FieldServer Computer Drive FS 8700 82 User Manual

A Sierra Monitor Company  
Driver Manual  
(Supplement to the FieldServer Instruction Manual)  
FS-8700-82 Carrier DataLink  
APPLICABILITY & EFFECTIVITY  
Effective for all systems manufactured after May 1, 2001  
Driver Version:  
1.03  
Document Revision: 5  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 3 of 31  
1.  
Carrier DataLink Description  
The Carrier DataLink driver allows the FieldServer to transfer data to and from devices over  
either RS-232 or RS-485 using Carrier DataLink protocol. The FieldServer can emulate either a  
Server or Client.  
The Carrier DataLink Serial Driver allows variables to be read and written in system elements  
connected to a Carrier Comfort Network communication bus. Up to 15 system elements may be  
connected to a DataLink Device. Display, Occupancy, Set Point Tables and Carrier Comfort  
Network (CCN) variables may be read or written.  
The DataLink device provides a gateway to CCN devices. This driver polls the DataLink device  
which in turn reads/writes data to the CCN devices.  
Carrier limits the number of CCN devices that can polled from a DataLink Device as well as the  
data that can be transferred between some CCN devices and the DataLink device. For  
information on these limitations please consult the Carrier Corporation.  
The driver is an active client driver. This means that it initiates read/write polls with the DataLink  
device which is expected to provide responses. Server functionality is not intended to provide  
full emulation of DataLink Devices but can be extended on request.  
The driver is configured to allow data tables to be read from the CCN devices via the DataLink  
device. As the tables typically contain more than one data element, the retrieved data is stored  
in a number of consecutive FieldServer data array locations in the FieldServer. The individual  
values cannot be scaled before they are stored. The driver can provide descriptions for each of  
the table values retrieved. Descriptions are stored in ASCII in a separate data array.  
The driver can be configured to read a specific variable from a CNN device and store its value  
using optional scaling in a configurable location in a FieldServer data array.  
The driver can be configured to write a value (using optional scaling) from a FieldServer data  
array to a specific variable in a CNN device, provided that the variable allows its value to be  
written.  
The driver has no advanced knowledge of the CCN devices and their data tables. Therefore it  
cannot validate table names or variable names specified in the configuration file. This means  
that the driver handles each table in a generic way, without regard for the particular variables  
that constitute the tables.  
It is important that you understand the limitations and exclusions of this driver. Refer to Section  
5.4 for more information.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 4 of 31  
2.  
Driver Scope of Supply  
2.1. Supplied by FieldServer Technologies for this driver  
FieldServer Technologies PART #  
FS-8915-10  
FS-8917-17  
DESCRIPTION  
UTP cable (7 foot) for RS-232 use  
RJ45 to DB25M connection adapter  
Driver Manual.  
FS-8700-82  
2.2.  
PART #  
Provided by Suppler of 3rd Party Equipment  
DESCRIPTION  
Carrier DataLink Card  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 5 of 31  
3.  
Hardware Connections  
The FieldServer is connected to the Carrier DataLink device as shown below. Ensure that the  
device to be connected to is in fact the DataLink device and not the DataPort device which is  
similar looking.  
Configure the DataLink Device according to manufacturer’s instructions. This driver requires  
that the DataLink device’s DTPCONFIG table has been configured prior to connection with a  
FieldServer. Consult the manufacturer’s information on connecting Carrier Device’s to CCN  
network.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 6 of 31  
4.  
Configuring the FieldServer as a Carrier DataLink Client  
It is not possible to configure communication with a DataLink device until familiar with the data  
available from the devices connected to the DataLink. The DataLink device does not provide a  
method for discovering the data tables and variables that are available in all the Carrier devices.  
In order to configure the Client it is necessary to know the names of the data tables available in  
the devices connected via the CCN network to the data link. A partial list of available tables is  
provided in Appendix A.1. If you know the table names and the variable names that you wish to  
poll then you have enough information to complete the configuration. If you have table names  
but do not know variable names then we provide a method of discovering the variable names.  
This method is discussed in chapter 6. If you do not have the table names then you will need to  
consult with the Carrier Corporation before proceeding.  
For a detailed discussion on FieldServer configuration, please refer to the FieldServer  
Configuration manual. The information that follows describes how to expand upon the factory  
defaults provided in the configuration files included with the FieldServer (See “.csv” sample files  
provided with the FieldServer).  
This section documents and describes the parameters necessary for configuring the FieldServer  
to communicate with a Carrier DataLink Server.  
The configuration file tells the FieldServer about its interfaces, and the routing of data required.  
In order to enable the FieldServer for Carrier DataLink communications, the driver independent  
FieldServer buffers need to be declared in the “Data Arrays” section, the destination device  
addresses need to be declared in the “Client Side Nodes” section, and the data required from  
the servers needs to be mapped in the “Client Side Map Descriptors” section. Details on how to  
do this can be found below.  
Note that in the tables, * indicates an optional parameter, with the bold legal value being the  
default.  
4.1.  
Data Arrays/Descriptors  
Section Title  
Data_Arrays  
Column Title  
Function  
Legal Values  
Up to 15 alphanumeric  
characters  
Data_Array_Name Provide name for Data Array  
FLOAT, BIT, UInt16, SInt16,  
Packed_Bit, Byte,  
Packed_Byte, Swapped_Byte  
Provide data format. Each data  
Data_Format  
array can only take on one format.  
Number of Data Objects. Must be  
larger than the data storage area  
required for the data being placed in  
Data_Array_Length  
1-10,000  
this array.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 7 of 31  
Example  
// Data Arrays  
Data_Arrays  
Data_Array_Name,  
DA_AI_01,  
DA_AO_01,  
DA_DI_01,  
Data_Format,  
UInt16,  
UInt16,  
Bit,  
Data_Array_Length  
200  
200  
200  
200  
DA_DO_01,  
Bit,  
4.2.  
Client Side Connection Descriptions  
Section Title  
Connections  
Column Title  
Function  
Legal Values  
Specify which port the device is connected to the  
FieldServer  
Port  
P1-P8, R1-R21  
300, 600 , 1200,  
2400, 9600 (Vendor  
limitation)  
Baud*  
Specify baud rate  
None (Vendor  
Limitation)  
Parity*  
Specify parity.  
Data_Bits*  
Stop_Bits*  
Protocol  
8 (Vendor Limitation)  
1 (Vendor limitation)  
CarrrierDL  
Specify data bits  
Specify stop bits  
Specify protocol used  
None  
Handshaking* Specify hardware handshaking  
0-32000 seconds, 1  
second  
Poll _Delay*  
Time between internal polls  
When reading entire tables it is recommended that  
the timeout be set to between 15 and 30 seconds.  
Additional information is provided in Appendix A.5  
When reading entire tables it is recommended that  
the ic_timeout be set to approx 15.0 seconds.  
Additional information is provided in Appendix A.5  
0.1 to 60.0 seconds,  
2.0seconds  
Timeout*  
IC_Timeout*  
Example  
// Client Side Connections  
Connections  
Port, Baud, Parity, Data_bits, Stop_Bits, Protocol,  
Handshaking, Poll_Delay  
P8,  
9600, None,  
8
,
1
,
CarrierDL, None  
,
0.100s  
1
Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction  
manual for details of the ports available on specific hardware.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 8 of 31  
4.3.  
Section  
Title  
Nodes  
Client Side Node Descriptors  
Column  
Title  
Function  
Legal Values  
Up to 32  
Node_Name Provide name for node  
alphanumeric  
characters  
Modbus station address of physical server node.  
These correspond to the ‘devices’ configured in the  
DTPConfig. Thus the Node_ID is not the address of  
the final CCN device.  
Node_ID  
1-15  
The DataLink DTPConfig table maps a device number  
(1..15) to a bus number (0-239). Use the Node_ID to  
tell the driver which device to use.  
Protocol  
Port  
Specify protocol used  
Specify which port the device is connected to the  
FieldServer  
CarrierDL  
P1-P8, R1-R22  
Example  
// Client Side Nodes  
Nodes  
Node_Name,  
Node_ID,  
Protocol ,  
CarrierDL,  
Port  
P8  
FAN1  
4.4.  
4.4.1.  
,
1
,
Client Side Map Descriptors  
FieldServer Related Map Descriptor Parameters  
Column Title  
Function  
Legal Values  
Up to 32 alphanumeric  
characters  
One of the Data Array names  
from “Data Array” section  
above  
Map_Descriptor_Name Name of this Map Descriptor  
Name of Data Array where  
Data_Array_Name  
data is to be stored in the  
FieldServer  
Starting location in Data  
Array  
Function of Client Map  
Descriptor  
0 to maximum specified in  
“Data Array” section above  
Data_Array_Location  
Function  
RDBC, WRBC, WRBX  
2
Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction  
manual for details of the ports available on specific hardware.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 9 of 31  
4.4.2.  
Column  
Title  
Driver Related Map Descriptor Parameters  
Function  
Legal Values  
One of the node names  
specified in “Client Node  
Descriptor” above  
Node_Name Name of Node to fetch data from  
Data type. This parameter is not required  
except when defining Map Descriptors  
which write DOW (Day of Week) and  
Time value to the Carrier devices. When  
-
Data_Type  
a write Map Descriptor checks the data  
type it uses the information to convert the  
value extracted from the FieldServer’s  
Data Arrays into a suitable format for a  
write. Refer to Section 4.4.7.  
Occupancy_Time  
Occupancy_DOW  
Length of Map Descriptor. When reading  
a compete table, set the length to the  
maximum number of data values you  
want stored. Additional information on the  
length parameter is provided in Appendix  
A.5.  
Length  
1 – 1000  
Address  
This commonly used parameter is not required for this driver.  
The name of the table to be polled, e.g.  
Only ASCII characters are  
permitted.  
DISPLAY. Some system elements have  
multiple instances of the same table  
name. For example, the Terminal System  
Manager has 64 Temperature Zone  
configuration tables named TZONE1  
though TZONE64. These tables are  
accessed by using both the primary &  
secondary table names, e.g. ‘TZCONF  
TZONE1’  
When using the table  
Table_Name  
name parameter to specify  
a primary and secondary  
table, leave a single space  
between the two names.  
Only ASCII characters are  
permitted. Field names  
never contain spaces.  
They may not be longer  
than 10 characters long.  
If you wish to read the whole table, leave  
Field_Name* the field name blank or specify  
‘EVERYTHING’.  
Use the Ascii or AsciiLog format when you  
are discovering the variables contained in  
a table by reading a table. Refer to 1.1  
Ascii, AsciiLog, Values  
Store_As*  
4.4.3.  
Timing Parameters  
Column Title  
Scan_Interval  
Function  
Rate at which data is polled >0.1s  
Legal Values  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 10 of 31  
4.4.4.  
Map Descriptor Example 1 – Read a Table  
This example illustrates how to read the entire contents of a table called ‘DISPLAY’. The Map Descriptor is connected to a node  
using the node name and a node definition provides a connection to a port. Thus this Map Descriptor is connected to a port via its  
node. The FieldServer will use that port to send this poll which will be generated every 5 seconds.  
The value extracted from the response will be stored in the array called DA_DISPLAY. Ensure that it is suitable format for storing a  
number – FLOAT is suggested. The driver stores the value of the 1st element at offset 1; the 2nd element at offset 2… The number of  
table elements whose values have been successfully stored at is stored at offset zero.  
// Client Side Map Descriptors  
Map Descriptors  
Map_Descriptor_Name, Data_Array_Name, Data_Array_Offset, Function,  
Read_Table_Md DA_DISPLAY , rdbc  
Node_Name, Length,  
FAN01 100  
Scan_Interval, Table_Name, Field_Name  
5.0s DISPLAY , EVERYTHING  
,
0
,
,
,
,
,
The name of the  
table to be read.  
The driver  
generates a read  
poll continuously.  
Responses are stored in  
this data array. Table  
element x gets stored at  
offset x, where x is a non-  
zero integer.  
The length is set  
to a number big  
enough to contain  
all the table’s  
variables.  
The node name  
connects the Map  
Descriptor to a  
node definition.  
By using the keyword  
‘EVERYTHING’ you are  
telling the driver to read  
the whole table.  
Offset zero is used by the  
driver to report how many  
values were stored.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 13 of 31  
5.  
Configuring the FieldServer as a Carrier DataLink Server  
For a detailed discussion on FieldServer configuration, please refer to the FieldServer  
Instruction Manual. The information that follows describes how to expand upon the factory  
defaults provided in the configuration files included with the FieldServer (See “.csv” sample files  
provided with the FieldServer).  
This section documents and describes the parameters necessary for configuring the FieldServer  
to communicate with a Carrier DataLink Client.  
The FieldServer can be configured to emulate a Carrier DataLink Device. The use is able to  
define a variable number of data tables, allocating a table name a variable number of variables.  
The FieldServer may be polled and will respond like a DataLink device. Remote clients can  
force variable states by ending write variable commands.  
The FieldServer does not emulate any of the alarm buffer/history features of the DataLink  
Device.  
All variables may be read or written without restriction.  
The configuration file tells the FieldServer about its interfaces, and the routing of data required.  
In order to enable the FieldServer for Carrier DataLink communications, the driver independent  
FieldServer buffers need to be declared in the “Data Arrays” section, the FieldServer virtual  
node(s) needs to be declared in the “Server Side Nodes” section, and the data to be provided to  
the clients needs to be mapped in the “Server Side Map Descriptors” section. Details on how to  
do this can be found below.  
Note that in the tables, * indicates an optional parameter, with the bold legal value being the  
default.  
5.1.  
Server Side Connection Descriptors  
Section Title  
Connections  
Column Title  
Function  
Specify which port the device is  
connected to the FieldServer  
Legal Values  
P1-P8, R1-R23  
Port  
300, 600 , 1200, 2400, 9600  
(Vendor limitation)  
Baud*  
Specify baud rate  
None (Vendor limitation)  
Parity*  
Specify parity  
Data_Bits*  
8 (Vendor limitation)  
1 (Vendor limitation)  
Specify data bits  
Specify stop bits  
Stop_Bits*  
Protocol  
Specify protocol used  
CarrrierDL  
None  
Handshaking* Specify hardware handshaking  
3
Not all ports shown are necessarily supported by the hardware. Consult the appropriate Instruction  
manual for details of the ports available on specific hardware.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 14 of 31  
Example  
// Server Side Connections  
Connections  
Port, Baud, Parity, Data_bits, Stop_Bits,  
Protocol ,  
CarrierDL,  
Handshaking,  
None  
Poll_Delay  
0.100s  
P8, 9600, None , 8  
,
1
,
,
5.2.  
Section  
Server Side Nodes  
Title  
Nodes  
Column  
Title  
Function  
Legal Values  
Up to 32  
Node_Name Provide name for node  
alphanumeric  
characters  
Modbus station address of physical server node.  
These correspond to the ‘devices’ configured in the  
DTPConfig. Thus the Node_ID is not the address of  
the final CCN device.  
Node_ID  
1-15  
The DataLink DTPConfig table maps a device  
number (1...15) to a bus number (0-239). Use the  
Node_ID to tell the driver which device to use.  
Specify protocol used  
Protocol  
CarrierDL  
Example  
// Server Side Nodes  
Nodes  
Node_Name,  
Node_ID,  
Protocol ,  
CarrierDL,  
Port  
FAN1  
,
1
,
It is common to leave Server nodes  
unconnected to a port. This means that the  
FieldServer can respond with the node’s  
data irrespective of which port the request  
is received on.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 15 of 31  
5.3.  
Server Side Map Descriptors  
5.3.1.  
FieldServer Specific Map Descriptor Parameters  
Function Legal Values  
Up to 32 alphanumeric  
Column Title  
Map_Descriptor_Name Name of this Map Descriptor  
characters  
Name of Data Array where  
data is to be stored in the  
FieldServer  
One of the Data Array names  
from “Data Array” section  
above  
Data_Array_Name  
0 to maximum specified in  
“Data Array” section above  
Passive  
Data_Array_Location  
Function  
Starting location in Data Array  
Map Descriptor function  
5.3.2.  
Driver Specific Map Descriptor Parameters  
Column Title  
Function  
Legal Values  
One of the node  
names specified in  
“Server Node  
Node_Name  
Data_Type  
Length  
Name of Node to fetch data from  
Descriptor” above  
This commonly used parameter is not required for this driver.  
Length of Map Descriptor. When reading a  
compete table, set the length to the maximum  
1 – 1000  
number of data values to be stored. Refer to  
1.1.  
Address  
This commonly used parameter is not required for this driver.  
The name of the table to be polled, e.g.  
ASCII characters  
DISPLAY. Some system elements have  
only. When using  
multiple instances of the same table name,  
this parameter to  
e.g. the Terminal System Manager has 64  
specify a primary  
Table_Name  
Temperature Zone configuration tables  
and secondary table,  
named TZONE1 though TZONE64. These  
leave a single space  
tables are accessed by using both the  
between the two  
primary & secondary table names, e.g.  
names.  
‘TZCONF TZONE1’  
ASCII characters  
only. No spaces,  
This is the field/table variable pneumonic.  
maximum length 10  
Field_Name  
characters.  
Returned when a client does a table read. If  
Field_Description  
Field_Units  
ASCII string which  
units have no meaning for the variable then  
may contain spaces.  
leave this field blank or use a single dash.  
If the variable has a discrete state, use this  
parameter to define the word that describes  
the state when the variable’s value is 1.  
OR  
NUMERIC  
TIME  
STRING  
DOW  
On_String  
Use one of the keywords to tell the driver to  
Or any other ASCII  
send the value of the associated array  
string which may not  
elements as a number (keyword=NUMERIC), contain spaces.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Column Title  
Page 16 of 31  
Legal Values  
Function  
as a time value formatted as hh:mm  
(keyword=TIME) or as a string of bytes  
(keyword=STRING) or as an occupancy  
string (keyword=DOW).  
When using the string keyword the driver  
reads x consecutive array elements and  
treats them like ASCII character values in  
forming the response. X is defined by the  
length parameter.  
If the variable has a discrete state, use this  
parameter to define the word that describes  
the state when the variable’s value is zero. If  
you have used one of the above keywords,  
simply put a dash in this field.  
An ASCII string  
which may not  
contain spaces.  
Off_String  
Always set the length to 1 unless you use the  
key word ‘STRING’ as the On_String  
parameter.  
Length  
1
5.3.3.  
Timing Parameters  
Legal  
Values  
Column Title  
Function  
Specifies time server side waits before responding  
to client that node is offline on FieldServer client  
side.  
Scada_Hold_Timeout  
>1.0s  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 18 of 31  
5.4.  
Driver Limitations and Exclusions  
As a client:  
The Carrier DataLink driver is not capable of polling for alarm data. (The RA and AV  
functions are not implemented).  
The Carrier DataLink driver dos not validate table or variable names.  
The Carrier DataLink driver does not support the Read Table command with the /C or /N  
options.  
The Carrier DataLink driver records a timeout if the DataLink device does not provide the  
‘?’ prompt within the user-configurable timeout period.  
Write-thru’s are not supported. The reason for this is that the driver read a composite  
data set and the client side Map Descriptors do not contain enough information to format  
a write.  
As a server:  
The Carrier DataLink driver is not capable of serving alarm data. (RA and AV polls  
produce an error response)  
The driver cannot set a discrete variable’s state unless it is set a value of one or zero.  
The driver server does not understand write table or write variable requests where the  
requested state is a word like ON or OFF.  
The Carrier DataLink driver does not validate values or states, it simply stores the  
values.  
All variables are may be read and written without limitation. The driver has not  
implemented the Courier notion of Force Levels.  
There is no command buffer. One command can be processed at a time.  
The driver responds to all Read Table commands as if the /Y option was used. The  
driver does not support the /C or /N options.  
The Carrier DataLink driver does not support the control character commands CTRL-  
C/S/Q  
General  
The Carrier DataLink driver is not capable of configuring the DataLink device. Software  
provided by the Carrier Corporation is required to do this. The DataLink device requires  
configuration, so that connects to the appropriate CCN devices on the CCN  
communications network.  
The driver cannot be configured to act as what the Carrier Corporation identify as an  
‘Alarm Acknowledger’.  
If the total length of the response from a read table query is more than 3000 bytes long,  
the driver will produce an error.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 19 of 31  
Appendix A. Advanced Topics  
Appendix A.1. Table Names  
The following list of table names is provided as a reference. Carrier may add tables and  
new devices may become available.  
Equipment Type  
Table Name  
STATUS01  
STATUS02  
STATUS03  
STATUS04  
SETPOINT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
OCCDEFCS  
OCCPC03S  
COMPRESS  
CVC_PSWD  
HEAT_EX  
Equipment Type  
Table Name  
OPTIONS  
SETPOINT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
ECONOMZR  
GENERAL  
TSTAT  
17/19EX CHILLER:  
48/50HG CENTURION  
ROOFTOP:  
SETPOINT  
OccDefcS  
OCCPC01S  
AIR MANAGER AHU  
CONTROLLER:  
DISPLAY  
SETPOINT  
BASESYS  
BYPASS  
ISM_STAT  
MAINSTAT  
POWER  
POINTS1  
CHILLERVISOR:  
STARTUP  
SETPOINT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
OCCDEFCS  
OCCPC03S  
A_UNIT  
POINTS2  
23XL CHILLER:  
SETPOINT  
OCCDEFCS  
OCCPC01S  
POINTS  
SETPOINT  
OCCDEFCS  
OCCPC64S  
DISPLAY  
COMFORTID VAV  
TERMINAL CONTROL:  
CIRCADIO  
CIRCA_AN  
OPTIONS  
SETPOINT  
OccDefcS  
COMFORTID FAN  
COIL CONTROLLER:  
SETPOINT  
OCCDEFCS  
OCCPC64S  
FSMSTAT1  
FSMSTAT2  
FSMSTPT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
HWP01-32  
HWP33-64  
SWP65-96  
SETPOINT  
SETPT01  
30GTNHW CHILLER:  
OCCPC01S  
A_UNIT  
FLOTRONIC SYSTEM  
MANAGER:  
CIRCADIO  
CIRCA_AN  
CIRCBDIO  
(some units)  
CIRCB_AN  
(some units)  
OPTIONS  
SETPOINT  
BASEUNIT  
DXCOOL  
30RA AQUASNAP  
CHILLER:  
50 VPAC:  
39N AIR HANDLER:  
SETPOINT  
SETPT02  
ELECHEAT  
SETPOINT  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 20 of 31  
Equipment Type  
Table Name  
SETPT03  
SETPOINT  
SETPT04  
SETPOINT  
SETPT05  
SETPOINT  
SETPT06  
SETPOINT  
SETPT07  
SETPOINT  
SETPT08  
Equipment Type  
Table Name  
STATUS03  
STATUS04  
STATUS05  
STATUS06  
SETPOINT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
STATUS01  
STATUS02  
STATUS03  
STATUS04  
STATUS05  
STATUS06  
SETPOINT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
POINTS  
SETPOINT  
OCCDEFCS  
OCCPC64S  
CV_TSTAT  
DXCOOL  
STATUS01  
STATUS02  
SETPOINT  
OccDefcS  
OCCPC01S  
CV_TSTAT  
STATUS01  
SETPOINT  
OCCDEFCS  
OCCPC64S  
BYPSSTAT  
SETPOINT  
ZONESTAT  
SETPOINT  
OccDefcS  
OCCPC01S  
HWP01-32  
HWP33-64  
SWP65-96  
SETPOINT  
SETPT01  
OCCPCxxC  
OCCPC01  
COMPRESS  
CVC_PSWD  
HEAT_EX  
ISM_STAT  
MAINSTAT  
POWER  
STARTUP  
SETPOINT  
OCCDEFCS  
OCCPC01S  
OCCDEFCS  
OCCPC02S  
OCCDEFCS  
OCCPC03S  
A_UNIT  
CIRCADIO  
CIRCA_AN  
CIRCBDIO  
CIRCB_AN  
OPTIONS  
SETPOINT  
OccDefcS  
OCCPC01S  
A_UNIT  
CIRCADIO  
CIRCA_AN  
CIRCBDIO  
CIRCB_AN  
OPTIONS  
SETPOINT  
OccDefcS  
OCCPC01S  
ZONESTAT  
SETPOINT  
OccDefcS  
OCCPC01S  
DISPLAY  
48/50M SERIES  
ROOFTOP:  
19XR PIC II CHILLER:  
COMFORTID FAN  
TERMINAL CONTROL:  
CONQUEST  
ROOFTOP:  
30GTN CHILLER:  
PREMIERLINK  
ROOFTOP  
CONTROLLER:  
VVT BYPASS  
CONTROLLER:  
VVT SLAVE STAT:  
30GXNHXA CHILLER:  
33CS VVT MONITOR:  
COMFORT  
CONTROLLER  
6400/1600:  
OCCPCxxC  
OCCPC01  
40UV UNIT  
VENTILATOR  
48/50F SERIES  
ROOFTOP:  
SETPOINT  
STATUS01  
STATUS02  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 23 of 31  
Appendix A.3. Map Descriptor Length Explained  
The Length parameter is specified as part of the Map Descriptor.  
Appendix A.3.1.  
Client Reads a Table:  
The length determines the number of table variables whose values are to be stored  
when the response is received. If you do not know the length of the table in advance,  
set the length to a large number (e.g. 100). If the table contains more elements than the  
number defined in the length parameter, the additional data will be discarded.  
Appendix A.3.2.  
Client reads a variable:  
Response to a variable read takes many forms. The ‘value’ returned can be a number, a  
state (like ON), a time or some other string. To store a number or the time set the length  
to 1. When a state or string is returned, the driver looks it up in a table of state words. If  
it makes a match then it returns the value that has been associated with the state word,  
(e.g. ON = 1, OFF = 0). If it cannot make a match, it stores the string byte for byte in the  
data array. The number of bytes stored is determined by the length parameter. Thus, if  
the length is 1 and the string is ‘INTERRUPTED’ then the driver will store the ‘I’ in the  
data array. If the length was two, then the driver would use two consecutive locations  
and store ‘I’ and ‘N’.  
Appendix A.3.3.  
Client writes a variable:  
Always set the length to 1  
Appendix A.3.4.  
Server:  
The length parameter is used when the server returns a value that is a string. The  
length is used to tell the driver how many characters to extract from consecutive array  
location to form the response string. When the server returns a value that is a number,  
state or time the length should always be 1.  
Appendix A.4. How the Client stores the states/values of the Table Variables.  
Appendix A.4.1.  
Discrete States  
When a Carrier DataLink device reports the state of a table variable which has a discrete  
state, it reports the state as a keyword like on/off. This driver has to convert the  
keywords to numbers as most other remote devices are interested in the state as a  
numeric value of 1 or 0.  
The driver is programmed to recognize certain keywords. A list is provided below. The  
driver is also capable of allowing the user to add to the table of predefined keywords by  
specifying additional information in the configuration file.  
State Word  
CLEAN  
DIRTY  
HEAT  
COOL  
ON  
Value  
State Word  
ALERT  
EMSTOP  
ENABLE  
Service  
Value  
1
0
1
0
1
2
0
1
0
1
OFF-local  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 24 of 31  
State Word  
OFF  
OPEN  
CLOSE  
CLOSED  
ABNORMAL  
NORMAL  
ALARM  
STOP  
Value  
State Word  
OFF-CCN  
OFF-time  
Emergency  
ON-local  
ON-CCN  
ON-time  
Redline  
Value  
0
1
0
0
1
0
1
0
1
1
0
2
3
4
5
6
7
1
2
0
0
1
Shed  
DSABLE  
LOCAL  
START  
YES  
NO  
REMOTE  
If the driver doesn’t recognize the state word it stores the characters of the state word as  
decimal values based on their ASCII value. The number of characters stored is  
dependent on the length parameter.  
For example, say the driver responds, reporting a variable to be a state ‘INCREDIBLE’.  
If the length parameter of the polling map descriptor is 1 then the driver stores a value of  
73 (An uppercase ‘I’ is the seventy third character in the ASCII alphabet.). If the length  
was 2 then the driver would also store the value 78 in the next array. The driver will store  
a maximum of 100 characters. The driver recognizes discrete state words by checking  
the 1st character of the value field. If it is a non-digit then it is regarded as a state word.  
Appendix A.4.2.  
Extending the List of Discrete State Words  
You can extend the list of state words the driver recognizes by modifying the  
configuration file.  
The following example adds three state words. If a device reports the state of the  
variable as LIGHT then the driver will store the value of 1, if on the other hand the  
state is reported as DARK then the driver will store the value zero.  
State Words. The  
name will be  
stripped of all  
spaces between  
the last character  
and the comma.  
Normally the values  
Keyword  
starts a new  
section of  
the CSV file.  
will be 1 or zero for  
the on/off states but  
the driver does not  
restrict the value.  
Protocol must be  
defined on every  
line.  
Driver_Table  
Carrier_Attr_State_Name,  
Carrier_Attr_State_Value,  
Protocol  
LIGHT  
DARK  
,
,
1
0
,
,
CarrierDL  
CarrierDL  
You can use this method to change the values of any of the driver’s default state words  
by duplicating the word and specifying a new value in the configuration file.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Appendix A.4.3.  
Page 25 of 31  
Time Values  
If the driver receives a variable value reported in the format hh:mm then the driver stores  
a number obtained by multiplying the hours by 60 and adding the minutes. The driver  
recognizes a time value by checking the 3rd character for a colon and checking that the  
1st character is a digit.  
Value_Stored = hh * 60 + mm  
Eg. 5:30pm is reported as 17:20 and is stored as 17*60 + 20 = 1040.  
Appendix A.4.4.  
Numeric Values  
The driver recognizes numeric values by checking the first character of the value field. If  
it is a digit then the field is treated as a number.  
Appendix A.4.5.  
Occupancy Strings / Values  
If the value returned for a variable is 8 characters long and each of the characters is a  
one or a zero then the driver regards this as an occupancy string and converts it to a  
binary coded decimal value and stores this value.  
Eg: 00101010 = 42 decimal  
Appendix A.5. Timing Considerations  
Reading a whole table can take several seconds depending on the table length. In addition  
the response from the Carrier device can have small pauses after each line of response.  
Thus, if you use the default timeout and IC_Timeout settings the communications may fail  
when either one of the pauses exceeds the IC_Timeout setting or when the whole response  
hasn’t been received by the time the timeout setting has elapsed.  
For this reason it is recommended that the timeout be set to a value between 15 and 30  
seconds and the IC_Timeout be set to a value between 7 and 15 seconds. Before setting  
either of these to the maximum consider that the in the event of a real communications  
failure, this set amount of time must elapse before the driver recognizes the timeout and  
reports the node offline. Thus, it is best to start with a smaller value and increase it until  
reliable communications have been achieved with the timeout settings.  
The timeout can be set for the Map Descriptor, the node or the connection. This is more  
fully explained in the FieldServer Configuration Manual. In summary, if you wish to apply a  
single timeout to all messages to a device then set the timeout for the connection. If you  
wish to override the connection timeout settings for a particular node the set the timeout for  
that node too and if you wish to override the settings for a particular Map Descriptor then set  
the timeout for that Map Descriptor.  
The example below illustrates how to set the timeout parameters at the connection level.  
// Client Side Connections  
Connections  
Port, Baud, Parity, Data_bits, Stop_Bits, Protocol ,  
Handshaking, Poll_Delay, Timeou,t, IC_Timeout  
0.100s 30.0s , 15.0s  
P8, 9600, None, CarrierDL, None  
8
,
1
,
,
,
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 26 of 31  
Appendix B. Carrier DataLink Device Error Response  
The following notes are provided from the protocol specification.  
Message  
Explanation  
Action  
Check the spelling of the  
command and verify that it  
contains the required  
parameters.  
#1 Invalid  
Command  
The last command sent to the DataLink  
device is not recognized.  
Check the spelling of the table  
name(s). If using a WV or RV  
command; verify that the table  
contains the specified  
variables.  
#2 Invalid or Non-  
Existent Table  
The specified table does not exist in the  
specified element.  
A Communication error has occurred  
due to other activity on the CCN  
communication bus, a system element  
failure, or an incorrect address. The  
command will not be executed.  
#3 Level II  
Communications  
Error  
Verify the COMM2 connector  
is not disconnected and retype  
the command.  
Verify that the correct bus and  
The specified system element’s bus and element number have been  
#6 Device Not  
Configured  
entered in the DTP-CONFG  
table corresponding to the  
device number.  
the element number were not found in  
the DTP-CONFG table.  
Check the spelling of the  
variable name and verify that  
the CCN variable exists in the  
specified system element.  
Verify the format of the data.  
#7 Variable Does  
Not Exist  
The variable does not exist in the  
specified table.  
#8 Invalid Data  
The data was in an incorrect format.  
An attempt was made to read or write to  
a table or variable type that is not  
supported by the DataLink device.  
The value that was typed is outside the  
#9 Access  
Restricted  
Check variable.  
#10 Limits  
Exceeded  
Verify the limits and adjust the  
specified variable’s upper or lower limits force value.  
Reissue the command at later  
time or adjust the alarm  
priority level.  
#11 Alarms Not  
Available  
There are no alarms currently in the  
alarm buffer.  
The CCN system element does not  
allow write access to the specified  
variable.  
#12 Cannot Force  
Variable  
Choose different variable.  
Check the spelling of the point  
(variable) name and verify that  
the point name exists in the  
specified system element.  
Retype the command after  
checking the force priority and  
after verifying that the correct  
bus and element number is  
The 8-character point (variable) name  
used in the RT or WT command does  
not exist.  
#13 Parameter Not  
Found  
The command was accepted but not  
understood by the specified system  
element, an attempt was made to write  
to or read a variable with a higher force  
#14 Level II  
Communications  
NACK  
level, or an attempt was made to write or entered in the DTP-CONFG  
read from a UT203 controller. table.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 27 of 31  
Appendix C. Driver Notes  
Appendix C.1. Driver Stats  
The driver reports statistics according to the FieldServer standards. The following notes  
describe some aspects of standard statistic reporting which are peculiar to this driver.  
All errors responses from the Carrier DataLink device are recorded as a PROCOL ERROR,  
In addition to the standard FieldServer communication statistics described above and in the  
FieldServer User’s Manual, this driver can also expose some driver statistics by writing data  
to a data array. A special Map Descriptor is required. The driver recognizes the Map  
Descriptor by its name which must be "Carrier-stats”.  
The following example shows how this special Map Descriptor can be configured. You can  
copy this section of text directly into your CSV file.  
Nodes  
Node_Name ,  
Carr_stats ,  
Station ,  
Protocol  
CarrierDL  
1
,
Data_Arrays  
Data_Array_Name ,  
DA_CARRIER_STATS ,  
Data_Format,  
Data_Array_Length  
2000  
UINT32  
,
Map_Descriptors  
Map_Descriptor_Name,  
Carrier-Stats,  
Data_Array_Name ,  
DA_CARRIER_STATS 0,  
Data_Array_Offset  
Function Node_Name ,  
Length  
500  
passive,  
Carr_stats,  
When the driver sees this Map Descriptor it uses the data array DA_CARRIER_STATS (in this  
example) to store driver specific statistics. Only one of these Map Descriptors may be  
specified per FieldServer.  
The driver stores the following data. The location in the data array is obtained by  
multiplying the port number by 50 and then using the location offset indicated in the table  
below.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
OFFSET  
Page 28 of 31  
DESCRIPTION  
0
1
2
3
4
5
6
Number of Read Table messages sent  
Number of Read Variable messages sent  
Number of Write Table messages sent  
Number of Write Var Messages sent  
Number of bytes sent by client driver  
Number of messages sent by client  
Number of response messages received by client  
Number of times client tries write with alternate format because original  
method failed  
7
9
Most recent response error  
8
Number of times client receives an error response  
Carrier Error: #1 Invalid Command"  
Carrier Error: #2 Invalid or Non-Existent Table"  
Carrier Error: #3 Level II communications Error"  
Carrier Error: #4 Error not defined"  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
Carrier Error: #5 Error not defined"  
Carrier Error: #6 Device Not Configured"  
Carrier Error: #7 Variable Does not Exist"  
Carrier Error: #8 Invalid Data"  
Carrier Error: #9 Access Restricted"  
Carrier Error: #10 Limits Exceeded"  
Carrier Error: #11 Alarms not Available"  
Carrier Error: #12 Cannot Force Variable"  
Carrier Error: #13 Parameter Not Found"  
Carrier Error: #14 Level II Communications NACK"  
Some other error  
Number of response bytes received by client  
26  
Number of times client has timeout out waiting for (response) prompt  
When set then the server sends response whose var names have leading  
spaces. This is used for QAA testing and diagnostic purposes only.  
Customers should never set this value.  
27  
28  
29  
30  
31  
Number of times client cannot parse / recognize the value sting in a response  
Number of times the server had to store a time greater than 24:00  
Number of times the client sent a message with a time greater than 24:00  
Number of times the client sent a message to a probable occupancy table  
without the correct data types  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 29 of 31  
Appendix D. Driver Error Messages  
The driver reports information and errors in the form of messages printed to the error log. Those  
messages marked with a * are only printed once even if they occur repeatedly.  
Error Message  
Explanation  
Carrier:#1 FYI. The  
The length of the Map Descriptor used to expose driver  
MapDesc called <%s> is too statistics is too short. Set to at least 1000. This message may  
short  
be ignored§.  
Carrier:#2 FYI. You could  
have used a MapDesc called This message is a prompt and may be ignored. Read  
<%s> to expose diagnostic  
info.  
Appendix C.1 for more information.  
Carrier:#3 Err. Illegal  
Node_ID=%d Valid=1..15  
Carrier:#4 FYI. Address has  
no meaning. Best set to 1  
MapDesc=<%s>  
Valid node numbers are in the range 1 to 15 inclusive. Read  
sections 4.3 or 5.3 for more information. §  
You can ignore this message. The address parameter has no  
meaning in the configuration of this driver. Remove the  
parameter from the configuration or set its value to 1§  
Carrier:#5 Err. For write, set  
length to 1. MapDesc=<%s>  
Carrier:#6 FYI. Field Name  
Blank. Assumed  
'EVERYTHING'.  
MapDesc=<%s>  
If the Field_Name parameter is left unspecified then the driver  
assumes you intend reading the whole table by filling in the  
Field_Name with the keyword EVERYTHING. Suppress this  
message by specifying the Field_Name .§  
Every Map Descriptor for this driver requires that you specify a  
table name. Section 4.4.2 and Appendix A.1 provide additional  
information. §  
Carrier:#7 Err. Table name  
required. MapDesc=<%s>  
Carrier:#8 Err. Length  
required. MapDesc=<%s>  
The length parameter must be set in the configuration file to a  
value greater than zero. Refer to Appendix A.3.§  
You have specified a discrete state word in the configuration  
file which is a duplicate of one already in the list. The driver  
uses the new value, thus changing the values for the driver’s  
default discrete state words. You can ignore this message.  
The driver has limited space to store discrete state keywords  
added in the configuration file. The maximum is 150 words  
including the driver’s defaults. Remove some of the keywords  
you have added to the configuration file. §  
Carr:#9 FYI. Duplicate  
state=<%s>. Value has been  
updated from=%d to=%d  
Carr:#10 Err. No space.  
Driver rejects value  
state=<%s> value=%d  
You can ignore this message; it is for information only. Each  
time a new discrete state word is added to the driver from the  
configuration file, the driver reports the new word and its value.  
The read table command resulted in more variables being  
returned than you have reserved space for (with the length  
parameter). Increase the length parameter§.  
Carr:#11 FYI. User added  
value state=<%s> value=%d  
Carr:#12 Err. Length too  
short to store all. MD=<%s>  
Carrier:#13 FYI. Diagnostic  
send error #1 response.  
Carrier:#14 FYI. Diagnostic  
cancelled slave response  
These messages are for FieldServer engineers. If printed in  
the error log please call FieldServer support and report the  
message.  
§ Correct the error by editing the configuration CSV file, downloading the corrected file to the FieldServer  
and then resetting the FieldServer.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 30 of 31  
Error Message  
Explanation  
Carrier:#15 Err. Alarm  
commands not supported.  
Carrier:#16 Err. Alarm  
commands not supported.  
The server does not support alarm functions. Polls beginning  
AV or RA produce these errors. Re-configure your client not to  
request this information. §  
On the line immediately following this error the driver reports  
the response that generated the error. The driver will store a  
value that is the ASCII code for the first character of the  
unrecognized word. Add a new discrete state word to the .CSV  
file as described in Appendix A.4. §  
Carr:#17 Err. MD=<%s>  
discrete state word not  
recognized.  
This message may be ignored if your communications are  
operating reliably. Read Appendix A.5 for additional information  
on timing considerations. The message is printed when the  
driver detects that the configuration requires that a whole table  
be read and the timeout value is set below the recommended  
minimum of 15s for this operation.  
CarrDL:#18 FYI. Timeout  
probably too short. Read  
Manual.  
This error message should only be produced by FST’s QA  
testing procedure. If you see this error, call Tech Support after  
taking a log. Instructions for taking a log may be found in the  
Trouble Shooting Guide.  
CarrDL:#19 Err. Diagnostic.  
Call Support.  
The message is printed once and suppressed for subsequent  
occurrences. The message is printed when writing a time to a  
Carrier Device which is invalid as it is greater than 23:59.  
Check the value in the Data Array being used for the write. It’s  
possible an upstream device sent an invalid value. The driver  
sends the message with the invalid time and it’s up to the  
Carrier device to reject the setting.  
CarrDL:#20* FYI. Invalid  
Time(%02d:%02d) being  
written. MD=%s  
The message is printed once and suppressed for subsequent  
occurrences. The message is printed when the Server is  
required to store an invalid time (>23.59). Check the value in  
the Data Array being used for the write. The data is stored  
despite the warning.  
CarrDL:#21* FYI. Invalid  
Time(%02d:%02d) being  
stored. MD=%s  
These errors occur when communications are operating  
correctly but the CarrDL device cannot respond to the poll.  
The reason error is reported in the driver stats (See Appendix  
C.1) Stat #9, reports the error number of the most recent error  
reported. The message is printed once and then suppressed.  
These errors are most commonly produced when a table  
name/ variable name does not exist or is mis-spelled  
DOW and times require that the Data_Type be specified when  
writing to enable the Driver to convert the value extracted from  
the Data Array for formatting in the write message. This error  
is printed if the table name or the field name contain the sub-  
string “OCC”, the function is a write, and a Data_Type has not  
been specified. In most cases the write will be rejected by the  
Carrier device or the value may not be what you expect. Refer  
to Section 4.4.7 for more information.  
CarrDL:#23* Err. CarrDL  
device reported errors.  
Check exposed stats 8-23.  
CarrDL:#22* FYI. Read  
notes for #22 in Manual.  
MD=%s  
§ Correct the error by editing the configuration CSV file, downloading the corrected file to the FieldServer  
and then resetting the FieldServer.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FS-8700-82 Carrier DataLink  
Page 31 of 31  
THIS PAGE INTENTIONALLY LEFT BLANK  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldserver.com  
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clover Electronics DVR LCD221616 User Manual
Conair Hair Dryer S7FXR User Manual
Corega Headphones BTHS02 User Manual
Crown Audio Stereo Amplifier XTi 6000 User Manual
Dukane Power Supply 403 573 02 User Manual
Dukane Projector 8978W User Manual
Euro Pro Blender EP96W User Manual
Fender Guitar 19479 User Manual
Frigidaire Refrigerator LGHC2342LF3 User Manual
GE Washer GCRH410 User Manual