Dell PowerEdge C5220
Using the Baseboard
Management Controller
COMMENT
COMMENT
COMMENT
COMMENT
COMMENT
COMMENT
COMMENT
COMMENT
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
5
5
5
5
6
8
8
9
10
11
13
13
13
16
16
16
17
18
19
20
21
22
22
23
24
26
28
3
Download from Www.Somanuals.com. All Manuals Search And Download.
29
32
34
35
36
40
42
44
45
45
49
51
51
52
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
This section introduces the Baseboard Management Controller (BMC) and
includes the requirements for web-based graphical user interface (GUI),
keyboard, video, and mouse (KVM), and virtual media.
Supported Platform
PowerEdge C5220
BMC Key Features and Functions
The following lists the supported features of the BMC:
•
•
•
•
Support for IPMI v1.5 and v2.0
Out-of-band monitoring and control for server management over LAN
Dedicated NIC for remote management via network
FRU information report, which includes main board part number, product
name, manufacturer, and so on.
•
•
•
Health status/hardware monitoring report
View and clear events log
Event notification by lighting chassis LED indicator and Platform Event
Trap (PET)
•
•
Platform Event Filtering (PEF) to take selected action for selected events
including NMI
Chassis management, which includes power control, status report, front
panel buttons, and LEDs control
•
•
Watchdog and auto server re-start and recovery
Support for multi-session user and alert destination for LAN channel
Using the Web UI
The BMC firmware features an embedded web server, enabling users to
connect to the BMC using an Internet browser (Microsoft Internet Explorer)
without needing to install KVM and virtual storage software on a remote
console.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Web-based GUI is supported on the following browsers:
Microsoft Windows:
•
•
Internet Explorer 6, 7 or later
Mozilla Firefox 2.0 or later
Linux:
Mozilla Firefox 2.0 or later
•
NOTE: Before using the web user interface, ensure that the firewall settings are
configured to enable access to the following ports: 8890 (KVM), 9000 (storage), 9001,
9002, and 9003.
Logging in to the Web User Interface
Enter the IP address or URL (default DHCP\static IP address) into the
address bar of the web browser.
When connecting to the BMC, the login screen prompts for the username
and password. This authentication with Secure Sockets Layer (SSL)
protection prevents unauthorized intruders from gaining access to the BMC
web server. Once authentication is passed, you can manage the server by
privilege.
Table 1-1. Default User Name And Password
Field
Default
User Name
root
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-1. Default User Name And Password
Field
Default
Password
root
NOTE: The default username and password are in lowercase characters. It is
advised to change the root password once you have logged in.
Click the Help button on the top right corner for assistance. Click Logout to
exit.
Menu Item
Description
System Information
Server Health
Displays the system information.
Displays the monitoring status of the
server.
Configuration
Allows the user to configure the IPMI
settings.
Remote Control
Allows the user to launch KVM console
and perform power control.
Maintenance
Language
Allows the user to do firmware update.
Allows the user to select a language
setting. (Currently, only support
English.)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
System Features
System Information
The System Information page enables you to view the BMC firmware version,
BIOS version, and Chassis version. Click System Information to view the
Remote Management Controller.
Table 1-2. BMC Summary
BMC Information
Description
Device Power Status
Firmware Revision
Current power state of the system.
Dell Remote Management Controller firmware version.
Aux Firmware Revision Firmware build number.
BIOS Version
BIOS version for the system.
Firmware Build Time
Date the firmware was last flashed in the form:
M DD YYYY HH:MM:SS
BMC Date & Time
Current date and time in the form:
W, DD M YYYY HH:MM:SS
BMC Chipset
Chassis Type
Chassis Version
MB Position
Dell Remote Management Controller type.
Displays the chassis type.
Displays the chassis version number.
Displays the current position of the mainboard within the
chassis.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Component Information
The Number of CPU Socket field and the Number of Memory Slot field
display the total number of motherboard supported.
CPU Information
Including CPU ID, Status, Socket, Manufacturer, Model, and Frequency.
Memory Information
Including Memory ID, Status, Socket, Module Size, Model, and Frequency.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Identify
The Server Identify page displays the indicator LED status. You can select a
Server Identify Operation to control the indicator LED functions.
Table 1-3. Server Identify
Item
Description
Current Server Identify Displays the current server identify status is on or off.
Server Identify
Operation
Select the server identify LED operation:
•
•
•
ON
OFF
Blink
Server Identify Timeout You can set the timeout value when you select the Blink
operation. The range is between 1 to 255 seconds, but note
255s is blinking continuously.
Perform Action
Click to execute the selected Server Identify Operation.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Firmware Update
Use the Firmware Update feature to upgrade to the latest firmware version.
The following data is included in the BMC firmware package:
•
•
•
Compiled BMC firmware code and data
Web-based user interface, JPEG, and other user interface data files
Default configuration files
Updating the BMC Firmware
NOTE: Before beginning the firmware update, download the latest firmware
version and save it on your local system. During the process of firmware update, the
AC power of the managed system cannot be unplugged and the Web GUI cannot be
closed.
NOTE: Once you enter into Update Mode and choose to cancel the firmware flash
operation, the BMC must be reset. This means that you must close the Internet
browser and log back onto the BMC card before you can perform any other types of
operations.
Select the Enter Update Mode button from the Maintenance tab to put the
device in a special mode that allows firmware update. You can now follow the
instructions presented below to successfully update the card’s firmware. The
device resets if update is cancelled. The device also resets upon successful
completion of firmware update.
1
Browse to, or enter the path on your system where the firmware image file
resides.
Example:
C:\Updates\V1.0\<image_name>
The default firmware image name is s81kXXX.bin (whereas XXX is the
version number).
2
3
Select Auto Reset BMC if you want the BMC to auto reset after the
update.
BMC will not check if the Firmware image belongs to C5220 platform
when selecting Force Update
.
4
5
Click the Upload Firmware button.
BMC will save configure settings when Preserve Configuration is selected.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Click Start Upgrade.
The update might take several minutes. When the update is completed, a
dialog box appears.
7
8
Click OK to close the session and automatically log out.
After the BMC resets, click Log In to log in to the BMC again.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Front Panel User Interface
The BMC provides control panel interface functionality including indicators
(fault, status, and ID LEDs) and buttons (power/ID).
Power Button
The power button turns the device on and off.
The power button has a deferred mechanism. When the DC is off the power button
ignores one (1) second or less activation to protect against accidental DC power on.
LEDs
BMC Heartbeat LED
The green LED provides an easy way to indicate that BMC is now enabled.
ID LED
A blinking LED indicates the Chassis Identify command has been accepted.
System Status LED
There is a dual-color LED to show the system status. The BMC turns the
LED off after all event logs are cleared.
The behavior of Status LED and ID LED is listed in Table 1-2.
Table 1-4. LED Status
LED
Color Status
Occurrence
Note
Off
Green Solid On Power On (S1/S0)
Off Power Off (S4/S5)
Normal status
The power LED status is
controlled by BIOS.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-4. LED Status
LED
Color Status
Blue Off
Occurrence
Normal status (by IPMI Turn off the ID LED.
Chassis Identify 1. ipmitool raw 0x00 0x04
command or System ID 0x00
Button) 2. ipmitool raw 0x00 0x04
Note
ID LED
0x00 0x00
Solid On Identify the system
Turn on the ID LED.
1.ipmitool raw 0x00 0x04 0x3c
01
Blinking Identify the system with 1. IPMI chassis identify
interval
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60 sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)
Heartbeat Green Off
LED
BMC is not ready
Blinking BMC is ready
Table 1-5. Blinking Fault LED Conditions
Index
Sensor Name
Event Triggers
1
CPU Temp
• Upper Critical Going High
• Upper Non-Critical Going High
Ambient Temp,
DIMM Temp
Rear Temp 1
Rear Temp 2
Rear Temp 3
SLED 12V
2
• Upper Critical Going High
• Upper Non-Critical Going High
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
3
Sensor Name
Event Triggers
BMC Watchdog
• Timer expired
• Hard reset
• Power down
• Power cycle
4
5
Processor
• IERR
• Thermal trip
BMC SEL
• SEL full (909 records)
• SEL almost full (909 x 75% = 681 records)
State Asserted
6
7
8
Processor Hot
System Event
PCIE Error
PEF action
Bus correctable error
Bus Uncorrectable error
Bus fatal
9
POST Error
System firmware error
• Correctable error
• Uncorrectable error
• Correctable ECC error logging limit reached
10
CPU1_DIMM A1
CPU1_DIMM A2
CPU1_DIMM A3
CPU1_DIMM A4
11
12
SYS FAN 1 ~
SYS FAN 8
• Lower critical going low
• Lower non-critical going low
• Presence detected
PSU 1 Status
PSU 2 Status
• TEMPERATURE Failure detected
• IOUT Failure detected
• VOUT Failure detected
• FANS Failure detected
• INPUT Failure detected
Redundancy lost
13
14
PSU Redundancy
Mixed MB
• Mixed MB detected
• Key Slot error detected
15
Download from Www.Somanuals.com. All Manuals Search And Download.
System Information
System Information
The System Information page shows general information about the system
including Device Power Status, Firmware Revision, AuxFirmware Revision,
Firmware Build Time, BMC Chipset, BIOS Version, and Chassis Version.
List FRU
The List FRU page shows a list of the detected Field Replaceable Units
(FRUs) in the system. Select a FRU item from the drop down list to show
more information.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Component Information
The Component Information page shows a table of the components. The
components can be filtered by category and can be sorted by the column
header. The table shows the Socket, Manufacturer, and Model of each
component.The Number of CPU Socket field and the Number of Memory
Slot field display the total number of motherboard supported.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Health
The Server Health page provides information about the server’s health such
as sensor readings and the event log. The sensor readings can be shown with
or without thresholds in the table.
Table 1-6. Server Health Options
Button
Description
Sensor Readings
This button allows you to view the readings from the
various sensors.
Sensor Readings with
Thresholds
This button allows you to view the readings from the
various sensors, with thresholds included in the table.
Event Log
This button allows you to view the event logs written to the
event log table.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Sensor Readings
The Sensor Readings page shows all sensor readings from the system.
NOTE: The sensor type category displays the full sensor (threshold-base) type only.
Table 1-7. Sensor Readings
Button
Description
Name
Name of the sensor.
Status
Shows the current status of the sensor.
The current value of the sensor.
Click to refresh the current table.
Click to see the threshold value of the sensor.
Reading
Refresh
Show Thresholds
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Sensor Readings With Thresholds
The Sensor Readings with Thresholds page shows all sensor readings and
thresholds from the system.
Table 1-8. Sensor Readings With Thresholds
Item
Description
Sensor Selection Drop
Down Menu
This drop-down menu allows you to select the type of
sensor readings that you want to show in the list.
• All Sensors
• Temperature Sensors
• Current Sensors
• Fan Sensors
Sensor Readings List
This field shows the individual sensor’s name, reading and
the current status of the sensor. It also shows the following
threshold settings for every sensor.
• Low NR: lower non-recoverable
• Low CT: lower critical
• Low NC: lower non-critical
• High NC: upper non-critical
• High CT: upper critical
• High NR: upper non-recoverable
Click to refresh the current table.
Refresh Button
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-8. Sensor Readings With Thresholds
Item Description
Hide Thresholds Button Clicking Hide Thresholds button reduces the sensor
reading table and hides the various threshold settings for
every sensor.
Temperature Monitoring
The system supports the following temperature sensors.
Table 1-9. Temperature Sensors (8-Sled Chassis)
Temperature
CPU Temp
Sensor Number
0x44
UNCT
77
UCT
82
47
72
47
47
47
Ambient Temp
DIMM Temp
Rear Temp 1
Rear Temp 2
Rear Temp 3
0x40
44
0x4C
68
0x54
46
0x55
46
0x56
46
Table 1-10. Temperature Sensors (12-Sled Chassis)
Temperature
CPU Temp
Sensor Number
0x44
UNCT
71
UCT
76
47
72
47
47
47
Ambient Temp
DIMM Temp
Rear Temp 1
Rear Temp 2
Rear Temp 3
0x40
44
0x4C
68
0x54
46
0x55
46
0x56
46
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Current Monitoring
management used.
Table 1-11. Current Monitoring
Current
Sensor Number
UNCT
UCT
SLED 12V
0x4E
216
252
FAN Control and Monitoring
The BMC receives all fan tachometers of the threshold base from the chassis
controller. The following is the table of the fan speed thresholds.
Table 1-12. Fan Thresholds
Fan Sensor
Sensor
LCT
LNCT
Number
SYS FAN 1
SYS FAN 2
SYS FAN 3
SYS FAN 4
SYS FAN 5
SYS FAN 6
SYS FAN 7
SYS FAN 8
0x68
0x69
0x6A
0x6B
0x6C
0x6D
0x6E
0x6F
600 rpm
600 rpm
600 rpm
600 rpm
600 rpm
600 rpm
600 rpm
600 rpm
720 rpm
720 rpm
720 rpm
720 rpm
720 rpm
720 rpm
720 rpm
720 rpm
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Event Log
The Event Log page shows the event logs from the managed system.
NOTE: If the event log belongs to the OEM SEL Record, the Sensor Type field will
display the Manufacturer ID and the Description field will display the raw data of
the OEM Defined field. Because these logs are recorded by the OS, and need to be
decoded by OS, please use the Windows Event Viewer to get further data.
Table 1-13. Event Log
Item
Description
Select An Event Log
Category
Select one of the following event categories:
• All Event Logs
• Sensor-Specific Events
• BIOS-Generated Events
• System Management Software Events
Event Log
You can obtain the following information for each event:
• Event ID
• Time Stamp
• Sensor Name
• Sensor Type
• Description
Refresh Button
Use this button to refresh the event logs view.
Clear Event Log Button Click the Clear Event Log button to clear the event logs.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuration
The Configuration menu allows you to access various configuration settings
including Alerts, Mouse Mode, Network, SOL, SNMP, SMTP, Users, PEF, SSL
Certification and Web Session settings.
Table 1-14. Configuration Options
Button
Description
Alerts Button
This button takes you to the Alert list page where you can
add, edit or remove alert destinations.
Mouse Mode Button
This button takes you to the Mouse Mode settings page
where you can view the current setting and/or change the
mode of your pointing device to/from either Relative or
Absolute.
Network Button
SOL
This button takes you to the Network settings page where
you can view the MAC address or change network settings,
including the dynamic and static IP assignment.
This buttons takes you to the Serial Over Lan settings
page, where you can enable SOL and channel privilege
level limits.
SNMP
This button takes you to the SNMP community string
page for the SNMP trap server where you can modify the
string and save the settings.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-14. Configuration Options
Button
Description
SMTP
This button takes you to the SMTP settings page where
you can configure the SMTP mail server.
Users
PEF
This button takes you to the user list page where you can
add, edit or remove users.
This button takes you to the PEF list page where you can
configure PEF settings including Event Filter Action, Alert
Policy Number, Sensor Type, and Event Trigger.
SSL Certificate
Web Session
This button takes you to the SSL certificate page where
you can upload an SSL Certificate.
This button takes you to the Web session configuration
page where you can modify the web session timeout value.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Alerts
When BMC sends a platform event, such as an environment warning or a
component failure, an alert message may be sent to one or more email
addresses / IP addresses. On the Alerts page, you can configure alert
destinations. To delete an alert, select it and press Delete. To create a new
alert, select a destination address that has not been configured, yet, from the
alert table entry and click Modify. To send a test alert, select the alert from
the list and click the Send Test Alert button.
Table 1-15. Alerts
Item
Description
Alert Policy #
Destination Address
Lists all alert entries.
Lists the SNMP trap destination IP address or email
address for the listed entries.
Modify Button
This button takes you to the Modify Alerts page. You can
add a new alert configuration entry or modify an existing
entry.
Send Test Alert Button Select an alert entry and press Send Test Alert to send a
test alert.
Delete Button
Select an alert configuration entry and press Delete to
delete the entry.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Modify Alert
Table 1-16. Modify Alerts
Items
Description
Alert Type
You can select the way an alert is sent when it is triggered by an
event.
• SNMP Trap
• Email
NOTE: If you select SNMP Trap as the Alert Type, Email Address,
Subject, Message is disabled. If you select Email as the Alert
Type, Destination IP is disabled.
Destination IP
Email Address
Subject
Type the SNMP destination IP address into this field, when
you select SNMP Trap as the Alert Type.
Type the Email address into this field, when you select Email as
the Alert Type.
Type a Subject into this field, when you select Email as the
Alert Type.
Message
Type a Message into this field, when you select Email as the
Alert Type.
Save
Use this button to save your settings.
Use this button to cancel your action.
Cancel
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Mouse Mode
On the Mouse Mode page, you can configure the mouse mode options.
Table 1-17. Mouse Mode
Item
Description
Current Mouse Mode
Absolute or Relative.
NOTE: Both Absolute and Relative modes enable you to see
two mouse cursors where, the redirected host mouse cursor
and the actual local mouse cursor. When the single cursor
checkbox is selected, only the redirect mouse cursor is
visible.
Set Mode to Absolute
Option
Select this option to select mouse mode to Absolute,
depending upon your system.
Set Mode to Relative
Option
Select this option to select mouse mode to Relative,
depending upon your system. If you select the single
mouse checkbox, it locks the local mouse cursor inside the
redirected window and the user has to press <Alt+M> to
unlock and stop mouse redirection. Here <Alt+M> is
basically used to start or stop mouse redirection.
Save Button
Use this button to make the settings active.
IPMI is an OS-independent platform, and KVM support is an added feature
for IPMI. For your mouse to function properly, please configure the mouse
mode settings according to the mouse is absolute coordinates or relative
28
Download from Www.Somanuals.com. All Manuals Search And Download.
coordinates on your host server. For example, it is recommended to use
absolute / relative mouse mode when your host server is running in Windows
or Linux.
NOTE: When you choose the relative mouse mode. The redirected host mouse
cursor may not overlap with the actual local mouse cursor (depending on the
mouse cursor acceleration setting of the host OS). If this situation occurs, it is
recommended to select the single cursor checkbox.
Network
The Network page allows you to view and modify the network settings. Select
whether to obtain an IP address automatically or manually configure one.
NOTE: To change any of the settings on the Network Configuration page, you must
have permission to configure the BMC. Do not do network configuring when the
server is in BIOS mode; the network configuration may be conflict with the BIOS.
Table 1-18. Network
Item
Description
MAC Address
This field shows the MAC address.
Obtain an IP address
This option allows the BMC’s IP to be configured by a DHCP
automatically (use DHCP) server (dynamically).
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-18. Network
Item
Description
Use the following IP
address
This option allows you to configure a static IP. The IP Address,
Subnet Mask, and Gateway fields become editable when this
option is selected.
IP Address
This field allows you to set the BMC’s IP address.
This field allows you to set the Subnet Mask.
Subnet Mask
Default Gateway
This field allows you to set the BMC’s Gateway access address.
Obtain DNS IP address
automatically
This option allows the DNS IP to be configured by a DHCP
server (dynamically).
Use the following DNS IP This option allows you to configure the DNS IP address with a
address
static IP. The Primary and Secondary DNS Server will become
editable when this option is selected.
Primary DNS Server
Specify the IP address of the preferred DNS server.
Secondary DNS Server
Specify the alternative IP address to be used when the preferred
DNS server is not available.
Enable DNS Register BMC When checked, it will register with the Domain Name Server.
Host Name
DNS BMC Host Name field will become read-only when this
option is selected.
DNS BMC Host Name
Specifies the DNS BMC host name.
Enable DNS Domain
Name (use DHCP)
Enable / disable acquisition of DNS Domain Name from DHCP
server. DNS Domain Name field will become read-only when this
option is selected.
DNS Domain Name
Save Button
Specified the DNS domain name.
Use this button to save your settings.
NOTE: If you configure the IP address with a static IP, you can’t get the DNS IP
address from the DHCP server.
NOTE: If you want to update the DNS information with the DNS server, you must
select “Obtain an IP address automatically” to get IP address dynamically. And the
DNS server IP will provide by the DHCP server.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
VLAN Settings
Table 1-19. VLAN Settings
Items
Description
Enable VLAN
Enable / disable VLAN function.
Note: If enabled, BMC will only accept packets for this channel
if they have 802.1q fields and their VLAN ID matches the
VLAN ID field.
VLAN ID
Identification for VLAN Interface. The range of VLAN ID is
from 2 to 4094.
VLAN Priority
The range of VLAN Priority is from 0 to 7 (7 is the highest
priority). This field can be set only if user login web page via
VLAN interface.
Save
Use this button to save your settings.
Cancel
Use this button to cancel your action, and back to network
settings page.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
SOL
The SOL page allows you to configure the Serial Over LAN settings, select or
change pertinent values for each attribute and save any changes.
Table 1-20. Serial Over LAN Settings
Item
Description
Enable Serial Over LAN
Check this field to enable (checked) or disable (unchecked) Serial
Over LAN.
Channel Privilege Level
Limit
Select the IPMI Serial Over LAN (minimum) user privileges:
• Administrator
• Operator
• User
Save
Use this button to save any settings changes.
Use this button to enter the Advanced SOL page.
Advanced SOL Settings
32
Download from Www.Somanuals.com. All Manuals Search And Download.
SOL Advanced Settings
Table 1-21. Advanced SOL settings
Item
Description
Character
The amount of time that the BMC will wait before
Accumulate Interval transmitting a partial SOL character data package. 1-based
5ms increments. This value must be less than 255.
Character Send
Threshold
The BMC will send an SOL character data package containing
the characters as soon as this number of characters (of greater)
has been accepted. 1-based units. This value must be less than
255.
Save
Use this button to save your advanced settings.
Use this button to back to SOL page.
Cancel
33
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP
The SNMP page displays the community string page for the SNMP trap server. You
can modify the community string and save the new settings.
Table 1-22. SNMP
Item
Description
Community String
In the field, enter the SNMP community string for the
destination IP address.
Save Button
Use this button to save the new settings.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
SMTP
The SMTP page allows you to configure the SMTP mail server.
Table 1-23. SMTP
Item
Description
Mail Server IP
This field allows you to configure the IP address of the SMTP
mail server.
Save Button
Use this button to save your settings.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Users
The Users page allows you to view the current list of user for the server. If you
would like to delete or modify a user, select their name in the list and click
Delete User or Modify User. To add a new user, select an un-configured slot
and select Add User
NOTE: Only user accounts over administrative rights are allowed to add, edit and
delete users, but administrative level privileges still can’t delete root, anonymous
and itself. If a new user is given administrative privileges, permissions are
automatically granted for all interfaces.
Item
Description
UserID Column
This column shows the ID number used in association
with the User Name.
User Name Column
This column shows a list of all users who are able to access
this BMC.
NOTE: The default administrator is root. It is prudent for you
to change the root password.
Network Privilege
Column
This column shows the network rights associated with the
account.
Add User Button
Use this button to add a new user. Select an open field
first.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Modify User Button
Use this button to modify an existing user. Select a user
first.
Delete User Button
Use this button to delete an existing user. Select a user
first.
Add New User
Add New User
Item
Description
User Name
Enter a user name in the user name field. Your user name
must be a string of 4 to 15 alpha-numeric characters.User
names are case-sensitive and must start with an
alphabetical character.
Password
Enter a password in the Password field. Your password must
be a string of 8 to 20 alpha-numeric characters.
NOTE: Use a combination of alphanumeric and special
characters for better security. The password is case-
sensitive.
Confirm Password
Confirm your password by entering your password again in
the Confirm Password field.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Add New User
Item
Description
Network Privileges Drop Assign network permissions and access rights to any of the
Down Menu
following:
• User
• Operator
• Administrator
• OEM Proprietary
• No Access
Add Button
Use this button to add the new user.
Use this button to cancel this action.
Cancel Button
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Modify User
Table 1-24. Modify User
Item
Description
User Name
This field contains the user name being modified. This field
cannot be modified.
Change Password Box Select this box to change the password.
Password
Enter a password in the Password field. Your password must be
a string of 8 to 20 alpha-numeric characters.
NOTE: Use a combination of alphanumeric and special
characters for better security. The password is case-sensitive.
Confirm Password
Confirm your password by entering your password again in the
Confirm Password field.
Network Privileges
Drop Down Menu
Modify network permissions and access rights to any of the
following:
• User
• Operator
• Administrator
• OEM Proprietary
• No Access
Modify Button
Cancel Button
Use this button to update the user account.
Use this button to cancel this action.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
PEF
The PEF page allows you to configure the platform event filters. The
Platform Event Filters List displays the actions that will execute when an
event occurs. An event occurs when the status of a system element is outside
a set limit. You can select a PEF and press the Modify button to configure it.
Or you can press Delete to remove it.
Table 1-25. PEF
Item
Description
PEF#
Number of PEF configuration entry. There are 40 PEF
configuration entries in the system.
Event Filter Action
Sensor Type
Specify the corresponding action for a PEF triggered event.
Displays the sensor type.
Sensor Num
Displays the sensor number.
Event Trigger
Show the threshold type to cause the event occurs.
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Modify PEF
Change the attributes, and click the Save button to save any changes. If you
want to cancel this action, click the Cancel button to return to PEF list page.
Table 1-26. Modify PEF
Item
Description
Event Filter
Action
Check/uncheck the Alert box to enable/disable alert occurs. You can select one
of power operation. If event occurs, the power action will perform.
•
•
•
•
No Power Action
Power Down
Reset
Power Cycle
Alert Policy
Num
Choose the alert policy number of the Alerts List.
Sensor Type
Select the sensor type.
Sensor Num Enter the sensor number.
Event Trigger Choose the event trigger type.
•
•
Any: choose all trigger type events
Select: choose a single trigger type event
Filter
Check/uncheck this box to enable/disable this filter.
Enable/Disable
41
Download from Www.Somanuals.com. All Manuals Search And Download.
SSL Certificate
The SSL Certificate page allows you upload a new SSL certificate.
The SSL page does not support encryption of private keys, for example: DES, AES,
etc. Upload unencrypted private key to access support.
Table 1-27. PEF
Item
Description
Default Certificate Displays the time of creation of the default certificate.
Default Privacy Key Displays the time of creation of the existing privacy key.
New SSL Certificate Use the Browse button to select a new certificate to upload.
Upload Button
Use this button to upload the previously selected certificate.
The Certificate file name should end with the file suffix .pem or .crt. After
you click on the Upload button, the new SSL certificate will replace the
existing certificate.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Uploading Private Key
Table 1-28. SSL Private Key Upload web page
Item
Description
Default Certificate Displays the creating time of the existing certificate.
Default Privacy Key Display the creating time of the existing privacy key.
New Private Key
Upload
Click to choose the new Private Key that you want to upload.
Click to start upload Private Key.
The Private Key file name should end with .pem or .key. After you upload the
new Private Key, the web server will restart. You must close this browser
session and open a new browser session to reconnect to the device.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Web Session
The Web Session page allows you to change web session time out values. The
default value is 300 seconds. If you don't active web within 300 seconds, the
web session will time out and you must login again.
Table 1-29. PEF
Item
Description
Never Time Out
This option allows the web session never time out.
Setting Time Out
Seconds
This option allows you to configure the web session time out
value. The Time Out field will become editable when this
option is selected.
Time Out
Save
Specify the time out value.
NOTE: The Time Out value must be between 30 to 7200 seconds.
The default value is 300 seconds.
Use this button to save your settings.
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Control
The Remote Control menu allows you to initiate Console Redirection and to
view the Power Control options.
NOTE: The Console Redirection page is ONLY enabled in the AST2050 BMC
chipset.
Console Redirection
The Console Redirection page enables you to use the display, mouse, and
keyboard on the local management station to control the corresponding
devices on a remote managed system. Click on Java Console to launch the
Java-based remote console.
NOTE: Before you can use the Console Redirection feature, your browser must
have the JRE installed in your operating system. The umber of sessions allowed is
two.
NOTE: The recommended display resolution on the management station (or client)
is at least 1024 x 768 pixels at 60 Hz with 32 bit color. You cannot view the console in
full screen mode if your monitor resolution is less than the minimum.
NOTE: If Console Redirection is launched and not closed, the web session timeout
function is closed.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-30. Console Redirection, Java Console Launch
Item
Description
Java Console
Use this button to launch the redirection console using
Java viewer.
Table 1-31. Remote Console Shortcut Key Combinations
Keystroke
Description
<ALT+S>
<ALT+T>
<ALT+R>
<ALT+F>
<ALT+M>
<ALT+A>
<ALT+B>
<ALT+L>
<ALT+N>
<ALT+D>
<ALT+E>
Start Console Redirection
Stop Console Redirection
Restart Console Redirection
Toggle Full Screen Mode
Synchronize Mouse
Hold/Unhold Right <ALT> Key
Hold/Unhold Left <ALT> Key
Hold/Unhold Right <CTRL> Key
Hold/Unhold Left <CTRL> Key
Generate <CTRL>, <ALT>, + <DEL>
Start CD-ROM Drive Redirection
Table 1-32. Console Redirection Window: Keyboard
Menu Item
Description
Hold Right Ctrl Key
This menu item can be used to act as the right-side
<CTRL> key when in Console Redirection.
Hold Right Alt Key
Hold Left Ctrl Key
Hold Left Alt Key
This menu item can be used to act as the right-side
<ALT> key when in Console Redirection.
This menu item can be used to act as the left-side
<CTRL> key when in Console Redirection.
This menu item can be used to act as the left-side <ALT>
key when in Console Redirection.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-32. Console Redirection Window: Keyboard
Menu Item
Description
Left Windows Key
This menu item can be used to act as the left-side
<WIN> key when in Console Redirection. You can also
decide how the key should be pressed:
• Hold Down
• Press and Release
Right Windows Key
<Alt+Ctrl+Del>
This menu item can be used to act as the right-side
<WIN> key when in Console Redirection. You can also
decide how the key should be pressed:
• Hold Down
• Press and Release
This menu item can be used to act as if you pressed the
<CTRL>, <ALT> and <DEL> keys down
simultaneously on the server that you are redirecting.
Table 1-33. Console Redirection Window: Mouse
Menu Item
Description
Sync Cursor
This menu item can be used to synchronize or un-
synchronize the mouse cursor.
Show Cursor
This menu item can be used to show or hide the local
mouse cursor on the remote client system.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-34. Console Redirection Window: Options
Item
Description
Bandwidth
The bandwidth usage option allows you to adjust the
bandwidth. You can select one of the following:
• Auto Detect
• 256 Kbps
• 512 Kbps
• 1 Mbps
• 10 Mbps
• 100 Mbps (Default Setting)
KB/Mouse Encryption
This option allows you to encrypt keyboard inputs and
mouse movements sent between the connections.
Table 1-35. Console Redirection Window: Options
Item
Description
Video Settings
Hide the hardware cursor, and transmit video deltas only.
Video Engine
Configuration Settings
• Compression Mode: YUV compression, where Y is
luminance and UV is chrominance.
• DCT Quantization Table: number to control DCT
quality.
Table 1-36. Console Redirection Window: Device
Menu Item
Description
Redirect CDROM
This menu item can be used to start or stop the redirection
of a physical DVD/CD-ROM drive.
Redirect ISO
This menu item can be used to start or stop the redirection
of a DVD/CD ISO image.
Redirect Floppy/USB
Key
This menu item can be used to start or stop the redirection
of a physical floppy/USB key drive.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-36. Console Redirection Window: Device
Menu Item
Description
Redirect Floppy/USB
Key Image
This menu item can be used to start or stop the redirection
of a floppy/USB key image, instead of a physical driver.
Table 1-37. Console Redirection Window: Help
Menu Item
Description
About JViewer
Shows the copyright and version information.
Power Control
The Power Control page allows you to view and control the power of your
server. Select one of the options listed in the following table to execute on
your server. You are asked to confirm your choice. Upon confirmation, the
command is executed and you are informed of the status.
Table 1-38. Power Control and Status
Menu Item
Description
Reset Server Option
Select this option to reset the server.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-38. Power Control and Status
Menu Item
Description
Power Off Server -
Immediate Option
Select this option to power down the server immediately.
Power Off Server -
Orderly Shutdown
Option
Select this option to power down the server gracefully.
Power On Server Option Select this option to power up the server.
Power Cycle Server
Option
Select this option to power cycle the server.
Perform Action Button Select this button to execute the option selected.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
The Maintenance menu allows you to perform maintenance tasks on the
device including the Firmware Update. Refer to "Firmware Update" on
Languages
The Languages menu allows you to select the language for the web
application. Select the language from the drop down list and click Apply.
NOTE: The web interface needs to reload for the change to take effect.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
IPMI 1.5 / 2.0 Command Support List
Table 1-39. IPMI Device Global Commands
Command
NetFn
App
App
App
App
App
App
App
App
CMD
01h
02h
03h
04h
05h
06h
07h
08h
O/M
M
O
Supported
Yes
Get Device ID
Cold Reset
Yes
Warm Reset
O
No
Get Self Test Results
Manufacture Test On
Set ACPI Power State
Get ACPI Power State
Get Device GUID
Broadcast Command:
Broadcast ‘Get Device ID’
M
O
Yes
Yes
O
Yes
O
Yes
O
Yes
App
01h
M
No
Table 1-40. BMC Device and Messaging Commands
Command
NetFn
App
App
App
App
App
CMD
2Eh
2Fh
30h
O/M
M
Supported
Yes
Set BMC Global Enables
Get BMC Global Enables
Clear Message Buffer Flags
Get Message Buffer Flags
M
Yes
M
Yes
31h
M
Yes
Enable Message Channel
Receive
32h
O
Yes
Get Message
App
App
App
App
App
33h
34h
35h
36h
37h
M
M
O
Yes
Yes
Yes
No
Yes
Send Message
Read Event Message Buffer
Get BT Interface Capabilities
Get System GUID
M
O
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-40. BMC Device and Messaging Commands
Command
NetFn
App
CMD
38h
O/M
O
Supported
Yes
Get Channel Authentication
Capabilities
Get Session Challenge
App
App
App
39h
3Ah
3Bh
O
O
O
Yes
Yes
Yes
Activate Session Command
Set Session Privilege Level
Command
Close Session
App
App
App
3Ch
3Dh
3Fh
O
O
O
Yes
Yes
Yes
Get Session Information
Get Authentication Code
Command
Set Channel Access Commands App
Get Channel Access Commands App
40h
41h
42h
43h
44h
45h
46h
47h
48h
49h
4Ah
4Bh
O
O
O
O
O
O
O
O
O
O
O
O
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Get Channel Info Command
Set User Access Commands
Get User Access Commands
Set User Name Commands
Get User Name Commands
Set User Password Commands
Active Payload Command
App
App
App
App
App
App
App
App
App
App
Deactivate Payload Command
Get Payload Activation Status
Get Payload Instance Info
Command
Set User Payload Access
App
App
App
App
4Ch
4Dh
4Eh
4Fh
50h
O
O
O
O
O
Yes
Yes
Yes
Yes
Yes
Get User Payload Access
Get Channel Payload Support
Get Channel Payload Version
Get Channel OEM Payload Info App
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-40. BMC Device and Messaging Commands
Command
NetFn
App
CMD
52h
O/M
M
Supported
Yes
Master Write-Read I2C
Get Channel Cipher Suites
App
54h
O
Yes
Suspend/Resume Payload
Encryption
App
55h
O
Yes
Set Channel Security Keys
App
App
56h
57h
O
O
Yes
Yes
Get System Interface
Capabilities
Table 1-41. BMC Watchdog Timer Commands
Command
NetFn
App
App
App
CMD
22h
24h
25h
O/M
M
Supported
Yes
Reset Watchdog Timer
Set Watchdog Timer
Get Watchdog Timer
M
Yes
M
Yes
Table 1-42. Chassis Commands
Command
NetFn
CMD
00h
01h
02h
03h
04h
05h
06h
07h
08h
09h
0Ah
0Bh
O/M
M
M
M
O
Supported
Yes
Get Chassis Capabilities
Get Chassis Status
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Chassis
Yes
Chassis Control
Yes
Chassis Reset
No
Chassis Identify
O
Yes
Set Chassis Capabilities
Set Power Restore Policy
Get System Reset Cause
Set System Boot Options
Get System Boot Options
Set Front Panel Button Enable
Set Power Cycle Interval
O
Yes
O
Yes
O[1]
O
Yes
Yes
O
Yes
O
Yes
O
Yes
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-42. Chassis Commands
Command
NetFn
CMD
O/M
Supported
Get POH Counter
Chassis
0Fh
O
Yes
[1] Optional portion of Get System Reset Cause is not support.
Table 1-43. Event Commands
Command
NetFn
CMD
O/M
Event
Receiver Generator
Supported
Even
Set Event Receiver
Get Event Receiver
Platform Event
S/E
S/E
S/E
00h
01h
02h
M
M
M
M
M
M
Yes
Yes
Yes
Table 1-44. SEL Commands
Command
NetFn
CMD
40h
41h
42h
43h
44h
45h
46h
47h
48h
49h
5Ah
5Bh
O/M
Supported
Yes
Get SEL Info
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
M
O
Get SEL Allocation Info
Reserve SEL
Yes
O
Yes
Get SEL Entry
M
M
M
O
Yes
Add SEL Entry
Yes
Partial Add SEL Entry
Delete SEL Entry
Clear SEL
Yes
Yes
M
M
M
O
Yes
Get SEL Time
Yes
Set SEL Time
Yes
Get Auxiliary Log Status
Set Auxiliary Log Status
No
O
No
NOTE: Support for Partial Add SEL is not required when Add SEL is supported.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-45. SDR Repository Commands
Command
NetFn
CMD
20h
21h
O/M
M
Supported
Yes
Get SDR Repository Info
Storage
Get SDR Repository Allocation Storage
Info
O
Yes
Reserve SDR Repository
Get SDR
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
Storage
22h
23h
24h
25h
26h
27h
28h
29h
2Ah
M
M
M
M
O
M
O
O
O
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
No
Add SDR
Partial ADD SDR
Delete SDR
Clear SDR Repository
Get SDR Repository Time
Set SDR Repository Time
Enter SDR Repository Update
Mode
Exit SDR Repository Update
Mode
Storage
Storage
2Bh
2Ch
O
O
No
Yes
Run Initialization Agent
Table 1-46. FRU Inventory Device Commands
Command
NetFn
CMD
10h
11h
12h
O/M
M
Supported
Yes
Get FRU Inventory Area Info
Read FRU Inventory Data
Write FRU Inventory Data
Storage
Storage
Storage
M
Yes
M
Yes
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-47. Sensory Device Commands
Command
NetFn
S/E
CMD
20h
21h
22h
23h
24h
25h
26h
27h
28h
29h
2Ah
2Bh
2Dh
2Eh
2Fh
30h
O/M
O
O
O
O
O
O
O
O
O
O
O
O
M
O
O
M
Supported
No
Get Device SDR Info
Get Device SDR
S/E
No
Reserve Device SDR Repository S/E
No
Get Sensor Reading Factors
Set Sensor Hysteresis
Get Sensor Hysteresis
Set Sensor Threshold
Get Sensor Threshold
Set Sensor Event Enable
Get Sensor Event Enable
Re-arm Sensor Events
Get Sensor Event Status
Get Sensor Reading
S/E
S/E
S/E
S/E
S/E
S/E
S/E
S/E
S/E
S/E
S/E
S/E
S/E
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Set Sensor Type
No
Get Sensor Type
No
Set Sensor Reading and Event
Status
Yes
Table 1-48. LAN Commands
Command
NetFn
CMD
O/M
Supported
Set LAN Configuration
Parameters
Transport 01h
M
Yes
Get LAN Configuration
Parameters
Transport 02h
M
Yes
Suspend BMC ARP
Transport 03h
Transport 04h
O
O
Yes
No
Get IP/UDP/RMCP Statistics
NOTE: LAN parameter from 192 to 255 is reserved for OEM parameters.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 1-48. LAN Commands
Command
NetFn
CMD
O/M
Supported
NOTE: Parameter 192 is used for DHCP Retry by DCS requirement.
Table 1-49. SOL Command
Command
NetFn
CMD
20h
O/M
O
Supported
No
SOL Activating
Transport
Set SOL Configuration Parameters Transport
21h
O
Yes
Get SOL Configuration
Parameters
Transport
22h
O
Yes
Table 1-50. PEF/PET Alerting Commands
Command
NetFn
S/E
CMD
10h
11h
12h
O/M
M
Supported
Yes
Get PEF Capabilities
Arm PEF Postpone Timer
S/E
M
Yes
Set PEF Configuration
Parameters
S/E
M
Yes
Get PEF Configuration
Parameters
S/E
13h
M
Yes
Set Last Processed Event ID
Get Last Processed Event ID
Alert Immediate
S/E
S/E
S/E
S/E
14h
15h
16h
17h
M
M
O
O
Yes
Yes
Yes
Yes
PET Acknowledge
58
Download from Www.Somanuals.com. All Manuals Search And Download.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
60
Download from Www.Somanuals.com. All Manuals Search And Download.
|