authorized operating personnel are those who have carefully read the information in this  
manual and have familiarized themselves with the equipment functions, or who have had previous  
experience with the operation of the equipment covered in this manual.  
QUALIFIED SERVICE PERSONNEL  
Qualified service personnel are those who are familiar with this equipment and who have been  
authorized by Frymaster L.L.C. to perform service on equipment manufactured by Frymaster. All  
authorized service personnel are required to be equipped with a complete set of service and parts  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
manuals, and to stock a minimum amount of parts for Frymaster equipment. A list of Factory  
Authorized Service Centers (FASs) was included with this equipment when shipped from the  
factory. Unless specifically indicated otherwise in this manual, failure to use qualified service  
personnel will void the Frymaster Warranty on this equipment.  
1.4 Shipping Damage Claim Procedure  
This equipment was carefully inspected and packed before leaving the factory. The transportation  
company assumes full responsibility for safe delivery upon acceptance of the equipment for  
transport.  
1.5 What to Do If Your Equipment Arrives Damaged  
1. File a claim for damages immediately, regardless of the extent of damages.  
2. Inspect for and record all visible loss or damage and ensure that this information is noted on  
the freight bill or express receipt and is signed by the person making the delivery.  
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be  
recorded and reported to the freight company or carrier immediately upon discovery. A  
concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that  
the shipping container is retained for inspection.  
FRYMASTER DOES NOT ASSUME RESPONSIBILITY  
FOR DAMAGE OR LOSS INCURRED IN TRANSIT.  
2.  
ASSEMBLY AND OPERATION  
2.1 Equipment Description  
The Shortening Disposal Unit (SDU) is designed for the safe transportation of used shortening or  
cooking oil from the kitchen to a disposal container. There are three sizes –SDU 50 (50 lbs./23 kg),  
SDU 90 (90 lbs./41 kg) and SDU 100 (100 lbs./45kg). All sizes are similar in construction and  
operation. The units consist of a tank and a heavy-duty manual pump. All models are equipped with  
6 " (150 mm) wheels.  
The BKSDU is equipped with a 120VAC or 240VAC tank heater to prevent solid shortening from  
solidifying prior to disposal. The BKSDU is equipped with a receptacle that accepts a three-prong,  
grounded plug for protection against shock hazard. The power cord should be plugged directly into  
a properly grounded, three-hole wall or floor receptacle. Do not cut off, remove, or otherwise  
bypass the grounding prong on the power cord plug. CAUTION: Risk of fire and electric shock.  
Replace only with manufacturer’s cord set, part number 8071224 for 120V or part number  
106-4697 for 240V.  
With the cover open, the top of the tank is 9¾ inches (248 mm) above the floor, permitting it to be  
positioned directly beneath the drains of most fryers.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Equipment Assembly  
Assembly of the unit is a four-step process:  
1. Remove the two bolts from the handle-mounting bracket and raise the handle to the upright  
position. Reinstall the bolts in the bracket and tighten to 8 ft/lbs.  
2. Ensure the O-rings and the bottom 2 inches of the suction tube are lubricated with Accrolube  
with Teflon or an equivalent light oil or grease.  
3. Turn the pump and suction tube upside down and carefully pour no more than one cup of  
cooking oil down the tube. Rotate the pump handle slowly three or four times to prime the  
pump.  
4. Insert the suction tube through the pipe bracket on the handle and into the pickup tube on top of  
the reservoir. Push down on the pump assembly and ensure the suction tube is fully seated.  
2.3 Equipment Operation  
WARNING  
DO NOT use this unit to dispose of water or Boil-out solution. Introduction of water  
or solvents into the unit will permanently damage the pump.  
1. Turn the fryer off prior to draining into SDU. If so equipped, ensure the fryer drainpipe is firmly  
threaded into the frypot drain valve.  
2. Open the cover, verify that the crumb screen and rubber gasket on the inside cover are in place,  
and position the unit so that the opening is directly under the frypot drainpipe.  
Cover Gasket  
Crumb Tray  
DANGER  
Before each use inspect the cover to ensure the cover gasket is present and  
properly placed. DO NOT use the disposal unit if this gasket is damaged or  
missing.  
3. Slowly open the drain valve. Regulate flow with the drain valve to prevent splashing.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
DO NOT OVERFILL! Do not fill the reservoir above the fill lines on the sides of the  
reservoir. Moving the SDU with an overfilled reservoir may result in spills and injury  
to personnel who come in contact with the spilled shortening.  
4. Carefully withdraw the unit far enough to allow the cover to be closed. Latch the cover in the  
closed postion. Using the handle, carefully tip the unit back slightly for ease of handling and roll  
the unit to the disposal site.  
WARNING  
DO NOT use the pump or discharge piping assembly as a handle!  
DANGER  
To minimize the potential for burns, oil must always be allowed to cool below 100°F  
(38°C) before draining into the SDU and transporting to the disposal area. However,  
DO NOT allow shortening to solidify in the SDU.  
The unit is designed to be moved, when properly filled, at an average walking pace on a flat  
surface. Care must be taken at all times when moving hot shortening or oil. Rough terrain or  
sudden stops and starts may cause the contents of the reservoir to spill or splash out of the  
reservoir, possibly causing serious injury to personnel. Always ensure that the cover is latched  
shut when moving the unit.  
5. At the disposal site, lift the pump assembly lock pin and rotate the discharge pipe as necessary to  
position the discharge nipple over the opening of the disposal container. Release the lock pin to  
secure the pump assembly in position. Turn the pump handle clockwise. The pump should start  
discharging oil after a few turns. Continue turning the handle until the MSDU reservoir is empty.  
6. On BKSDU units, the built-in heater may be connected to a grounded 120VAC or 240VAC  
receptacle to prevent shortening from solidifying in the tank when immediate transfer to a  
disposal container is not possible.  
2.4 Cleaning  
Clean the crumb screen with a solution of detergent and water. Clean the exterior surfaces of the  
SDU with a soft cloth and a solution of detergent and water. It is not necessary to clean the interior  
of the reservoir, but if desired it may be wiped down with clean paper towels to remove excess  
residual shortening.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
DO NOT clean the interior of the reservoir with water or detergent. Introduction of  
water or detergent into the unit will permanently damage the pump.  
3. SERVICE PROCEDURES  
3.1 Introduction  
Other than routine cleaning and the replacement of worn suction tube O-rings, the SDU is  
maintenance free. After long use, the pump vanes and pump shaft seal may require replacement due  
to wear. Frymaster recommends worn pump vanes and/or pump shaft seals be replaced by an FAS,  
but store personnel may perform these service actions without voiding the warranty.  
3.2 Replacing Worn or Damaged O-Rings  
If pump efficiency degrades, it is likely that the O-rings on the suction tube are worn or damaged.  
To replace the O-rings, follow the steps below.  
1. Lift the pump assembly straight up and out of the handle assembly.  
2. Remove the worn or damaged O-rings from the grooves at the bottom of the suction tube and  
replace with new O-rings. Apply Accrolube with Teflon grease or equivalent to bottom 2 inches  
of the suction tube.  
3. Insert the suction tube through the tube bracket in the handle and into the receiver on top of the  
reservoir. Push down on the pump assembly to make sure the suction tube is fully seated.  
3.3 Replacing Worn Pump Vanes and/or Pump Shaft Seal  
Depending upon the amount of use, the vanes in the pump assembly will eventually wear, reducing  
the efficiency of the pump. The pump shaft seal can also become worn and start to leak. A kit for  
replacing the vanes and the seal is available. The pump shaft seal can also be purchased as a  
separate item. To replace the pump vanes, and/or the pump shaft seal, follow the steps below (refer  
also to the illustration on Page 6).  
1. Loosen the setscrew securing the pump handle to the pump shaft and slip the handle off the shaft.  
If unit is a BKSDU remove the eight screws that secure the pump cover in place and remove the  
cover.  
2. Remove the five screws securing the front cover and remove the cover.  
If replacing the pump shaft seal only, remove the old seal and install the replacement as shown in  
the illustration below, then go to Step 5.  
If replacing the pump vanes, go to Step 3.  
3. Grasp the pump shaft and carefully pull the rotor assembly straight out of the pump housing far  
enough to expose the vanes. IMPORTANT: The vanes are spring-loaded. Use one hand to  
hold the vanes while pulling the rotor assembly the rest of the way out of the housing. Carefully  
release the vanes and discard the worn vanes, springs, and rods.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Pump shaft seal fits into the  
recess of the pump cover.  
Step 5 - Replace gasket.  
Step 1 - Loosen  
setscrew and  
remove handle.  
Step 3 - Grasp  
shaft and pull  
rotor assembly  
out of housing.  
Step 4 - Replace  
vanes, spring,  
and rod.  
Step 2 - Remove cover  
screws and cover.  
4. Assemble the replacement vanes, spring and rod into the rotor assembly. Compress the vane  
spring and carefully insert the rotor assembly back into the pump housing.  
5. Position the replacement gasket on the pump body, slip the cover over the shaft, and align the  
pins in the cover with the holes in the pump housing. Reinstall the five screws removed in Step  
2 and tighten securely (torque to approximately 60 inch-pounds).  
6. Slip the pump handle back onto the shaft and align the screw hole in the handle with the screw  
hole in the shaft. Tighten the setscrew loosened in Step 1 securely.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. PARTS LIST  
10  
9
11  
8
7
6
SDU 50, 90, 100 and  
BKSDU units built April  
2010 and later.  
12  
5
4
13  
14  
15  
16  
3
17  
2
1
18  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
Part #  
Component  
1
2
3
4
*
5
6
7
8
9
10  
*
*
*
*
*
11  
*
12  
810-3784  
809-0200  
809-1001  
823-2421  
823-2038  
810-0777  
810-3858  
813-0032  
810-0657  
813-0109  
823-4600  
823-7935  
823-4617  
108-2580  
108-2303  
106-3767  
810-0784  
826-1053  
823-7849  
Wheel, 6” x 2”  
Washer, flat, ½”  
Screw, ¼ x 20 x ½”  
Handle, SDU 90, 100  
Handle, SDU 50, BKSDU  
Spring-loaded plunger  
Check valve, ¾” NPT (Added August 2010)  
Bushing, hex 1 x 3/4  
Pump handle  
Nipple, ¾ NPT close  
Discharge pipe, SDU 50, SDU 90  
Discharge pipe, SDU 100  
Discharge pipe, BKSDU  
SDU 100 Complete discharge assembly: pump, discharge pipes, check valve  
SDU 50/90 Complete discharge assembly: pump, discharge pipes, check valve  
BKSDU Complete discharge assembly: pump, discharge pipes  
Pump  
Kit, Pump Repair (includes two vanes, one spring, one rod, one gasket.)  
Suction pipe, SDU 50, 90, 100  
See BKSDU Pump Enclosure on page 11  
Suction pipe, BKSDU  
*
13  
14  
*
823-4581  
816-0132  
809-1001  
809-0047  
809-0193  
809-0119  
823-2422  
823-7804  
823-1683  
816-0877  
816-0264  
816-0134  
816-0133  
108-2210  
108-0706  
108-0705  
810-0742  
823-2420  
823-7803  
823-4580  
823-6268  
823-6267  
O-ring  
Screw, 1/4x20x1/2  
Cap, nut 1/4x20  
Flat washer, ¼ nylon  
Screw, 10x32x1/2  
Cover assembly, SDU 90  
Cover assembly, SDU 100  
Cover assembly, SDU 50, BKSDU  
Cover gasket, SDU 100  
Cover gasket, SDU 90  
Cover gasket, SDU 50, BKSDU  
Cover hinge gasket  
Crumb screen, SDU 100  
Crumb screen, SDU 90  
Crumb screen, SDU 50, BKSDU  
Latch  
Tank assembly, SDU 90  
Tank assembly, SDU 100  
Tank assembly, SDU 50  
*
15  
16  
*
*
*
*
*
*
*
*
*
17  
18  
*
*
*
*
Tank assembly, BKSDU  
Heater assembly for BKSDU (other BKSDU heater components on page 10,11)  
* Not illustrated.  
** CAUTION: Risk of fire and electric shock. Replace only with manufacturer’s cord set, part No. 8071224 for 120V.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
3
2
5
NOTE: See Page 6 for BKSDU  
pump assembly components.  
6
4
7
SDU 50, 90, 100  
and BKSDU units  
built before April  
2010.  
8
9
11  
10  
12  
13  
14  
(Crumb Basket  
optional)  
17  
16  
20  
15  
21  
22  
23  
24  
25  
19  
26  
27  
28  
30  
31  
29  
32  
11  
16  
33  
18  
34  
35  
36  
37  
38  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
1
Part #  
Component  
Pipe Assembly, Discharge  
823-4600  
823-4598  
813-0115  
813-0031  
810-1845  
813-0109  
810-0784  
826-2774  
826-1053  
816-0401  
813-0032  
823-4581  
810-0777  
Standard (includes Item 2) (use 823-4617 for BKSDU)  
For use with Item 4 (Hose Discharge) (includes Item 3)  
Nipple, ¾-inch x 3-inch Toe  
Bushing, ¾-inch x ½-inch  
Hose, 24-inch Discharge (Optional) (use 810-2797 for 48-inch hose)  
Nipple, ¾-inch x Close  
Pump (includes handle 810-0657, which may be ordered separately)  
Check valve kit  
Kit, Pump Repair (includes two vanes, one spring, one rod, one gasket.)  
Seal, Pump Shaft  
Bushing 1-inch x ¾-inch Hex  
Pipe Assembly, Suction  
2
3
4
5
6
*
*
*
7
8
9
10  
Pin, Plunger  
Handle Assembly  
823-2038  
823-2421  
809-0119  
SDU50 and BKSDU  
SDU90  
Screw, 10-32 x ½-inch Slotted Head  
Cover and Hinge Assembly  
11  
12  
823-1683SP SDU50 and BKSDU (does not include gasket (Item 13))  
823-2422SP SDU90 (does not include gasket (Item 13))  
Gasket, Cover (attach with 3M 1300L adhesive or equivalent)  
13  
816-0134  
816-0264  
816-0133  
SDU50 and BKSDU  
SDU90  
Gasket, Cover Hinge  
Crumb Basket (optional)  
SDU50 and BKSDU  
14  
15  
824-0438  
824-0615  
826-1376  
816-0132  
809-0200  
809-0193  
809-0191  
809-0047  
810-0742  
809-0359  
809-1001  
802-0227  
SDU90  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
Nut, 10-32 Keps Hex (Pkg. of 10)  
O-ring, Suction Pipe Assembly (2 required)  
Washer, Wheel ½” SAE  
Washer, ¼-inch Nylon Flat  
Lock Washer, ¼-inch  
Nut, ¼-20 S/S Cap  
Latch, Tank Cover  
Screw, #8 x ¼-inch  
Screw, ¼-20 x ½” Slotted Head  
Label, Fill Line  
Tank and Axle Assembly  
823-4580SP SDU50 and BKSDU  
826-2103  
823-4583  
823-1911  
807-1219  
809-0266  
810-0783  
809-0054  
814-0051  
809-0122  
810-1112  
807-1577  
807-1224  
823-1915  
809-0104  
809-0247  
815-0661  
SDU50 Retrofit Kit for SDU’s manufactured before Jan. 2004.  
SDU90 If replacing tank manufactured pre-Jan.2004, 823-4581 will also be needed.  
Housing, 120VAC Receptacle (BKSDU only) (use 823-5060 for 240VAC)  
Receptacle, 120V 3-wire (BKSDU only) (use 807-4108 for 240VAC)  
Screw, #10 x ½-inch Phillips Truss Head (use 809-0396 for 240VAC Receptacle)  
Cotter Pin, Wheel  
Nut, 10-32 Elastic Lock (BKSDU only)  
Bumper, Rubber (BKSDU only)  
Screw, 10-32 x -inch Slotted Round Head (BKSDU only)  
Wheel, 7-inch x 1½-inch  
Heater, 120V 50W 5” x 10” (BKSDU only)  
27x  
28x  
29  
30  
31  
32  
33  
34  
35  
*
Cord, Power – 120VAC (BKSDU only)** (use 106-4697 for 240VAC)  
Shield Heater (BKSDU only)  
Screw, 8-32 x ½-inch Slotted Truss Head (BKSDU only)  
Nut, 8-32 Keps Hex (BKSDU only)  
36  
37  
38  
*
Adhesive, 3M 1300L  
* Not illustrated.  
** CAUTION: Risk of fire and electric shock. Replace only with manufacturer’s cord set, part No. 8071224 for 120V.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
4
6
1
N O T E : T h e B K S D U p u m p  
assembly is identical to the SDU  
50/SDU 90 pump assembly except  
for the addition of the pump cover  
and insulation and the modified  
discharge pipe assembly.  
2
6
3
ITEM  
PART #  
823-1847  
900-4429  
811-0861  
823-4617  
809-0477  
809-0266  
COMPONENT  
Cover and Handle Assembly, BKSDU  
Box, BKSDU Pump  
Insulation, 3-inch X 50-foot Adhesive-Backed Foam  
Pipe Assembly, BKSDU Discharge  
Screw, #10 X ¼-inch Philips Truss Head  
Screw, #10 X ½-inch Philips Truss Head  
1
2
3
4
5
6
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 71106  
TEL 1-318-865-1711  
FAX (Parts) 1-318-688-2200  
FAX (Tech Support) 1-318-219-7135  
819-5703  
March 2011  
SERVICE HOTLINE  
1-800-551-8633  
PRINTED IN THE UNITED STATES  
Download from Www.Somanuals.com. All Manuals Search And Download.  

ELANsat Tech Network Card EM78P156N User Manual
ETI Sound Systems INC Speaker LX 18EV2 User Manual
Fellowes Chipper SB 95C User Manual
FieldServer Computer Drive FS 8700 101 User Manual
Fluke Power Supply Ti40 User Manual
Frigidaire Kitchen Grill Grill with Electronic Ignition User Manual
GE Oven JCKP30 User Manual
GE Power Screwdriver EPM 6000 User Manual
Goodman Mfg Furnace GMV95 GCV9 User Manual
G Technology Server 0G1871 User Manual