OWNER’S MANUAL
Model EP722
120V., 60Hz., 10.8 Amps
For information or assistance:
EURO-PRO Operating LLC
94 Main Mill Street, Door 16
Plattsburgh, NY 12901
Download from Www.Somanuals.com. All Manuals Search And Download.
GETTING TO KNOW YOUR VACUUM
FOR REPLACEMENT FILTER INFORMATION
for Model EP722
Call:
1-866-98SHARK (1-866-987-4275)
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
or
Replacement HEPA filter SKU# XSH722
FOR TECHNICAL SUPPORT
for Model EP722
In U.S.: 1 (866) 805-6850
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
Please Note:
The HEPA Dust Cup Filter may be washed. We recommend that this be done once a
month or when suction appears reduced .
To wash your HEPA Dust Cup Filter, hold filter cartridge by frame flange, flange side
up and rinse under water. When finished, shake off excess water. Do NOT wash in
dishwasher.
It is important that when you wash the HEPA dust cup filter, you allow it to air dry
COMPLETELY before using again. We recommend 24 hours to air dry. DO NOT DRY
IN DRYER.
IMPORTANT: Both the Pre-Motor and the Micro Exhaust filters should be replaced
every 6 months or sooner if required.
1. Hose
9. Telescopic Tube
2. Cord Rewind Button
3. Power On/off Button
4. Handle
10.Floor to Carpet Brush
11.Hand Held Air Driven Turbo Brush
12.Upholstery Brush
13.Dusting Brush
All filters should be checked regularly for signs of damage, preferable after each
cleaning task. The filters must be replaced immediately if they become damaged.
Always disconnect the vacuum from the electrical outlet when checking the filters.
5. Dust Cup
6. Air Intake Duct
7. Air Driven Turbo Brush
8. Dust Cup Handle
14.Crevice Tool
15.Shoulder Strap
Important:
This vacuum cleaner is equipped with a motor protective thermostat. If for some
reason your vacuum overheats, the thermostat will automatically turn the unit off.
Should this occur, unplug the vacuum from the wall outlet and turn off the switch.
Empty the dust cup, "TapClean" the dust cup filter and check for blockages in hose
and suction inlet. Allow the unit to cool for a minimum of 45 minimum prior to restarting
the unit. To restart, re-plug the vacuum into the wall socket and turn the switch back
on.
Technical Specifications
Voltage:
Power:
120V., 60Hz.
10.8 Amps, 1300 Watts
2
9
Download from Www.Somanuals.com. All Manuals Search And Download.
PRECAUTIONARY MEASURES
OPERATING INSTRUCTIONS
Motor Thermostat
Important: This vacuum cleaner is
equipped with a motor protective
Flat & Upright Parking Position
Important: If the suction opening of the unit, the hose or the chrome telescopic tube
are BLOCKED, switch off the vacuum cleaner and remove the blocking
substance before you start the unit again.
Please note that your vacuum cleaner
can be conveniently placed in a space
saving vertical parking position or in a
convenient flat parking position.
thermostat. If for some reason your
vacuum overheats, the thermostat will
automatically turn the unit off. Should this
occur, unplug the vacuum from the wall
outlet and turn off the switch. Empty the
dust cup, "TapClean" the dust cup filter
and check for blockages in hose and
suction inlet. Allow the unit to cool for a
minimum of 45 minimum prior to
4. When pulling out the power plug
from the wall outlet, pull the plug
not the power cord.
1. Do not operate the vacuum
cleaner too close to heaters or
radiators.
1. Place unit on its side. Slide floor
nozzle into locking position with
receptacle which rests on top of unit.
2. While laying flat on 3 wheels, slide
floor nozzle into locking position
with receptacle which rests on the
rear side of the unit.
restarting the unit. To restart, re-plug the
vacuum into the wall socket and turn the
switch back on.
Attaching the Shoulder Strap
5. Do not pick up anything that is
burning or smoking such as
Use the hooks to attach the shoulder
strap to the vacuum cleaner.
2. Before inserting the power plug
into the wall outlet, make sure that
your hands are dry.
cigarettes, matches or hot ashes.
First pass the flexible hose through
the loop of the shoulder strap and
then attach the two hooks to the
strap hookup holes at the bottom of
the vacuum cleaner as shown in
illustration below.
6. Do not use without all filters in place.
Note: This vacuum cleaner is equipped
with a plug and power cord that retract
automatically. If the cord or plug get
damaged, it must be replaced by a
qualified technician.
3. Before you start vacuuming,
make sure to remove large or
sharp objects that might
Warning: Hold the plug when
rewinding the cord. Do not allow the
cord to whip when rewinding.
damage the dust bag.
3
8
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Changing the Pre-Motor Filter
Assembling Your Vacuum Cleaner
9. Reassemble the debris screen to the
HEPA filter cartridge and replace into
dust cup (container). Ensure that the
filter assembly is completely seated
inside the dust cup (container).
4. Fitting the Floor to Carpet
• Filter should be cleaned at least twice
a year or when it becomes visibly solid.
• Always operate the cleaner with the
filter installed.
• Disconnect from electrical outlet before
cleaning the filter.
Brush or the Air Driven Turbo
Brush to the Telescopic Tube
Note: Always remove the power plug
from the wall outlet before assembling or
removing accessories.
Push the telescopic tube into the
desired floor brush as show in the
illustration below.
1. Attaching the Flexible Hose
into the Vacuum
1. Lift dust cup handle to remove
dust cup.
2. Remove the filter from the filter
grill.
Connect the flexible hose into the air
intake duct. Push in until you hear a
“click”, indicating it is in its locked
position.
Telescopic
Tube
To remove the flexible hose reverse
the operation.
10.Attach the dust cup (container) to the
vacuum.
Floor to Carpet
Nozzle
5. Air Driven Turbo Brush
The efficiency of your Air Driven
Turbo Brush depends on the bristle
brush rotating at high speed. Strong
air suction is needed to accomplish
this. In order to endure that
maximum air suction is maintained,
please read the following instructions:
Empty the Dust Cup frequently during
use.
Always “TapClean” the HEPA dust
cup filter and debris screen each time
the dust cup is emptied.
Ensure that the rotating bristle brush
is kept free of hair and string.
Inspect the turbine regularly to ensure
that the air passage is free of dirt and
debris.
PLEASE NOTE: The white pleated
filter material in the HEPA Dust Cup
Filter will discolor over time -This is
NORMAL and will NOT affect the
performance of the filter. If the HEPA
Air Intake Duct
3. Replace with a new filter and reinstall
in vacuum.
Changing the Micro-Exhaust
Filter
2. Fitting the Telescopic Tube
to the Curved Wand / Hose
Dust Cup Filter
Fig. A
•
•
Extension
is properly
"TapCleaned”
after each use
and suction
does not return
to 100%, then
we suggest that
the HEPA filter
be “TapCleaned”
vigorously until no
Wash once
a month or
when
suction
appears
reduced
Push the telescopic tube into the
curved wand / hose extension, as
shown in the illustration below.
•
•
1. Remove the exhaust filter grill by
pulling the locking tabs towards
you.
2. Remove the used micro-exhaust
filter.
3. Insert a new micro-exhaust filter
and replace the filter grill.
Warning: Allow 24
hours for drying before
replacing in unit.
more dust can be removed, then
rinsed under the faucet and allowed to
dry for 24 hours before refitting into
the vacuum. (Fig. A) This should be
done once a month or when
Hand Held Air Driven
Turbo Brush
IMPORTANT: Both the Pre-Motor and
the Micro Exhaust filters should be
replaced every 6 months or sooner if
required.
IMPORTANT: All filters should be
checked regularly for signs of
damage, preferable after each
cleaning task. The filters must be
replaced immediately if they become
damaged.
3. Extending the Chrome
suction appears to be reduced.
Telescopic Tube
CAUTION: The suction hole must be
open, free of any obstructions at all
times. Otherwise, the motor will overheat
and could become damaged.
Push forward on the plastic button
and pull the inner chrome tube
outward.
Air Driven Turbo
Brush
Important: Do NOT use the HEPA filter
cartridge without the debris screen in
place.
Plastic
Knob
Always disconnect the vacuum from
the electrical outlet when checking the
filters.
7
4
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Cleaning & Changing the
HEPA Dust Cup Filter
Warning: Always unplug the unit from
electrical outlet before opening the Dust
Cup (container).
Important: Do NOT use the HEPA filter
cartridge without the debris screen in
place.
Crevice Tool, Upholstery and
Dusting Brush
3. To rewind the power cord,
press the cable rewind button
with one hand and guide the
power cord with the other hand to
ensure that it does not whip
causing damage.
4. Take the HEPA dust cup filter
out of the dust cup, do not let
dust fall out of dust cup.
1. Crevice Tool
For radiators, crevices,
corners, baseboards and
between cushions.
Cord Rewind
2. Dusting Brush
The dusting brush is used for
the furniture, venetian blinds,
books, lamp shades and
shelves.
Warning: After each Use - Always
remove the Filter Debris Screen from the
HEPA Dust Cup Filter, then vigorously
“TapClean” HEPA Filter until no more
dust can be removed.
Yellow
Symbol
Red
Symbol
3. Upholstery Brush
5. Take the dust cup and dispose
of the dust inside.
The dusting brush is used
for the furniture.
IMPORTANT, Please Note : The
Warning: Hold the plug when rewinding
the cord. Do not allow the cord to whip
when rewinding.
“TapClean” HEPA Dust Cup Filter &
Debris Screen will stop most of the tiniest
dust particles and airborne allergens from
re-entering the air you breathe. In fact it
stops 99.97% of all particles as small as
0.3 microns - many times smaller than a
human hair!!! Because of this incredible
filtration performance, the HEPA Dust Cup
Filter will quickly accumulate, inside the
white filter folds, many fine dust particles
that are difficult to see but which will
eventually block or reduce your suction
power - if not cleaned properly. This can
cause the motor to overheat and the re-
settable thermostat to trip. (Should this
happen turn off the switch, unplug the unit
and allow unit to cool down. Clean the
HEPA Filter and Debris Screen as
Warning: To reduce the risk of electric
shock, the power cord must be
disconnected before removing the dust
cup, dust cup filter,changing the filters or
performing maintenance/trouble shooting
checks.
Note: Before using the appliance,
unwind a sufficient length of cable and
Insert the plug into the wall socket. A
yellow mark on the power cord shows the
ideal cable length. Don’t pull the power
cord beyond the red mark.
Cleaning Air Driven Turbo Brush
Locking Latch
Tilt
Upwards
6. Separate the debris screen from the
HEPA filter cartridge by grasping the
debris screen with one hand and the
filter frame with the other and pull
apart.
Turbine
Power Cord
Your vacuum cleaner includes a power
cord, which is automatically retractable.
To extend your power cord, pull from
rear and extend to desired length.
When cleaning is finished, first switch
off power and disconnect plug from
electrical outlet. Then press on cord
rewind button. If the cord does not fully
retract, pull it out again and then press
on cord rewind button.
1. Slide locking latch forward then tilt the
top housing of the brush upwards. The
top housing is hinged and will tilt up
approximately 45° only.
2. Inspect turbine wheel and air passage
for debris and/or blockage. Remove
debris if present.
3. Inspect the rotating brush for built-up
hair or string. If present, remove by
carefully cutting with scissors. Avoid
damaging or cutting bristles.
4. Once clean, close the top cover of the
turbo brush and slide the locking latch
toward the rear of the brush to lock.
HEPA Filter
Debris Screen
described in this section, then reconnect
unit and proceed with vacuuming.)
7. Vigorously “TapClean”
the HEPA Dust
Cup Filter on a
hard surface until no
more dust is observed
falling out from
between the pleats of
the filter. Please note
that on the under side of the HEPA
dust cup filter there is a small brush
which you can use to brush out the
pleats of the filter.
1. Push the Power On/Off switch
to the OFF position to
disconnect the power.
2. Remove the flexible hose.
3. Remove the dust cup by lifting
the dust cup handle. See
illustration below.
1. Insert the power plug into the wall
outlet.
2. Press the Power On/Off Switch to
Dust Cup Handle
activate the vacuum cleaner.
Power On/Off Button
8. “TapClean” the Debris
Screen or rinse under
a faucet until clean.
Remember that
the Debris Screen
must be completely
dry before reinstalling
in the vacuum.
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.
|