GE Monogram Ventilation Hood ZXR7510 User Manual

Installation  
Instructions  
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com  
ZXR758 and ZXR7510  
Recirculating Accessories  
For Model ZV750, Vent Hood  
M
o
no  
g
ra  
m
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Preparation  
REQUIRED ACCESSORIES  
• Order the required accessory at the same time as the  
vent hood and have on site before installation.  
• Each kit includes decorative duct cover, air deflector  
and charcoal filters.  
This book provides step by step instructions to install the  
Monogram ZV750 wall mounted hood for recirculating  
operation.  
• One of the following accessory kits is required for  
non-vented wall mounted installations of model ZV750.  
Choose the correct kit according to ceiling heights:  
ZXR758 – For 8 to 9 ft. ceiling height.  
ZXR7510 – For 9 to 10 ft. ceiling height.  
PRODUCT DIMENSIONS  
The vent hood must be installed 24" min. and 30" max.  
above the cooking surface. 25-1/2" is recommended for  
best performance and to insure that the duct cover  
meets the ceiling. The cooking surface should be at least  
36” above the floor. Installation will be easier if the vent  
hood is installed before the cooktop and countertop is  
installed.  
*Height  
to Ceiling  
8-1/4"  
34-5/8"  
21-5/8"  
* ZXR758  
26-1/4" for 8 ft. Ceiling  
38-1/4" for 9 ft. Ceiling  
ZXR7510  
34-1/4" to 50-1/4" for  
*25-1/2" Recommended  
9 ft. to 10 ft. Ceiling  
* The distance between the cooking surface and the bottom of the  
hood must be at least 24” and up to 30” The 25-1/2” recommended  
installation height, above the standard 36” countertop, will insure  
duct cover fit to the ceiling.  
36" Min.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Preparation  
POWER SUPPLY  
DUCT COVER ACCESSORIES  
A duct cover accessory is required for recirculating  
operation. Use this chart to determine which  
accessory is required for your ceiling height.  
IMPORTANT  
– (Please read carefully)  
WARNING:  
ZV750SY Installation Heights  
Actual  
FOR PERSONAL SAFETY, THIS APPLIANCE MUST  
BE PROPERLY GROUNDED.  
* Possible Hood  
Installation Height  
Ceiling  
Height  
Recirculating  
Accessory  
Remove house fuse or open circuit breaker before  
beginning installation.  
24-1/2  
711″  
80″  
81″  
82″  
83″  
84″  
85″  
86″  
87″  
88″  
89″  
810″  
811″  
90″  
91″  
92″  
93″  
94″  
95″  
96″  
97″  
98″  
99″  
910″  
911″  
100″  
25-1/2″  
Do not use an extension cord or adapter plug with  
this appliance. Follow National Electrical Code or  
prevailing local codes and ordinances.  
25-1/2to 26-1/2″  
25-1/2to 27-1/2″  
25-1/2to 28-1/2″  
25-1/2to 29-1/2″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
25-1/2to 30″  
Electrical supply  
This vent hood must be supplied with 120V, 60Hz,  
and connected to an individual, properly grounded  
branch circuit, and protected by a 15 or 20 amp  
circuit breaker or time delay fuse.  
• Wiring must be 2 wire with ground.  
• If the electrical supply does not meet the above  
requirements, call a licensed electrician before  
proceeding.  
• Route house wiring as close to the installation  
location as possible. Wiring should enter at least 4"  
above the bracket on the right side.  
• Connect the wiring to the house wiring in  
accordance with local codes.  
Grounding instructions  
The grounding conductor must be connected to  
a ground metal, permanent wiring system, or an  
equipment-grounding terminal or lead on the hood.  
WARNING:  
The improper connection  
of the equipment-grounding conductor can result  
in a risk of electric shock. Check with a qualified  
electrician or service representative if you are in  
doubt whether the appliance is properly grounded.  
* Based on 36countertop height.  
ZV750SY Duct Cover Dimensions  
9-1/4"  
Hood and  
Accessory  
TOOLS AND MATERIALS  
REQUIRED (NOT SUPPLIED)  
B
A
B
22-13/16″  
34-5/8″  
ZXR758C  
18-7/8″  
18-7/8″  
• 10 mm Hex wrench/socket  
• Safety glasses  
• Tape measure  
• Knife  
ZXR7510C  
A
• Duct tape  
• Spirit level  
• Gloves to protect against sharp  
edges  
• 120V 60Hz. 15 or 20 Amp, 2 wire  
with ground. Properly grounded  
branch circuit.  
• Strain relief for junction cover.  
• 6" round duct, length to suit  
installation.  
• Wire cutter/stripper  
• Wire nuts  
• Electric drill and  
appropriate bits  
• Phillips and flat blade  
screwdrivers  
• Hammer  
11-7/8"  
• Pliers  
• Center punch  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Preparation  
• Locate and remove 2 screws at the top of the  
REMOVE THE PACKAGING  
assembly and 2 screws inside the hood behind the  
filter guides on the left and right sides. Discard the  
shipping board.  
The vent hood is shipped secured to a shipping  
board with 4 screws.  
• Remove the duct cover, parts box and styrofoam  
packaging.  
• Lift the hood out of the box, using hand grips on  
both sides of the shipping board.  
Junction  
Box  
• Remove and properly discard the plastic wrapping.  
Knockout  
Mounting  
Screw  
Mounting  
Screw  
Shipping Board  
• Remove junction box cover.  
• Remove knockout from junction box.  
• Install strain relief onto junction box.  
Mounting Screw  
Shipping Board  
Check Installation Hardware  
Locate the hardware accessory box packed with the  
hood and check contents.  
Drill 1/8" Pilot Holes For Mounting Brackets.  
C
L
5-7/8"  
26-14" to  
38-1/4" to  
8
9
ft. Ceiling  
ft. Ceiling  
3 Stainless  
Steel Grease  
Filters  
38-1/4" to 50-1/4" For  
9ft. to 10 ft. Ceiling  
Using Optional Accessory  
ZX10SY Duct Cover  
C
L
17-5/16"  
C
L
Drill 1/8" Pilot Holes.  
Drill 1/8" Pilot Holes.  
Align edge 25-1/2" above Cooking Surface.  
Wall Mount Template  
10 Wood  
Screws  
10 Metal Wall  
2 Mounting Brackets  
Fasteners  
Check contents of the required accessory,  
ZXR758 or ZXR7510.  
2 Large  
Flat Washers  
2 Wood  
Screws  
Decorative  
Duct  
Covers  
2 Plastic  
Wall Fasteners  
Air Deflector with  
Upper Duct  
Connector  
Duct Cover Bracket  
(not required for  
recirculating operation)  
2 Phillips Head  
Decorative Screws  
2 Phillips Head  
Decorative Screws  
Recirculating  
Decorative  
Duct Cover  
3 Charcoal Filters  
2 Side Bars with 4 Machine Screws  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
1 DETERMINE INSTALLATION  
LOCATION  
To determine the exact location of the vent hood.  
• Locate the template packed with the literature.  
– Measure 36" from the floor to the top of the  
cooking surface. Add 25-1/2" recommended  
space from the cooking surface to the bottom  
of hood. Mark that location.  
– Use a level to draw a straight pencil line on the  
wall.  
– Tape the template in position along the penciled  
line. CHECK TO BE SURE THE TEMPLATE IS  
LEVEL.  
2 INSTALL MOUNTING BRACKETS  
Whenever possible, the vent hood should be secured to wall  
studs.  
• With the template taped in place, use a punch to  
mark all mounting screw locations.  
• Drill 1/8" pilot holes at the 6 punched locations.  
• Remove the template.  
• Enlarge holes that did not enter studs to 3/8" and  
tap anchors for metal wall fasteners into the holes.  
– Drive screws into the fasteners to allow anchors to  
expand against the wall material. Remove the  
screws for final installation.  
• Secure the mounting brackets to the wall studs with  
wood screws provided.  
– For hollow walls, secure the mounting brackets  
through the anchors.  
– Measure from the peak of the hood to the ceiling  
as indicated.  
Ceiling  
Screws  
“B”  
Note: Screws Aand  
Screws  
“A”  
Bare pre-assembled  
onto the brackets. Do  
not remove these  
screws.  
Drill 1/8" Pilot Holes For Mounting Brackets.  
5-7/8"  
26-14" to  
38-1/4" to  
8
9
ft. Ceiling  
ft. Ceiling  
38-1/4" to 50-1/4" For  
9ft. to 10 ft. Ceiling  
Using Optional Accessory  
ZX10SY Duct Cover  
17-5/16"  
C
L
Drill 1/8" Pilot Holes.  
Drill 1/8" Pilot Holes.  
Align edge 25-1/2" above Cooking Surface.  
For ZXR758 –  
26-1/4" to 38-1/2" for 8 ft. to 9 ft. ceilings.  
For ZXR7510 –  
38-1/4" to 50-1/4" for 9 ft. to 10 ft. ceilings.  
• Use a level to draw a line straight up, from the  
centerline on the template to the ceiling.  
House Wiring Locations  
• The junction box is located on the top of the  
hood, at the front right side.  
• Route house wiring as close to the installation  
location as possible; through the ceiling, soffit or  
back wall. Wiring should enter at least 4" above  
the bracket on the right side.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
3 INSTALL THE HOOD  
Place the hood on the brackets and slide left to right  
to align with rectangular slots at the top.  
Screws B”  
To Secure Hood  
To Wall  
Lower  
Mounting Screws  
• Align the hood lower mounting holes with pilot  
holes in the wall.  
• Using two large flat washers (supplied), install wood  
screws or wall fastener screws, loosely, into lower  
mounting holes. Do not tighten.  
• Level the hood by tightening or loosening the  
screws “A” located on the bottom mounting  
brackets.  
Level and  
Height  
Adjustment  
Screws A”  
• Tighten lower mounting screws.  
• Tighten screws “B” located at the top of the  
mounting bracket against the hood to clamp  
the position. Do not overtighten screws.  
• Adjust the installation height by tightening or  
loosening the screws “A” at the bottom of the  
brackets.  
5 INSTALL AIR DEFLECTOR  
ASSEMBLY  
• Place the assembly over the hood outlet.  
• Hold the assembly against the ceiling. The penciled  
centerline should show through the slot on the  
deflector. Mark the two screw holes on the back of  
the assembly.  
• Remove the  
assembly and  
drill 1/8" pilot  
holes into  
4 SIZE DUCT PIECE  
• Hold upper air deflector with duct connector  
against the ceiling.  
• Measure from the  
bottom of the support  
to top of the hood  
as shown. Reduce  
this dimension  
by 1" to facilitate  
installation. The  
duct will cover/  
overlap the deflector  
Duct  
Length  
Measure  
Length  
the wall studs.  
• Enlarge holes  
and the hood outlets.  
that did not enter  
studs to 3/8" and  
tap plastic or metal  
anchors into the  
holes, flush with  
the wall.  
• Mount the assembly  
onto the hood outlet,  
push up against the ceiling  
and install the screws provided.  
• Use duct tape to seal the connection.  
• Cut duct piece to  
size and slip onto the  
bottom of the duct  
connector.  
• Use duct tape to  
secure duct piece  
to connector.  
CAUTION:  
Do not use sheet metal screws  
on the bottom duct flange.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
6 CONNECT ELECTRICAL  
7 INSTALL DUCT COVERS AND  
UTILITY BARS  
• Verify that power is turned off at the source.  
• Separate the duct covers supplied with the hood.  
• Discard the upper (inner) section.  
WARNING:  
If house wiring is not 2-wire  
• Insert the ZXR758 or ZXR7510 duct cover (with  
vent holes) into the original lower section. Be sure  
that the new duct section is inside the shorter  
original section.  
with a ground wire, a ground must be provided by  
the installer. When house wiring is aluminum, be  
sure to use U.L. approved anti-oxidant compound  
and aluminum-to-copper connectors.  
Mounting Screw Holes  
• Insert house wiring through strain relief and  
tighten.  
• Connect white leads to branch circuit white lead.  
• Connect black leads to branch circuit black lead.  
• Connect green/yellow leads to branch circuit green  
lead or bare ground lead.  
• Secure all connections with wire nuts on each  
electrical connector.  
• Push wires into junction box and replace cover.  
Be sure wires are not pinched.  
• Place the decorative duct covers on top of the hood.  
• Insert the lower portion of the duct cover into the  
impressions on the top of the hood.  
• Extend the inner duct upwards to meet the ceiling  
and support frame.  
• Secure the duct cover to the frame with the 2 small  
Phillips screws provided.  
• Install the side utility bars as shown with screws  
provided.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
8 INSTALL FILTERS  
9 FINALIZE INSTALLATION  
• Remove the protective film covering the control  
panel on the front face of the hood, and any other  
packaging materials.  
Upper Charcoal  
Filter Slots  
• Refer to the Owner’s Manual for operating  
instructions.  
Lower Grease  
Filter Slots  
• There are two slots inside the back and front of the  
hood. These slots will hold the charcoal filters and  
stainless steel grease filters in place.  
Install Charcoal Filters  
Upper Charcoal  
Filter Slots  
Grasp Tab,  
Lift and Pull Forward  
• Remove protective film on charcoal filters.  
• Tip charcoal filters into the upper (top) slots at the  
rear of the opening. Grasp the filter tab, lift and  
pull forward until it rests in the front slots.  
• Install all 3 charcoal filters.  
Install Grease Filters  
Lower  
Filter Slots  
• Remove protective film from grease filters.  
• Tip the grease filter into the lower slots at the rear  
of the opening. Lift the filter and pull the knob  
forward until the filter rests on the slots.  
• Install all 3 grease filters.  
• To remove the filters, grasp the knob, push the  
filter toward the rear and tilt downward. Grasp tabs  
on charcoal filters, push toward the rear and tilt  
downward.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: While performing installations described in this book,  
safety glasses or goggles should be worn.  
TM  
For Monogram local service in your area, call  
1.800.444.1845.  
Note: Product improvement is a continuing endeavor at  
General Electric. Therefore, materials, appearance and  
specifications are subject to change without notice.  
Pub. No. 49-80046-1  
04/07 JR  
GE Consumer & Industrial  
GE Appliances  
General Electric Company  
Louisville, KY 40225  
Printed in Italy  
monogram.com  
©2007 GE Company  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Compaq Network Card NAS B3000 User Manual
Craftsman Air Compressor 91916644 User Manual
Crown Audio Portable Speaker C 8 User Manual
Cub Cadet Lawn Mower 190 670 100 190 678 100 User Manual
Dymo Printer 18949 User Manual
Dynacord Stereo Amplifier DSA 8204 User Manual
Dynex Paper Shredder DX PS06CC User Manual
Elation Professional Landscape Lighting Zoom 575E User Manual
Electro Voice Car Speaker sb121a 110v User Manual
Field Controls Range Oil Venting Systems User Manual