IMPORTANT SAFETY INSTRUCTIONS
The lightning flash with an arrowhead symbol within an
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
1
2
3
4
5
6
7
8
9
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with a dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10 Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the
apparatus.
11 Only use attachments/accessories specified by the manufacturer.
12
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13 Unplug this apparatus during lightning storms or when unused for long periods of time.
14 Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
Warning!
•
To reduce the risk of fire or electrical shock, do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids,
such as vases, are placed on the equipment.
•
•
•
•
This apparatus must be earthed.
Use a three wire grounding type line cord like the one supplied with the product.
Be advised that different operating voltages require the use of different types of line cord and attachment plugs.
Check the voltage in your area and use the correct type. See table below:
Voltage
Line plug according to standard.
110-125V
220-230V
240V
UL817 and CSA C22.2 no 42.
CEE 7 page VII, SR section 107-2-D1/IEC 83 page C4.
BS 1363 of 1984. Specification for 13A fused plugs and switched and un-switched socket outlets.
•
•
•
•
•
•
This equipment should be installed near the socket outlet and disconnection of the device should be easily accessible.
To completely disconnect from AC mains, disconnect the power supply cord from the AC receptable.
The mains plug of the power supply shall remain readily operable.
Do not install in a confined space.
Do not open the unit - risk of electric shock inside.
Service
There are no user-serviceable parts inside. All service must be performed by qualified personnel.
EMC/EMI
This equipment has been tested and found to comply with the limits for a Class B Digital device, pursuant to part 15 of the FCC rules.
These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful inter-
ference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on. The
user is encouraged to try to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution:
You are cautioned that any change or modifications not expressly approved in this manual could void your authority to operate this equipment.
For the customers in Canada:
This Class B Digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations ICES-003.
Cet appareil numérique de la classe B respecte toutes les exigences du Réglement sur le matériel brouilleur du Canada.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
a
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE OF CONTENTS
The AIR REMOTE
Basics
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Important Safety Instructions . . . . . . . . . . . . . . .a
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . .3
Quick Setup Reference . . . . . . . . . . . . . . . . . . .4
Operational Overview . . . . . . . . . . . . . . . . . . . . .6
Setups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
The AIR SOFT
Setting up of the AIR SOFT . . . . . . . . . . . . . . .46
Operating AIR SOFT . . . . . . . . . . . . . . . . . . . .46
Introduction
This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . .14
The Product Concept . . . . . . . . . . . . . . . . . . . .14
Appendix
Miscellaneous
Miscellaneous Technical Comments . . . . . . . .51
Reset procedure . . . . . . . . . . . . . . . . . . . . . . . .51
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
System Description
The Master/Slave Concept . . . . . . . . . . . . . . . .14
The Master Unit . . . . . . . . . . . . . . . . . . . . . . . .15
The Slave & Sub Units . . . . . . . . . . . . . . . . . . .15
Initializing Network . . . . . . . . . . . . . . . . . . . . . .15
Remote Control . . . . . . . . . . . . . . . . . . . . . . . .15
Common Features . . . . . . . . . . . . . . . . . . . . . .15
Rear Panel Description . . . . . . . . . . . . . . . . . . .16
Technical Specifications
Technical specifications for all models . . . . . . .53
Delay in System . . . . . . . . . . . . . . . . . . . . . . . .56
Error messages . . . . . . . . . . . . . . . . . . . . . . . .56
Certificate of Conformity . . . . . . . . . . . . . . . . . .57
Preset list . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Operation
The AIR Display . . . . . . . . . . . . . . . . . . . . . . . .17
Parameter Description . . . . . . . . . . . . . . . . . . .18
Optimizing Your Setup
Placing the Monitors . . . . . . . . . . . . . . . . . . . . .21
Checking Monitor Placement . . . . . . . . . . . . . .23
Calibrating Main Monitors . . . . . . . . . . . . . . . . .24
X-Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Placing the Subwoofer . . . . . . . . . . . . . . . . . . .26
Checking Subwoofer Placement . . . . . . . . . . .27
Calibrating the subwoofer
with the Main Monitors . . . . . . . . . . . . . . . . . . .28
Bass-management . . . . . . . . . . . . . . . . . . . . . .28
Background Information
Acoustics . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Sabines formula . . . . . . . . . . . . . . . . . . . . . . . .31
Absorbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Diffusers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Standing waves
Standing Waves . . . . . . . . . . . . . . . . . . . . . . . .33
Room Modes . . . . . . . . . . . . . . . . . . . . . . . . . .34
Comb Filtering . . . . . . . . . . . . . . . . . . . . . . . . .37
Rear Wall Cancellation . . . . . . . . . . . . . . . . . . .39
The Subwoofer . . . . . . . . . . . . . . . . . . . . . . . . .40
Bass Management . . . . . . . . . . . . . . . . . . . . . .40
The LFE Channel . . . . . . . . . . . . . . . . . . . . . . .41
Delaying Monitors . . . . . . . . . . . . . . . . . . . . . . .42
Line Up & Calibration . . . . . . . . . . . . . . . . . . . .43
How To Measure the Sound Pressure . . . . . . .43
TC Electronic, Sindalsvej 34, DK-8240 Risskov
AIR
English version
Rev 1.61 - SW 1.60
Prod. No. 606104919
3
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK SETUP REFERENCE
This page is a quick guide on how to connect different setups. Connections must be made exactly as illustrated.
Detailed descriptions of the setups can be found on pages 7-13.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
QUICK SETUP REFERENCE
Important !
• One specific Master monitor must be set as System Controller.
(see setup illustrations above)
• To set a Master monitor as System Controller the TC LINK button on the
rear panel must be left out.
• The TC LINK button on all other Master monitors must be set to In position.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATIONAL OVERVIEW
Parameter structure accessible via the AIR monitor set as System Controller
Empty
Custom
Main Display
“Serial No” L Front
Volume -50.0 dB
Stereo analog
Stereo digital
5.1 analog
5.1 digital
ENTER
*Select Task
No task
L Front
R Front
Center
(C) SUB
L Sur
R Sur
6.1 analog
6.1 digital
5.3 analog
5.3 digital
*Select Mode
Off
Bass Management
X-over Off
X-over 50Hz
X-over 80Hz
X-over Ext 50Hz
X-over Ext 80Hz
X-over THX 80Hz
X-over SC 120Hz
ENTER
5.1 digital/6 Master
C Sur
L SUB
R SUB
ENTER
ENTER
L Chain
R Chain
L Inner
Setup Menu
Setup
“xxxx”
ENTER
R Inner
Custom 1-4
Set monitor
tasks
*Select AIR
Master “xxxx”
ENTER
ENTER
AIR BASE
Pink Noise Off/On
Calib
Rel. Lev
LFE LP
0.0dB
-5.0dB
On/Off
*Select clock
BNC Input On
BNC Input Off
External clock
BNC Sync “xxx”
LFE Gain 0 to +14dB
Polarity
Phase
0/180deg
0-180deg
Sensitivity A-Input
+9dBu, +15dBu,
+21dBu, +27dBu
Input Sensitivity
A-Input Gain +27dB
ENTER
ENTER
AIR
Pink Noise Off/On
Calib
Rel. Lev
Position: Neutral
0.0dB
-5.0dB
*Select AIR
Master “xxxx”
ENTER
EXIT
Calibrate monitor
(press
Wall
ENTER)
Corner
Console
C. Wall
C. Corn
0.0dB
Accept to clear
network setup
Clear setup for
entire network
ENTER
Bass
Treble
0.0dB
Recall Preset
Preset locations:
User #1 to #15
Factory #16 to 32
*Select preset
ENTER
ENTER
1
User
*Select preset
User
Store locations are:
Store Preset
Utility Menu
1
User
#1 to #15
Duration before
Standby: 30min
Powersave: 3h
Backlight: on
Autosave volume:
off
15min, 30min,1h, 1.5h, off
1h, 1.5h, 2.5h, 3h, 5h, off
on, auto, off
ENTER
ENTER
off, on
6
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
Stereo Setup
This illustration shows how to connect a standard
stereo setup.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
• Left monitor receives both Left and Right Input signal.
• Right monitor receives audio via the TC-LINK RJ-45
connection.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
Stereo Setup with mono Sub(s)
This illustration shows how to connect a stereo setup
with 1 Sub.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
To set a Master
monitor as
System Controller
the TC Link
• Left monitor receives both Left and Right Input signal.
• Right monitor and Sub receives audio via the
TC LINK RJ-45 connections on the Left monitor.
• With no Bass-management, no signal is sent to the Sub.
• With Bass-management activated, Low Frequency
information from Left and Right channels below the set
Cross-over frequency is extracted and fed to the Sub.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
button on the rear
panel MUST be in
out-position.
Stereo Setup with stereo Subs
This illustration shows how to connect a stereo setup
with SUBs.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
To set a Master
monitor as
System Controller
the TC Link
• Left monitor receives both Left and Right Input signal.
• Right Monitor and Subs receive audio via the TC LINK
RJ-45 connection as illustrated.
button on the rear
panel MUST be in
out-position.
• With no Bass-management, no signal is sent to the Sub.
• With Bass-management activated, Low Frequency
information from Left and Right channels, below the set
Cross-over frequency, is extracted. Low frequency
information from the Left channel is distributed to L Sub
and Low Frequency information from the Right channel is
distributed to the Right Sub.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
5.1 Digital Setup
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
This illustration shows how to connect a 5.1 digital
setup
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
• Left monitor receives both Left and Right Input signal.
Right channel is fed via the TC -LINK RJ-45 connection
from the Left to Right.
• LS monitor receives both Left and Right Surround
channels. The RS channel is fed via the RJ-45
connection from LS to RS.
• Center monitor receives both Center and LFE channels.
The LFE monitor is fed via the RJ-45 connection from
Center to LFE.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
5.1 Analog Setup
This illustration shows how to connect a 5.1 analog
setup
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
• Left monitor receives both Left and Right Input signal.
Right channel is fed via the TC -LINK RJ-45 connection
from the Left to Right.
• LS monitor receives both Left and Right Surround
channels. The RS channel is fed via the RJ-45
connection from LS to RS.
• Center monitor receives both Center and LFE channels.
The LFE monitor is fed via the RJ-45 connection from
Center to LFE.
• With no Bass-management active the Sub will play only
the LFE channel.
• With Bass-management activated Low Frequency
information from the 5 main channels is extracted and
distributed to the Sub where it is summed with the LFE
channel.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
The setups will ONLY operate correctly if connected
according to the illustrations!
8
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
5.3 Digital Setup
This illustration shows how to connect a 5.3 Digital
setup
• Center is set as System Controller by leaving out the TC
Link button on the rear panel.
• Left monitor receives both Left and LS signal. The LS
monitor is fed via the TC LINK RJ-45 connection form
Left to LS.
• Center monitor receives both Center and LFE signal. The
LFE monitor is fed via the TC LINK RJ-45 connection
from Center to LFE.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• Right monitor receives both Right and RS signal. The RS
monitor is fed via the TC LINK RJ-45 connection from
Right to RS.
• With Bass-management “off” Left and Right Subs
receives no signal.
• With Bass management “on”:
- Low frequency information from Left and LS is
extracted and fed to Left Sub.
- Low frequency information from Right and RS is
extracted and fed to Right Sub.
- Low frequency information from Center is extracted,
summed with the LFE channel and fed to Center Sub.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
5.3 Analog Setup
This illustration shows how to connect a 5.3 Analog
setup.
Please see description on 5.3 Digital Setup above
regarding Bass-management but notice how to connect the
Analog signals:
• Left channel to Left Input on the Left monitor.
• Left Surround channel to Right Input on the Left monitor.
• Center channel to the Left Input on the Center monitor.
• LFE channel to the Right Input on the Center monitor.
• Right channel to the Left Input on the Right monitor.
• Right Surround channel to Right Input on the Right
monitor.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
The setups will ONLY operate correctly if connected
according to the illustrations!
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
6.1 Analog Setup
This illustration shows how to connect a 6.1 Analog
setup
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• Left is set as System Controller by leaving out the TC
Link button on the rear panel.
• Left monitor receives both the Left and Right signal. The
Right monitor is fed via the TC LINK RJ-45 connection
form Left to Right.
• Center monitor receives both Center and LFE signal. The
LFE monitor is fed via the TC LINK RJ-45 connection
from Center to LFE.
• Left Surround monitor receives both LS and RS signal.
The RS monitor is fed via the TC LINK RJ-45 connection
from LS to RS.
• The Center Surround monitor receives only Center
Surround signal.
• Center Chain: From software 1.10 it is possible to
connect one or more Center Chain monitors.
Channels must be connected as follows:
- Left channel to Left Input on Left monitor.
- Right channel to Right Input on Left monitor.
- Center channel to Left Input on Center monitor.
- LFE channel to Right Input on Center monitor.
- Left Surround channel to Left Input on Left Surround
monitor.
• With Bass-management “off” only the LFE signal is fed to
the Sub.
• With Bass-management activated, Low Frequency
information below the set Cross-over frequency from the
5 main channels is extracted and distributed to the Sub
where it is summed with the LFE channel.
- Right Surround channel to Right Input on Left
Surround monitor.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
5.1 Dig/6 - Master
This is a 5.1 digital setup with Bass Management as an
option. The setup requires one Master monitor with the
optional Digital AES/EBU Input Card installed, four
Slave monitors (or Masters set as Slave) and one Sub.
• Center monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• Center monitor receives all 6 channels on the three
AES/EBU connections.
- Center and LFE on the monitors Digital IN connection.
- Left and Right on the I/O cards Digital IN no. 2.
- LS and RS on the I/O cards Digital IN no. 3.
• Right, Left, Sub, LS and RS receives signal via TC LINK
RJ-45 connections from the Center Master monitor.
• Clock MUST be sent on the AES connection feeding
Center/LFE channels (or on BNC).
• With Bass-management “off” only the LFE signal is fed to
the Sub.
• With Bass-management activated, Low Frequency
information below the set Cross-over frequency from the
5 main channels is extracted and distributed to the Sub
where it is summed with the LFE channel.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
Stereo Setup With Chains on L & R
This illustration shows how to connect a stereo setup
with chains on Left and Right.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
The chained monitors are fed with the same signal as
the front L&R monitors. This the type of setup you
would use when you wiish to be able to alternate
between a set of main- and nearfiels -monitors.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
• Left monitor receives both Left and Right Input signal.
• Right monitor receives audio via the TC-LINK RJ-45
connection.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
Other “Chained” Setups
From software 1.10 the available setups with “chain” option
is: 5.1, 6.1 and 5.3 for analog and digital and well as 5.1/6
master (digital only).
The installed option card will limit the choises of setups
presented on the speakers. If the AES/EBU option card is
installed, the default digital Input will become Input 1 on the
option card.
• Left Surround monitor receives both LS and RS signal.
The RS monitor is fed via the TC LINK RJ-45 connection
from LS to RS.
• Left Inner monitor receives both L Inner and R Inner
signal. The R Inner monitor is fed via the TC LINK RJ-45
connection from L Inner to R Inner.
• With Bass-management activated Low Frequency
information from the 5 main channels is extracted and
distributed to the Sub where it is summed with the LFE
channel. With Bass-management enabled, Low
Frequency information is not extracted for the Left and
Right Inner monitors.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
Analog connections
• Left channel to Left Input on Left monitor.
• Right channel to Right Input on Left monitor.
• Center channel to Left Input on Center monitor.
• LFE channel to Right Input on Center monitor.
• Left Surround channel to Left Input on Left Surround
monitor.
• Right Surround channel to Right Input on Left Surround
monitor.
• Left Inner channel to Left Input on Left Inner monitor.
• Right Inner channel to Right Input on Right Inner monitor.
7.1 Analog/Digital setup
Digital
• Left is set as System Controller by leaving out the TC
Link button on the rear panel.
• Left monitor receives both the Left and Right signal. The
Right monitor is fed via the TC LINK RJ-45 connection
form Left to Right.
• Center monitor receives both Center and LFE signal. The
LFE monitor is fed via the TC LINK RJ-45 connection
from Center to LFE.
It is not possible to choose a 7.1 setup in the setup
menu; you need to choose either a 5.1 or 6.1
setup, and set up the Left Inner and Right Inner
speakers for ‘L Inner’ and ‘R Inner’ tasks respectively.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
5.1 Digital - 192 kHz
This is a 5.1 digital setup at 192kHz with Bass
Management as an option. The setup requires three
Master monitors with the optional Digital I/O card
installed, two Slaves and one Sub.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
• - Left monitor receives Left and Right Front channels.
- Center monitor receives Center channel and Sub.
- Left Rear monitor receives LS and RS channels.
• The Sub receives signal via TC LINK RJ-45 connections
from the Center Master monitor.
• Clock MUST be sent on the AES connection feeding
Center/LFE channels (or on BNC).
• With Bass-management “off” only the LFE signal is fed to
the Sub.
• With Bass-management activated, Low Frequency
information below the set Cross-over frequency from the
5 main channels is extracted and distributed to the Sub
where it is summed with the LFE channel.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
6.1 Digital - 192 kHz
This is a 6.1 digital setup with Bass Management as an
option. The setup requires four Master monitors with
the optional Digital I/O Card installed, two Slave
monitors (or Masters set as Slave) and one Sub.
• Left monitor is set as System Controller by leaving out
the TC Link button on the rear panel.
• - Left monitor receives both Left and Right Input signals.
- Right monitor receives signal via the TC LINK cable.
- Left Surround, receives both Left and Right surround
signals.
To set a Master
monitor as
System Controller
the TC Link
button on the rear
panel MUST be in
out-position.
- Right Surround, receives signal via the TC LINK cable.
- Center receives both Center and Sub signals.
- The Sub receives signal via the TC LINK cable.
- Center Surround receives Center Surround channel.
• Clock MUST be sent on the AES connection feeding
Center/LFE channels (or on BNC).
• With Bass-management “off” only the LFE signal is fed to
the Sub.
• With Bass-management activated, Low Frequency
information below the set Cross-over frequency from the
6 main channels is extracted and distributed to the Sub
where it is summed with the LFE channel.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SETUPS
5.3 Digital Setup
This illustration shows how to connect a 5.3 Digital
setup with Bass management as an option. The setup
requires three Master monitors with the optional Digital
AES/EBU I/O card installed, two Slave monitors (or
Masters set as Slave) and three Subs.
To set a Master
monitor as
System Controller
the TC Link
button on rear
panel MUST be in
out-position.
• Center is set as System Controller by leaving out the TC
Link button on the rear panel.
• Left monitor receives both Left and Left Surround signal.
The LS monitor is fed via the TC LINK RJ-45 connection
from Left to LS.
• Center monitor receives both Center and LFE signal. The
LFE monitor is fed via the TC LINK RJ-45 connection
from Center to LFE.
• Right monitor receives both Right and Right Surround
signal. The RS monitor is fed via the TC LINK RJ-45
connection from Right to RS.
• With Bass-management “off” Left and Right Subs
receives no signal.
• With Bass management “on”:
- Low frequency information from Left and LS is
extracted and fed to Left Sub.
- Low frequency information from Right and RS is
extracted and fed to Right Sub.
- Low frequency information from Center is extracted,
summed with the LFE channel and fed to Center Sub.
• The Remote, AIR Soft and AIR PC-IP can be connected
to any available TC LINK Out connection.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Having said that, many studios today are still working with
analog signals for monitoring - therefore an Analog Input
option is also provided.
This Manual
The latest manual revision is always available for
The revision number of this manual is located at the
bottom of page 4. Please compare to the revision
number of the manual available for download from our
web-site and download if newer.
The following section is an introduction to the concept
of the AIR systems. Detailed parameter explanations,
setup guides and calibration info are to be found in
later sections of this manual.
Break in
Your AIR monitors must be “run in” before optimal
performance is achieved. It is essential that the monitors
are not run at full level until after at least 24 hours of
moderate operation. Optimal performance is achieved after
about one week of operation at moderate levels.
The Master/Slave Concept
Two physically different units exist for each model.
A Master unit able to:
- receive digital audio on AES connections
- receive analog audio (if an analog option card is
installed)
The Product Concept
- send and receive audio and control data via the
proprietary TC LINK connection.
The AIR monitor systems take a giant step forward in
near-field monitoring and Dynaudio & TC Electronic are
proud to present these systems. The AIR series include
switch mode amplification and power-supply and with the
addition of DSP and CPU, new possibilities are opened for
easy, convenient and precise central control of both audio
and setup-info.
Master Monitor Rear
• To set a Master Monitor as
System Controller the TC
LINK button on the rear
panel must be left out.
The networking possibilities will fit nicely into today's
applications and can be taken far into the future studio.
A brief overview of the new advantages with the concept:
• System integration and networking (total recall,
central control)
• Flexibility/adjustment possibilities (to the room,
personal liking etc.)
• Extreme precision. (Precise alignment of individual
monitors at the factory)
• Improved audio quality (from intelligent algorithms
and precision filters)
• One and only one of the Master units must be setup as
the System Controller. This is done by leaving out the TC
LINK button on the rear panel. (see above). Setting up a
system is done from the System Controller monitor.
You set up, set tasks and calibrate all connected
monitors in the entire system from the System Controller.
• A Slave unit is able to receive and distribute audio and
control data via the proprietary TC LINK connection.
• Direct Digital Reference (Digital Input)
Both AIR 6 and AIR 15 are Pro Audio rear-ported near-field
monitors and are excellent for both stereo and surround
setups in applications such as Music Recording/Mixing,
Post production, Film, Broadcast, Video-editing etc.
Slave Monitor Rear
Extreme Precision
The frequency response and timing of the woofer- and
tweeter signals of the AIR systems is controlled to a level of
precision only practically obtainable with DSP. Furthermore
the sensitivity of each individual loudspeaker driver is
measured in the line of production, and deviations are
compensated in the DSP software to 0.1dB steps.
Perfectly aligned monitors also give the so far unseen
advantage of interchangeability. In the unlikely case of a
monitor breakdown, a perfectly matching monitor can be
added instantly.
Audio signal from your studio is input to the Master
monitors only and the signal is distributed from here to the
connected Slave units through a proprietary Networking
protocol. It is worth noticing that a Master monitor acts
exactly as a Slave monitor when its TC LINK button is set
in “IN position.”
The networking capabilities, enables all monitors in a
setup, no matter if it is Stereo or Surround, Digital or
Analog to always be corresponding. This provides great
possibilities in terms of general control of the entire system.
As most productions do end up in a digital format these
days the AIR series allow monitoring of the "pure" Digital
signal. Simply feed the monitors directly with an AES/EBU
signal.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INTRODUCTION
Additional AIR Control units
The Master Unit
The Master unit distributes Audio and control data to the
respective Slave units connected.
Any additional control units, such as the optional AIR Soft
Remote or the AIR Remote, can be connected to any free
"Link" connector in the system. (see below)
Control data is transmitted via the System Controller, and
distributed to other monitors in the network.
System Controller, Master or Slave
To set up a Master unit to be either System Controller or
Master/Slave the LINK switch on the rear panel must be
set up correctly.
Remote Control
AIR monitor systems can be set up and controlled locally
via the Master monitor’s user-interface via the optional
remote control or from a PC/Mac.
Out:
The monitor operates as a System Controller
In:
AIR SOFT - Software Remote
The monitor operates as either:
- a regular Master with digital Inputs (analog Inputs are
only with the optional analog I/O card installed) or
- as a Slave unit.
Any parameter in the System Controller including the setup
parameters can be controlled via the “AIR SOFT”.
Additionally, software upgrades and installation of such can
be done via AIR SOFT.
I/O
Hardware Remote
The Master unit contains AES/EBU Input connectors and
three Link connectors carrying both audio and control data
to connected Slave units.
A simple remote level control, controlling the level of the
entire setup. Control data is transmitted to the Master unit,
and distributed from there ensuring that any monitor
hooked up, is set identically.
Connectors
1* AES/EBU - XLR
AIR PC-IP
2* Link RJ45 connectors
1* Link/Input RJ45 connector
1* Word Clock BNC sync
A software dedicated for the Advanced Installer. In addition
to the common parameters the AIR PC-IP software offers
Parametric EQ and various Parameter Lock functions.
Option slot
Two card types are currently available.
• An analog Input module giving the option of feeding a
Master unit with 2 analog Input signals.
• An AES Digital Input card giving the option of sending all
six channels in a 5.1 setup to one single Master monitor.
From there the signal is distributed to 4 slave monitors
and Sub via the TC LINK RJ-45 connections creating a
fully digital 5.1 setup.
Common Features
- for both the Master and Slave units
Advanced Condition Monitoring
For both the Master and the Slave units several protection
systems are included in the AIR monitors. This is to insure
both short term protection against large dynamic pulse
signals, but also to insure long term protection against
over-heating and thus permanent damaging the drivers.
Long term thermal protection
The Slave & Sub Units
Inside the amplifier module the temperature of the heat
sink is constantly monitored so any dangerous over-
temperature situations can be avoided - this is for
protection of the entire electronic module. Furthermore the
temperature of the tweeter voicecoil is calculated with
behavioral modeling of the tweeters thermal characteristics.
The Slave and Sub units contain one RJ45 Input connector
and one Link connector. Via the RJ45 Input connector the
Slave unit is supplied with audio and control data from the
Master unit. Via the RJ45 Link connector transmission to
additional monitors is possible.
Initializing Network
Beware
When the setup is powered up for the first time, the Master
unit scans the setup in order to determine the number of
monitors connected. Each monitor is recognized via a
unique serial number but can be renamed according to task.
After the initial scanning of the setup, the Master unit will
be re-scanning the setup every 5 seconds in order to
determine any change.
Power down procedure:
• In general, use the "sleep function" (Press and hold Exit
on System controller),
• System will automatically go into sleep mode after
2.5 hours.
• If you need to switch the system off on the mains switch
on rear panel, please make sure to turn down the global
volume and switch Slave monitors off before Master
monitors.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
REAR PANEL DESCRIPTION - MASTER
Master Unit - Analog I/O
• System Controller/Slave switch
Out-position :The monitor operates as a
System Controller
There can be only one System
Controller in a setup.
In -position:
The monitor operates as either a regular
Master or a Slave unit.
• RJ45 Link connections for downstream Slave units
• Option slot with analog I/O card installed. (optional)
• AES/EBU digital Input
• Word Clock BNC sync
• Power Input 100-240V
• Power On/Off - switch
Slave/Sub
• RJ45 Link connections for downstream Slave units
• Power Input 100-240V
• Power On/Off - switch
Optional Digital I/O card
Optional Digital I/O card
With this card installed in the Master Monitor option slot a
5.1 Digital/6 Master setup becomes an option.
Three AES/EBU connections (6 channels) can then be fed
to one Master monitor and distributed downstream.
For further information see “Setups”.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
THE AIR DISPLAY
Overload Indication
UP
EXIT
ENTER
DOWN
ENTER key
CURSOR UP/DOWN keys
The ENTER key has two main functions:
• To enter the menus currently displayed.
These keys are used for navigating and adjusting
parameter values.
• To set the displayed parameter in Edit mode.
When a parameter can be edited via the CURSOR keys a
“*” is set as the first character in front of the parameter.
Overload Indication LED
When this LED flashes the monitors built-in amp is driven
beyond max performance. A continuos overload will
activate the amp protection circuit and the monitor will be
shut down. The monitor can be reactivated after a short
period of cooling down.
EXIT key
The EXIT key is used to exit the current display and go to
previous menu level.
This situation will NOT damage the monitor in any way.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
PARAMETER DESCRIPTION
Basic operation in all menus
• Use ARROW keys to select value or submenu
• Use ENTER to enter menus or for confirmation, and to
activate
• Use EXIT to step to a higher level or to decline an
operation
• Values are marked with an “ * “ when they can be altered
via the ARROW keys
Main Display
The Main Display indicates the position of the monitor
(when set up) and the set volume for the monitor.
A “+” indicates that this specific Master Unit has been set
up to act as System Controller.
Bass Management
Bass management is possible in:
- Standard Stereo with 1 Sub
- Standard Stereo with 2 Subs
- 5.1 Analog
- 5.3 Analog
- 6.1 Analog
- 6.1 Digital - at 192kHz
- 5.3 Digital
- 5.1 Digital/6 Master
- 5.1 Digital - at 192kHz
Satellite monitors uses 2nd order Hi Pass filters to
attenuate frequencies below the set Cross-over frequency.
Subs use 4th order Low Pass filter to attenuate frequencies
above the set Cross-over frequency.
• Press ENTER to access the Select Mode
Off:
Bass Management is not activated. Only the LFE channel
is distributed to the Sub.
AIR PC-IP
Via AIR PC-IP and advanced Bass Management mode is
available. In this mode all filters (Satellite, Sub4 and Sub2)
can be controlled to suit demanding setups.
Cross-over frequencies:
Menu Name
Satellite filter
50 Hz
80 Hz
Off
Sub 2nd order
50 Hz
LFE = Sub
Sub 4th order
50 Hz
X-Over 50 Hz
X-Over 80 Hz
Extension 50 Hz
Extension 80 Hz
THX Sim 80 Hz
No
No
No
No
Yes
Yes
80Hz
80Hz
50 Hz
50 Hz
Off
80 Hz
80 Hz
80 Hz
Off
80 Hz
Small Cons 120 Hz * 120 Hz
80Hz
120 Hz
Note that the Extension 50 and 80Hz uses no Bass Management on satellite speaker thus playing full range.
* Small Cons - Small Consumer
18
Download from Www.Somanuals.com. All Manuals Search And Download.
PARAMETER DESCRIPTION
Setup
Setup Menu
• Press ENTER to enter select mode. Select mode is
indicated by “ * ”
• Press ENTER to access sub-menus
Set Monitor Task
• Press ENTER to confirm choice
For the System Controller - Master monitor to identify and
operate all monitors in the setup, each monitor must be
given one of the following tasks indicating function and
position.
Empty:
No selection
Custom:
For custom configurations.
• Press ENTER to access task options
• Use ARROW keys to select task
• Press ENTER to confirm selected task
Stereo analog:
Two monitor stereo setup with analog* Inputs selected.
Following tasks can be given:
Stereo Digital:
Two monitor stereo setup with digital Inputs selected.
- No task
- L Front
- R Front
- Center
- (C) Sub
- L Sub
- R Sub
- L Sur
- LsChain
- RsChain
- CsChain
- L Inner
5.1 Analog:
5.1 setup with analog* Inputs selected.
- R Inner
- CustMast
- CustSlaR
- CustSlaL
5.1 Digital
5.1 setup with digital Inputs selected.
- R Sur
- C Sur
6.1 Analog
5.1 Setup + Center surround on a separate channel gives
the 6.1 setup.
6.1 Digital
5.1 Setup + Center surround on a separate channel gives
the 6.1 setup.
5.3 Analog
Analog setup with 5 monitors and 3 subs
5.3 Digital
Digital setup with 5 monitors and 3 subs
* Analog Inputs are only available with an optional analog
card installed.
5.1 Digital/6 Master
5.1 Setup using one Master with optional Digital I/o card
installed, 4 slave monitors (or masters set as slave) and 1
sub.
External Clock
• Press ENTER to access sub-menus
BNC Sync On:
The monitor attempts to lock on the Word Clock BNC.
BNC Sync Off:
The monitor will attempt to lock on the AES Input.
Calibrate Monitor
• Press ENTER
• Select monitor to calibrate using the ARROW keys
• Press ENTER
19
Download from Www.Somanuals.com. All Manuals Search And Download.
PARAMETER DESCRIPTION
Parameters available for AIR 6 and AIR 15
Phase:
Pink Noise:
Range: 0-180°
Range: On/Off
To time-compensate if the Sub is not placed according to
the ITU 775 recommendations. There are individual Phase
settings for each of the Bass Management Cross-over
frequencies. Once set, these are stored as Global settings.
Calibrate:
Range: -6dB to +6dB
Level calibration of the selected monitor.
Clear Setup for entire network
Rel. Lev:
• Press ENTER and confirm with ENTER
Range: -40dB to 0dB
Relative preset volume for the selected monitor.
LFE channel - note
Please note that in general the LFE channel should be
mixed with +10dB headroom.
Room Position:
Neutral
If you are not able to boost your LFE monitor output from
your console, +10dB gain can be added on your AIR-Base
input. Most format encoders / decoders take the LFE boost
into account, meaning that you should leave the AIR-Base
LFE gain at 0dB when playing back a DTS or DOLBY
encoded material on your AIR system. LFE gain is set at
0dB in all factory presets, so if you need to add gain on
your AIR-Base please adjust this parameter and store the
new setting in a user preset location.
Wall
Corner
Console
C. Wall - Console Wall
C. Corn - Console Corner
Bass:
Range: -6dB to +6dB
Bass adjustment for the selected monitor
Recall
Treble:
Range: -6dB to +6dB
• Press ENTER and use ARROW keys to select presets
• Press ENTER to recall/load the selected preset
If no user-preset are stored on locations 1 to 4, presets 16
to 19 are loaded instead.
Treble adjustment for the selected monitor.
Parameters of AIR-Base subwoofers
Pink Noise:
Range: On/Off
Complete preset list is available in the appendix
section.
Calibrate:
Range: -18dB to +6dB
Level calibration of the selected monitor.
Store
• Press ENTER and select storage location using the
ARROW keys
Rel. Lev. - (Relative Level):
Range: -40dB to 0dB
Preset volume for the selected monitor relative to the
calibrated and global volume.
• Press ENTER again to store.
Storage location can be 1-15.
Parameter can be locked via the AIR PC-IP
software. When trying to change values on a
locked parameter the display reads “Locked”.
LFE Low Pass
Range: On/Off
Brickwall Limiter on the LFE channel attenuating
frequencies above 120Hz.
LFE Gain
Range: -6 to +8dB
With this parameter you can boost the acoustic gain of the
LFE channel.
Polarity
Range: 0 or 180º
If the Subwoofer is correctly placed, setting the Phase
Reverse parameter at 180º should result in a full Phase
cancellation at the set Cross -over frequency. If this is not
the case - the Delay parameter should be adjusted.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
PLACING THE MONITORS
This manual section is split into two. The first part is a direct guide on how to optimize your listening facilities to
ensure optimal performance of your AIR monitor system. The second part contains In Depth explanations and
background information of various acoustic phenomena and is referred to on several occasions in the first
chapter. To dive into this chapter and start optimizing your setup, it is essential that you have made proper
connections for your AIR System. Please follow the illustrations in the “setups” section on pages 7 to 13.
Overview
Angle
-30
Distance from listener
Minimum 1 m
Left front
Right front
Centre
+30
Minimum 1 m
0
Same distance as L or R front 1)
Same distance as L or R front 2)
Same distance as L or R front 2)
Left surround
Right surround
-110 +/-10
-110 +/-10
In general: Symmetry
Basically it is preferred to establish a loudspeaker layout that provides an adequate and equal left/right image. The
basis for this symmetry, meaning that the distance to the left and the right monitors is identical, and if not monitoring
in the near field, then having identical distance to the (identical) side-walls.
The AIR System offer tools for compensation, but symmetry should be established whenever possible.
Not good !
Good !
Front monitors, left & right
For a proper stereo monitoring the monitors should be placed at an angle of ±30º in front of the listening position. This
goes both for a basic stereo setup and for the L&R front monitors in a 4 or 5 channel setup.
ITU 775
Center front monitor
The center front loudspeaker can be placed either:
A: in the middle and in the same distance from
the listening position as the left and right front
monitors or
B: in the middle and on a straight line between
the left and right front monitors.
Surround monitors, left and right
The surround monitors should be placed at an angle
of ±110 (+/-10) and in the same distance from the
listening position as the Left & Right front monitors.
Read more on the following pages.
1)
If you want to fulfill the requirements of the standard ITU 775, you should either use the A-solution or the
B-solution along with a Delay on the center monitor in order to achieve the same time of arrival from all monitors.
Delay-time for each monitor can be adjusted using the AIR PC-IP Installers software.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
PLACING THE MONITORS
Placement of monitors and acoustics do influence monitor sound. AIR series provides powerful tools to compensate for
different placement. Below, please find a description of the most common monitor placements and appropriate
compensation. Using material from the calibration CD together with the AIR placement compensation settings could help
the interaction between the AIR monitor and acoustics the studio. In general we recommended consulting an acoustics
expert for measurement and advanced adjustment and alignment. AIR PC-IP is a PC software package for advanced
installers which, among other things, provides comprehensive EQ and Delay possibilities for each AIR monitor. For
installations where flush mounting is considered, make sure to consult an expert.
Compensation tools within in the AIR System using the
position options in the Calibration menu.
Free standing / "Neutral"
The monitor is placed on a stand or hung down from the
Free Standing
ceiling some distance away from walls and other surfaces.
This position requires the "Neutral" setting (which is default
in the "Calibrate monitor" menu). Try to place the monitor
optimally with regard to reflections and standing waves.
This should be your reference - you can always try to
compare performance of an optimally placed freestanding
AIR monitor ("Neutral" in calibration menu) with any other
monitors placed in other positions (Wall, Corner, Console)
to determine if compensation in these positions is needed.
Wall
Close to wall / "Wall"
When the monitor is placed close to a wall, there is a need
to decrease the bass response. The "Wall" setting found in
the "Calibrate monitor" menu takes this and other things
into account. Try to compare this setting with "Neutral" to
determine which works better in your studio.
If the opposite wall is parallel to the wall where the monitor
is placed, be aware that low frequency cancellation might
occur. Also, look out for standing waves which might occur
Corner
due to an uneven distribution of low frequencies.
Corner
Same considerations as in the "Wall" position, but in a
corner position there is even more need for decreasing
bass response which will be boosted acoustically.
Try the "Corner" setting found in the Calibrate monitor
menu and then evaluate performance comparing with a
frees standing monitor in "Neutral" position. Use the Bass
and Treble filters for fine adjustment.
On the bridge / "Console"
Placing a monitor on a meter bridge of a console result in a
strong single reflection from the surface on the desk which
may color the sound (comb filtering - sounds like the sound
is modulated). In general it helps to minimize the distance /
height between the monitor and the reflective surface.
Although it is not possible to eliminate comb filtering totally
using EQ, try to select the "Console" setting in the
Calibrate monitor menu and evaluate performance in your
studio.
Console
Other situations
In the Calibrate monitor menu, you will also find different
settings which takes combinations of the above into
account - e.g. Console Wall, which should be used if the
monitor is placed both close to a wall and has a console
reflection.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
CHECKING - THE PLACEMENT OF THE MONITORS
Checking the placement
When checking the placement of the monitors you first of
all have to focus on the low frequencies. So the signals to
be used are the low frequency sweeps as you find on the
CD from track 31 to 39.
Overview
1
In the Setup menu: Select setup type (e.g. 5.1 or
stereo) matching your application
Check the phase (using the CD)
Check the monitor positions (using the CD)
Equalize the monitor (using the Bass and Treble
parameters)
2
3
4
Low -frequency sweeps
The tracks 31 to 39 contains the following sweep
sequences
5
Go to: Calibrate monitor
Select correction
Track 31: 200 Hz – 20 Hz
Track 32: 160 Hz – 20 Hz
Track 33: 125 Hz – 20 Hz
Track 34: 100 Hz – 20 Hz
Track 35: 80 Hz – 20 Hz
Track 36: 63 Hz – 20 Hz
Track 37: 50 Hz – 20 Hz
Track 38: 40 Hz – 20 Hz
In the main display select Recall preset now you can
choose from a number of possibilities depending on the
way the monitors are positioned in the room:
Room positions can be selected via the menu:
Setup - Calibrate - Position
• Neutral
• Wall
• Corner
• Console
• Console Wall
• Console Corner
During the sweeps you will hear short “bleebs” telling when
the signal passes one of the ISO center frequencies. (See
tables in appendix)
There are two “bleebs” every time the frequency passes a
whole octave center frequency and one “bleeb” every time
the in-between 1/3-octave center frequencies are passed.
Play all the tracks using only one monitor at a time.
• Select the one that matches your case.
• Select Volume in the main menu to leave preset menu.
• Set the volume: -10 dB
• Test signals on CD. With the AIR monitors you received
a CD containing a lot of useful test signals to be used for
setting up of the monitors.
Evaluation
In the listening position you should hear the signal smooth
and even throughout all frequency sweeps (bearing in mind
that the frequency response of the ear is not flat).
Phase checking
First procedure to be carried out is phase checking.
A number of signals both for two-channel stereo and for
multi channel reproduction are provided with the CD.
If you have a sound level meter this should be set to “LIN”
with no frequency weighting. If the meter does not have a
LIN position you can use the C-weighting, though the
response is attenuated approximately 3 dB at 31.5 Hz and
approximately 6 dB at 20 Hz.
Two channel stereo:
Use track 45-49. L/R signals are presented in phase and
subsequently out of phase.
Multichannel:
Use the tracks 45-64 which contains DTS encoded signals
pairwise comparable: L/R, L/C, L/LS, R/RS. If you do not
have a DTS-decoder you may do the routing of the stereo
L/R signals to other channels in your mixing console.
In the background reading (page 43) you can find
instructions on how alternatively to use a studio
microphone if you do not have a sound level meter.
If OK; continue to next chapter: Calibrating the monitor setup.
If not OK you must find new positions for the monitors.
Checking by ear when listening to the signals:
In phase:
You will hear more bass and the sound coming from a fixed
point between the monitors.
You have to define at what frequency the response
becomes bad. It is a frequency just above this you should
select as the cross-over frequency between the main
monitors and a subwoofer. If not possible to find any good
positions for the main monitors or for the subwoofer you
should consider changing the acoustics of the room.
Equalization is a very common tool for the obtaining of a
more smooth frequency response for steady state signals
(like the sweeps). BUT remember: equalizing can never
repair bad acoustics.
Out of phase:
You will hear the sound image loose bass, the sound
image is diffuse, and the directional information is blurred.
If you already have a phase checking
measurement system that can be used as well.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
CHECKING - PLACEMENT OF THE MONITORS
Equalizing
The AIR System menu offers a two-band shelving type
equalizer. This can be used individually on each monitor,
and it is implemented for a fine adjustment of the tonal
balance.
Range:
±6 dB
Adjustment step:
Band I:
Band II:
0.5 dB
100 Hz - 1 kHz
1 kHz - 5 kHz
Shelving
Filter type:
You should be very careful using this tool if you are doing
the adjustment by ear. In a room with good acoustics
equalizing should not be necessary at all.
As a test signal you can use full bandwidth pink noise
(tracks 2 or 13) on the test-CD
In a room that you feel heavily over damped at higher
frequencies you may wish to ad some level in the high end
in order to get the right balance. Do it with care then.
In a highly reflective room you may wish to attenuate the
high frequencies.
If you have made a good job placing the monitor in a
proper position you should not touch the low frequency
band.
Notice: If you have done any adjustments using the
equalizer, you should leave the room and come back 15
minutes later bringing some music, that you know well.
Play this music. Now your first impression is very important
for the assessment of the tonal balance of the monitor
system. Listening during a long time will make the hearing
perform a change in the perceived timbre. This is what we
can compare to the "white balance" of the eye. After a
short time you are getting used to a new tonal balance or
timbre. What sounds "cool" or "fat" then is not necessarily
sounding right for monitoring purposes.
Additional Equalizing can be done via the AIR PC-IP
Installers Software.
AIR PC-IP - Advanced Installers PC - Interface Packages
The Installers software includes a 4 band Parametric EQ,
for more precise EQ adjustment of each monitor.
Next
Go to: Calibrating the main monitor setup.
Read more in the Background Information chapter.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
CALIBRATING - MAIN MONITORS
Overview
X-CURVES
For small rooms, defined as less than 5300 cubic feet or
150 cubic meters, ANSI/SMPTE 222M calls for a
modification of the X-curve with flat natural response to 2
kHz and then a 1.5dB per octave roll off above 2 kHz.
This curve is useful when mixing in a small room and be
playing back in a large room.
1
Select Setup menu from the Main menu
- then Calibrate monitor
2
Select each monitor and set calibration level
using the CD
Another variation on the curve is to begin the high end roll
off at 4 kHz and roll off 3dB per octave instead of 1.5 per
octave.
Calibration procedure
The calibration has to be made to ensure that all monitors
produce the same sound pressure level in the listening
position when fed with the same signal.
The level of the input signal can be locked to a specific
sound pressure produced by the monitors.
X-Curve 1
Interchannel calibration
In the main menu:
• Select Setup menu
• Then select Calibrate monitor
• Select monitor Master L front
Now you can read the settings of this monitor.
• Set the Calib to 0.0 dB
• Start the CD and play track 11/23 (two channel stereo)
or track 11 (multi channel DTS)
The tracks contain 500 Hz – 2 kHz filtered Pink Noise.
Now: the sound pressure level is “measured” or registered
by ear.
Continue to the next channel. Using the Calib adjust to set
the same level as the first monitor. If using a multi channel
set up continue to the next monitors.
Acoustic level calibration
In some parts of the audio industry the monitoring system
has to be related to absolute acoustic levels.
On the CD, the tracks mentioned above are recorded at
–20 dBFS. This level correspond to different acoustic levels
depending on the kind of business you are in:
X-Curve 2
Film
Video
Music
83 dB(C)
78 dB(C)
78-93 dB(C)
• Select the first monitor (L).
• Play the track on the CD related to this monitor.
• Set Calib to 0.0 dB.
• Adjust the global volume until the desired C-weighted
level is obtained on a sound level meter in the listening
position.
• Go on to the next monitor
• Adjust Calib till the same C-weighted level is obtained
from this monitor.
• Continue the procedure until all monitors are calibrated.
• Exit calibration.
Read more on pages 38-39.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
PLACING THE SUBWOOFER
Overview
Placement on the floor
Advantages
Disadvantages
In the corner
Gain of bass response
Excitation of most standing waves in the
room, hence very uneven sound distribution
Adjacent to wall
Free standing
Gain of bass response
Excitation of several standing waves in the
room, hence very uneven sound distribution
Position can be optimized with
regard to standing waves
It may take up space on the floor
Floor standing
The subwoofer is under normal conditions always placed directly on the floor. This is taken into account in the basic design
and the basic settings of the AIR system.
Placement in the corner
This is a π/2 radiation, which yields a gain of 18 dB in the frequency range
where the monitor is considered to be omni-directional.
Most standing waves have their maximum in the corners of the room.
Especially if the room has a cubic or shoebox shape (the room having all
walls in parallel). the placement of the subwoofer in the corner may cause
uneven sound distribution of the bass.
The corner position is normally only preferred if all opposite surfaces in the
room are not in parallel.
Adjacent to a wall
This is a π radiation, which yield a gain of 12 dB in the frequency range
where the monitor is considered to be omni-directional.
This position adjacent to a wall is commonly used, and it can be OK, but it
must be noticed that the subwoofer should neither be placed in the middle or
in the quarter points between two sidewalls if these are in parallel.
(See pages 29-32 for the optimum positions with regard to standing waves.)
Free standing
This is a π radiation, which yield a gain of 6 dB in the frequency range where
the monitor is considered to be omni-directional.
The free standing position is highly recommended in all cubic and shoebox
shaped rooms.
In any case: Try to avoid placing the woofer on the half or quarter lines
between walls.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
CHECKING - SUBWOOFER PLACEMENT
Do not place the subwoofer on these lines quarter or
halfway between walls.
Evaluation
Overview
In the listening position you should hear the signal smooth
and even throughout all frequency sweeps (bearing in mind
that the frequency response of the ear is not flat).
1
2
3
4
Set the volume at -20 dB in the main menu
Set Bass Management to 120 Hz
Set Bass Management to “on”
Check the monitor position using the CD,
tracks 30-44
If you have a sound level meter this should be set to "LIN"
with no frequency weighting. If the meter does not have a
LIN position, you can use the C-weighting, though the
response is attenuated approximately 3 dB at 31.5 Hz and
approximately 6 dB at 20 Hz.
5
Go to: Calibrating the subwoofer with the main
system.
Test signals on CD
With the monitors you received a CD containing a lot of
test signals. These test signals are very handy when
setting up the monitors.
If you do not have a sound level meter you can use a
studio microphone instead. This is described later in this
chapter.
Low frequency sweeps
Tracks 30 to 37 contains the following sweep sequences.
If you hear the signal smooth and even throughout the
frequency sweep you can continue to the next chapter:
Calibrating the subwoofer with the main monitors.
Track 31:
Track 32:
Track 33:
Track 34:
Track 35:
Track 36:
Track 37:
Track 38:
Track 39:
200 Hz - 20 Hz
160 Hz - 20 Hz
125 Hz - 20 Hz
100 Hz - 20 Hz
80 Hz - 20 Hz
63 Hz - 20 Hz
50 Hz - 20 Hz
40 Hz - 20 Hz
32 Hz - 20 Hz
If not OK you must find new positions for the subwoofer.
Next
Go to: Calibrating the subwoofer with the main monitors.
During the sweeps you will hear short "bleebs" telling when
the signal passes one of the ISO center frequencies. There
are two “bleeps” every time the frequency passes a whole
octave center frequency and one “bleeb” every time the in-
between 1/3-octave center frequencies are passed.
Play all the tracks using only the subwoofer.
Mute all other monitors.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
CALIBRATING THE SUBWOOFER - with the main monitors
Bass Management
To Calibrate
Bass management (sometimes called bass redirection), is
a very important and useful tool - and it is in general an
absolute necessity if you want to make a 5-channel setup
in a small room! There are several reasons for this.
1
2
3
4
5
6
7
Main menu, set volume -30 dB
Main menu, select Bass Management: 80 Hz
Main menu, select Setup menu: Calibrate level
Select a task for the monitor
Run CD low frequency sweeps; tracks 40-42
If needed: Adjust level or crossover frequency
Store and Exit / get ready for music!
The bass management system is designed to subtract the
bass contents of all main channels and reproduce this by
the use of a subwoofer. The AIR-series provides a number
of possible cross-over frequencies that can be determined
by the user.
Bass management on
The volume is set to a reasonable level (first item in main
menu) ex -30 dB.
In the main menu Bass Management is selected. If no
other preferences for a crossover frequency 80 Hz is
selected.
If measurements or listening to the main monitors have
indicated uneven level distribution or uneven frequency
response at frequencies above 80 Hz, a higher crossover
frequency should be selected.
Checking summing phase cancellation
In a basic 2-channel setup or 5-channel setup (like the ITU-
775) a sub-woofer is not specified and is not required. But
making audio production to be played back on consumer
equipment, one has to ensure that the mix will sound right
in this situation. Many consumer setups containing a
subwoofer. Hence it is very important to check what the
summing of the bass is like. If the program material
basically is out of phase, the bass will be cancelled when
summed electrically. But this is not the case if the bass
signals are reproduced by the main monitors and summed
acoustically. A dramatic difference may exist!
Checking the Crosspoint
In order to confirm the selected crossover frequency, the
CD is used. To be sure to listen to one monitor channel at
a time one of the main channels are selected in the Setup
menu/Calibrate monitor menu. For a start Master Left can
be selected.
Playback the CD track containing the low frequency
sweeps (trax 31 to 42). Listen to the response or perform
sound level measurement if you have a meter connected.
Controlling standing waves
It can be very difficult to get two monitors in the right
position in order to prevent the excitation of the standing
waves. But placing five monitors are even more difficult!
Each monitor should play under the same conditions as the
others but that is seldom the case.
If you have a spectrum analyzer you can instead play the
CD-tracks containing full bandwidth pink noise.
Any uneven frequency response across the crossover
frequency should be avoided.
You may go back to the setting of the crossover frequency
in the bass management setup and select another
frequency if appropriate.
After doing the adjustment on one channel, the other
channels should be monitored one by on and finally all
channels at one time.
Three front monitors can normally be placed away from
disturbing boundaries to prohibit the excitation of the
standing waves. But in small rooms the rear monitors very
often are placed in a corner or on a wall. Having the full
frequency range reproduced in a monitor like that, there
may occur serious problems which results in a poor low
frequency sound distribution in the room.
So this is another reason for using bass management.
Simply: Only one monitor - the subwoofer - has to be
placed in a safe position. The cross over frequency can be
selected to a value just above the problematic frequency
range.
Now your system is calibrated.
Read more in the section: Phase Adjustment on the
following page.
Three other parameters to consider in relation to the
subwoofer:
LFE Low Pass Filter
Switches On or Off a very steep (7th order) low pass filter
at 120 Hz. When switched On, the LFE signal is filtered for
content above 120 Hz. Switch this filter On when a media
encoder is not in use and switch it Off when your signal
have been through a media encoder / decoder (Most media
encoders - DTS, Dolby etc. - employees an anti-aliasing
low-pass filter. Therefore in a production environment it is
important use this filter when monitoring the LFE channel in
order to access how the signal will sound after encoding /
decoding (in a domestic or cinema environment).
28
Download from Www.Somanuals.com. All Manuals Search And Download.
CALIBRATING THE SUBWOOFER - with the main monitors
LFE Gain
Iteration
Range: 0 to +14dB
The LFE channel can be boosted up to 18dB using this
parameter.
You may need to iterate quite a bit, maybe readjust the
level calibration a bit too. You may even want to reconsider
your initial choice of X-over frequency and/or monitor
placement and start the process over again. Be patient:
The time spent getting this right is well spent.
Polarity
Range: 0 or 180º
If the Subwoofer is correctly placed, setting the Polarity
parameter at 180º should result in a full Phase cancellation
at the set Cross -over frequency. If this is not the case - the
Phase parameter described below should be adjusted.
Phase
Range: 0 to 180º
Phase Introduction
The integration of the AIR-Base subwoofer with the AIR
monitors requires on-location tuning. Apart from level
calibration and choosing a Bass Management Crossover
(X-over) frequency, the issue of phase alignment remains.
For this purpose, the AIR-Base has a 0-180 degree phase
adjustment (in 5 degree steps) and a Phase Reverse
function. The optimum setting of these will depend on
several factors:
1. Room acoustics
2. Placement of monitors and listening position
3. Choice of X-over frequency
4. AIR Monitor type (6 or 15)
Phase settings are automatically saved and linked
to the currently selected Cross-over frequency.
Phase settings are Global settings and are
therefore not saved with individual presets.
Initial setting
During calibration of the AIR-Base's DSP software, we
have come up with default settings that we found optimal in
our listening room. If you're placing the AIR-Base at the
same distance from the listening position as your AIR
Monitors, the default phase settings can be used as initial
guidelines for setting the phase. If the distances are
significantly different, these values are not likely to be
optimal.
Phase Adjustment
Now play repeatedly a low-frequency sweep signal that
sweeps over the X-over frequency that you have chosen.
Tracks 31-42 on the AIR Test CD may be used. Between
each sweep, change the Phase Reverse setting. Note the
difference. Ideally, with the right level calibration and phase
setting, the sound should cancel out and virtually disappear
at or near the X-over frequency, when the Phase Reverse
control is in one position. Tune Phase Adjust to get the
largest possible difference between the two Phase Reverse
settings. Then leave it in the position where no cancellation
occurs.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
Acoustics
When we talk about making a room "sound right", we are
probably dealing with room acoustics as a science
acoustics has been around for about hundred years.
Until then good acoustics happened by experiment, by
experience, or simply by accident.
Today we know a lot about the parameters that influence
the "sound" of a room.
Talking about the control room we know that basically this
room should act as neutral as possible. But this is not
always the case. Lets just take a short look on some of the
issues, than one must be aware of.
• One sound source, one receiver and no room
• Only the direct sound is received.
Good acoustics
Here is a list of important parameters concerning good
acoustics.
• Proper reverberation time
• Good sound distribution
• Adequate sound pressure level
• Low background noise level
• No echo (flutter echo)
Now lets have a look on these headlines that will be
adequate for the most purposes concerning sound
production.
• One sound source, one receiver, and one reflecting
surface.
• The sound is received twice. (In the control room this is
normally experienced as comb filtering, see later).
Reverberation time
The reverberation time is defined by the time it takes a
sound to attenuate 60 dB after the source is stopped.
In the real life we can experience reverb times from
approximately 0 sec. (outdoors or in anechoic chambers) to
something like 10-12 sec. In special reverb chambers the
time may exceed 20 sec.
Control rooms normally should have a reverb time around
0.2 - 0.3 sec.
Why do we have reverberation? The speed of the
propagating sound wave is very slow - at least compared to
light: approx. 1130 ft. or 340 m per sec.
If there are no reflecting surfaces between the sound
source and our ears, only the direct sound is heard and
there is no reverberation.
• One sound source and one receiver in a room.
• The sound impulse is reflected in many surfaces.
All the reflections are melting together and heard as
reverberation.
If there is a single reflecting surface we may hear the
reflected sound in one way or another, but there is still no
reverberation.
If the sound is generated in a room, there are a whole lot of
reflections. Each of these travels different paths with
different distances on the way to the receiver. Each time
the sound hits a surface it may loose some energy if the
surface is absorbing.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
One square meter (1 m2) Sabine is comparable to
Sabines formula
an open window with an area of one square meter:
The sound that hits the window will disappear and
never return. One square meter Sabine is one
square meter with full absorption.
Sabine is the father of modern acoustics. He found that
reverberation time is described by a relationship between
the room size and the amount of absorption in the room.
Larger rooms - longer reverberation. More absorption -
shorter reverberation.
The basic formula sounds simple, but the problem is that
the materials in the room will absorb differently at different
frequencies. The absorption may range from nothing (fully
reflective) to total absorption.
T = 0.161 * V / A
where
T:
V:
A:
0.161:
Reverberation time in seconds
Volume in m3
Absorption in m2 Sabine
Is a constant (to make the calculation
right with the actual units)
A proper reverb time should be constant with frequency,
but this is not always the case because of the behavior of
the materials in the room. The low frequencies are the
most difficult to control.
This is why the reverberation time against frequency in
practice may look like this:
X-studio, re v e rbe ration time in control room
0,80
0,70
0,60
0,50
0,40
0,30
0,20
0,10
0,00
63
125
250
500
1000
2000
4000
8000
Frequency [Hz]
Reverberation time measured in a control room. From 250 Hz and above the curve is nicely placed
around .3 sec. But belov the reverb time rises to .75 sec. which is too much.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
Absorbers
All materials in the room act acoustically even if they are
not so-called acoustical materials. Basically we have three
kinds of absorbers.
Diffusers
A diffuser provides diffuse reflection of the sound
radiated against it. It can be a very useful solution
in cases where reflections are disturbing the sound
image and it is not advisory to ad further
Membrane absorbers
absorption. So in order to reduce flutter echoes,
comb filtering etc., special elements can be placed
on the "disturbing" surface. These elements must
have dimensions comparable to the frequencies at
which diffusion is wanted.
This kind of absorber includes wooden floors, windows,
doors, etc. This absorber provides absorption in the low
end of the frequency range. The efficiency is normally not
very high, but under normal conditions large areas are
included in the basic room construction. Special designed
membrane absorbers can be very effective.
Absorbtion or diffusion ?
Resonance absorbers
Resonance absorbers include slit panels, perforated plate,
Helmholtz resonators etc. These absorbers are normally
used in the frequency midrange. The absorption is medium
to high.
A special technique developed by Manfred
Schroeder is very capable in making a smooth and
controlled diffusion. These diffusers normally
referred to as "Schroeder Diffusers" can be found
as prefab modules.
Porous absorbers
These absorbers include mineral wool, carpets, curtains,
and so on. They can be very effective, but the thickness of
the material has to be taken into account. Thin layers will
only absorb the highest frequencies. (Think of a rehearsal
room in the concrete basement where the only damping is
a carpet on the floor: Not good at low frequencies!)
To absorb a given frequency (and all frequencies above)
the thickness of the absorber must be the quarter of the
wavelength of that frequency. Or: the front of the material
must be placed at a distance of one quarter of the
wavelength.
20,0
10,0
0,0
Cross section of one example of the
Schroeder Panel.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
BACKGROUND INFO - ACOUSTICS
90º the sound will be reflected right back where it came
Standing Waves
from. Under certain circumstances the sound wave will
meet itself again. For instance if the sound is reflected
between to parallel walls. This becomes a problem, when
the sound wave not only meets itself, but when it meets
itself in phase. And this will happen when the distance
between the walls is half a wavelength of the radiated
sound wave. Or one whole wavelength - or 1½, 2, 2½ and
so on.
Standing waves exist in all kind of rooms. The shape of the
room, the dimensions of the room, and the relationship
between the dimensions of the room, are important
parameters that will determine the frequencies around
which the phenomenon exists as well as the distribution of
these standing waves. But how do they occur?
Imagine a sound source. When the sound is emitted the
sound wave will propagate in all directions if no obstacles
in sight. This will of course happen with the speed of
sound. Now, if the sound source is placed inside a room
the sound wave will hit the boundaries of the room. If the
boundaries consist of acoustically hard (reflective)
This phenomenon is called standing waves. Actually the
sound wave is not standing. But it is experienced like that
because the sound pressure maxima and minima are
positioned in fixed places in the room.
surfaces, the sound is reflected. If the angle of incidence is
The sound field is
initially radiated
having a radial wave
front but within a few
reflections the sound
field has obtained a
plane wave front.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
Room modes
These special frequencies are also called room modes. Standing waves between parallel walls are called axial modes.
Other modes exist. For instance tangential and radial modes. (See the illustration). Normally the axial modes are the
strongest.
Axial
Tangential
Radial
34
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
The standing waves are characterized by having a maximum sound pressure at the boundaries of the room. Depending
on the frequency there are one or more dips across the room.
In a box shaped room the frequencies can be calculated as follows:
c
nl
l
n
w
nh
h
f =
(
)+ ( b )+ (
)
2
where
f =
frequency in Hz
c =
l =
speed of sound (approx. 340 m/s or 1130 ft/s)
length of the room
w =
width of the room
h =
height of the room
n =
integer from 0 and up
How does the standing waves influence the sound
field?
How to prohibit standing waves
Parallel walls in the room should be prevented. Then the
strongest modes are suppressed.
The maxima of the standing waves are shown in the figure.
The curve expresses the area of the room where the actual
frequency is audible. At the minima the frequency is
represented at a much lower level (sometimes -40 dB
compared to the maximum).
When placing the monitors it is important that as few
modes as possible are excited. This is why the monitors
should not be placed in a maximum of a standing wave.
If the room has the same dimensions as length, width, and
even height it is very problematic to obtain an even sound
distribution.
When monitors are built into walls you should therefore be
concerned that the opposite wall is not parallel to the
monitor wall.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
At low frequencies a monitor can be considered
as to radiate the sound energy in all directions.
This is also called a 4 π radiation.
When placing the monitor close to a solid
boundary - for instance a wall - the sound
energy that should have been radiated in the
direction of the wall instead is radiated into the
free half space. Hence the sound pressure is
doubled in the half space, which yields +6 dB.
This is also called a 2 π radiation.
Placing the monitor against two boundaries - for
instance in a corner limited by two walls - it is
now radiating to the quarter space. Now the
sound pressure is doubled twice, which yields
+12 dB.
This is also called a π radiation.
Placing the monitor against three boundaries -
for instance in a corner limited by the floor and
two walls - the sound is radiated into 1/8 of the
space. Compared to free space, the sound
pressure now is increased by 18 dB.
This is also called π/2 radiation.
In practice the placement close to boundaries will influence the frequency
range below 125-150 Hz.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
Comb Filtering
The filtering function that arises when a signal is added to itself after having been delayed in time is called a comb filter.
The resulting frequency response resembles a comb, hence the name.
Two 500 Hz sinusoidal tones added. The second tone is delayed 1 ms hence the sum is zero
Two 1 kHz sinusoidal tones added. The second tone is delayed 1 ms hence the sum is the
double (+6 dB).
The comb filter function is almost never intentional, but it is heard all the time in sound productions, where it can arise both
acoustically and electrically.
Acoustically, it typically occurs when the sound on its way from source to recipient takes in part a direct path and in part an
indirect path via a single reflective surface. The reflection must be attenuated at least 10 dB and preferably 15 dB in order
for it not to have an effect on the sound field at the recipient position. Electrically, the phenomenon arises when two
microphones with a certain distance between them capture the same signal and the level from each microphone is of the
same order of magnitude.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
or +
Two typical situations in which comb filters arise, either acoustically or electrically.
In general: All digital signal processing takes time. This means in practice that comb filter effects can arise if you loop a
signal via, for example, a compressor and combine this signal with the original.
An example of a comb filter created by the combining of two signals with the same amplitude, but
with a time delay between them of just 1 ms.
It can be seen that a dip occurs due to cancellation at 500 Hz, 1.5 kHz, 2.5 kHz, etc.
It can also be seen that the two signals add to double their value (+6 dB) at low frequencies and
with a full wavelength's delay at 1 kHz, 2 kHz, 3 kHz etc.
Dip frequencies
Cancellation occurs for a comb filter at all the frequencies where the two signals are in opposite phase. This occurs when
the time delay comprises duration of ½, 1½, 2½, etc. periods. At 1 kHz the period is 1 ms. Half of the period is 0.5 ms.
If a time delay of precisely 0.5 ms occurs, it means that cancellation will arise, not just at 1 kHz, but also at 2 kHz, 3 kHz,
4 kHz etc.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
ACOUSTICS - BACKGROUND INFO
Rear wall cancellation
When the monitor is set up at some distance in front of a wall, reflections from the wall may occur and influence the
perceived frequency response. This could result in comb filtering if all frequencies produced by the monitor were radiated
in all directions. But the monitors are typically only omni-directional at low frequencies.
The result of the reflection is a single or few dips in the frequency response perceived in front of the monitor.
This frequency is
cancelled because of the
oppositely phased
reflection
The frequency response may look like this: one cancellation at the frequency that has a wave length of four times the
distance to the rear wall.
The dip - or cancellation frequency - is dependent on the
distance to the wall. If the distance is 1 m, the first dip
frequency will occur at a frequency with a wavelength of
4 m.
A closer position will result in a cancellation at a higher
frequency. This is then limited by the frequency where the
monitor becomes directional and does rot radiate sound to
the rear.
l = c / f
where
A farther position will result in cancellation at a lower
frequency. This is limited by the distance being so long,
that the reflected sound is attenuated due to the long extra
path travel.
l = wavelength [m] (or ft.)
c = speed of sound [m/sec] (or ft./sec.)
f = frequency [Hz]
Hence
4 = 344 / f
f = 86 Hz
39
Download from Www.Somanuals.com. All Manuals Search And Download.
THE SUBWOOFER - BACKGROUND INFO
The Subwoofer
A subwoofer is a monitor that reproduces low frequencies. The purpose is to take over from the main monitor(s) as
frequencies approach the lower end of the frequency range. I.e. approximately below 120 Hz. When used in professional
monitor systems it is commonly preferred to use subwoofers below approximately 80 Hz. But of course it depends on the
performance of the main monitors.
The low frequency contents of just one or all the main channels can be directed to one subwoofer.
From the psycho-acoustics we know that there is no directional information in audio signals below approximately 120 Hz.
Hence the advantage of placing the subwoofer in a position where the best distribution is achieved.
However it is very important that the distortion in the subwoofer is reduced to an absolute minimum because distortion
results in the production of harmonics (2, 3, 4 etc. times the frequency reproduced). Especially the third harmonic may
dominate. Reproducing a frequency of 100 Hz can result in the generation of an audible frequency component at 300 Hz,
which presents directional information to the human hearing system.
Bass management
Bass management (sometimes called bass redirection) is a very important feature - and it is in general an absolute
necessity if you want to make a 5-channel setup in a small room! There are several reasons for this.
The bass management system is designed to subtract the bass contents of all main channels and reproduce this by the
use of a subwoofer. The AIR-series provides a number of possible cross-over frequencies that can be determined by the
user.
L
C
R
Ls
Rs
Σ
Sub
Principal setup for the bass management. It can be used
with any number of main monitors up to five.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
THE SUBWOOFER & LFE CHANNEL - BACKGROUND INFO
Checking summing phase cancellation
disturbing boundaries to prohibit the excitation of the
standing waves. But in small rooms the rear monitors very
often are placed in a corner or on a wall. Having the full
frequency range reproduced in a monitor like that, there
may occur serious problems which results in a poor low
frequency sound distribution in the room.
In a basic 2-channel setup or 5-channel setup (like the ITU-
775) a subwoofer is not specified and is not required. But
making audio production to be played back on consumer
equipment, one has to ensure that the mix will sound right
in this situation. Many consumer setups provide a
subwoofer. Hence it is very important to check what the
summing of the bass is like. If the program material
basically is out of phase, the bass will be cancelled when
summed electrically. But this is not the case if the bass
signals are reproduced by the main monitors and summed
acoustically. A dramatic difference may exist!
So this is another reason for using bass management.
Simply: Only one monitor - the subwoofer - has to be
placed in a safe position. The cross-over frequency can be
selected to a value just above the problematic frequency
range.
Controlling standing waves
It can be very difficult to get two monitors in the right
position in order to prevent the excitation of the standing
waves. But placing five monitors are even more difficult!
Each monitor should play under the same conditions as the
others but that is seldom the case.
Three front monitors can normally be placed away from
The LFE Channel
LFE is short for Low Frequency Enhancement or Low Frequency Effects, the first being the original name but the second
being the most correct with regard to its application.
It is also referred to as the .1-channel, which indicates that the frequency range of this channel is only a fraction of the
other channels in a multi channel setup. The actual frequency range is 20 Hz to 120 Hz.
When reproduced the signal is gained by 10 dB compared to the main channels. This provides a possibility of reproducing
occasional high-level low frequency contents without affecting the general level setting of the main channels.
Leading signals to the LFE channel should be evaluated carefully in each case as not all transmission or reproduction
systems may include this channel. In the music mix there is no special reason for using this channel unless you are
recording the 1812 Overture with its canons and all that stuff.
Cross-overs
L
C
R
Ls
Rs
Sub
Σ
Low Pass
LFE Gain
120 Hz
+10 dB
41
Download from Www.Somanuals.com. All Manuals Search And Download.
DELAYING MONITORS
LINE-UP & CALIBRATION
ITU 775
Acoustic summation of audio
signals
When using a 5.x setup with monitors arranged on a circle
line (as with ITU 775) the distance from the listener to each
of the main monitors is the same.
The total sound level in the acoustic summation of two
sound sources, for example of two monitor monitors,
depends upon both the signal and the acoustics. The
sound sources can be correlated or uncorrelated.
In case of limited space the three front monitors can be
arranged on a straight line. To compensate the center
monitor being closer to the listener than the left and right
monitor, the center signal can be delayed. To obtain
coincident arrival of the sound from all front monitors the
delay ranges normally between 0 and 3ms. dependent on
the off-set needed.
The listening position (or measurement position) can be
either in the direct sound field or in the diffuse sound field.
In the direct sound field, there is only one sound direction.
This direct field exists either in the open, in a reflection-free
room or close to the monitors. The diffuse sound field
occurs in a room when you are so far away from the
monitors that the portion of direct sound is less than the
sum of all the reflections. The distance from the monitors
where the direct sound field and the diffuse sound field are
equally large is called the critical distance. In a control
room, it can typically be 1-3 meters. The near field in front
of the monitors can be regarded as a direct field.
The speed of sound is approximately 340 m/s or 1130 ft./s.
Approximately 1 ms. of delay will be used per 1 ft. or 30cm,
when the monitor has to be "moved" backwards.
Cinema setup
In the setup for the cinema the front monitors are always
arranged on a straight line. In this case the audience is
placed closer to the surround monitors than the front
monitor. In order to retain the directional information
towards the screen the surround monitors are delayed.
Normally the Haas-effect is taken into account. In the
listening position the sound from the surround monitors will
arrive about 15-20ms after the sound from the front
monitors. The delay times involved with cinema processing
for the surround channel is dependent on the size of the
mixing facility, the cinema, or the home theatre/living room.
Based on all monitors in phase, the sum of the sound
pressure from two monitors each playing at the same level
is 3 dB, unless the signals are correlated (they are
identical) and the sum is measured in the direct field. In
this situation the resulting sound pressure level is 6dB
higher than the level of the individual monitors.
The procedure is to calculate the difference in distance
between front monitors and the closest surround monitor.
Then the time difference is calculated. To this is added 15-
20ms.
Example: From a listening position there are 20 meters to
the front monitors and 5 meters to the surround monitors.
The difference is (20-5) 15 meters.
The time is 15/340 sec, which equals .044 sec or 44ms. To
this is added 15ms. The result is that the surround signal
has to be delayed 59ms (or the closest possible).
Acoustic calibration of multi-channel systems
Calibration of the acoustic sound levels has been a
requirement for many years when working with sound for
film, although it has not been particularly common in other
branches of the sound industry. However, with the
widespread use of multi-channel formats for all forms of
music and film presentation in the home, it has turned out
to be beneficial to also have the acoustic levels under
control here.
It is important to differentiate between production for the
cinema and production for 5.1 channel reproduction in the
home based upon ITU 775.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
LINE-UP & CALIBRATION - BACKGROUND INFO
Calibration of 5.1 in an ITU-775 arrangement
In a 5.1 system based on the ITU arrangement, all main channels have in principle the same conditions: there is one
monitor per channel and each is placed the same distance from the listener. Internationally, there is however neither
agreement on the level nor on the bandwidth for the noise signals that is used for acoustic calibration. Pink noise is good
since it includes all frequencies, however it is impractical due to its "unsettled" character, which makes it difficult to
measure at low frequencies.
Surround Sound Forum
Surround Sound Forum is a German interest group composed of the VDT (sound technicians), the IRT and the SRT. The
SSF has prepared guidelines, which are generally accepted in Europe. Three test signals are specified in it, which are
recorded at -18 dBFS (RMS).
Measurement Signals
Listening Level
Signal
(only in one channel)
PPM level
t <0,1 ms
PPM level
t <10 ms
RMS level
Sound pressure
Sound pressure
level
level
SLOW
[dB]
SLOW
[dB(A)]
[dB]
-18
-9
[dB]
-18
-13
-15
[dB]
-18
-18
-20
1 kHz sine
Pink noise 20 Hz-20 kHz
Pink noise 200 Hz-20 kHz
82
80
78
78
-11
SMPTE
does not influence the sound field. The microphone should
have a flat frequency response.
The corresponding standard from SMPTE (RP155) uses a
standard of -20 dBFS for the reference level. Here, the C-
weighted sound pressure level of a 500 to 2 kHz noise
signal ends up at 83 dB.
Place the microphone on a stand positioned at the listening
seat. Leave the microphone pointing upwards in order to
avoid sound pressure build-up in front of the diaphragm
and to provide equal conditions to monitors in all directions.
Calibration of cinema systems
In a cinema, the listeners are sitting far from the monitors.
Presumably, the majority sits in the diffuse sound field. In
any event, attempts are made to establish a diffuse sound
field from the surround monitors. Hence when the sound
pressure is measured inside the cinema or in a mixing
theatre it must be averaged over many different
measurement locations. The typical basis for the majority of
the standards is at least four locations. If there are different
areas for the audience, for example main floor and balcony,
measurement should be made in at least four locations in
each. Before this measurement can be performed, the
system's frequency response must also be in order.
Connect the microphone to a mixing desk or a recording
machine that has a meter built in.
Play back a track containing pink noise on the CD you got
with the monitors. (or use one of the other tracks as
instructed to during setup and calibration.
Adjust the gain in the microphone channel until the meter
deflection reaches a point 10 dB below full scale. This is
now your reference for your measurements. Be sure that
you have marks on the scale that makes it possible to read
steps of 1 or 2 dB on either side of the reference
deflection. If 10 dB below full scale is not an adequate
point on your meter you may choose another one, just be
sure to have a reading on a adequate resolution.
How to measure the sound
pressure?
Sound level meter or microphone
If you use this microphone setup as described, it can be
used for the level comparison between the individual
monitors.
If you are used to perform acoustic measurements you
probably already own a sound level meter. This can be
used for the level calibration of the monitors.
Absolute sound pressure levels can be measured if you:
a) are using a well calibrated microphone channel
b) know the sensitivity of the microphone.
If you do not have a sound level meter, there still is another
possibility:
Take an omni-directional microphone. (This is also called a
pressure microphone). A studio condenser microphone is
normally preferred but the microphone must not be too big.
Then a simple clip microphone can be used instead as it
43
Download from Www.Somanuals.com. All Manuals Search And Download.
THE AIR REMOTE
Introduction
When perfect setup and calibrations is in place, optimal performance from the AIR system monitors is achieved by
controlling level on the monitors themselves as opposed to controlling via the mixing console. Therefore a remote control is
a natural extension to the AIR monitor system.
Remote Control Features
• Instant access of three different user defined Reference Level settings.
• Instant Preset Recall function of up to 4 presets. This way you can
easily switch between different setups from your listening position.
• Mute/unmute and solo function for each monitor in the setup.
• Easy Master Level adjustment via large potentiometer.
Ref. Level selection
Preset Selection
Shift key for preset
selection 1/3 to 2/4.
Master Volume
Mute/Unmute/Solo for
each channel
44
Download from Www.Somanuals.com. All Manuals Search And Download.
THE AIR REMOTE
REF LEVEL 1-3 keys
VOLUME potentiometer
To recall Reference Level 1-3:
Press relevant key shortly. The key LED indicates activated
Reference Level.
If no REFERENCE LEVEL keys are activated this control
sets the Master volume on all channels in the system.
If one of the REFERENCE LEVEL keys are activated,
these will define the reference level.
To set Reference Level 1-3:
When REFERENCE LEVEL keys are deactivated Master
volume returns to the level defined by the position of the
VOLUME potentiometer.
Set level using the large VOLUME dialer in the center of
the remote. Press and hold relevant Reference level key
for approx. 2 seconds. The LED will flash 3 times and then
the new Reference level is set.
Power up state: Potentiometer setting defines
volume level.
Power up state: Off (volume defined by potentiometer)
PRESET 1/3 AND 2/4 keys
Potentiometer LED function:
These keys will recall presets 1/3 & 2/4 depending on the
position of the SHIFT key.
Power up state: Off (no presets recalled).
As soon as the volume level is defined by the
potentiometer setting, the LED is on. LED goes off when
volume is set by other devices than the remote unit.
SHIFT key
Power up state: LED on (Potentiometer setting defines
volume level).
Combined with the PRESET 1/3 AND 2/4 keys (described
above) presets 1 to 4 can be recalled.
Preset Bank 1 is presets 1and 2. Preset bank 2 is presets
3 and 4.
Power up state: Preset Bank 1 selected.
MUTE/UNMUTE - SOLO keys for the channels:
L - C - R - Ls - SUB - Rs
The key LEDs indicates the following states:
LED ON
Speaker on
LED OFF
Speaker Mute
LED Flashing Speaker Solo
Mute/Unmute
With a single press on these keys the monitors are
muted/unmuted.
Solo Function
Press and hold one of the keys to activate Solo function for
corresponding channel.
All other monitors can enter solo mode simultaneously.
If a key is pressed (not held) the original mute status will
be recalled.
Power up state: On
45
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR SOFT
The AIR SOFT is a software editor for the AIR System monitors. All parameters controllable via the display locally on the
System Controller, as well as the Reference Level features available via the AIR Remote can be controlled via the AIR Soft
program. As your AIR monitors most likely are placed out of your immediate reach we are therefore convinced that you will
benefit from having full control over your monitor system from your PC or Mac.
Please find additional parameter explanations on pages 18-20 in this manual.
Minimum requirements
Installation procedure PC:
• Place the Installation CD in your CD ROM drive and
open CD contents.
• PC running Windows 98, 2000, or XP.
• Mac computer running OS 9.2 or higher or Mac OS X.
• 64MB RAM
• Press Setup
• 800x600 24bit screen resolution
• 1 free Serial port or USB.
• Follow the instructions.
Installation procedure Mac:
• Enter the Installation CD in your CD ROM drive and
open CD contents.
• Run the installer.
• Follow the instructions.
Connect from Serial or USB port to any free TC
LINK connection on your AIR monitors using
ONLY the cables described on page 52.
Serial to Cat-5 cable is supplied but if an USB
port is used, an USB to Serial COM 9 port
cable must be acquired.
Navigating AIR SOFT
Network
Calibrate - Main Monitors
Main Screen
Press to enter preset list.
Calibrate - AIR-Base
System Setup
46
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR SOFT
Bass Mgt - Bass Management
Indicates the selected Cross-over frequency for Bass
Management.
Main
Tools
When placing the cursor on top of a monitor, a few tools
will appear:
•
Press this symbol to enter calibration
pages
•
•
Press to solo the monitor
Press to mute the monitor
This is the Main screen from where all other AIR SOFT
screens are accessed.
The (((•))) network icon (upper left corner)
If steady:
The computer running the AIR SOFT is not correctly
connected to AIR monitors. Check connections, cables and
refer to the setup-illustrations on pages 7-13 in this manual.
If blinking:
The computer is correctly connected to your AIR monitor
system.
The (((•))) icon is also used to access the Network screen.
Press (((•))) to access.
VOLUME dialer
Use the mouse on the VOLUME dialer on the middle of the
display to adjust Volume
REF LEV. keys
The three keys below the dialer instantly switches between
the 3 user-defined Reference level settings.
To change these Ref. Levels:
• Set dialer as desired
• Hold cursor above Ref. Level key and select “Store” from
the pop-up icons appearing.
Monitor and Sub icons
Depending on the currently selected setup (if any) satellite
monitors and subs will be indicated by appropriate icons as
illustrated above. Press to access specific parameters for
the monitors.
This symbol in the Main screen indicates that the
selected setup expects a monitor at a certain
position but no monitor is found. Check your
connections and retry.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR SOFT
Preset List
Is accessed by clicking on the left side of the display frame.
Network
Accessing the Network Screen
Press the (((•))) icon in the Main screen to access the
Network facilities. In this screen various global network
settings are handled.
Autodetect
Press to let the AIR SOFT scan your COM ports. If an AIR
System is connected to any port it will be recognized.
Please note that the Autodetect function is not executed
until OK is pressed.
Presets include
• Preset Volume
• Bass Management
• LFE Low Pass
• Parametric EQ
• Mute status
• X-curve setting
• LFE Gain
Port
(can be adjusted using the AIR PC IP only)
All other settings can be considered “global” and are not
stored with presets.
Manual select of Serial/COM port.
Status
Recall presets
Select preset using your mouse and press Recall.
Indicates the status when entering the Network screen.
Clear Network - Clear Setup for entire network
Select this reset procedure to clear all tasks and setup
settings.
Store presets
Select User preset locations 1 to 15 and press Store.
Edit Name
Clear Settings - Clear Monitor Settings
All global and local parameters in connected monitors are
reset. Preset and network settings are not affected.
Any User preset can be renamed.
Set cursor in the name field and edit name using your
keyboard.
Locked symbol in Preset List
Reset to Factory Settings - Reset All Settings
A “factory” reset procedure that deletes all global and local
parameter settings as well as preset and network settings.
Upload Software to Monitors
The “locked symbol” illustrated above indicates that the
preset have been locked via the AIR PC-IP Installers
software. A protection-locked preset cannot be unlocked via
AIR SOFT, - only via AIR PC-IP.
Software updates for the AIR System comes as a .syx - file.
There are separate files for monitors and subs.
• Save the .syx - file to a location on your harddrive prior
to the upload procedure.
• Press Upload Software to Monitors
• Follow the instructions
OK
Press OK to exit window.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR SOFT
During Software upload various messages could be
displayed:
Monitor assignment
Task
• Press monitor symbol to activate pink noise test-tone.
• Then select task for the monitor now playing the noise.
Serial number and type will be indicated.
Example:
In a 5.1 AIR setup you are uploading monitor software to
the entire system. As there are separate software files for
monitors and subs the following message should appear.
A monitor marked with an exclamation mark
indicates that an “unknown” monitor has been
detected.
“5 AIR monitors updated successfully”
- meaning the AIR monitors are updated but no software
has been accepted by the connected sub.
Scan System
Press the magnifying-glass to scan the entire
system for connected units.
If a monitor lost connection during transfer it will not be
indicated or counted, but the software upload continues.
Save Settings
All settings except “preset settings” are saved to a back-up
file.
If the message: “Failed to update AIR monitors” - is
displayed, some of the monitors have reported an error
during software upload. This could be caused by
communication errors. Please retry.
Load Settings
Press and browse to select file to load.
Follow the instructions.
OK
Press to exit screen and execute Autodetect command if
marked.
System Setup
Calibrate - Main Monitors
Solo
Pink Noise
Mute
Configuration
Select your current setup.
Via the Calibrate screen, parameters and settings for the
Main monitors are controlled.
The screen is accessed via the Main Screen by
holding the cursor above the desired monitor and
selecting the hammer icon.
Analog Gain
Range: 9dBu, 15dBu, 21dBu or 27dBu
Set to match analog Input gain to match the signal fed to
the optional Analog Input card.
Room position
Range: Neutral, Wall, Corner, Console, C. Wall or C. Corn
Select according to the actual position of the monitor.
BNC Input
BNC Sync On:
The monitor attempts to lock on the Word Clock BNC.
X Curve
Range: Off, X-Curve 1 or X-Curve-2
Two modifications of X-222 curve are available.
See page 25.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR SOFT
Calibrated Level
Level calibration of the selected monitor.
Polarity
Range: 0 or 180 deg.
Mark to activate.
Relative Level
Preset volume for the selected monitor relative to the
calibrated and global volume.
Calibrated Level
Level calibration of the selected monitor.
Use Parametric EQ
Relative Level
This will be marked if the Parametric EQ is activated via
the AIR PC-IP. Bass and Treble settings will be disabled.
Preset volume for the selected monitor relative to the
calibrated and global volume.
LFE Gain
Range: 0 to 14dB
Bass/Treble
Range: -6dB to +6dB
With this parameter you can boost the gain of the LFE
channel.
Bass and Treble adjustment for the selected monitor.
These handles are not available when the Parametric EQ
is activated via AIR PC-IP.
LFE Low Pass Filter
Mute
Mark to activate.
Press to mute the selected monitor.
Mute
Press to mute the selected Sub.
Solo
Press to solo the selected monitor.
Solo
Press to solo the selected Sub.
Pink Noise
Press to generate Pink Noise in the selected
monitor.
Pink Noise
Press to generate Pink Noise in the selected
Sub.
Calibrate - AIR-Base
Chained monitors
If several monitors are chained on the same task (e.g.
LSur-LSChain) a dropdown menu will be present as
illustrated below.
To calibrate a chained monitor simply select from the list.
Chained monitors will also be indicated in the Main
screen.
Solo
Pink Noise
Mute
This symbol indicates that there are two monitors
chained on this specific position.
Via this Calibrate screen, parameters and settings for the
Subwoofers are controlled.
The screen is accessed via the Main Screen by
holding the cursor above the desired Sub and
selecting the hammer icon.
Phase
Range: 0-180°
To time-compensate if the Sub is not placed according to
the ITU 775 recommendations. There are individual Phase
settings for each of the Bass Management Cross-over
frequencies. Once set, these are stored as Global settings.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
MISCELLANEOUS
The AIR series are unquestionably high quality
products. This section focuses on a few technical
issues that adds to the perception of the high standard
of the products.
Global Parameters
These parameters applies for the entire System:
Global parameters stored with presets
• Bass Management
• Mute Status
High efficiency compact Switched Mode Power Supply
(SMPS)
For saving overhead power consumption and to insure
optimal performance disregarding the mains voltage, the
unit is equipped with a high efficiency compact Switched
Mode Power Supply (SMPS). Using switched technology
both in amplifiers and power supply can reduce the heat
sink size to about 1/3 the size of what it would be with
regular power supply and class AB amplifiers.
Global parameters NOT stored with presets
• Ref. Levels
• Analog Input Sensitivity
• Selected Setup
• BNC Sync
Local Parameters
Power saving shut down modes
The amplifier can detect whether or not there is Input on
the analog or digital line. If input is absent for more than
half an hour all monitors in a network will go to sleep-
mode. from which they can recover automatically when
signal is received. The power up time from sleep is a few
hundred ms.
These parameters applies for individual
monitors:
Local parameters stored with presets
• X-Curve
• Parametric EQ setting (set via AIR PC-IP)
• LFE Gain (subs)
If Input signal is absent for more than 2½ hours the system
will go into standby from which it can recover by user
intervention such as touching the volume wheel on the
Remote Control or by touching the Master monitor display.
• LFE Low Pass (subs)
• Rel. Level
Local parameters NOT stored with presets
• Bass and Treble
• Delay
Software updates
• Lock status (set via AIR PC-IP)
• Room position
• Calibration Level
• Tasks
Each monitor in a setup can be software updated via
Network. This is done through PC/Mac using the AIR
SOFT. Follow the Software update procedure as described
• Phase (Subs)
• Polarity (Subs)
Reset Procedures
Three different levels of “Reset” exists. For all three
scenarios all connected monitors will be affected.
The following Reset procedures are accessed by
holding the ENTER key on the System Controller while
powering up:
Clear Monitor Settings
All global and local parameters in connected monitors are
reset. Preset and network settings are not affected.
Reset all Settings
A “factory” reset procedure that deletes all global and local
parameter settings as well as preset and network settings.
The following reset procedure is found in the Setup
menu:
Clear Setup for entire network
Select this reset procedure to clear all network settings.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
CABLES
TC LINK Standard Cat-5 cables
Maximum Cable Length : 15 meter.
Cable type
: Shielded Ethernet Cable
Category 5.
Connector type
: RJ45
This connection is carrying Digital audio (24 bit) and
network control information.
Serial to Cat-5 cable
- included with the AIR SOFT and AIR
PC-IP. This is a proprietary cable with
build in electronics for use with AIR
Systems only !
P1
P1
1
P2
1
Color
Brown
2
2
White/Brown
Green
3
3
4
4
White/Blue
Blue
5
5
6
6
White/Green
Orange
7
7
8
8
White/Orange
P2
AES/EBU Standard cables
USB to COM 9pin
Maximum Cable Length: 100 m
- NOT included with AIR SOFT or AIR
PC-IP. Use this type of converter in
Cable type:
110 Ohm
XLR
Connector type:
conjunction with the Cat5 to Serial cable
described above if your computer has a
USB connection only and no serial port.
XLR - XLR
Pin 1 - Pin 1 (Ground)
Pin 2 - Pin 2 (Hot)
Pin 3 - Pin 3 (Cold)
52
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR TECHNICAL SPECIFICATIONS
AIR 6 & AIR 15 (Master and Slave)
Model
AIR 6
AIR 15
System
Two-way Active Nearfield Monitor
40 Hz – 22 kHz
> 128 dB peak
> 126 dB peak
104 dB RMS
+/- 0.2 dB
45 Hz
12.1 liters
Bass reflex
Two-way Active Nearfield Monitor
33 Hz – 22 kHz
> 128 dB peak
> 126 dB peak (no LFE)
103 dB RMS
+/- 0.2 dB
40 Hz
27 liters
Bass reflex
Frequency response (+/- 3 dB)
Peak SPL 1m, pair (IEC Short Term)
Peak SPL 2m, 5.1 (IEC Short Term)
Max SPL 1m, (IEC Long Term)
Precision of monitor matching
Port tuning frequency
Internal cabinet volume
Bass principle
Crossover frequency
Crossover slope
Tweeter
2150 Hz (DSP generated)
24 dB/oct (Linkwitz Riley, DSP generated)
Esotec 28 mm / 1.1" soft dome, rear chamber, magnetic fluid,
4mm die-cast alu front, pure alu wire voice coil
175 mm / 6.5", one-piece molded polyprop cone, 75 mm / 3"
pure alu voice coil, magnetic shielded
100 to 240 VAC, 50 to 60 Hz (auto-select)
40 W @ 1/8 max power (IEC 60065)
2150 Hz (DSP generated)
24 dB/oct (Linkwitz Riley, DSP generated)
Esotec 28 mm / 1.1" soft dome, rear chamber, magnetic fluid,
4mm die-cast alu front, pure alu wire voice coil
240 mm / 10", one-piece molded polyprop cone, 100 mm / 4"
pure alu voice coil
Woofer
Mains voltage
Power consumption
100 to 240 VAC, 50 to 60 Hz (auto-select)
40 W @ 1/8 max power (IEC 60065)
Finish
Amp
Cabinet
Dimensions (H x W x D)
Weight
Black anodized aluminum back plate
Dark gray MDF baffle, Silver foil
338 x 216 x 345mm / 13,3” x 8,5” x 13,6”
9.8 kg / 21.8 lbs
Black anodized aluminum back plate
Dark gray MDF baffle, Silver foil
425 x 275 x 395mm / 16,7” x 10,8” x 15,5”
15.5 kg / 34.5 lbs
Amplifier
Tweeter and woofer
Tweeter 200 W PWM amp/Woofer 200 W PWM amp
Tweeter 200 W PWM amp/Woofer 200 W PWM amp
AIR 20 & AIR 25 (Master and Slave)
Model
AIR 20
AIR 25
System
Three-way Semiactive Nearfield Monitor
31 Hz –22 kHz: +/- 3dB
131 dB peak
129 dB peak
104 dB RMS
+/- 0.2 dB
40 Hz
35 liters
Bass reflex
Three-way Active Nearfield Monitor
28 Hz –22 kHz: +/- 3dB
134 dB peak
132 dB peak
107 dB RMS
+/- 0.2 dB
35 Hz
68 liters
Frequency response (+/- 3 dB)
Peak SPL 1m, pair (IEC Short Term)
Peak SPL 2m, 5.1 (IEC Short Term)
Max SPL 1m, (IEC Long Term)
Precision of monitor matching
Port tuning frequency
Internal cabinet volume
Bass principle
Bass reflex
Crossover frequency
Crossover slope
390 Hz (DSP generated) and 2600 Hz
12 dB/oct and 6 dB/oct
400 Hz (DSP generated) and 2400 Hz (DSP generated)
Tweeter
Esotar 28 mm / 1.1” soft dome, neodymium magnet, rear chamber, Esotar 28 mm / 1.1” soft dome, neodymium magnet, rear cham-
magnetic fluid, 4mm steel front, pure alu wire voice coil
145 mm / 5,5", one-piece molded polyprop cone, 38 mm / 1,5"
pure alu voice coil
240 mm / 9,5", one-piece molded polyprop cone, 100 mm / 4"
pure alu voice coil
ber, magnetic fluid, 4mm steel front, pure alu wire voice coil
145 mm / 5,5", one-piece molded polyprop cone, 38 mm / 1,5"
pure alu voice coil
2x240 mm / 9,5", one-piece molded polyprop cone, 100 mm /
4" pure alu voice coil
Midrange
Woofer
Mains voltage
Power consumption
100 to 240 VAC, 50 to 60 Hz (auto-select)
45 W @ 1/8 max power (IEC 60065)
100 to 240 VAC, 50 to 60 Hz (select)
45 W @ 1/8 max power (IEC 60065)
Finish
Amp
Cabinet
Dimensions (H x W x D)
Depth incl. amp and driver:
Weight
Black painted back plate
Black painted back plate
Black ash with dark gray MDF baffle
510 x 535 x 450 mm /20” x 21” x 17,7”
490mm / 19,3”
Black ash with dark gray MDF baffle
575 x 310 x 395 mm / 22,6” x 12,2” x 15,5”
435mm / 17,0”
28 kg / 62.2 lbs
46 kg / 101 lbs
Amplifier
Tweeter, midrange and woofer
Tweeter & Midrange 200 W amp/Woofer 200 W amp
Tweeter 300 W amp/Midrange 300 W amp/Woofer 2x300 W amp
53
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR TECHNICAL SPECIFICATIONS
AIR-Base-1 & AIR-Base-2
System:
Active Subwoofers
Total frequency response:
25 Hz – bssmng: 120 Hz, LFE: 2.5 kHz/
23 Hz – bssmng: 120 Hz, LFE: 2.5 kHz : +/-3dB
119 dB peak / 121 dB peak
113 dB peak / 115 dB peak (no front, rear & center)
+/- 0.2 dB
Max. SPL 1m, one (IEC Short Term)
Max. SPL 2m, 5.1 (IEC Short Term)
Precision of monitor matching:
Port tuning frequency:
30 Hz / 27 Hz
Internal cabinet volume:
Bass principle:
37 liters / 78 liters
Bass reflex
Woofer:
1 / 2 pcs. 240 mm / 10", one-piece molded polyprop cone, 100
mm / 4" pure alu voice coil
Mains voltage:
Power consumption:
100 to 240 VAC, 50 to 60 Hz (auto-select)
40 W @ 1/8 max power (IEC 60065)
Finish
Amp:
Cabinet:
Black anodized aluminum back plate
Dark gray MDF baffle, Silver foil
Dimensions (H x W x D):
310 x 480 x 420mm / 900 x 310 x 420mm
(12.2” x 18,9” x 16.5” / 35.4” x 12.2” x 16.5”)
Depth incl. amp and driver: 447mm / 447mm (17.6” / 17.6”)
18 kg / 29 kg (39.6 lbs / 63.8 lbs)
250 W PWM amp
Weight:
Amplifier
AIR Base 12
System:
AIR Base 12
Total frequency response:
Max. SPL 1m, one (IEC Short Term)
Max. SPL 2m, 5.1 (IEC Short Term)
Precision of monitor matching:
Port tuning frequency:
Internal cabinet volume:
Bass principle:
Active Subwoofer
22 Hz – 200 Hz +/- 3 dB, dep. on setting
123dB peak
117dB peak
+/- 0.2 dB
24 Hz
41 litres
Woofer:
Bass reflex. Downfiring port
1 pcs. 300 mm/12", two-piece molded poly-
prop cone, 75 mm/3" pure copper voice coil
100 to 240 VAC, 50 to 60 Hz (select)
Idle: 50 W/Max: 375 W
Mains voltage:
Power consumption:
Finish
Amp:
Cabinet:
Dimensions (H x W x D):
Black painted metal back plate
Black ash with dark gray MDF baffle
460 x 360 x 502mm (18.1 x 14.2 x 19.7)
Depth incl. amp and driver: 550 mm (not moving) Height incl. “feet”:
738
Weight:
Amplifier
38 kg (83.8 lbs)
500 W amp
AIR Base 24
System:
AIR Base 24
Total frequency response:
Max. SPL 1m, one (IEC Short Term)
Max. SPL 2m, 5.1 (IEC Short Term)
Precision of monitor matching:
Port tuning frequency:
Internal cabinet volume:
Bass principle:
Active Subwoofer
20 Hz – 200 Hz +/- 3 dB, dep. on setting
126dB peak
120 dB peak
+/- 0.2 dB
22 Hz
77 litres
Woofer:
Bass reflex. Downfiring port
2 pcs. 300 mm/12", two-piece molded poly-
prop cone, 75 mm/3" pure copper voice coil
100 to 240 VAC, 50 to 60 Hz (select)
Idle: 50 W/Max: 375 W
Mains voltage:
Power consumption:
Finish
Amp:
Cabinet:
Dimensions (H x W x D):
Black painted metal back plate
Black ash with dark gray MDF baffle
720 x 360 x 502mm (28.3 x 14.2 x 19.7)
Depth incl. amp and driver: 550 mm (not moving) Height incl. “feet”:
738
Weight:
Amplifier
60 kg (132.3 lbs)
700 W amp
54
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR TECHNICAL SPECIFICATIONS
Room & Distance
Typical listening distance
AIR 6
1.2-2 m / 4-7 ft
Typical room size
AIR 6
AIR 15
1.5-2.5 m / 5-8,5 ft
AIR 20
1.5-3 m / 5-10.2 ft
AIR 25
AIR 25
AIR 15
AIR 20
50-100 m3 / 1600-3500 ft
AIR-Base-1
30-60 m3 / 1000-2000 ft3
75-125 m3 /2600-4400 ft
AIR-Base-2
50-100 m3 / 1600-4400 ft3
80-130 m3 / 2800-4600 ft3
Two or three AIR-Base-1’s
50-100 m3 / 1600-3500 ft3
Two or three AIR-Base-1’s
75-125 m3 / 2600-4400 ft3
General specifications for AIR 6, AIR 15, AIR 20, AIR 25, AIR-Base-1, AIR-Base-2, AIR-Base 12 & AIR Base 24
System sample rates
Internal sample rate
192 and 176.4 via Dual Wire (optional Digital Card required) and
96, 88.2, 64, 48, 44.1 or 32 kHz
AIR Masters only
I/O Connectors
Formats
XLR (2 channels AES/EBU in) 3 x RJ45 proprietary TC LINK
AES/EBU (24 bit)
Word clock input
Display
BNC, 75 ohm, 0.6 to 10 Vpp
2 x 16 character dot matrix
Operation
Menu system / four buttons
Analog input option
Input connectors
Impedance
Selectable full scale input level
Dynamic Range
THD+N
XLR balanced (pin 2+, pin 3-)
10/3 k Ohm (Balanced/unbalanced)
+9, +15, +21, +27 dBu
> 113 dB typ. (unweighted), BW: 20-20kHz
< -105 dB typ. @ 1 kHz, -3 dBFS
< -120 dB, 20 Hz to 20 kHz
Crosstalk
A to D Conversion
24 bit (Dual bit delta sigma sampling at 4.1/5.6/6.1/6.1 MHz)
AIR Slaves only
I/O Connectors
2 x RJ45 proprietary TC LINK
General for all Products
EMC complies with:
Safety certified to:
EN 55103-1 and EN 55103-2, FCC part 15 class B, CISPR 22 class B
IEC 60065, EN 60065, UL 6500 and CSA E60065 CSA FILE
#LR108093
Environment operating Temperature:
Storage Temperature:
Humidity:
32° F to 122° F (0° C to 50° C)
-22° F to 167° F (-30° C to 70° C)
Max. 90 % non-condensing
Warranty
2 years on parts and labor
AIR Remote specs
AIR Remote
Finish:
Black anodized aluminum and plastic
Dimensions (D x W x H):
Weight:
120 x 70 x 35 mm
250g
I/O Connectors:
1 x RJ45 proprietary TC LINK
EMC
Complies with:
EN 55103-1 and EN 55103-2,
FCC part 15 class B, CISPR 22 class B
Safety
Certified to:
IEC 60065, EN 60065, UL 6500 and CSA E60065
CSA FILE #LR108093
Environment
Operating Temperature:
Storage Temperature:
Humidity:
32° F to 122° F (0° C to 50° C)
-22° F to 167° F (-30° C to 70° C)
Max. 90 % non-condensing
Warranty
Parts and labor:
1 year on parts and labor
55
Download from Www.Somanuals.com. All Manuals Search And Download.
DELAY IN SYSTEM & ERROR MESSAGES ETC.
Sample Rate
(AES or WC In)
Digital Input
Analog Input *)
Converter
kHz
Samples @ msec
Input Rate
centimeter Samples @
msec
centimeter
kHz
Converter Rate
93.00
68.00
40.00
34.00
34.00
34.00
2.91
1.54
0.83
0.53
0.39
0.35
100
53
29
18
13
12
73.00
73.00
73.00
73.00
73.00
73.00
1.14
0.83
0.76
1.14
0.83
0.76
39
28
26
39
28
26
32.00
44.10
48.00
64.00
88.20
96.00
64.00
88.20
96.00
64.00
88.20
96.00
*): In Analog Input mode without WC Input selected, the system runs on the Master monitor's own 96kHz clock.
Standby
Error messages etc.
Displayed when no Input signal has been detected for
more than 30 min. below -65 dB. The Amplifier is turned
off. Standby mode is released as soon a signal level above
The "!" indicates that the monitor is not connected to the
-65dB has been detected.
"!" as "96 kHz Center!”
network. The volume is then automatically set to -50 dB for
the monitor not recognized.
>> Power save <<
Displayed when no signal has been detected on all
"+" as "96 kHz L Front+":
monitors on network for more than 2½ hours. Power is
The "+" indicates that the monitor you are looking at is the
turned off. Exit this mode by pressing any key on system
System Controller.
controller or adjusting volume from remote.
>> A-Input Lo <<
This is displayed in analog setups only and indicates that
the Input level has been detected to be between -60dB and
-20dB for a period longer than 3 minutes. This is a hint to
turn up the Analog Input Gain
Analog Input gain range:
+9dBu, +15dBu, +21dBu or 27 dBu.
>> A-Input Hi <<
This is displayed in analog setups only and indicates that
an Input level near 0dB is detected. (peaks in 2 sec. above
-1 dB). This is a warning and you should turn down the
Analog Input gain range:
+9dBu, +15dBu, +21dBu or 27 dBu.
>> PSU error <<
Displayed if the power supplies fails. The power will be
turned off and the monitor cannot operate. Please get in
touch with the TC Electronic Support Team via
<Locked>
Displayed when a parameter is locked by the installer
software and cannot be changed.
Parameter lock can only be unlocked with AIR IP software.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
CERTIFICATE OF CONFORMITY
Certificate Of Conformity
TC Electronic A/S, Sindalsvej 34, 8240 Risskov,
Denmark, hereby declares on own responsibility that
following products:
AIR 6
AIR 15
AIR 20
AIR 25
AIR-Base 1
AIR-Base 2
AIR-Base 12
AIR-Base 24
AIR REMOTE
- that are covered by this certificate and marked with
CE-label conforms with following standards:
EN 60065
(IEC 60065)
Safety requirements for mains
operated electronic and related
apparatus for household and similar
general use
EN 55103-1
EN 55103-2
Product family standard for audio,
video, audio-visual and entertainment
lighting control apparatus for
professional use. Part 1: Emission.
Product family standard for audio,
video, audio-visual and entertainment
lighting control apparatus for
professional use. Part 2: Immunity.
With reference to regulations in following directives:
73/23/EEC, 89/336/EEC
Issued in Risskov, December 2002
Mads Peter Lübeck
Chief Executive Officer
57
Download from Www.Somanuals.com. All Manuals Search And Download.
PRESET LIST
58
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Contemporary Research TV Receiver IP HDVR User Manual
Craftsman Chipper 24777588O User Manual
Delta Electronics Power Supply SIA3220 User Manual
Dimplex Indoor Fireplace VCX1525 User Manual
Earlex Paint Sprayer V0053 User Manual
Edimax Technology Satellite TV System EA MARS User Manual
Garland Convection Oven TE3 4 User Manual
Garland Range PS 12G 2 20 User Manual
Gateway Computer Monitor FPD1976W User Manual
GE Double Oven jk910 User Manual