PERFORMANCE
DATA SHEET
WATER TREATMENT PRODUCTS
1040 Muirfield Drive • Hanover Park, IL 60133 • 630.307.3000 • FAX 630.307.3030
MH AND MH2 WATER FILTERS
MH Cartridge Part No. EV9613-01 (1-pack)
Part No. EV9613-06 (6-pack)
OPERATING SPECIFICATIONS
• Pressure requirement: 10-125 psi (0.7-8.6 bar), non-shock
• Temperature: 35-100° F (2-38° C)
MH2 Cartridge Part No. EV9613-21 (1-pack)
Part No. EV9613-26 (6-pack)
NSF Listed Systems
QC7I Single - MH
QC7I Single - MH2
QC7I Twin - MH
QC7I Twin - MH2
QC7I Triple - MH
QC7I Triple - MH2
QC7I Quad - MH
QC7I Quad - MH2
Max. Flow Rate
1.67 gpm (6.3 lpm)
1.67 gpm (6.3 lpm)
3.3 gpm (12.6 lpm)
3.3 gpm (12.6 lpm)
5.0 gpm (18.9 lpm)
5.0 gpm (18.9 lpm)
6.6 gpm (25.3 lpm)
6.6 gpm (25.3 lpm)
Capacity
Space Requirements*
29" H x 51⁄2" W x 5" D
29" H x 51⁄2" W x 5" D
25" H x 11" W x 5" D
25" H x 11" W x 5" D
25" H x 15" W x 5" D
25" H x 15" W x 5" D
29" H x 24" W x 5" D
29" H x 24" W x 5" D
9,000 gal (34,050 L)
9,000 gal (34,050 L)
18,000 gal (68,100 L)
18,000 gal (68,100 L)
27,000 gal (102,150 L)
27,000 gal (102,150 L)
36,000 gal (136,200 L)
36,000 gal (136,200 L)
FEATURES
• Finely polishes treated water to premium quality.
• Reduces chlorine taste and odor.
• Reduces dirt, rust, asbestos fibers, and other particulates
including oxidized iron, manganese, and sulfides.
• Reduces parasitic protozoan cysts such as Giardia, Entamoeba,
and Cryptosporidium.
* Includes 21⁄2” clearance under unit for cartridge change
• Reduces common earthy, moldy, fishy tastes and odors
• Inhibits limescale build-up in ice machines – As tested by
Everpure.
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified above.
Actual performance may vary depending on influent water
conditions.
• MH2 cartridges are treated with bacteriostat to effectively reduce the
growth of bacteria on the filter media. Not Performance Tested or
Certified by NSF.
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF/ANSI*
This system has been tested according to NSF/ANSI 42 and 53 for the
reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to
a concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI 42 and 53.
Influent Challenge
Concentration
Max. Permissable Product
Water Concentration
Reduction
Minimum
Average
Substance
Requirements Reduction Reduction
Standard 42—Aesthetic Effects
Chlorine
2.0 mg/L ± 10%
≥ 50%
≥ 85%
87.8%
99.2%
Particulate,
Class I
particles 0.5
to <1 µm
• To determine NSF Model Name, combine HEAD NAME +
at least 10,000
particles/mL
Standard 53—Health Effects
Turbidity
Asbestos
Cyst
11 ± 1 NTU
0.5 NTU
95.4%
99.87%
99.99%
97.2%
99.87%
99.99%
System Tested and Certified by NSF International against
NSF/ANSI Standards 42 and 53 for the reduction of:
107 to 108 fibers/L > 10
micrometers in length
99%
Standard No. 42 —
Aesthetic Effects
Chemical Reduction
Minimum 50,000/L
99.95%
Taste and Odor
Chlorine
Mechanical Filtration
Particulate Class I: 99.2% reduction of particles
one-half micron and larger in size
* Tested using flow rate = 1.67 gpm; pressure = 60 psig; pH = 7.5 ± 1;
temp. = 20° ± 3°C
† NTU = Nephelometric Turbidity Units
Standard No. 53 —
Health Effects
Mechanical Filtration
Turbidity
Cyst
Asbestos
GENERAL INSTALLATION/OPERATION/MAINTENANCE
REQUIREMENTS
• Install vertically with cartridge hanging down
• Use minimum length of tubing possible
• Flush to drain for 5 minutes at full flow
• Replace cartridges when capacity is reached or when flow
becomes too slow, but at least annually.