		 FEATURES   
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					High Efficiency: 91.0% @ 28V/12.5A   
					Size: 61.0x57.9x12.7mm (2.40”×2.28”×0.50”)   
					Standard footprint   
					Industry standard pin out   
					Fixed frequency operation   
					Metal baseplate   
					Input UVLO, Output OCP, OVP, OTP   
					Basic insulation   
					2250V isolation   
					2:1 Input voltage range   
					ISO 9001, TL 9000, ISO 14001, QS9000,   
					OHSAS18001 certified manufacturing facility   
					UL/cUL 60950-1 (US & Canada) recognized,   
					and TUV (EN60950-1) certified   
					CE mark meets 73/23/EEC and 93/68/EEC   
					directive   
					ꢀ 
					ꢀ 
					Delphi Series H48SN, 350W Half Brick Family   
					DC/DC Power Modules: 48V in, 28V/12.5A out   
					The Delphi Series H48SN Half Brick, 48V input, single output,   
					isolated DC/DC converters are the latest offering from a world leader   
					in power systems technology and manufacturing -- Delta Electronics,   
					Inc. This product family provides up to 350 watts of power in an   
					industry standard footprint. It provides 91% efficiency for 28V at full   
					load. With creative design technology and optimization of component   
					placement, these converters possess outstanding electrical and   
					thermal performance, as well as extremely high reliability under   
					highly stressful operating conditions. All models are fully protected   
					from abnormal input/output voltage, current, and temperature   
					conditions. The Delphi Series converters meet all safety   
					requirements with basic insulation. A variety of optional heatsinks are   
					available for extended thermal operation as well as for use in higher   
					air flow applications: 200 to 400 LFM.   
					OPTIONS   
					ꢀ 
					ꢀ 
					Positive Remote On/Off logic   
					Short pin lengths available   
					APPLICATIONS   
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					ꢀ 
					Telecom / Datacom   
					Wireless Networks   
					Optical Network Equipment   
					Server and Data Storage   
					Industrial / Testing Equipment   
					DATASHEET   
					DS_H48SN28012_01172008   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL CHARACTERISTICS CURVES   
					45.0   
					40.0   
					35.0   
					30.0   
					25.0   
					20.0   
					15.0   
					10.0   
					5.0   
					95   
					36Vin   
					48Vin   
					75Vin   
					36Vin   
					48Vin   
					75Vin   
					90   
					85   
					80   
					75   
					70   
					0 
					2 
					4 
					6 
					8 
					10   
					12   
					14   
					0.0   
					OUTPUT CURRENT (A)   
					0 
					2 
					4 
					6 
					8 
					10   
					12   
					14   
					OUTPUT CURRENT(A)   
					Figure 1: Efficiency vs. load current for minimum, nominal, and   
					Figure 2: Power dissipation vs. load current for minimum,   
					maximum input voltage at 25°C.   
					nominal, and maximum input voltage at 25°C.   
					14.0   
					Io=12.5A   
					Io=7.5A   
					Io=1.25A   
					12.0   
					10.0   
					8.0   
					6.0   
					4.0   
					2.0   
					0.0   
					30   
					35   
					40   
					45   
					50   
					55   
					60   
					65   
					70   
					75   
					INPUT VOLTAGE (V)   
					Figure 3: Typical input characteristics at room temperature   
					H48SN28012_01172008   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL CHARACTERISTICS CURVES   
					For Negative Remote On/Off Logic   
					Figure 4: Turn-on transient at full rated load current (resistive   
					Figure 5: Turn-on transient at minimum load current   
					load) (10ms/div). CH3: Vout;5V/div; CH1: ON/OFF input: 2V/div   
					(10ms/div). CH3: Vout: 5V/div; CH1: ON/OFF input: 2V/div   
					For Positive Remote On/Off Logic   
					Figure 6: Turn-on transient at full rated load current (resistive   
					load) (10ms/div). Top Trace: Vout; 5V/div; Bottom Trace:   
					ON/OFF input: 2V/div   
					Figure 7: Turn-on transient at zero load current (10ms/div). Top   
					Trace: Vout: 5V/div; Bottom Trace: ON/OFF input: 2V/div   
					H48SN28012_01172008   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL CHARACTERISTICS CURVES   
					Figure 8: Output voltage response to step-change in load   
					current (75%-50% of Io, max; di/dt = 1A/10µS). Load cap:   
					330µF aluminum,10uF Low ESR capacitor and 1µF ceramic   
					capacitor. Top Trace: Vout (100mV/div), Bottom Trace: Iout   
					(5A/div). Scope measurement should be made using a BNC   
					cable (length shorter than 20 inches). Position the load   
					between 51 mm to 76 mm (2 inches to 3 inches) from the   
					module.   
					Figure 9: Output voltage response to step-change in load   
					current (50%-75% of Io, max; di/dt = 1A/10µS). Load cap:   
					330µF aluminum,10uF Low ESR capacitor and 1µF ceramic   
					capacitor. Top Trace: Vout (100mV/div), Bottom Trace: Iout   
					(5A/div). Scope measurement should be made using a BNC   
					cable (length shorter than 20 inches). Position the load   
					between 51 mm to 76 mm (2 inches to 3 inches) from the   
					module.   
					Figure 10: Test set-up diagram showing measurement points   
					for Input Terminal Ripple Current and Input Reflected Ripple   
					Current.   
					Note: Measured input reflected-ripple current with a simulated   
					source Inductance (LTEST) of 12 μH. Capacitor Cs offset   
					possible battery impedance. Measure current as shown above.   
					H48SN28012_01172008   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL CHARACTERISTICS CURVES   
					Figure 11: Input Terminal Ripple Current, ic, at full rated output   
					current and nominal input voltage with 12µH source impedance   
					and 220µF electrolytic capacitor (1A/div).   
					Figure 12: Input reflected ripple current, is, through a 12µH   
					source inductor at nominal input voltage and rated load current   
					(10 mA/div)   
					Copper Strip   
					Vo(+)   
					SCOPE   
					RESISTIVE   
					LOAD   
					10u   
					1u   
					Vo(-)   
					Figure 13: Output voltage noise and ripple measurement test   
					setup   
					H48SN28012_01172008   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ELECTRICAL CHARACTERISTICS CURVES   
					30.0   
					25.0   
					20.0   
					15.0   
					10.0   
					5.0   
					Vin=48V   
					0.0   
					0 
					2 
					4 
					6 
					8 
					10 12 14 16 18 20   
					LOAD CURRENT (A)   
					Figure 14: Output voltage ripple at nominal input voltage and   
					rated load current (20 mV/div). Load capacitance:330uF   
					aluminum, 1µF ceramic capacitor and 10µFlow ESR capacitor.   
					Bandwidth: 20 MHz. Scope measurement should be made   
					using a BNC cable (length shorter than 20 inches). Position the   
					load between 51 mm to 76 mm (2 inches to 3 inches) from the   
					module.   
					Figure 15: Output voltage vs. load current showing typical   
					current limit curves and converter shutdown points.   
					H48SN28012_01172008   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				DESIGN CONSIDERATIONS   
					Input Source Impedance   
					ꢀ 
					ꢀ 
					ꢀ 
					The input source must be insulated from the ac   
					mains by reinforced or double insulation.   
					The impedance of the input source connecting to the   
					DC/DC power modules will interact with the modules   
					and affect the stability. A low ac-impedance input source   
					is recommended. If the source inductance is more than   
					a few μH, we advise adding a 220 to 470 μF electrolytic   
					capacitor (ESR < 0.1 Ω at 100 kHz) mounted close to   
					the input of the module to improve the stability.   
					The input terminals of the module are not operator   
					accessible.   
					If the metal baseplate is grounded, one Vi pin and   
					one Vo pin shall also be grounded.   
					Layout and EMC Considerations   
					ꢀ 
					A SELV reliability test is conducted on the system   
					where the module is used, in combination with the   
					module, to ensure that under a single fault,   
					hazardous voltage does not appear at the module’s   
					output.   
					Delta’s DC/DC power modules are designed to operate   
					in a wide variety of systems and applications. For design   
					assistance with EMC compliance and related PWB   
					layout issues, please contact Delta’s technical support   
					team. An external input filter module is available for   
					easier EMC compliance design. Application notes to   
					assist designers in addressing these issues are pending   
					release.   
					When installed into a Class II equipment (without   
					grounding), spacing consideration should be given to   
					the end-use installation, as the spacing between the   
					module and mounting surface have not been evaluated.   
					Safety Considerations   
					The power module has extra-low voltage (ELV) outputs   
					when all inputs are ELV.   
					The power module must be installed in compliance with   
					the spacing and separation requirements of the   
					end-user’s safety agency standard, i.e., UL60950,   
					CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and   
					IEC60950-1999, if the system in which the power   
					module is to be used must meet safety agency   
					requirements.   
					This power module is not internally fused. To achieve   
					optimum safety and system protection, an input line fuse   
					is highly recommended. The safety agencies require a   
					normal-blow fuse with 20A maximum rating to be   
					installed in the ungrounded lead. A lower rated fuse can   
					be used based on the maximum inrush transient energy   
					and maximum input current.   
					Basic insulation based on 75 Vdc input is provided   
					between the input and output of the module for the   
					purpose of applying insulation requirements when the   
					input to this DC-to-DC converter is identified as TNV-2   
					or SELV. An additional evaluation is needed if the   
					source is other than TNV-2 or SELV.   
					Soldering and Cleaning Considerations   
					Post solder cleaning is usually the final board assembly   
					process before the board or system undergoes electrical   
					testing. Inadequate cleaning and/or drying may lower the   
					reliability of a power module and severely affect the   
					finished circuit board assembly test. Adequate cleaning   
					and/or drying is especially important for un-encapsulated   
					and/or open frame type power modules. For assistance   
					on appropriate soldering and cleaning procedures,   
					please contact Delta’s technical support team.   
					When the input source is SELV, the power module meets   
					SELV (safety extra-low voltage) requirements. If the   
					input source is a hazardous voltage which is greater than   
					60 Vdc and less than or equal to 75 Vdc, for the module’s   
					output to meet SELV requirements, all of the following   
					must be met:   
					H48SN28012_01172008   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FEATURES DESCRIPTIONS   
					Vi(+)   
					Vo(+)   
					Over-Current Protection   
					Sense(+)   
					The modules include an internal output over-current   
					protection circuit, which will endure current limiting for   
					an unlimited duration during output overload. If the   
					output current exceeds the OCP set point, the modules   
					will automatically shut down (hiccup mode).   
					ON/OFF   
					Sense(-)   
					Vi(-)   
					Vo(-)   
					The modules will try to restart after shutdown. If the   
					overload condition still exists, the module will shut down   
					again. This restart trial will continue until the overload   
					condition is corrected.   
					Figure 16: Remote on/off implementation   
					Remote Sense   
					Over-Voltage Protection   
					Remote sense compensates for voltage drops on the   
					output by sensing the actual output voltage at the point   
					of load. The voltage between the remote sense pins   
					and the output terminals must not exceed the output   
					voltage sense range given here:   
					The modules include an internal output over-voltage   
					protection circuit, which monitors the voltage on the   
					output terminals. If this voltage exceeds the over-voltage   
					set point, the module will shut down and latch off. The   
					over-voltage latch is reset by either cycling the input   
					power or by toggling the on/off signal for one second.   
					[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout   
					This limit includes any increase in voltage due to   
					remote sense compensation and output voltage set   
					point adjustment (trim).   
					Over-Temperature Protection   
					The over-temperature protection consists of circuitry   
					that provides protection from thermal damage. If the   
					temperature exceeds the over-temperature threshold   
					the module will shut down.   
					Vi(+) Vo(+)   
					Sense(+)   
					The module will try to restart after shutdown. If the   
					over-temperature condition still exists during restart, the   
					module will shut down again. This restart trial will   
					continue until the temperature is within specification.   
					Sense(-)   
					Vi(-) Vo(-)   
					Contact   
					Resistance   
					Contact and Distribution   
					Losses   
					Remote On/Off   
					Figure 17: Effective circuit configuration for remote sense   
					operation   
					The remote on/off feature on the module can be either   
					negative or positive logic. Negative logic turns the   
					module on during a logic low and off during a logic high.   
					Positive logic turns the modules on during a logic high   
					and off during a logic low.   
					If the remote sense feature is not used to regulate the   
					output at the point of load, please connect SENSE(+) to   
					Vo(+) and SENSE(–) to Vo(–) at the module.   
					Remote on/off can be controlled by an external switch   
					between the on/off terminal and the Vi(-) terminal. The   
					switch can be an open collector or open drain.   
					The output voltage can be increased by both the   
					remote sense and the trim; however, the maximum   
					increase is the larger of either the remote sense or the   
					trim, not the sum of both.   
					For negative logic if the remote on/off feature is not   
					used, please short the on/off pin to Vi(-). For positive   
					logic if the remote on/off feature is not used, please   
					leave the on/off pin to floating.   
					When using remote sense and trim, the output voltage   
					of the module is usually increased, which increases the   
					power output of the module with the same output   
					current.   
					Care should be taken to ensure that the maximum   
					output power does not exceed the maximum rated   
					power.   
					H48SN28012_01172008   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				FEATURES DESCRIPTIONS (CON.)   
					Output Voltage Adjustment (TRIM)   
					To increase or decrease the output voltage set point,   
					the modules may be connected with an external   
					resistor between the TRIM pin and either the   
					SENSE(+) or SENSE(-). The TRIM pin should be left   
					open if this feature is not used.   
					Figure 19: Circuit configuration for trim-up (increase output   
					voltage)   
					If the external resistor is connected between the TRIM   
					and SENSE (+) the output voltage set point increases   
					(Fig. 19). The external resistor value required to obtain   
					a percentage output voltage change △% is defined   
					as:   
					Figure 18: Circuit configuration for trim-down (decrease   
					output voltage)   
					If the external resistor is connected between the TRIM   
					and SENSE (-) pins, the output voltage set point   
					decreases (Fig. 18). The external resistor value   
					required to obtain a percentage of output voltage   
					change △% is defined as:   
					) 
					Vo⋅ 100 + Δ%   
					100 + 2Δ%   
					Δ%   
					⎡ 
					⎣ 
					⎤ 
					⎦ 
					Rtrim up=   
					− 
					ΚΩ   
					1.225⋅Δ%   
					Ex. When Trim-up +10%(28.0V×1.1=30.8V)   
					100   
					⎛ 
					⎝ 
					⎞ 
					⎠ 
					Rtrim down=   
					Vo := 28.0V   
					Δ := 10   
					− 2 ΚΩ   
					Δ%   
					( 
					) 
					Ex. When Trim-down -60%(28.0V×0.6=16.8V)   
					Vo ⋅ 100 + Δ   
					100 + 2 ⋅ Δ   
					− 
					= 239.429 KΩ   
					Vo := 28.0 V   
					Δ := 40   
					1.225⋅ Δ   
					Δ 
					100   
					− 2 = 0.5K Ω   
					The output voltage can be increased by both the remote   
					sense and the trim, however the maximum increase is   
					the larger of either the remote sense or the trim, not the   
					sum of both.   
					Δ 
					When using remote sense and trim, the output voltage   
					of the module is usually increased, which increases the   
					power output of the module with the same output   
					current.   
					Care should be taken to ensure that the maximum   
					output power of the module remains at or below the   
					maximum rated power.   
					H48SN28012_01172008   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				THERMAL CONSIDERATIONS   
					Thermal management is an important part of the system   
					design. To ensure proper, reliable operation, sufficient   
					cooling of the power module is needed over the entire   
					temperature range of the module. Convection cooling is   
					usually the dominant mode of heat transfer.   
					Thermal Derating   
					Heat can be removed by increasing airflow over the module.   
					The module’s maximum case temperature is 110℃. To   
					enhance system reliability, the power module should always   
					be operated below the maximum operating temperature. If   
					the temperature exceeds the maximum module   
					temperature, reliability of the unit may be affected.   
					Hence, the choice of equipment to characterize the   
					thermal performance of the power module is a wind   
					tunnel.   
					THERMAL CURVES   
					Thermal Testing Setup   
					Delta’s DC/DC power modules are characterized in   
					heated vertical wind tunnels that simulate the thermal   
					environments encountered in most electronics   
					equipment. This type of equipment commonly uses   
					vertically mounted circuit cards in cabinet racks in which   
					the power modules are mounted.   
					The following figure shows the wind tunnel   
					characterization setup. The power module is mounted   
					on a test PWB and is vertically positioned within the   
					wind tunnel. The space between the neighboring PWB   
					and the top of the power module is constantly kept at   
					6.35mm (0.25’’).   
					Figure 21: Temperature measurement location   
					The allowed maximum hot spot temperature is defined at 110℃   
					H48SN28012NR A (Standard) Output Power vs. Hot Spot Temperature   
					PWB   
					Output Power (W)   
					(Either Orientation)   
					FACING PWB   
					400   
					350   
					300   
					250   
					200   
					150   
					100   
					50   
					MODULE   
					AIR VELOCITY   
					AND AMBIENT   
					TEMPERATURE   
					MEASURED BELOW   
					50.8 (2.0”)   
					12.7 (0.5”)   
					THE MODULE   
					AIR FLOW   
					0 
					25   
					35   
					45   
					55   
					65   
					75   
					85   
					95   
					105   
					Hot Spot Temperature(℃)   
					Figure 22: Output power vs. hot spot temperature (Either   
					Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)   
					Orientation)   
					Figure 20: Wind Tunnel Test Setup   
					H48SN28012_01172008   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				MECHANICAL DRAWING   
					Pin No.   
					Name   
					Function   
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					-Vin   
					Negative input voltage   
					Case ground   
					Remote ON/OFF   
					Positive input voltage   
					Positive output voltage   
					Positive remote sense   
					Output voltage trim   
					Negative remote sense   
					Negative output voltage   
					CASE   
					ON/OFF   
					+Vin   
					+Vout   
					+SENSE   
					TRIM   
					-SENSE   
					-Vout   
					Pin Specification:   
					Pins 1-4, 6-8   
					Pins 5 & 9   
					1.00mm (0.040”) diameter   
					2.00mm (0.079”) diameter   
					All pins are copper with Tin plating.   
					H48SN28012_01172008   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				PART NUMBERING SYSTEM   
					12   
					H 
					48   
					S 
					N 
					280   
					N 
					R 
					F 
					A 
					Form   
					Factor   
					H- Half   
					Brick   
					Input   
					Voltage   
					48V   
					Number of Product   
					Output   
					Voltage   
					280- 28V   
					Output   
					Current   
					ON/OFF   
					Logic   
					Pin   
					Length   
					Option Code   
					Outputs   
					Series   
					F- RoHS 6/6   
					(Lead Free)   
					S- Single   
					N- 350W   
					series   
					12- 12.5A N- Negative R- 0.170”   
					P- Positive N- 0.145”   
					A - Standard   
					Functions   
					K- 0.110” Space - RoHS   
					5/6   
					B - no thread   
					heatsink mounting   
					hole   
					MODEL LIST   
					MODEL NAME   
					INPUT   
					OUTPUT   
					EFF @ 100% LOAD   
					91%   
					H48SN28012NRFA   
					36V~75V   
					12.5A   
					28V   
					12.5A   
					Default remote on/off logic is negative and pin length is 0.170”   
					For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales   
					
					USA:   
					Telephone:   
					East Coast: (888) 335 8201   
					West Coast: (888) 335 8208   
					Fax: (978) 656 3964   
					Email: [email protected]   
					Europe:   
					Asia & the rest of world:   
					Telephone: +886 3 4526107 ext 6220   
					Fax: +886 3 4513485   
					Phone: +41 31 998 53 11   
					Fax: +41 31 998 53 53   
					Email: [email protected]   
					Email: [email protected]   
					WARRANTY   
					Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon   
					request from Delta.   
					Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its   
					use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted   
					by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications   
					at any time, without notice.   