| SERVICE MANUAL   (DOMESTIC)   IMPINGER CONVEYOR OVENS   MODEL 1450,1451   WITH PUSH BUTTON CONTROLS   Lincoln Foodservice Products, Inc.   1111 North Hadley Road   P.O. Box 1229   Fort Wayne, Indiana 46801-1229   Phone: (800) 374-3004 • Fax: (260) 436-0735   Technical Service Hot Line   (800) 678-9511   1450digservice   REV 12/6/05   Download from Www.Somanuals.com. All Manuals Search And Download.   SCHEMATIC DIAGRAM   MODEL 1450, 1451   SERIAL NUMBER N28654 AND ABOVE   Impinger I – 1450 Series Service Manual - Domestic   3 Download from Www.Somanuals.com. All Manuals Search And Download.   TROUBLESHOOTING GUIDE   IMPINGER ADVANTAGE GAS OVENS   SERIAL NUMBER N28654 AND ABOVE   (OVENS WITH PUSH BUTTON CONTROLS)   SYMPTOM   Oven fan will not run   POSSIBLE CAUSE   Incoming power supply   EVALUATION   Check circuit breaker, reset if required. Check power   plug to be sure it is firmly in receptacle. Measure   incoming power, call power co. if needed.   Check, replace if necessary.   Fuse, 10 Amp   Fuse holder   Check, replace if necessary.   Switch, oven power   Check for 120VAC supply to switch. If no voltage is   present, trace wiring back to fuse holder. Check   continuity between switch terminals. Replace switch as   needed.   Motor, main fan   Check for 120VAC supply to the motor. If no voltage is   present, trace wiring back to the switch. Check motor   for opens, shorts or grounds.   WITH POWER OFF: Turn fan blade to check for locked   rotor.   No control box cooling Incoming power supply   Check circuit breaker, reset if required. Check power   plug to be sure it is firmly in receptacle. Measure   incoming power, call power co. if needed.   Check, replace if necessary.   Fuse, 10 Amp   Fuse holder   Check, replace if necessary.   Switch, oven power   Check for 120VAC supply to switch. If no voltage is   present, trace wiring back to fuse holder. Check   continuity between switch terminals. Replace switch as   needed.   Cooling fan   Check for 120VAC supply to the cooling fan. If no   voltage is present, trace wiring back to the oven power   switch. If voltage is present and motor does not run,   check for opens, shorts or grounds.   WITH POWER OFF: Check for locked rotor.   Check circuit breaker, reset if required. Check power   plug to be sure it is firmly in receptacle. Measure   incoming power. Call power co. if needed.   Check cooling fan thermostat (thermostat closes at   120°F and opens at 100°F). With cooling fan   thermostat pre-heated, check for continuity. If   thermostat is open, replace cooling fan thermostat.   See “Cooling fan thermostat” (NOTE: Thermostat will   remain closed if control box temperature remains   above 120°F.   No automatic control   box cooling   Incoming power supply   Cooling fan thermostat   Control box cooling   fan continues to run   Cooling fan thermostat   Oven will not heat   Main fan   Gas supply   If not operating, refer to “Oven fan will not run”.   Check for adequate gas supply to oven.   Centrifugal switch of main fan Check for 120VAC at wire #5 (input to centrifugal   motor   switch, located at 6-pin connector inside motor cover   near main fan motor) to neutral. If no voltage is present,   trace wiring back to oven power switch. If voltage is   present, check for 120VAC at wire #9 (output of   centrifugal switch) to neutral. If no voltage is present at   wire #9, and the motor is running, replace the main fan   motor.   Burner blower motor   Check for 120VAC supplied to burner blower motor. If   no voltage is present, trace wiring back to primary of   control transformer. If voltage is present and motor is   4 Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   not running, check for opens, shorts or grounds.   WITH POWER OFF: Turn motor to check for locked   rotor. Replace burner blower motor as needed.   Check for 120VAC supplied to primary of burner   transformer. If no voltage is present, trace wiring back   to centrifugal switch of main fan motor. If voltage is   present, check for 24VAC supply at transformer   secondary. If there is primary voltage but no secondary   voltage, replace burner transformer.   Check for 24VAC at motor connector, wire #19 (input to   centrifugal switch) to neutral. If no voltage is present,   trace wiring back to burner transformer. If voltage is   present, check for 24VAC at wire #20 (output of   centrifugal switch) to neutral. If no voltage is present at   wire #20 and motor is running, replace burner blower   motor.   Burner transformer   Centrifugal switch of burner   blower motor   Ignition control   Check for 24VAC supply to the ignition control. If no   voltage is present, trace wiring back to centrifugal   switch of burner blower motor. If voltage is present,   check for 24VAC at pin #3 and ground (pilot valve).   NOTE: The Honeywell ignition control has a 30 second   pre-purge (time delay) built in. If voltage is not present,   replace ignition control. If the pilot valve is energized,   check to see that the high voltage igniter circuit is also   energized. To check, disconnect the igniter lead from   the ignition control.   No pilot flame   If the ignition control is supplied with 24Vac and the   pilot valve (internal to valve assembly) and igniter   circuits are energized, visually check for pilot flame.   This may be done by opening the small inspection door   on the end of the burner, or by opening the main oven   door and looking under the lower finger housings on   the right side of the oven. If no pilot flame is visible,   check the pilot shut-off valve.   Pilot shut-off valve   Pilot tube   Check to see that the pilot shut-off valve is open (shut-   off valve is located between valve assembly and   burner).   Check for gas pressure at the pilot tube. Disconnect   pilot tube at burner and connect a manometer to pilot   tube. If no gas pressure is present during ignition,   check for blockage in pilot tube or pilot shut-off valve. If   these are clear, and there is gas supplied to the oven,   replace the gas valve.   Pilot orifice   If there is gas pressure at the pilot tube, check the pilot   orifice for obstructions. Replace as needed.   Check the burner igniter head for any obstructions, also   check for frayed or broken wire. Check spark gap (gap   should be .100 to .125 inch). If there is visible damage,   replace burner igniter.   Burner igniter   NOTE: Flame should be on   at this time   Control transformer   Pilot flame, but no   main flame   Check for 120VAC supply to the primary of the control   transformer. If no voltage is present, trace wiring back   to the oven power switch. If voltage is present, check   foe 24VAC at the transformer secondary. If there is   primary voltage, but no secondary voltage, replace   control transformer.   Oven control   Check for 24VAC supply to oven control. If no voltage   is present, trace wiring back to control transformer. If   24VAC is present, check for a read-out on the display.   If there is 24VAC supplied, but there is no read-out on   5 Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   the display, replace oven control. If there is a read-out   on the control, set the control to maximum temperature   (see Installation operations manual for temperature   adjustment). With the control set at maximum   temperature, check for 120VAC at the temperature   regulation valve. If there is voltage at the temperature   regulation valve, proceed to “Temperature regulation   valve” for next check. If there is no voltage at the   temperature regulation valve, trace wiring back to the   oven control. If there is no voltage output at the oven   control, check the read-out on the oven control. If the   control reads “PROBE FAIL”, this indicates that the   thermocouple has failed or become disconnected from   the oven control.   Check to be sure that the thermocouple is securely   connected to the oven control. If the thermocouple is   connected to the oven control, and the control indicates   “PROBE FAIL”, disconnect the thermocouple from the   oven control and measure the resistance of the   thermocouple. The thermocouple should read approx.   11Ω. If these readings are not achieved, replace the   thermocouple. If these readings are correct, proceed.   If the thermocouple checks good, but the oven control   display indicates that there is a thermocouple failure,   replace the oven control. If the oven control indicates a   temperature reading, but the oven will not heat,   proceed.   Thermocouple   Oven control   Thermocouple   WITH POWER ON AND THERMOCOUPLE   ATTACHED TO THE OVEN CONTROL: Measure the   DC millivolt output of the thermocouple. Refer to the   thermocouple chart (located in the “Removal” section of   the manual) for proper millivolt readings. If these   readings are not achieved, replace thermocouple.   If the thermocouple checks good, but there is no   120VAC output to the temperature regulation valve,   replace the oven control. If there is 120VAC output to   the temperature regulation valve, proceed.   Oven control   Temperature regulation valve Check for 120VAC supplied to the temperature   regulation valve. If voltage is present, listen for valve to   open and close. Also check for opens or shorts in the   operating coil. Replace temperature regulation valve as   needed.   Intermittent heating   Thermal/overload of main fan The main fan motor and burner blower motor are   and burner blower motors   equipped with internal thermal protection and will cease   to operate if overheating occurs. As the motors   overheat and then cool, this will cause the heating   system to cycle on and off intermittently. Improper   ventilation or lack of preventive maintenance may   cause this problem. Also, most of the problems listed   under “Oven will not heat” can cause intermittent   failure.   Conveyor will not run   Incoming power supply   Check circuit breaker, reset if required. Check power   plug to be sure it is firmly in receptacle. Measure   incoming power, call power co. if needed.   Check, replace if necessary.   Fuse, 10 Amp   Fuse holder   Check, replace if necessary.   Switch, oven power   Check for 120VAC supply to switch. If no voltage is   present, trace wiring back to fuse holder. Check   continuity between switch terminals. Replace switch as   needed.   6 Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   Control transformer   Conveyor motor   Check for 120VAC supply to the primary of the control   transformer. If no voltage is present, trace wiring back   to the oven power switch. If voltage is present, check   foe 24VAC at the transformer secondary. If there is   primary voltage, but no secondary voltage, replace   control transformer.   Check for 120VAC supply to conveyor motor at wire #6   to neutral. If no voltage is present, trace wiring back to   oven power switch. If voltage is present and motor will   not run, check the motor windings for opens or shorts.   WITH POWER OFF: Check the motor windings as   follows:   Grey to black - 38Ω approx.   Grey to blue - 38Ω approx.   Blue to black - 75Ω approx.   If any of the above fails, replace conveyor motor.   Check for shorts or grounds. Replace capacitor as   needed.   Capacitor, conveyor motor   WARNING: Capacitor has a stored charge, discharge   before testing.   Check continuity between switch terminals. Replace as   needed.   If there is 120VAC supplied to the motor, and the   motor, capacitor, and reversing switch check good,   replace the oven control.   Switch, conveyor reversing   Oven control   Conveyor motor runs,   but there is no speed   display   NOTE: Display will indicate   “BELT JAM”   Oven control   Conveyor motor   Oven control   Check for output voltage from oven control to hall effect   sensor (sensor is located in conveyor motor). Measure   voltage at the motor connector, red wire and yellow   wire. Voltage should be approx. 10VDC. If no voltage is   present, trace wiring back to oven control. If there is no   voltage present at the oven control, replace the oven   control.   If there is voltage supplied to the hall effect sensor,   check for a frequency output from the hall effect   sensor. Measure frequency across the yellow and white   wires at the motor connector. Frequency reading   should be approx. 25 – 100 Hz. If these readings are   not achieved, replace conveyor motor. If these readings   are achieved, proceed.   If the hall effect sensor readings are correct, but there   is no speed indicated on the display, replace the oven   control.   Impinger I – 1450 Series Service Manual - Domestic   7 Download from Www.Somanuals.com. All Manuals Search And Download.   REMOVAL, INSTALLATION & ADJUSTMENTS   IMPINGER ADVANTAGE SERIES   CAUTION!   BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER   OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY   MOTOR, MAIN FAN - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut off power at main breaker.   Remove louvered motor cover from back of oven.   Remove wireway by taking out the (5) five hex screws.   Disconnect wiring from motor.   Remove the twelve (12) hex head bolts from the oven back and slide back straight out of the oven.   Remove two (2) bolts from fan hub and remove fan from motor shaft.   NOTE: Measure distance from fan blade to rear wall assembly before removal to aid in reassembly.   Remove the eight (8) hex head bolts from the motor mount and slide the motor assembly out of the oven   back.   7.   8.   9.   Remove motor by taking off motor clamp and removing the four (4) mounting nuts and washers.   Reassemble in reverse order. When motor mount assembly is set on the oven back, align motor shaft in   the center of the hole. Set fan assembly on the motor shaft.   NOTE: A. Torque specs on bolts (150 in/lb. torque)   B. It is recommended that an anti-seize compound be brushed on to the bolts around the back   and motor mount bracket before assembly.   FAN, MAIN - REPLACEMENT   1.   2.   3.   Shut off power at main breaker.   Remove back assembly. (See MOTOR, MAIN FAN)   Reinstall and locate fan so that the bottom of the fan spider is 1 1/2" from the top of the oven back cone.   (See Drawing)   FAN SPIDER   NOTE: MEASUREMENT MUST BE   MADE FROM CONE TO FAN SPIDER   FAN HUB   CONE   1 1/2 INCH   CAPACITOR, MOTOR - REPLACEMENT   1.   2.   3.   4.   Shut off power at main breaker.   Remove motor cover from back of oven.   Discharge capacitor.   Remove and replace.   COOLING FAN, CONTROL BOX - REPLACEMENT   1.   2.   3.   4.   5.   Shut off power at main breaker.   Remove control panel top and front cover.   Remove four (4) screws from the fan frame.   Disconnect cord and plug and remove fan.   Reassemble in reverse order.   8 Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   THERMOSTAT, COOLING FAN - REPLACEMENT   1.   2.   3.   4.   5.   Shut off power at main breaker.   Remove control panel top and front cover.   Remove lead wires and mark for reassembly.   Remove two (2) screws and remove thermostat.   Reassemble in reverse order.   BURNER BLOWER MOTOR - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut off power at main breaker.   Remove control panel top and front cover.   Unplug motor connector.   Remove three (3) screws from blower tube at burner housing.   Remove air shutter assembly from old motor for installation on new motor assembly.   Reassemble in reverse order and check system operation.   NOTE: Check air shutter adjustment and adjust if necessary. Set air shutter at approx. 1/4" and adjust   to get a blue flame with an occasional tip of yellow under high flame. A view port in the burner assembly   should be used to observe flame.   BLOWER WHEEL, BURNER   This is part of the burner blower motor assembly.   TO REMOVE THE BLOWER WHEEL FOR PERIODIC CLEANING:   1.   2.   3.   4.   5.   Shut off power at main breaker.   Remove control panel top and front cover.   Remove air shutter held by 3 screws.   Loosen set screws on blower wheel hub and pull straight out.   Reassemble in reverse order.   NOTE: There is no critical placement of the blower wheel on the motor shaft. Just back as far as   it will go and then spin the blower to be sure it is not rubbing.   BURNER CONTROL - REPLACEMENT   1.   2.   3.   4.   5.   Shut off power at main breaker.   Remove control panel top and front cover.   Remove wires from control, note wire numbers and location for reassembly.   Remove Two (2) screws from control and replace.   Reassemble in reverse order and check system operation.   BURNER ASSEMBLY   1.   2.   3.   4.   5.   6.   7.   8.   Shut off power at main breaker.   Shut off gas supply.   Remove control panel top and front panel.   Remove gas control valve (See "GAS CONTROL VALVE")   Disconnect pilot tube.   Remove solenoid valve. (See "TEMPERATURE REGULATION VALVE")   Remove four (4) screws that secure the burner backing plate.   Remove burner assembly from housing, the main and pilot orifice, flame target, pilot shield (main and   extension), burner ignitor can now be changed or serviced as needed.   Reassemble in reverse order. Check all gas line fittings for leaks.   9.   GAS CONTROL VALVE - REPLACEMENT   1.   2.   3.   4.   5.   Shut off power at main breaker.   Shut off gas supply.   Remove control panel top and front cover.   Disconnect the gas piping from the back of the unit.   Remove the four(4) screws from the incoming nipple mounting bracket.   Impinger I – 1450 Series Service Manual - Domestic   9 Download from Www.Somanuals.com. All Manuals Search And Download.   6.   7.   8.   9.   Remove incoming nipple.   Remove pilot tube assembly from control valve.   Disconnect pipe union just above solenoid valve.   Disconnect wiring from control valve making note of wire numbers and location. Remove piping from old   valve for installation on new valve.   10. Reassemble in reverse order - after assembly is complete, be sure to check manifold pressure   (3.5" W.C. NAT GAS 10" W.C. LP) and adjust if necessary. (See Section "MANIFOLD PRESSURE -   ADJUSTMENT")   NOTE: Check all gas line fittings for leaks after installation.   MANIFOLD ADJUSTMENT   SCREW LOCATED UNDER   COVER SCREW   FRONT VIEW   MANIFOLD PRESSURE   ADJUSTMENT CONNECTION   PILOT   LINE   CONNECTION   MANIFOLD ADJUSTMENT   SCREW LOCATED UNDER   COVER SCREW   TOP VIEW   MANIFOLD PRESSURE - ADJUSTMENT   1.   2.   Remove control panel top and front cover.   WITH ELECTRIC POWER AND GAS OFF: Remove the outlet pressure tap plug from the gas control   valve and install the adapter fitting and manometer.   3.   4.   Turn on electric power and gas and start-up oven.   With oven at full fire, manifold pressure should be (3.5" W.C. NAT/ 10" W.C. LP). If adjustment is   needed, remove cover screw from valve body and adjust by turning regulator screw. (C.W. to increase,   C.C.W. to decrease).   5.   Turn off electric power and gas, replace cover screw, remove manometer and adapter; Replace   pressure tap plug.   Check pressure tap for gas leaks before closing panel.   Close control panel and check system operation.   6.   7.   TEMPERATURE REGULATION VALVE - REPLACEMENT   1.   2.   3.   4.   5.   6.   7.   8.   9.   Shut off power at main breaker.   Shut off gas supply.   Remove control panel top and front cover.   Remove gas control valve (See "GAS CONTROL VALVE")   Disconnect wires from temperature regulation valve.   Remove two (2) hex nuts that hold main orifice bracket in place.   Remove temperature regulation valve assembly.   Remove piping from temperature regulation valve.   Reassemble in reverse order.   10. Check all fittings for leaks.   10   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   BURNER IGNITOR - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut off power at main breaker.   Remove control panel top and front cover.   Remove burner assembly. (SEE "BURNER ASSY.")   Remove pilot shield and pilot shield extension.   Remove burner ignitor.   Reassemble in reverse order (spark gap approx. .100 in. or 2.5 mm)   NOTE: Be sure to reconnect burner ignitor cable to ignition control.   THERMOCOUPLE - REPLACEMENT   1.   2.   3.   Shut off power at main breaker.   Remove control panel top and front cover.   Slide thermocouple out of oven chamber.   NOTE: Remove conveyor and bottom fingers to aid in removal and installation of thermocouple.   Remove two (2) wires from temperature control. Make note of wire numbers or color and location for   reinstallation.   4.   5.   Reassemble in reverse order making sure the metal end on the thermocouple is in the wire form in the   oven chamber.   THERMOCOUPLE MEASURMENT   TEMPERATURE   200°   D.C. MILLVOLTS (APPROX.)   2.8   4.0   5.1   6.0   7.1   8.2   9.3   10.4   11.5   250°   300°   350°   400°   450°   500°   550°   600°   BURNER CONTROL TRANSFORMER - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut power off at main breaker.   Remove control panel top and front cover.   Remove two (2) wires on primary side, note color and location.   Remove two (2) wires on secondary side, note color and location.   Remove two (2) screws from transformer base and replace assembly.   Reinstall in reverse order and check system operation.   CONTROL TRANSFORMER – REPLACEMENT   See “BURNER CONTROL TRANSFORMER – REPLACEMENT”   CONVEYOR DRIVE MOTOR - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut power off at main breaker.   Remove control panel top and front cover.   Loosen set screw on conveyor drive sprocket and slide sprocket off shaft.   Disconnect motor plug.   Remove four (4) screws from motor frame, on control box side, and remove motor assembly.   Reassemble in reverse order making sure to align chain sprockets and adjust motor for proper chain   tension (1/2" SAG).   Impinger I – 1450 Series Service Manual - Domestic   11   Download from Www.Somanuals.com. All Manuals Search And Download.   REVERSING CONVEYOR DIRECTION   All ovens leaving our plant are wired to operate conveyors from left to right. To reverse conveyor direction, use   the following procedure.   1.   2.   3.   Shut off power at oven switch.   Set conveyor reversing switch in the other position.   Turn oven “on” and check for proper operation.   MAIN ORIFICE - REPLACEMENT   1.   2.   3.   4.   5.   6.   7.   Shut off power at main breaker.   Remove control panel top and front panel.   Remove gas control valve assy.   Remove two (2) nuts from burner orifice bracket.   Disconnect pipe union.   Remove assembly and replace main orifice.   Reassemble in reverse order and check system operation. NOTE: Check all gas line fittings for leaks.   PILOT ORIFICE - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut off power at main breaker.   Shut off gas supply.   Remove burner assembly (See "Burner Assembly").   Remove pilot line from pilot orifice.   Remove pilot orifice from burner ignitor.   Reassemble in reverse order. NOTE: Check all gas line fittings for leaks.   ON-OFF SWITCH - REPLACEMENT   1.   2.   3.   4.   5.   6.   Shut off power at main breaker.   Remove control box cover.   Remove access cover.   Depress spring clips on side of switch and push out.   Remove wires from back of switch, note wire number and location.   Reassemble in reverse order and check system operation.   NOTE: Make sure switch housing is fully seated in control box housing.   OVEN CONTROL – REPLACEMENT   A.   B.   C.   D.   E.   Shut off power at main breaker.   Remove control box cover and front panel.   Remove all wiring connections and mark for reassembly.   Remove oven control by pulling control from the mounting pins. Remove control from oven.   Before installing new oven control, set voltage jumper (located at the bottom center of the oven   control) to the proper voltage (120V/240V) position. Install the four pushbutton extensions   (included with the oven control) by pushing the extensions onto the four set buttons on control.   Reassemble in reverse order and check system operation.   F.   G.   Set the oven control for the proper operating mode. The 1400 series ovens use a single temperature   control system. The oven control must be set to the proper operating mode. Set the control as follows:   With the oven power switch “off”, depress the “time” and “up” buttons and turn the oven “on”. Control   will indicate “Imp I or Imp II” Release the buttons, The control will indicate “Temp to store”. Press the   “up” or “down” button until “Imp I” appears on the display. Press the “temp” button. The control is now   set for single burner operation.   FUSE HOLDER – REPLACEMENT   1.   2.   3.   4.   5.   Shut off power at main breaker.   Remove control box cover.   Remove all wiring from fuse holder and mark for reassembly.   Remove mounting nut for fuse holder and remove fuse holder.   Reassemble in reverse order and check system operation.   12   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   This page intentionally left blank.   Impinger I – 1450 Series Service Manual - Domestic   13   Download from Www.Somanuals.com. All Manuals Search And Download.   GENERAL VIEW   ADVANTAGE SERIES   LETTER   PART NUMBER   DESCRIPTION   Door hinge   Access window assembly   Retainer (old style)   Retainer (new style)   Handle spacer   A B C 369003   369110   369337   369929   369828   369209   369310   369308   369334   369309   350638   369311   369336   369906   370110   369157   1534   D E F G H J K L M N O P Q R S T Latch & strike   Screw, 6-32 x 3/16”   Bottom, access window   Access door glass   Top, access window   Handle   Handle spacer (2 req.)   Door latch   Screw, 8-32 x 5/8”   Door assembly (solid)   Door assembly (with window)   Finger support assembly   Support bracket pin   Strike assembly   369057   369643   1009   Oven top   U V W X Y Z * AA   BB   CC   DD   EE   FF   GG   HH   JJ   KK   LL   369062   369140   369903   369141   369139   369058   369211   369203   369749   369204   369373   369748   369328   369052   369030   369904   369053   Top, control box   Compression spring   Washer, flat   Conveyor hold down bracket   Shoulder screw   Baffle, inlet and outlet   Thumb screw (not shown)   Stud, wing head   Chain cover kit (includes AA, CC)   Split ring retainer   Receptacle, snap –in   Bracket, chain cover   Leg, stand   Adjustable leg   Caster, 6”   Insulation holder assembly   Finger housing   Columnating plates –   see installation operations manual   Finger cover   Crumb pan, internal   Window frame, bottom   Glass, access window   Window frame, top   MM   NN   OO   PP   369055   369218   369926   369925   369927   QQ   14   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   Impinger I – 1450 Series Service Manual - Domestic   15   Download from Www.Somanuals.com. All Manuals Search And Download.   CONTROL BOX – 1450, 1451   S/N N28654 and ABOVE   LETTER   PART #   369263   369344   369398   370059   369072   369099   369144   369202   369076   369075   369142   369366   369399   369400   370362   370368   369158   369124   369393   370359   369507   369331   369531   370352   370418   370355   370354   369805   370363   369537   369129   369166   353014   DESCRIPTION   Gas Valve   A B C D E Pilot Shut Off Valve   Solenoid Valve Nat/LP   Manifold, Burner   Main Orifice, Nat.   Main Orifice, L.P.   Pilot Shield Extension   Pilot Shield, Main   Burner Igniter   F G H I J K L M N O P Q R S T U V W Y Flame Sensor   Flame Target   Burner Blower Motor   Air Shutter   Plate, Air Shutter   Thermocouple, Type K   Conveyor Motor   Sprocket, Drive   Cooling Fan   Ignition Control   Reversing Switch   Control Box Thermostat   Finger Guard, Cooling Fan   Transformer, 24 VAC   Capacitor, Conveyor motor   Top, Control Box   Control, Oven   Facia, Front   Switch, On-Off   Front Cover   Power Cord   Fuse Holder   Fuse, 10 A   Ground Lug   Z AA   BB   CC   DD   EE   FF   GG   16   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   Impinger I – 1450 Series Service Manual - Domestic   17   Download from Www.Somanuals.com. All Manuals Search And Download.   OVEN BACK   ADVANTAGE SERIES   GAS AND ELECTRIC   LETTER   A PART NUMBER   DESCRIPTION   369808   370140   369800   369214   369033   369215   369192   369306   369646   369647   369213   369547   369287   369315   369122   Cover, motor (gas ovens)   Cover, motor (electric ovens)   Motor, main fan (60 Hz.)   Motor, main fan (50 Hz.)   Motor clamp   Motor support assembly   Capacitor, 7.5 MFD   Oven back assembly, gas oven   Stand-off   Inlet panel   Main fan   Bracket, thermostat   Heating element, 208V   Heating element, 220V   Heating element, 240V   B C D E F G H J K M 18   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   Impinger I – 1450 Series Service Manual - Domestic   19   Download from Www.Somanuals.com. All Manuals Search And Download.   CONVEYOR   1450 SERIES   LETTER   A PART NUMBER   DESCRIPTION   Complete conveyor assembly   Conveyor belt   Conveyor belt, 1 foot section   Retaining ring   Conveyor bearing block   Roll, conveyor, notched   Conveyor idler shaft   Conveyor pan stop   Connecting link   Conveyor drive shaft   Roller chain sprocket   Crumb pan   Conveyor frame   Drive chain   369830   369816   370092   369825   369813   369314   369812   369160   369814   369811   369161   369806   370050   369162   B C D E F G H J K L M 20   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   Impinger I – 1450 Series Service Manual - Domestic   21   Download from Www.Somanuals.com. All Manuals Search And Download.   22   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   Impinger I – 1450 Series Service Manual - Domestic   23   Download from Www.Somanuals.com. All Manuals Search And Download.   24   Impinger I – 1450 Series Service Manual - Domestic   Download from Www.Somanuals.com. All Manuals Search And Download.   |