Extron electronic Stereo System MHR 5STP 2 User Manual

Specifications — MHR-5STP-2 Cable  
UL NEC/  
C(UL) CEC  
UL AWM  
Temp.  
Standard  
Lengths Weights  
Shipping Conductor  
Nominal  
Core OD  
Shielding  
Materials  
(% coverage)  
Nom. DCR  
Nominal  
OD  
Nominal  
Capacitance  
Nominal  
Attenuation  
Description  
Nom.  
Vel.  
of  
No.  
of  
Cond.  
Nom.  
Imp.  
(ohms)  
(stranding)  
Diameter  
Nom. DCR  
Part No. (length)  
Model  
dB/  
dB/  
MHz  
Prop.  
Ft.  
m
Lbs. kg  
Inch mm  
Inch mm  
pF/ft pF/m  
100 ft 100 m  
Composite: (5) 26 AWG Miniature Coax • (2) 22 AWG Shielded Twisted Pairs • Coax Shielding: Aluminum Foil (100%) + Tinned Copper Serve  
Nonplenum Cable • Gas-injected Foamed Polyolefin Insulation • PVC Inner Jackets • Gray PVC Outer Jacket  
1
5
10  
20  
50  
-0.5  
-1.2  
-1.7  
-2.4  
-3.8  
-4.5  
-5.4  
-6.3  
-7.3  
-7.7  
-9.1  
-11.5  
-16.4  
-19.5  
-43.6  
-1.7  
-3.9  
-5.5  
26 AWG  
(7/34)  
0.019"  
Alum. Foil  
(100%)  
5
coax  
0.072 1.83  
75  
81%  
16.7  
54.8  
500 152.4 42 19.1  
304.8  
Single:  
22-175-02 (500')  
22-175-03 (1000')  
0.105 2.67  
red, green, blue,  
black, yellow  
1000  
83 37.6  
Tinned Cu  
Serve (95%)  
-7.8  
MHR-5STP-2  
0.48 mm,  
-12.3  
-14.8  
-17.6  
-20.6  
-23.9  
-25.4  
-29.9  
-37.3  
-53.8  
-64.0  
-143.0  
Tinned Cu  
12.2 ohms/  
1k ft,  
40.0 ohms/  
1 km  
71  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
41 ohms/  
1k ft,  
135 ohms  
1 km  
NEC CM  
UL 1581  
CSA FT-4  
Sweep tested 5 MHz to 1 GHz.  
66% 35 115  
22 AWG  
(7/30)  
0.030"  
Alum. Foil  
(100%)  
Single:  
2
shielded  
twisted  
pairs  
0.046 1.2  
red and black,  
green and white  
conductor-  
conductor  
60 °C  
17 ohms/  
1k ft,  
56 ohms/  
1 km  
0.76 mm,  
Tinned Cu  
62  
203  
Min. bend radius: 4.0"  
17 ohms/  
1k ft,  
56 ohms  
1 km  
conductor-  
conductor,  
connected to  
shield  
Overall:  
Overall  
cable  
0.400 10.2  
gray  
Plenum Cable • Gas-injected Foamed FEP Insulation • Fluorocopolymer Inner Jackets • Blue Fire-resistant PVC Outer Jacket  
38  
1
5
10  
20  
50  
-0.5  
-1.2  
-1.7  
-2.4  
-3.8  
-4.5  
-5.4  
-6.3  
-7.3  
-7.7  
-9.1  
-11.5  
-16.4  
-19.5  
-43.6  
-1.7  
-3.9  
-5.5  
152.4  
26 AWG  
(7/34)  
0.019"  
Alum. in  
Polyester Tape  
(100%)  
500  
17.2  
5
coax  
0.074 1.88  
75  
81%  
16.7  
54.8  
Single:  
22-181-02 (500')  
22-181-03 (1000')  
0.102 2.59  
red, green, blue,  
black, yellow  
1000 304.8 75 34.0  
-7.8  
MHR-5STP-2P  
0.48 mm,  
Tinned Cu  
Serve (95%)  
-12.3  
-14.8  
-17.6  
-20.6  
-23.9  
-25.4  
-29.9  
-37.3  
-53.8  
-64.0  
-143.0  
Tinned Cu  
71  
100  
135  
180  
200  
270  
400  
750  
1000  
3000  
41 ohms/  
1k ft,  
135 ohms  
1 km  
12.2 ohms/  
1k ft,  
40.0 ohms/  
1 km  
NEC CMP  
UL 910  
CSA FT-6  
Sweep tested 5 MHz to 1 GHz.  
66% 35 115  
22 AWG  
(7/30)  
0.030"  
Alum. in  
Polyester Foil  
(100%)  
Single:  
2
shielded  
twisted  
pairs  
0.046 1.2  
red and black,  
green and white  
with gray  
fluorocopolymer  
jacket  
60 °C  
conductor-  
conductor  
0.76 mm,  
17 ohms/  
1k ft,  
56 ohms/  
1 km  
Tinned Cu  
62  
203  
Min. bend radius: 7.0"  
17 ohms/  
1k ft,  
56 ohms  
1 km  
conductor-  
conductor,  
connected to  
shield  
for each pair  
Overall:  
0.350 8.9  
blue  
02 December, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edimax Technology Network Card HP 5102 User Manual
Edimax Technology Switch ES 3116RE+ User Manual
Escali Scale Pana User Manual
Extron electronic Switch FOX T USW 103 User Manual
Fellowes Paper Shredder FS 3 User Manual
Fender Speaker CHAMPION 20 User Manual
Gamber Johnson Laptop Docking Station CF53 User Manual
Gefen Portable Generator GTB HD SIGGEN User Manual
GE Monogram Refrigerator ZDOD240 User Manual
GE Washer DSKS333 User Manual