Dimplex Indoor Fireplace V1525BT User Manual

PRACTICAL USER’S GUIDE  
FOR THE IN-STUD FIREPLACE  
MODEL NUMBER:  
V1525BT  
V1525RT  
Serial Number _______________  
Quality checked by:  
Model Number _______________  
Valued Customer,  
We are pleased that you have chosen to purchase an  
electric fireplace manufactured by Dimplex North America  
Limited.  
Over the years, valuable memories will occur around the  
warmth and comfort of your hearth. Thank you for allowing  
our product to be the backdrop for those special moments.  
7208630100R01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT INSTRUCTIONS  
RETAIN THIS USER’S GUIDE  
FOR FUTURE REFERENCE  
When using electrical appliances, basic  
precautions should always be followed to reduce  
the risk of fire, electric shock, and injury to persons.  
1. Read all instructions before using the In-Stud  
fireplace.  
2. The heater is hot when in use. To avoid burns,  
do not let bare skin touch hot surfaces. The  
trim around the heater outlet becomes hot  
during heater operation. Keep combustible  
materials, such as furniture, pillows, bedding,  
papers, clothes, and curtains at least 3 feet  
(0.9m) from the front of the unit.  
3. Extreme caution is necessary when any heater  
is used by or near children and whenever the  
unit is left operating and unattended.  
4. Always disconnect power to the fireplace when  
not in use for extended period of time.  
5. Do not operate with a damaged cord or plug (for  
units supplied with a cord), or if the heater has  
malfunctioned, or if the fireplace has been  
dropped or damaged in any manner. Contact  
Dimplex Customer Services 1-888-346-7539  
immediately.  
6. Do not use outdoors.  
7. Never locate heater where it may fall into a  
bathtub or other water container.  
8. Do not run the cord under carpeting (for units  
supplied with a cord). Do not cover cord with  
throw rugs, runners, or the like. Arrange cord  
away from traffic area and where it will not be  
tripped over.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. To disconnect the unit, turn the controls off, and  
then remove the plug from the outlet or switch  
off at main power supply panel if the unit is  
hardwired.  
10. Do not insert or allow foreign objects to enter  
any ventilation or exhaust opening as this may  
cause an electric shock or fire, or damage to  
the heater.  
11. To prevent a possible fire, do not block air intake  
or exhaust in any manner.  
12. All electrical heaters have hot and arching or  
sparking parts inside. Do not use in areas  
where gasoline, paint, or flammable liquids are  
used or stored or where the unit will be exposed  
to flammable vapors.  
13. Do not modify the fireplace. Use it only as  
described in this manual. Any other use not  
recommended by the manufacturer may cause  
fire, electric shock or injury to persons.  
14. This unit may have a polarized plug (one blade  
is wider than the other). The plug will fit in a  
polarized outlet only one way. If the plug does  
not fit fully in the outlet, reverse the plug. If it still  
does not fit, contact a qualified electrician to  
install the proper outlet. Do not change the plug  
in any way. Avoid the use of an extension cord.  
Extension cords may overheat and cause a risk  
of fire. If you must use an extension cord, the  
cord must be No. 16 AWG minimum size and  
rated no less than 1875 watts.  
15. Do not burn wood or other materials in the  
fireplace.  
16. Do not strike the glass front.  
17. Always use a certified electrician for build-in  
hard-wired installation.  
18. Always use properly grounded, fused and  
polarized outlets.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
19. Disconnect all main power supply (unplug the  
unit or switch off at main service panel) before  
performing any cleaning, maintenance or  
relocation of the unit.  
20. Do not operate the fireplace without the glass  
assembly and/or frame.  
21. When transporting or storing the unit and cord,  
keep in a dry place, free from excessive  
vibration and store so as to avoid damage.  
22. Do not put combustible material, liquid, small  
articles such as sand inside glass assembly.  
SAVE THESE  
INSTRUCTIONS  
If you have any questions about our products please  
have the product model and serial numbers available  
upon calling Dimplex customer service. To locate the  
model and serial number see below.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: Procedures and techniques that are  
considered important enough to emphasize.  
CAUTION: Procedures and techniques, which, if not  
carefully followed, will result in damage to the  
equipment.  
WARNING: Procedures and techniques, which, if not  
carefully followed, will expose the user to the risk of  
fire, serious injury, illness or death.  
Step-by-Step Installation  
NOTE  
A 15amp, 120-volt circuit is required. A dedicated  
circuit is preferred but not essential in all cases. A  
dedicated circuit will be required if, after installation, the  
circuit breaker trips or the fuse blows on a regular  
basis when the heater is operating. Additional  
appliances on the same circuit may exceed the current  
rating of the circuit breaker.  
WARNING  
Ensure the power cord is not installed so that it is  
pinched or against a sharp edge and ensure that the  
power cord is stored or secured to avoid tripping or  
snagging to reduce the risk of fire, electric shock or  
injury to persons.  
Construction and electrical outlet wiring must comply  
with local building codes and other applicable  
regulations to reduce the risk of fire, electric shock and  
injury to persons.  
Do not attempt to wire your own new outlets or circuits.  
To reduce the risk of fire, electric shock or injury to  
persons, always use a licensed electrician.  
WARNING  
The In-Stud fireplace is wall mountable and can be  
build-in the wall space 16" over-center between 2"x4"  
wall studs. Follow the installation instructions for either  
wall mount or built-in mounting; failure to do so may  
cause damage or injury.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remove glass assembly before installing fireplace  
on or into a wall.  
1. Remove screws securing glass assembly on  
the mounting tabs. (Figure 1)  
2. Use both handles on the sides of the glass  
assembly, lift and remove the assembly from  
the fireplace.  
3. Please glass assembly with it’s back facing  
down on a flat surface.  
Wall Mounting Instructions:  
1. Leave the trim uninstalled until step 9.  
2. Select a location for the fireplace, preferably  
above an electrical outlet and there must be at  
least one wall stud behind for the fireplace to  
mount onto. The bottom of the unit must be a  
minimum of 4" space above the floor (mounting  
holes 29.5" minimum above the floor). Access to  
the electrical outlet must be maintained. Ensure  
the installation meets the national and state/  
provincial electrical codes.  
FIGURE 1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2  
NOTE  
It is recommended that the bottom of the unit not be  
mounted higher than 48" from the ground to  
maintain an optimized viewing angle of the flame.  
CAUTION  
The fireplace must be mounted at two points, one  
of which must be on a wall stud.  
WARNING  
High temperatures may be generated under  
certain abnormal conditions. Do not partially or  
fully cover or obstruct the front of this heater.  
Bottom of unit must be a minimum of 4" above  
floor or any surface such as a tabletop to ensure  
adequate ventilation through air intake located at  
the bottom of the fireplace. (Figure 3)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Circulation  
Figure 3  
3. With a wall stud finder, locate the center of the  
wall stud, drive a wood screw into stud and  
leave approximately 1/8" exposed threads for  
the fireplace to hang on.  
4. The second mounting point should be picked  
such that it is farthest (to the left or right)  
relative to the first one among the seven  
keyholes (A to G shown in figure 2) on the  
fireplace for wall mounting, these keyholes  
are 2" apart. For example, if you plan to use  
hole B as the first mounting hole, the second  
mounting hole must be G. Other available  
combinations are A-G, C-G, A-F, A-E, A-D and  
D-G.  
5. Mark the second mounting screw location;  
ensure that is level with the first with the help  
of the provided bubble level and the fireplace  
itself. Screw the threaded drywall anchor in  
the drywall with a Philip’s head screwdriver  
until the head is flat against the wall surface.  
Caution should be taken when using a power  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
tool to install a threaded drywall anchor as the  
drywall may distort, tear or slightly buckle as a  
result of over-torque.  
6. With a Philip’s head screw driver, screw that  
drywall anchor screw into the drywall anchor  
already in the wall, leave about 1/8" exposed  
threads for mounting the fireplace.  
7. With the glass assembly taken off, mount the  
firebox onto the two mounting screws.  
8. Tighten both mounting screws with a  
screwdriver. Be caution not to over tighten  
the one mated with the drywall anchor.  
9. Screw supplied wood screw into  
corresponding hole that aligns with stud.  
(Fig. 2)  
10. Re-install glass assembly into fireplace.  
11. Install frame onto the firebox as shown in  
below.  
Figure 4  
Install supplied  
brackets as shown  
on bothsides of  
Install frame on to  
frame  
fireplace  
Secure frame on  
fireplace with  
supplied self-tapping  
screws  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Built-In Instructions:  
WARNING  
The installation of the fireplace unit must comply  
with the applicable local and/or national electrical  
codes and utility requirements. This installation  
should be entrusted to duly qualified personnel  
where required by law.  
1. Leave the frame uninstalled from the fireplace  
chassis until step 13.  
2. Prepare a wall opening following the dimen-  
sions shown in Figure 5. Note that 4" minimum  
depth including thickness of dry wall is  
required. Make sure there is enough clearance  
for the cable coming out from the bottom of the  
fire place.  
Figure 5  
NOTE  
Where there are close tolerances involved in wall  
building or applications which require a great  
degree of precision, we recommend that the  
product itself be used to make the actual  
measurements for the wall opening. Dimplex North  
America will not be responsible for inaccuracies in  
the design or manufacture of enclosures.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING  
Ensure method of installation does not obscure the  
air intake slots on bottom of unit in any manner.  
Keep minimum 4" clearance from bottom of unit to  
any surface such as the top of a cabinet.  
3. Wire a dedicated, properly fused circuit with  
120V, 15amp rating. Allow up to 8 feet of service  
cable for connecting power supply to junction  
box on fireplace when installing after finishing  
wall.  
CAUTION  
Use two conductor, non-metallic sheath cable with  
ground wire (3 wires total) for the incoming power  
supply on fireplace inserts. Use appropriate wire to  
meet local and national electrical codes for rated  
power consumption.  
4. Remove the outer jacket and strip the individual  
conductor from the end.  
5. Loosen the screw securing the junction box  
cover and remove the cover.  
6. Take the cables out from the junction box,  
loosen the two wire twist nuts and remove the  
cord set. (FIGURE 6.)  
Figure 6  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 7  
7. Route the power supply wire through the  
knockout on supplied alternative junction box  
cover and secure with a wire clamp (not  
supplied) (FIGURE 7.)  
8. Connect the black wire (live) from the unit to the  
black wire from power supply. (FIGURE 7.)  
9. Connect the white wire (neutral) from the unit to  
the white wire from power supply. (FIGURE 7.)  
10. Connect the green wire (ground) from the unit  
to the green wire from power supply.  
(FIGURE 7.)  
WHITE WIRE (N)  
BLACK WIRE (L)  
GREEN WIRE (G)  
WHITE WIRE (N)  
BLACK WIRE (L)  
GREEN WIRE (G)  
FIREPLACE  
JUNCTION  
BOX  
120V  
POWER  
SUPPLY  
(BREAKER  
PANEL)  
11. Place all connectors inside the unit and secure  
the junction box cover to unit. Ensure that the  
cable clamp grips only the jacket of service  
cable.  
NOTE  
All wiring must be completed prior to installing  
the unit into the wall.  
12. Place unit in position in the opening, push  
straight in and attach unit to studs using No. 10  
fasteners. Attach supplied wall cover brackets  
to the top and the bottom of fireplace to cover  
the gap on the dry wall (Figure 8)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 8  
13. Attach fireplace frame as shown in figure 4.  
Bathroom Installation  
This firebox must be protected by a GFI receptacle or  
circuit for bathroom use. If receptacle is used it must  
be readily accessible.  
This unit is an electrical appliance that is not watertight  
and must be installed as to prevent water from entering  
the unit to prevent electrical shock. This unit must be  
installed away from showers, tubs, etc.  
Never locate fireplace where it may fall into a bathtub or  
other water containers. Keep towels and other  
combustible materials 3 feet away from the front of the  
unit.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
The controls are located on the right hand side of  
the fireplace. Figure 9.  
A. MAIN ON/OFF SWITCH  
Thermostat  
Heater ON/OFF Switch  
Main ON/OFF Switch  
Figure 9  
The switch has two ON positions marked  
with  
and “ON”.  
The “ON” position is for manual operation. In this  
position the built-in remote control is by-passed.  
The  
position is for operating the unit with the  
provided remote control.  
When in  
position the unit is operated with the ON  
and OFF buttons of the remote control.  
When the switch is in the center position the unit is off.  
B. Heater On Switch  
The HEAT ON/OFF SWITCH supplies power to the  
heater fan and the heater element.  
When the switch is in the ON position the heater  
operates if the thermostat calls for heat.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C. Heater Thermostat Control  
To adjust the temperature to your individual  
requirements, turn the thermostat control upward  
all the way to turn on the heater. When the room  
reaches the desired temperature, turn the  
thermostat knob downward until you hear a click.  
Leave in this position to maintain the room  
temperature at this setting. For additional heat, turn  
upward until you hear the click again and the heater  
will turn on.  
Resetting The Temperature Cutoff  
Switch  
Should the heater overheat, an automatic cut out will  
turn the fireplace off and it will not come back on  
without being reset. It can be reset by switching the  
Main ON/OFF switch to OFF and waiting 5 minutes  
before switching the unit back on.  
CAUTION  
If you need to continuously reset the heater, disconnect  
power and call Dimplex customer service at 1-888-  
DIMPLEX (1-888-346-7539).  
Remote Operation  
The Fireplace is supplied with an integrated on/off  
remote control  
Note: Ensure that the fireplace Main ON/OFF  
switch is set to the remote  
Control setting.  
To operate, push the ON button to turn fireplace on,  
push the OFF button o turn the fireplace off.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Battery Replacement  
To replace the battery, slide battery cover open on the  
hand held transmitter.  
Install one 12-volt (A23) battery in the battery holder.  
Close the battery cover.  
Off Button  
On Button  
Battery  
Battery  
Cover  
Maintenance  
WARNING  
Disconnect power before attempting any maintenance  
or cleaning to reduce the risk of fire, electric shock or  
damage to persons.  
Light Bulb Replacement  
Turn unit off, allow at least 5 minutes for light bulbs to  
cool before touching bulbs to avoid accidental burning  
of skin.  
Light bulbs need to be replaced when you notice a dark  
section of the flame or when the clarity and detail of the  
log exterior disappears. There are two bulbs, which  
generate the flames and embers.  
Tool Requirements  
Philips screw driver  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Helpful Hints  
It is a good idea to replace all light bulbs at one time if  
they are close to the end of their rated life. Group  
replacement will reduce the number of times you need  
to open the unit to replace light bulbs.  
Light Bulb Requirements  
Quantity of two 40W Chandelier or candelabra bulbs  
with E-12 (small) socket base, 120 Volt.  
DO NOT EXCEED 40 WATTS PER BULB  
Bulb Replacement Instructions:  
1. Disconnect power supply to the fireplace either by  
unplugging the fireplace or switch off at the breaker  
panel.  
2. Remove fireplace front trim.  
3. Remove glass assembly. Remove the screws  
securing the glass assembly on the chassis. Hold  
on to the handles on the glass assembly with both  
hands then lift the whole assembly straight up to  
remove. Figure 10.  
4. Remove the two screws securing the light block as  
shown in Figure 11, then remove the light block.  
5. Reach in and turn the burnt-out bulb(s) counter-  
clockwise to remove.  
6. Replace with new bulbs.  
7. Reassemble light block, glass assembly and  
fireplace frame in reverse order.  
Glass Assembly  
Handle  
Handle  
LIFT TO  
REMOVE  
Figure 10  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Light Block  
Figure 11  
Glass Cleaning  
The front glass is cleaned in the factory during the  
assembly operation. During shipment, installation,  
handling, etc., the front glass may collect dust  
particles, these can be removed by dusting lightly with  
a clean dry cloth.  
To remove fingerprints or other marks, the glass can be  
cleaned with a damp cloth. The glass should be  
completely dried with a lint free cloth to prevent water  
spots. To prevent scratching, do not use abrasive  
cleaners or spray liquids on the glass surface.  
Fireplace Surface Cleaning  
To remove fingerprints or other marks, the exterior  
finish can be cleaned with a damp cloth with a mild  
detergent. The surface should be completely dried with  
a lint free cloth to prevent water spots.  
To prevent scratching, do not use abrasive  
cleaners or spray liquids on any surface.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OneYear Limited Warranty  
Products to which this limited warranty applies  
This limited warranty applies to newly purchased Dimplex  
fireplaces and surrounds (mantels) and trims. This limited  
warranty applies only to purchases made in any province of  
Canada except for Yukon Territory, Nunavut, or Northwest  
Territories or in any of the 50 States of the USA (and the  
District of Columbia) except for Hawaii and Alaska. This  
limited warranty applies to the original purchaser of the  
product only and is not transferable.  
Products excluded from this limited warranty  
Light bulbs are not covered by this limited warranty and are  
the sole responsibility of the owner/purchaser. Products  
purchased in Yukon Territory, Nunavut, Northwest  
Territories, Hawaii, or Alaska are not covered by this  
limited warranty. Products purchased in these States,  
provinces, or territories are sold AS IS without warranty or  
condition of any kind (including, without limitation, any  
implied warranties or conditions of merchantability or  
fitness for a particular purpose) and the entire risk of as to  
the quality and performance of the products is with the  
purchaser, and in the event of a defect the purchaser  
assumes the entire cost of all necessary servicing or  
repair.  
What this limited warranty covers and for how long  
Products covered by this limited warranty have been tested  
and inspected prior to shipment and, subject to the provisions  
of this warranty, Dimplex warrants such products to be free  
from defects in material and workmanship for a period of 12  
months from the date of the first purchase of such product.  
The limited 12 month warranty period also applies to any  
implied warranties that may exist under applicable law.  
Some jurisdictions do not allow limitations on how long an  
implied warranty lasts, so the above limitation may not apply  
to the purchaser.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
What this limited warranty does not cover  
This limited warranty does not apply to products that have  
been repaired (except by Dimplex or its authorized service  
representatives) or otherwise altered. This limited warranty  
does further not apply to defects resulting from misuse,  
abuse, accident, neglect, incorrect installation, improper  
maintenance or handling, or operation with an incorrect power  
source.  
What you must do to get service under this limited warranty  
Defects must be brought to the attention of Dimplex Technical  
Service by contacting Dimplex at 1-888-DIMPLEX (1-888-346-  
7539), or 1367 Industrial Road, Cambridge Ontario, Canada  
N1R 7G8. Please have proof of purchase, catalogue/model  
and serial numbers available when calling. Limited warranty  
service requires a proof of purchase of the product.  
What Dimplex will do in the event of a defect  
In the event a product or part covered by this limited warranty  
is proven to be defective in material or workmanship during  
the 12 month limited warranty period you have the following  
rights:  
§
Dimplex will in its sole discretion either repair or  
replace such defective product or part without charge.  
If Dimplex is unable to repair or replace such product  
or part, or if repair or replacement is not commercially  
practicable or cannot be timely made, Dimplex may, in  
lieu of repair or replacement, choose to refund the  
purchase price for such product or part.  
§
§
Limited warranty service will be performed solely by  
dealers or service agents of Dimplex authorized to  
provide limited warranty services.  
The purchaser is responsible for removal and  
transportation of such product or part (and any repaired  
or replacement product or part) to and from the  
authorized dealer’s or service agent’s place of  
business.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
§
§
This limited warranty does not entitle the purchaser to  
on-site or in-home services. On-site or in-home  
services may be performed at the purchaser’s specific  
request and expense at Dimplex’s then-current rates  
for such services.  
Dimplex will not be responsible for, and the limited  
warranty services shall not include, any expense  
incurred for installation or removal of the product or part  
(or any replacement product or part) or any labour or  
transportation costs. Such costs shall be the  
purchaser’s responsibility.  
What Dimplex and its dealers and service agents are also  
not responsible for:  
IN NO EVENT WILL DIMPLEX, OR ITS DIRECTORS,  
OFFICERS, OR AGENTS, BE LIABLE TO THE  
PURCHASER ORANY THIRD PARTY, WHETHER IN  
CONTRACT, IN TORT, OR ON ANY OTHER BASIS, FOR  
ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY,  
CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR  
DAMAGE ARISING OUT OF OR IN CONNECTION WITH  
THE SALE, MAINTENANCE, USE, OR INABILITY TO USE  
THE PRODUCT, EVEN IF DIMPLEX OR ITS DIRECTORS,  
OFFICERS, OR AGENTS HAVE BEEN ADVISED OF THE  
POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES,  
OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE  
FORESEEABLE. IN NO EVENT WILL DIMPLEX, OR ITS  
OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR  
ANY DIRECT LOSSES, COSTS, OR DAMAGES THAT  
EXCEED THE PURCHASE PRICE OF THE PRODUCT.  
SOME JURISDICTIONS DO NOTALLOW THE EXCLUSION  
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL  
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION  
MAY NOT APPLY TO THE PURCHASER.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How State and Provincial law apply  
This limited warranty gives you specific legal rights, and  
you may also have other rights which vary from jurisdiction  
to jurisdiction. The provisions of the United Nations  
Convention on Contracts for the Sale of Goods shall not  
apply to this limited warranty or the sale of products  
covered by this limited warranty.  
1-888-DIMPLEX  
1-888-346-7539  
1367 Industrial Road  
Cambridge, Ontario  
Canada, N1R 7G8  
Approved for use in the United States and Canada  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Cobra Electronics Automobile Electronics CDR 900 User Manual
Cornelius Ice Maker 631814001 User Manual
Crown Boiler Boiler XBF SPD User Manual
Dacor Oven ECD227 User Manual
DigiPower Switch ePowerSwitch User Manual
Dimension One Spas Hot Tub 01510 1030E Rev A User Manual
Earthquake Sound Stereo Amplifier XJ 600R User Manual
Edelbrock Automobile Parts GM LT1 User Manual
Fujitsu Garage Door Opener D1521 User Manual
GE Washer Dryer WSM2420DCC User Manual