Regulatory Compliance  
FCC Class A Part 15 CSA/CUS  
7 September 2007  
ADM-S08  
FortiGate-ASM-S08  
01-30005-0413-20070907  
LED  
State  
Description  
Blue  
Ejection latch open. The module is ready for removal.  
HS  
Flashing  
Ejection latch opened during system operation.  
LED currently not in use.  
OOS  
Amber  
Off  
The module is properly inserted in the FortiGate unit.  
The module is not receiving power from the FortiGate unit.  
LED currently not in use.  
ACT/RDY  
PORT  
Installing the AMC Module  
It is important to carefully seat the FortiGate ASM-S08 module all  
the way into the chassis. Only then will the FortiGate ASM-S08  
module power-on and start up correctly.  
5. Pull out the hot swap latch on the right-hand side of the  
module if pushed in.  
6. Insert the module by applying moderate force to the front  
faceplate near the upper edge to slide the module into the  
slot.  
CAUTION: The ambient room temperature of a FortiGate unit with  
the ASM-S08 module installed must be no greater than 35˚C (95˚F).  
The module should glide smoothly into the chassis. If you  
encounter any resistance while sliding the module in, the  
module could be aligned incorrectly. Pull the module back  
out and try inserting it again.  
To complete this procedure, you need:  
A FortiGate chassis with an empty AMC single-width (SW)  
opening.  
7. Press the hot swap latch firmly to lock in the module.  
8. Power on the FortiGate unit.  
To avoid any electrostatic discharge, install in a static free area.  
Removing the AMC module  
Should you need to remove the ASM-S08, shut down the Forti-  
FortiGate ASM-S08 modules are not hot swappable. The procedure  
for inserting the FortiGate ASM-S08 module into a FortiGate chas-  
sis slot requires the FortiGate unit to be powered off.  
Gate unit using proper shut down procedures.  
To remove the ASM-S08 module  
FortiGate ASM-S08 modules must be protected from static dis-  
charge and physical shock. Only handle or work with FortiGate  
ASM-S08 modules at a static-free workstation. To avoid any  
electrostatic discharge (ESD) when handling FortiGate ASM-S08  
modules, install in a static free area.  
1. Ensure the FortiGate unit is powered off before proceeding.  
2. To avoid any electrostatic discharge (ESD) when handling  
FortiGate ASM-S08 modules, install in a static free area.  
3. Pull the hot-swap latch on the right-hand side of the module  
to the extended position to unlock the module from the  
FortiGate unit.  
To insert a FortiGate ASM-S08 module into a FortiGate chassis  
1. Ensure the FortiGate unit is powered off before proceeding.  
4. Gently pull the hot swap latch to remove the module.  
2. Remove the panel block on the FortiGate unit using the hot  
swap latch.  
3. Insert the FortiGate ASM-S08 module into the empty slot in the  
chassis. Ensure the Fortinet logo is right-side up. It should be  
on the upper-right corner of the module.  
4. Carefully guide the module into the chassis.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cooper Bussmann Switch EDSC2199 User Manual
Craftsman Air Compressor 91972427 User Manual
Crate Amplifiers Musical Instrument Amplifier GTX3500H User Manual
Danby Microwave Oven DMW1104BL User Manual
Electro Voice Portable Speaker T15i User Manual
Ferris Industries Lawn Mower is3100z series User Manual
Generac Power Systems Portable Generator 16L 18 kW User Manual
GE Ventilation Hood 30 User Manual
GE Washer Dryer WSM2780 Gas User Manual
Glen Dimplex Home Appliances Ltd Cooktop 60T User Manual