Curtis Marine Instruments 2100R User Manual

MODEL 2100R&  
2200R Engine Gages  
d from Www.Somanuals.com. All Manuals Search And Do  
Read Instructions Carefully !  
!
TABLE OF CONTENTS  
1. Safety Instructions  
2. Model Encodement  
Page  
2
3
!
!
3. Technical Specifications  
3.1 Electrical  
5
8
9
3.2 Mechanical  
3.3 Environmental  
4. Installation  
11  
14  
15  
5. Troubleshooting  
6. Maintenance  
d from Www.Somanuals.com. All Manuals Search And Do  
2. MODEL ENCODEMENT  
(for 2100R/2200R series)  
!
2111RXX-YYYY ZZ  
Model Numbers  
2111 Temperature  
2112 Fuel  
2113 Pressure  
2114 Voltage  
2211 Temperature/Hour  
2212 Fuel/Hour  
2213 Pressure/Hour  
2214 Voltage/Hour  
d from Www.Somanuals.com. All Manuals Search And Do  
3
!
R
= case (round)  
XX = voltage (DC voltages only)  
YYYY = sequential number code  
describes gage’s factory programming  
ZZ = artwork code (OO = Curtis)  
d from Www.Somanuals.com. All Manuals Search And Do  
4
3. TECHNICAL SPECIFICATIONS  
!
3.1 Electrical  
Operating Voltage  
Model Series 2100R and 2200R are available in either  
12VDC or 24VDC (negative ground systems only)  
Operating Voltages  
(Models 2111R, 2112R, 2113R and 2211R, 2212R, 2213R)  
Model  
12V  
Minimum  
9.0  
Nominal  
12.0  
Maximum  
16.0  
24V  
18.0  
24.0  
32.0  
(Models 2114R and 2214R)  
Model  
12V  
Minimum  
8.0  
Nominal  
12.0  
Maximum  
18.0  
24V  
16.0  
24.0  
36.0  
Accuracy  
Maximum indicator error is less than ±3.5% of full scale  
d from Www.Somanuals.com. All Manuals Search And Do  
5
Operating Current  
Total system current is a function of the voltage,  
sender type, display mode, and the gage’s factory  
programming. Typical operating currents (not  
including the current to drive the sender) vary from 16-55 mA,  
for 12V models, depending on model number. For 24V models,  
typical operating currents (not including the current to drive the  
sender) vary from 18-45 mA, depending on model number.  
!
Variable Parameters  
The following parameters are set in the factory as part of the  
gage’s programming. Contact Curtis for additional information  
on your specified model number.  
Sender input: Variable resistance  
Variable voltage  
Variable current  
Display mode  
Single LED pointer*  
Rising bar graph  
Transition points for each of the 10 LEDs  
(Used to customize display for OEM applications)  
*indicates standard setting  
d from Www.Somanuals.com. All Manuals Search And Do  
6
Output signal trigger point (lower)  
First LED  
Second LED  
Output signal trigger point (upper)  
Ninth LED  
!
Tenth LED  
Output signal format—(upper and lower independently set)  
0-5 V  
5-0 V*  
LED flashing mode (lower)  
No flashing  
First LED flashes alone  
First LED or second flashes alone  
Both first & second flash out of phase*  
LED flashing mode (upper)  
No flashing  
Tenth LED flashes alone  
Both tenth & ninth flash in phase  
Both tenth & ninth flash out of phase*  
*indicates standard setting  
d from Www.Somanuals.com. All Manuals Search And Do  
7
Damping and Hysteresis  
Transducer power modulation (XPM)  
Used to reduce current in sender circuit  
!
Output signal format  
Outputs are capable of sinking or sourcing up to 1mA,  
maximum (50µA maximum is standard)  
The 5V-0 output signal format is fully compatible with  
the Curtis Model 1178 relay module.  
3.2 Mechanical  
Terminals (Spade)  
Dimensions  
6 ANSI/NEMA 0.25 inch male fast-ons  
Bezel diameter  
Case diameter  
Depth  
58.8 mm, maximum  
51.5 mm, maximum  
45.0 mm, maximum  
(includes mounting studs)  
Weight  
70g, maximum  
Lens Material  
Case Material  
Glass (plastic lens optional)  
Black polycarbonate  
d from Www.Somanuals.com. All Manuals Search And Do  
8
Bezel Material  
Hardware  
Aluminum, black anodized  
U clamp (1)  
(Individually boxed 4 mm lock washers (2)  
units)  
Female 1/4 inch fast-on connectors (up to 6)  
4 mm knurled thumbnuts (2)  
U clamp (1)  
Hardware  
(OEM bulk packed) 4 mm lock washers (2)  
4 mm hex nuts (2)  
!
3.3 Environmental  
Temperature  
Operating  
Storage  
Shock  
-40C to +85C  
-50C to +90C  
Meets SAE J 1378 March 83.  
Amplitude 44-55g, half sine, 9-13 msec duration.  
d from Www.Somanuals.com. All Manuals Search And Do  
9
Vibration  
Humidity  
Meets SAE J 1378 March 83.  
!
Double amplitude of 1.53 mm with  
frequency sweep from 10-80-10 Hz  
(20 g max) at intervals of 1 minute.  
95% RH (non-condensing) at +38C  
Water/dust immunity  
Face  
Rear  
IP63  
IP50  
Salt spray (fog)  
ASTM B 117-73 as per SAE J1810, section  
4.7.1.2  
d from Www.Somanuals.com. All Manuals Search And Do  
10  
!
4.INSTALLATION  
Terminal  
Assignment  
for Models 2111R,  
2112R, 2113R  
1
2
3
4
5
6
Sender in  
Battery +  
Ground  
Sender low (optional: for use with two wire senders)  
Output signal (upper)  
Output signal (lower)  
d from Www.Somanuals.com. All Manuals Search And Do  
11  
Terminal Assignment for  
Model 2114R  
!
1
2
3
4
5
6
Not Connected **  
Battery +  
Ground  
Not Connected**  
Output signal (upper)  
Output signal (lower)  
Terminal Assignments for Models 2211R,  
2212R, 2213R  
1
2
3
4
5
6
Sender in  
Battery +  
Ground  
Hourmeter enable*  
Output signal (upper)  
Output signal (lower)  
d from Www.Somanuals.com. All Manuals Search And Do  
12  
Terminal Assignments for  
Model 2214R  
!
1
2
3
4
5
6
Not connected***  
Battery +  
Ground  
Hourmeter enable***  
Output signal (upper)  
Output signal (lower)  
* Options terminal can be factory programmed to function as  
hourmeter reset or sender low (for use with two wire senders)  
**Options terminal-can be factory programmed to measure a  
separate variable voltage supply.  
***Options terminals-can be factory programmed to measure a  
separate variable voltage supply. Hourmeter enable terminal  
could be factory programmed as an hourmeter reset.  
d from Www.Somanuals.com. All Manuals Search And Do  
13  
5. TROUBLESHOOTING  
The following checklist should help you to trou-  
!
bleshoot any problems with the instrument. Turning  
the instrument off and then on again after about 10  
seconds may solve the problem in the simplest cases.  
Make sure to observe the safety instructions in Section 1.  
Problem  
Possible Cause  
No display  
Voltage on Battery + terminal insufficient  
Display is not  
accurate  
Check sender installation. Teflon tape, some  
lubricants and anti-sieze compounds may  
prevent proper grounding of single wire  
senders. Check sender-to-gage wiring for  
excessive resistance.  
d from Www.Somanuals.com. All Manuals Search And Do  
14  
6. MAINTENANCE  
!
Curtis 2100R & 2200R Series Engine Gages are  
not serviceable in the field. Units returned to the  
factory within the warranty period will be replaced  
without charge.  
d from Www.Somanuals.com. All Manuals Search And Do  
16  
Guarantee - These Curtis Instruments’ products are guaran-  
teed against defects in workmanship and material for a period  
of three years, or as defined in the individual product literature,  
from date of shipment from our factory, when applied in a prop-  
er application within specified ratings. This guarantee is limited  
to repair or replacement F.O.B. our factory. There is no further  
warranty or implied representation, guarantee, promise or  
agreement as to any Curtis Instruments product and/or compo-  
nent. Curtis Instruments, Inc., cannot assume responsibility or  
accept invoices for unauthorized repairs to its products and/or  
components, even though defective. In no case will Curtis  
Instruments’ responsibility extend to products, components  
or equipment not of its manufacture. Under no circumstances  
shall Curtis Instruments, Inc., be liable for any special or  
consequential damages or loss of profits or other damages.  
Returned goods will not be accepted unless identified by a  
Curtis Return Material Authorization (RMA).  
All specifications are subject to change  
without notice.  
d from Www.Somanuals.com. All Manuals Search And Do  
CURTIS INSTRUMENTS, INC.  
200 Kisco Avenue, Mt. Kisco, NY 10549  
Tel. (914) 666-2971 • FAX (914) 666-2188  
53018 REV A 10/97  
d from Www.Somanuals.com. All Manuals Search And Do  

Contax Film Camera RTS III User Manual
Cooper Lighting Indoor Furnishings CLM Square User Manual
Cooper Lighting Marine Safety Devices HR87C User Manual
Cuisinart Kitchen Grill PG 29365 User Manual
Delta Electronics Power Supply SIQ127RL User Manual
Ducane HVAC Air Conditioner EC1P User Manual
Dynex CRT Television DX R13TV User Manual
Dyson Vacuum Cleaner 13729571 User Manual
Elation Professional Work Light Opti Tri Par User Manual
GE Dishwasher GHD5015 User Manual