Elation Professional Video Games ART 10 User Manual

ART SSC  
SOLID-STATE CONTROL  
ART SSC + ART IO  
MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Introduction..................................................................................................... 2  
Art SSC........................................................................................................ 2  
Art IO.......................................................................................................... 2  
Further Help................................................................................................. 3  
Setting up........................................................................................................ 4  
Mounting...................................................................................................... 4  
Power.......................................................................................................... 4  
Network....................................................................................................... 5  
eManager Software Tool................................................................................. 7  
Protocols..........................................................................................................9  
DMX-512...................................................................................................... 9  
Art-Net.........................................................................................................9  
OSC........................................................................................................... 10  
UDP........................................................................................................... 10  
GPI............................................................................................................ 10  
eTouch........................................................................................................11  
SMPTE........................................................................................................11  
MIDI.......................................................................................................... 12  
GPO........................................................................................................... 12  
RS-232.......................................................................................................12  
Art SSC Web-Interface..................................................................................... 13  
Home......................................................................................................... 13  
Console...................................................................................................... 14  
Recorder.....................................................................................................18  
Show Control.............................................................................................. 21  
Actions....................................................................................................... 23  
Monitors..................................................................................................... 26  
Settings......................................................................................................27  
Art IO Web-Interface....................................................................................... 31  
Home......................................................................................................... 31  
Show Control.............................................................................................. 32  
Monitors..................................................................................................... 34  
Settings......................................................................................................35  
© 2011-2012 Elation Professional  
All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic,  
electronic, or mechanical, including photocopying, recording, taping, or information storage and  
retrieval systems - without the written permission of the publisher.  
While every precaution has been taken in the preparation of this document, the publisher and the  
author assume no responsibility for errors or omissions, or for damages resulting from the use of  
information contained in this document or from the use of programs and source code that may  
accompany it. In no event shall the publisher and the author be liable for any loss of pro%t or any other  
commercial damage caused or alleged to have been caused directly or indirectly by this document.  
Due to the dynamic nature of product design, the information contained in this document is subject to  
change without notice. Revisions of this information or new editions may be issued to incorporate such  
changes.  
Products that are referred to in this document may be either trademarks and/or registered trademarks  
of the respective owners. The publisher and the author make no claim to these trademarks.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Thank you for choosing the Art SSC and Art IO. This manual discussing setting up the units and  
programming the lighting cues, show-control-actions and various other features.  
The Art SSC and Art IO share for a large part the same functionality. When discussing those functions  
this manual will refer to the 'device'; this means both the Art SSC and Art IO.  
Art SSC  
The Art SSC is solid-state lighting controller, designed without any moving parts, it is build for reliability  
and durability.  
The unit is aimed at providing a control solution for  
(semi-)permanent lighting projects. The Art SSC primary  
control signal is DMX-512, the protocol used for  
entertainment, theatre and most LED lighting %xtures.  
Next to DMX-512 this controller also supports a range of  
other protocols; allowing communication with various  
other equipment.  
An internal web-server provides the web-interface through which you can program the Art SSC. A  
modern browser is required to access this web-interface during set-up. A browser or computer is not  
required for standalone use after the set-up.  
It features:  
2 independent, optically isolated DMX-512 outputs  
optically isolated DMX-512 input  
MIDI in, through and out (with MTC support)  
SMPTE time-code input  
GPI port with 4 contact closures  
Ethernet port with support of Art-Net, OSC & UDP  
Lighting controller with 256 cues  
DMX-512 and Art-Net recorder with 16 memories  
Real-time clock scheduling  
eTouch compatibility  
Art IO  
The Art IO is an expansion module in the Art SSC. It o>ers interfacing to digital and analogue inputs and  
digital outputs and supports various protocols like DMX, RS-232, OSC, UDP and Art-Net.  
The Art IO features 8 inputs that can be individually  
con%gured as digital or analogue input. The 8 outputs on  
the Art IO are relay-switched and can handle 3 Amp. The  
digital outputs can be used to switched various other  
devices like A/V equipment, blinds or heavy-duty relays.  
Additionally, the Art IO is %tted with a DMX-512 port that  
can be con%gured as input or output, and a bi-directional  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 port. Through its network port, the Art IO also supports OSC, UDP and Art-Net protocols that  
can be used for triggering and conversion.  
The compact and versatile Art IO is the ideal expansion for the Art SSC in projects that demand more IO.  
Furthermore, Art IO is equally well suited for standalone IO interfacing or working together with any  
third-party show control system.  
It features:  
8 inputs, switch-able between digital or analogue  
8 output, relay-switched  
optically isolated DMX-512 port, switch-able between input or output  
RS-232 port  
Ethernet port with support of Art-Net, OSC & UDP  
eTouch compatibility  
Further Help  
If, after reading this manual, you have further questions then please consult the website at  
http://forums.elationlighting.com/ for more technical support.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting up  
This chapter discusses the steps to set up the Art SSC and Art IO to start programming.  
Mounting  
The device can be placed desktop or it can be DIN rail mounted  
DIN Rail  
The device is prepared for DIN Rail mounting by using the 'DIN rail  
holder TSH 35' from Bopla (Product no. 22035000).  
This adapter is – amongst others – available from:  
Farnell / Newark (order code 4189991)  
Conrad (order code 539775 – 89)  
Distrelec (order code 300060)  
Kensington Lock  
You can secure your device by using a Kensington style laptop lock.  
Power  
The Art SSC and Art IO require a DC power supply between 9 and 12  
Volts with a minimum of 500mA. The 2,1 mm DC is center-positive.  
Furthermore, the Art IO is Power-over-Ethernet (POE) enabled. It requires POE Class I.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network  
During programming a network connection is required between the device and computer. Connect the  
Ethernet port on the device to the Ethernet port on your computer by using a RJ-45 cable. Alternatively,  
you can connect the device and the computer via a network switch. The Art SSC's Ethernet port is auto-  
sensing so it does not matter whether you use a cross or straight cable.  
The factory default IP address is 192.168.1.10 with the sub-net mask set to 255.255.255.0. Make sure your  
computer is in a valid address range, e.g. set your computer to IP 192.168.1.9 with a sub-net mask of  
255.255.255.0.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Then open a browser on your computer and go to http://192.168.1.10. You should see the following  
page:  
Art SSC home page  
Art IO home page  
The settings page allows you to change the IP address and sub-net. Make sure that all equipment on  
your network have unique IP addresses.  
By pressing the reset button on the device for 3 seconds or more, you will recon%gure the unit to the  
factory default IP address and sub-net mask. No other settings will be changed.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
eManager Software Tool  
A special software tool called eManager has been developed to manage (multiple) devices. This tool is  
available on MS Windows, Mac OS X and Ubuntu Linux is available via our website, free of charge.  
eManager allows you to:  
Identify a speci%c device (in a multi device set-up) by blinking it's LED  
Change IP address and subnet  
Set the Art SSC's date and time (your computer's date and time will be used)  
Perform %rmware updates  
Do a factory reset that will erase all user data in the device and will restore the default settings.  
Calibrate the Art SSC's internal real-time clock  
Make a backup of all the data in the device.  
Blink  
You can set the device's LED to blink fast for identifying a particular unit amongst multiple devices. The  
blinking is enabled by double-clicking on a device in the 'Devices' list or by selecting a device and then  
clicking the 'Blink' button.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set Date & Time  
You can quickly copy your computer's date and time to the Art SSC by selecting a device and clicking the  
'Set Date & Time' button.  
Upgrade Firmware  
To upgrade the %rmware, %rst select your device and press the 'Upgrade Firmware' button. The  
dialogue allows you to select from the %rmware available.  
Caution: Make sure the power to the device is uninterrupted during the upgrade process.  
Factory Defaults  
The memory containing all user data like cues, recordings and actions is completely erased and all  
settings are reverted to their defaults by pressing the 'Factory Defaults' button. This action does not  
a>ect the device's IP settings.  
RTC Calibration  
In case the time in your Art SSC's Real-Time Clock (RTC) drifts then you are advised to perform a  
calibration. Start the calibration process by pressing the 'Start RTC Calibration' button. Then wait a  
while for the measurement to take place. The longer you wait the more accurate the calculation will be,  
we recommend somewhere between 30 to 60 minutes. Then press the 'Stop RTC Calibration' button a  
dialogue will inform you of the results. Press OK to apply the calibration value.  
Backup  
You can make a backup of all the programming data inside the device. This backup %le (an XML) is saved  
on your computer's hard-disk and can be easily transferred via e-mail or USB stick. You can restore the  
backup via the 'Restore' button.  
The backup %les can be found at folowing location:  
Windows XP  
Windows Vista  
Windows 7  
C:\Documents and Settings\[username]\My Documents\Elation\eManager\Backups  
C:\Users\[username]\Documents\Elation\eManager\Backups  
C:\Users\[username]\Documents\Elation\eManager\Backups  
/Users/[username]/Elation/eManager\Backups  
Mac OS X  
Ubuntu Linux  
/home/[username]/Elation/eManager\Backups  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Protocols  
The Art SSC and Art IO are %tted with several communication ports and supports various protocols. This  
chapter describes these protocols.  
DMX-512  
The Art SSC has two DMX outputs ports and one input. Connect your lighting %xtures either to the DMX  
OUT A port or DMX OUT B. Use a 5-pin XLR cable to connect the Art SSC's DMX OUT port to the %rst  
%xture, from then on daisy-chain to all other %xtures.  
The Art IO has one DMX port which can be set either as input or as output. The DMX signals are  
available on the screw terminals. You can create an adapter cable for connecting to XLR connectors  
using the pin-out below.  
3 Pin Adapter  
If your cabling or %xtures are using a 3-pin XLR connector then you can obtain - or  
create yourself - a 5-to-3-pin adapter.  
For both 5-pin and 3-pin connectors the pin-out is:  
1 = GND  
2 = Data-  
3 = Data+  
(on the 5-pin XLR pin 4 & 5 are not connected)  
Cable  
Use a shielded twisted pair cable for DMX cabling. The cable should be terminated with an 120 Ohm  
resistor.  
Overcoming DMX-512 Limitations  
DMX-512 is a very successful protocol with, however, a few  
limitations. The maximum number of attached devices is limited  
to 32 and they all have to be connected in bus-topology having  
one cable running via each device. Furthermore, a DMX cable  
should not be longer than 300 meters.  
The DMX Branch/4 from Elation Professional helps tackle those  
inconvenient limitations of DMX-512. The Splitter takes a DMX  
signal and sends it out again on its 4 DMX output ports allowing a  
star-topology for ePcient cable usage. Each output port is capable of driving 32 more devices. The  
Splitter can also function as a signal booster as each port supports another 300 meter long connection.  
Art-Net  
The Art-Net protocol primarily transfers DMX-512 data over Ethernet. The high bandwidth of a Ethernet  
connection allows Art-Net to transfer up to 256 universes. The Art SSC supports 2 universes outgoing  
Art-Net and 2 universes incoming.  
The broadcast messages sent out by Art-Net do put a certain load on the network, therefore it is  
recommended to disable Art-Net when not in use.  
Additional to transmitting DMX-512 data, Art-Net can also be used for transferring time-code  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
information.  
OSC  
Open Sound Control (OSC) is a protocol for communicating between computers, software and various  
multi-media type devices. OSC uses the network to send and receive messages, it can contain MIDI,  
time-code and custom information.  
There are apps available for creating custom-made  
user interfaces on IOS (iPod, iPhone, iPad) and  
Android. These tools allow you to program fool-  
proof user-interfaces for controlling the device.  
E.g. TouchOSC from  
There is a TouchOSC layout available from  
to control the recorder playbacks and select cues in the lighting console of the Art SSC. This layout  
works in conjunction with the 'OSC' templates, as discussed on page 22.  
Other templates are available to use the Art SSC as a converter between OSC and MIDI.  
UDP  
UDP (User Datagram Protocol) is a simple protocol for sending message across the network. It is  
supported by various media devices like video projectors and show controllers.  
The device can send and receive UDP messages. The UDP message contains a NULL terminated ASCII  
string of maximum 15 characters. UDP can be received by adding the UDP source action-list in the Show  
Control page. Enter the expected ASCII string as the action's trigger. UDP messages can be send by  
adding a UDP task to any action. Parameter 1 allows you to enter the ASCII string and parameter 2 will  
contain the destination IP address and port number.  
GPI  
The General Purpose Inputs (GPI) port on the Art SSC di>ers from the ports on the Art IO.  
Art SSC  
The GPI port features 4 contact-closure ports. It allows you to attach physical switches, sensors or other  
equipment and have the ports trigger events in the Art SSC. You can set the port to 'Normally Open' or  
'Normally Closed' in the Show Controller (see page 23).  
The GPI's RJ-45 has the following pin-out:  
If your project requires more than 4 GPI contacts then you can  
expand the GPI ports by connecting one or more Art IO modules to your Art SSC. The module can be  
connected through OSC, UDP, Art-Net or DMX.  
Art IO  
The Art IO features 8 inputs that can be individually con%gured as digital or analogue input. Set as digital  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
input, it allows for an easy connection with for example physical switches and sensors. When set to  
analogue, it supports 0-10V and 1-10V inputs; ideal for connecting to household dimmers.  
eTouch  
eTouch is a software application that can trigger events within the device. eTouch is equipped with a  
user interface especially designed for use with Touch Screens. This makes it an ideal companion to the  
device when applied in a %xed installation, using eTouch to control recordings and select cues, or any  
other feature in the Art SSC or Art IO.  
eTouch is designed to have no editing capability, making it a fool-proof interface that can safely be  
presented to non-lighting technicians.  
eTouch is available on Windows, Mac OS X and Ubuntu Linux and can be downloaded from  
SMPTE  
- Art SSC only -  
SMPTE is time-code signal which can be used to synchronize audio, video, lighting and other e>ects.  
SMPTE information can be transferred through various media like audio channels, video signals, MIDI,  
etc.  
The Art SSC supports receiving LTC SMPTE that is transferred as an audio signal.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MIDI  
- Art SSC only -  
The MIDI protocol was intended for inter-connecting musical devices such as synthesisers and  
sequencers. This protocol is also very suitable to send triggers from one device to another and is often  
used to synchronise audio, video and lighting equipment.  
There is also a large collection of MIDI control surfaces available; user-interface consoles with knobs,  
(motor-)faders, rotary-encoders, etc.  
The Art SSC also supports the time-code signal  
(MTC) which is embedded into MIDI.  
GPO  
- Art IO only -  
The 8 General Purpose Outputs (GPO) on the Art IO are relay-switched and can handle 3 Amp. The  
digital outputs can be used to switched various other devices like A/V equipment, blinds or heavy-duty  
relays.  
RS-232  
- Art IO only -  
The Art IO is %tted with a bi-directional RS-232 communication port. This allows the Art IO to be  
triggered by ASCII strings received on the RS-232 port and it can send out ASCII strings in response to an  
event.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Art SSC Web-Interface  
The Art SSC has an inbuilt web-server. All the programming of the Art SSC is done via its web-based  
User-Interface. This 'website' has multiple pages and they are discussed in this chapter.  
Home  
This is the opening page of the web-interface. It gives a read-only overview of the settings and values;  
nothing can be changed here.  
Notice the status bar at the bottom of the page, this bar o>ers a real-time display of the Art SSC's  
primary properties. This bar remains visible on each page. The GPI bits indicate 'O' when the contact is  
open and 'I' when the contact is closed.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Console  
The Console page allows you to program and manually playback lighting scenes.  
Overview  
A Cue is a lighting scene, a state at which all DMX channels are set to a speci%c value. A sequence of  
multiple Cues - running one-by-one – is called a Cue-list. The Lighting Console function features as 1 Cue-  
list containing 256 Cues. Each Cue stores the values for all 1,024 DMX channels. The number of Cues is  
%xed, however, Cues can be left unused.  
Run Mode  
The Lighting Console can be set in either PLAY or EDIT mode. The di>erence between the modes is the  
EDIT mode ignores the fade, hold and link values. The EDIT mode is more convenient during  
programming the Cues.  
Unit  
A DMX channel can be set between 0 (minimum) and 255 (maximum). The DMX levels are shown in  
these decimal values if the UNIT is set to DEC. When UNIT is set to % the levels are shown in the range of  
0% and 100%.  
The UNIT setting also inTuences how you enter the values via the Command Line interface. E.g. if you  
would like to set a channel to the maximum level you would type in value '255' when the unit is set DEC  
and you would type in '100' when it was is set to %.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming a Cue  
First enable the EDIT mode and select the desired Cue by using the GO+ and GO- buttons. You see the  
number of the current Cue in the bottom left-hand corner of the screen.  
Use the command line interface (CLI) to change the value of the channel. The CLI is known from theatre  
lighting consoles and provides a fast way of setting values for one or multiple channels.  
Examples of the CLI's usage are:  
Command  
Function  
1 @ 50 <ENTER>  
Sets channel 1 at 50% (or at DMX value 50 when DEC unit is  
selected)  
1 + 2 @ <FULL>  
Sets channel 1 and 2 at maximum value  
Sets channels 1 till 3 at minimum value  
Sets channels 1, 2,3, and 5 at minimum value  
1 <THRU> 3 @ 0  
1 <THRU> 3 + 5 @ 0  
<ALL> @ 100 <ENTER>  
Sets channels 1 till 1024 at 100% (or at DMX value 100 when  
DEC unit is selected)  
1 @ + 10 <ENTER>  
Increases channel 1 value with 10  
Decreases all channels' value by 20  
<ALL> @ – 20 <ENTER>  
Capture a Cue  
Alternatively to programming a Cue through the CLI it is also possible to record a Cue from the DMX  
input port or incoming Art-Net universes.  
To capture from DMX, simply connect your external DMX-512 source and set it to output the desired  
Cue, then press the DMX Capture button. Only the %rst 512 channels will be recorded, channels 513 till  
1024 are left unchanged.  
For capturing from Art-Net please make sure that the universe settings for incoming Art-Net match the  
universes at your Art-Net source. Press the Art-Net Capture button and all 1,024 channels are recorded  
in the Cue.  
Timing  
You can specify the cross-fade time between two Cues by setting the Cue's fade time (expressed in  
seconds). Also you can determine for how long the Cue should be active before advancing to the next  
Cue by setting the hold time. If the hold time is set to 0, the Cue is set to Halt and will not automatically  
go to the next Cue.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Linking Cues  
When going to a new cue (whether by a manual 'Go+' or automatically by setting a hold time) then by  
default the next cue will be run, as shown in the next diagram.  
You can change this by setting the 'Link+' %eld other than 'none'. When set to a number, this cue will go  
to this speci%ed cue number as the next cue. You can use the link %eld to create loops/chases. See the  
next diagram.  
When you press the 'Go-' button you will go to the previous cue, however, similar to the 'Link+' %eld,  
you can use the 'Link-' %eld to specify a cue to go-back to. Using both link %elds you can create a bi-  
directional loop by which the user could step through a set of cues by using just two buttons (e.g. 2  
physical switches connected via the GPI port that control the 'Go-' and 'Go+' ). As illustrated in the  
following diagram.  
Manual Playback  
Set the Lighting Console to the PLAY mode for manual playback of the Cues. You can use the GO+ and  
GO- buttons for traversing through the various Cues. The JUMP allows you to go to a certain Cue  
directly (without stepping through all intermediate Cues). E.g. If you like to go to Cue 24 you use the CLI  
to type <JUMP>24<ENTER>.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Channel Groups  
It is likely that during programming of the Cues you will often select the same channels, albeit with  
di>erent values. To make the process of selecting channels quicker, the Lighting Console features  
Channel Groups.  
You can store one or more channel numbers in a Group and quickly recall this group by clicking its  
button.  
For example you can program the value of channels 1,2,3,4,6 by entering in the CLI:  
1 <THRU> 4 + 6 @ 50 <ENTER>  
You can also store these channels in Group 1 by typing:  
1 <THRU> 4 + 6 @ <GROUP1>  
Then press the group button to recall Group 1 in order to set the channels:  
<GROUP1> @50 <ENTER>  
Routing  
The DMX values outputted by the Lighting Console can be routed to either or both DMX-512 outlets and  
Art-Net. This can be controlled in the settings page (see page 28).  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recorder  
In the previous chapter you've read that you can record a static lighting scene by capturing it into a Cue,  
however, in some cases it will be required to record a dynamic lighting scene that is changing over time.  
Perhaps you need to record pan/tilt shapes for moving lights or record graphical e>ects on a LED  
matrix.  
For these situations the Art SSC o>ers the DMX-512 and Art-Net recording functionality. With it you can  
store both static and dynamic DMX data.  
Capacity  
There are 16 memories that can hold a recording. When recording all 1,024 channels are stored, even  
though some channels might not be used and remain at zero. The Art SSC utilizes a compression  
technique to %lter out all channels that do not change. Therefore it is not possible to exactly state the  
maximum duration a memory can hold; it depends on the DMX data itself. When many channels change  
often the compression is less e>ective. When only a few channel change a little the compression is very  
e>ective.  
Furthermore, the refresh rate setting will determine how many samples of the data are taken per  
second and stored in memory. This setting varies between 1 and 40 frames per second. 40 Hz gives  
maximum quality in terms of smooth dimming curves. 5 Hz is quite a low value but very useful for  
recording very slow DMX changes that in themselves might not change faster anyway. Often a setting  
of 20 Hz will do %ne, while allowing for twice as long recording as a 40 Hz setting.  
Theoretically, the memory will hold for at least XXX seconds data in the worst-case situation, i.e. all 1,024  
channels change each frame, recorded at 40 Hz. More realistic, a set-up using 100 dimmer channels  
changing regularly, recorded at 30 Hz, may last XXXXX minutes.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
By default, the recorder has 16 memories. You can reduce the number of memories in the settings page.  
When you reduce the number of memories each memory will have more storing capacity, as the total  
capacity used by all memories remains the same.  
Recording  
To make a recording %rst select one of the memories. You may give it a name now or do this after  
recording. Then set the desired refresh rate and select between DMX and Art-Net for the source. Then  
press the MANUAL RECORD button. When you're ready press the STOP button. If the memory becomes  
full the recording is stopped automatically.  
You can use the CONSOLE RECORD button to simply copy the current output of the Console into a  
recording (this recording will have one DMX frame).  
Alternatively, you can have the recording started and stopped automatically if the timing needs to be  
more precise than manual control. In order to make a 'triggered' recording appoint one DMX channel as  
the trigger channel (choose from 1 till 1,024). Then press the TRIGGERED RECORD button. The memory  
is now ready for recording, but the recording will only start when the trigger channel's value reaches  
above 127. The recording is stopped as soon as the trigger channel goes below or equals 127. This allows  
you to program the value of the trigger channel in your external DMX-512 or Art-Net console and time  
the recording accurately.  
Finally, you can also record a memory in sync with the time-code by using the TIME-CODE RECORD  
button.  
Playback  
Each memory has an intensity value. When the intensity is set to a value other than 0, the memory will  
be played back. The Art SSC is capable of simultaneous playback of 4 memories. When a %fth playback is  
set to playback, Art SSC will automatically stop the oldest playback (the one whose intensity level has  
not altered for the longest time).  
HTP/LTP  
By default the values of all running playbacks are, with its intensity level taken into account, merged  
together according to the Highest Takes Precedence (HTP) principle. The following table illustrates the  
HTP system.  
Playback 1  
0%  
Playback 2  
0%  
Playback 3  
25%  
Merged Output  
25%  
Channel 1  
Channel 2  
Channel 3  
Channel 4  
100%  
0%  
0%  
25%  
100%  
0%  
0%  
0%  
0%  
100%  
25%  
100%  
When set to LTP, only the last activated playback will send out its values. As soon as that playback is  
stopped the one-but-last activated playback will be sending out.  
Time-code  
Normally the memory is played back using the internal timings of the Art SSC. When the 'Time-code'  
check box is enabled, the internal timing is ignored and the playback is synchronised to the time-code.  
Please select a time-code source in the settings page.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loop  
The 'Loop' check box controls whether the playback stops when it reaches the end of the track, or  
whether is should continue looping inde%nitely. The Loop feature is only available when 'Time-code' is  
disabled.  
Routing  
The DMX values outputted by the Recorder can be routed to either or both DMX-512 outlets and Art-  
Net. This can be controlled in the settings page (see page 28).  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Show Control  
Your Art SSC needs to respond to the outside world. With today's ever more demanding lighting  
projects, chances are it needs to respond to various di>erent signals or protocols. The Art SSC supports  
a variety of protocols. In the Show Control page you determine how your Art SSC will respond to which  
signal and what tasks it will perform when triggered.  
The show control consists of action-lists and actions. All the di>erent kind of signals the Art SSC can  
receive are categorized as 'sources'. Each action-list relates to one source and can contain multiple  
actions. Each action details to which speci%c signal it is listening and contains a list of tasks it will  
perform when triggered. Action-lists and actions are further discussed on page 23.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Protocol Conversion  
With many signals coming into the Art SSC and many signal going out, the Show Control page is also the  
place where you can program Conversion between di>erent protocols. For example you can program  
an Art-Net Source and %t it within an Action that sends out DMX-512, thus creating an Art-Net to DMX-  
512 converter.  
Templates  
The Show Control page provides ready-made Templates for several typical action arrangements.  
Templates can be easily copied to the Source list and modi%ed in necessary.  
The following table describes the functionality of the templates.  
Art-Net DMX  
Converts Art-Net input universe 1 to DMX Out A and Art-Net input universe 2 to DMX Out  
B.  
DMX Art-Net  
DMX MIDI  
Converts DMX input to Art-Net output universe 1.  
Converts DMX input to MIDI output. DMX channels 1-128 are converted to CC messages  
on MIDI channel 1. DMX channels 129-256 are converted to CC messages on MIDI  
channel 2. DMX channels 257-384 are converted to CC messages on MIDI channel 3. DMX  
channels 385-512 are converted to CC messages on MIDI channel 4.  
GPI DMX  
GPI port 1-4 is converted to DMX channel 1-4 on DMX Out A.  
GPI port 1-4 is converted to Note On 1-4 messages on MIDI channel 1.  
GPI port 1-4 is converted to OSC “/gpiX” messages.  
GPI MIDI  
GPI OSC  
GPI Art-Net  
MIDI DMX  
MIDI Art-Net  
Art-Net Recorder  
GPI port 1-4 is converted to DMX channel 1-4 on Art-Net output universe 1.  
Converts incoming MIDI to DMX channels.  
Converts incoming MIDI to Art-Net channels.  
Maps the %rst 16 channels of the 'In A' universe to the playback intensities of the  
recorder's memories.  
Touch Screen ꢀ  
Recorder  
Touch Screen layout with faders to control the playback intensities of the recorder's  
memories.  
GPI Console  
Triggering GPI port 1-4 will jump to the corresponding cue in the Console.  
OSC RGBW Example  
OSC actions to match the TouchOSC template that can be downloaded from our  
website. This example assumes a RGBW %xture is connected with starting address 1.  
OSC Recorder  
Controls the playback intensities of the recorder's memories by incoming OSC  
messages. The OSC URI is /trackX, where X is the memory number.  
DMX Splitter  
The DMX signal from DMX Input is sent out on DMX Outputs A and B.  
This template is used for testing the device during the production process.  
Production Test  
eTouch  
Creating a eTouch layout is done by creating a 'Touch Screen' action-list and adding actions. For each  
action you can choose between various controls like buttons and sliders. The order of the actions will  
control the arrangement in eTouch.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Actions  
Programming the show controller involves adding action-list and specifying actions.  
Action-lists  
In the Action-lists table you can include the sources you will be using in your project. You can choose  
from input sources like: DMX, Art-Net, MIDI, GPI, Time-code, Scheduler & OSC. Each source may exist in  
the table only once. Each Action-list can be enabled and disabled.  
Actions  
Within each Action-list you can create multiple Actions. You can create up to 64 Actions system-wide  
and maximum 48 per list. For each Action you specify when it will be triggered and which Tasks it will  
perform when that trigger occurs.  
To change the details of an action, select it and press the EDIT button. This will open the Action page.  
Flank  
For most types of actions you can set the Tank. For example when editing a GPI action, it will be  
triggered only on closing the contact (also known as 'normally open') when the speci%er is set to  
DOWN. When set to UP, the action will be only trigger on opening the contact (a.k.a. 'normally closed').  
Finally, when the speci%er is set to CHANGE, the action will be triggered on both closing and opening of  
the contact.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Trigger  
Specify the exact trigger on which to execute the tasks. In the case of a GPI action, the trigger denotes  
the trigger port number (there are 4 ports on the Art SSC).  
Tasks  
You can specify up to 8 Tasks per Action and a maximum 128 Tasks in total. When triggered, the Tasks  
are performed in the same order as they are listed in the Action. Tasks can control various elements and  
protocols in the Art SSC, such as DMX, MIDI, Art-Net, OSC, Lighting Console's Cues, playback of  
recordings. Tasks can also be used to trigger other Actions, enable or disable action-lists and start/stop  
the internal time-code.  
Because a Task can do a wide variety of things they are organized in di>erent Task 'Types'. When adding  
a task a pop-up window will allow you to choose from the following types:  
Console  
Recorder  
DMX  
Control Cues and other elements found on the Console page.  
Control playback of Recording's and other elements found on the Recorder page.  
Control the DMX channels in the 'Show Control bu>er'. This data can be send out via the  
DMX ports and/or Art-Net. Please set the 'Output Routing' in the Settings page  
accordingly.  
MIDI  
Send a MIDI message.  
OSC  
Send an OSC message.  
Art-Net  
System  
Action  
[obsolete, use DMX in stead]  
Perform miscellaneous tasks like blinking the device's LED.  
Trigger another action.  
Action List  
Timecode  
Control the properties of an Action-list (e.g. Enable check-box).  
Control the time-code properties like selecting the input source or start/stop the internal  
time-code generator.  
Variable  
UDP  
[not implemented yet]  
Send a UDP message.  
GPI  
Trigger the GPI port to read a binary value across all 4 contacts.  
Feature  
For each task you can select a Feature. The choice in Features di>ers for each Type. For example when  
you add a Task with the 'Console' type, you can choose between:  
Go+  
Jump to the next Cue. I f the current cue is number 256 then it will jump to cue 1.  
Jump to the previous Cue. I f the current cue is number 1 then it will jump to cue 256.  
Jump to a speci%c Cue number.  
Go-  
Jump  
Capture from DMX  
Record the channel values from the DMX in port and save it in the current Cue. Because  
there is only one DMX input this will only save the %rst 512 channels.  
Capture from Art-  
Net  
Record the channel values from the Art-Net in universes and save it in the current Cue.  
Capture from Show  
Control  
Record the channel values from the 'Show Control DMX bu>er' and save it in the current  
Cue.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Function  
Each Task also has a Function %eld. The choice of Functions depends on the Task-Type and the selected  
Feature. For example, when you add a Task with the 'Console' Type and set its Feature to 'Jump' then  
you can select of the following Functions:  
Set  
Jump to a Cue number speci%ed in Param1.  
Toggle  
Control  
Jump to between the Cue numbers speci%ed in Param1 and Param2.  
Jump to a Cue number determined by the trigger of this action. If this action was triggered  
by a MIDI messages then the Cue number is determinded by the MIDI value (in case of a  
CC message) or velocity (in case of a NoteOn message).  
Switch  
Switch to between the Cue numbers speci%ed in Param1 and Param2. If the action was  
triggered by a value <50% it will select Param1 and if it's >50% it will select Param2.  
Scheduling  
An important input Source is the Scheduler. The Scheduler uses the Art SSC's internal, battery backed-  
up Real-Time Clock. There are several ways to specify a trigger.  
Date and Time  
You can use the Scheduler to trigger actions on certain  
dates and times. When specifying a date and time it is  
possible to choose 'Don't Care' for each value by  
entering 'X'. E.g. if you set a date and specify 'Don't  
Care' for the year %eld, this Action will be triggered  
each year.  
Weekday and Time  
Sometimes you would like to de%ne a trigger based on  
a day in the week, rather then a speci%c date. The Art  
SSC supports this, it allows to choose any combination  
of weekdays and time.  
Astronomical Clock  
The Art SSC is equipped with an astronomical clock  
that based on the day of the year and position on the  
globe (as con%gured in the settings page) calculates  
the sunrise and sunset times. This allows you to trigger  
events on sunrise or sunset.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Monitors  
The Monitor page presents you with an overview of the Art SSC's incoming and outgoing data. This  
page is useful for checking and debugging your programming.  
The top row of buttons allows for selecting the data stream. In the case of DMX or Art-Net data, you can  
use the buttons on the right to toggle between decimal and percentage notations, and use the up and  
down buttons to step through all the channel pages.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Settings  
In the Settings page you can change various properties of the Art SSC.  
General  
You can change the Art SSC's label. This label can be used to distinguish the unit in a set-up with  
multiple Art SSCs.  
The 'Blink' check-box will Tash the device's LED to help to identify it amongst multiple devices.  
This section also allows you to set the number of Memories in the Recorder. By default this number is  
set to 16. If you would like to store only a few, but larger, recordings then you can lower this number;  
making each memory bigger. All the recorder's memories need to be erased after changing this setting.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Output Routing  
There are three sources that can set DMX/Art-Net data:  
Lighting Console  
Recorder  
Show Control  
The routing settings enables you to determine on which ports the Lighting Console, Recorder and Show  
Control output their data; i.e. the DMX ports, the Art-Net (Ethernet) port or both.  
If more than one source is enabled per DMX or Art-net then the data of those sources is merged  
together via the Highest Takes Precedence (HTP) principle.  
Art-Net  
The Art-Net feature in the Art SSC supports 2 universes out and 2 universes in. You can map each of  
those universes to any of the 256 available universes in the Art-Net protocol. This number is zero-based,  
ranging from 0 up to and including 255.  
The broadcast messages sent out by Art-Net do put a certain load on the network, therefore it is  
recommended to disable Art-Net when not in use.  
Art-Net transmission is switch o> by default, it will be enabled automatically as soon as at least one Art-  
Net check-box is enabled in the Output Routing. Reception is permanently enabled for incoming Art-Net  
data and poll messages.  
Date & Time  
You can set the date and time of the Real-Time Clock (RTC) here. The clock is battery back-up in to keep  
the time during a power failure.  
Location  
The astronomical clock in the Art SSC calculates the sunrise and sunset times based on day of the year,  
latitude, longitude and UTC values.  
The latitude and longitude values de%ne your position in the world and should be entered in degrees.  
The latitude value should be positive for North and negative for South, the longitude should positive for  
East and negative for West. The website http://www.%ndlatitudeandlongitude.com/ can help you %nd  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
the latitude and longitude values for your location.  
The time-zone and perhaps daylight saving time of your location is expressed in the UTC (Coordinated  
Universal Time) value. UTC is – in this context – equivalent to GMT (Greenwich Mean Time).  
For example, Elation' HQ is based in the city of Haarlem, the Netherlands. During the winter we are UTC  
+1 and in the summer during day light saving time we are UTC +2. So, our settings are:  
UDP  
In this section you can set the port number on which the Art SSC will listen out for UDP messages. The  
IP addresses and port numbers for outgoing UDP messages are set in the tasks at the Show Control  
page.  
OSC  
Set the port number on which the Art SSC will listen for OSC messages in this section.  
Also you need to %ll in the addresses of the devices you would like to be receiving the OSC messages  
being sent out by the Art SSC. In these IP Out %elds you enter both IP address and port number; in the  
following syntax: “ipaddress:port”. E.g. to send OSC messages to your device at 192.168.1.99 and port  
number 7070, you would %ll in: “192.168.1.99:7070”.  
You can specify up to 4 addresses. Fill in “0.0.0.0:0” in each %eld you do not need to use.  
IP  
For setting up the IP address and sub-net mask of the Art SSC. The 'Router' %eld is only required when  
doing Port Forwarding.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Time-code  
The Art SSC can receive a time-code signal to trigger Actions, synchronise the Recorder or to convert to  
other time-code protocols. It supports SMPTE, MTC, OSC and Art-net time-code signals, however, only  
one protocol can be selected at a time. It is also possible to select 'Internal' as the time-code source; in  
this case the internal timing logic of the Art SSC is used. Please see the following diagram.  
By enabling the time-code outputs for MTC, OSC or Art-Net you create a time-code converter, or when  
'Internal' is selected as input source, a time-code master.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Art IO Web-Interface  
The Art IO Web-Interface has the following pages.  
Home  
This page o>ers a status overview of all main properties and shows the values of the GPI and GPO ports.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Show Control  
The Show Control page is very similar to the Show Control page in the Art SSC. Please refer to page 21  
for a detailed description. Please note that some sources are only available in the Art SSC and not in the  
Art IO (e.g. Scheduler, Timecode, Recorder).  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Show Control page is prepared with templates of operations that are very typical usage of the Art  
IO. The following tables describes those templates.  
Art-Net DMX  
DMX Art-Net  
DMX Outputs  
Converts incoming Art-Net to DMX. The DMX port needs to be set to output.  
Converts incoming DMX to Art-Net. The DMX port needs to be set to input.  
Control the relays by DMX channel 1 through 8. Values below 50% switch the relay o>,  
values above 50% will swich it on. The DMX port needs to be set to input.  
Art-Net Outputs  
Inputs DMX  
Control the GPOs by incoming Art-Net channel 1 through 8. Values below 50% switch the  
relay o>, values above 50% will swich it on. The DMX port needs to be set to input.  
Convert the state of the GPI to DMX channels 1 through 8. When a GPI is to digital the DMX  
channel will switch between value 0 and 255, when set to analogue the channel will range  
between 0 and 255. The DMX port needs to be set to output.  
Inputs Art-Net  
Convert the state of the GPI to Art-Net channels 1 through 8. When a GPI is to digital the  
Art-Net channel will switch between value 0 and 255, when set to analogue the channel  
will range between 0 and 255.  
Inputs OSC  
Convert the state of the GPI to OSC. The OSC URI is /gpiX, where X is the GPI port number.  
OSC Outputs  
Control the GPOs by incoming OSC messages. The OSC URI is /gpoX, where X is the GPO  
port number.  
Demo  
This demonstrates the capability of the Art IO by connecting the GPI's and GPO's to  
various protocols like DMX, OSC and eTouch.  
Production Test  
This template is used for testing the device during the production process.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Monitors  
This page allows you to inspect the incoming and outgoing data.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Settings  
This page contains all the user settings.  
General  
You can change the Art IO's label. This label can be used to distinguish the unit in a set-up with multiple  
devices.  
The 'Blink' check-box will Tash the device's LED to help to identify it amongst multiple devices.  
DMX Port  
Choose here to use the DMX port either as input or as output.  
Art-Net  
The Art-Net feature in the Art IO supports 1 universes out and 1 universes in. You can map each of those  
universes to any of the 256 available universes in the Art-Net protocol. This number is zero-based,  
ranging from 0 up to and including 255.  
The broadcast messages sent out by Art-Net do put a certain load on the network, therefore it is  
recommended to disable Art-Net when not in use.  
Art-Net transmission can be switched on or o> by the 'Enabled' check-box.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GPI  
The GPI section signals measured by the input ports. It allows you to switch a port between Digital and  
Analog. When set to Analog you need to calibrate the input range so the Art IO knows the minimal and  
maximum voltage it can receive on that port. The Art IO supports any voltage inside the range of 0V and  
10V.  
Follow these steps to calibrate a port:  
1. enable the 'Calibrate' button  
2. apply the minimal voltage  
3. apply the maximum voltage  
4. disable the 'Calibrate' button  
Caution: Applying a voltage >10V could damage the Art IO.  
GPO  
This section shows you the status of each relay and allows you to manually change it.  
RS-232  
This section gives you control of the RS-232 properties. Make sure these settings match the device you  
are communicating with.  
UDP  
In this section you can set the port number on which the Art SSC will listen out for UDP messages. The  
IP addresses and port numbers for outgoing UDP messages are set in the tasks at the Show Control  
page.  
OSC  
Set the port number on which the Art SSC will listen for OSC messages in this section.  
Also you need to %ll in the addresses of the devices you would like to be receiving the OSC messages  
being sent out by the Art SSC. In these IP Out %elds you enter both IP address and port number; in the  
following syntax: “ipaddress:port”. E.g. to send OSC messages to your device at 192.168.1.99 and port  
number 7070, you would %ll in: “192.168.1.99:7070”.  
You can specify up to 4 addresses. Fill in “0.0.0.0:0” in each %eld you do not need to use.  
IP  
For setting up the IP address and sub-net mask of the Art SSC. The 'Router' %eld is only required when  
doing Port Forwarding.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alphabetical Index  
Action.............................................23  
Action-list........................................23  
Actions...........................................23  
Art-Net............................................. 9  
astronomical clock............................28  
Calibrate.........................................36  
Capture..........................................15  
CLI.................................................15  
command line interface.....................15  
compression....................................18  
Console...........................................14  
Conversion......................................22  
Cue................................................14  
Date............................................... 28  
daylight saving time.........................29  
DC................................................... 4  
DIN Rail............................................4  
DMX-512..........................................9  
Don't Care.......................................25  
EDIT mode......................................14  
eManager..........................................7  
eTouch.......................................11, 22  
fade time........................................15  
firmware updates...............................7  
Flank..............................................23  
GMT...............................................29  
GPI................................................10  
GPO...............................................12  
Groups............................................17  
Highest Takes Precedence..................19  
hold time........................................15  
Home.............................................13  
HTP................................................ 19  
IP address.........................................5  
iPhone............................................10  
Kensington........................................4  
latitude........................................... 28  
link.................................................16  
Location..........................................28  
lock..................................................4  
longitude.........................................28  
Loop...............................................20  
memories........................................18  
MIDI...............................................12  
Monitors..........................................26  
MTC................................................12  
OSC...............................................10  
Output Routing................................28  
PLAY...............................................14  
Playback.........................................19  
Port Forwarding................................29  
Power...............................................4  
Real-Time Clock..........................25, 28  
Recorder.........................................18  
refresh rate.....................................18  
reset................................................6  
RJ-45.............................................10  
Routing...........................................20  
RS-232...........................................12  
RTC................................................ 28  
Run Mode........................................14  
Scheduling......................................25  
Settings..........................................27  
Show Control...................................21  
SMPTE............................................11  
sub-net mask....................................5  
sunrise...........................................28  
sunset............................................28  
Tasks..............................................24  
Templates.......................................22  
Time...............................................28  
Time-code.......................................19  
time-zone........................................29  
TouchOSC.......................................10  
Trigger............................................24  
trigger channel................................19  
UDP................................................10  
Unit................................................14  
UTC................................................29  
web-interface..................................13  
Weekday.........................................25  
XLR..................................................9  
............................................... 21, 27  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Chipper CH500H74500 User Manual
Fisher Price Baby Toy G2974 User Manual
Fluke Thermometer Food Safety Thermometer User Manual
Ford Automobile F 350 User Manual
Freedom9 Switch IP 800 User Manual
Frigidaire Washer MLXG42RE User Manual
Gardena Water Pump 13000 SP User Manual
GBC Binding Machine TL300 User Manual
GE Hot Beverage Maker 106810 User Manual
Glen Dimplex Home Appliances Ltd Ventilation Hood CHIM101 User Manual