DO
Document # PG01 - 007
Revised 12/15/09 Page 1/2
PLANNING
GUIDE
Single, Distinctive
Wall Oven
Product tolerances: ±1/16” (±1.6 mm) unless otherwise stated
WARNiNG
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
•
•
Top of
chassis
L
This appliance must be installed in accordance with the
accompanying installation instructions.
B
Utility
cutout
J
F
G
H
C
D
A
MODEL DO130
¾” Conduit:
60” (152 cm)
long
21 1/8”
(53.7 cm)
K
Control panel
front
Top of
chassis
E
M
Chassis Notch
Side View
(E) Control
Panel
Overlay
B) Chassis (C) Overall (D)* Chassis
Width
Height
Height
4”
28 3/8”
28 7/16”
27 1/2”
15/16”
(6 cm)
(72.1 cm)
(72.4 cm)
(69.9 cm)
(2.4 cm)
* To top of chassis notch behind control panel
(F) Utility
(G) Utility
(H) Utility
(J) Control
Panel Depth
(K) Notch
Depth
(L) Chassis
(M) Notch
Height
Cutout Width Cutout Height Cutout Depth
Depth
5”
5 ¼”
6”
1”
1 5/8”
24”
1”
(12.7 cm)
(13.3 cm)
(15.2 cm)
(2.5 cm)
(4.1 cm)
(61.0 cm)
(2.5 cm)
Dedicated
Circuit
Requirements
Model
Number
Total Connected
Load
240 Vac 60 Hz.,
4-wire,**
DO130
5.3 kW (23 Amp.)
30 Amp.
** Two 120 Vac hot (L1 and L2), one neutral, one ground
The above specifications are for reference only. See the
appliance data plate for exact specifications.
Specifications subject to change without notice.
Install all appliances according to accompanying installation instructions.
Phone: (800) 793-0093