FS-B-OPC-01 Start-up Guide
APPLICABILITY & EFFECTIVITY
Description
FS-B-OPC Series
FieldServer
The instructions are effective for the above as of February 2009
Kernel Version:
Document Revision:
5.12
5
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 3 of 10
1
PRE-INSTALLATION CHECK LIST
1.1 Supplied equipment
FS-B-OPC-01 Series FieldServer
loaded with Modbus RTU driver, SMT Ethernet driver, FST OPC Server Configurator and any other drivers
ordered.1
USB Flash Drive loaded with:
FS-B-OPC-01 Series Start-up Guide
FieldServer Configuration Manual
FieldServer Utilities Manual
Driver Manual(s) specific to all Drivers ordered with the FieldServer.
Support Utilities (for the following platforms only:
Windows XP
Windows 2000
Windows NT
Windows 98
Any additional folders related to special files configured for a specific FieldServer.
Additional components as required -. See Driver Manual Supplement for details
Accessories:
6 ft Serial RS-232 connection pigtail (Part Number FS-8917-10)
7-ft Cat5 cable with RJ45 connectors at both ends (Part Number FS-8915-10)
Power Supply
1.2 Mounting
The FS-B-OPC-01 Series FieldServer is supplied with an accessory bag which allows selection of adhesive feet (for
standing on a shelf).
1.3 Wiring
Select an external power supply certified for safety, for the correct destination country and an output rating,
which is considered a NEC Class 2 circuit or is a SELV Limited power source with the following ratings:
12-14 VDC, 5.0-4.28A;
The operating environment for the product is 0 to 60°C (32 to 140°F).
1 Note that a default configuration file has already been loaded onto the FieldServer. Check the Driver Manual and the FieldServer
Configuration Manual for further information on this file.
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 5 of 10
2.2 Specifications
Power requirements (power supply is external)
FS-B-OPC-01 power supply P/N PWR-ACDC-12v-5A-60W
Input voltage: 100-240Vac, 60W (max);
Output voltage / current: 12Vdc @ 5.0A
Physical Dimensions(excluding the external power supply)
(WxDxH):
Weight:
7.70 x 9.50 x 2.10 inches (19.56 x 24.13 x 5.33 cm)
2.4 lbs. (1.09 Kg)
Available Ports
1 x DB9 RS-232 serial port
1 x RJ45 10-BaseT Ethernet connector
Environment:
Operating Temperature: 0 – 60°C (32 – 140°F)
Humidity:
10 - 90% RH (non-condensing)
(Specifications subject to change without notice)
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 6 of 10
3
CONNECTION TO THE DEVICE
The 12VDC power supply received with the unit needs to be plugged into a power source and then connected to
the back of the FieldServer. Ensure that the power supply used complies with the specifications provided in
Section 2.2.
Power
Serial
Ethernet
Figure 3-1: View of back of FS-B-OPC-01 showing Connection Ports
3.1 RS-232 connection
The FS-B-OPC-01 Series FieldServer is shipped with the RS-232 port activated.
Connect the FS-8917-10 cable (supplied) between the RS-232 port on the OPC FieldServer and the device as shown
in the connection diagram. Note that the cable labels refer to the Tx and Rx signals on the FS-B-OPC and must be
connected to the opposite signal on the remote device.
Remote RS-232 Device
3.1.1 Connector Pinouts
Tx Rx GND
FS-OPC
Remote Device
Wire Color
Signal Pin # Signal Pin #
Tx
Green
Red
Black
Tx
Rx
GND
3
2
5
Rx
Tx
GND
8
1
4
Labels refer to
signal reference
on FS-B-OPC
G
x
N
R
D
FS-8917-10
FS-8917-10
DB9M on FS-B-OPC
Figure 3-2: FS-B-OPC Serial RS-232 Connection
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 7 of 10
3.2 Ethernet Connection
If connecting to a hub/switch use the provided Cat5 UTP Ethernet cable to connect the FieldServer to the hub. If
connecting directly to the device, an Ethernet Crossover cable is required (not provided).
Note that the front USB ports and Compact Flash port are not activated.
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 8 of 10
4
OPERATION
Read this Start-up Guide in conjunction with the Configuration Manual, the Driver Manual(s) and the Utilities
manual.
4.1 Connect and Power the FieldServer.
Connect the power adapter to a 100 to 240vAC power supply. Ensure that the power supply used complies
with the specifications provided in Section 2.2
Power button
Figure 4-1: View of front of FS-B-OPC-01 Showing Power LED and power button
Press the Power Button on the front of the FS-B-OPC-01.
Wait approximately 3-5 minutes for unit to operate.
4.2 Connect all wiring to unit
Connect a standard CAT-5 Ethernet cable to the Ethernet port of the FS-B-OPC-01.
Make appropriate RS232 wiring connections to the RS-232 port of the FS-B-OPC-01. Refer to Section 3 for
more information.
4.3 Set the IP Address
If the FieldServer was not ordered with a Custom Configuration, the IP address is set to automatically update
from any local DHCP server.
If no IP address was ordered, then a standard PC monitor, Keyboard, and Mouse must be connected to the
FS-B-OPC-01 and the IP address set for a normal PC.
Once the IP address is found or assigned, the configuration of the FST OPC Server Configuration Utility must
be changed to match that IP address. Please reference the FS-8707-06 manual for more instruction.
4.4 Change the Configuration File to Meet the Application
The configuration of the FieldServer is provided to the FieldServer’s operating system via a comma-delimited
file
called
“CONFIG.CSV”
which
can
be
accessed
from
the
Start|Programs|FieldServerTechnologies|Configuration File folder.
If ordered with the FieldServer, the custom configuration is installed; (Reference documentation FS-8790-
XX).
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 9 of 10
If a custom configuration is not purchased, a template config.csv is loaded on the FieldServer to facilitate
user configuration of the FieldServer.
Refer to the Configuration Manual in conjunction with the Driver supplements for information on
configuring the FieldServer. Note: FieldServer Technologies offers training on this topic as well as a
configuration service to complete this portion of the work. See www.fieldserver.com for specific details.
4.5 Run the FieldServer PC Bridge Utility
If a Custom Configuration was ordered, this software will run automatically and this step can be skipped
Once the config.csv file is set-up, double click on the FieldServer PC Bridge icon on the desktop to run the
FieldServer software.
4.6 Configure the FST OPC Server Configurator to meet the Application
If a Custom Configuration was ordered this step can be skipped
If a Custom Configuration was not ordered, please follow the instructions supplied in the FS-8707-06 driver
manual to configure the OPC Server to connect to the correct Data Arrays.
The OPC Configurator is installed in c:\program files\FieldServer\FST., there is a shortcut on the desktop and
it can be found in the start menu under Start|Programs|FST OPC Server for FieldServers.
4.7 Test and commission the FieldServer
Connect the FieldServer to the third party device(s), and test the application.
It may be necessary to connect a standard PC monitor, PC Keyboard and PC Mouse to perform any
diagnostics or configuration
If necessary, refer to the Troubleshooting manual which can be found in the FieldServer utilities directory
under Documentation.
Before contacting FieldServer technical support, send your config.csv file, and the *.fst file from your FST
problem(s) occurring on the system.
Download from Www.Somanuals.com. All Manuals Search And Download.
FS-B-OPC-01 Series FieldServer Start-up Guide
Page 10 of 10
Appendix A. Limited Warranty
FieldServer Technologies warrants its products to be free from defects in workmanship or material under normal
use and service for two years after date of shipment. FieldServer Technologies will repair or replace without
charge any equipment found to be defective during the warranty period. Final determination of the nature and
responsibility for defective or damaged equipment will be made by FieldServer Technologies personnel.
All warranties hereunder are contingent upon proper use in the application for which the product was intended
and do not cover products which have been modified or repaired without FieldServer Technologies approval or
which have been subjected to accident, improper maintenance, installation or application, or on which original
identification marks have been removed or altered. This Limited Warranty also will not apply to interconnecting
cables or wires, consumables or to any damage resulting from battery leakage.
In all cases FieldServer Technology’s responsibility and liability under this warranty shall be limited to the cost of
the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this
warranty provision and compliance with such instruction shall be a condition of this warranty.
Except for the express warranty stated above, FieldServer Technologies disclaims all warranties with regard to the
products sold hereunder including all implied warranties of merchantability and fitness and the express warranties
stated herein are in lieu of all obligations or liabilities on the part of FieldServer Technologies for damages
including, but not limited to, consequential damages arising out of/or in connection with the use or performance
of the product.
Download from Www.Somanuals.com. All Manuals Search And Download.
|