Design Information  
CONTENTS  
Design Information  
Installation Instructions  
Product Dimensions ......................................................................3  
Duct Cover Accessories ..............................................................4  
Product Clearances ......................................................................4  
Step 1, Construct Ceiling Support ......................................10–12  
Step 2, Mount Template..............................................................13  
Step 3, Size and Install Ductwork ............................................13  
Step 4, Install Support Frame and Duct Covers ....................14  
Step 5, Install Duct Transition and Damper ..........................15  
Step 6, Install Hood to Support ................................................15  
Step 7, Connect Duct ................................................................15  
Step 8, Connect Electrical..........................................................16  
Step 9, Install the Motor ............................................................16  
Step 10, Slide Duct Cover Down ..............................................17  
Step 11, Install Filters..................................................................17  
Step 12, Install Rods....................................................................17  
Step 13, Install Supplied Duct Cover, Top Cover....................18  
Step 14, Finalize Installation ......................................................18  
Step 15, Installation Checklist ..................................................19  
Advance Planning  
Ductwork Planning ......................................................................5  
Ceiling Framing for Support ........................................................5  
Accessory Frames and Duct Covers ........................................5  
Power Supply ................................................................................5  
Installation Height ........................................................................6  
Duct Fittings .................................................................................. 7  
Installation Preparation  
Tools and Materials Required ....................................................8  
Remove the Packaging ................................................................8  
Parts, Hardware, Accessory Packages ..................................9  
42” HOOD DIMENSIONS  
54” HOOD DIMENSIONS  
Model ZV54I  
Model ZV42I  
14”  
16”  
25-3/4”  
33”  
20”  
24”  
31-3/4”  
3/
36-1/4”  
42
54”  
Supplied duct covers dimensions: 16"W x 12"D x 9"H  
Supplied duct covers dimensions: 20-1/4"W x 12"D x 5"H  
These vent hoods are supplied with a support frame and  
decorative duct cover for ceiling heights of 7’11" to 8’5".  
The hood installation height is determined by the ceiling  
height. Accessories are available to reach ceiling  
heights from 8’6" to 10’4".  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design Information  
PRODUCT CLEARANCES  
DUCT COVER ACCESSORIES  
*Height  
to Ceiling  
20" For ZV42I  
24" For ZV54I  
30" Min.  
36" Max.  
36" Min.  
ZV42I  
* 9" for ceiling heights 7’11" to 8’5" using the supplied  
support frame and duct cover.  
Order ZX42DC10 for ceiling heights of 8"6" to 10’4".  
These vent hoods must be installed 30" min. to 36" max.  
above the cooking surface. Exact installation height is  
determined by ceiling height. The cooking surface  
should be at least 36” above the floor.  
ZV54I  
* 5" for ceiling heights 7’11" to 8’5" using the supplied  
support frame and duct cover.  
Order ZX54DC10 for ceiling heights of 8"6" to 10’4".  
IMPORTANT: Clearances may vary due to type of  
cooking product and local codes. Check with local  
inspectors to be sure standard is applicable.  
• When installing these Island Hoods above a  
Monogram Professional Range or Cooktop,  
installation clearance must be at least 30".  
These accessories include telescoping support  
frames and decorative covers. Order the accessory  
for your model at the same time as the vent hood and  
have on site before installation begins.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advance Planning  
ADVANCE PLANNING  
POWER SUPPLY  
Ductwork Planning  
IMPORTANT - (Please read carefully)  
• These vent hoods are equipped for 10” round  
ductwork.  
WARNING:  
MUST BE PROPERLY GROUNDED.  
• Determine the exact location of the vent hood.  
• Plan the route for venting exhaust to the outdoors.  
• Use the shortest and straightest duct route possible.  
For satisfactory performance, duct run should not  
exceed 150 ft. equivalent length for any duct  
configurations.  
• Refer to “Duct Fittings” chart to compute the  
maximum permissible length for duct runs to the  
outdoors.  
FOR PERSONAL SAFETY, THIS APPLIANCE  
ATTENTION –  
POUR DES  
RAISONS DE SÉCURITÉ, CET APPAREIL  
DOIT ÊTRE CORRECTEMENT MIS À LA TERRE.  
Remove house fuse or open circuit breaker before  
beginning installation.  
• Use rigid metal ductwork only.  
• Install a roof cap with damper at the exterior opening.  
Order the cap and any transitions needed in advance.  
Do not use an extension cord or adapter plug with  
this appliance. Follow National Electrical Code or  
prevailing local codes and ordinances.  
Ceiling Framing for Adequate Support  
• These vent hoods are heavy. Adequate structural  
support must be provided. The ceiling structure must  
be capable of supporting the weight of the hood and  
any inadvertent user contact loads (approximately 300  
pounds). The hood support frame will be supported by  
2 x 4 cross framing.  
Electrical Supply  
This vent hood must be supplied with 120V, 60Hz,  
and connected to an individual, properly grounded  
branch circuit, and protected by a 15 or 20 amp  
circuit breaker or time delay fuse.  
• Wiring must be 2 wire with ground.  
• If the electrical supply does not meet the above  
requirements, call a licensed electrician before  
proceeding.  
• Route house wiring in the ceiling, as close to the  
installation location as possible. Allow additional  
length from ceiling joists to reach the junction box  
on the bottom of the hood support frame.  
• Connect the wiring to the house wiring in accordance  
with local codes.  
Accessory Frames and Duct Covers  
• All models are shipped with a support frame and duct  
covers for ceilings heights of 7’11" to 8’5".  
• Optional accessories include telescoping support  
frames and duct covers to reach 8’6” and up to  
10’4” ceiling heights.  
• Optional accessories must be ordered with the hood  
and be on site before final framing and wall finishing.  
Grounding Instructions  
The grounding conductor must be connected to  
a ground metal, permanent wiring system, or an  
equipment-grounding terminal or lead on the hood.  
Mounting the hood without a support frame  
The distance between the cooking surface and the  
bottom of the hood must be 30" to 36". In situations  
where the ceiling is low, the hoods may be secured  
directly to the ceiling without the supplied frame.  
Use the bottom of the supplied support frame as a  
template to locate the mounting holes in the top of the  
hood. Use shims on the ceiling joists or cross framing  
in the mounting hole locations. This will allow the  
mounting screws to engage the recessed keyhole  
slots in the top of the hood. See Step 2.  
WARNING:  
The improper  
connection of equipment-grounding  
conductor can result in a risk of electric shock. Check  
with a qualified electrician or service representative if  
you are in doubt whether the appliance is properly  
grounded.  
AVERTISSEMENT  
Le mauvais branchement du fil de mise  
à la terre peut causer un choc électrique. En cas  
de doute, consulter un électricien qualifié ou un  
technicien pour déterminer si l’appareil est à la terre.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advance Planning  
Model ZV42I  
Chimney Length at  
INSTALLATION HEIGHT REQUIREMENTS  
Actual  
Ceiling  
Duct  
• These vent hoods must be installed 30" min. and 36" max.  
above the cooking surface – regardless of the ceiling  
height. Therefore, installation height of the hood depends  
on the exact ceiling height of the kitchen.  
Hood Installation Height  
Cover  
Height 30" 31" 32" 33" 34" 35" 36" Kit  
10’4"  
10’3"  
10’2"  
10’1"  
10’  
9’11"  
9’10"  
9’9"  
9’8"  
9’7"  
9’6"  
9’5"  
9’4"  
9’3"  
9’2"  
9’1"  
9’  
8’11"  
8’10"  
8’9"  
8’8"  
8’7"  
8’6"  
8’5"  
8’4"  
8’3"  
8’2"  
8’1"  
8’  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
33 32  
32 31  
31 30  
30 29  
29 28  
28 27  
27 26  
26 25  
25 24  
24 23  
23 22  
22 21  
21 20  
20 19  
19 18  
18 17  
17 16  
16 15  
15  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
Order  
36  
35  
34  
33  
32  
31  
30  
29  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
ZX42DC10  
Use Long  
Support  
and  
• Accessories are available for ceiling heights 8’6" and up  
to 10’4".  
Example: Hood installation height with 8 ft. ceilings.  
Duct Cover  
8 ft. Ceiling  
8 ft. Ceiling  
5"  
9"  
Supplied  
Duct  
Supplied  
Duct  
Order  
Cover  
Cover  
ZX42DC10  
Use Short  
Support  
and  
31"  
31"  
ZV54I  
Duct Cover  
ZV42I  
• Both models are shipped with a support frame and duct  
cover for 7’11" to 8’5" ceilings.  
• If the ceiling height is 7’11", the installation height above  
the cooking surface will be 30".  
• If the ceiling height is 8’5", the hood installation height  
will be 36".  
9
9
Use  
9
Supplied  
Support  
and  
DETERMINE INSTALLATION HEIGHT  
1. Measure the exact ceiling height.  
2. Review the chart to determine the range of hood  
installation heights that can be accomplished  
with or without an accessory kit.  
9
9
9
Duct Cover  
7’11"  
9
Model ZV54I  
Actual  
Ceiling  
Chimney Length at  
Duct  
Cover  
Duct Cover  
Hood Installation Height  
Height 30" 31" 32" 33" 34" 35" 36" Kit  
10’4"  
10’3"  
10’2"  
10’1"  
10’  
9’11"  
9’10"  
9’9"  
9’8"  
9’7"  
9’6"  
9’5"  
9’4"  
9’3"  
9’2"  
9’1"  
9’  
8’11"  
8’10"  
8’9"  
8’8"  
8’7"  
8’6"  
8’5"  
8’4"  
8’3"  
8’2"  
8’1"  
8’  
28  
28 27  
27 26  
26 25  
25 24  
24 23  
23 22  
22 21  
21 20  
20 19  
19 18  
18 17  
17 16  
16 15  
15 14  
14 13  
13 12  
12  
Order  
20" for ZV42I  
24" for ZV54I  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
ZX54DC10  
Use Long  
Support  
and  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
28  
27  
26  
25  
24  
23  
22  
21  
20  
19  
18  
17  
16  
15  
14  
13  
12  
28  
28 27  
27 26  
26 25  
25 24  
24 23  
23 22  
22 21  
21 20  
20 19  
19 18  
18 17  
17 16  
16 15  
15 14  
14 13  
13 12  
12  
Ceiling  
Height  
Duct Cover  
30" Min. and 36" Max.  
Order  
ZX54DC10  
Use Short  
Support  
and  
36"  
to  
Countertop  
Duct Cover  
ACCESSORIES  
ZX42DC10 – Optional Accessory for ZV42I.  
ZX54DC10 – Optional Accessory for ZV54I.  
Accessories for ceiling heights of 8’6" to 10’4".  
Includes telescoping support frames and duct  
covers.  
5
Use  
5
Supplied  
Support  
and  
5
5
5
Duct Cover  
5
7’11"  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Advance Planning  
Equivalent Quantity Total  
DUCT FITTINGS  
Duct Piece  
Length*  
Used  
Length  
10" round  
Use this chart to compute maximum  
permissible lengths for duct runs to  
outdoors.  
For best results, use 10" diameter duct.  
Note: Do not exceed maximum permissible  
to 8" round  
5 ft.  
Round,  
straight  
1 ft.  
(per foot  
length)  
equivalent lengths!  
90° elbow  
45° elbow  
8" Dia. 52 ft.  
10" Dia. 24 ft.  
Maximum recommended duct  
length for these hoods: 150 feet  
8" Dia. 31 ft.  
10" Dia. 14 ft.  
Flexible ducting:  
If flexible metal ducting is used, all  
the equivalent feet values in the table  
should be doubled. The flexible metal  
duct should be straight and smooth  
and extended as much as possible.  
Round  
wall cap  
with damper  
8" Dia. 99 ft.  
10" Dia. 41 ft.  
Round  
roof cap  
8" Dia. 136 ft.  
10" Dia. 56 ft.  
Do NOT use flexible plastic ducting.  
Note: Any home ventilation system, such as a ventilation  
hood, may interrupt the proper flow of combustion air and  
exhaust required by fireplaces, gas furnaces, gas water  
heaters and other naturally vented systems. To minimize  
the chance of interruption of such naturally vented systems,  
follow the heating equipment manufacturer’s guidelines and  
safety standards such as those published by NFPA and  
ASHRAE.  
Total Duct Run  
Hoods Are Equipped  
For 10" Round Duct  
*Hoods are supplied with a 10"  
round transition. A locally  
supplied transition is required  
for other sizes.  
Note: Outlet on top of hood is  
8-1/8" x 8".  
*Actual length of straight duct plus duct fitting  
equivalent. Equivalent length of duct pieces are  
based on actual tests conducted by GE Evaluation  
Engineering and reflect requirements for good  
venting performance with any ventilation hood.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Preparation  
TOOLS AND MATERIALS REQUIRED  
7/16" Pivoting  
hex socket with 4"  
and 6" extensions  
(NOT SUPPLIED)  
Hammer  
Duct tape  
Electric or battery operated drill  
and 3/16", bits, Phillips and Flat  
Blade Screwdriver bits.  
Wire cutter/stripper  
Key Hole Saw  
Pencil and tape measure  
Spirit level  
10" round metal  
duct, length to  
suit installation.  
Safety glasses  
Wire nuts  
Flashlight  
Phillips and flat blade  
screwdrivers  
Saber saw  
or Sawsall  
Strain relief for  
junction cover.  
Step ladder  
120V 60Hz. 15 or 20 Amp,  
2-wire with ground. Properly  
grounded branch circuit.  
Pliers  
Metal Snips  
Carpenters square  
Carefully, lay the hood on its side. A support frame is  
secured to the inside top of the hood. Remove the  
attachment screws at the outside top. Discard screws.  
Grasp the support  
REMOVE THE PACKAGING  
Remove the parts packages and packing materials.  
Lift the hood out of the box.  
frame inside the  
hood with both  
hands and  
IMPORTANT:  
Lift the hood by grasping  
the outside edges of the exhaust opening on the top.  
carefully rotate out  
of the opening.  
Be careful not to  
Parts  
Parts  
Parts  
scratch the hood.  
Hood  
Motor  
Mounted  
on Skid  
Shipping Carton  
The hood motor is shipped secured to the skid with 4  
screws. Locate and remove 2 screws on each side of  
the motor. Discard the shipping skid and screws.  
Place the hood on a protective surface to prevent  
scratches and damage to the stainless steel finish.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Preparation  
PARTS PROVIDED  
Locate the parts packed with the hood.  
Allen Wrench  
Support frame for 8 ft. ceiling  
with 4 large pan head screws  
installed on the bottom corners.  
Transition with Damper  
Implement rods with standoffs  
2-piece decorative duct cover  
Duct collar  
Decorative top cover  
2 Filters (3 with 54" hood)  
2 Grease trays (3 with 54" hood)  
HARDWARE PACKAGE  
ACCESSORY PACKAGE  
Locate and check  
contents. Screws  
shown actual size.  
Check accessory package.  
Select the taller set for 96" to 104" ceilings.  
Select the shorter set for 86" to 96" ceilings.  
Discard unused set.  
Screws A  
4 (7/16")  
hex head  
wood  
screws  
2 Sets of Duct Covers  
Screws B  
2 (1/8" x 1-1/2")  
Phillips  
pan head  
screws.  
2 Support Frames  
with 8 height  
adjustment  
Screws D  
2 small  
Phillips  
head  
screws  
2 Templates  
screws  
Screws C  
8 blunt point  
Phillips  
4 Attachment Screws  
screws  
Screws E  
2 Phillips  
head wood  
screws  
Screw F  
Blower safety screw and lock washer,  
Phillips head M 6 x 16.  
Note: Hardware appearance may vary slightly.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 1 CONSTRUCT CEILING SUPPORT  
Plan the Location of the Hood and Ductwork  
Use a plumb bob to check the location. The  
countertop/cooktop below the hood must be centered  
with the hood.  
The hood should extend beyond the front and rear edge  
of the cooking appliance.  
The duct in the ceiling must be centered over the  
cooktop.  
Ceiling  
Ceiling  
Hood  
Ducting  
Centerline  
Hood  
Ducting  
Centerline  
Front  
Front  
18-1/8"  
15-7/8"  
36-1/4"  
31-3/4"  
Align With  
Center of  
Cooktop  
Align With  
Center of  
Cooktop  
Cooktop  
Cooktop  
Countertop  
Countertop  
54" Hood Side View  
42" Hood Side View  
Ceiling Support Structure  
At the hood location, install 2 x 4 cross framing between  
ceiling joists as shown. (2x4s are required to support the  
weight of the hood.)  
Arrange cross framing in the ceiling to suit the existing  
structure.  
Your ceiling joists will be like one of the following  
examples.  
12-3/4(42Hood)  
17(54Hood) Install  
EXAMPLE A  
Cross-Framing  
Symmetrically About  
Duct/Cooktop Centerline  
8 5/8”  
10Duct  
16Joist  
Spacing  
2x4 Cross  
Framing  
Align duct  
to center of  
Cooktop  
Front  
of  
Cooktop  
Outline  
Hood  
Top View Ceiling Joists Parallel to Front of Hood  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 1 CONSTRUCT CEILING SUPPORT  
CONTINUED  
12-3/4(42Hood)  
17(54Hood)  
Install Cross-  
Framing  
Symmetrically About  
Duct/Cooktop  
Centerline  
EXAMPLE B  
16Joist  
Spacing  
2x4 Cross  
Framing  
10Duct  
8 5/8”  
Front  
Cooktop  
Outline  
Align duct  
to center of  
Cooktop  
of  
Hood  
Top View Ceiling Joists Run Perpendicular to Front of Hood  
EXAMPLE C  
12-3/4(42Hood)  
2x4 Cross  
Framing  
17(54Hood) Install Cross-Framing  
Symmetrically About Duct/Cooktop  
Centerline  
8 5/8”  
10Duct  
16Joist  
Spacing  
Front  
of  
Align duct  
to center of  
Cooktop  
Hood  
Cooktop  
Outline  
Top View Ceiling Joists at Angle with Front of Hood  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 1 CONSTRUCT CEILING SUPPORT  
CONTINUED  
Secure each 2 x 4 block with at least four (4), #10 wood  
screws, 3long (not supplied). Use 8 wood screws  
total for the two supports.  
2x 4 Min.  
Cross Framing  
The cross framing must be accurately aligned to  
assure correct positioning of the hood.  
The cross framing must be level in all directions.  
Check with a spirit level and adjust if necessary.  
Ceiling  
Joist  
IMPORTANT: The ceiling structure must be capable of  
supporting the weight of the hood (approximately 300  
pounds) and any inadvertent user contact loads. The  
hood support frame will be supported by the 2 x 4  
cross framing.  
8-5/8"  
17"  
(54" Hood)  
12-3/4"  
(42" Hood)  
Height  
Adjustment  
Screw Holes  
Ductwork  
Ceiling Joint  
Use the shortest and straightest duct route possible.  
For satisfactory performance, duct run should not  
exceed 150 feet equivalent length for any duct  
configuration.  
10"  
Duct  
Refer to Duct Fittingschart to compute the maximum  
permissible length for duct runs to the outdoors.  
This vent hood must use 10round rigid duct.  
Install the house ductwork to run horizontally between  
ceiling joists or straight up through the roof.  
2x4  
Vent Straight Up  
Through The Ceiling  
Finish the Ceiling  
Finish the ceiling surface. Be sure to mark location of  
the ceiling joists and cross framing. Check to be sure  
the ceiling is level, use shims if necessary.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 2 MOUNT TEMPLATE  
Select the template for your hood size.  
Align the template with the marks on the ceiling and  
tape in place.  
Be sure the template is oriented correctly,  
with the front of the hood.  
Use a plumb to check to be sure the mounting  
holes will provide parallel alignment with the  
countertop below.  
Center punch all hole locations.  
1/4" Gap  
Drill pilot holes in the 4 screw locations. Use a  
3/16bit and drill approximately 1-1/2deep.  
Drive 4 Hex head wood screws (Screws A) into  
the center of the ceiling joists and cross framing.  
Leave a 1/4" gap to allow the screw head to  
engage the keyhole slots on the support frames.  
Cut the 10-1/2" duct opening through the sheet  
rock.  
Screws A  
STEP 3 SIZE AND INSTALL DUCTWORK  
Measure from house duct flange to bottom of  
support frame. Subtract 4-3/8" for clearance to the  
bottom of the support frame.  
House  
Duct  
Cut the 10duct length to size.  
Secure duct to house ducting with sheet metal screws.  
Seal all connections with duct tape.  
Attach the duct collar loosely, about 1" from the bottom  
of the duct using Screws B.  
Duct  
Length  
Duct  
Duct  
Collar  
Screws B  
4-3/8" Clearance  
to Bottom of Frame  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 4 INSTALL ACCESSORY (OR SUPPLIED) SUPPORT AND DUCT COVERS  
Install Small Pan Head  
Screws on Each Side  
Top Duct  
Cover  
Screws D  
Bottom Duct  
Cover  
Adjust  
Install  
Safety Screw  
on Each Side  
Frame to  
Install Stop  
Screw  
nstallation  
Height  
Screws E  
Stop Screw  
Storage Location  
Install supplied support frame OR telescoping  
accessory frame  
Hang the supplied support frame or telescoping  
accessory frame to the ceiling joists and cross framing  
on the 4 hex head screws by engaging the keyhole slots  
on the frame.  
CAUTION:  
The stop screw  
must be installed. Failure to do so could result in  
personal injury or damage to the duct cover. The stop  
screw will prevent the lower duct from sliding down  
while completing the installation.  
Check to be sure the support frame is level, vertically  
and horizontally.  
Tighten the hex head screws securely.  
Install safety screws, (Screws E) on each side of the  
frame.  
PRUDENCE  
Il faut mettre en place la vis de butée afin d’éviter des  
blessures ou dendommager lenceinte du conduit. La vis  
de butée empêche lenceinte inférieure du conduit de  
descendre pendant linstallation.  
Adjust telescoping accessory frame to length  
Remove the 8 frame adjustment screws. Adjust the  
lower support up or down to the pre-determined length.  
Reinstall and securely tighten the 8 adjustment screws.  
Slide the top (inner) accessory duct cover up and over  
the frame. Secure the duct cover to the frame as shown  
using Screws D.  
Secure house wiring  
Route house wiring through the ceiling and pull a length  
to reach the hood junction box, approximately 6below  
the support. Tape to the right side of the support frame.  
Locate and remove the safety stop screw. Slide bottom  
duct cover up and over the top duct cover. Align bottom  
duct screw hole to the hole in the frame. Hold the duct  
cover in place while installing screw.  
IMPORTANT: Again, check to be sure the support is  
level in both directions. There is no way to level the hood  
after the hood is secured to the frame.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 5 INSTALL DUCT TRANSITION  
STEP 6 INSTALL HOOD  
WITH DAMPER  
Note: THREE PEOPLE ARE REQUIRED TO  
COMPLETE THIS INSTALLATION!  
Bumper Pads  
Duct  
Transition  
1/4" Gap  
Attachment  
Screws  
Attachment  
Keyholes  
Screws C  
IMPORTANT: Remove shipping tape from damper and  
check that damper moves freely.  
Place the transition piece over the hood exhaust and  
secure with 4 Screws C provided.  
Use duct tape to seal the connection. Check to be  
sure the damper moves freely.  
Back out the hanging screws on the bottom of the  
support frame to a 1/4" gap.  
Lift the hood up to the support frame. Carefully align  
the hood keyhole to the screws on the support frame.  
Slide the hood to engage the keyhole slots.  
Tighten the screws.  
Install  
2 Safety  
Screws  
Screws C  
Install safety screws into the top of the hood as  
shown.  
Check hood level in both directions.  
STEP 7 CONNECT DUCT  
Loosen duct collar and slide  
Slide Duct  
Collar Down  
to Cover Gap  
down to cover gap between  
transition and house duct.  
Tighten collar  
screws and tape all joints.  
Seal all connections with duct  
tape.  
Note: Do not drive screws through this duct  
connection. Doing so will prevent proper damper  
operation.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 8 CONNECT ELECTRICAL  
Verify that power is turned off at the source.  
Install strain relief onto the knockout of the junction  
box.  
Insert house wiring through strain relief and tighten.  
Use wire nuts to connect incoming ground to green,  
white to white and black to black.  
Push wires into junction box and replace cover. Be sure  
wires are not pinched.  
WARNING:  
If house wiring is not  
2-wire with a ground wire, a ground must be provided  
by the installer. When house wiring is aluminum, be  
sure to use UL approved anti-oxidant compound and  
aluminum-to-copper connectors.  
ATTENTION –  
Si le câblage de la  
maison nest pas du type à deux fils avec un fil de  
terre, linstallateur doit fournir un circuit de terre.  
Quand les fils de la maison sont en aluminium, il  
prendre soin dutiliser de la pâte antioxidation  
approuvée par UL et des connecteurs pour  
laluminium-cuivre.  
STEP 9 INSTALL THE MOTOR  
Top  
IMPORTANT: Connector  
ends are designed to  
mate only one way.  
Outlet  
Match flat and round  
connectors as shown.  
Attachment  
Slot  
Spring  
Clip  
Attachment Screw  
and Washer  
Screw F  
Attachment  
Slot  
Spring  
Clip  
Junction Box  
From the inside of the hood, slip motor into the  
attachment slot on the left.  
Rotate motor upwards until it snaps into the spring  
clip on the right.  
Plug cable at the top of the hood into the junction box  
connector. Route cable so it wont be pinched or  
damaged when the duct cover is lowered.  
Secure the motor to the hood with the machine  
screw and lock washer (Screw is marked with red  
paint.)  
Plug blower cable into the connector on the blower.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 10 SLIDE DUCT COVER  
STEP 12 INSTALL RODS  
DOWN  
SKIP THIS STEP IF USING THE SUPPLIED DUCT  
COVER  
Use a flat blade screwdriver to install stand-offs into  
the bottom of the hood.  
Align implement rod to stand-offs with the screw hole  
towards the inside of the hood. Secure the rod to the  
stand-offs with the supplied Allen wrench.  
Follow the same procedure on the opposite side.  
Hold the duct cover in place and remove the  
temporary stop screw. Return the screw to the  
storage location for future use.  
Slide the lower duct cover down onto the hood.  
Remove  
Stop  
Screw  
Slide  
Duct  
Cover  
Down  
Screw  
Stand-offs  
Into Hood  
Stop Screw  
Storage Location  
Use Allen  
Wrench to  
Secure Rod  
to Stand-offs  
STEP 11 INSTALL FILTERS  
Place filter drip trays into the rear of the hood.  
Insert the filter into the upper opening and drop into  
the trays.  
To remove the filters, grasp the knobs and push the  
filter up and lift out.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 14 FINALIZE INSTALLATION  
STEP 13 INSTALL SUPPLIED DUCT  
COVER AND TOP COVER  
Check all lamps to assure tightness in sockets.  
Turn power on at the circuit breaker.  
Refer to the Owners Manual for operating and  
cleaning instructions.  
Install Duct  
Cover Screw  
on Each Side  
Screws D  
Install the supplied 2-piece duct cover over the  
support frame (if using supplied frame). Snap ends  
together.  
Secure duct covers to support frame with 2  
Screws D.  
For a more finished appearance, a top cover is  
supplied and should be installed whenever the top of  
the hood is visible.  
TIP: Place pieces  
of tape over ends  
of the cover to  
prevent scratching Tape  
the duct cover.  
Tabs  
Remove tape  
before installing  
screws.  
Engage tabs into slots on each side at the top of the  
hood. The covers should lay flat in the impression on  
top of the hood.  
Top Cover  
Screws C  
Install Screws  
Front and Back  
Install 2 Screws C to secure the cover to the hood at  
the front and back.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
STEP 15 INSTALLATION CHECKLIST  
Check Blower Safety Screw  
Check appearance and installation  
Use a spirit level to check that the hood is level.  
Review installation instructions to determine source  
of problem.  
Ensure that blower safety screw is securely tightened.  
See page 16, Step 9. If screw is missing, order  
replacement parts bag.  
Top covers (if used) should lay flat in the recess on  
top of the hood. Make sure side tabs are engaged in  
slots and the cover is secured with two screws.  
Check Operating Sound and Proper Air-Flow  
Turn blower to each speed setting and listen for rattles  
and vibration. You should notice an audible difference  
at each speed setting.  
Clean the hood surfaces and all filters. See the  
Owners Manual for cleaning instructions. They  
should be free of construction debris such as  
sawdust.  
Check for foreign material in transition.  
Check that blower screen is not damaged or pushed  
into the blower impeller.  
The damper should move freely. Listen for opening and  
closing while turning the unit on and off.  
Check that the damper is not damaged, does not  
vibrate and that damper bumper pads are in place.  
Order a damper replacement assembly if needed.  
Check that ductwork is 10" round. If duct type is not  
rigid and less than 10" round, inform the consumer that  
performance will be reduced.  
Check Lighting Function  
Check that power cable is plugged into the junction  
box on top of the hood.  
Turn halogen lamps to each setting. Note change in  
brightness at different settings.  
Check that each lamp bezel is secure. Turn to the right  
to tighten. Order replacement lamp bezel and socket  
assemblies if needed.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: While performing installations described in this book,  
safety glasses or goggles should be worn.  
For Monogram® local service in your area, call  
1.800.444.1845.  
Note: Product improvement is a continuing endeavor at  
General Electric. Therefore, materials, appearance and  
specifications are subject to change without notice.  
GE Consumer & Industrial  
Appliances  
General Electric Company  
Louisville, KY 40225  
ge.com  
Pub. No. 49-80209-3  
01-08 JR  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Coleman Camping Equipment 2000000142 User Manual
Continental Refrigerator Refrigerator SW72 12C FB User Manual
Craftsman Portable Generator 58032561 User Manual
Crown Audio Microphone CM 311A User Manual
DVS DVD Player VXM 2000 User Manual
Dymo Label Maker 360D User Manual
Edelbrock Automobile Parts 17931 User Manual
Elation Professional Indoor Furnishings ETP554 User Manual
Frigidaire Refrigerator GLHS68EE User Manual
Fusion Whiteboard Accessories CS AT1100 User Manual