1. Safety
General:
!
Before using this unit, read this manual completely and gather all information on
the unit. Make sure that you understand it fully. Check that your application does
not exceed the safe operating specifications for this unit.
Before installation, maintenance or modification work:
Prevent damage to internal electronics from electrostatic discharges (ESD)
!
by discharging your body to a grounding point (e.g. use of wrist strap).
Prevent access to hazardous voltages by disconnecting the unit from AC/DC
mains supply and all other electrical connections.
Installation:
!
This unit should only be installed by qualified personnel.
This unit should only be installed in a “restricted access area”, for example
a lockable cabinet where access is restricted to service personnel only.
This unit is intended for permanent connection to the AC/DC mains supply.
The power supply wiring must be sufficiently fused, and if necessary it must be
possible to disconnect manually from the AC/DC mains supply. Ensure compliance
to national installation regulations.
Unit with the rated voltage exceeding 42.4V peak or 60VDC, is defined as class I
equipment with a protective earthing conductor terminal.
Unit with the rated voltage up to 42.4V peak or 60VDC, is defined as class III
equipment and shall be separated from hazardous voltage by double or reinforced
insulation.
This unit uses convection cooling.To avoid obstructing the air flow around the
unit, follow the spacing recommendations (see under chapter Installation).
2. Approvals
Conformity with the Directive 89/339/EEC (Electromagnetic compatibility)
has been assessed by application of standards EN 61000-6-2 (industrial immunity)
and EN 61000-6-4 (industrial emission).
6609-2221
3
Download from Www.Somanuals.com. All Manuals Search And Download.
2.1 Declaration of Conformity
Westermo Teleindustri AB
Declaration of conformity
The Westermo Teleindustri AB company declares that the listed products conforms to the Council
Directive 89/336/EEC, related to Electro Magnetic Compability.
Industrial Ethernet adapter
ED-10LV
ED-10LV TCP
ED-10LV Custom
ED-20LV
Type of equipment:
Model:
3609-0001
3609-0010
3609-0020
3609-1001
Standards:
EMC Immunity: EN 50082-1:1997
EN 50082-2:1995
EN 61000-6-2:1999
EMC Emission: EN 50081-1:1992
EN 50081-2:1993
Technical Manager
April 2002
Org.nr/
Säte/
Postadress/Postal address
Tel.
Telefax
Postgiro
Bankgiro
Corp. identity number
Registered office
S-640 40 Stora Sundby
016 - 42 80 00
016 – 42 80 01
52 72 79-4
5671-5550
556361-2604
Eskilstuna
Sweden
Int +46 16 42 80 00 Int +46 16 42 80 01
4
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Introduction
The ED-20 is an industrialised DIN Rail mounted, serial to Ethernet Router.The device
will allow access to a remote Ethernet network via a Westermo communication product.
The device is easily set-up using the ED-Tool for ED-20 configuration program via
TELNET or serial connection.
Standard PPP dial-up networking tools can be used from Microsoft Windows 9x, ME, NT,
2000 or XP, Or another ED-20 to connect to the device.Any other platform supporting
the PPP protocol could equally be used.
Passwords are provided to increase the remote site security. Once connected to the
remote network all TCP/IP, FTP,TELNET and UDP protocol types can be used.
Connection to the ED-20 is via 10Base-T on the Ethernet and RS-232 on the serial side.
The serial port supports speeds up to 115 k/bit.
Total galvanic isolation ensures that the data communication will not be effected by
ground loops or transfer electrical noise between communications ports.The high EMC
specification, like all other Westermo production ensures reliability of operation in the
harshest of site conditions.
PSTN
TD-32B
ED-20
TD-33
ED-20
PPP
ROUTER
Serial Interfa
ce
TCP/IP
Ethernet
6609-2221
5
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Specification
Network Interface
Data rate
10BASE-T. IEEE std 802.3, 2000 Edition.
10 Mbit/s, half duplex.
Mechanical
RJ-45 Modular Jack (ISO/IEC 8877:1992),
Unshielded or shielded (UTP/STP).
Serial Interface 1 (CH 1) RS-232
Data rate
300–115 200 bit/s Full, half duplex or simplex.
Data format
Control signals
Mechanical
8 Data Bits, No Parity Bit,1 Stop Bit
RTS, CTS, DSR, DCD, DTR
9-pin female D-sub, DCE.
Serial Interface 2 (CH 2) RS-232
Data rate
19 200 bit/s
Data format
Control signals
Mechanical
8 Data Bits, No Parity Bit, 1 Stop Bit
–
9-pin female D-sub, DCE.
Power Interface
Rated voltage
Rated current
Rated frequency
Mechanical
10–60VDC polarity independent. / 12–30VAC
350 mA, max @ 10VDC input.
48–62 Hz
2
Screw Terminal. 0,2–2,5 mm , 24-12 AWG
Isolation
Functional and safety
Power Interface to
all other Interfaces*
Network Interface
to serial interface
4.2 kV DC,3 kV RMS @50–60 Hz. EN 60950:2000
2.1 kV DC, 1.5 kV RMS @ 50–60 Hz.Applied for 60 sec
as specified in 5.3.2 of EN 60950:2000.
6
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
Transient Protection
Power Interface 4 kV, EN 61 000-4-5:1995 Class 4
2 kV, EN 61 000-4-5:1995 Class 3
0.5 kV, EN 61 000-4-5:1995 Class 1
Network Interface
Serial Interface
Application
Throughput (maximum)
Network protocols
Serial/Network conversion
115 kbit/s (1.44 MB data)
TCP, IP,ARP, ICMP,Telnet
Configuration
Remotely over network or locally at serial interface.
Windows based PC-programme.
Indicators (LED)
TD, RD, CTS, RTS, PWR,TD, RD, CONFIG, NET
Climatic environment
Temperature, operating
5–50°C
Relative humidity, operating
Dimension (WxHxD)
Weight
5–95% REL non condensing
55 x 100 x 128 mm
0.35 kg
Mounting
Approvals
35 mm DIN-rail
CE
* Power to network interface,1.5 kV RMS @50–60 Hz functional isolation.
6609-2221
7
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
6. Installation
6.1 Mounting /Removal
Before mounting or removing the unit:
!
Prevent damage to internal electronics from electrostatic discharges (ESD)
by discharging your body to a grounding point (e.g. use of wrist strap).
Prevent access to hazardous voltages by disconnecting the unit from AC/DC
mains supply and all other electrical connections.
Mounting
This unit should be mounted on 35 mm DIN-rail which is
horizontally mounted on a wall or cabinet backplate.
This unit uses convection cooling. To avoid obstructing the air
flow around the unit, use the following spacing rules.
Minimum spacing 25 mm (1.0 inch) above/below and 10 mm
(0.4 inches) left/right the unit.
Snap on mounting, see figure.
Min
10 mm
Removal
Press down the black support at the back of the unit
using a screwdriver, see figure.
8
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
6.2 Connections
Cannel 2:
RS-232 connection
Cannel 1:
RS-232 connection
ED-20
PPP R
OUTER
Serial Interface
Ethernet 10Base-T
connection
Power
Ethernet 10Base-T Connection (RJ-45 connector),
straight function MDI (no crossover)
8
7
6
5
4
3
2
1
Contact
Signal Name
TD+
Direction** Description
1
2
3
4
5
6
7
8
Out
Out
In
Transmitted Data
TD–
Transmitted Data
RD+
Received Data
NC
NC
RD–
In
Received Data
NC
NC
**
Direction relative ED-20
NC Not connected
CAT 5 cable is recomended.
Unshielded (UTP) or shielded (STP) cables might be used.
6609-2221
9
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
4
5
6
7
8
9
CH1: RS-232 Connections, DCE
Pin Signal Name*
Direction** Description
Number Description
V.24
109
RS-232C
CF
1
2
3
4
5
6
7
8
9
DCD
Out
Out
In
Data Carrier Detect
Received Data
RD
104
103
108.2
102
107
105
106
125
BB
BA
CD
AB
CC
CA
CB
CE
TD
Transmitted Data
Data Terminal Ready
Signal Ground
DTR
SG
In
In/Out
Out
In
DSR
RTS
CTS
RI
Data Set Ready
Request to Send
Clear to Send
Out
–
Ring Indicator, NC
*
**
Functionality might differ from standard
Direction relative ED-20
NC Not connected
1
2
3
4
5
6
7
8
9
CH2: RS-232 Connections, DCE
Pin
Signal Name*
Direction** Description
Number Description
V.24
109
RS-232C
CF
1
2
3
4
5
6
7
8
9
DCD
RD
–
Out
In
Data Carrier Detect, NC
Received Data
104
103
108.2
102
107
105
106
125
BB
BA
CD
AB
CC
CA
CB
CE
TD
Transmitted Data
DTR
SG
–
DataTerminal Ready, NC
Signal Ground
In/Out
–
DSR
RTS
CTS
RI
Data Set Ready, NC
Request to Send, NU
Clear to Send, NU
Ring Indicator, NC
In
Out
–
*
**
Functionality might differ from standard
Direction relative ED-20
NC Not connected
NU Not used
10
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
6.3 LED Indicators
From left to right.
CH1:TD
LED off
LED on
Transmitted Data (incoming serial data):
• RS-232 TD =1, Mark (<–3V).
• RS-232 TD =0, Space (>3V).
CH1: RD
LED off
Received Data (outgoing serial data):
• RS-232 RD =1, Mark (<–3V).
• RS-232 RD =0, Space (>3V).
LED on
CH1: RTS
LED off
Request To Send:
• RS-232 RTS =Off (<–3V).
• RS-232 RTS =On (>3V).
LED on
CH1: CTS
LED off
Clear To Send:
• RS-232 CTS =Off (<–3V).
• RS-232 CTS =On (>3V).
LED on
PWR
Power:
LED off
LED on
• No internal power, (external power not connected).
• Power OK.
CH2:TD
LED off
LED on
Transmitted Data (incoming serial data):
• RS-232 TD =1, Mark (<–3V).
• RS-232 TD =0, Space (>3V).
CH2: RD
LED off
Received Data (outgoing serial data):
• RS-232 RD =1, Mark (<–3V).
• RS-232 RD =0, Space (>3V).
LED on
CONFIG
LED on
ED-20 working mode:
• Configuration mode.
LED off
• Application mode,
(or during start up of configuration mode).
NET
Indication of network status:
• Link Test failed (no network).
• Link Test passed.
LED off
LED on
LED flashing
• Data on Network (traffic).
6609-2221
11
Download from Www.Somanuals.com. All Manuals Search And Download.
6.4 DIP Switch Settings
DIP-switches are accessible under the lid on top of the unit.
Warning! Prevent damage to internal electronics from electrostatic discharges
!
(ESD)
by discharging your body to a grounding point (e.g. use of wrist
strap), before the lid on top of the modem is removed.
Warning! Do not open connected equipment.
!
Prevent access to hazardous voltages by disconnecting the unit from
AC/DC mains supply and all other electrical connections.
NOTE
The change of DIP switch settings are valid only after a power on.
S2:1-8
Channel 2
IC 2
S1:1-8
Channel 1
The DIP Swiches is not used in this product, leave as it is.
Factory settings
ON
ON
Channel 1
S1
S2
Channel 2
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
12
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
6.4.1 MAC address
The MAC address of the unit can be found on the product label “00 30 56 F” + last 5
digits on IC2 see figure in section 6.4 Switch settings on page 12. Example: Label on IC2
“SC12 RTOS 0092C2” this will give the unit MAC address “00 30 56 F0 92 C2”
The MAC address can also be find out with the DOS command “ARP –a”. (Perform the
“PING” command with the ED-10 local IP address before the ARP command.)
6.5 Installation of ED-Tool for ED-20
System Requirements:
To install and run the ED-Tool for ED-20 program following requirements are needed.
Minimum:
• 386, 486 or Pentium‚ Processor-based personal computer
• Microsoft‚ Windows‚ 95/98/Me, NT 3.51/4.0,
2000 or XP‚ Or compatible OS.
• 16 MB of RAM for Windows 95/98/Me systems
• 24 MB of RAM for Windows NT systems
• 32 MB of RAM for Windows 2000/XP systems
• CD-ROM drive
• 8 MB of space on hard drive
• Serial and/or ethernet network connections
• Internet Explorer 5.0 or higher
Recommended:
• Pentium processor-based personal computer
• 32 MB of RAM
Installation:
To install ED-Tool for ED-20
• Insert the ED-Tool for ED-20 CD-ROM into the CD-ROM drive.
• Locate the Setup.exe file on the ED-Tool CD-ROM.
• Start the Setup.exe and follow the instructions.
6609-2221
13
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Functional description
The ED-20 can be in either configuration mode or in application mode. Normally the
ED-20 is in application mode, where the serial-to-network data transfer is enabled and all
configuration settings are readable.
Change of configuration parameters are done in ED-20 configuration mode. Configurable
parameters are listed in chapter 6.3.
7.1 Application mode
In application mode the ED-20 transfers data between the serial interface (CH1) and the
network interface (10BaseT).At the network interface data is transferred using the
TCP/IP protocol suit.At the serial interface data is transferred using PPP.
7.1.1 About PPP
PPP (the Point to Point Protocol) is a mechanism for creating and running TCP/IP over
a serial link – a direct serial connection or a link made using one of following:
Westermo analogue PSTN-, Leased-line-, ISDN-, GSM-, Radio-, Fibre- or Short-haul
modem.
Other computers can connect via the ED-20 and communicate over the PPP link using
FTP,Telnet,Web, etc. in the same manner as with an Ethernet TCP/IP link. One major
difference between a PPP and an Ethernet connection is of course the speed.A standard
Ethernet connection operates at 10 Mbs maximum theoretical throughput, whereas an
analogue modem operates at speeds up to 56 kbps.
PPP is strictly a peer to peer protocol; there is no difference between the machine that
dials in and the machine that is dialed into. However, it is still useful to think in terms of
servers and clients.When you dial into a site to establish a PPP connection, you are a
considered the client.The machine to which you connect is considered the server.
Authentication is provided with the protocols PAP and CHAP.
7.1.2 Network interfaces
ED-20 has two network interfaces, Ethernet and PPP, so the unit can forward IP-packets
between these interfaces.
7.1.2.1 Ethernet connection
This interface is a part of the local network and the ‘Local IP Address’* and ‘Subnet Mask’
must be set to the right ‘Network ID’
* The IP address must be compliant to the attached network.
Ask the network administrator when in doubt.
14
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
7.1.2.2 PPP connection
The PPP connection can be established over PSTN, Leased Line or private lines.
ED-20 can act as a PPP Server, PPP Client or both.These functions is set on the ‘Modem
settings’ tab in ED-Tool for ED-20. See application example on page 30.
Connections can be established in several ways depending on the application:
• Standard PPP dial-up networking tool.
• ‘Connect’ command on CH2: or via TELNET
• Using the ‘Brouter’ function.
7.1.2.3 Brouter function
The Brouter function will establish a dial-up connection when valid outbound IP address
(Defined on the tab ‘Brouter Settings’ in ED-Tool for Ed-20) is sent to the ED-20.
See application example on page 31.
The connection will be open until one of following is true:
• There is no traffic during and the ‘Idle Time’ parameter is set to a value greater
than zero.
e.g. Idle Time is set to 600s and there is no traffic sent to the ED-20
for more than 10 minutes.
• ‘Close’ command on CH2: or via TELNET
Note! It may be wise to use the Firewall function while the Brouter function being used
to reduce the traffic over the PPP link.
7.1.2.4 Firewall function
The Firewall function can be set-up to allow or block certain IP Addresses through the
ED-20. See application example on page 31.
7.2 Configuration mode
Local or remote configuration is managed by ED-Tool for ED-20.
ED-Tool for ED-20 is a Windows based set-up programme which provides easy
configuration.
Configuration is possible locally by using serial connection and remote using network
(telnet) connection. Configuration mode will be entered automatically by ED-Tool for
ED-20. ’Config ’ LED will lit when ED-20 is in configuration mode. (The unit is not in
configuration mode until the ‘Write config’ button been pushed.)
The unit will be in configuration mode until a reboot is made.
First time configure: ED-20 is shipped with IP-address 169.254.100.100.
Please make sure that 169.254.100.100 is compliant to your network, before ED-20 is
connected. Otherwise use serial interface to locally set a valid IP address compliant with
the network in use and not chosen arbitrarily, ask your network administrator when in
doubt.
6609-2221
15
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Configuration
Before read, write or reboot can be made, Select type of connection:
• Network
• Serial com port must be selected from menu ‘Tools – Serial COM Port’
8.1 Configuration by ED-Tool for ED-20
This section describes the configuration of the ED-20 with the software ED-Tool
for ED-20.
Program Start:
To start ED-Tool for ED-20
• Locate ED-Tool under Program on the Start-Menu.
• Click on the ED-Tool for ED-20 icon
When the ED-Tool for ED-20 has been successful opened the user is presented with an
empty configuration screen.The user can now get an existing configuration by reading
the configuration from an ED-20, create a new file from default values or by opening a
stored configuration file.
After all the parameters are set the user can write the configuration to the ED-20.
Typical configuration procedures:
• Read configuration from an ED-20
• Change some parameters
• Write configuration to the ED-20
• Reboot
• Done
or
• Read configuration from a file
• (Change some parameters)
• Write configuration to the ED-20
• Reboot
• Done
or
• Set parameters
• Write configuration to ED-20
• Reboot
• Done
or
• Set parameters
• Save configuration to a file
• Done
16
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
8.1.1 ED-Tool for ED-20 commands
This section describes the ED-Tool for ED-20 commands.
The commands are described by there use.
Details about allowed values and default values is described is section 6.2.
1
2
57600
3
RTS/CTS
4
5
6
8.1.1.1 General commands
1
Selects type of connection, Serial or over the Network.
If ‘Serial’ is selected, use the “Tools menu – Serial COM port” to
select which of COM1:, COM2:, COM3:, or COM4: your serial
cable is connected to.
2 Read Config
3 Write Config
Reads configuration from the ED-20.
Writes configuration to the ED-20.
Note! ED-20 must be rebooted before any new configuration
is activated.
4 Reboot
Reboots the ED-20.
8.1.1.2 Serial Interface – Channel 1 specific commands
5 Data Rate
6 Flow Control
Selects Data Rate for serial communication, ED-20 – Modem.
Selects if flow control is used or not.
Note! All interconnecting wires are required between the ED-20
and the attached modem.
6609-2221
17
Download from Www.Somanuals.com. All Manuals Search And Download.
PSTN
AT&F&DOSO
ATH
OK
3
DIAL IN/OUT
NO
OK
3
NO
+++
2
1
1
1
2
3
4
5
6
7
ATDS=0
RING
ATA
0
600
CONNECT
60
1
8.1.1.3 Modem Settings
General
1 Modem
Connection
Select Type of connection, PSTN or LL.
• Use PSTN for dial-up connections, e.g. Phone modem, GSM
modem or ISDN adapter.
• Use LL for fixed connections, e.g. LeasedLine-, Radio-, Fibre-
or any Short-haul- modem.
2 Dial IN/OUT
Select if the ED-20 shall act as a PPP Server, PPP Client or both.
When the unit is set to be a server, it will answer incoming calls.
Select if the ED-20 shall initiate a connection at power on
with the Modem Connect (Dial Out) command.
Select if the ED-20 shall disconnect the PPP link at modem DCD
loss.
3 Connect at
PWR On
4 DCD Control*
Note! All interconnecting wires are required between the ED-20
and the attached modem.
5 Escape
Sequence
6 Escape Delay
Set the modem escape sequence wich switches the modem into
command mode. Not used for Leased Line mode. Usually ‘+++’.
Set the delay time in seconds after the escape sequence before
any other command.
7 Idle Time
Set the idle time in seconds, after which the PPP server closes the
connection if no data being sent.
18
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
Modem AT-Commands
Refer to the user guide or installation manual to the attached modem.
AT&F&DOSO
ATH
OK
3
16
17
18
19
20
21
22
1
2
3
4
5
6
7
8
OK
3
1
1
ATDS=0
RING
ATA
0
CONNECT
60
1
Modem Init
8 Command
9 Answer
Set the modem init string, max string length:25 characters.
Set the expected answer from the modem on the command
string. Note! Modem result codes must be enabled.
Set the timeout in seconds for how long the ED-20 shall wait
for the answer string.
10 Timeout
11 Retries
Set the number of retries before the modem init fails.
Modem Hangup
12 Command
13 Answer
Set the modem hangup string, max string length:25 characters.
Set the expected answer from the modem on the command
string. Note! Modem result codes must be enabled.
Set the timeout in seconds for how long the ED-20 shall wait for
the answer string.
14 Timeout
15 Retries
Set the number of retries before the modem hangup fails.
Modem Connect (Dial Out)
16 Command
17 Answer
Set the modem connect string, max string length:25 characters.
Set the expected answer from the modem on the command.
string. Note! Modem result codes must be enabled.
Set the timeout in seconds for how long the ED-20 shall wait for
the answer string.
18 Timeout
19 Retries
Set the number of retries before the modem connect fails.
Modem Connect (Dial In)
20 Command
21 Answer
22 Timeout
Set the modem connect string, max string length:25 characters.
Set the expected answer from the modem on the command.
Set the timeout in seconds for how long the ED-20 shall wait for
the answer string.
6609-2221
19
Download from Www.Somanuals.com. All Manuals Search And Download.
ed20
NONE
****
1
2
3
169.254.100.100
255.255.255. 0
169.254.200.100
169.254.200.101
255.255.255. 0
4
5
6
7
8
8.1.1.4 Network Settings
Login
1 Authentication
2 Username
Select if authentication shall be used or not.
Set the login username.
This is also used for Telnet sessions (Network configuration).
3 Password
Set the login password
This is also used for Telnet sessions (Network configuration).
PPP Network Interface*
4 Local IP
Set the Server IP address.
5 Remote Address Set the Client IP address.
6 Subnet Mask
Set the Subnet mask.
Ethernet Interface*
7 Local IP Address Set the Local IP address i.e. the address of the ED-20.
8 Subnet Mask Set the Subnet mask.
* The IP address must be compliant to the attached network.
Ask the network administrator when in doubt.
20
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
.
.
.
1
2
3
4
5
6
8.1.1.5 Brouter Settings
Brouter Mode
1 Off / On
Disables or enables the Brouter mode.
See 8.2.4
Brouter Settings
2 IP Address
3 Connect
Message
Set the target IP address that shall initiate a connection.
Set the Connect message that shall be sent to the attached
modem. E.g.ATDnnnnnn
4 Add >>
Adds the values IP Address and Connect message to the
brouter entry list
5 Remove …
6
Remove marked entry from entry list.
Brouter Entry List
Displays the Brouter entry’s: IP Address, Connect message.
Up to 32 entry’s can be added.
• To Add an entry: Fill in the field IP Address and the field Connect message, Press add.
• To Edit an entry: Double click the entry that shall be edited, Edit the values in the fields
to the left, Press add.
• To Remove an entry: Click the entry that shall be removed, Press remove.
6609-2221
21
Download from Www.Somanuals.com. All Manuals Search And Download.
.
.
.
1
2
3
4
5
8.1.1.6 Firewall Settings
Firewall Mode
1 Off / Pass / Block Disables or enables the Firewall mode and selects if the firewall
shall work in Block or Pass mode. See 8.2.5
Firewall Settings
2 IP Address
Set the source and destination IP addresses that shall be allowed
to pass through the ED-20, or set the source or destination IP
addresses that shall be blocked from passing through the ED-20.
Adds the values IP Address and Connect message to the
Firewall entry list.
3 Add>>
4 Remove …
Remove marked entry from entry list.
5
Firewall Entry List.
Displays the Firewall entry’s: IP Address.
Up to 32 entry’s can be added.
22
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
8.2 Configurable parameters
8.2.1 Serial interface
Communication
Data Rate
The data rate can be set from 1 200 bit/s to 115.2 kbit/s.
Allowed values:
1 200, 2 400, 4 800, 7 200, 9 600, 14 400, 16 000, 19 200, 38 400, 56 000, 57 600
and 115 200 bit/s.
Default: 57 600 bit/s.
Flow Control
Flow control can be chosen between none or RTS/CTS.
If the RTS/CTS being used then the cable must have all interconnecting wires between
the ED-20 and the modem connected and the modem shall have the flow control
enabled.
Allowed values: None, RTS/CTS
Default: RTS/CTS.
8.2.2 Modem settings
General
The general settings is used to set the fundamental modes of the ED-20.
Modem Connection
Type of modem connection can be selected between PSTN (Public Switched Telephone
Network) and LL (Leased Line).
PSTN shall be used for dial-up/dial-in connections with PSTN, ISDN or GSM modem.
LL shall be used in fixed connections, e.g. short-haul-, fibre-, LL-, or Radio-modem.
In LL mode the unit will not use any modem AT-commands, Modem escape sequence,
AT-commands and the Brouter function will be disabled.The modem will be handled as
a transparent connection.
Allowed values: LL, PSTN
Default: PSTN.
6609-2221
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Dial IN/OUT
Select the operating mode of the ED-20.
-Dial IN,
The unit will act as an PPP Server and only accept incoming calls.
Modem Connect (Dial OUT) and the Brouter function will be disabled.
-Dial IN/OUT,
The unit will act both as an PPP Server and an PPP Client.
When an incoming call is detected then the PPP Client is disabled.
–Dial OUT,
The unit will act as an PPP Client and not accept incoming calls.
Modem Connect (Dial IN) and the function Connect at PWR on will be disabled.
Allowed values: Dial IN, Dial IN/OUT, Dial OUT
Default: Dial IN/OUT
Connect at PWR on
Selects if the ED-20 shall establish a connection at Power on or not.
In PSTN mode the ED-20 will dial up using the command string defined in Modem
Connect (Dial OUT) and when the modem link is ready, Establish the PPP link.
In LL Mode the ED-20 will establish the PPP link.
This function is disabled in Dial IN mode.
Allowed values: NO,YES
Default: NO
DCD Control
When the signal DCD is lost the ED-20 will close the PPP link and when PSTN mode
is selected the AT commands for Modem hangup and Modem init will be sent to the
modem.
This function requires a special cable.
Allowed values: NO,YES
Default: NO
TD-XX
With 9-pos. female
DCE connection
ED-20
With 9-pos. female
DCE connection
TD-XX
With 25-pos. female
DCE connection
ED-20
With 9-pos. female
DCE connection
2
3
8
7
4
5
1
3
2
7
8
6
5
4
3
2
3
2
7
8
6
5
4
5
4
20
7
8
9-pos. female
9-pos. female
25-pos. female
9-pos. female
24
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
Escape Sequence
When communication is established with another modem it is still possible to reach the
command mode by sending an escape sequence to the modem.
Note! Refer to the user guide or installation manual to the attached modem.
Default: +++
Escape Delay
Define the delay time in seconds after the escape sequence been sent until the next
AT-command will be sent.
Allowed values, 1 to 9999
If this value is set to zero, the unit will do nothing but wait!
Default: 2 (seconds)
Idle Time
If no data is being sent over the PPP link the ED-20 will close the connection.
Define the time in seconds.
Allowed values, 0, 1 to 9999
Default: 0 (function disabled)
Modem AT-Commands
Commands used in PSTN mode for controlling the behaviour of the attached modem.
Note! Refer to the user guide or installation manual to the attached modem.
Modem Init
Command
Init string that will be sent to the modem.
Default:AT&F&D0S0=0&K3+MS=V34;&W
Answer
Expected answer from the modem on the sent command.
Default: OK
Timeout
Define the time in seconds between the sent command and the expected answer before
the command have failed.
Allowed values: 0 to 9999
Default: 3
Retries
Define the number of retries in case if a failed command.
Allowed values: 0 to 9999
Default: 1
6609-2221
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Modem Hangup
Command
Hangup string that will be sent to the modem.
Default:ATH
Answer
Expected answer from the modem on the sent command.
Default: OK
Timeout
Define the time in seconds between the sent command and the expected answer before
the command have failed.
Allowed values: 0 to 9999
Default: 3
Retries
Define the number of retries in case if a failed command.
Allowed values: 0 to 9999
Default: 1
Modem Connect (Dial Out)
Command
Dial out string that will be sent to the modem.
Default:ATDS=0 (dials the stored number in location 0, stored with AT&Z command)
Answer
Expected answer from the modem on the sent command.
Default: CONNECT
Timeout
Define the time in seconds between the sent command and the expected answer before
the command have failed.
Allowed values: 0 to 9999
Default: 60
Retries
Define the number of retries in case if a failed command.
Allowed values: 0 to 9999
Default: 1
Modem Connect (Dial In)
Command
Dial in string that will be sent from the modem on an incoming call.
Default: RING
26
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
Answer
Command that will answer the incoming call.
Default:ATA
Timeout
Define the time in seconds, For how long time the ED-20 will accept incoming calls from
power-up. Normally not used, leave as is.
Allowed values: 0-9999
Default: 0
8.2.3 Network Settings
Login
The login username and password is used on the dial-in connection and when the ED-20
is configured with ED-Tool for ED-20 over a network connection.
Authentication
Select if authentication shall be used over the PPP link or not.
Authentication can be used with either the PAP (Password Authentication Protocol) or
CHAP protocols (Challenge Handshake Authentication Protocol)
If a invalid Username or password is entered the ED-20 will disconnect the PPP link and
cause the modem to disconnect.
Allowed values: NONE, PAP, CHAP
Default: NONE
Username
Allowed string length: 1 – 19 characters.
Allowed characters:‘0’ to ‘9’,‘a’ to ‘z’ lower case.
Default: ed20
Password
Allowed string length: 1 – 19 characters.
Allowed characters:‘0’ to ‘9’,‘a’ to ‘z’ lower case.
Default: ed20
6609-2221
27
Download from Www.Somanuals.com. All Manuals Search And Download.
PPP Network Interface
These values is used when the ED-20 is in Server mode.
The server will provide the IP addresses for the PPP link.
Note!When connecting to a private remote network via the ED-20 using Windows net-
work connection wizard,Always Obtain an IP address automatically
Local IP*
When the ED-20 is in server mode, this will be the Servers IP address on the PPP link
Note!The Network ID must be different than the Network ID on the remote network
and the Network ID locally.
Allowed values: Should be in decimal dotted notation in one off the following ranges:
1.0.0.0
126.0.0.0
128.1.0.0
192.0.1.0
191.255.0.0
223.255.255.0
Default: 169.254.200.100
Remote address*
When the ED-20 is in server mode, this will be the Clients IP address on the PPP link
Allowed values: Should be in decimal dotted notation And have the same Network ID
as Local IP and different then Local IP
Default: 169.254.200.101
Subnet Mask*
Set a valid subnet mask in decimal dotted notation.
Default: 255.255.255.0
Ethernet Interface
Local IP Address*
This is the address of the router and this address shall be used as default gateway in the
units that will use the ED-20 as a gateway.
Set the local IP address in the rage of the Network ID.
Note! The Network ID must be different than the Network ID on the PPP link
and the Network ID on the other network.
Allowed values: Should be in decimal dotted notation in one off the following ranges:
1.0.0.0
126.0.0.0
128.1.0.0
192.0.1.0
191.255.0.0
223.255.255.0
Default: 169.254.100.100
Subnet Mask*
Set a valid subnet mask in decimal dotted notation.
Default: 255.255.255.0
* The IP address must be compliant to the attached network.
Ask the network administrator when in doubt.
28
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
8.2.4 Brouter settings
The brouter function will initiate outgoing connections.
This function is only available in PSTN + Dial Out mode
(Refer to section 8.2.2 – General – Modem settings and Dial IN/OUT.)
When a IP packet sent to the ED-20 have a IP Address that match a IP Address in the
entry list, the ED-20 will send the connect message to the attached modem.This will
result in an connection to another location and establishment of a PPP link.
Note! Since the ED-20 and the attached modems need some time to establish a modem
connection and a PPP link,The IP packets sent before the PPP link is ready may be
lost depending of the application used.
Brouter Mode
Enable or disable the brouter function with the radio buttons.
Note!The brouter function can only be enabled when the ED-20 is allowed to act as a
PPP client. (Refer to section 8.2.2 – General – Dial IN/OUT.)
Default: Off
Brouter Settings
IP Address
Allowed values: Should be in decimal dotted notation and in another Network ID than
the Local IP Address of the ED-20.
(Refer to section 8.2.3 – Ethernet Interface – Local IP Address)
Connect Message
This message will establish the modem connection.
Allowed values: Is decided by the attached modem.
Note! Refer to the user guide or installation manual to the attached modem.
8.2.5 Firewall settings
The firewall function will allow the network administrator to control the network access
and limit the traffic on the PPP link. It’s possible to accomplish this in two modes.
- Pass,Will only allow traffic where the source and destination IP address is present in
the entry list.
- Block,Will block traffic where either source or destination is present in the entry list.
See application exampes on page 31.
Firewall Mode
Disables or enables the Firewall mode with the radio buttons.
And selects if the firewall shall work in Block or Pass mode.
Default: Off
Firewall Settings
IP Address
Allowed values: Should be in decimal dotted notation and in another Network ID
than the Local IP Address of the ED-20.
(Refer to section 8.2.3 – Ethernet Interface – Local IP Address)
6609-2221
29
Download from Www.Somanuals.com. All Manuals Search And Download.
9. Application examples
Example of application with IP address settings.
Remote connection – LAN (Dial In)
IP: 169.254.100.101
GW: 169.254.100.100
169.254.100.100
255.255.255.
169.254.200.100
169.254.200.101
0
255.255.255.
0
PLC
ED-20
PPP
ROUTER
Serial Inter
face
ED-20
IP: 169.254.100.102
GW: 169.254.100.100
TD-33
TD-33
Remote connection
PSTN
PLC
DIAL IN
NO
+++
LAN – LAN (Leased Line)
IP: 179.254.100.101
GW: 179.254.100.100
IP: 169.254.100.101
GW: 169.254.100.100
179.254.100.100
255.255.255.
169.254.100.100
169.254.200.100
169.254.200.100
169.254.200.101
0
255.255.255.
0
169.254.200.101
255.255.255.
0
255.255.255.
0
PLC
PLC
Leased Line
ED-20
PPP
ED-20
PPP
ROUTER
Serial Inter
face
ROUTER
Serial Inter
face
ED-20
ED-20
IP: 179.254.100.102
GW: 179.254.100.100
IP: 169.254.100.102
GW: 169.254.100.100
TD-34
TD-34
L.L
L.L
PLC
PLC
DIAL IN/OUT
NO
DIAL IN/OUT
NO
LAN – LAN (PSTN, GSM)
PLC
9
8
7
6
5
4
3
2
1
ED-20
PPP
Serial Inter
ROUTER
face
ED-20
ID-90/V.90
TD-33/V.90
PLC
PSTN
PLC
DIAL IN/OUT
NO
ED-20
PPP
ROUTER
Serial Inter
NO
+++
2
face
ED-20
600
PSTN
PLC
DIAL IN/OUT
NO
NO
+++
2
600
GD-01
30
6609-2221
Download from Www.Somanuals.com. All Manuals Search And Download.
LAN – LAN (PSTN, Brouter, Firewall)
IP: 179.254.100.101
GW: 179.254.100.100
179.254.100.100
255.255.255.
169.254.200.100
169.254.200.101
0
255.255.255.
0
PLC
ED-20
PPP
ROUTER
Serial Inter
face
TD-34
ED-20
IP: 179.254.100.102
GW: 179.254.100.100
PLC
169.254.100.101 ATDnnnnnn
169.254.100.101
ATDnnnnnn
IP: 169.254.100.101
GW: 169.254.100.100
169.254.100.100
255.255.255.
169.254.200.100
169.254.200.101
0
255.255.255.
0
PLC
ED-20
PPP
Serial Interface
ROUTER
ED-20
IP: 169.254.100.102
GW: 169.254.100.100
TD-34
PLC
179.254.100.101
.
.
.
6609-2221
31