Eaton Electrical Network Card QSNAP User Manual

Intelligent Technologies  
QCPort Starter Network Adapter Product  
(QSNAP)  
Installation and User Manual  
Publication No. MN05001001E  
February 2002  
New  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Table of Contents  
PRODUCT OVERVIEW  
Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Environmental Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Approvals/Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Catalog Numbering System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
2
3
4
4
4
PHYSICAL FEATURES  
Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Power Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5
5
6
OPERATION  
“Out of Box” Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Typical Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
8
9
Enhanced Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Input/Output Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Input Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Output Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Status LED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Truth Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
CONFIGURATION  
Using CH Studio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
INSTALLATION  
Set the Group ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
SW1 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Mount the IT. QSNAP to the Starter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Wire the IT. QSNAP to the Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Connect the QSNAP to QCPort. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
TROUBLESHOOTING AND MAINTENANCE  
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
APPENDIX A: QSNAP PARAMETERS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
INTELLIGENT TECHNOLOGIES (IT.) PUBLICATIONS AND SUPPORT. . . . . . . . . . . . . . 23  
Pub. No. MN05001001E  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
List of Figures  
Figure 1: QSNAP Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5
5
6
9
Figure 2: QSNAP Dimensions, mm [in] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Figure 3: Starter Interface Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Figure 4: Typical QSNAP Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Figure 5: Group ID Setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
Figure 6: QSNAP with 54 mm IT. Starter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Figure 7: QSNAP Alignment and Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Figure 8: QSNAP Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17  
Figure 9: Jumper and RJ-45 Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Figure 10: Jumper Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Figure 11: QCPort Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
Figure 12: QCPort Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
List of Tables  
Table 1: QSNAP Electromechanical Starter Connectivity Table . . . . . . . . . . . . . . .  
Table 2: QSNAP S751 Connectivity Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Table 3: Environmental Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Table 4: Approvals/Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Table 5: Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Table 6: Default Input Data from QSNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Table 7: Default Output Data to QSNAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
4
4
6
8
8
Table 8: Standard Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Table 9: Enhanced Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Table 10: Input Assembly Data Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11  
Table 11: Default Input Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Table 12: Default Output Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Table 13: Output Assembly Data Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
Table 14: Status LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Table 15: QSNAP Truth Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
Table 16: SW1 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Table 17: Starter Size/Available Auxiliary Locations on Mounted QSNAP . . . . . . 16  
Table 18: Terminal Block Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Table 19: QSNAP Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
Table 20: Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
Table 21: Configuration Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
Table 22: Data Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22  
Table 23: IT. Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Pub. No. MN05001001E  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Product Overview  
Description  
Cutler-Hammer Intelligent Technologies (IT.) QSNAP (QCPort Starter Network Adapter  
Product) by Eaton Corporation is the result of a substantive engineering and marketing effort,  
involving extensive customer input. This product has greatly increased functionality of the  
Eaton’s Cutler-Hammer Intelligent Technologies (IT.) Electromechanical Starter with the  
addition of enhanced features, such as jam, stall and underload. This single front-mount  
device is a single QCPort™ (Quick Connect Port) device providing control and monitoring of  
Intelligent Technologies (IT.) Electromechanical Starter application.  
The QSNAP product line provides communication capability to the following Intelligent  
Technologies (IT.) Electromechanical Starters.  
Table 1: QSNAP Electromechanical Starter Connectivity Table  
IEC  
E101  
E501  
NEMA  
N101  
N501  
Amperage  
Rating  
Frame  
Size  
Frame  
Size  
18 Amp  
25 Amp  
32 Amp  
40 Amp  
50 Amp  
65 Amp  
85 Amp  
100 Amp  
125 Amp  
160 Amp  
200 Amp  
250 Amp  
315 Amp  
400 Amp  
B
45 mm  
00  
0
45 mm  
C
D
54 mm  
76 mm  
1
2
54 mm  
76 mm  
E
F
105 mm  
140 mm  
3
4
105 mm  
140 mm  
5
Table 2: QSNAP S751 Connectivity Table  
S751  
All  
This manual specifically addresses the QCPort Starter Network Adapter Product (QSNAP).  
For further information on the IT. family of devices, visit our Web site at:  
Notice  
Because the IT. Starters use 24V DC for control and power, the  
QSNAP can only be applied with the IT. family of starters.  
Pub. No. MN05001001E  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Features and Benefits  
The IT. QSNAP includes the following significant features:  
 
 
Communication to QCPort consuming a single QCPort ID  
Control of non-reversing and reversing Eaton’s Cutler-Hammer Intelligent Technologies  
(IT.) Electromechanical Starters  
 
 
Monitoring of non-reversing and reversing Eaton’s Cutler-Hammer Intelligent  
Technologies (IT.) Electromechanical Starters  
Direct mounting to the front of Eaton’s Cutler-Hammer Intelligent Technologies (IT.)  
Electromechanical Starter  
 
 
 
Connection to an auxiliary ground fault detector  
Sensing of the second contactor  
Manually set Group ID; configuration using a software application is not required for  
normal operation  
 
 
 
Enhanced features, such as jam and stall detection and nuisance trip avoidance  
Warning levels that are user-settable  
Settable current threshold alarm  
Pub. No. MN05001001E  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Safety  
The following safety statements relate to the installation, setup and operation of Eaton’s  
Cutler-Hammer IT. QSNAP and Starter.  
Notice  
Make sure you read and understand the installation procedures in  
this manual before you attempt to operate or set up the equipment.  
WARNING  
This instruction manual should be used for proper installation,  
setup and operation of the IT. QSNAP. Improperly installing and  
maintaining this product can result in serious personal injury or  
property damage. Before attempting installation, setup or  
operation, read and understand this entire manual.  
WARNING  
Hazardous voltage can cause electric shock and burns. Always  
disconnect power before proceeding with any work on this product.  
CAUTION  
Only apply 24V DC to the QSNAP power terminals. Use of any other  
voltage may result in personal injury, property damage and  
damage to the IT. QSNAP.  
WARNING  
To provide continued protection against fire or shock hazard, the  
complete IT. QSNAP must be replaced if it becomes inoperative.  
Pub. No. MN05001001E  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Environmental Ratings  
The following environmental ratings apply to the QSNAP.  
Table 3: Environmental Ratings  
Category  
Description  
Specification  
Transportation  
Temperature  
Humidity  
Temperature  
Humidity  
Temperature  
Humidity  
Altitude  
-50°C to 80°C [-58°F to 176°F]  
95% non-condensing  
Storage  
-50°C to 80°C [-58°F to 176°F]  
95% non-condensing  
Operating  
-30°C to 55°C [-22°F to 131°F]  
95% non-condensing  
Above 2000 meters [6600 feet] consult factory  
15 g’s half-wave sinusoidal 11 msecs  
5 – 57.5 Hz (100 – 17 msecs) @ 0.3 mm SA  
57.5 – 150 Hz (17 – 6.7 msecs) @ 0.35 mm SA  
IP20  
Shock  
Vibration  
Enclosure  
Approvals/Certifications  
The following approvals and certifications apply to the QSNAP.  
Table 4: Approvals/Certifications  
Standard  
Approval/Certification  
UL  
UL508  
CE  
CSA  
CSAC22.2 No. 14-95  
Catalog Numbering System  
There is only one catalog number for QCPort connection to Eaton’s Cutler-Hammer Intelligent  
Technologies (IT.) Electromechanical Starters. These starters include those listed in Table 1  
on Page 1.  
The catalog number is QSNAP.  
This part number includes the QSNAP and the starter interface board that connects the  
starter and the QSNAP.  
Note: When ordering QSNAP for Full Voltage Reversing, consult factory for the QSNAP  
Auxiliary contact and jumper catalog numbers.  
Note: When ordering a ground fault detector, consult factory for catalog number.  
Pub. No. MN05001001E  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Physical Features  
Physical Description  
Figure 1 illustrates the front and back of the IT. QSNAP and its various features.  
Group ID  
Switch  
Feet  
Contactor  
Detector  
Connector  
Breakout  
Lock  
Lock Tab  
Starter  
Connector  
Status  
LED  
Figure 1: QSNAP Features  
Dimensions  
Figure 2 illustrates the dimensions of the IT. QSNAP.  
Front  
Side  
62  
[2.4]  
26  
[1.0]  
32  
[1.3]  
Figure 2: QSNAP Dimensions, mm [in]  
Pub. No. MN05001001E  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Power Source  
The IT. QSNAP is designed for use with 24V DC power. The QSNAP uses power from two  
sources when operating properly; these sources are the QCPort subnet and the Eatons  
Cutler-Hammer Intelligent Technologies (IT.) Electromechanical Starter. This allows the  
QSNAP to detect and communicate to the user that the IT. starter does not have 24V DC  
power, signaling a fault or an E-Stop.  
The main power that powers the communication is from QCPort, as illustrated in Table 5.  
Some power is required from the starter for communication to be present between the  
Intelligent Technologies (IT.) Electromechanical Starter and the QSNAP.  
The power for the IT. starter must be connected to the starter terminal.  
Table 5: Power Requirements  
Current Source  
Load  
QCPort  
TBD  
TBD  
IT. Starter  
When a power supply is chosen for QCPort, take into account the load on QCPort. When a  
power supply is chosen for the starter(s), size it for the load of the starter(s) using the IT.  
Contactor and Starter User Manual (Publication No. 49400). Refer to the IT. QCPort System  
Install and Planning Guide (Publication No. MN05001002E) for more information on how to  
size the power supply for the QCPort system.  
The power for the Eatons Cutler-Hammer Intelligent Technologies (IT.) Electromechanical  
Starter must be connected to the Intelligent Technologies (IT.) Electromechanical Starter  
terminal, as illustrated in Figure 3.  
To Starter  
+
24V DC  
Optional  
E-Stop  
To QSNAP  
Figure 3: Starter Interface Connection  
Pub. No. MN05001001E  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
CAUTION  
Only apply 24V DC to the QSNAP. Use of any other voltage may  
result in personal injury, property damage and damage to the  
QSNAP.  
Pub. No. MN05001001E  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Operation  
This section provides details about the following features and aspects of QSNAP operation:  
 
 
 
 
 
 
Out of boxoperation  
Typical application  
Enhanced features  
Input/output data  
Status LED  
Truth table  
“Out of Box” Operation  
When the QSNAP is properly installed and has a properly congured Group ID, as per the  
Installationsection, the following default data lists will be presented to the system for use  
by a gateway.  
For further information on the meaning of the terms in the assemblies, see the Enhanced  
Featuressection on Page 10.  
Table 6: Default Input Data from QSNAP  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
3-Phase Average RMS Current LSB  
3-Phase Average RMS Current  
3-Phase Average RMS Current  
3-Phase Average RMS Current MSB  
% Thermal Capacity LSB  
Byte 0  
Byte 1  
Byte 2  
Byte 3  
Byte 4  
Byte 5  
Byte 6  
Byte 7  
% Thermal Capacity MSB  
Fault/Warning Codes LSB  
Fault/Warning Codes MSB  
Reserved Warning Faulted  
Local  
Control  
Resetting Permissive Running Running Byte 8  
2
1
Table 7: Default Output Data to QSNAP  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reserved Reserved Local  
Local/  
Remote  
Fault  
Reset  
Permissive Run 2  
Run 1  
Byte 8  
Control  
Pub. No. MN05001001E  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Typical Application  
The following gure illustrates a typical QSNAP application, where a single QSNAP is  
connected to one motor controller and where the motor controllers are distributed  
throughout QCPort. The subnet is then being controlled by a PC or PLC, which scans the  
D77D-DNA DeviceNet Adapter, retrieving the QSNAPs control and monitoring information.  
D77D-DNA D77A-IO  
D77A-IO  
IT. Starters with QSNAPs  
To Control  
PC or PLC  
24V DC IT.  
Supply  
QCPort  
Figure 4: Typical QSNAP Application  
Note: Such an application has more devices on QCPort than are shown in this illustration,  
such as drives and user interface units.  
Pub. No. MN05001001E  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Enhanced Features  
The QSNAP offers a variety of enhanced features, including: settable warnings, current  
threshold warning, underload warning and reset. To help diagnose an application, a fault  
queue is provided to view the last ve faults.  
Refer to the following two tables for denitions of the QSNAP Enhanced Features and  
Threshold Features.  
Table 8: Standard Features  
Fault  
Definition  
Phase Current  
A phase current unbalance trip will occur if one or two of the line currents are  
Unbalance/Phase Loss 40 60% or less of the remaining line(s) for longer than 10 seconds.  
A phase loss trip will occur with a load current of at least 75% of the minimum  
FLA if one of the two input line voltages is lost, with the line current going to  
zero for longer than 10 seconds.  
Thermal Overload  
While the motor is running and depending on the FLA and trip class settings,  
when the FLA is exceeded for a period of time (depending on the trip class  
setting), a thermal overload trip will occur. For more information on this  
feature, see the IT. Contactor and Starter User Manual (Publication No. 49400).  
Table 9: Enhanced Features  
Fault  
Definition  
Ground Fault  
With the addition of a Ground Fault module, the QSNAP will trip when the  
module detects a ground fault. To set the level of the trip, a setting is adjusted  
on the Ground Fault Module. The Ground Fault Module is connected to the  
QSNAP through the Auxiliary opening on the face of the QSNAP.  
Underload Warning  
While the motor is running, a warning will be activated when the current falls  
below a user settable % of FLA.  
Current Threshold  
Warning  
While the motor is running, a warning will be activated when the current rises  
above a user settable % of FLA.  
Note: The threshold values for Thermal Overload and Phase Current Unbalance can not be  
modied.  
Pub. No. MN05001001E  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Input/Output Data  
The QSNAP offers a standard data list (shown below) for default operation. The list is  
congurable with data contained within Table 21 in Appendix A: QSNAP Parameters, using  
the CH Studio application.  
Input Data  
Use Tables 10 and 11 when setting up the QSNAP input data.  
Table 10: Input Assembly Data Definitions  
Data  
Description  
Faulted/Trip  
Warning  
The motor controller is faulted or tripped  
The motor controller has a warning of an impending trip  
The rst motor controller is running  
Running 1  
Running 2  
The second motor controller is running  
Permissive  
Resetting  
The motor controller run/stop permissive  
Motor controller is in the process of resetting a fault  
% thermal capacity of the motor from 0 to 100%  
Average RMS current of the motor (0.000A)  
Thermal Capacity  
RMS Average  
Current  
Fault Codes and  
Warning Codes  
Valid fault and warning codes are:  
0
No Fault  
1
General Fault  
2
Firmware Fault  
3
Interdevice Communication Fault  
Control Voltage Low Fault  
Control Device Overtemperature Fault  
Motor Phase Loss Fault  
Motor Phase Imbalance Fault  
Motor Ground Fault  
4
5
6
7
8
9
Motor Underload Fault  
Motor Overcurrent Fault  
Motor Bypass Failure Fault  
Motor Thermal Pile Fault  
Control Device Test Fault  
Current Threshold Warning  
Underload Warning  
10  
13  
14  
15  
40000  
40001  
40002  
40003  
Control Device Overtemperature Warning  
Overload Warning  
Pub. No. MN05001001E  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Table 11: Default Input Data  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
3-Phase Average RMS Current LSB  
3-Phase Average RMS Current  
3-Phase Average RMS Current  
3-Phase Average RMS Current MSB  
% Thermal Capacity LSB  
Byte 0  
Byte 1  
Byte 2  
Byte 3  
Byte 4  
Byte 5  
Byte 6  
Byte 7  
% Thermal Capacity MSB  
Fault/Warning Codes LSB  
Fault/Warning Codes MSB  
Reserved Warning Faulted  
Local  
Control  
Resetting Permissive Running 2 Running 1 Byte 8  
Output Data  
Use Tables 12 and 13 when setting up the QSNAP output data.  
Table 12: Default Output Data  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
Reserved Reserved Local  
Local /  
Remote  
Fault  
Reset  
Permissive Run 2  
Run 1  
Byte 8  
Control  
Table 13: Output Assembly Data Definitions  
Data  
Description  
Run 1  
Energize the rst starter when Permissive is 1  
Energize the second starter when Permissive is 1  
Reset the fault  
Run 2  
Fault Reset  
Permissive  
Starter Permissive, O Stops the starter, I Enables to run the starter  
Pub. No. MN05001001E  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Status LED  
The status LED is located on the lower right of the QSNAP as pictured in Figure 1: QSNAP  
Features. The LEDs status changes depending on the state of the QSNAP.  
The following table lists the IT. QSNAP LED statuses and describes the meaning of each state.  
Table 14: Status LED  
State  
LED Behavior  
No Power  
OFF  
Power-Up Routine  
OFF CRC corrupt  
Waiting for a member ID,  
power-up OK (mostly off)  
Received a member ID,  
off-line (slow blink)  
On-line (mostly on)  
Faulted (fast blink)  
Identify device (burst)  
Truth Table  
Table 15: QSNAP Truth Table  
Fieldbus Inputs  
Old State  
Run 1 Run 2 Reset Event  
New State  
Action  
FAULTED  
OFF  
0
1
0
1
1
1
1
1
0
1
0
0
0
1
1
1
1
1
0
1
0
1
1
RESET  
NONE  
RUN 1  
RUN 2  
RUN 2  
RUN 1  
OFF  
OFF  
FAULT = 0  
NONE  
READY = 1  
OFF  
RUNNING 1 RUNNING 1 = 0  
RUNNING 2 RUNNING 2 = 0  
RUNNING 1 NONE  
OFF  
RUNNING 1  
RUNNING 2  
RUNNING 1  
RUNNING 2  
RUNNING 1  
RUNNING 2  
RUNNING 1  
RUNNING 2  
RUNNING 2 NONE  
RUN 1 removed RUNNING 2 RUNNING 1 = 0, RUNNING 2 = 1  
RUN 2 removed RUNNING 1 RUNNING 1 = 1, RUNNING 2 = 0  
FAULT  
OFF  
OFF  
RUNNING 1 = 0 READY = 0  
RUNNING 2 = 0 READY = 0  
FAULT  
WARNING  
WARNING  
RUNNING 1 RUNNING 1 = 1 WARNING = 1  
RUNNING 2 RUNNING 2 = 1 WARNING = 1  
= state not important  
1 = state true (energized)  
RUNNING 1 = Run/FWD/SLOW  
RUNNING 2 = REV/FAST  
0 = state false (de-energized)  
WARNING = Running Current > FLA but not tripped  
FAULT = GND FLT and/or OL TRIP  
Pub. No. MN05001001E  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Configuration  
The only conguration that is necessary for normal operation of the QSNAP is setting the  
Group ID and SW1 positions A and B, as described in the Installationsection. However, the  
QSNAP offers a variety of enhanced features. When these features are required, use the CH  
Studio application or a tool that can read an EDS le to perform the conguration.  
Using CH Studio  
The CH Studio software application is designed for programming and conguring industrial  
automation systems. The application simplies the monitoring and conguration of entire  
networks as well as the enhanced features of individual IT. communicating devices within  
those networks.  
CH Studio takes advantage of the Windows graphical interface to present a suite of tools that  
is easy to learn and efcient to use, while meeting the requirements for developing complex  
network congurations.  
CH Studio performs the following conguration functions for DeviceNet and QCPort  
networks:  
 
 
 
 
 
 
Discover network devices  
Display device properties  
Monitor and congure network devices  
Save existing network congurations  
Congure networks off-line  
Congure devices off-line  
Pub. No. MN05001001E  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Installation  
Set the Group ID  
The Group ID refers to the logical QCPort group to which the QSNAP belongs. For further  
information on the explanation of Group ID and the system conguration, see the IT. QCPort  
System Install and Planning Guide (Publication No. MN05001002E).  
The Group ID and SW1 A and B DIP switches are located at the upper right of the QSNAP, as  
illustrated in Figure 5: Group ID Setting. CH Studio can view the settings for the Group ID, but  
cannot be used to modify them.  
Move the DIP switches to ON/OFF positions to create the Group ID. Moving a DIP switch to  
the right is ON and moving the switch to the left is OFF. The Group ID is in binary with the  
major units numbered to the right of the switch on the side label. Adding up the major units  
set to ON determines the Group ID of the QSNAP.  
Example: To set the Group ID to 25, start from the top (or 32) and set the switches to OFF, ON,  
ON, OFF, OFF, ON (16+8+1=25).  
32  
16  
8
Group  
ID  
4
2
1
A
SWI  
B
OFF (0)  
Figure 5: Group ID Setting  
When a gateway is present and presenting the QSNAP as remote IO, each device on the  
QCPort must have a unique Group ID. If any two like QCPort devices have the same Group ID,  
those devices will go off-line. Refer to the appropriate gateway install manual for information  
on the data packet construction for that eldbus (IT. DeviceNet Adapter Installation and User  
Manual, Publication No. MN05004002E).  
Once the Group ID is set, a power cycle is not required; after ve seconds of inactivity of the  
switches, the change takes effect. The Status LED indicates if the QSNAP is properly  
congured; the LED is located on the lower right of the QSNAP, as illustrated in Figure 6:  
QSNAP with 54 mm IT. Starter. For more information on the LED, see Operation.”  
Pub. No. MN05001001E  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
SW1 Settings  
SW1 is used to set the existence of the second Aux contact and the external ground fault.  
Table 16: SW1 Settings  
SW1 Position  
Event  
A
B
0 = no second Aux installed, 1 = second Aux installed  
0 = no ground fault installed, 1 = ground fault installed  
Mount the IT. QSNAP to the Starter  
The IT. QSNAP is designed to be installed in the auxiliary contact locations of the IT. family of  
starters as illustrated in Figure 6. On all starters, one or more auxiliaries can be used along  
with the QSNAP. Table 17 lists starters and indicates the number of available auxiliary  
locations for each.  
Table 17: Starter Size/Available Auxiliary Locations on Mounted QSNAP  
Number of Available Auxiliary Locations  
Starter Frame Size (mm)  
when Center Mounted  
45  
1 single  
54  
1 single or 1 dual  
2 single or 2 dual  
2 single or 2 dual  
2 single or 2 dual  
76  
105  
140  
Figure 6: QSNAP with  
54 mm IT. Starter  
Pub. No. MN05001001E  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Use the following steps and the illustration in Figure 7 to mount the QSNAP.  
1. Align both the QSNAP feet with the auxiliary contact mounting slots on the starter, as  
illustrated in the gure.  
Recommendation: Use the middle mounting auxiliary contact on the contact block when  
mounting the QSNAP.  
2. When the QSNAP is aligned, insert the feet into the detents and slide the QSNAP  
towards the overload until a clickis heard. This ensures that the QSNAP is mounted  
securely to the starter.  
1. Align and  
Insert  
2. Slide  
Figure 7: QSNAP Alignment and Mounting  
Note: To remove the QSNAP, press the PUSHtab protruding from the QSNAP while sliding  
the QSNAP up and pulling away from the contactor block, as illustrated in Figure 8.  
1. Slide  
2. Pull  
Away  
Figure 8: QSNAP Removal  
Pub. No. MN05001001E  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Wire the IT. QSNAP to the Starter  
The QSNAP is connected to the IT. starter using a factory-provided jumper with an RJ-45 plug  
on one end and a pigtail on the other. The pigtail is color coded to facilitate accurate  
connection to the overload terminal block. Refer to the following gure and table when  
wiring the terminal block.  
RJ-45 Plug  
1
1
1
Figure 9: Jumper and RJ-45 Plug  
Table 18: Terminal Block Wiring  
Starter  
RJ-45  
GND  
1
2
3
4
5
6
7
8
+24  
P
F
R
1
2
3
Use the following steps and illustrations to install the jumper.  
1. Once the jumper is wired, insert the terminal block into the overload and the RJ-45  
connector into J3 on the QSNAP as illustrated in Figure 10: Jumper Installation.  
QSNAP  
Jumper  
IT. Starter Terminal Block  
Figure 10: Jumper Installation  
Pub. No. MN05001001E  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
2. To lock the starter interface to the overload, rotate the orange locking tabs until the tab  
is locked into the slots in the overload. Use Figure 11 for information on which way to  
rotate the locking tabs.  
Note: Refer to the IT. Contactor and Starter User Manual (Publication No. 49400) for more  
information on locking and unlocking the terminal block to the starter.  
Connect the QSNAP to QCPort  
The connection to QCPort consists of using the QCPort interconnect jumper from the second  
port of the upstream device and connecting it to J1 on the QSNAP. The downstream QCPort  
device then connects to J2 on the QSNAP as in Figure 11: QCPort Connection. Use the  
following wiring diagram and illustration to connect the QSNAP to QCPort.  
Figure 11: QCPort Connection  
1
1
1 +24  
2 G  
3 B  
4 A  
5 +24  
6 G  
Figure 12: QCPort Wiring Diagram  
Use one of the pre-manufactured cables for connecting between QCPort devices. If a custom  
cable is to be made, follow the guidelines for cable specications and connector types listed  
in IT. QCPort System Install and Planning Guide (Publication No. MN05001002E).  
Pub. No. MN05001001E  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Troubleshooting and Maintenance  
Renewal Parts  
The renewal parts for the QSNAP are shown in the following table.  
Table 19: QSNAP Renewal Parts  
Description  
Part Number  
J3 Jumper  
Consult Factory  
Consult Factory  
Consult Factory  
Consult Factory  
Consult Factory  
Starter Interface  
Auxiliary Contact  
Ground Fault Detector  
Auxiliary Plug  
Troubleshooting  
Table 20: Troubleshooting  
Observation  
Possible Cause/Corrective Action  
IT. starter attempts to  
energize when RUN is  
commanded but will not  
stay in  
Check 24V DC coil power supply.  
IT. starter will not energize Control terminal block is not seated or connected properly on overload or  
customer wiring.  
Check 24V DC control power supply.  
Verify that the permissive bit is = 1.  
Check J3 wiring.  
Make sure there is not a trip.  
Reversing starter will not  
energize  
Unit already running in forward. The units are electrically and  
mechanically interlocked.  
Check J3 wiring.  
Reversing starter will not  
energize but forward does  
Check J3 wiring.  
Reversing interlock is jammed.  
Check J3 wiring.  
IT. starter automatically  
energizes on power-up  
Pub. No. MN05001001E  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Appendix A: QSNAP Parameters  
Refer to the following table when conguring the QSNAP.  
Table 21: Configuration Parameters  
Number Parameter  
Length  
Units  
1
Cong Data  
14  
2
2
1
1
1
2
16  
2
2
0
0
0
4
1
1
2
2
1
1
2
1
1
2
1
2
1
1
2
Conguration CRC check  
Node ID  
3
4
QCPort mode  
5
Baud Rate  
6
Slave Address  
7
Production Dest  
8
Device ID Tag  
9
Prod Int  
10  
11  
12  
13  
32  
33  
34  
37  
38  
43  
44  
46  
51  
52  
54  
55  
56  
57  
58  
Cons Int  
Parameter List  
Production List  
Consumption List  
Overload Trip FLA Value  
Overload Trip Class Value  
Percent Initial Torque  
Amps  
Class  
%
Motor Start Ramp Time  
Motor Stop Ramp Time  
Current Threshold Warning Threshold  
Current Threshold Warning Threshold  
Current Threshold Warning Debounce  
Motor Underload Warning Level  
Motor Underload Warning Level  
Motor Underload Warning Debounce  
Motor Ground Fault Enable  
Motor Ground Fault Debounce Time  
Motor Ground Fault Inhibit From Start Delay Enable  
Motor Ground Fault Inhibit From Start Delay  
mS  
mS  
En/Dis  
%
mS  
En/Dis  
%
mS  
En/Dis  
mS  
En/Dis  
S
Pub. No. MN05001001E  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Table 22: Data Parameters  
Number  
Parameter  
Units  
Length  
11  
12  
13  
14  
15  
16  
18  
22  
23  
24  
26  
Motor Control  
1
1
2
1
1
1
4
2
2
2
2
Motor Control Status  
Motor Control Faults  
Button State  
LED State  
ASCII Text  
RMS AC Current  
Control DC Voltage  
Thermal Pile Percentage  
Temperature Deg C  
Fault Quene  
Amps  
Amps  
Volts  
%
Hz  
Pub. No. MN05001001E  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Intelligent Technologies (IT.) Publications and Support  
Table 23: IT. Publications  
Publication  
Description  
MN05002001E  
MN05001002E  
MN05001001E  
IT. D77A- IO Module Products Installation and Users Manual  
IT. QCPort System Install and Planning Guide  
IT. QCPort Starter Network Adapter Product (QSNAP) Installation  
and Users Manual  
Pub 4960  
IT. Overload Relay Setup and Troubleshooting Guide  
IT. Overload Relay Quick Setup Guide  
Pub 49601  
MN05004001E  
IT. DeviceNet Starter Network Adapter Product (DSNAP) Installation  
and Users Manual  
MN05004002E  
Pub 49907  
IT. DeviceNet Adapter Installation and User Manual  
Intelligent Technologies S751 Soft Starter User Manual  
For copies of these and other publications contact the Literature Fulllment Center at  
1-800-957-7050.  
Pub. No. MN05001001E  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intelligent Technologies (IT.) QSNAP  
February 2002  
Pub. No. MN05001001E  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Eaton’s Cutler-Hammer Aftermarket Services  
Technical/telephone support  
Resident service engineers in major trading centers  
Factory repair services  
Warranty administration  
Equipment modication and upgrading services  
Training seminars  
For additional information on this  
product, please call our Customer  
Support Center at:  
1-800-356-1243  
For service or start-up assistance  
24 hours/day, 7 days/week,  
please call:  
1-800-498-2678  
A response network that gives new meaning to customer service  
Personalized  
Comprehensive  
Professional  
Eaton Corporation  
Cutler-Hammer business unit  
1000 Cherrington Parkway  
Moon Township, PA 15108-4312  
USA  
tel: 1-800-525-2000  
© 2002 Eaton Corporation  
All Rights Reserved  
Publication No. MN05001001E  
February 2002  
Printed in USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion Cassette Player AX410 User Manual
Clarion CD Player DXZ275MP User Manual
Craftsman Snow Blower 536881851 User Manual
Crate Amplifiers Stereo Amplifier DXJ112 User Manual
Curtis Clock Radio KCR2606 User Manual
Eaton Electrical Heat Pump PVE12 User Manual
Fisher Paykel Washer GWL12 User Manual
GE Air Conditioner ABN08 User Manual
GE Monogram Refrigerator ZISS480NXSS User Manual
Generac Power Systems Portable Generator 004987 2 005396 0 User Manual