Crown Boiler Burner CHB68 112L User Manual

Instructions for Installation and  
Connection of Oil Burner to Furnace  
For Furnace Models:  
CHB68-112L  
CHC68-96L  
CLBF68-112L  
CLBR68-112L  
: Failure to follow these instructions exactly may result in a fire or  
explosion causing property damage, personal injury or loss of life.  
DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of  
this or any other appliance.  
What to do if you find an oil leak:  
DO NOT try to operate this appliance.  
If possible, close the manual fuel shutoff valve on the oil supply tank.  
Immediately call your oil supplier. Follow the oil supplier’s instructions.  
If you cannot reach your oil supplier, call the fire department.  
A qualified installer, service agency, or the oil supplier must perform installation and  
service.  
These instructions should be:  
read prior to installation.  
retained for qualified service personnel  
reviewed before performing any service or maintenance.  
Crown Boiler Company  
3633 “I” Street  
Philadelphia, Pennsylvania 19134  
MO-432  
ECN4514-MA  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Only qualified service personnel shall perform installation and service.  
1) Remove the oil burner from the shipping carton and remove any shipping  
materials adhering to the burner. Collect and save the burner mounting gasket  
and any instructions furnished with the burner.  
2) If it is necessary to adjust the heating capacity of the furnace, by changing the oil  
burner nozzle, refer to the following directions.  
a) The oil nozzle is factory installed in the oil burner. To change the oil nozzle,  
remove the nozzle through the front end of the burner air tube. Consult the oil  
burner manufacturer’s operating instructions (included with the burner) for  
detailed instructions on this procedure.  
b) Install an appropriate replacement nozzle of the correct size, spray angle,  
and spray type. Refer to the Specification Sheets, in Appendix C of the  
furnace instruction manual, for nozzle recommendations.  
3) On highboy furnace models, remove the burner access panel. This panel will be  
the upper access panel on the front of the furnace. On lowboy models, remove  
the front access panel. On horizontal / counterflow models, the burner is  
mounted on the front surface of the furnace.  
4) Remove the three (3), 5/16 in. brass hex machine screw nuts and the three (3)  
steel flat washers from the threaded studs protruding through the burner  
mounting plate on the furnace. Retain this hardware for later reuse.  
5) Rough handling of the furnace may occur while in transit. Under some  
conditions, the combustion chamber can shift out of position. The chamber  
should seat properly on the base of the heat exchanger. Check for proper  
alignment of the burner air tube with the circular opening in the combustion  
chamber and trial fit the burner to check the insertion depth of the oil burner into  
the combustion chamber. It may be necessary to remove the burner mounting  
plate to get sufficient access to the chamber.  
The end of the burner air tube should be inserted no farther than 1/4 inch  
back from the inside surface of the combustion chamber, refer to Figure 1.  
DO NOT allow the burner head, at the end of the burner air tube, to physically  
touch or protrude into the chamber. High temperatures in the combustion  
chamber can result in damage to the tube, the burner head, or both. A distance  
greater than 1/4 inch back from the inside chamber wall may cause oil spray  
impingement on the combustion chamber wall and subsequent sooting and the  
formation of carbon char deposits.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Only qualified service personnel shall perform installation and service.  
Figure 1: Side View of Correct Burner Insertion into Combustion Chamber  
6) Reinstall the burner mounting plate, if removed, and push the burner flange  
gasket (included with the burner) on to the burner mounting plate threaded studs.  
Seat the gasket against the mounting plate.  
7) Reusing the fasteners removed in step (4) [three (3), 5/16 in. brass hex nuts and  
three (3) steel flat washers], install and secure the burner to the mounting studs  
protruding through the burner mounting plate, refer to Figure 2. (For counterflow /  
horizontal units, refer to the section of the furnace instruction manual entitled  
“Horizontal / Counterflow Furnace Setup”)  
Figure 2: Installing and Securing the Oil Burner to the Furnace Mounting Plate  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Only qualified service personnel shall perform installation and service.  
8) The burner and wiring harness are equipped with mating, three (3) pole, quick-  
connect, electrical couplings. To make the connection between the burner wiring  
harness and the furnace wiring harness, open the burner junction box cover (the  
oil primary control serves as the cover) and remove a knockout slug from the  
right-hand side of the burner junction box.  
9) Insert the electrical coupling from the furnace wiring harness through the  
knockout hole in the burner junction box. Snap together the furnace electrical  
coupling with the oil burner electrical coupling, refer to Figure 3.  
Figure 3: Connecting the Furnace Wiring Harness to the Burner Wiring Harness  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Only qualified service personnel shall perform installation and service.  
NOTICE: On the horizontal / counterflow furnace wiring harness, remove  
the lock-ring from the end of the flexible metal conduit connector BEFORE  
connecting the electrical couplings.  
10)On the highboy and lowboy furnace wiring harnesses, snap the strain relief fitting  
into the knockout opening in the burner junction box. On the horizontal /  
counterflow furnace wiring harness, insert the conduit fitting through the  
knockout opening in the burner junction box and thread on the lock-ring from the  
inside of the junction box. Tighten the lock-ring until it is snug.  
11)Close and secure the junction box cover on the burner.  
The oil burner provided with this furnace requires additional installation, set-up, and  
proper adjustment. Refer to the furnace instruction manual and the oil burner  
manufacturer’s operating instructions for detailed information on the following items.  
Completion of fuel line connections to burner  
Initial firing of burner  
Adjusting the fuel pump pressure  
Setting the draft control  
Adjusting the burner combustion air  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Clarion Car Video System NX702 User Manual
Craftsman Lawn Mower 37624 User Manual
Crown Audio Stereo Amplifier 12000i User Manual
DigiTech Musical Toy Instrument Whammy Ricochet User Manual
Dixon Lawn Mower Accessory 3302 User Manual
Fisher Price Baby Toy 73455 User Manual
Fisher Price Motorized Toy Car T5003 User Manual
Fitness Quest Home Gym 1100HR User Manual
Frigidaire Washer FAFW3577KA1 User Manual
Gefen Cable Box EXT DVI 141B User Manual