INSTALLATION INSTRUCTIONS
TM
DishDrawer dishwasher
DD60S 7 & DD60ST 7 models
NZ AU GB IE
590200C
12.11
Download from Www.Somanuals.com. All Manuals Search And Download.
3
2a
SAFETY AND WARNINGS - ALL MODELS
IMPORTANT SAFETY INSTRUCTIONS!
Installation of this dishwasher requires basic mechanical and electrical skills.
Be sure to leave these Instructions with the Customer.
WARNING!
Electrical shock hazard
Installation must comply with your local building and electricity regulations.
At the completion of the dishwasher installation, the Installer must perform the Final Checklist.
Remove all packaging materials supplied with the dishwasher.
Before installing the dishwasher, remove the house fuse or open the circuit
breaker.
This appliance must be earthed. In the event of a malfunction or breakdown,
earthing will reduce the risk of electric shock by providing a path of least
resistance for electric current. This appliance is equipped with a cord having an
equipment-earthing conductor and an earthing plug. The plug must be plugged
into an appropriate outlet that is installed and earthed in accordance with all
local codes and ordinances. WARNING- Improper connection of the equipment-
earthing conductor can result in a risk of electric shock. Check with a qualified
electrician or service representative if you are in doubt as to whether the
appliance is properly earthed.
This dishwasher is manufactured for indoor use only.
Ensure all water connections are turned OFF. It is the responsibility of the plumber and
electrician to ensure that each installation complies with all Codes and Regulations.
The dishwasher MUST be installed to allow for future removal from the enclosure if service is required.
The switched power outlet must be outside the dishwasher cavity, so that it is accessible after
installation.
Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to
the power supply cord and hoses.
If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid
damage from water spillage.
Do not modify the power supply plug provided with the appliance - if it will not
fit the outlet, have a proper outlet installed by a qualified electrician. Do not use
an extension cord, adapter plug or multiple outlet box.
Failure to follow this advice may result in electrical shock or death.
Make sure only new hoses are used for connection (supplied with the dishwasher). Old hoses should
not be reused.
Failure to install the dishwasher correctly could invalidate any warranty or liability claims.
If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle,
boat or mobile facility containing the product to the service shop at your expense or pay the service
technician’s travel to the location of the product.
WARNING!
Cut hazard
Take care - panel edges are sharp.
Failure to use caution could result in injury or cuts.
SAVE THESE INSTRUCTIONS
2b
ADDITIONAL SAFETY AND WARNINGS - INTEGRATED MODELS ONLY
WARNING!
IMPORTANT SAFETY INSTRUCTIONS!
Read these instructions completely and carefully.
Ensure the product is not plugged in.
Fitting integrated front panels requires access to electrical service areas.
This work must be performed and certified by a qualified electrical service technician.
Installation of custom panels requires basic mechanical and electrical skills.
Installation must comply with your local building and electricity regulations.
Failure to install the custom panels correctly could invalidate any warranty or liability claims.
Electrical Shock Hazard
WARNING: To reduce the risk of electrical shock, fire, or injury to persons, the
installer must ensure that the dishwasher is completely enclosed at the time of
installation.
SAVE THESE INSTRUCTIONS
Before fitting the front panels and connecting the integrated badges (where
present), the installer must ensure that the dishwasher is disconnected from the
power supply.
After installing the front panel, the installer must ensure that the following
components are electrically earthed: the panel bracket, the integrated badge
(where present) and any custom metal component (e.g. handle) that extends
past the rubber seal.
Failure to follow these warnings may result in electrical shock, injury or fire.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
3a
PARTS SUPPLIED - ALL MODELS
Side mounting
bracket kit
Clamp (1)
Drain hose
support (1)
Drain hose
joiner (1)
Wire clip (1)
Phillips
38 mm
Rubber
Moisture
protection
tape (1)
16 mm
bottom
washer for
(for securing
(for securing
(A and B) (2)
screws (7)
fixing screws
& metal
inlet hose (1)
Drain hose joiner)
Drain hose joiner)
(to prevent
OPTIONAL
(comes already
washers (2)
moisture damage)
fitted)
Cavity bracket kit (1)
supplied with Tall height
Designer and Integrated
models only
If the Drain hose supplied is not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose by 3.6m.
The kit is available from the nearest Fisher & Paykel Authorised Service Centre or through our local website listed at the end of this document.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
3b
ADDITIONAL PARTS SUPPLIED WITH INTEGRATED MODELS
External Venting kit (1)
Panel bracket (1)
(attached to
product)
Panel mounting
screws (6)
Integrated rectangular badge (1)
(Satin chrome supplied)
supplied with Integrated
models with remote (NZ AU)
only
supplied with Integrated models
with badge (GB IE) only
Download from Www.Somanuals.com. All Manuals Search And Download.
6
4
PRODUCT DIMENSIONS
K
H
Plan
D
C
A
I
Side
G
F
J
B
E
Product dimensions (mm)
STANDARD HEIGHT MODELS
TALL HEIGHT MODELS
overall height1 of product (incl. front panel height)
overall width of product
410
599
582
553
556
29
410
599
571
553
545
18
410
410
599
5713
454
599
582
553
556
29
4782
454
599
5713
454
4782
599
5713
4782
599
5713
A
B
C
D
E
F
G
H
I
599
5713
553
5453
16-20
410
599
571
553
545
18
599
5713
overall depth of product (excl. handle)
depth of chassis (to back of front panel)
maximum extension of drawer (excl. handle)
depth of front panel (excl. handle)
height1 of chassis
553
5453
553
553
5453
553
553
5453
5453
16-20
454
5453
16-20
454
16-20
410
16-20
454
16-20
454
410
n/a
394
7
410
41
454
n/a
438
7
454
41
depth of handle
n/a
n/a
n/a
n/a
n/a
n/a
height of front panel
398
8
4084
min. 2
n/a
min. 398
min. 8
n/a
470
8
4525
min. 2
n/a
min. 442
min. 8
n/a
4765
min. 2
n/a
min. 470
min. 8
n/a
height of ventilation gap below front panel
height from top of handle to top of front panel
J
K
n/a
64
n/a
64
1includes 2mm high bracket slots 2Includes cavity bracket 3Assuming front panel thickness of 18 mm
4Recommended for a 2 mm ventilation gap below panel, if cavity height is 412 mm 5Recommended for a 2 mm ventilation gap below panel
Download from Www.Somanuals.com. All Manuals Search And Download.
7
5
CABINETRY DIMENSIONS
M
Plan
N
L
Side
Cabinetry dimensions (mm)
STANDARD HEIGHT MODELS
TALL HEIGHT MODELS
inside height of cavity
inside width of cavity
inside depth of cavity
min. 412
600
min. 412
600
min. 412
600
min. 412
600
456
600
480
456
600
456
480
600
480
600
L
M
N
600
600
min. 560
min. 560
min. 560
min. 560
min. 560
min. 560
min. 560
min. 560
min. 560
min. 560
Minimum clearances from adjacent cabinetry
min. 13 mm
clearance
from a corner
min. 2 mm
clearance
to adjacent
cupboard door
Cavity height options allow you to match dishwasher with your cabinetry or companion products
Tall height Classic models
Standard height models
Tall height Designer models
L
L
L
Compact
Oven
dishwasher
dishwasher
dishwasher
Single
Oven
min.
456mm
480mm
412mm
Tall height Integrated models
You may choose to install Tall height Integrated
models into either a 456 mm or a 480 mm high cavity.
Note: the minimum height of the custom drawer front
panel will also be different for these two options.
Download from Www.Somanuals.com. All Manuals Search And Download.
8
6a
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - CUSTOM FRONT PANEL CALCULATIONS
min. 2 mm
FRONT PANEL SPECIFICATIONS
16 -20 mm panel thickness
Adequately sealed to withstand moisture (50OC @ 80% RH)
Maximum weight of panel: 9 kg
The following calculations assume the top of the panel is aligned
with the top of the adjacent cabinetry:
A
min. 2 mm
min. 2 mm
WIDTH OF THE PANEL
Measure A (the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
WIDTH OF PANEL
min. 2 mm
clearance to
WIDTH OF PANEL
(min. 596 mm)
adjacent cabinet
front (min. 2 mm)
A
B
HEIGHT
OF PANEL
-
2
x
=
HEIGHT OF THE PANEL
Measure and write it in the first box below, then complete
min. 2 mm ventilation gap
with external venting kit
installed
B
the equation.
ventilation gap
(min. 2 mm)
HEIGHT OF PANEL
B
-
=
min. 2 mm ventilation gap with
external venting kit installed
Note: when the top of the dishwasher has to be lower than the adjacent cabinetry,
the panel can be increased in height.
Download from Www.Somanuals.com. All Manuals Search And Download.
9
6b
INTEGRATED MODELS WITH BADGE (GB IE) ONLY - CUSTOM FRONT PANEL CALCULATIONS
min. 2 mm
FRONT PANEL SPECIFICATIONS
16 -20 mm panel thickness
Adequately sealed to withstand moisture (50OC @ 80% RH)
Maximum weight of panel: 9 kg
The following calculations assume the top of the panel is aligned
with the top of the adjacent cabinetry:
A
min. 2 mm
min. 2 mm
WIDTH OF THE PANEL
Measure A (the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
WIDTH OF PANEL
min. 2 mm
clearance to
WIDTH OF PANEL
(min. 596 mm)
adjacent cabinet
front (min. 2 mm)
A
B
HEIGHT
OF PANEL
-
2
x
=
HEIGHT OF THE PANEL
Measure and write it in the first box below, then complete
min. 8 mm ventilation gap
B
the equation.
ventilation gap
(min.8 mm)
HEIGHT OF PANEL
B
-
=
Note: when the top of the dishwasher has to be lower than the adjacent cabinetry,
the panel can be increased in height.
min. 8 mm ventilation gap
Download from Www.Somanuals.com. All Manuals Search And Download.
10
7a
CAVITY PREPARATION
Important!
BENCHTOP
The power outlet must be
located in a cabinet adjacent
to the dishwasher cavity.
Moisture
220-240 VAC min. 4.8 A
10 mm
protection
tape must
be applied.
Water Connection
Recommended COLD
(Maximum 60°C).
These marks indicate
formed bracket screw
locations, if securing
by drawer removal.
¾ “ BSP (GB20) to
suit flat washer.
Water Pressure
Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)
min.
ø
60 mm
Services can be
located either side
of the dishwasher.
Important!
Models without water
softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)
Adjacent cabinetry
must not extend
above cavity base
Download from Www.Somanuals.com. All Manuals Search And Download.
11
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH SAME CABINET
7b
Services can be located
either side of dishwasher
External Venting kit (1)
max. 5 mm
Shelf cutouts
VENT HOSE
ø
60 mm
SERVICES
220 mm
100 mm
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - PREPARATION FOR EXTERNAL VENTING THROUGH ADJACENT CABINET
7c
The ø60 mm services hole should
be enlarged to accomodate the
extra venting hose by
ø60mm
cutting out some material from
the bottom corner.
External Venting kit (1)
Services can be located
either side of dishwasher
Shelf cutouts
max. 5 mm
VENT HOSE
& SERVICES
ø
60 mm
220 mm
100 mm
Download from Www.Somanuals.com. All Manuals Search And Download.
12
8
MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE
Left hand side
Right hand side
Drain hose - 2000 mm
Drain hose - 2000 mm
Drain hose - 1800 mm
Inlet hose - 1650 mm
nlet hose - 1650 mm
Inlet hose - 1250 mm
Inlet hose - 1250 mm
P
P
o
o
w
w
e
e
r
r
c
c
o
o
r
r
d
d
(
(
e
e
x
x
c
c
l
l
.
.
p
p
l
l
u
u
g
g
)
)
-
-
1
1
6
6
5
5
0
0
m
m
m
m
P
P
o
o
w
w
e
e
r
r
c
co
o
r
r
d
d
(
(
e
e
x
xccll.. p
p
l
lug)
)
-
-
1
1
6
6
5
5
0
0
m
mm
V
V
e
e
n
n
t
t
i
i
n
n
g
h
h
o
o
s
s
e
e
-
-
1
1
5
5
2
2
5
5
m
m
m
m
V
V
e
e
n
n
t
t
i
i
n
n
g
g
h
ho
o
s
s
e
e
-
-
1
1
9
9
2
2
5
5
mm
mm
(Integrated models with
remote (NZ AU) only)
(Integrated models with
(ntgrted irles modls onl)
remote (NZ AU) only)
Download from Www.Somanuals.com. All Manuals Search And Download.
13
9
TALL HEIGHT DESIGNER & INTEGRATED MODELS FOR 480 mm CAVITY ONLY - ATTACH CAVITY BRACKET
The enclosed cavity bracket is fitted before installation in order to conceal the gap at the top of the cavity left after installation.
Firmly push the bracket so that
the prongs engage with the top
tabs and it clicks into place.
Important!
1
2
Ensure the prongs have not been
driven down into the chassis as
this will damage the lid below.
1
Ensure the top trim seal
is facing forward after
attaching the bracket.
2
Ensure the cavity panel
bracket is positioned so
that the “F”arrow is
pointing towards the front
of the chassis.
Download from Www.Somanuals.com. All Manuals Search And Download.
14
NOW CHOOSE WHICH INSTALLATION METHOD (a) or (b)
IS MORE SUITABLE FOR YOUR CABINETRY...
RECOMMENDED METHOD (a) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)
10a
11a
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY -
ATTACH VENTING HOSE
ATTACH SIDE MOUNTING BRACKETS
Clip all four side mounting
A
brackets into their slots
B
using a flat-bladed
Check that the fitted elbow is rotated
left or right (depending on the direction
of the routing), then ensure the venting
hose is securely attached to it.
screwdriver. Ensure they’re
securely fitted before
sliding product into cavity.
B
A
B
A
Fitted Elbow
A
B
The mounting slots are in pairs,
one on each side diagonally
across the product. A bracket
must match A slot and B
bracket must match B slot.
Download from Www.Somanuals.com. All Manuals Search And Download.
15
12a
13a
PULL THROUGH HOSES & MOVE INTO THE CAVITY
SECURE THE DRAWER
1
Open the
drawer halfway.
Using a flat-bladed
screwdriver, prise
Vent Hose
the grey
(Integrated models
with remote (NZAU)
only)
Replace the grey
rubber plug out
of the trim moulding.
rubber plug back into
the trim moulding
and ensure the trim
seal is facing forward.
2
3
Using a small Philips
screwdriver,
screw through the trim
moulding, securing the
side mounting bracket
to the cabinetry.
vent either
through
same cabinet
or adjacent
Do not damage the
rubber trimseal.
cabinet as per
As you push product in, pull through hoses and
step 7b or 7c
cord, ensuring they don’t get kinked or twisted.
Repeat for all
four brackets.
Important!
If product cannot be pushed in far enough, pull
out again and rearrange hoses and cord. Do not
use excessive force, as doing so may squash the
hoses and lead to incorrect operation.
14a
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - SECURE THE EXTERNAL VENT
2
1
After routing the vent hose
through and out the hole
cutout, attach and secure the
vent by tightening the four
screws provided.
Air
flo
w
Download from Www.Somanuals.com. All Manuals Search And Download.
16
ALTERNATIVE METHOD (b) - SECURE BY DRAWER REMOVAL
10b
11b
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY -
ATTACH VENTING HOSE
PULL THROUGH HOSES & MOVE INTO THE CAVITY
Check that the fitted elbow is
rotated left or right (depending
on the direction of the routing),
then ensure the venting hose is
securely attached to it.
Vent Hose
(Integrated models
with remote (NZAU)
only)
Fitted Elbow
vent either
through
same cabinet
or adjacent
cabinet as per
As you push product in, pull through hoses and
cord, ensuring they don’t get kinked or twisted.
Important!
step 7b or 7c
If product cannot be pushed in far enough, pull
out again and rearrange hoses and cord. Do not
use excessive force, as doing so may squash the
hoses and lead to incorrect operation.
Download from Www.Somanuals.com. All Manuals Search And Download.
17
12b
13b
REMOVE THE DRAWER
SECURE THE DRAWER TO THE CABINETRY
4
1
The product has three
pairs of fixing points:
Product may
move. Mark
chassis position
on cavity
Ensure the sound insulation is
repositioned correctly.
To prevent kinked hoses, we recommend
rotating the drawer anti-clockwise and
resting it on its side after removal.
2
5
2
a pair of fixing
3
two pairs of formed
100 mm
holes either side on
the bottom
brackets on either
side of the chassis
(use 16 mm screws)
Press the release tabs
in on either side and
push back to release
drawer from runners
(use 38 mm fixing
screws & washers)
1
Push drawer runners back in.
14b
15b
REFIT THE DRAWER ONTO THE RUNNERS
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY -
SECURE THE EXTERNAL VENT
Ensure the drawer
3
is now rotated
elease tabs
mm
clockwise back.
d the r
ar
w
r
o
ull f
P
on both sides 100
4
Before refitting the drawer,
ensure the hoses are not
twisted and the latches at
the rear of each drawer
runner are facing forward.
5
2
1
After routing the vent hose
through and out the hole
cutout, attach and secure the
1
vent by tightening the four
Air
flo
w
screws provided.
2
Ensure the release tabs on
both sides are reset fully.
Download from Www.Somanuals.com. All Manuals Search And Download.
18
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - INSTALLING THE FRONT PANEL
ATTACH PANEL TO PANEL BRACKET
16a
17a
REMOVE BRACKET FROM PRODUCT
WARNING!
Electrical Shock Hazard
There must be at least
Before continuing, ensure that the product is
disconnected from the power supply.
3 screws used each side
2
Failure to follow this warning may result in
electrical shock, injury or fire.
16 mm x6
1
1
2
Align bottom of panel
with bottom of bracket
1
3
18a
19a
EARTH THE PANEL
ATTACH PANEL TO PRODUCT
Important!
Ensure the rubber seal
between the drawer
and panel is kept in
place.
2
WARNING!
1
2
WARNING!
Electrical Shock Hazard
To earth the panel bracket, connect the earth
wire from the product to one of the tabs.
Any custom metal component (e.g. handle)
that extends past the rubber seal must be
earthed too.
Failure to follow these warnings may result
in electrical shock, injury or fire.
When refitting the
door pins,
ensure they are
orientated as shown.
Repeat for the other drawer
Download from Www.Somanuals.com. All Manuals Search And Download.
19
INTEGRATED MODELS WITH REMOTE (NZ AU) ONLY - INSTALLING THE FRONT PANEL
ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS
20a
With the front panel fitted, insert an appropriately
sized Philips screwdriver into the hole above the
door pin and rotate the panel up or down to align
the gaps in your cabinetry.
Repeat on the other side if necessary.
+ or - 2 mm
The panel has a maximum travel of 2 mm up or
down.
Important!
Ensure that you maintain a minimum of 2 mm ventilation
gap below the panel.
Download from Www.Somanuals.com. All Manuals Search And Download.
20
INTEGRATED MODELS WITH BADGE (GB IE) ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS
16b
17b
DETERMINE BADGE CUTOUT LOCATION
REMOVE BRACKET & DISCONNECT BADGE
WARNING!
Electrical Shock Hazard
Before continuing, ensure that the product is
disconnected from the power supply.
3
Failure to follow this warning may result in
electrical shock, injury or fire.
1
127 mm
Badge z
o
ne
255 mm
2
1
30 mm
25 mm
4
18b
19b
ROUTE BADGE WIRING THROUGH PANEL
ATTACH PANEL TO PANEL BRACKET
There must be at least
3 screws used each side
2
16 mm x6
1
1
Align bottom of panel
with bottom of bracket
2
Download from Www.Somanuals.com. All Manuals Search And Download.
21
INTEGRATED MODELS WITH BADGE (GB IE) ONLY - INSTALLING THE FRONT PANEL & BADGE CONTROLS
20b
21b
REATTACH BADGE & EARTH THE PANEL
ATTACH PANEL TO PRODUCT
Important!
Ensure the rubber seal
between the drawer
and panels is kept in
place.
WARNING!
Electrical Shock Hazard
Connect the integrated badge
earth wire to one of the two tabs
provided on the panel bracket.
To earth the panel bracket,
connect the earth wire from the
product to the other tab.
2
Any custom metal component
(e.g. handle) that extends past the
rubber seal must be earthed too.
Failure to follow these warnings
may result in electrical shock,
injury or fire.
2
1
2
Push the panel in
then up to locate.
When refitting the
door pins, ensure
they are
1
orientated as shown.
22b
ADJUST PANEL HEIGHT TO ALIGN THE CABINETRY GAPS
With the front panel fitted, insert an appropriately
sized Philips screwdriver into the hole above the
door pin and rotate the panel up or down to align
the gaps in your cabinetry.
Repeat on the other side if necessary.
The panel has a maximum travel of 2 mm up or
down.
+ or - 2 mm
Important!
Ensure that you maintain a minimum of 8 mm ventilation
gap below the panel.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
23
THERE ARE TWO DIFFERENT PLUMBING AND DRAINAGE OPTIONS. CHOOSE WHICH IS MORE SUITABLE.
Dishwasher using sink trap with drain hose joiner
Dishwasher and Standpipe Ø 38 mm
If space is limited
for fixing, push
If space is limited
for fixing, push
Supplied drain hose joiner
hose through drain
hose through drain
hose support
19 mm waste tee
hose support
to required height
to required height
max.
120
mm
3
38 mm
2
2
1
1
Important!
Do not connect the
drain hose to a waste
disposal unit, as this
type of connection may
lead to a blockage in
the drain hose.
see 24
see 24
min. R 200 mm
min. R 200 mm
Ensure drain hose is routed straight
to joiner. Remove excess drain hose
material if necessary.
Do not shorten the inlet hose.
24
25
PLUG PRODUCT IN
CONNECT INLET HOSE TO COLD WATER
Tighten coupling with spanner.
Ensure the
supplied
rubber
washer is
180o
No leaks!
fitted inside
the coupling.
5
1
2
Download from Www.Somanuals.com. All Manuals Search And Download.
23
27
26 FINAL CHECKLIST
TROUBLESHOOTING
Excessive water remaining above the filter plate, after the rinse cycle
Check for a kinked drain hose, blocked waste connection, highloop not
properly installed, drain hose not routed correctly or spray arm not in place.
No water supply (This is displayed as a ‘U1’ fault -- see section ‘If there is a
fault’ in the User guide for how to recognise this fault on models without a
display.)
Check all parts are installed.
Ensure that all panels and parts thereof are secure and final electrical tests have
been conducted in accordance with local electrical regulations.
Ensure product is level, securely fastened to the cabinetry and opens and
closes freely. The drawer must be free to fully close with no resistance from the
cabinetry.
Check water is connected and turned on.
Ensure inlet hose to water supply has supplied rubber washer fitted, and that
it’s tightened a further half turn after seal contact.
The dishwasher is beeping continuously
There is a fault. See section ‘If there is a fault’ in the User guide for further
information and instructions.
No program indicator lights up when the drawer is opened
Ensure power is connected and is switched on. If it is and still no indicator
ligths up, see the ‘Preference options’ section of the ‘Quick start guide’. An
option called ‘Open drawer auto power-on’ may need to be turned on.
Water around water supply and drainage connections
Check connections, existing plumbing and hoses for leaks. Check rubber
washer and hose clamp are correctly fitted.
Ensure any knockouts or plugs in drain connection have been drilled out and
drain connection has been made.
The drain hose joiner must not support the weight of excess hose material.
Keep drain hose as fully extended as possible to prevent sagging. Any excess
length of drain hose should be kept on the dishwasher side of the highloop.
If connecting the drain hose to the sink trap, ensure the Highloop is a minimum
150 mm higher than the drain hose joiner.
If product is tipping
Ensure the product is secured to the cabinetry.
If front panels are misaligned
Check and relevel product. Check the cabinetry is square. For Integrated
models, check and adjust front panel alignment if necessary.
Drawer doesn’t close properly
Ensure any packaging or tape securing the racks is removed from the drawer.
Turn on the power and water supplies, then open the drawer. You should hear a
beep and see a program indicator light up on the internal control panel.
Check the spray arm is in place and free to rotate.
Ensure nothing is obstructing the drawer from closing properly eg sound
insulation, hoses or drawer latches.
Spray arm
If a problem occurs, consult the ‘Troubleshooting’ section of the User guide.
If after checking these points you still need assistance, please refer to the
Service & Warranty book for warranty details and your nearest Authorised
Service Centre, or contact us through our website, listed below.
Add three cups of water into the drawer. Press
on the internal control panel
until the indicator of the ‘Rinse’ program lights up. Close the drawer and press
to start the program.
Important!
SAVE THESE INSTRUCTIONS
After the Rinse program has finished, ensure the dishwasher has run and
drained correctly.
The models shown in this document may not be available in all markets and are subject to change
at any time. For current details about model and specification availability in your country, please
visit our local website listed at the end of this document or contact your local Fisher & Paykel
dealer.
Check water supply and drainage connection for leakage.
Download from Www.Somanuals.com. All Manuals Search And Download.
|