HS
OOS
ACT/RDY
© Copyright 2007 Fortinet Incorporated. All rights reserved.
Products mentioned in this document are trademarks or registered trade-
marks of their respective holders.
PORT
Regulatory Compliance
FCC Class A Part 15 CSA/CUS
7 September 2007
ADM-S08
FortiGate-ASM-S08
01-30005-0413-20070907
LED
State
Description
Blue
Ejection latch open. The module is ready for removal.
HS
Flashing
Ejection latch opened during system operation.
LED currently not in use.
OOS
Amber
Off
The module is properly inserted in the FortiGate unit.
The module is not receiving power from the FortiGate unit.
LED currently not in use.
ACT/RDY
PORT
Installing the AMC Module
It is important to carefully seat the FortiGate ASM-S08 module all
the way into the chassis. Only then will the FortiGate ASM-S08
module power-on and start up correctly.
5. Pull out the hot swap latch on the right-hand side of the
module if pushed in.
6. Insert the module by applying moderate force to the front
faceplate near the upper edge to slide the module into the
slot.
CAUTION: The ambient room temperature of a FortiGate unit with
the ASM-S08 module installed must be no greater than 35˚C (95˚F).
The module should glide smoothly into the chassis. If you
encounter any resistance while sliding the module in, the
module could be aligned incorrectly. Pull the module back
out and try inserting it again.
To complete this procedure, you need:
•
•
A FortiGate chassis with an empty AMC single-width (SW)
opening.
7. Press the hot swap latch firmly to lock in the module.
8. Power on the FortiGate unit.
To avoid any electrostatic discharge, install in a static free area.
Removing the AMC module
Should you need to remove the ASM-S08, shut down the Forti-
FortiGate ASM-S08 modules are not hot swappable. The procedure
for inserting the FortiGate ASM-S08 module into a FortiGate chas-
sis slot requires the FortiGate unit to be powered off.
Gate unit using proper shut down procedures.
To remove the ASM-S08 module
FortiGate ASM-S08 modules must be protected from static dis-
charge and physical shock. Only handle or work with FortiGate
ASM-S08 modules at a static-free workstation. To avoid any
electrostatic discharge (ESD) when handling FortiGate ASM-S08
modules, install in a static free area.
1. Ensure the FortiGate unit is powered off before proceeding.
2. To avoid any electrostatic discharge (ESD) when handling
FortiGate ASM-S08 modules, install in a static free area.
3. Pull the hot-swap latch on the right-hand side of the module
to the extended position to unlock the module from the
FortiGate unit.
To insert a FortiGate ASM-S08 module into a FortiGate chassis
1. Ensure the FortiGate unit is powered off before proceeding.
4. Gently pull the hot swap latch to remove the module.
2. Remove the panel block on the FortiGate unit using the hot
swap latch.
3. Insert the FortiGate ASM-S08 module into the empty slot in the
chassis. Ensure the Fortinet logo is right-side up. It should be
on the upper-right corner of the module.
4. Carefully guide the module into the chassis.
Download from Www.Somanuals.com. All Manuals Search And Download.
|