Fujitsu Barcode Reader Primergy N800 User Manual

®
PRIMERGY N800 Datacenter Server  
System Configuration Guide (Ver.2) (Jul / 2001)  
2
8
9
PRIMERGY N800  
Configuration of Clustering  
Rackmount  
Index  
The numbers on the left hand side of each  
page correspond to the various options  
available with PRIMERGY as follows  
1
2
3
4
5
6
7
8
9
CPU slot  
RAM module slot  
3.5 inch HDD Bay  
5 inch Bay  
RS-232C  
PCI slot  
ISA slot  
Redundant PSU  
Others  
Key to  
Or  
And  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Install Operating System  
- Boot disk can be an external disk. In this case, the disk must be connected to PG-142B RAID Controller.  
- Basically, installation should be done by "Installation and Startup Service". So please contact with your local sales representative.  
Mounting devices  
- In N800, there are four internal HDD bays (2bays/1ch x 2)  
- N800 has one internal 5" bay in chassis for DDS4 (In case of SCSI connection, the DDS4 is available for  
daisy-chain connection with HDD)  
- PRIMERGY S10 (Backup Cabinet) is available if " more then two backup devices" or "backup devices except for DDS4"  
are installed.  
Configuration Chart  
N800  
PRIMERGY S10  
(PGUR1BC3)  
Onboard SCSI Controller  
(Ultra2 Wide x 2)  
ChB  
ChA  
or  
PRIMERGY S10  
(PGUR1BC3)  
DDS4  
(Option)  
SCSI Controller  
(PG-126)  
Ch0  
Ch1  
RAID Controller (Standard)  
(Ultra160 x 2)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Connection Matrix  
For Internal HDD/PRIMERGYS30  
Channel 0  
Standard  
RAID Controller  
For Internal HDD/PRIMERGYS30  
Channel 1  
PRIMERGY N800  
Connection of internal HDD and internal backup devices  
For Internal Backup device/Internal HDD  
Onboard  
SCSI  
Ultra2 Wide A  
Ultra2 Wide B  
For PRIMERGY S10/Internal HDD  
Internal HDD  
Backup device  
One device is connected  
Connection Pattern  
Host  
Two devices are connected  
Wide Narrow device  
Configuration SCSI  
Interface  
Cable  
Internal HDD  
In case that  
DDS4 is  
Except for Narrow  
DDS4  
device x 2 device x 2 and  
Wide device  
connected  
Up to four HDDs can be  
Onboard SCSI (Ultra2 Wide Bch)  
PRIMERGY S10 (PGUR1BC3)  
SCSI Cable (PG-CBLS007/008/009)  
or  
Array  
Standard  
Cable(X2) installed  
Onboard SCSI  
(Ach)  
Configuration Ultra160  
RAID Controller (Ch0/1) (Standard 1) 9GB, 10,000rpm  
equipment) 2) 18GB, 10,000rpm  
3) 18GB, 15,000rpm  
SCSI Controller (PG-126)  
PRIMERGY S10 (PGUR1BC3)  
SCSI Cable (PG-CBLS001/002/003)  
4) 36GB, 10,000rpm  
- In case of SCSI configuration (Up to four HDDs can be mounted), internal DDS4 can be connected to ChA of Onboard SCSI by daisy chain.  
- when connecting RAID Controller with PRIMERGY S30, or SCSI Controller with Internal HDD, both SCSI Channel of Onboard SCSI Controller must be connected  
to Internal HDD.  
Mountable I/O options  
N800  
Maximum  
number  
Cards  
Product ID  
Bus  
of cards Total  
REMARKS  
mounted  
10  
SCSI Controller  
(Ultra Wide Diff)  
SCSI Controller  
(Ultra2 Wide LVD)  
PG-123  
PCI64  
PCI64  
PCI64  
PCI64  
PCI64  
4
2
4
1
4
4
5
4
For external disk array  
PG-126  
Fibre Channel Controller PG-FC102  
RAID Controller  
(Ultra160 LVD)  
RAID Controller  
(Ultra160 LVD)  
Standard  
Mounted in PCI slot1  
Equipment  
PG-142B/C  
EthernetController  
(1000Base-SX)  
EthernetController  
(100Base-TX)  
PG-188  
PCI64  
PCI64  
PCI64  
2
1
2
Standard  
Equipment  
PG-185  
Mounted in PCI slot3  
EthernetController  
(100Base-TX)  
For Remote Management  
Remote Service Board  
PGURSB101  
PCI64  
1
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration  
Connection Table  
PGTN8BHRD2  
PGTN8BGRD2  
Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(2MB), Memory:1GB(ECC), HDD:Option  
Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(1MB), Memory:1GB(ECC), HDD:Option  
Rackmount Type  
<Items>  
CPU Field Upgrade :  
Memory addition :  
Go to A  
Go to B  
Go to C  
Go to D  
Go to E  
Go to F  
Go to G  
Standard Memory Conversion :  
Internal Hard Disk Drive connection  
External Hard Disk Drive connection  
Backup devices  
Others (NIC etc.)  
CPU  
Max : 8CPUs  
CPU Field Upgrade Kit - 74 (Pentium III Xeon 700MHz (2MB) x1)  
1
A:  
GP5-FG20HT/GP5BFG20HT  
Standard : 2CPUs  
CPU Field Upgrade Kit - 73 (Pentium III Xeon700MHz (1MB) x1)  
GP5-FG20GT/GP5BFG20GT  
Memory  
Standard memory : 1GB (256MB-DIMMx4)  
Max. memory: 32GB  
Additional Memory - 512MB (256MB-DIMMx2)  
GP5-RM51J/GP5BRM51J  
B:  
2
2
Additional Memory - 1GB (512MB-DIMMx2)  
GP5-RM1J/GP5BRM1J  
Additional Memory Board  
PG-RB103/PGBRB103  
Additional Memory - 2GB (1GB-DIMMx2)  
GP5-RM2J/GP5BRM2J  
Standard Memory Conversion  
C:  
Standard Memory Conversion Kit-2GB (512MB SDRAM-DIMMx4)  
2
PGBRU2C  
Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)  
PGBRU4C  
Internal Hard Disk  
Max : 4  
Hard Disk - 9GB (Ultra160 10,000rpm)  
(Hot Plug)  
D:  
6
Standard RAID Controller  
PG-HDH91B/PGBHDH91B  
(Ultra160/2ch/64MB cache)  
Hard Disk - 18GB (Ultra160 10,000rpm)  
(Hot Plug)  
PG-HDH81B/PGBHDH81B  
Standard RAID Controller Conversion Kit  
(Standard RAID to PG-142C)  
(Ultra160/2ch/64MB Cache/BBU)  
PGB1U42C1  
Hard Disk - 18GB (Ultra160 15,000rpm)  
(Hot Plug)  
PG-HDH85B/PGBHDH85B  
Hard Disk - 36GB (Ultra160 10,000rpm)  
(Hot Plug)  
PG-HDH61B/PGBHDH61B  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration  
External Hard Disk  
Max:13  
Hard Disk - 9GB (Ultra160 7,200rpm)  
(Hot Plug)  
E:  
6
RAID Controller  
Ultra160/2ch  
PG-HDH97B/PGBHDH97B  
SCSI Cable (2m)  
PRIMERGY S30  
PGUR1DC6  
64MB Cache  
PG-CBLS004  
Hard Disk - 18GB (Ultra160 72,00rpm)  
(Hot Plug)  
PG-142B/PGB142B  
PG-HDH87B/PGBHDH87B  
RAID Controller  
Ultra160/2ch  
SCSI Cable (5m)  
PG-CBLS005  
Hard Disk - 9GB (Ultra160 10,000rpm)  
(Hot Plug)  
64MB Cache/BBU  
PG-142C/PGB142C  
PG-HDH91B/PGBHDH91B  
Hard Disk - 18GB (Ultra160 10,000rpm)  
(Hot Plug)  
SCSI Cable (10m)  
PG-CBLS006  
PG-HDH81B/PGBHDH81B  
Hard Disk - 18GB (Ultra160 15,000rpm)  
(Hot Plug)  
PG-HDH85B/PGBHDH85B  
Hard Disk - 36GB (Ultra160 10,000rpm)  
(Hot Plug)  
PG-HDH61B/PGBHDH61B  
Power Supply Module  
Max:1  
PGUPU103/PGBUPU103  
Backup Devices  
Up to four Tape units can be mounted  
Onboard SCSI Controller  
Tape Drive DLT8000  
F:  
PRIMERGY S10  
PGUR1BC3  
PG-DL401/PGBDL401  
4
Two 5" bays are occupied  
SCSI Cable (1.8m)  
PG-CBLS007  
Tape Drive DLT7000  
PG-DL351/PGBDL351  
Two 5" bays are occupied  
SCSI Cable (5m)  
PG-CBLS008  
Tape Drive DLT4000  
PG-DL201/PGBDL201  
Two 5" bays are occupied  
Tape Drive LTO  
SCSI Cable (10m)  
PG-CBLS009  
PG-LT101/PGBLT101  
Tape Drive SLR100  
PG-SL101/PGBSL101  
6
SCSI Controller U2W  
PG-126/PGB126  
SCSI Cable(1.5m)  
PG-CBLS001  
Tape Drive SLR60  
PG-SL601/PGBSL601  
SCSI Cable (5m)  
PG-CBLS002  
Tape Drive SLR50  
PG-ML301/PGBML301  
Tape Drive DAT DDS4  
PG-DT401/PGBDT401  
SCSI Cable (10m)  
PG-CBLS003  
Tape Drive DAT DDS3  
PG-DT301/PGBDT301  
Tape Drive DAT DDS4 Autoloader  
PG-DTA102/PGBDTA102  
Two 5" bays are occupied  
Tape Drive DAT DDS3 Autoloader  
PG-DTA101/PGBDTA101  
Two 5" bays are occupied  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration  
Onboard SCSI Controller  
Tape Drive DAT DDS4  
PG-DT401/PGBDT401  
4
Only one DDS4 can be mounted in 5"bay  
Others  
Gigabit Ethernet Controller (1000Base-SX))  
PG-188/PGB188  
6
6
6
6
G:  
Fast Ethernet Controller (100Base-TX)  
PG-185/PGB185  
Fibre Channel Controller  
PG-FC102  
Remote Service Board  
PGURSB101  
Remote Service Board Kit B  
PG-RSBOP2  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration  
Configuration of Microsoft® Clustering  
<PRIMERGY N800 - FUJITSU GR720>  
Fibre Channel Controller  
PG-FC102  
Fibre Channel Cable  
6
6
6
GP5-311 (2m)/312(5m)/313(15m)  
Fibre Channel Controller Fibre Channel Cable  
PG-FC102 GP5-311 (2m)/312(5m)/313(15m)  
Disk Array  
FUJITSU  
GR720  
Ethernet Controller  
Controller of  
Disk Array  
(Primary)  
PG-185/PGB185  
Fast Ethernet Cable  
DCL-FEA05U  
Ethernet Controller  
PG-185/PGB185  
6
6
6
Controller of  
Disk Array  
(Secondary)  
Fibre Channel Controller Fibre Channel Cable  
PG-FC102 GP5-311 (2m)/312(5m)/313(15m)  
Fibre Channel Controller  
PG-FC102  
Fibre Channel Cable  
GP5-311 (2m)/312(5m)/313(15m)  
<PRIMERGY N800 - EMC® Clariion®/Symmetrix®>  
Disk Array  
6
6
6
FC Host Bus Adapter  
FC Host Bus Adapter  
Fibre Channel Cable  
EMC®  
Clariion® FC5300  
Clariion® FC4500  
Symmetrix®8000  
Fibre Channel Cable  
Ethernet Controller  
Controller of  
Disk Array  
(Primary)  
PG-185/PGB185  
Fast Ethernet Cable  
DCL-FEA05U  
Ethernet Controller  
PG-185/PGB185  
6
6
6
Controller of  
Disk Array  
(Secondary)  
FC Host Bus Adapter  
Fibre Channel Cable  
FC Host Bus Adapter  
Fibre Channel Cable  
Please contact your local FUJITSU sales representative in the case as follows;  
- In case of connecting with EMC disk array, each component surrounded by  
"Fibre Channel Cable", "Fibre Channel HUB") should be EMC's.  
- As for the certified configuration of Windows2000 Datacenter Server.  
- Four nodes Clustering.  
("Fibre Channel Adapter with driver SW",  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration  
Rackmount  
Rack and Rack Options  
40U Rack  
GP5-R1RC6  
40U Rack & Rack Coupling Kit  
GP5-R1RC7  
36U Rack  
36U Rack & Rack Coupling Kit  
PG-R3RC1  
PG-R3RC2  
CPU or DISK node  
24U Rack  
GP5-R2RC3  
24U Rack & Rack Coupling Kit  
GP5-R2RC4  
24U Rack  
PG-R4RC1  
24U Rack & Rack Coupling Kit  
PG-R4RC2  
Quake Proof Stabilizer: PG-R3ST1(For PG-R3RCx/PG-R4RCx)  
Quake Proof Stabilizer: PG-R1ST1(For GP5-R1RCx/GP5-R2RCx)  
Component Shelf  
GP5-R1TB7  
Keyboard/Monitor Shelf Kit  
GP5-R1TB6  
(Up to 8 servers connection)  
Keyboard/Monitor Cable  
GP5-418(5.0m)  
Keyboard/Monitor Enhanced Switch  
GP5-SB102  
Flat Display  
GP5UR1DP11  
Keyboard/Monitor Cable  
GP5-414(1.8m)  
(Up to 4 servers connection)  
Keyboard/Monitor Cable  
GP5-411 (3.0m)  
Keyboard/Monitor Enhanced Switch  
GP5-SB101  
Enhanced Keyboard  
GP5-R1KB2  
Up to eight servers can be connected to one GP5-SB102, and up to  
64 servers can be connected with nine GP5-SB102 in cascade connection  
(Keyboard Monitor Cable: GP5-414 is required)  
* In case of Cascade connection, AC adapter is required.  
GP5-SB102  
GP5-SB102  
GP5-414  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware  
Hardware List  
Product  
Product ID  
Remarks  
CPU Field Upgrade Kit-74  
CPU Field Upgrade Kit-73  
Additional Memory 2GB  
Additional Memory 1GB  
Additional Memory 512MB  
GP5-FG20HT  
GP5BFG20HT  
[CTO option]  
GP5-FG20GT  
GP5BFG20GT  
[CTO option]  
GP5-RM2J  
Pentiumlll Xeon(700MHz)/32KB+2MBcachex1,Placed on motherboard  
Includes one CPU  
Pentiumlll Xeon(700MHz)/32KB+1MBcachex1,Placed on motherboard  
Includes one CPU  
SDRAM-DIMM (100MHz) 1024MBx2 (Buffered CL/2)  
SDRAM-DIMM (100MHz) 512MBx2 (Buffered CL/2)  
SDRAM-DIMM (100MHz) 256MBx2 (Buffered CL/2)  
GP5BRM2J  
[CTO option]  
GP5-RM1J  
GP5BRM1J  
[CTO option]  
GP5-RM51J  
GP5BRM51J  
[CTO option]  
PGBRU4C  
Standard Memory conversion 1GB to 4GB  
Standard Memory Conversion Kit-4GB  
Standard Memory Conversion Kit-2GB  
Additional Memory Board  
[CTO option]  
PGBRU2C  
Standard Memory conversion 1GB to 2GB  
[CTO option]  
PG-RB103  
Additional memory board for mounting more than 16 DIMMs  
PGBRB103  
[CTO option]  
PG-HDH61B  
PGBHDH61B  
[CTO option]  
PG-HDH85B  
PGBHDH85B  
[CTO option]  
PG-HDH81B  
PGBHDH81B  
Hard Disk Drive-36GB  
Hard Disk Drive-18GB  
Hard Disk Drive-18GB  
Hard Disk Drive-9GB  
36.4GB Ultra160 Hotplug HDD <10000rpm> 1"height  
<N800, N400 and S30>  
18.2GB Ultra160 Hotplug HDD <15000rpm>1"height  
<N800, N400 and S30>  
18.2GB Ultra160 Hotplug HDD <10000rpm>1"height  
<N800, N400 and S30>  
available with PRIMERGY as follows  
9.1GB Ultra160 Hotplug HDD <10000rpm> 1"height  
<N800, N400 and S30>  
PG-HDH91B  
PGBHDH91B  
[CTO option]  
PGUR1DC6  
PRIMERGY S30  
Rackmount(3U) Hard Disk Node Ultra160 / 14 Hotplug HDD bays  
(1"x14 HDD/2ch) / Maximum capacity is 509.6GB (36.4GB x14)  
Redundant&Hotplug FAN(Std.)/PSU(Opt.)  
(Storage Subsystem)  
1. PG-142B/PG-142C/PG-143B - PG-CBLS004/PG-CBLS005/PG-CBLS006  
2. GP5-150/1501- PG-CBLS004/PG-CBLS005/PG-CBLS006  
<Available HDD>  
PG-HDH61B/PG-HDH85B/PG-HDH81B/PG-HDH91B/PG-HDH87B/PG-HDH97B  
Only for Array configuration, CTO is available  
Tape Drive DAT DDS4  
(DAT Unit)  
PG-DT401  
Internal DAT unit (DDS-4:20GB-40GB)  
PGBDT401  
[CTO option]  
PG-DT301  
Tape Drive DAT DDS3  
(DAT Unit)  
Internal DAT unit (DDS-3:12-24GB)  
PGBDT301  
[CTO option]  
PG-DTA102  
PGBDTA102  
[CTO option]  
*1 PRIMERGY S10 is required to mount  
Tape Drive DAT DDS4 Autoloader  
(DAT Autoloader)  
Internal DAT autoloader (DDS-4: 20GB-40GB) 6cassetes  
Two 5" bays are occupied  
*1 PRIMERGY S10 is required to mount  
Tape Drive DAT DDS3 Autoloader  
(DAT Autoloader)  
PG-DTA101  
PGBDTA101  
[CTO option]  
Internal DAT autoloader (DDS-3: 12GB-24GB) 6cassetes  
Two 5" bays are occupied  
*1 PRIMERGY S10 is required to mount  
Tape Drive DLT4000  
(DLT Unit)  
PG-DL201  
PGBDL201  
[CTO option]  
PG-DL351  
PGBDL351  
[CTO option]  
Internal DLT unit (DLT4000: 20GB-40GB) Two 5" bays are occupied  
*1 PRIMERGY S10 is required to mount  
Tape Drive DLT7000  
(DLT Unit)  
Internal DLT unit(DLT7000: 35-70GB) Two 5"bays are required and occupied  
*1 PRIMERGY S10 is required to mount  
Tape Drive DLT8000  
(DLT Unit)  
PG-DL401  
PGBDL401  
[CTO option]  
Internal DLT unit(DLT8000: 40-80GB) Two 5"bays are required and occupied  
*1 PRIMERGY S10 is required to mount  
Tape Drive LTO  
(LTO Unit)  
PG-LT101  
Internal LTO unit (LTO: 100-200GB)  
PGBLT101  
[CTO option]  
*1 PRIMERGY S10 is required to mount  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware  
Hardware List  
Product  
Product ID  
Remarks  
Tape Drive SLR50  
(Tape Unit)  
PG-ML301  
PGBML301  
[CTO option]  
PG-SL601  
Internal Tape unit (SLR50: 25-50GB)  
*1 PRIMERGY S10 is required to mount  
Tape Drive SLR60  
(Tape Unit)  
Internal Tape unit (SLR60: 30-60GB)  
*1 PRIMERGY S10 is required to mount  
PGBSL601  
[CTO option]  
PG-SL101  
Tape Drive SLR100  
(Tape Unit)  
Internal Tape unit (SLR100: 50-100GB)  
*1 PRIMERGY S10 is required to mount  
PGBSL101  
[CTO option]  
PGUR1BC3  
PRIMERGY S10  
(Backup Cabinet)  
Rackmount 3U 5" bay node for N800/N400/H200  
Up to four Tape units can be mounted  
<Available Backup devices>  
Occupy two bays : PG-DL201/PG-DL351/PG-DL401/PG-DTA101/PG-DTA102  
Occupy one bay: PG-SL101/PG-SL601/PG-ML301/PG-DT401/PG-DT301  
*CTO is available  
Power Supply Module  
Power Supply Module  
40U Rack  
PGUPU103  
PGBUPU103  
[CTO option]  
PG-PU102  
Redundant PSU (500W) *Power Code is required  
<PRIMERGY S30>  
*1 S30 is available on N800/N400/MS610/H200  
Redundant PSU (500W) *Power Code is required  
<PRIMERGY N400/S10>  
PGBPU102  
[CTO option]  
GP5-R1RC6  
*1 S10 is available on N800/N400/H200  
19'' 40U Locker , Front door,rear door,side panel,earthquake proof  
board ,blank panel is attached. Size(WxDxH)mm:600x900x2000  
<Number of units required for installation>  
N800: 7U  
PGUR1DC6: 3U/PGUR1BC3: 3U  
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)  
Component shelf: 5U  
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)  
Color: Black  
40U Rack&Rack  
Coupling Kit  
GP5-R1RC7  
PG-R3RC1  
19''40U Locker + connection metal fittings Front door,rear  
door,concatenation frame,blank panel is attached.  
Color: Black  
36U Rack  
19'' 36U Locker , Front door,rear door,side panel,earthquake proof  
board ,blank panel is attached. Size(WxDxH)mm:700x950x1800  
<Number of units required for installation>  
N800: 7U  
PGUR1DC6: 3U/PGUR1BC3: 3U  
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)  
Component shelf: 5U  
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)  
Color: Black  
36U Rack&Rack  
Coupling Kit  
PG-R3RC2  
19''36U Locker + connection metal fittings Front door,rear  
door,concatenation frame,blank panel is attached.  
Color: Black  
24U Rack  
GP5-R2RC3  
19'' 24U Locker , Front door,rear door,side panel,earthquake proof  
board, blank panel is attached. Size(WxDxH)mm:700x950x1267  
<Number of units required for installation>  
N800: 7U  
PGUR1DC6: 3U/PGUR1BC3: 3U  
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)  
Component shelf: 5U  
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)  
Color: Black  
24U Rack&Rack  
Coupling Kit  
GP5-R2RC4  
19''24U Locker + connection metal fittings Front door,rear  
door,concatenation frame,blank panel is attached.  
Color: Black  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware  
Hardware List  
Product  
Product ID  
Remarks  
24U Rack  
PG-R4RC1  
19'' 24U Locker , Front door,rear door,side panel,earthquake proof  
board, blank panel is attached. Size(WxDxH)mm:600x900x1200  
<Number of units required for installation>  
N800: 7U  
PGUR1DC6: 3U/PGUR1BC3: 3U  
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)  
Component shelf: 5U  
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)  
Color: Black  
24U Rack&Rack  
Coupling Kit  
PG-R4RC2  
19''24U Locker + connection metal fittings Front door,rear  
door,concatenation frame,blank panel is attached.  
Color: Black  
Component Shelf  
GP5-R1TB7  
GP5-R1TB6  
Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D)  
Color: Black  
Keyboard/Monitor Shelf Kit  
Used to store display unit (CRT), a keyboard (KB), and a mouse on a rack.  
Color: Black  
Keyboard/Monitor  
Enhanced Switch  
Keyboard/Monitor  
Enhanced Switch  
GP5-SB101  
GP5-SB102  
Switch enables sharing of a set of CRT,keyboard,and mouse by two  
or more servers (up to four servers).  
Switch enables sharing of a set of CRT,keyboard,and mouse by two  
or more servers (up to eight servers). Shared up to 64 servers in  
cascade connection.* AC adapter is required for cascade connection  
(Procured locally)  
Keyboard/Monitor Cable  
GP5-418  
GP5-414  
GP5-411  
For connection with switch (For connection GP5-SB102) (5.0m)  
For cascade connection between GP5-SB102 (1.8m)  
CRT/KB cable for connection Server with GP5-SB101,  
CRT cablex1,KB/Mouse cablex1 is attached  
87Key keyboard for Rackmountable type  
Rackmountable LCD display with Keyboard, 2U height  
<GP5UR1DP1 + GP5-R1RK7>  
Keyboard/Monitor Cable  
Keyboard/Monitor Extension Cables  
Enhanced Keyboard  
Flat Display  
GP5-R1KB2  
GP5UR1DP11  
SCSI Controller UW  
PG-123  
Ultra Wide HVD (High Voltage Differential)/1ch/SMART HDD is not  
supported/ Up to 40MB/s of synchronous transfer support  
<Connector>  
(SCSI Card)  
PGB123  
[CTO option]  
- 68-pin connector for external SCSI  
- 68-pin connector for internal SCSI  
- 50-pin connector for internal SCSI  
<Use>  
For connection with external Disk Array  
* SCSI cable is required.  
SCSI Controller U2W  
(SCSI Card)  
PG-126  
Ultra2 Wide(LVD)/1ch/SMART HDD/Up to 80MB/s transfer speed  
<Connector>  
PGB126  
[CTO option]  
- 68-pin connector for external SCSI (Ultra2 Wide)  
- 68-pin connector for internal SCSI (Ultra2 Wide)  
- 68-pin connector for internal SCSI (Ultra Wide)  
- 50-pin connector for internal SCSI (Ultra Wide)  
<Use>  
For connection internal backup device/PRIMERGY S10  
RAID Controller, Ultra160/2ch/64MB cache/RAID level 0,1,5,6 (0+1)are supported  
For internal/external array configuration  
RAID Controller U160 2Channels  
(RAID Card)  
PG-142B  
PGB142B  
[CTO option]  
PG-142C  
RAID Controller U160 2Channels  
(RAID Card)  
RAID Controller, Ultra160/2ch/64MB cache/Battery Backup/  
RAID level 0,1,5,6(0+1) are supported  
For internal/external array configuration  
Convert Standard RAID Controller to PG-142C  
<N800>  
PGB142C  
[CTO option]  
PGB1U42C1  
[CTO option]  
Standard RAID Controller  
Conversion Kit  
External SCSI Cable [HDCI-HDCI] (1.5m)  
<Connection>  
SCSI Cable  
SCSI Cable  
SCSI Cable  
PG-CBLS001  
PG-CBLS002  
PG-CBLS003  
- SCSI Controller and S10/External SCSI devices  
External SCSI Cable [HDCI-HDCI] (5m)  
<Connection>  
- SCSI Controller and S10/External SCSI devices  
External SCSI Cable [HDCI-HDCI] (10m)  
<Connection>  
- SCSI Controller and S10/External SCSI devices  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware  
Hardware List  
Product  
Product ID  
PG-CBLS004  
PG-CBLS005  
PG-CBLS006  
PG-CBLS007  
Remarks  
SCSI Cable  
SCSI Cable  
SCSI Cable  
SCSI Cable  
External SCSI Cable [VHDCI-VHDCI] (2m)  
<Connection>  
- RAID Controller and S30  
External SCSI Cable [VHDCI-VHDCI] (5m)  
<Connection>  
- RAID Controller and S30  
External SCSI Cable [VHDCI-VHDCI] (10m)  
<Connection>  
- RAID Controller and S30  
External SCSI Cable [VHDCI-HDCI] (1.8m) <N800/400>  
<Connection>  
- N800: Onboard SCSI Controller to S10/External SCSI devices  
- N400: PGBCBLS011 to S10/External SCSI devices  
External SCSI Cable [VHDCI-HDCI] (5m) <N800/400>  
<Connection>  
SCSI Cable  
SCSI Cable  
PG-CBLS008  
PG-CBLS009  
- N800: Onboard SCSI Controller to S10/External SCSI devices  
- N400: PGBCBLS011 to S10/External SCSI devices  
External SCSI Cable [VHDCI-HDCI] (10m) <N800/400>  
<Connection>  
- N800: Onboard SCSI Controller to S10/External SCSI devices  
- N400: PGBCBLS011 to S10/External SCSI devices  
Fast Ethernet Cable for node-node connection in Clustering configuration (5m)  
Fibre Channel Cable (2m)  
Fast Ethernet Cable  
Fibre Channel Cable  
Fibre Channel Cable  
Fibre Channel Cable  
Gigabit Ethernet Controller  
(Fibre)  
DCL-FEA05U  
GP5-311  
GP5-312  
Fibre Channel Cable (5m)  
GP5-313  
Fibre Channel Cable (15m)  
PG-188  
1000BASE-SX/PCI64bit-66MHz/Driver is included  
*Fibre Channel cable is required : GP5-311/2m, GP5-312/5m, GP5-313/15m  
PGB188  
[CTO option]  
PG-185  
Fast Ethernet Controller  
Fibre Channel Controller  
Remote Service Board  
100BASE-TX/10BASE-T/PCI64bit/Driver is included  
PGB185  
*Twisted pair cable (category5:100BASE-TX/category3:10BASE-T) is required  
[CTO option]  
PG-FC102  
1GB Optical, FC-AL/FC-Fabric, Duplex SC port for external device  
PGURSB101  
PG-RSBOP2  
Optional remote server management board (PCI)  
CPU, External Interface (10BASE-T/RS232C), External PowerSupply  
(AC adapter - Option) are on the board  
Remote Service Board Kit B  
Optional Kit for mounting RSB  
ServerView for RSB CD-ROM, Connector, Power Code are included  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications are subject to change without notice. For the latest detailed information, contact your local representative.  
All brand names and product names are trademarks and registered trademarks of their respective holders.  
©2001 Fujitsu Limited. All rights reserved. Printed in Japan.  
PRIMERGY (IA-Servers) Business Development Dept.  
Business Development and Marketing Division  
Computer Systems Group  
Phone: +81-3-3548-3810 Fax: +81-3-3548-3776  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion Cassette Player AX430 User Manual
Compaq Personal Computer SR1602HM User Manual
Creative Labs Digital Camera 02VF016000000 User Manual
Curtis MP3 Player CD149 User Manual
Cypress Computer Hardware CY7C604XX User Manual
Dell Riding Toy T20 User Manual
Elation Professional Work Light PAR56 User Manual
Electro Voice Portable Speaker EJ1 X User Manual
Fender Guitar 194470 User Manual
GE Trash Compactor 165D4700P385 User Manual