CAB & DAB
CAB10A, CAB10E, CAB10W, CAB15A, CAB15E & CAB15W
DAB10A, DAB10E, DAB10W, DAB15A, DAB15E & DAB15W
08/19023/9 (UK)
Issue 9
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014,
EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
Download from Www.Somanuals.com. All Manuals Search And Download.
CAB ‘E’ & DAB ‘E’
7
CAB ‘A’ & DAB ‘A’
CAB ‘W’ & DAB ‘W’
8
Y
X
Y
CAB 10
CAB 15
DAB 10
DAB 15
840
1260
800
240
240
300
300
X
1300
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimplex Compact Air Curtains
Models : CAB10E, CAB15E, CAB10W, CAB15W, CAB10A, & CAB15A
DAB10E, DAB15E, DAB10W, DAB15W, DAB10A, & DAB15A
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLYAND RETAINED FOR FUTURE REFERENCE
Fixing Positions
This appliance may be either wall-mounted or fixed to a ceiling -
see Fig. 3a & 3b for fixing positions and ‘Mounting’ sections
below for fixing details.
A minimum distance of 100mm is required from the top of the
appliance to ceiling - see ‘a’ in Fig. 1.
IMPORTANT SAFETY ADVICE
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille.
ENSURE THE APPLIANCE IS EARTHED.
Do not use this heater in areas where excessive dust exists.
The distance between the bottom of the appliance and the top of
a door should be kept to a minimum - see ‘b’ in Fig. 1.
This appliance should not be mounted less than 1.8m from the
floor.
This heater must not be located immediately above or below
a fixed socket outlet or connection box.
Always disconnect supply before working on the product.
This appliance should only be connected to the fixed wiring
of the premises by means of conduit.
Wall Mounting
Using the wall mounting bracket as a guide (see Fig. 2) mark off
hole positions on the wall (a minimum height of 2.0 metres is
required from the floor level to the bottom of the bracket). Position
the bracket such that the air outlet of the installed air curtain will
be as close to the top of the doorway as possible but will remain
unobstructed when installation is complete.
This product should be mounted safely to solid wall or ceiling
surfaces only.
This product must not be subjected to water spray or
immersion.
Solid brick or concrete block walls must be drilled and plugged
(using a spirit level as a guide - see ‘x’ in Fig. 2 - to ensure the
bracket is level) with rawlplug No. 8 size fibre inserts. The plug
must be located in the solid part of the wall and not just in the
plaster layer.
When fixing to ‘panel’ walls, the wall bracket should be attached
to the stud-work using No. 8 wood screws or by an alternative,
equally secure method of fixing.
Once the wall bracket has been fitted, the air curtain can be
clipped in place as shown in Fig. 3a.
Ceiling Mounting
Ensure the supply cables are of adequate current carrying
capacity and are protected by a suitable fuse.
If the appliance is mounted in a toilet or washroom, the
appliance should be mounted such that no part of it can be
touched by a person using a fixed bath or shower.
If the appliance is mounted in a toilet or washroom an
isolating switch must be provided outside the washroom
adjacent to the entrance door.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of appliance by a person responsible for their safety.
By using threaded inserts in the top panel of the air curtain,
attachment to a ceiling over the product can be achieved using
suitable M8 threaded steel rod or similar supports of sufficient
strength - see Fig. 3b.
WARNING: Isolate electrical supply to ALL modular linked
units when carrying out maintenance.
Electrical connection
All products are fitted with a microprocessor control. Electrical
power and control connections are made as shown in Fig. 6. A
suitable local isolating switch must be provided in the electrical
supply circuit with at least 3mm clearance on each pole.
In order to access the electrical connections, remove the outlet
grilles (‘x’ and ‘y’ in Fig. 4) by releasing the quick release fasteners
and hinging the mouldings as shown and then remove the
bottom panel (‘z’ in Fig. 4).
Models
Max
Installed
height
m
Weight
Heat
Electrical
Supply
Electrical
load
output
Model
kg
(per phase)
kW
AMBIENT / COLD STORE
CAB10A
CAB15A
DAB10A
DAB15A
n/a
n/a
n/a
n/a
220-240V ~1PN
220-240V ~1PN
220-240V ~1PN
220-240V ~1PN
0.3
0.5
1.5
2.3
15.5
21.5
21.5
27.5
3.0
3.0
4.0
4.0
For the Water heated and Ambient models only, the pressure
plate (‘w’ in Fig. 4) must also be removed.
All Electric Models - Having removed a ‘knock out’ in the top
panel, feed an appropriate supply cable (see ‘a’ in Fig. 6A) through
a suitable cable gland (not supplied) fitted in the top panel and
attach to the terminal block (see ‘b’ in Fig. 6A).
ELECTRICALLYHEATED
CAB10E
CAB15E
DAB10E
DAB15E
4.5 / 9.0
380-415V ~3PN
14
20
18
27
20.5
29
3.0
3.0
4.0
4.0
6.75 / 13.5 380-415V ~3PN
6.0 / 12.0
9.0 / 18.0
380-415V ~3PN
380-415V ~3PN
26.5
35
All Water heated and Ambient Models - Having removed
a ‘knock out’ in the top panel, feed an appropriate supply cable
(see ‘a’ in Fig. 6B) through a suitable cable gland (not supplied)
fitted in the top panel and attach to the PCB (see ‘b’ in Fig. 6B).
WATER HEATED (at 82/71 °C - LPHW)**
CAB10W
CAB15W
DAB10W
DAB15W
9.0
220-240V ~1PN
220-240V ~1PN
220-240V ~1PN
220-240V ~1PN
0.3
0.5
1.5
2.3
17.7
24.6
24.7
31.9
3.0
3.0
4.0
4.0
13.5
12.0
18.0
All Models - A suitable cable (CAT5 or equivalent) for a switch
panel (kit ref. - CABC5 for electrically heated models or CABC6
for water heated/ambient models) can be similarly introduced
through the top panel and plugged into the circuit board as shown
in Fig. 6A & 6B. If the unit is to be operated in conjunction with a
door switch, a normally open switch should be wired as per Fig.
7 & 8 as appropriate.
Electrical
The installation of this appliance should be carried out by a
competent electrician and be in accordance with the current IEE
wiring regulations.
Note: If using a door switch, an additional 2 core (low Voltage)
cable is required between the door switch and the air barriers.
Download from Www.Somanuals.com. All Manuals Search And Download.
If the unit is to be connected to a Building Energy Management
System, connections are made as per Fig. 7 & 8 as appropriate.
Ensure that the air curtain is securely fastened in position and
that the supply cables are firmly clamped before operating the
appliance.
To override the thermostat, first Isolate the supply to the heater.
Remove the connection on terminal ‘1’ of the thermostat and
reconnect it onto the piggy back connection on terminal ‘C’.
Door switch control (Electric models)
By including a door switch in the circuit (as per ‘D’ in Fig. 7) the air
curtain will respond to door openings as follows:
Water connection
(1) Door opening will energise the air curtain at the set
conditions (switch box settings).
Models designed for use in conjunction with a low pressure hot
water supply should be individually connected (in a parallel
circuit) to the flow and return pipe-work. Connections (see ‘a’ in
Fig. 5) are: ½” BSPT (CAB series) and ¾” BSPT (DAB series)
and isolation valves (see ‘b’ in Fig. 5) should be fitted as close
to the air curtain connection points as possible. For
commissioning, air bleed valves (see ‘c’ in Fig. 5) are fitted to
the coil, which can be accessed by removal of the bottom panel
and intake grille assembly - see Fig. 4. The drain (see ‘d’ in Fig.
5) can also be accessed when the intake grille assembly and
bottom panel are removed.
Maximum water supply conditions are 125ºC and 8 bar
(0.8MPa).
To aid installation, the water coil connections may be moved to
either side of the appliance. By removing the water coil and
appropriate knockouts the water coil can then be re-inserted
into the required orientation. This procedure should be carried
out before mounting the appliance.
(2) On door closure operation will continue at the set conditions
for a further 1 minute.
(3) Between 1 minute and 2 minutes from door closure, set
back operation, ½ heat (if heat selected) and ½ fan will
activate.
(4) Between 2 minutes and 3 minutes, the fan only (½ speed)
shut down cycle will be engaged.
(5) After 3 minutes, the air curtain will return to a dormant state
until the door is re-opened.
If the door re-opens during this 3 minute run on cycle, the
process will restart at (1).
Thermal Safety cut outs
The power supply to the heating elements will be interrupted if
one or a combination of the following abnormal events occur:
1.
2.
Air inlet or outlet grilles are obstructed.
Switch Panel Installation
Internal ventilation is impaired due to build up of dust
and fluff.
The backing box (standard double gang) should be rebated
into a suitable wall. The box should be fitted so that the switch
panel will be flush with the wall. Suitable conduit should be
used where applicable to carry the cable between the heater
and the switch. A CAT5 LAN cable with straight through
connections should be used to connect the switch panel to the
appliance PCB.
3.
Blower unit stalls.
To reset the thermal safety cut-outs, access reset buttons as
shown in Fig. 9. Before re-setting the reason for activation must
be determined and corrective action taken.
Low pressure hot water heated / Ambient (fan
only) variants
Warning: Ensure cable is secure and the cable path does not
come into contact with heater element or other moving parts.
Operation using switch box - CABC6
Switch on electrical supply to the air curtain. Rotate the switch to
the desired heat setting. Settings available are;
Test all switch settings once installation is complete.
OFF - Low Fan - High Fan
Electrically heated variants
The rocker (auto / manual) switch allows for manual over-ride of
a door switch if fitted. Manual allows the appliance to run at the
desire setting, while Auto provides an energy saving feature by
shutting down the appliance while the door is closed.
The unit should always be switched OFF using the switch box
control, and not by mains power supply interruption.
When first turned on the control will run through a system check.
The selected settings will be reached and maintained after a 30
second period.
Operation using switch box - CABC5
Switch on electrical supply to the air curtain. Rotate the switch
to the desired heat setting. Settings available are;
OFF - Low Fan - Low Fan with Low Heat &
High Fan - High Fan with Low Heat - High Fan with Full Heat
The rocker (auto / manual) switch allows for manual over-ride of
a door switch if fitted. Manual allows the appliance to run at the
desire setting, while Auto provides an energy saving feature by
shutting down the appliance while the door is closed.
The unit should always be switched OFF using the switch box
control, and not by mains power supply interruption.
When the unit is switched off (via the switch box) the fan will run
on for 1 minute without heat to discharge any residual energy
from the heating elements.
Thermostatic control (optional)
1) A thermostatic regulation valve with a remote sensing bulb
(not supplied) can be positioned in the supply water pipe-work to
regulate the heat output.
2) An electrical 3-Port Solenoid Valve can also be connected into
the system. Please contact your service agent using the contact
details for more details.
When first turned on the control will run through a system check.
The selected settings will be reached and maintained after a 30
second period.
Door switch control (Water heated & Ambient models)
By including a door switch in the circuit (as per ‘D’ in Fig. 8) the air
curtain will respond to door openings as follows:
Thermostatic control
A capillary type thermostat is factory fitted within the unit, as per
‘C’ in Fig. 7, giving a selection scale of 0-40ºC. When the
thermostat operates, the power output will reduce depending
on the switch setting.
(1) Door opening will energise the air curtain at the set
conditions (switch box settings).
(2) On door closure operation will continue at the set conditions
for a further 1 minute.
(3) Between 1 minute and 2 minutes from door closure ½ fan
set back operation will activate.
- Fan only - No effect
- Half Heat - Heater will reduce to Fan only
-Full Heat - Heater will reduce to Half Heat
Download from Www.Somanuals.com. All Manuals Search And Download.
(4) After 2 minutes, the air curtain will return to a dormant state
until the door is re-opened. If the door re-opens during this 2
minute run on cycle, the process will re-start at (1).
Wiring Diagrams
CAB & DAB ‘E’ - Electric models - see Fig. 7
CAB & DAB ‘W’/ ‘A’- Water heated & Ambient models - see Fig. 8
C -
D -
E -
F -
-
Thermostat
Door Switch (Optional)
Thermal Safety Cut-out Circuit
Elements
BMS Switches (Optional)(S,S1,S2)
Motor
M -
Remote (BMS / BEMS) Operation
Connection to Building Energy Management Control Systems
(BEMS) is possible so that remote control of the air curtain can be
carried out in conjunction with other equipment. Please refer to
the table in Fig. 7 & 8 to make the appropriate connections to the
PCB.
Modular Connection
Refer to instructions provided with the modular linking kit.
Recessed Installation
Refer to instructions provided with the recess installation kit.
De-rating the unit to operate at 1/2 heat setting
Please contact your sales or service agent using the contact details
provided.
Operation on a Single Phase Supply
Please contact your sales or service agent using the contact details
provided.
Download from Www.Somanuals.com. All Manuals Search And Download.
Recycling
For electrical products sold within the European Community.
At the end of the electrical products useful life it should
not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local
Authority or retailer for recycling advice in your country.
Cleaning
WARNING: DISCONNECT SUPPLY before carrying out
maintenance.
External appearance can be maintained by wiping occasionally
with a damp cloth ; for stain removal, a weak soap solution can
be applied with a cloth and the surface wiped dry. Care must be
taken to avoid any moisture ingress into the product.
After Sales Service
Your product is guaranteed for three years from the date of
purchase.
Within this period, we undertake to repair or exchange this product
free of charge provided it has been installed and operated in
accordance with these instructions.
Your rights under this guarantee are additional to your
statutory rights, which in turn are not affected by this
guarantee.
Should you require after sales information or assistance with
find our self help guide by clicking on “After Sales” or ring our
helpdesk on 0845 600 5111 (UK) or 01 842 4833 (R.O.I.) .
Spare parts are also available on the website
Please retain your receipt as proof of purchase.
Download from Www.Somanuals.com. All Manuals Search And Download.
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC)
EN55014, EN60555-2 and EN60555-3. These cover the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
Dimplex UK Ltd.
Millbrook House
Grange Drive
Hedge End
Southampton
Tel.
01 8424833
Republic of Ireland
Hampshire. SO30 2DF
[c] Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex UK Limited.
Download from Www.Somanuals.com. All Manuals Search And Download.
|