PRIMERGY N800 Datacenter Server
System Configuration Guide (Ver.2) (Jul / 2001)
2
8
9
PRIMERGY N800
Configuration of Clustering
Rackmount
Index
The numbers on the left hand side of each
page correspond to the various options
available with PRIMERGY as follows
1
2
3
4
5
6
7
8
9
CPU slot
RAM module slot
3.5 inch HDD Bay
5 inch Bay
RS-232C
PCI slot
ISA slot
Redundant PSU
Others
Key to
Or
And
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
ꢀ Install Operating System
- Boot disk can be an external disk. In this case, the disk must be connected to PG-142B RAID Controller.
- Basically, installation should be done by "Installation and Startup Service". So please contact with your local sales representative.
Mounting devices
- In N800, there are four internal HDD bays (2bays/1ch x 2)
- N800 has one internal 5" bay in chassis for DDS4 (In case of SCSI connection, the DDS4 is available for
daisy-chain connection with HDD)
- PRIMERGY S10 (Backup Cabinet) is available if " more then two backup devices" or "backup devices except for DDS4"
are installed.
ꢀ Configuration Chart
N800
PRIMERGY S10
(PGUR1BC3)
Onboard SCSI Controller
(Ultra2 Wide x 2)
ChB
ChA
or
PRIMERGY S10
(PGUR1BC3)
DDS4
(Option)
SCSI Controller
(PG-126)
Ch0
Ch1
RAID Controller (Standard)
(Ultra160 x 2)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
ꢀ Connection Matrix
For Internal HDD/PRIMERGYS30
Channel 0
Standard
RAID Controller
For Internal HDD/PRIMERGYS30
Channel 1
PRIMERGY N800
Connection of internal HDD and internal backup devices
For Internal Backup device/Internal HDD
Onboard
SCSI
Ultra2 Wide A
Ultra2 Wide B
For PRIMERGY S10/Internal HDD
Internal HDD
Backup device
One device is connected
Connection Pattern
Host
Two devices are connected
Wide Narrow device
Configuration SCSI
Interface
Cable
Internal HDD
In case that
DDS4 is
Except for Narrow
DDS4
device x 2 device x 2 and
Wide device
connected
Up to four HDDs can be
Onboard SCSI (Ultra2 Wide Bch)
PRIMERGY S10 (PGUR1BC3)
SCSI Cable (PG-CBLS007/008/009)
or
Array
Standard
Cable(X2) installed
Onboard SCSI
(Ach)
Configuration Ultra160
RAID Controller (Ch0/1) (Standard 1) 9GB, 10,000rpm
equipment) 2) 18GB, 10,000rpm
3) 18GB, 15,000rpm
SCSI Controller (PG-126)
PRIMERGY S10 (PGUR1BC3)
SCSI Cable (PG-CBLS001/002/003)
4) 36GB, 10,000rpm
- In case of SCSI configuration (Up to four HDDs can be mounted), internal DDS4 can be connected to ChA of Onboard SCSI by daisy chain.
- when connecting RAID Controller with PRIMERGY S30, or SCSI Controller with Internal HDD, both SCSI Channel of Onboard SCSI Controller must be connected
to Internal HDD.
Mountable I/O options
N800
Maximum
number
Cards
Product ID
Bus
of cards Total
REMARKS
mounted
10
SCSI Controller
(Ultra Wide Diff)
SCSI Controller
(Ultra2 Wide LVD)
PG-123
PCI64
PCI64
PCI64
PCI64
PCI64
4
2
4
1
4
4
5
4
For external disk array
PG-126
Fibre Channel Controller PG-FC102
RAID Controller
(Ultra160 LVD)
RAID Controller
(Ultra160 LVD)
Standard
Mounted in PCI slot1
Equipment
PG-142B/C
EthernetController
(1000Base-SX)
EthernetController
(100Base-TX)
PG-188
PCI64
PCI64
PCI64
2
1
2
Standard
Equipment
PG-185
Mounted in PCI slot3
EthernetController
(100Base-TX)
For Remote Management
Remote Service Board
PGURSB101
PCI64
1
4
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Connection Table
PGTN8BHRD2
PGTN8BGRD2
Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(2MB), Memory:1GB(ECC), HDD:Option
Rackmount Type 2 x Pentium® lll Xeon™ 700MHz(1MB), Memory:1GB(ECC), HDD:Option
Rackmount Type
<Items>
CPU Field Upgrade :
Memory addition :
Go to A
Go to B
Go to C
Go to D
Go to E
Go to F
Go to G
Standard Memory Conversion :
Internal Hard Disk Drive connection
External Hard Disk Drive connection
Backup devices
Others (NIC etc.)
CPU
Max : 8CPUs
CPU Field Upgrade Kit - 74 (Pentium III Xeon 700MHz (2MB) x1)
1
A:
GP5-FG20HT/GP5BFG20HT
Standard : 2CPUs
CPU Field Upgrade Kit - 73 (Pentium III Xeon700MHz (1MB) x1)
GP5-FG20GT/GP5BFG20GT
Memory
Standard memory : 1GB (256MB-DIMMx4)
Max. memory: 32GB
Additional Memory - 512MB (256MB-DIMMx2)
GP5-RM51J/GP5BRM51J
B:
2
2
Additional Memory - 1GB (512MB-DIMMx2)
GP5-RM1J/GP5BRM1J
Additional Memory Board
PG-RB103/PGBRB103
Additional Memory - 2GB (1GB-DIMMx2)
GP5-RM2J/GP5BRM2J
Standard Memory Conversion
C:
Standard Memory Conversion Kit-2GB (512MB SDRAM-DIMMx4)
2
PGBRU2C
Standard Memory Conversion Kit-4GB (1GB SDRAM-DIMMx4)
PGBRU4C
Internal Hard Disk
Max : 4
Hard Disk - 9GB (Ultra160 10,000rpm)
(Hot Plug)
D:
6
Standard RAID Controller
PG-HDH91B/PGBHDH91B
(Ultra160/2ch/64MB cache)
Hard Disk - 18GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH81B/PGBHDH81B
Standard RAID Controller Conversion Kit
(Standard RAID to PG-142C)
(Ultra160/2ch/64MB Cache/BBU)
PGB1U42C1
Hard Disk - 18GB (Ultra160 15,000rpm)
(Hot Plug)
PG-HDH85B/PGBHDH85B
Hard Disk - 36GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH61B/PGBHDH61B
5
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
External Hard Disk
Max:13
Hard Disk - 9GB (Ultra160 7,200rpm)
(Hot Plug)
E:
6
RAID Controller
Ultra160/2ch
PG-HDH97B/PGBHDH97B
SCSI Cable (2m)
PRIMERGY S30
PGUR1DC6
64MB Cache
PG-CBLS004
Hard Disk - 18GB (Ultra160 72,00rpm)
(Hot Plug)
PG-142B/PGB142B
PG-HDH87B/PGBHDH87B
RAID Controller
Ultra160/2ch
SCSI Cable (5m)
PG-CBLS005
Hard Disk - 9GB (Ultra160 10,000rpm)
(Hot Plug)
64MB Cache/BBU
PG-142C/PGB142C
PG-HDH91B/PGBHDH91B
Hard Disk - 18GB (Ultra160 10,000rpm)
(Hot Plug)
SCSI Cable (10m)
PG-CBLS006
PG-HDH81B/PGBHDH81B
Hard Disk - 18GB (Ultra160 15,000rpm)
(Hot Plug)
PG-HDH85B/PGBHDH85B
Hard Disk - 36GB (Ultra160 10,000rpm)
(Hot Plug)
PG-HDH61B/PGBHDH61B
Power Supply Module
Max:1
PGUPU103/PGBUPU103
Backup Devices
Up to four Tape units can be mounted
Onboard SCSI Controller
Tape Drive DLT8000
F:
PRIMERGY S10
PGUR1BC3
PG-DL401/PGBDL401
4
Two 5" bays are occupied
SCSI Cable (1.8m)
PG-CBLS007
Tape Drive DLT7000
PG-DL351/PGBDL351
Two 5" bays are occupied
SCSI Cable (5m)
PG-CBLS008
Tape Drive DLT4000
PG-DL201/PGBDL201
Two 5" bays are occupied
Tape Drive LTO
SCSI Cable (10m)
PG-CBLS009
PG-LT101/PGBLT101
Tape Drive SLR100
PG-SL101/PGBSL101
6
SCSI Controller U2W
PG-126/PGB126
SCSI Cable(1.5m)
PG-CBLS001
Tape Drive SLR60
PG-SL601/PGBSL601
SCSI Cable (5m)
PG-CBLS002
Tape Drive SLR50
PG-ML301/PGBML301
Tape Drive DAT DDS4
PG-DT401/PGBDT401
SCSI Cable (10m)
PG-CBLS003
Tape Drive DAT DDS3
PG-DT301/PGBDT301
Tape Drive DAT DDS4 Autoloader
PG-DTA102/PGBDTA102
Two 5" bays are occupied
Tape Drive DAT DDS3 Autoloader
PG-DTA101/PGBDTA101
Two 5" bays are occupied
6
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Onboard SCSI Controller
Tape Drive DAT DDS4
PG-DT401/PGBDT401
4
Only one DDS4 can be mounted in 5"bay
Others
Gigabit Ethernet Controller (1000Base-SX))
PG-188/PGB188
6
6
6
6
G:
Fast Ethernet Controller (100Base-TX)
PG-185/PGB185
Fibre Channel Controller
PG-FC102
Remote Service Board
PGURSB101
Remote Service Board Kit B
PG-RSBOP2
7
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Configuration of Microsoft® Clustering
<PRIMERGY N800 - FUJITSU GR720>
Fibre Channel Controller
PG-FC102
Fibre Channel Cable
6
6
6
GP5-311 (2m)/312(5m)/313(15m)
Fibre Channel Controller Fibre Channel Cable
PG-FC102 GP5-311 (2m)/312(5m)/313(15m)
Disk Array
FUJITSU
GR720
Ethernet Controller
Controller of
Disk Array
(Primary)
PG-185/PGB185
Fast Ethernet Cable
DCL-FEA05U
Ethernet Controller
PG-185/PGB185
6
6
6
Controller of
Disk Array
(Secondary)
Fibre Channel Controller Fibre Channel Cable
PG-FC102 GP5-311 (2m)/312(5m)/313(15m)
Fibre Channel Controller
PG-FC102
Fibre Channel Cable
GP5-311 (2m)/312(5m)/313(15m)
<PRIMERGY N800 - EMC® Clariion®/Symmetrix®>
Disk Array
6
6
6
FC Host Bus Adapter
FC Host Bus Adapter
Fibre Channel Cable
EMC®
Clariion® FC5300
Clariion® FC4500
Symmetrix®8000
Fibre Channel Cable
Ethernet Controller
Controller of
Disk Array
(Primary)
PG-185/PGB185
Fast Ethernet Cable
DCL-FEA05U
Ethernet Controller
PG-185/PGB185
6
6
6
Controller of
Disk Array
(Secondary)
FC Host Bus Adapter
Fibre Channel Cable
FC Host Bus Adapter
Fibre Channel Cable
Please contact your local FUJITSU sales representative in the case as follows;
- In case of connecting with EMC disk array, each component surrounded by
"Fibre Channel Cable", "Fibre Channel HUB") should be EMC's.
- As for the certified configuration of Windows2000 Datacenter Server.
- Four nodes Clustering.
("Fibre Channel Adapter with driver SW",
8
Download from Www.Somanuals.com. All Manuals Search And Download.
System Configuration
Rackmount
Rack and Rack Options
40U Rack
GP5-R1RC6
40U Rack & Rack Coupling Kit
GP5-R1RC7
36U Rack
36U Rack & Rack Coupling Kit
PG-R3RC1
PG-R3RC2
CPU or DISK node
24U Rack
GP5-R2RC3
24U Rack & Rack Coupling Kit
GP5-R2RC4
24U Rack
PG-R4RC1
24U Rack & Rack Coupling Kit
PG-R4RC2
Quake Proof Stabilizer: PG-R3ST1(For PG-R3RCx/PG-R4RCx)
Quake Proof Stabilizer: PG-R1ST1(For GP5-R1RCx/GP5-R2RCx)
Component Shelf
GP5-R1TB7
Keyboard/Monitor Shelf Kit
GP5-R1TB6
(Up to 8 servers connection)
Keyboard/Monitor Cable
GP5-418(5.0m)
Keyboard/Monitor Enhanced Switch
GP5-SB102
Flat Display
GP5UR1DP11
Keyboard/Monitor Cable
GP5-414(1.8m)
(Up to 4 servers connection)
Keyboard/Monitor Cable
GP5-411 (3.0m)
Keyboard/Monitor Enhanced Switch
GP5-SB101
Enhanced Keyboard
GP5-R1KB2
Up to eight servers can be connected to one GP5-SB102, and up to
64 servers can be connected with nine GP5-SB102 in cascade connection
(Keyboard Monitor Cable: GP5-414 is required)
* In case of Cascade connection, AC adapter is required.
GP5-SB102
GP5-SB102
GP5-414
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware
Hardware List
Product
Product ID
Remarks
CPU Field Upgrade Kit-74
CPU Field Upgrade Kit-73
Additional Memory 2GB
Additional Memory 1GB
Additional Memory 512MB
GP5-FG20HT
GP5BFG20HT
[CTO option]
GP5-FG20GT
GP5BFG20GT
[CTO option]
GP5-RM2J
Pentiumlll Xeon(700MHz)/32KB+2MBcachex1,Placed on motherboard
Includes one CPU
Pentiumlll Xeon(700MHz)/32KB+1MBcachex1,Placed on motherboard
Includes one CPU
SDRAM-DIMM (100MHz) 1024MBx2 (Buffered CL/2)
SDRAM-DIMM (100MHz) 512MBx2 (Buffered CL/2)
SDRAM-DIMM (100MHz) 256MBx2 (Buffered CL/2)
GP5BRM2J
[CTO option]
GP5-RM1J
GP5BRM1J
[CTO option]
GP5-RM51J
GP5BRM51J
[CTO option]
PGBRU4C
Standard Memory conversion 1GB to 4GB
Standard Memory Conversion Kit-4GB
Standard Memory Conversion Kit-2GB
Additional Memory Board
[CTO option]
PGBRU2C
Standard Memory conversion 1GB to 2GB
[CTO option]
PG-RB103
Additional memory board for mounting more than 16 DIMMs
PGBRB103
[CTO option]
PG-HDH61B
PGBHDH61B
[CTO option]
PG-HDH85B
PGBHDH85B
[CTO option]
PG-HDH81B
PGBHDH81B
Hard Disk Drive-36GB
Hard Disk Drive-18GB
Hard Disk Drive-18GB
Hard Disk Drive-9GB
36.4GB Ultra160 Hotplug HDD <10000rpm> 1"height
<N800, N400 and S30>
18.2GB Ultra160 Hotplug HDD <15000rpm>1"height
<N800, N400 and S30>
18.2GB Ultra160 Hotplug HDD <10000rpm>1"height
<N800, N400 and S30>
available with PRIMERGY as follows
9.1GB Ultra160 Hotplug HDD <10000rpm> 1"height
<N800, N400 and S30>
PG-HDH91B
PGBHDH91B
[CTO option]
PGUR1DC6
PRIMERGY S30
Rackmount(3U) Hard Disk Node Ultra160 / 14 Hotplug HDD bays
(1"x14 HDD/2ch) / Maximum capacity is 509.6GB (36.4GB x14)
Redundant&Hotplug FAN(Std.)/PSU(Opt.)
(Storage Subsystem)
1. PG-142B/PG-142C/PG-143B - PG-CBLS004/PG-CBLS005/PG-CBLS006
2. GP5-150/1501- PG-CBLS004/PG-CBLS005/PG-CBLS006
<Available HDD>
PG-HDH61B/PG-HDH85B/PG-HDH81B/PG-HDH91B/PG-HDH87B/PG-HDH97B
Only for Array configuration, CTO is available
Tape Drive DAT DDS4
(DAT Unit)
PG-DT401
Internal DAT unit (DDS-4:20GB-40GB)
PGBDT401
[CTO option]
PG-DT301
Tape Drive DAT DDS3
(DAT Unit)
Internal DAT unit (DDS-3:12-24GB)
PGBDT301
[CTO option]
PG-DTA102
PGBDTA102
[CTO option]
*1 PRIMERGY S10 is required to mount
Tape Drive DAT DDS4 Autoloader
(DAT Autoloader)
Internal DAT autoloader (DDS-4: 20GB-40GB) 6cassetes
Two 5" bays are occupied
*1 PRIMERGY S10 is required to mount
Tape Drive DAT DDS3 Autoloader
(DAT Autoloader)
PG-DTA101
PGBDTA101
[CTO option]
Internal DAT autoloader (DDS-3: 12GB-24GB) 6cassetes
Two 5" bays are occupied
*1 PRIMERGY S10 is required to mount
Tape Drive DLT4000
(DLT Unit)
PG-DL201
PGBDL201
[CTO option]
PG-DL351
PGBDL351
[CTO option]
Internal DLT unit (DLT4000: 20GB-40GB) Two 5" bays are occupied
*1 PRIMERGY S10 is required to mount
Tape Drive DLT7000
(DLT Unit)
Internal DLT unit(DLT7000: 35-70GB) Two 5"bays are required and occupied
*1 PRIMERGY S10 is required to mount
Tape Drive DLT8000
(DLT Unit)
PG-DL401
PGBDL401
[CTO option]
Internal DLT unit(DLT8000: 40-80GB) Two 5"bays are required and occupied
*1 PRIMERGY S10 is required to mount
Tape Drive LTO
(LTO Unit)
PG-LT101
Internal LTO unit (LTO: 100-200GB)
PGBLT101
[CTO option]
*1 PRIMERGY S10 is required to mount
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware
Hardware List
Product
Product ID
Remarks
Tape Drive SLR50
(Tape Unit)
PG-ML301
PGBML301
[CTO option]
PG-SL601
Internal Tape unit (SLR50: 25-50GB)
*1 PRIMERGY S10 is required to mount
Tape Drive SLR60
(Tape Unit)
Internal Tape unit (SLR60: 30-60GB)
*1 PRIMERGY S10 is required to mount
PGBSL601
[CTO option]
PG-SL101
Tape Drive SLR100
(Tape Unit)
Internal Tape unit (SLR100: 50-100GB)
*1 PRIMERGY S10 is required to mount
PGBSL101
[CTO option]
PGUR1BC3
PRIMERGY S10
(Backup Cabinet)
Rackmount 3U 5" bay node for N800/N400/H200
Up to four Tape units can be mounted
<Available Backup devices>
Occupy two bays : PG-DL201/PG-DL351/PG-DL401/PG-DTA101/PG-DTA102
Occupy one bay: PG-SL101/PG-SL601/PG-ML301/PG-DT401/PG-DT301
*CTO is available
Power Supply Module
Power Supply Module
40U Rack
PGUPU103
PGBUPU103
[CTO option]
PG-PU102
Redundant PSU (500W) *Power Code is required
<PRIMERGY S30>
*1 S30 is available on N800/N400/MS610/H200
Redundant PSU (500W) *Power Code is required
<PRIMERGY N400/S10>
PGBPU102
[CTO option]
GP5-R1RC6
*1 S10 is available on N800/N400/H200
19'' 40U Locker , Front door,rear door,side panel,earthquake proof
board ,blank panel is attached. Size(WxDxH)mm:600x900x2000
<Number of units required for installation>
N800: 7U
PGUR1DC6: 3U/PGUR1BC3: 3U
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)
Component shelf: 5U
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)
Color: Black
40U Rack&Rack
Coupling Kit
GP5-R1RC7
PG-R3RC1
19''40U Locker + connection metal fittings Front door,rear
door,concatenation frame,blank panel is attached.
Color: Black
36U Rack
19'' 36U Locker , Front door,rear door,side panel,earthquake proof
board ,blank panel is attached. Size(WxDxH)mm:700x950x1800
<Number of units required for installation>
N800: 7U
PGUR1DC6: 3U/PGUR1BC3: 3U
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)
Component shelf: 5U
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)
Color: Black
36U Rack&Rack
Coupling Kit
PG-R3RC2
19''36U Locker + connection metal fittings Front door,rear
door,concatenation frame,blank panel is attached.
Color: Black
24U Rack
GP5-R2RC3
19'' 24U Locker , Front door,rear door,side panel,earthquake proof
board, blank panel is attached. Size(WxDxH)mm:700x950x1267
<Number of units required for installation>
N800: 7U
PGUR1DC6: 3U/PGUR1BC3: 3U
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)
Component shelf: 5U
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)
Color: Black
24U Rack&Rack
Coupling Kit
GP5-R2RC4
19''24U Locker + connection metal fittings Front door,rear
door,concatenation frame,blank panel is attached.
Color: Black
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware
Hardware List
Product
Product ID
Remarks
24U Rack
PG-R4RC1
19'' 24U Locker , Front door,rear door,side panel,earthquake proof
board, blank panel is attached. Size(WxDxH)mm:600x900x1200
<Number of units required for installation>
N800: 7U
PGUR1DC6: 3U/PGUR1BC3: 3U
Keyboard/Monitor Shelf: 9U(for installation 15''CRT),1U(for installation Keyboard)
Component shelf: 5U
CRT/KB switch: Mounted at side of CRT (occupies same U as CRT)
Color: Black
24U Rack&Rack
Coupling Kit
PG-R4RC2
19''24U Locker + connection metal fittings Front door,rear
door,concatenation frame,blank panel is attached.
Color: Black
Component Shelf
GP5-R1TB7
GP5-R1TB6
Shelf to fit peripheral device into 40U Rack, Table size:400(W)x500(D)
Color: Black
Keyboard/Monitor Shelf Kit
Used to store display unit (CRT), a keyboard (KB), and a mouse on a rack.
Color: Black
Keyboard/Monitor
Enhanced Switch
Keyboard/Monitor
Enhanced Switch
GP5-SB101
GP5-SB102
Switch enables sharing of a set of CRT,keyboard,and mouse by two
or more servers (up to four servers).
Switch enables sharing of a set of CRT,keyboard,and mouse by two
or more servers (up to eight servers). Shared up to 64 servers in
cascade connection.* AC adapter is required for cascade connection
(Procured locally)
Keyboard/Monitor Cable
GP5-418
GP5-414
GP5-411
For connection with switch (For connection GP5-SB102) (5.0m)
For cascade connection between GP5-SB102 (1.8m)
CRT/KB cable for connection Server with GP5-SB101,
CRT cablex1,KB/Mouse cablex1 is attached
87Key keyboard for Rackmountable type
Rackmountable LCD display with Keyboard, 2U height
<GP5UR1DP1 + GP5-R1RK7>
Keyboard/Monitor Cable
Keyboard/Monitor Extension Cables
Enhanced Keyboard
Flat Display
GP5-R1KB2
GP5UR1DP11
SCSI Controller UW
PG-123
Ultra Wide HVD (High Voltage Differential)/1ch/SMART HDD is not
supported/ Up to 40MB/s of synchronous transfer support
<Connector>
(SCSI Card)
PGB123
[CTO option]
- 68-pin connector for external SCSI
- 68-pin connector for internal SCSI
- 50-pin connector for internal SCSI
<Use>
For connection with external Disk Array
* SCSI cable is required.
SCSI Controller U2W
(SCSI Card)
PG-126
Ultra2 Wide(LVD)/1ch/SMART HDD/Up to 80MB/s transfer speed
<Connector>
PGB126
[CTO option]
- 68-pin connector for external SCSI (Ultra2 Wide)
- 68-pin connector for internal SCSI (Ultra2 Wide)
- 68-pin connector for internal SCSI (Ultra Wide)
- 50-pin connector for internal SCSI (Ultra Wide)
<Use>
For connection internal backup device/PRIMERGY S10
RAID Controller, Ultra160/2ch/64MB cache/RAID level 0,1,5,6 (0+1)are supported
For internal/external array configuration
RAID Controller U160 2Channels
(RAID Card)
PG-142B
PGB142B
[CTO option]
PG-142C
RAID Controller U160 2Channels
(RAID Card)
RAID Controller, Ultra160/2ch/64MB cache/Battery Backup/
RAID level 0,1,5,6(0+1) are supported
For internal/external array configuration
Convert Standard RAID Controller to PG-142C
<N800>
PGB142C
[CTO option]
PGB1U42C1
[CTO option]
Standard RAID Controller
Conversion Kit
External SCSI Cable [HDCI-HDCI] (1.5m)
<Connection>
SCSI Cable
SCSI Cable
SCSI Cable
PG-CBLS001
PG-CBLS002
PG-CBLS003
- SCSI Controller and S10/External SCSI devices
External SCSI Cable [HDCI-HDCI] (5m)
<Connection>
- SCSI Controller and S10/External SCSI devices
External SCSI Cable [HDCI-HDCI] (10m)
<Connection>
- SCSI Controller and S10/External SCSI devices
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware
Hardware List
Product
Product ID
PG-CBLS004
PG-CBLS005
PG-CBLS006
PG-CBLS007
Remarks
SCSI Cable
SCSI Cable
SCSI Cable
SCSI Cable
External SCSI Cable [VHDCI-VHDCI] (2m)
<Connection>
- RAID Controller and S30
External SCSI Cable [VHDCI-VHDCI] (5m)
<Connection>
- RAID Controller and S30
External SCSI Cable [VHDCI-VHDCI] (10m)
<Connection>
- RAID Controller and S30
External SCSI Cable [VHDCI-HDCI] (1.8m) <N800/400>
<Connection>
- N800: Onboard SCSI Controller to S10/External SCSI devices
- N400: PGBCBLS011 to S10/External SCSI devices
External SCSI Cable [VHDCI-HDCI] (5m) <N800/400>
<Connection>
SCSI Cable
SCSI Cable
PG-CBLS008
PG-CBLS009
- N800: Onboard SCSI Controller to S10/External SCSI devices
- N400: PGBCBLS011 to S10/External SCSI devices
External SCSI Cable [VHDCI-HDCI] (10m) <N800/400>
<Connection>
- N800: Onboard SCSI Controller to S10/External SCSI devices
- N400: PGBCBLS011 to S10/External SCSI devices
Fast Ethernet Cable for node-node connection in Clustering configuration (5m)
Fibre Channel Cable (2m)
Fast Ethernet Cable
Fibre Channel Cable
Fibre Channel Cable
Fibre Channel Cable
Gigabit Ethernet Controller
(Fibre)
DCL-FEA05U
GP5-311
GP5-312
Fibre Channel Cable (5m)
GP5-313
Fibre Channel Cable (15m)
PG-188
1000BASE-SX/PCI64bit-66MHz/Driver is included
*Fibre Channel cable is required : GP5-311/2m, GP5-312/5m, GP5-313/15m
PGB188
[CTO option]
PG-185
Fast Ethernet Controller
Fibre Channel Controller
Remote Service Board
100BASE-TX/10BASE-T/PCI64bit/Driver is included
PGB185
*Twisted pair cable (category5:100BASE-TX/category3:10BASE-T) is required
[CTO option]
PG-FC102
1GB Optical, FC-AL/FC-Fabric, Duplex SC port for external device
PGURSB101
PG-RSBOP2
Optional remote server management board (PCI)
CPU, External Interface (10BASE-T/RS232C), External PowerSupply
(AC adapter - Option) are on the board
Remote Service Board Kit B
Optional Kit for mounting RSB
ServerView for RSB CD-ROM, Connector, Power Code are included
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications are subject to change without notice. For the latest detailed information, contact your local representative.
All brand names and product names are trademarks and registered trademarks of their respective holders.
©2001 Fujitsu Limited. All rights reserved. Printed in Japan.
PRIMERGY (IA-Servers) Business Development Dept.
Business Development and Marketing Division
Computer Systems Group
Phone: +81-3-3548-3810 Fax: +81-3-3548-3776
Download from Www.Somanuals.com. All Manuals Search And Download.
|