Elation Professional Indoor Furnishings Power Wash 575E User Manual |
Instruction Manual
from software version 1.0
(instruction version 1.0)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of contents
1
2
Description of Device..........................................................................................................7
1.1 Safety Instructions.......................................................................................................8
Preparation and Installation..............................................................................................9
2.1 Mounting........................................................................................................................9
2.1.1 Clamps ..............................................................................................................9
POWER WASH 575E
2.2 Secure the POWER WASH 575E.....................................................................10
2.3 Connections..............................................................................................................11
2.3.1 Power supply .................................................................................................11
2.3.2 DMX.................................................................................................................11
2.4 Fuse............................................................................................................................11
3
The Menu Field...................................................................................................................12
3.1 Adjust the DMX- Address (D001)..........................................................................13
3.2 The Test Program (TEST)....................................................................................14
3.3 The Audio Program (AUDI)..................................................................................14
3.4 Lamp On/Off (LAMP).............................................................................................14
3.5 Reset (RESE)..........................................................................................................15
3.6 Running time of lamp and unit (TIME)..............................................................15
3.7 Continuous Color Wheel (FCOL)........................................................................15
3.8 Invert Pan Movement (RPAN)...............................................................................15
3.9 Invert Tilt Movement (RTLT).................................................................................15
3.10 Special Functions (SPEC).....................................................................................16
3.10.1Manual Drive (MANU)...............................................................................16
3.10.2Lamp On automatically (LAAU)..............................................................16
3.10.3Lamp Off via DMX (DLOF)........................................................................17
3.10.4DMX Input (DMXI)......................................................................................17
3.10.5Display (DISP).............................................................................................18
3.10.6Fixture Temperature (TEMP)....................................................................18
3.10.7Fan Control (FANS)....................................................................................18
3.10.8Adjustments and Calibrations (ADJU)....................................................19
3.10.9Default Settings (DFSE).............................................................................20
3.10.10 Position Feedback (FEED).................................................................20
3.10.11 Correction of faults (EFLG)..................................................................20
Elation Lighting
3
Download from Www.Somanuals.com. All Manuals Search And Download.
3.11 Error and Information Messages...........................................................................20
4
5
DMX Channel Selection (DMX Protocol).......................................................................22
Change the Lamp...............................................................................................................24
5.1 Safety Regulations....................................................................................................24
5.2 Realize the Lamp Change ......................................................................................24
POWER WASH 575E
Maintenance and Cleaning the POWER WASH 575E...........................................25
6
6.1 Safety Regulations....................................................................................................25
6.2 Circumference and Interval (rule-of-thumb).........................................................25
6.3 Cleaning the Optical System..................................................................................26
7
8
Technical Specification....................................................................................................26
Index .....................................................................................................................................30
Elation Lighting
4
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION: Congratulations, you have just purchased one of the most
innovative and reliable lighting fixtures on the market today! The Power Wash 575E™,
has been designed to perform reliably for years when the guidelines in this booklet are
followed. Please read and understand the instructions in this manual carefully and
thoroughly before attempting to operate this unit. These instructions contain
important information regarding safety during use and maintenance.
UNPACKING: Thank you for purchasing the Power Wash 575E™ by Elation
Professional®. Every Power Wash 575E™ has been thoroughly tested and has been
shipped in perfect operating condition. Carefully check the shipping carton for
damage that may have occurred during shipping. If the carton appears to be
damaged, carefully inspect your unit for damage and be sure all accessories
necessary to operate the unit have arrived intact. In the event damage has been found
or parts are missing, please contact our customer support team for further
instructions. Please do not return this unit to your dealer without first contacting
customer support at the number listed below.
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to
provide set up help and to answer any question should you encounter problems
during your set up or initial operation. You may also visit us on the web at
please contact Elation Professional®. Service Hours are Monday through Friday 9:00
a.m. to 5:00 p.m. Pacific Standard Time.
Voice:
Fax:
(323) 582-3322
(323) 582-3108
E-mail:
Forum:
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this
unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any
repairs yourself, doing so will void your manufactures warranty.
Please do not discard the shipping carton in the trash. Please recycle whenever
possible.
Elation Lighting
5
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY REGISTRATION: The Power Wash 575E™ carries a two year (730
days) limited warranty. Please fill out the enclosed warranty card to validate your
purchase. All returned service items whether under warranty or not, must be freight
pre-paid and accompany a return authorization (R.A.) number. The R.A. number must
be clearly written on the outside of the return package. A brief description of the
problem as well as the R.A. number must also be written down on a piece of paper
and included in the shipping container. If the unit is under warranty, you must provide
a copy of your proof of purchase invoice. Items returned without a R.A. number clearly
marked on the outside of the package will be refused and returned at cutomers
exspence. You may obtain a R.A. number by contacting customer support at (323)
582-3322.
DISCHARGE LAMP WARNING: This fixture is fitted with a
discharge lamp, which is highly susceptible to damage if
improperly handled. Never touch the lamp with your bare hands, as
the oil from your hands will shorten lamp life. Also, never move the
fixture until the lamps have had ample time to cool. Remember,
lamps are not covered under warranty conditions.
This fixture emits intense UV radiation, which is harmful to the eyes and skin. The
intense luminance of the lamp can cause severe damage to the retina. Never operate
this fixture with the protective covers removed, these covers have been specially
designed to shield against UV radiation.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into
the lamp at all times.
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce
lamp life and intensity.
To achieve the intensity associated with discharge lamps, these lamps use a gas
sealed in a high-pressure environment to emit a brilliant output. Due to the high
pressure involved with the construction of the lamp, the lamp may explode during
prolonged extensive use. This risk is increased with age; added care is encouraged
when dealing with older lamps. Thus, lamp should always be replaced at the end of
their recommended duty cycle. Extreme caution should be used when operated this or
any fixture fitted with a gas discharge lamp.
Never open this fixture while in use!
During the initial operation of this fixture, a light smoke or smell may emit from the
interior of the fixture. This is a normal process and is caused by excess paint in the
interior of the casing burning off from the heat associated with the lamp.
Elation Lighting
6
Download from Www.Somanuals.com. All Manuals Search And Download.
1 Description of Device
1
4
1. Moving Head
2. Carrying handles
3. LED- Display
4. Arm
5. Camlock system
3
2
5
8
9
15
6. Software-Update
connector
DMX IN
DMX OUT
7. Microphone- Intensity
8. DMX- Input
1.Ground
2.Data
3.Data
-
+
Min
M
a
x
Mic Sensvitiity
Software Update
9. DMX- Output
10. Fan (air inlet/outlet)
7
10
14
6
13
10
15
11.
Power On/Off
12. Mains supply
(Powercon)
Lamp Fuse
ElectronicFuse
Power input:90
50
-
/
260AVC,
60Hz
POWER
13. Fuse lamp
14. Fuse electronics
15. Carrying handles
12
11
Elation Lighting
7
Download from Www.Somanuals.com. All Manuals Search And Download.
1.1 Safety Instructions
POWER WASH 575E
The POWER WASH 575E is a High-Tech Product. To
guarantee a smooth operation, it is necessary to keep
following rules.
The manufacturer of this device will not take responsibility of
damages through disregard of the information in this manual.
Warranty adjustments will be cancelled.
1. Make sure before putting into operation, that the fan and the air inlets are
clean and not blocked by anything.
2. Attention: Don’t touch the device during the operation. This can cause
injuries or damages.
POWER WASH 575E
3. Unplug the POWER WASH 575E from the AC outlet before any
attempting any service.
4. It is necessary to wait at least 30 minutes after disconnecting the AC before
POWER WASH 575E
you open the POWER WASH 575E. Please do not touch the bulb of the
lamp if you are not absolutely sure it is cold. -- Danger of BURNING --
5. Never look directly into the beam of the lamp. You risk injury of your retina
and blindness.
6. Pay attention of the maximum lamp operation time. You have to change it if
the lamp shows any deformations or damages. The same is with all glass
components, color filters, lenses and mirrors.
7. To allow a secure operation, follow also the Installation guide described in
POWER WASH 575E
chapter 2. Operating the POWER WASH 575E without suited safety aids
like Safety cables or clamps/hooks can increase the risk of an accident.
8. Installation should be done by qualified staff only. You need to pay attention
to the common rules of technology that are not explicitly mentioned in this
manual.
9. Use only original spare parts. Any structural modification will cancel all
warranty adjustments.
Elation Lighting
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2 Preparation and Installation
2.1 Mounting
POWER WASH 575E
The POWER WASH 575E is fully operational whether it hangs or is mounted
to the wall. It can also be operated while standing on the floor. Keep a safety
distance of 0.5 m towards any easy inflammable materials (decoration etc.).
Install a safety wire that can hold at least 10 times the weight of the fixture. Never
use the carrying handles for secondary attachment.
Pay attention to the regulations of: BGV C1 (former VBG 70) and
DIN VDE 0711-217 !
The installation should be done by qualified staff only.
2.1.1 Clamps
POWER WASH 575E
There are two major possibilities to mount the POWER WASH 575E
together with clamps. Camlock system or direct mounting of clamps. In
both cases you have to regard a sufficient stability of the system. For
installation instructions please see also printing on the backside of the
case.
Elation Lighting
9
Download from Www.Somanuals.com. All Manuals Search And Download.
a) Camlock system: This system allows you a fast and efficient setup of
clamps. Attach the two camlocks to designated position on the
backside of the case and close the locks by turning them 90°. Verify
the secure fit of the camlock system. The clamps themselves are
directly attached permanently on the camlocks.
90°
POWER WASH 575E
b) Use two clamps direct on the backside of the POWER WASH 575E
to mount the unit on a truss (each two opposite threads max. M10x20).
4x M10x20mm
4x Camlock
POWER WASH 575E
2.2 Secure the POWER WASH 575E
POWER WASH 575E
Regardless of the rigging of the POWER WASH 575E you have to use a
stipulated safety wire. Therefore you have to thread to safety wire through to two
provided holes on the backside of the fixture and connect it with the truss-
support. Pay attention to a safe and proper fastening.
Elation Lighting
10
Download from Www.Somanuals.com. All Manuals Search And Download.
2.3 Connections
2.3.1 Power supply
Electronic ballast with:
~90 - 260 Volt, 50 - 60 Hz, earth contact type plug - Powercon
Connected load 780W <=> 3.8 A (blind current compensation).
Please see printing on the case for the right electronic supply!
2.3.2 DMX
DMX 512 Standard input/output. See also printing on the case for the right
pin assignment.
[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1
The DMX- Addressing starts at the DMX- Address [001].
2.4 Fuse
POWER WASH 575E
The POWER WASH 575E electronic system is protected by two 5x20 mm fine-
wire fuses.
Lamp: 230V / T 5A
Electronic: 230V / T 1A
POWER WASH 575E
Please see the printing on the POWER WASH 575E casing for more details.
Attention:
• Disconnect AC outlet before changing a fuse!
• Use only the original declared fuse type!
Elation Lighting
11
Download from Www.Somanuals.com. All Manuals Search And Download.
3 The Menu Field
You’ll find the control board on the side part of the base. It allows you to
POWER WASH 575E.
make all necessary adjustments of the POWER WASH 575E. With the
MODE ENTER DOWN UP
Mode-key you get into the main menu. Afterwards you can navigate through
the menu with the Up/Down-keys. Push the Enter-key to get in the next
menu level or to confirm your settings. Make them and set functions ON/OFF
with the Up/Down-keys. Confirm and save it with the Enter-key (the display
shows OK). Push the Mode-key to cancel the entry and go back to the main
menu.
MODE ENTER DOWN UP
Display
M N E O D
Level 1
D001
Level 2
Level 3
Remark
Define the DMX start address
Test program of all functions
TEST
AUDI
Self-running audio program (slow)
Self-running audio program (fast)
Master for the audio program
ASLW
AFST
MSTR
SVPT
SIZE
Basic position for the audio program
Size for the audio program (NORM-BIG-MIDL-SMAL)
POWER WASH
Switch on/of the lamp direct at the POWER WASH
LAMP
575E
575E
Reset
RESE
TIME
Running time of the fixture (no destructible)
Running time of the lamp (erasable)
Running time of the lamp (no destructible)
Reverse Pan-direction
POWR
LA1
LA2
FCOL
RPAN
RTLT
SPEC
Reverse Tilt-direction
Manual drive of all device functions
Automatic lamp start
MANU
LAAU
DLOF
DMXI
DISP
Switch off lamp via DMX
Reed out actual DMX-values
Display On/Off
Twist the display
D ON
REV
Reed out internal temperature
Maximum cooling fan velocity
Automatic cooling fan control
Low cooling fan speed ‡ lamp off
Low cooling fan speed ‡ automatic
Define the DMX start address
TEMP
FANS
HIGH
REG
LOOF
LOHI
CODE
xxxx
ADJU
Use the code for entering the calibration menu (for
authorized persons only)
Calibration of the Cyan color wheel
Calibration of the Magenta color wheel
Calibration of the Yellow color wheel
Calibration of the color wheel
CYAN
MAGE
YELL
COLO
BSPR
Calibration of the beam shape
Elation Lighting
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Calibration of the Zoom
ZOOM
Dimm
SHUT
CLRE
ARES
VTIL
VTRB1
VTRB2
CODE
xxxx
Calibration of the Dimmer
Calibration of the Shutter
Settings in the internal memory (super-user only)
Adjust Reset
Software version Tilt-board
Software version driver board 1
Software version driver board 2
Use the code for entering the calibration menu (for
authorized persons only)
COAD
Coarse calibration of the Cyan color wheel
Coarse calibration of the Magenta color wheel
Coarse calibration of the Yellow color wheel
Call on the default function values
CYAN
MAGE
YELL
DFSE
FEED
EFLG
Pan/Tilt feedback (error correction) On/Off
Correction of faults
3.1 Adjust the DMX- Address (D001)
POWER WASH 575E
Right after turning on the POWER WASH 575E you can see the current DMX-
Address. If there is no DMX- Signal the display flashes.
D001
For the address setting please follow this procedure:
POWER WASH 575E
1. Switch On the POWER WASH 575E and wait until the fixture reset has
finished ('RESE' is flashing in the display).
2. Press the Mode-key in order to access the main menu. Browse through the
menu by pressing the Up/Down-keys until the display shows D001. Confirm
by pressing the Enter-key (the decimal point is flashing)
3. Use the Up/Down-keys to select the desired address. Confirm the setting by
pressing the Enter-key (the display shows OK) or press the Mode-key to
cancel.
POWER WASH 575E
The DMX- Address is stored also while switching off the POWER WASH 575E!
Elation Lighting
13
Download from Www.Somanuals.com. All Manuals Search And Download.
3.2 The Test Program (TEST)
test
The Test-Program allows you to run a complete self test procedure of all
functions. Press Enter to confirm or Mode to cancel.
3.3 The Audio Program (AUDI)
Audi
The Audio-menu allows you to run a stand alone audio program. This chaser
can run either fast or slow. AFST: Every sound impulse on step of the chaser.
Aslw: Every second sound impulse one step of the chaser.
Additional you can choose a basic position for this audio chaser. Use therefore
either the internal manual mode or an external controller to set the desired
Pan/Tilt position. Confirm this setting in the SVPT menu by pressing the Enter-
key.
You can also set the size of the audio chaser in the SIZE menu. You have the
choice between: NORM (no basic position has to bee chosen), BIG, MIDL
and SMAL).
YPOCs
If you want to run the systems simultaneously, one of the YPOCs must be
switched as the master. All others must be "Slave" Master = OFF. Notice: The
Audio function is only working if no DMX is connected. This function can work e.g.
on small events or as an emergency program.
3.4 Lamp On/Off (LAMP)
LAMP
Use the Up/Down-keys to select lamp On or lamp Off Press Enter to confirm or
Mode to cancel and return to the main menu. (The lamp OFF command is only
working if the shutter is closed at the same time. Use an external controller or
the manual drive mode, see chapter 3.10.1.
Elation Lighting
14
Download from Www.Somanuals.com. All Manuals Search And Download.
3.5 Reset (RESE)
RESE
Press the Enter-key to run a reset of all fixture functions (RST is shown in the
display).
3.6 Running time of lamp and unit (TIME)
TIME
By this option can read out three different running times of the fixture.
Running time of the fixture (no destructible).
POWR
Running time of the lamp (erasable). Push the Up/Down-keys at one
time to delete this running time.
LA 1
Running time of the lamp (no destructible).
LA 2
3.7 Continuous Color Wheel (FCOL)
fcol
This function allows you to control the color wheel continuously. If it is switched
off, the color wheel is stepping directly from one to another color.
3.8 Invert Pan Movement (RPAN)
RPAN
This function allows you to invert the Pan movement. Use the Up/Down-keys to
select invert On or Off. Press Enter to confirm or Mode to cancel and return to
the main menu.
3.9 Invert Tilt Movement (RTLT)
RTLT
This function allows you to invert the Tilt movement. Use the Up/Down-keys to
select invert On or Off. Press Enter to confirm or Mode to cancel.
Elation Lighting
15
Download from Www.Somanuals.com. All Manuals Search And Download.
3.10 Special Functions (SPEC)
SPEC
POWER WASH
This menu allows you to enter further special functions of the POWER WASH
575E.
575E.
In detail they are:
3.10.1 Manual Drive (MANU)
MANU
This function allows you to drive all the fixture functions manually. Select
the desired function with the Up/Down-keys and confirm with Enter. Now
choose the desired value with the Up/Down-keys and confirm again with
Enter or cancel and return to the menu with the Mode-key.
Function
PAN
TILT
CYAN
MAGE
YELL
COLO
SHUT
Value
Remark
Pan Position
000 - 255
000 - 255
000 - 255
000 - 255
000 - 255
000 - 255
000 - 255
Tilt Position
Cyan color wheel
Magenta color wheel
Yellow color wheel
Color wheel (fixed colors)
Shutter / Strobe function (the lamp strikes at
DMX 255 if dimmer is "open" = DMX 255)
Dimmer
DIMR
BSPR
ZOOM
SPEC
000 - 255
000 - 255
000 - 255
000 - 255
Beam shape + Frost
Zoom
Lamp Off, Reset, ...
3.10.2 Lamp On automatically (LAAU)
LAAU
This function enables to switch On the lamp automatically after switching
On the fixture. Use the Up/Down-keys to select ON if you want to switch
on the lamp automatically after switching on the fixture or Off if you don't
want this function. Press Enter to confirm or Mode to cancel and return to
the menu.
Elation Lighting
16
Download from Www.Somanuals.com. All Manuals Search And Download.
If you have chosen off you have the possibility to start the lamp either via
POWER WASH 575E
DMX or direct at the POWER WASH 575E in the Lamp menu.
3.10.3 Lamp Off via DMX (DLOF)
DLOF
This function enables to switch off the lamp via DMX or not. Use the
Up/Down-keys to select ON if you want to switch off the lamp via DMX or
Off if you don't want this function. Press Enter to confirm or Mode to
cancel and return to the menu.
If you have chosen off you have the possibility to switch off the lamp
POWER WASH 575E
either direct at the POWER WASH 575E in the Lamp menu or switch off
the main switch.
3.10.4 DMX Input (DMXI)
DMXI
Readout DMX values of each channel received by the fixture. Use the
Up/Down-keys to select desired channel and press Enter to read its
value.
Function
PAN
TILT
Value
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Remark
Pan Position
Tilt Position
Cyan color wheel
Magenta color wheel
Yellow color wheel
Color wheel (fixed colors)
Shutter / Strobe function
Dimmer
CYAN
MAGE
YELL
COLO
SHUT
DIMR
BSPR
ZOOM
SPEC
MOVE
SPED
Beam shape + Frost
Zoom
Lamp Off, Reset, ...
Movement
Speed for Pan/Tilt
Elation Lighting
17
Download from Www.Somanuals.com. All Manuals Search And Download.
3.10.5 Display (DISP)
DISP
Use this function to choose between different display indications. Use the
Up/Down-keys to select desired function and press Enter to confirm or
Mode to cancel and return to the menu.
D ON Display On/Off (If you've chosen off, the display will go out within
15 seconds after the last input. The next key touch will reactivate
the display).
Turn around the display.
REV
Note: You can also do this by pushing the Up/Down-keys at the
same time.
3.10.6 Fixture Temperature (TEMP)
TEMP
This function allows you to read out the actual temperature of the
POWER WASH 575E
POWER WASH 575E. Press Enter to confirm or Mode to cancel. Inside
temperatures below 80°C are not critical. 80°C and more lead the lamp
being switched off at a critical point. Please note for a save operation that
the outside temperature should not exceed 45°C.
3.10.7 Fan Control (FANS)
FANS
By using this function you can choose between 4 types of fan speed
operations. Use the Up/Down-keys to select desired function and press
Enter to confirm or Mode to cancel and return to the menu.
The cooling fan works continuously at max. speed.
HIGH
The fan automatically raises its speed in order to control inside
temperature of the fixture.
REG
The fan keeps the adjusted low speed until the temperature
POWER WASH
exceeds max. inside temperature, then the POWER WASH
LOOF
575E
575E automatically switch off the lamp.
The fan keeps the adjusted low speed until the temperature
LOHI
Elation Lighting
18
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER WASH
exceeds max. inside temperature, then the POWER WASH
575E
575E automatically switch from low to high fan speed.
In addition to these settings, you can set to fan speed to minimum via
DMX (Special channel, DMX value 224..229). This will last until a tempera-
ture of 90° is reached.
3.10.8 Adjustments and Calibrations (ADJU)
ADJU
By this function you can adjust and calibrate the positions of the different
wheels and other motors. This can be necessary after a service or repair
work.
For this function you have to entry the fixture code. This work should be
done only by authorized persons.
Use the Up/Down-keys to select desired function and press Enter to
confirm or Mode to cancel and return to the menu. Use now the Up/Down-
keys to set the adjustment values and confirm once more with the Enter-
key or cancel with the Mode-key.
Function
Value
CODE
xxxx
Remark
Adjustments in the internal setup are code protec-
ted (for authorized persons only).
ADJU
Adjustment of the Cyan color wheel
Adjustment of the Magenta color wheel
Adjustment of the Yellow color wheel
Adjustment of the Color wheel
Adjustment of the Beam shape
Adjustment of the Zoom
CYAN - 99 - + 99
MAGE - 99 - + 99
YELL - 99 - + 99
COLO - 99 - + 99
BSPR - 99 - + 99
ZOOM - 99 - + 99
DIMM - 99 - + 99
SHUT - 99 - + 99
Adjustment of the Dimmer
Adjustment of the Shutter
Adjustments in the internal circuit.
CLRE
Adjust Reset (wheels stand still after the reset)
Software version of Tilt-board
ARES - 99 - + 99
VTIL
- 99 - + 99
Software version of Head- board
Software version of Base- board
VTR1 - 99 - + 99
VTR2 - 99 - + 99
Adjustments in the internal setup are code protec-
ted (for authorized persons only).
COAD
CODE
xxxx
Coarse adjustment of the Cyan color wheel
CYAN - 99 - + 99
Elation Lighting
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Coarse adjustment of the Magenta color wheel
Coarse adjustment of the Yellow color wheel
MAGE - 99 - + 99
YELL - 99 - + 99
3.10.9 Default Settings (DFSE)
DFSE
Press Enter to reset all fixture personalities (not the adjusted functions) to
the default values. On the display will appear ok to indicate that the de-
faults are set.
Function
DMX Address
Display
D001
Default Settings
D001
Pan reverse
Tilt reverse
RPAN
RTLT
LAAU
DLOF
DISP
ON
ON
ON
ON ¸
D ON ¸
OFF ¸
OFF ¸
OFF ¸
OFF
Automatic lamp on
Lamp on via DMX
Display
Cooling fan
FANS
FEED
HIGH REG ¸ LOOF LOHI
ON ¸ OFF
Feedback
3.10.10 Position Feedback (FEED)
FEED
POWER WASH 575E
The POWER WASH 575E is provided with a automatic position
correction (feedback) for the Pan and Tilt movement. Use the Up/Down-
keys to select ON if you want to enable the feedback function or Off if you
don't want this function. Press Enter to confirm or Mode to cancel and
return to the menu.
3.10.11 Correction of faults (EFLG)
EFLG
(Function available for authorized persons only)
3.11 Error and Information Messages
This message appears if you try to switch on the lamp within 5
HEAt
Elation Lighting
20
Download from Www.Somanuals.com. All Manuals Search And Download.
minutes after having switched off (lamp too hot). The message will
appear on the display if the lamp doesn’t ignite within 20 seconds.
The fixture will store this command and automatically ignite the lamp
after 5 minutes.
When igniting the lamp, the electronic ballast will examine whether the
lamp ignited or not. If the lamp does not ignite within 20 seconds, the
igniting sequence is broken off. Now approx. 2 minutes are waited,
until a renewed ignition attempt is started automatically. After the 3rd
unsuccessful ignition attempt the sequence is completely stopped
IG E
and the display reads "IG E" (Ignition error).
As soon as the lamp ignited correctly, the lamp current is constantly
supervised by the system. If an interruption steps on (covers opened
or lamp damaged), the power is switched off immediately. The display
LAER
reads "LAER" (lamps error). Please switch off the power supply and
solve the possible problem.
After the error "IG E" respectively "LAER" it is not anymore possible the start
the lamp via Shutter = 255. Nevertheless if a renewed ignition attempt is
desired, first run a Reset (at the Spot or over DMX). Afterwards you can try again
to ignite the lamp.
This error message informs you that the fixture was overheating and
OTMP
that the relay switches off the lamp. Pleas look for possible reasons
(fan faulty, air in/outlets blocked or very dirty, lamp broken or very old,
too high ambient temperature. Switch off the power supply and solve
the possible problem.
This message informs you that one of the fixture function wasn’t able
to do its reset correct (magnetic sensor, stepping motor, driver on the
PCB, cables, etc.). Repair the defect and start the fixture again.
RsER
Elation Lighting
21
Download from Www.Somanuals.com. All Manuals Search And Download.
4 DMX Channel Selection (DMX Protocol)
Channel
Function
Time and Value
min. 2,65 s
DMX
HEX
%
1) PAN-
coarse
0 .. 530°
0..255
00..FF 0..100
2) PAN-fine Low- Pos ... High- Pos + 2,1° (16 Bit)
0..255
0..255
00..FF 0..100
00..FF 0..100
3) Tilt-
0 .. 285°
min. 1,8 s
coarse
4) Tilt-fine
5) Color*
Low- Pos … High- Pos + 1,1° (16 Bit)
open (fast)
color 1, Brilliant Blue (fast)
color 2, Blue (fast)
0..255
0..3
4..7
00..FF 0..100
Chaser from color to
color max. 140 BPM
‡ 0,43 s
00..03
04..07
08..0B
0,2
1,8
3,3
8..11
color 3, Blue Purple (fast)
color 4, Pink (fast)
color 5, Orange (fast)
color 6, Italian Blue (fast)
color 7, Turquoise (fast)
color 8, Jade (fast)
color 9, CTB 001 (fast)
color 10, CTO 02 (fast)
color 11, Red (fast)
open (fast)
open (slow)
color 1, Brilliant Blue (slow)
color 2, Blue (slow)
color 3, Blue Purple (slow)
color 4, Pink (slow)
12..15 0C..0F
4,9
6,5
8,0
9,6
16..19
20..23
10..13
14..17
24..27 18..1B
28..31 1C..1F
11,2
12,7
14,3
15,9
17,5
19,0
25,3
26,9
28,4
30,0
31,6
33,1
34,7
36,3
37,8
39,4
32..35
36..39
20..23
24..27
40..43 28..2B
44..47 2C..2F
48..63
64..67
68..71
30..3F
40..43
44..47
Chaser from color to
color max. 70 BPM
‡ 0,86 s
72..75 48..4B
76..79 4C..4F
80..83
84..87
50..53
54..57
color 5, Orange (slow)
color 6, Italian Blue (slow)
color 7, Turquoise (slow)
color 8, Jade (slow)
88..91 58..5B
92..95 5C..5F
96..99
60..63
color 9, CTB 001 (slow)
100..10 64..67
3
color 10, CTO 02 (slow)
color 11, Red (slow)
104..10 68..6B
41,0
42,5
44,1
7
108..11 6C..6F
1
112.127 70..7F
open (slow)
color rotation, slow-fast, CW
min. 1.4 turns/h
128..19 80..BF 50..75
1
color rotation, fast-slow, CCW
Audio color chaser slow
Audio color chaser fast
max. 2.9 turns/sec.
192..25 C0..FD 76..98
3
each 4th sound impulse
‡ new color
each sound impulse
‡ new color
254
FE
99
255
FF
100
6) Cyan
Cyan color intensity 0% - 100%
0..255
0..255
0..255
0..15
00..FF 0..100
00..FF 0..100
00..FF 0..100
7) Magenta Magenta color intensity 0% - 100%
8) Yellow
9) Shutter
Yellow color intensity 0% - 100%
Shutter closed
00..0F
0..6
Random Strobe (different pattern)
Strobe Pulse effect , slow - fast
16..31
32..47
10..1F 7..11,9
20..2F 12..12,
9
min. frequency 0,7 Hz
max. frequency 10 Hz
Strobe effect , slow - fast
48..239 30..EF 13..93
Elation Lighting
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Channel
Function
Time and Value
DMX
HEX
%
Shutter open
240..25 F0..FF 94..100
5
Lamp ON (ignition)
254..25 FE..FF 99..100
5
10) Dimmer Dimmer closed (0%)
0..3
0..3
0..1
Dimmer 1%...99%
movement time 0,3
Sek.
4..251
4..FB
2..98
Dimmer open (100%)
252..25 FC..FF 99..100
5
11) Beam-
shape
Open
Shaper
Frost
0..15
16..239 10..EF
240..25 F0..FF 95..100
5
0..0F
0..5
6..94
12) Zoom
13) Special No function
Audio CMY chaser slow
Zoom 0% - 100%
8° - 22°
0..255
0..15
16..23
24..31
32..63
64..79
00..FF 0..100
00..0F
10..17
0..6
7..9
Audio CMY chaser fast
Rotating color chaser
Color chaser C / C+1
slow – fast
18..1F 10..12
20..3F 13..24
40..4F 25..31
Color chaser C / C+2
slow – fast
80..95
50..5F 32..37
PAN/Tilt chaser slow
PAN/Tilt chaser fast
96..111 60..6F 38..43
112..12 70..7F 44..50
7
Lamp OFF
(only if shutter is closed)!
230..24 E6..F9 92..97
9
Reset
250..25 FA..FF 98..100
5
14) Move-
ment
No movement
Movement
PAN
0
00
0
Size
1
1
1
1
2
2
2
2
3
3
3
3
4
4
4
4
Phase
0°
01..01
02..03
04..05
06..07
08..09
10..11 0A..0B
12..13 0C..0D
14..15 0E..0F
16..17
18..19
20..21
22..23
24..25
26..27 1A..1B
28..29 1C..1D
30..31 1E..1F
01..01
02..03
04..05
06..07
08..09
0,5
1,0
1,7
2,5
3,3
4,1
4,9
5,7
6,5
7,3
8,0
8,8
9,6
10,4
11,2
12
90°
180°
270°
0°
PAN
PAN
PAN
90°
180°
270°
0°
11..11
12..13
14..15
16..17
18..19
90°
180°
270°
0°
90°
180°
270°
TILT
PAN / TILT
PAN / TILT (inverse)
Circle
size / phase see also PAN
size / phase see also PAN
size / phase see also PAN
size / phase see also PAN
32..63
64..95
20..3F 13..25
40..5F 26..37
96..127 60..7F 38..50
128..15 80..9F 51..62
9
Circle (inverse)
size / phase see also PAN
160..19 A0..BF 63..75
1
Elation Lighting
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Channel
Function
Time and Value
size / phase see also PAN
DMX
HEX
%
lying eight
192..22 C0..DF 76..87
3
random movement
size see also PAN
224..25 E0..FF 88..100
5
15) Speed
Pan/Tilt
Pan/Tilt relative movement
Pan/Tilt slow – fast
0..01
00..01
0..1
Pan Min. 530° = 200 s 02..255 02..FF 2..100
Use this channel 14) also for the Pan Max. 530° = 2.65
speed of the movements (channel s
13).
Tilt Min. 285° = 110 s
Tilt Max. 285° = 1.8 s
Lampe ON Shutter open
Channel 9 ( min. 3 sec. ) (only if
254..25 FE..FF 99..100
5
230..24 E6..F9 92..97
9
Lampe OFF
shutter is closed, channel 9 = 0 ..15)
*) Set the function “FCOL” ‘ON’ if you want to control the color wheel continuously.
5 Change the Lamp
For a frictionless operation pleas read this chapter carefully and follow all instructions.
5.1 Safety Regulations
• Pull out the main plug!
• Wait min. 20 minutes after the last operation to cool down the fixture.
• Don’t touch the bulb of the lamp with bare fingers (this can cause damages).
POWER WASH 575E
• Before you put the POWER WASH 575E into operation close the casing,
otherwise your retina can be hurt!
5.2 Realize the Lamp Change
1. Pull out the main plug!
2. The lamp can be changed in a very comfortable way directly from the
backside of the case without opening the head.
3. Open the four recessed head screws (1, 2, 3 and 4) of the backside lamp
sheet and remove it carefully.
4. Remove the old or broken lamp by opening the two sidewise lamp screws.
Attention: The glass bulb of the lamp can splinter. For that reason remove
the lamp with safety gloves or some cloth.
5. Put in the new lamp securely with a tight fit into the socket and close the two
Elation Lighting
24
Download from Www.Somanuals.com. All Manuals Search And Download.
lamp screws. The lamp filler neck must not in the direction lamp or lenses.
Attention: Use only the original lamp type!
6. Pull the lamp holder safely back in the shaft and close the four screws.
7. The running time of the lamp LA1 can be reseed in the Time Menu.
6
POWER WASH 575E
6 Maintenance and Cleaning the POWER WASH 575E
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-
fluid residues must not built up on or within the fixture. Otherwise the fixture's light-
output will be significantly reduced. Regular cleaning will not only ensure the
maximum light-output, but will also allow the fixture to function reliable throughout its
life.
A soft lint-free cloth moistened with any good glass cleaning fluid is recom-
mended, under no circumstances should alcohol or solvents be used!
The inside optical system should be maintained only by authorized persons. Please
contact your local dealer.
6.1 Safety Regulations
• Pull out the main plug!
• Wait min. 20 minutes after the last operation to cool down the fixture.
POWER WASH 575E
• Before you put the POWER WASH 575E into operation close the casing,
otherwise your retina can be hurt!
6.2 Circumference and Interval (rule-of-thumb)
The contamination of the fixture depends on the environment details. Therefore
no general guidelines can be given. From this it follows that the intervals are only
suggestions from our practice experience.
Position
Interval
In this way
Outside optic
Color filter
Beam shape
Dimmer/Shutter
Fan and air channel
Reflector
weekly
monthly
monthly
yearly
monthly
never
never
soft cloth and glass cleaning fluid
soft cloth and glass cleaning fluid
soft cloth and glass cleaning fluid
vacuum cleaner, airbrush, etc.
vacuum cleaner, airbrush, etc.
Lamp
Elation Lighting
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Moveable parts
yearly
suitable fatty oil
Attention:
• Never let optical parts come into contact with oil or fat.
• Before running the fixture wait until all parts are dried up.
6.3 Cleaning the Optical System
1. Pull out the main plug!
2. Wait min. 20 minutes after the last operation to cool down the fixture.
3. Open the upper shell of the head casing by loosening the 4 Phillips screws.
Two on the front side and two on the back side of the head.
4. Do the work as explained in the list above.
POWER WASH 575E
5. Before you put the POWER WASH 575E into operation close the casing,
otherwise your retina can be hurt!
7 Technical Specification
Power supply
Power consumption
~90 - 260V, 50 - 60 Hz
780 Watt, 3.8A, electronic ballast, (blind current compensated)
Lamp: T 5A, 250V, 5x20 mm (fine-wire fuse)
Electronic: T 1A, 250V, 5x20 mm (fine-wire fuse)
Fuse protection
Lamp
Type
Live time
HTI 575-DE (OSRAM)
500h (750h)
Color temperature
luminous flux
Optical system
Glass reflector
Fresnell lens 150mm
Color
5600k or 7500k
43.000 lm
9 dichroic filter plus white plus 1x CTC 5600k, 1x CTC 3300k
Beam shape
Stepless Beam shape
Frost filter
Motor driven focus from near to far away
Zoom: Motor driven variable angle of reflected beam from 8° to 22°
Shutter / Strobe / Dimmer
Strobe- effect with variable speed 1 - 10 flashes per second
Continuously mechanical dimmer 0 - 100%
Drive
Elation Lighting
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
The DMX- addressing starts at the DMX- address [001].
Pan / Tilt
Pan- movement
Tilt- movement
530° in max. 2,65 seconds, 16 bit resolution
280° in max. 1,68 seconds, 16 bit resolution
Weights and measures
Width of the base
Length of the base
380 mm
390 mm
height (head vertical) 520 mm
Weight (net)
19 kg
Elation Lighting
27
Download from Www.Somanuals.com. All Manuals Search And Download.
2 YEAR (730 DAYS) LIMITED WARRANTY
A. Elation Professionals® hereby warrants, to the original purchaser, Elation
Professionals® products to be free of manufacturing defects in material and
workmanship for a period of two years (730 days) from the date of purchase. This
warranty shall be valid only if the product is purchased within the United States of
America, including possessions and territories. It is the owner’s responsibility to
establish the date and place of purchase by acceptable evidence, at the time service is
sought.
B. For warranty service, send the product only to the Elation Professionals® factory.
All shipping charges must be pre-paid. If the requested repairs or service (including
parts replacement) are within the terms of this warranty, Elation Professionals® will
pay return shipping charges only to a designated point within the United States. If the
entire instrument is sent, it must be shipped in its original package. No accessories
should be shipped with the product. If any accessories are shipped with the product,
Elation Professionals® shall have no liability whatsoever for loss of or damage to any
such accessories, or for the safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the
product is modified in any manner which Elation Professionals® concludes, after
inspection, affects the reliability of the product; if the product has been repaired or
serviced by anyone other than the Elation Professionals® factory unless prior written
authorization was issued to purchaser by Elation Professionals®; if the product is
damaged because not properly maintained as set forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance,
cleaning or periodic check-up. During the period specified above, Elation
Professionals® will replace defective parts at its expense, and will absorb all
expenses for warranty service and repair labor by reason of defects in material or
workmanship. The sole responsibility of Elation Professionals® under this warranty
shall be limited to the repair of the product, or replacement thereof, including parts, at
the sole discretion of Elation Professionals®. All products covered by this warranty
were manufactured after January 1, 1990, and bare identifying marks to that effect.
E. Elation Professionals® reserves the right to make changes in design and/or
improvements upon its products without any obligation to include these changes in
any products theretofore manufactured.
Elation Lighting
28
Download from Www.Somanuals.com. All Manuals Search And Download.
F. No warranty, whether expressed or implied, is given or made with respect to any
accessory supplied with products described above. Except to the extent prohibited by
applicable law, all implied warranties made by Elation Professionals® in connection
with this product, including warranties of merchantability or fitness, are limited in
duration to the warranty period set forth above. And no warranties, whether expressed
or implied, including warranties of merchantability or fitness, shall apply to this
product after said period has expired. The consumer’s and or Dealer’s sole remedy
shall be such repair or replacement as is expressly provided above; and under no
circumstances shall Elation Professionals® be liable for any loss or damage, direct or
consequential, arising out of the use of, or inability to use, this product.
G. This warranty is the only written warranty applicable to Elation Professionals®
products and supersedes all prior warranties and written descriptions of warranty
terms and conditions heretofore published.
H. Lamps are not covered under this or any other warranty either written or implied.
Elation Lighting
29
Download from Www.Somanuals.com. All Manuals Search And Download.
8 Index
A
M
Audio.......................................................... 11
Maintenance.............................................. 21
Measures.................................................... 23
Mounting...................................................... 7
B
BGV C1........................................................ 7
P
C
Pan- movement .......................................... 23
Power supply................................................ 9
Circumference............................................. 22
Cleaning..................................................... 22
S
D
Safety Instructions...................................... 6
Secure......................................................... 8
Description of Device.................................. 5
DIN VDE 0711-217....................................... 7
Display........................................................ 15
DMX ............................................................. 9
DMX- Adresse............................................ 11
T
Test Program.............................................. 11
Tilt- movement ............................................ 23
E
V
Error Messages......................................... 18
VBG 70 ........................................................ 7
F
W
Fan............................................................. 15
Weights ...................................................... 23
Fuse............................................................. 9
I
Injury of the retina......................................... 6
Invert.......................................................... 13
Elation Lighting
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Elation Professional
4295 Charter Street
Los Angeles, CA. 90058
323-582-3322 / 323-582-3108 fax
Elation Lighting
31
Download from Www.Somanuals.com. All Manuals Search And Download.
|